PROGRAM THE PANEL
The 1154 can be programmed with up to four zones. When programming the 1154 in the panel, refer to the panel programming guide as needed.

to four existing normally closed, hardwired zones (such as motion sensors, door & window contacts,
be connected to the existing panel’s 12 V auxillary power. Once connected, the 1154 Wireless Input Module converts up to four existing

hardwired zones into wireless zones. This allows the new DMP

The 1154 should be placed close to the existing non-DMP panel.

Mount the device on a flat surface such as a wall or single-gang box. When using the optional Model 376L plug-in power supply, mount the device near a wall outlet. See Figure 2 for an example of all mounting holes on the housing base. Use any combination.
Wire the zones and connect the receiver before installing the battery or connecting a power supply to the 1154. 1. Locate the existing Normally Closed contacts that you want to connect to the 1154. These contacts should be within 100 feet of the 1154. 2. Use 18 to 22 gauge wire to connect a zone device to terminals Z1+ and Z1-. 3. Repeat step 2 for the remaining zones as needed.
Use power from an existing panel to connect the 1154 to powered zones such as PIRs or glassbreak detectors. The existing panel must be connected to AC power. The powered zones must be connected to the existing panel or another power supply for power.


Use power from the optional Model 376L plug-in DC power supply to connect the 1154 to powered zones. The 1154 must be mounted near a wall outlet or other power source.
Power the 1154 and powered zones from the DMP Model 505-12 power supply or other external 12 VDC power supply with battery backup to remove the existing non-DMP panel from the setup. Use 18 to 22 gauge wire to connect the 1154.
1154 Input Power Terminal Block
Use a single CR123A 3 V battery to connect the 1154 to non-powered zones such as door or window contacts or battery-powered contacts. Observe polarity when installing the battery into the module.

FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This device complies with Industry Canada Licence-exempt RSS standards. Operation is subject to the following two conditions:
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand public.

XT30 panels with 1100D Series Wireless Receiver with Version
XT50 panels with integrated wireless receiver or 1100D Series
Life Expectancy 3 years Type 3 V Lithium CR123A
Dimensions 4.65” L x 3.10” W x 1.40” H 11.81 L x 7.87 W x 3.56 H cm
Designed, engineered, and manufactured in Springfield, MO using U.S. and global components.
Owners and our team usually reply within a day — and your question helps the next person too.