Provide protection even when electricity fails, provided the batteries are fresh
Can be interconnected so if one unit senses smoke, all units alarm. They do not operate
Can be interconnected so if one unit senses smoke,
all units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be
AC powered unit that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in
All these units are designed to provide early warning of fires if located, installed and cared for as described in the user’s
manual, and if smoke reaches them. If you are unsure which type of unit to install, refer to Chapter 2 of the National Fire
This smoke alarm alone is not a suitable substitute for complete fire detection systems in places housing many people—like
apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, nursing homes,
day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a suitable substitute for
residential buildings which require special fire detection and alarm systems. Depending on the building codes in your area,
In new construction, most building
or DC powered smoke alarms can be used as specified by local building codes. Refer to NFPA 72 (National Fire Alarm
Code) or NFPA 101 (Life Safety Code) local building codes, or consult your Fire Department for detailed fire protection
Apartment building, condominium. This type of unit is suitable for use
individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection
sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in
Smoke alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning
device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them.
power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or
Smoke from fires in chimneys or walls, on
unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed
For example, a stand-alone unit on the
installing interconnected AC powered units with battery back-up (see “Other Features Of Smoke Alarms”) or professional
Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if
Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire
Single family home, townhouse. It is recommended smoke alarms be installed on every
common areas like lobbies, hallways, or porches. Using this type of unit in common areas may not provide sufficient
roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one
second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to
fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning
Special purpose smoke alarms should be installed for the hearing
They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With
requirements in common areas like lobbies, hallways, or porches. Using this type of unit in common areas may not
requirements in common areas like lobbies, hallways, or porches. Using this type of unit in common areas may not
disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units
cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a
escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every
Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require
in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection
bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much
smoke alarm model SA100B is an
complete fire detection systems in warehouses, industrial facilities, commercial buildings, and special-purpose non-
Hospitals, day care facilities, long-term health care facilities. This type of unit is suitable for use in
Also boarding houses and dormitories.This type of unit is suitable for use inside individual
Battery operated units cannot work if the batteries are missing,
protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend
codes require the use of AC or AC/DC powered smoke alarms only. In existing construction, AC, AC/DC,
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.
and correctly installed. Units are easy to install, and do not require professional installation.
The following information applies to all four types of buildings listed below:
level of the home, in every bedroom or sleeping area, and in every bedroom hallway.
Smoke alarms may not detect fire on another floor or area of the home.
this smoke alarm may be used to provide additional protection in these facilities.
Smoke alarms cannot detect fires if the smoke does not reach them.
than stand-alone units since all units alarm when one detects smoke.
specific units in new construction or in different areas of the home.
if electricity fails. Units must be installed by a qualified electrician.
electricity fails. Units must be installed by a qualified electrician.
requirements in buildings not defined as “households.”
Multi-Family or Mixed Occupant Residence:
Smoke alarms cannot work without power.
Smoke alarms for the hearing impaired:
at night—and in the hallway between them.
Battery (DC) operated smoke alarms:
AC power, install both types of units.
installed by a qualified electrician.
AC powered smoke alarms:
Single-Family Residence:
Hotels and Motels:
They are not foolproof.
Institutions:
impaired.
alarm.
SA150B
Other Features Of Smoke Alarms 1
Special Compliance Considerations 1
Limitations Of Smoke Alarms 1
Where To Install Smoke Alarms 2
Where Not To Install Smoke Alarms 2
Protecting Your Family From Fire 2/3
What To Do In Case Of Fire 3
How To Install This Smoke Alarm 3
Weekly Testing 3/4
Regular Maintenance 4
If This Smoke Alarm Goes Into Alarm 4/5
If This Smoke Alarm Is Not Working Properly 4/5
10-Year Limited Warranty 4/5
This user’s manual contains important information about your smoke alarm’s operation. If you are installing
THIS USER’S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11” PAGES.
this smoke alarm for use by others, you must leave this manual—or a copy of it—with the end user.
consume combustible materials rapidly and spread quickly. Sources of these fires may
which smolder for hours before bursting into flame. Sources of these fires may include
For maximum protection, use both types of smoke alarms on each level of your home.
BLACK page numbers reference the original printed document.
Photoelectric smoke alarms are generally more effective at detecting smoldering fires
Ionization smoke alarms are generally more effective at detecting flaming fires which
RED page numbers reference this web version.
Cat. SA150B, SA150C
include paper burning in a wastebasket, or a grease fire in the kitchen.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
cigarettes burning in couches or bedding.
All Rights Reserved. ©1999 BRK Brands, Inc.
® · First Alert · Model

Additional local building and
unfinished attics. In new construction a smoke alarm shall also be installed in each sleeping room. Chapter 2 also reads
provide reliable early warning protection for those areas separated by a door from the areas protected by the required
2-2.1.1.1 Smoke alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and excluding crawl spaces and
as follows: 2-2.2.1: In new construction, where more than one smoke alarm is required by 2-2.1, alarms shall be so
install smoke alarms as close to the center of the ceiling as possible. If this is not possible, install the
ceiling, measured horizontally. Additional smoke alarms may be required depending on the length, angle, etc. of the
This equipment should be installed in accordance with the National Fire Protection Association’s Standard 72.
regulatory codes may apply in your area. Always check compliance requirements before beginning any
A-2.5.2.1 Smoke Detection-Are More Smoke Alarms Desirable? The required number of smoke alarms might not

install the first smoke alarm within 3 feet (0.9 m) of the peak of the
“Dead air” spaces may prevent smoke from reaching the smoke alarm. To avoid dead air spaces,
(if allowed by building codes), the top edge of smoke alarms should be placed between
4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line, below typical “dead air” spaces.
arranged that operation of any one alarm shall cause the operation of all alarms within the dwelling.
ceiling's slope. Refer to NFPA 72 for details on requirements for sloped or peaked ceilings.
National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101.
smoke alarm at least 4 inches (102 mm) from the wall or corner.
follow the installation recommendations below.
On a peaked, gabled, or cathedral ceiling,
smoke alarm near the kitchen.
installation.
out or fail at any time. You must test the unit weekly to ensure your continued protection. Smoke alarms cannot prevent
The National Fire Protection Association (NFPA), recommends one smoke alarm on every floor, in every sleeping area,
For minimum security install one smoke alarm as close to each sleeping area as possible. For more security, put one
injury, or death, since smoke
from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing
Like any electronic device, smoke alarms are made of components that can wear
It is recommended you replace a smoke alarm after 10 years from date of manufacture. See back of smoke alarm for
smoke alarm in all rooms, halls, storage areas, finished attics, and basements, where temperatures normally remain
inside walls only. Smoke alarms should be installed where temperatures normally remain between 40˚F (4˚C) and 100˚F
it may not be heard if: 1) the unit is located outside a closed or partially closed door, 2) residents recently consumed
“Agency Placement Recommendations” for details. For additional coverage, it is recommended that you install a
between 40˚F (4˚C) and 100˚F (38˚C). Make sure no door or other obstruction could keep smoke from reaching the
unit in each room. Many older mobile homes (especially those built before 1978) have little or no insulation. If your
mobile home is not well insulated, or if you are unsure of the amount of insulation, it is important to install units on
alcohol or drugs, 3) the alarm is drowned out by noise from stereo, TV, traffic, air conditioner or other appliances,
and in every bedroom. In new construction, the smoke alarms must be AC powered and interconnected. See
Check with your local Fire Department for current requirements in your area. If you install AC or AC/DC units,
Though the alarm horn in this unit meets or exceeds current standards,
The unit should be replaced immediately if it is not operating properly.
Test units used in RVs after the vehicle has been in storage, before every trip, and once a week
Specific requirements for smoke alarm installation vary from state to state and from region to region.
FEATURES RECOMMENDED FOR
SMOKE ALARMS WITH SILENCE
while in use. Failure to test units used in RVs as described may remove your protection.
NFPA RECOMMENDATIONS
ADDITIONAL PROTECTION
ADDITIONAL PROTECTION
ADDITIONAL PROTECTION
ADDITIONAL PROTECTION
INTERCONNECTED AC OR
RECOMMENDED FOR
AC/DC SMOKE ALARMS
INSTALLING SMOKE ALARMS IN MOBILE HOMES AND RVS
REQUIRED TO MEET
RECOMMENDED FOR
REQUIRED TO MEET
Smoke alarms may not have time to alarm before the fire itself causes damage,
If a hall is more than 40 feet (12 meters) long, install a unit at each end.
with matches, or fires caused by violent explosions resulting from escaping gas.
KEY:
or extinguish fires. They are not a substitute for property or life insurance.
LIVING ROOM
SINGLE-STORY RESIDENCE, APARTMENT,
DINING ROOM
BEDROOM LIVING ROOM
SINGLE-STORY RESIDENCE, APARTMENT,
it is recommended they be interconnected for added protection.
KITCHEN
MOBILE HOME
MOBILE HOME
BEDROOM
BEDROOM
BEDROOM
More specifically, install smoke alarms:
Smoke alarms may not be heard.
Smoke alarms are not foolproof.
Smoke alarms have a limited life.
FINISHED BASEMENT
BEDROOM BEDROOM HALL
LIVING ROOM KITCHEN
BEDROOM BEDROOM HALL
LIVING ROOM KITCHEN
MULTI-STORY RESIDENCE
MULTI-STORY RESIDENCE
IMPORTANT!
manufacture date.
smoke alarms.
(38˚C).
NEW CONSTRUCTION
For wall mounting · On ceilings,


not work until you remove the battery and reinstall it in the correct position (Follow polarity mark-
This warns you the unit will not operate without a battery.
Putting up smoke alarms is one step in protecting your family from fires. You must also reduce the chance a fire will start
Develop a family escape plan and practice it with everyone in your family, including small children. 1) Draw a floor plan of
your home and identify at least two exits from each room and one way to get out of each bedroom without opening the
what the alarm signal means and how to react to it. Teach them they must be prepared to leave the home by themselves
if needed; 5) Hold fire drills every 6 months and practice how to escape safely. Show children how to check if doors are
hot before opening them. Show them how to use an alternate exit if a door is hot and shouldn’t be opened. Teach them
Keep at least one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders
chimneys grease- and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable heaters and
the air, and when smoke reaches its sensing chamber, it alarms. It can give you more time to escape before fire spreads.
door; 2) Decide on a meeting place a safe distance from home, and make sure everyone knows to wait there; 3) Know
where to go to call the Fire Department from outside the home; 4) Make sure everyone—including all children—know
Keep alarms clean, and test them weekly. Replace smoke alarms immediately if they are not working properly. Smoke
Read “Where To Install Smoke Alarms” and “Where Not To Install Smoke Alarms” before beginning. This unit monitors
This unit can ONLY give an early warning of developing fires if it is installed, maintained and located where smoke can
reach it, and where all residents can hear it, as described in this manual. This unit will not sense gas, heat, or flame. It
Contact your Fire Department for ideas on making your home safer and on creating your own family escape plan.
cannot be linked to other devices. Connecting anything else to this unit may prevent it from
can prevent smoke from reaching the sensing chamber and prevent the unit from alarming.
Follow safety rules, and prevent hazardous situations: 1) Use smoking materials properly. Never smoke in bed.
emergency. Exposure to the horn at close range may harm your hearing. When testing the
in your home, and have a plan for escaping safely if one does. To have a good fire safety program, you must:
Install at least one smoke alarm on every level of your home, in every bedroom, and in every sleeping area.
units which use devices like flashing strobe lights to alert hearing impaired residents.
open flames, like candles, away from flammable materials; 8) Don’t let rubbish accumulate.
Only AC powered units are intended for installation over junction boxes.
or other reliable means of escape from an upper floor in case stairs are blocked.
slowly. Don’t open a hot door—use an alternate escape route.
unit, step back when the horn starts sounding.
and remembering what you have practiced.
alarms that do not work cannot alert you to a fire.
to stay close to the floor and crawl if necessary.
the unit from operating properly.
cannot prevent or extinguish fires.
working properly.
out safely.

alkaline battery in the “Alkaline Only” battery slot, make sure the bulb is not burned out, and re-test. If the light still does
The low battery warning “chirp” only identifies that the battery powering the
ing). This low battery warning should last for 30 days, but you should replace the battery immediately to con-
. The following batteries are acceptable as replacements to power the alarm:
Eveready Energizer #522, #1222; Duracell #MN1604; Rayovac 1604, D1604. The following batteries are acceptable as
You may also use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes.
Most carbon zinc batteries have an average service life of 1 year; most alkaline batteries have an average service life
should always shine during testing. If the horn sounds, but the light does not shine, install a fresh
inside of the cover and the sensor chamber. 3. Reconnect the battery. 4. Close the smoke alarm, and vac-
Never use water, cleaners or solvents since they
Your smoke alarm requires two 9V batteries—one to power the alarm, and an
replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, you MUST replace the
vacuum’s soft brush attachment. 1. Open the cover and disconnect the battery. 2. GENTLY vacuum the
Your smoke alarm requires one standard 9V battery. The following batteries are
of 1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the
smoke alarm and the environment in which it is installed. All the batteries specified above are acceptable
Use only the replacement batteries listed below. The unit may not operate properly with other
This method works best on flat ceilings. You may need
The Remote Flashlight Test method works best on ceilings up to 15 feet high. Wave a flashlight with a
direction—until the alarm sounds. If this method does not work, use the test button to make sure the
This unit has been designed to be as maintenance free as possible, but there are a few simple things
batteries. Never use rechargeable batteries since they may not provide a constant charge.
alarm is working. If it alarms, try the Remote Flashlight Test method again, making sure to wave the
alarm is getting weak. Testing the smoke alarm is the only way to make sure the Escape Light
strong beam rapidly back and forth in a straight line across the test button—at least 3 feet in each
: Eveready Energizer #522; Duracell #MN1604.
Failure to test units used in RVs as described may remove your protection.
to test wall-mounted units, or units on peaked or gabled ceilings manually.
battery immediately once the unit starts “chirping” (the “low battery warning”).
uum the outside of the cover. 5. Test the smoke alarm.
All batteries listed here are available at many local retail stores.
Choosing a replacement battery:
flashlight very rapidly across the test button.
alkaline battery to power the Escape Light
replacements to power the Escape Light
you must do to keep it working properly.
Models SA150B and SA150C Only:
not shine, the unit should be replaced.
Models SA90B and SA90C Only:
may damage the unit.
tinue your protection.
Rayovac 1604, D1604.
All Models:
properly.

Press and hold the test button on the cover of the unit for 5-20 seconds, or until the alarm sounds (the unit may continue
If it does not alarm
during testing, make sure the unit is receiving power. Make sure the battery is fresh, and installed correctly, then test it
NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to
your home. The built-in test switch accurately tests the unit’s operation as required by Underwriters Laboratories,
been Listed to Underwriters Laboratories, Inc. Safety Standards, and use it only as directed. Use of non-UL Listed
Inc. (UL). If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has
It is important to test this unit every week to make sure it is working properly. Using the test button or
During testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.
remote flashlight test feature are the only recommended ways to test this smoke alarm.
products or improper use of UL Listed products may affect the smoke alarm’s sensitivity.
This unit is designed to be mounted on the ceiling, or on the wall if necessary.
may unsnap from the base if it's opened too far. This will not
terminals on the smoke alarm. Match “+” to “+” and “-” to “-.”
shaken loose. If the battery is not snapped in completely, the
hammer, if necessary, until they are flush with the ceiling or
Push the battery in until it snaps in securely and cannot be
Models SA150B/C have two batteries—one powers the
You must reposition BOTH batteries. The Escape Light®
damage the unit—the cover hinge snaps back into place
unit cannot receive battery power. The smoke alarm may
beep briefly when you install the battery—this is normal.
to alarm for a few seconds after you release the button).
alarm, the other powers the Escape Light®.
you will hear a loud, repeating horn pattern:
again. If it still does not alarm, replace it immediately.
10.Close the cover all the way. 11.Test the smoke alarm. See “Weekly Testing.”
3 beeps, pause, 3 beeps, pause
requires an alkaline battery.
WEEKLY TESTING
Tools you will need:
a pencil.
easily.
wall.

normal use for a period of ten years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc. will
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the
product, use on improper voltage, current or battery, use contrary to the operating instructions, disassembly, repair or alteration
BRK Brands, Inc. shall not be liable for any incidental or consequential damages caused by the breach of any express or implied
incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions
Units under warranty and in need of repair should be returned, shipping prepaid, to BRK Brands, Inc., Attn.: Consumer
BRK Brands, Inc. makes no warranty, express or implied, written or oral, including that of merchantability or fitness
replace any defective smoke alarm without charge. During the next nine years, BRK Brands, Inc. will replace any defective smoke
selling this product do not have the right to alter, modify or any way change the terms and conditions of this warranty. In new
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to
BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship under
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the
original sales receipt. Proof of purchase is required to obtain warranty performance. Dealers, service centers, or retail stores
by anyone other than BRK Brands, Inc. Further, the warranty does not cover acts of God, such as fire, flood, hurricanes and
warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular
purpose is limited in duration for 10 years. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of
construction, if your smoke alarms were installed by a contractor, this warranty is valid for the homeowner at the time of
alarm at a charge to you not to exceed BRK Brands, Inc.’s cost. This is your exclusive warranty.
installation from the date of original installation and is not transferable.
Affairs, 3920 Enterprise Court, Aurora, IL 60504-8132.
for any particular purpose, with respect to the battery.
state, or province to province.
Coverage:
tornadoes.
Warranty:
Service:
mouth with a damp cloth. Never open a door before testing to see if it is hot. Call the Fire Department from outside, and
furnace, for example—open a nearby window or door and fan the smoke away from the unit. This will silence the alarm,
“Regular Maintenance,” and install a fresh battery, then test the smoke alarm again. If it fails to test properly when you
original purchase receipt (or write down date purchased) to: BRK Brands, Inc., Attn.: Consumer Affairs, 3920 Enterprise
uation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may
result in injury or death. If the unit alarms and you are not absolutely certain of the source of the
peaked or gabled ceiling, you may have to use the test
marked “Alkaline Only”). Make sure the bulb is working
(caused by cooking smoke, etc.). Removing the batteries disables the alarm so it cannot sense
smoke, and removes your protection. Instead open a window or fan the smoke away from the
immediately. Stay calm and follow your family escape plan. Stay as low to the ground as possible, and cover your
If the unit alarms and you are certain that the source of smoke is not a fire—cooking smoke or an extremely dusty
Smoke alarms may not operate properly because of dead, missing or weak batteries, a build-up of dirt, dust or
grease on the smoke alarm cover, or installation in an improper location. Clean the smoke alarm as described in
when no smoke is visible. • Clean the smoke alarm. (See “Regular Maintenance.”)
Remote Flashlight Test Feature • Make sure your flashlight has a strong enough beam.
rectly (the alkaline battery must be installed in the slot
Consumer Affairs to purchase a new one (if the bulb is
still under warranty, it will be replaced free of charge).
If the smoke alarm is still not operating properly, and it is still under warranty, send it, shipping prepaid to along with
This feature works best on flat ceilings. If you have a
does not light during testing. • Make sure both batteries are fresh and installed cor-
properly. If you suspect the bulb is burned out, call
If the unit alarms and you are not absolutely certain of the source of the smoke, get everyone out of the house
Smoke alarm “chirps” intermittently. • Check that the battery is installed correctly and is
working properly. (See “How to Install This Smoke
Smoke alarm “chirps” about once a minute. • Replace the battery. (See “Regular Maintenance.”)
Alarm horn doesn’t sound during testing. • Check that the battery is installed correctly and is
working properly. (See “How to Install This Smoke
During an alarm, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.
button manually. (See “Weekly Testing.”)
(See “Where To Install Smoke Alarms.”)
(like in response to cooking smoke). • Check the location of the smoke alarm.
(See “Where To Install Smoke Alarms.”)
(See “Where To Install Smoke Alarms.”)
Court, Aurora, IL 60504-8132. Enclose a note in the package describing what is wrong with the unit.
give them your address, then name. Read “What To Do In Case Of Fire” for more information.
Alarm” and “Weekly Testing.”)
Alarm” and “Weekly Testing.”)
use the test button, or if the problem persists, replace the smoke alarm immediately.
Do not try to fix the unit yourself—this will void your warranty!
smoke, get everyone out of the house immediately.
Problem... You should...
and once the smoke clears the unit will reset automatically.
unit. The alarm will reset automatically.
You experience frequent unwanted alarms
Alarm doesn’t sound when trying the
Models SA150B/SA150C Only:
Smoke alarm goes into alarm
Escape Light · ®
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.