738A ADEMCO™ INTERFACE MODULE Installation Guide

MODEL 738A

MOUNT THE MODULE

The 738A comes in a high‑impact plastic housing that you can mount directly to a wall, backboard, or other flat surface. For easy installation, the back of the housing contains multiple holes that allow you to mount the module on a single‑gang switch box or ring. The module can also be mounted in a DMP enclosure using the standard 3‑hole mounting pattern. Refer to Figure 2 and Figure 3 as needed during installation.

Figure 1738A Interface Module
1. Hold the plastic standoffs against the inside of the enclosure side wall.
DMP ADEMCO Interface Module (738A) — MODEL 738A diagram (page 1)
Fig. 1
2. Insert the included Phillips head screws from the outside of the enclosure into the standoffs. Tighten the screws.

The 738A Ademco Interface Module allows you to interface Ademco 5881 wireless receivers

3. Carefully snap the module onto the standoffs.

with the XR150/XR550 Series and XT30/XT50 Series panels. See “Compatibility” for specific

DMP ADEMCO Interface Module (738A) — MODEL 738A diagram (page 1)
Fig. 2

firmware levels. The module provides up to 32 supervised, programmable zones of Ademco

Alarm, and Ready to Arm status LEDs on an Ademco 5804BD. This

requires connecting an Ademco 5800TM to an XT30/XT50 panel.

Figure 2Mounting Hole Locations Figure 3: Standoff Installation
  • XT30/XT50 Series panels with firmware Version 101 or higher

WIRE THE MODULE 2

  • For a list of compatible Ademco devices, refer to “Ademco Compatibility”.

After properly mounting the module, follow the instructions to wire the module to the panel. Refer to Figure 4 for wiring details.

1. For Keypad Bus operation, connect a Model 300 4‑wire harness from the DMP BUS header to the Keypad Bus. For LX‑Bus operation, connect a Model 300 4‑wire harness from the DMP BUS header to the LX‑Bus.
2. Connect the provided Model 300 4‑wire harness from the RECEIVER header to the Ademco wireless receiver and 5800TM transmitter harness. The maximum distance between the Ademco wireless receiver and module is 3 feet.
3. When programming, connect a Model 330 dual‑ended programming cable from the PROG header to any DMP keypad.
4. Place the provided jumper across the PROGRAM header to enter the 738A programming mode. When you’re done programming, remove the jumper from the PROGRAM header and place it on one pin for future use.

Mounting · holes

Page 2 of the DMP ADEMCO Interface Module (738A) user manual — ZONE NO: ZONE NUMBER
Page 2 · click to enlarge
Page 2
DMP ADEMCO Interface Module (738A) — 3 Programming Options diagram (page 2)
Fig. 3 · 3 Programming Options
DMP Model 300 Wire ColorAdemco Harness Wire Color RedRed YellowYellow GreenGreen BlackBlack N/ABlue
Figure 4738A Wiring

3 Programming Options

PROGRAM THE MODULE

Use this section for reference when programming the module.

INIT ALL? NO YES INITIALIZATION

Select YES to reset all programming options to the factory default. Select NO to maintain all programming options at their current settings.

BUS: *KYPD LX PANEL BUS TYPE

Select the type of connection from the panel to the module. Choose either Keypad Bus or LX‑Bus connection. Press the CMD key to accept the selection. An asterisk displays to the left of the bus type selected.

HOUSE ID: 01 HOUSE ID

Select a number from 01 to 31 for the House ID. Enter a leading zero for numbers less than ten. The factory default is 01. The same House ID number must be programmed into any 5804BD Wireless Key transmitters to receive Armed, Alarm, and Ready to Arm status. Refer to the Ademco 5804BD Installation Instructions to enter the House ID.

ZONE? TEST ADD ZONE TEST OR ADD

Select ADD to program new zones into the system or select TEST to perform a zone test on existing zones. When performing a Zone Test, the 5881 receiver signal gain is reduced by 50%. When adding new zones to the system, select TEST to perform the Zone Test.

TRIPS END ZONE TEST TRIPS COUNTER

When TEST is selected, the Zone Test Trips Counter displays the number of times any programmed zone trips (alarm/short) during the Zone Test. The keypad buzzer sounds for 1 second each time a programmed zone trips. Select END to stop the zone test and display any failed zones.

ZONE: XX ‑FAIL ZONE TEST FAIL

The zone number of any zone that failed to trip at least once during the test displays for four seconds and the buzzer sounds for one second. The next failed zone displays. Press CMD to advance to the next failed zone.

ZONE NO: ZONE NUMBER

After selecting ADD, enter a wireless transmitter zone number to be programmed into the module at the Zone Number option. This zone number must correspond to a zone number programmed into the panel. Press CMD to accept the zone number.

When the module is connected to the Keypad Bus and any wireless input zones for a particular address are programmed (Ex: 11‑14 = Addr 1), the module responds to polls for this address. Other devices, such as keypads, cannot use this address. For more information about addressing the module, refer to Table 1 and Table 2.

Ademco Reciever

Page 3 of the DMP ADEMCO Interface Module (738A) user manual — Exit Programming
Page 3 · click to enlarge
Page 3
PANEL ADDRESSZONE NUMBERS XT30/XT50 SERIESXR150/XR550 SERIES 111 to 1411 to 14 221 to 2421 to 24 331 to 3431 to 34 441 to 4441 to 44 551 to 5451 to 54 661 to 6461 to 64 771 to 7471 to 74 881 to 8481 to 84
DMP ADEMCO Interface Module (738A) — *UN RF UR BR TRANSMITTER TYPE diagram (page 3)
Fig. 4
738A ADDRESSXR150/XR550 SERIES LX‑BUS PANEL ZONE RANGE LX‑BUS 1LX‑BUS 2LX‑BUS 3LX‑BUS 4LX‑BUS 5 1501601701801901 2502602702802902 3503603703803903 .................. 16516616716816916 17517617717817917 18518618718818918 .................. 32532632732832932
DMP ADEMCO Interface Module (738A) — *UN RF UR BR TRANSMITTER TYPE diagram (page 3)
Fig. 5
Table 1Keypad Bus Addresses
Table 2LX‑Bus Addresses

*UN RF UR BR TRANSMITTER TYPE

Enter a transmitter type by pressing the select key that corresponds to the type of transmitter used. An asterisk appears to the left of the transmitter type chosen. Default is UN. Press the CMD key to accept the selection. Refer to the installation instructions provided with the Ademco transmitter for additional information.

UN = Unused Zone UR = Unsupervised Transmitter

RF = Supervised Transmitter BR = Button Transmitter

When a transmitter reed switch, contact, or button is in a faulted condition, the corresponding panel zone is SHORTED. When the transmitter tamper is in a faulted condition, the corresponding panel zone is OPEN.

LEARN ID? NO YES TRANSMITTER IDENTIFICATION NUMBER

TRANSMIT NOW Select YES to enter Learn ID programming. The keypad displays TRANSMIT NOW. For the module to learn the transmitter identification number, the transmitter input (reed switch or contact) must be activated (tripped) and restored. The first activation beeps the program keypad once. Within four to eight seconds after the first activation the transmitter input must be tripped and restored a second time. The keypad beeps twice. The keypad displays the “learned” transmitter identification number (ID). To accept this number, press the CMD key.

ID: Select NO to manually enter the transmitter identification number. At ID: , enter the seven‑digit transmitter number printed under the bar code on the label attached to your Ademco transmitter. Press CMD to accept the number.

INPUT NO: _ TRANSMITTER INPUT NUMBER

Enter a number (1 to 4) to identify the transmitter input zone. When the transmitter ID is “learned,” the keypad displays the zone input number. Refer to the Ademco transmitter installation instructions for zone input information. Default is 1. Press the CMD key to accept the number. The display returns to ZONE NO for programming the next transmitter.

ALREADY ZONE: XX TRANSMITTER ALREADY LEARNED

This display indicates the transmitter has previously been learned as a zone and continuously displays until the Back Arrow or CMD key is pressed. Pressing the Back Arrow key returns programming to TRANSMIT NOW to allow a different transmitter to be learned. Pressing the CMD key returns programming to ZONE NO.

Exit Programming

Remove the jumper from the PROGRAM header to exit 738A programming mode. Place the jumper over one pin for future use. Remove the Model 330 cable and the DMP keypad from the PROG header. After exiting the programming mode, all zone states report to the panel as normal. Always test and verify all zones for proper communication.

Page 4 of the DMP ADEMCO Interface Module (738A) user manual — 738A LED Operation
Page 4 · click to enlarge
Page 4

ADDITIONAL INFORMATION

Wiring Specifications

The maximum wire distance between the Ademco™ wireless receiver and the module is 3 feet. Refer to the following LX‑Bus and Keypad bus wiring specifications.

DMP recommends using 18 or 22 AWG for all LX‑Bus and Keypad Bus connections. The maximum wire distance between any module and the DMP Keypad Bus or LX‑Bus circuit is 1,000 feet. To increase the wiring distance, install an auxiliary power supply, such as a DMP Model 505‑12. Maximum voltage drop between a panel or auxiliary power supply and any device is 2.0 VDC. If the voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit.

To maintain auxiliary power integrity when using 22‑gauge wire on Keypad Bus circuits, do not exceed 500 feet. When using 18‑gauge wire, do not exceed 1,000 feet. Maximum distance for any bus circuit is 2,500 feet regardless of wire gauge. Each 2,500 foot bus circuit supports a maximum of 40 LX‑Bus devices.

For additional information refer to the LX‑Bus/Keypad Bus Wiring Application Note (LT‑2031) and the 710 Bus Splitter/ Repeater Module Installation Guide (LT‑0310).

Keypad and LX‑Bus Connection

For simple installation, the module connects to the panel 4‑wire keypad data bus. The module can also connect to the on‑board LX‑Bus of an XR150/XR550 Series panel.

XR150/XR550 Series Connect the module directly to the Keypad Bus or the LX‑Bus (LX500‑LX900) connectors on the panel.

738A LED Operation

The green LED on the module indicates data transmission to the panel.

  • On —There are no transmitters programmed
  • Off —The module is not being programmed or it is not responding to the panel
  • Flashing —The module is transmitting data to the panel or it is being programmed
LEDLED CONDITIONSOUNDERSYSTEM STATUS RedON Steady2 BeepsArmed Away 3 BeepsArmed Stay or Instant FlashingPulsingFire Alarm SteadyArmed, Burglary Alarm GreenON Steady1 BeepDisarmed, Ready to Arm FlashingSilentDisarmed, Not Ready to Arm
Table 3LED and Sounder Operation
Page 5 of the DMP ADEMCO Interface Module (738A) user manual — Ademco 5804BD Panic Buttons
Page 5 · click to enlarge
Page 5

ADEMCO COMPATIBILITY

Compatible Ademco Wireless Transmitters and Receivers

Table 4 and Table 5 list current Ademco transmitters and receivers that have been tested by DMP and are compatible with the module. Other Ademco products have not been evaluated by DMP. The 738A module has not been tested by UL.

The module supports up to 32 wireless zones. The module can deliver all 32 zones to a DMP panel regardless of the number of zones assigned by the Ademco wireless receiver model number. For example, a Model 5881ENL 8‑Zone Receiver delivers 32 wireless zones to the module.

RECEIVER MODEL NUMBERXT30/XT50 SERIES AND XR150/XR550 SERIES 5881ENL 8‑Zone Receiver32 Zones 5881ENM 16 Zone Receiver32 Zones 5881ENH 64‑Zone Receiver32 Zones Note: Dip switches on the 5881 series receiver must be set to zero.
Table 4Ademco Receivers
SUPERVISEDADEMCO TYPEUNSUPERVISEDADEMCO TYPE 5802MN Miniature Panic ButtonBR or UR5802 Panic ButtonBR 5816 Window/DoorRF5803 3‑ButtonBR 5817 3‑ZoneRF5804 4‑ButtonBR 5890 Motion DetectorRF5804BD 4‑Button *BR * Note: For use with XT30/XT50 Series panels.* Note: For use with XT30/XT50 Series panels.
Table 5Ademco Transmitters

Ademco 5800TM Transmitter Module

The 738A supports the Armed, Alarm, and Ready to Arm status LEDs on an Ademco 5804BD. This requires connecting an Ademco 5800TM to an XT30/XT50 panel. When a 5800TM is connected as shown in Figure 4. the panel Armed, Alarm, and Ready to Arm status displays on the Ademco 5804BD Wireless Key LED and sounder. Table 3 describes the LED and sounder operation. Refer to the Ademco 5804BD Installation Instructions for proper button operation.

Ademco 5804BD Panic Buttons

Use 5804BD buttons A and C to send a panic signal to the DMP panel. Press the A and C buttons at the same time for two seconds to send a Zone 19 Panic signal to the central station receiver. The zone name information sent to the receiver contains the first address number that the module is answering.

Page 6 of the DMP ADEMCO Interface Module (738A) user manual — ADEMCO COMPATIBILITY
Page 6 · click to enlarge
Page 6

FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation.

The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter.

Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help.
738A ADEMCO MODEL 738A INTERFACE MODULE Specifications Primary Power 12 VDC Current Draw 75 mA Dimensions 5.50” W x 3.00” H x 0.75” D 13.97 cm W x 7.62 cm x H x 1.91 cm DCompatibility XR150/XR550 Series panels XT30/XT50 Series panels with firmware Version 101 or higher Certifications FCC Part 15 Accessories Model 300 4‑Wire Harness Designed, engineered, and manufactured in Springfield, MO using U.S. and global components. LT‑0377 20271I N T R U S I O N • F I R E • A C C E S S • N E T W O R K S 2500 North Partnership Boulevard Springfield, Missouri 65803‑8877 800.641.4282 | DMP.com

Ask about the DMP ADEMCO Interface Module (738A)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the DMP ADEMCO Interface Module (738A)

Be the first to ask — other owners or our team will answer.

Original document

DMP ADEMCO Interface Module (738A) manual PDF

6 pages·198 KB·Communications·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…