Controls the amount of input signal level neces- sary to turn the module’s signal output on and mute lower priority modules. Clockwise rotation increases the necessary input signal level required to produce audio output and mute lower priori- ty modules.
Controls the amount of time the signal output and priority muting of the module remains applied to the main unit’s buses after the input signal falls below the required minimum signal level (set by the threshold control).
IN IN
Sets the signal level threshold at which the mod- ule will begin to limit the level of its output signal. An LED to the left of the knob illuminates when the limiter is active. Clockwise rotation of the knob will allow more output before lim- iting, counterclockwise rotation will allow less. The limiter monitors the module’s output sig- nal, so increasing Gain will affect when limiting takes place.
Provides control over the level of input signal that can be applied to the internal signal buses of the main unit. Balances the input levels of various devices so that the main unit controls can be set to relatively uniform or optimum levels. 18-60 dB Gain range in MIC position, -2 to 40 dB in Line position.
The Treble control provides +/- 10 dB at 10 kHz. Clockwise rotation provides boost; coun- terclockwise rotation provides cut. Center position provides no effect.
The Bass control provides +/- 10 dB at 100 Hz. Clockwise rotation provides boost; counter- clockwise rotation provides cut. Center position provides no effect.
MIC/Line level input on screw terminal strip. Electronically balanced input.
Input level can be controlled by direct voltage input or by remote 10K-ohm pot.

GATING
1 2 3 4 HIGHEST LOWEST
Priority Level* This module can respond to 4 dif- ferent levels of priority. Priority 1 is the highest priority. It mutes modules with lower priorities and is never muted. Priority 2 can be muted by Priority 1 modules and can mute modules set for Priority Level 3 or 4. Priority 3 can be muted by either Priority 1 or 2 modules and can mute Priority 4 modules. Priority 4 modules are muted by all higher priority mod- ules. Remove all jumpers for “no mute” setting.
DISABLED
A BUS ASSIGNMENT
PRIORITIES
J13
B BOTH
J11
GATING ENABLE
J10
J12
J4
BUS ASSIGNMENT
PHANTOM PWR
LINE MIC
J2
MIC/LINE SWITCH
PHANTOM POWER
* The number of priority levels avail- able is determined by the equipment the modules are used in.
ON
OFF
MIC LEVEL INPUT
Gating Gating (turning off) of the modules output when insufficient audio is present at the input can be disabled. Detection of audio for the purpose of muting lower priority modules is always active regardless of this jumper setting.
Phantom Power 24V Phantom power can be supplied to condensor microphones when jumper is set to ON position. Leave OFF for dynamic mics.
Bus Assignment This module can be set to operate so that the mono signal can be sent to the main unit’s A bus, B bus, or both buses.
MIC/LINE Switch Sets input gain range for the intended input device. MIC gain range 18 – 60 dB, LINE gain range -2 – 40 dB.


Use this wiring when the source equipment supplies a balanced, 3-wire output signal.
Connect the shield wire of the source signal to the "G" terminal of the input. If the "+" signal lead of the source can be identified, connect it to the plus "+" terminal of the input. If the source lead polarity cannot be identified, connect either of the hot leads to the plus "+" terminal. Connect the remaining lead to the minus "-" terminal of the input.
When the source device provides only an unbalanced output (signal and ground), the input module should be wired with the "-" input shorted to ground (G). The unbalanced signal's shield wire is con- nected to the input module’s ground and the signal hot wire is connected to the "+" terminal. Since unbalanced connections do not provide the same amount of noise immunity that a balanced connection does, the connection distances should be made as short as possible.
MIC/LINE
IN
JUMPER WIRE
Balanced Connection · Unbalanced Connection


0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

These configurations use the included wall-mounted remote panel. Up to 2,000 feet of #24 wire can be run from the remote panel to the LMR1S.
Single Conductor Shieldes Remote Connections The maximum wire run length for this configuration is 200 feet. Use one-conductor shielded wire for this configuration.
LMR1S Remote Panel LMR1S Remote Panel
SHIELD
GND
JUMPER FROM CS+
TO WIPER TERMINAL
SHIELD
Two-Conductor Shielded Remote Connections This configuration is recommended when wire runs up to 2,000 feet are necessary. Use two- conductor shielded wire for this connection.
LMR1S Remote Panel LMR1S Remote Panel
GND
SHIELD
WIPER
SHIELD
SHIELD
cs+ · cs+ · cs+