SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS for the Basement Watchdog combination sump pump system. You will need to refer to it before attempting any installation or maintenance. ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property damage, serious injury, or death. It is important to read this manual, even if you did not install the Basement Watchdog combination sump pump, since this manual contains safety information regarding the use and maintenance of this product. DO NOT DISCARD THIS MANUAL.


CAUTION
ELECTRICAL PRECAUTIONS
To reduce the risk of hazards that can cause injury or property damage, observe the following precautions:
! WARNING
POSITIVE POST HAS LARGER DIAMETER
NEGATIVE POST HAS SMALLER DIAMETER
This installation must be in accordance with the National Electric Code and all applicable local codes and ordinances.
Risk of electrical shock and fire hazard. May result in death, serious injury, shock or burns. To help reduce these risks, observe the following precautions:
Explosive gases could cause serious injury or death. Cigarettes, flames or sparks could cause battery to explode in enclosed spaces. Charge in well-ventilated area. Always shield eyes and face from battery. Keep vent caps tight and level.

To help reduce these risks, observe the following precautions:
NEGATIVE
Glentronics, Inc. 645 Heathrow Drive, Lincolnshire, IL 60069
POST
! WARNING / POISON
Sulfuric acid can cause blindness or severe burns. Avoid contact with skin, eyes or clothing. In the event of accident, flush with water and call a physician immediately. KEEP OUT OF REACH OF CHILDREN.
Do not use system to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.


The Basement Watchdog combination sump pump system is designed to provide both primary and backup pumping capabilities. The primary pump will operate as long as it is receiving AC power. If the power is interrupted, or more water is coming into the sump than the AC pump can handle, the backup sump pump will begin pumping automatically. The backup system has unique monitoring features that diagnose a problem and sound an alarm. A light on the display panel of the control unit will indicate the cause of the alarm and the corrective action. The two systems have been preassembled for easy installation. The Basement Watchdog Sump Pump System includes:
Float Switch
Primary Pump
Backup
Float Switch
Pump
Primary Pump
A 1/3 HP primary pump with a caged dual
float switch, and a blue piggyback controller that plugs into the wall outlet A backup pump supported by a bracket A control unit for the backup pump with a
Pump Controller
Rubber Union
battery fluid sensor, a dual float switch, and battery cables A cable tie to attach the backup control unit
to the discharge pipe Two cable ties to secure the other wires to
the discharge pipe A battery cap with a hole to accommodate
the fluid sensor A battery charger A rubber union You will also need to supply: A Basement Watchdog Emergency Standby
Pump Controller
Fluid Sensor
Battery Cap
Battery, Basement Watchdog Big Standby Battery or Basement Watchdog Maintenance Free (AGM) Standby Battery. DO NOT use an automotive battery with this system Six quarts of 1.265 specific gravity battery
Cable Ties
For some installations you may also need additional items: 1-1/2” rigid PVC pipe A 1-1/2” PVC pipe connector or a 1-1/2” rubber union PVC pipe cleaner and cement

acid (if using a wet cell standby battery). Battery fluid is not needed if using the Basement Watchdog Maintenance Free (AGM) Standby Battery. A battery box

The internal construction of some wet cell batteries may not be compatible with this system. Glentronics can not guarantee the compatibility of other brands of batteries. The use of a Basement Watchdog battery is HIGHLY recommended.
Power supply requirements . . . 115 volts, 60 Hz AC pump pumping capacity. . . 3100 GPH @ 10’ DC pump pumping capacity. . . 1000 GPH @ 10’ Overall dimensions 10”W x 17-3/4” H Pump housings & strainers Non-corrosive

sump pit is not clean, remove as much of the debris as possible. You should place a pump stand or bricks on the floor of the sump pit to raise the pump above the debris. If you are replacing an old sump pump, unplug the pump from the outlet. 1. Remove the check valve or rubber union. If the existing system is installed without a check valve or rubber union, saw the pipe apart above the sump pit per #3 below. Discard the check valve. The Basement Watchdog system contains built-in check valves, so the old check valve will not be needed. 2. Remove the old pump from the pit, and unscrew the pipe and pipe adapter from the pump. 3. Measure the distance from the bottom of the sump pit (or from the top of the bricks in the sump pit) to the end of the discharge pipe. Subtract 18-3/4 inches (the height of the pump system + 1 inch). Cut a piece of 1-1/2” rigid PVC pipe to that length. 4. (a) Connect this piece to the discharge pipe by cementing the two pieces together with a 1-1/2” PVC pipe connector. (Follow the instructions on the PVC pipe cleaner and cement.) or, (b) connect the two pieces of pipe together with a rubber union. 5. Remove the assembled pump system from the shipping carton by lifting the strap at the bottom of the unit and supporting the top of the unit with your hand. Stand the unit on the ground near the sump pit. Visually inspect your pump. Products may be damaged during shipping. If the product has been damaged, contact your place of purchase or Glentronics before installation. 6. Slip the lifting strap off of the pump. 7. Remove the attached cords and controllers from the carton and place them next to the pump system. BE SURE THE CORDS AND CONTROLLERS DO NOT FALL INTO THE SUMP PIT DURING THE INSTALLATION. 8. Loosen the hose clamps on the enclosed rubber union, and slide the union up on the discharge pipe until it is even with the bottom of the pipe. 9. Lift the combination system by the handle on the primary pump and lower it into the sump pit. Make sure it is level. 10. Inspect the two float switches. They should both be vertical and positioned so that they move smoothly without hitting the pump or the wall of the sump pit. 11. Inspect all of the screws on the hose clamps

of the no hub couplings (primary and backup pumps). They should be tight. 12. Position the top of the pump system pipe so it is directly below the discharge pipe. Slide the rubber union down until half of the rubber union is covering the pump pipe, and the other half is covering the bottom of the discharge pipe. Tighten the hose clamp screws securely.
The Basement Watchdog combination system is compact and will fit in a sump pit as small as 10” wide and 14” high (the size of a 5 gallon bucket). It measures 173/4“ inches from the bottom of the pump to the top of the Y- connector where it will be attached to the discharge pipe. Use a pit that conforms to all local codes, and check the code to see if a gate valve or ball valve is required. The path of the vertical discharge pipe to an exterior wall should have the shortest path with the fewest turns. The more turns will reduce the pumping capacity.The discharge pipe must be positioned in a downward slope so any remaining water will drain away. Failure to do this will prevent water from exiting the pit and damage the pump if the line freezes. (see Diagram A) The system should be placed on a flat surface free from dirt and debris. If the bottom of the

173/4“




before you take them home. A battery is activated when the acid is added, and then it slowly begins to deteriorate as it ages. By adding the acid just before use, the battery will always be fresh. Use 1.265 specific gravity battery acid to fill the battery. It is available where you purchased the battery.


The Basement Watchdog Emergency Standby Battery has been designed to run this system for 50 hours, based on a 10% duty cycle. However, most of the time the pump will turn on and off, and the battery will run the pump intermittently for days. In addition, the unique materials in the battery enable it to last longer in standby service. To extend the run time of the pump, use the Basement Watchdog Big Standby Battery. It will run this pump for 100 hours, based on a 10% duty cycle. Why will it run longer? Because the Big battery is rated for other Basement Watchdog pumps that draw more power (amps). The emergency pump puts less drain on the battery, so the battery lasts longer. NOTE: The battery will not run the primary pump.
NOTE: Basement Watchdog batteries now come in two configurations. The tops of the batteries look different, and the directions for filling the batteries and connecting the fluid sensor will vary slightly. Instructions for both batteries follow. If the top of your battery looks like photo A, follow the instructions on this page. If the top of your battery looks like photo B on page 5, follow the instructions on page 5.
Contains sulfuric acid. Wear eye and clothing protection. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eyes, flush with water for 10 minutes and get medical attention. Review the safety instructions on page 1.
necessary. The battery acid may bubble at this time and give off a sulfur-like smell, but this is normal. After the battery has been filled, screw the caps on the top of the battery.
1. If you have not purchased a battery box, place a plastic garbage bag on the floor with some paper towels or newspaper on top of it while you are filling the battery. Place the dry (unfilled) battery on top of the paper. If you have purchased a battery box, place it directly on the floor and place the battery in it. 2. Remove the foil seal on the top of the battery. 3. (a) Carefully push in the perforated tab at the top of the acid pack. Lift up the large tab and pull out the dispensing hose. Hold the hose upright above the pack and squeeze the hose forcing all the acid back into the pack. (b) Position the acid pack and battery as shown at the right. Pinch the end of the hose together and cut off the tip. Insert the end of the hose into each cell. Control the flow by pinching the hose with thumb and forefinger. Fill each cell of the battery to a level just covering the battery plates, and then go back and top off each cell equally. It is important to have the cells filled equally or the battery will not operate properly. The acid should reach a level about 3/16” below the cap rings. (Diagram B) A newly filled battery will sometimes require additional acid after about ten minutes. Re- examine the fill level and add additional acid, if
Within 15-30 minutes of adding acid, the battery will be 70-80% charged. The system will then finish charging the battery. During this time, the alarm may sound. This is normal.
Remove the paper and plastic bag from beneath the battery. Roll it up with the plastic on the outside and place it in the trash.

DO NOT insert the fluid sensor into any battery except a Basement Watchdog battery. DO NOT use the enclosed battery cap on any battery except a Basement Watchdog battery. DO NOT drill a hole in the cap or the top of another brand of battery to accommodate the fluid sensor. Batteries emit explosive gases, which can cause serious injury or death. PREPARING THE BASEMENT WATCHDOG STANDBY BATTERY
Do not throw an old battery in the trash. Take it to a service station or recycling center.
The Basement Watchdog batteries are shipped dry (without acid) so they never lose power


shown below. Pinch the end of the hose together and cut off the tip. Insert the end of the hose into each cell. Control the flow by pinching the hose with thumb and forefinger. Fill each cell of the battery to a level just covering the battery plates, and then go back and top off each cell equally. It is important to have the cells filled equally or the battery will not operate properly. The acid should reach a level about 3/16” below the cap rings. (Diagram B)

Risk of electrical shock or battery explosion, which can cause serious injury or death. Unplug the main AC pump to avoid electrical shock. Wear eye protection. Work in a well- ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1.
If your battery looks like the battery above, follow these directions.
A newly filled battery will sometimes require additional acid after about ten minutes. Reexamine the fill level and add additional acid, if necessary. The battery acid may bubble at this time and give off a sulfur-like smell, but this is normal. After the battery has been filled, press the two caps on the top of the battery.
When you position the backup system control unit on the discharge pipe, be sure the charger cord will reach the AC power outlet and the pump cable and the float switch will reach the bottom of the sump. Position the unit in a well- ventilated area. Do not place anything on top of the battery. (Diagram C)
Within 15-30 minutes of adding acid, the battery will be 70-80% charged. The system will then finish charging the battery. During this time, the alarm may sound. This is normal.
Remove the paper and plastic bag from beneath the battery. Roll it up with the plastic on the outside and place it in the trash.
may have been emitted from the battery. (a) If you have battery A, replace the battery cap that is 2nd from the POSITIVE (+) post of the battery with the battery cap that is provided in the Basement Watchdog package. An arrow on the top of the battery marks this position. There are two holes in the battery cap. Insert the fluid sensor in the hole that is off-center on the top of the cap. Do not glue the sensor into the cap. (b) If you have battery B, a hole has been molded into the top of the battery to accept the fluid sensor rod. The sensor hole is marked by the label on top of the battery. Hold the sensor straight and press it firmly into the hole all the way up to the connector. Do not bend the sensor rod.
When you fill the battery for the FIRST time, it will be the ONLY time you add acid to the battery. In the future, when the fluid level is low, add distilled water to the cells. Never add more acid.




If you are not using the Basement Watchdog battery, you cannot use the battery fluid sensor. However, you must attach the sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously. The Basement Watchdog sump pump system will not warn you if the fluid level is low in this configuration. You will need to check your battery every couple of months to see if it needs water. If the battery dries out, the system will not work. If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE (+) post of the battery or the or the alarm will sound continuously.

4. Connecting the battery: Remove the wing nuts from the battery terminals. Remove the security tag from the battery cables. Attach the battery cables to the battery…the WHITE wire to the NEGATIVE (-) post, and then the BLACK wire to the POSITIVE (+) post. Replace the wing nuts and tighten. Note: Connecting the cables to the wrong posts will damage the controller. 5. Connecting the charger: Immediately plug the charger into the charger jack on the back of the control unit, then into an AC outlet on the wall. 6. If the pump alarm is sounding, press the RED button to silence the alarm. 7. Replace the battery box cover. 8. Connecting the primary pump: Plug the piggyback controller into a properly grounded 3-prong outlet. Then plug the primary pump into the receptacle on the controller. 9. For a neater installation, secure the cables from the controllers to the discharge pipe in a couple places with the additional cable ties. Make sure the wires are not touching each other or overlapping each other. 10. After the initial installation, be sure to check each pump for proper operation. To check the primary pump, fill the sump with water and observe the pump through several full cycles. The primary pump should run for 10 seconds after the lower float drops. To check the operation of the backup pump, manually raise the backup float and let it go. The




backup pump will run for approximately 25-30 seconds. After the backup pump has stopped, push the red button.
Batteries and sump pumps need maintenance. The control unit on the backup system monitors the battery and power conditions, and sounds an alarm when maintenance is required. Below is an explanation of the warnings and alarms.
Measuring the battery fluid level is one of the most important features of the system. It is important to check the battery fluid levels at least once every 4-6 months. Detailed instructions on adding distilled water to the battery can be found within the Understanding the Warnings & Alarms section of this manual (page 7, 2 Water). If you are not using a Basement Watchdog standby battery, you cannot use the battery fluid sensor. You will need to attach the fluid sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously. The system will NOT warn you if the fluid level is low in this configuration. You will need to check your battery every couple of months to see if it needs water. If the battery dries out, the system will not work. If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously.

The dual float switch on the primary pump contains two large floating rings enclosed within a protective cage. Water will lift the bottom float by 1/4”, which will activate the pump. If for any reason the lower float does not activate the pump, the water will rise to the second float, and it will activate the pump. As the pump evacuates the water from the pit, the floats will drop. The pump will run for an additional 10 seconds to extend the cycle after the lower float drops. The blue controller for the primary pump powers this switch.



During a power outage, or if more water is entering the sump than the primary pump can handle, the backup pump will automatically begin pumping. It also has a dual float switch, so if one float fails to activate the pump, the second float will activate the pump as soon as the water reaches that level. As the water recedes below the float switch, a timer in the control unit will run the pump an additional 25-30 seconds to evacuate the pit.


The Basement Watchdog backup control unit features a series of warning lights that pinpoint potential problems. In addition, an alarm sounds to alert you to the problem. In some cases the lights and alarm will go off automatically when the problem has been solved. In others, the RED button must be pushed to silence the alarm. Refer to the table on page 7 for a quick review of the features and their corresponding alarm status.
While the pumps are active, water will come out of the 1/8” hole that is located on the top of the main pump, and out of the 3/16” hole in the elbow of the backup pump. This is normal. The holes are needed to prevent an air lock within the system. DO NOT obstruct the holes or an air lock may prevent the system from activating.
NEGATIVE
POST
POST


The WATER and BATTERY alarms cannot be silenced. Both require immediate attention. 1 Power There are several causes for power failure. The most common is a power outage by your electric company. During this emergency, the Basement Watchdog system will automatically switch to battery power and protect your basement from flooding. You can silence the POWER alarm by sliding the audible alarm switch to OFF. The alarm will be silenced, but the light will stay on. The system will continue to operate while the power alarm is silenced. Be sure to slide the switch to the ON position when power is restored to resume full monitoring capability. 1. If the power is on in the rest of the house, check the outlet, the home circuit breaker or the fuse box for failure, and correct the problem.
which can cause serious injury or death. Wear eye protection. Work in a well- ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1. If this warning light and alarm are on, you need to add distilled water to the battery. (This alarm cannot be silenced. When the battery is refilled and the sensor is replaced, the alarm will go off automatically.) To refill the battery: 1. Unplug the charger and the blue AC pump controller from the wall outlet. 2. If you are using a battery box, remove the cover and fan the area around the top of the battery with a piece of cardboard (or another non-metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery. 3. Then unscrew the wing nuts and remove the battery cables and the fluid sensor from the battery. 4. Remove the battery caps. Add distilled water to each cell. If distilled water is not available, tap water with a low mineral content may be used. Well water is not recommended. NEVER ADD MORE ACID. Fill the battery to level 2 as shown in Diagram B on page 4. (The Basement Watchdog battery filler will automatically fill the level to the correct height. See enclosed order form.)

1 2 3 4 5


SILENCING THE ALARM DURING AN EMERGENCY The Basement Watchdog backup sump pump system is equipped with a switch that will silence the audible alarm during an extended emergency. The POWER and PUMP alarms can be silenced during a power outage or during heavy rains when the pump is activated repeatedly. To silence the POWER and PUMP alarms, slide the audible alarm switch to OFF. The POWER and/or the PUMP light will remain on, but the audible alarm will not sound. When the emergency has ended, slide the switch to the ON position to resume the full monitoring capability, or you will not be warned the next time an emergency occurs.


5. Using a paper towel, clean the underneath portion of the battery cap that contains the fluid sensor. Replace the battery caps and the fluid sensor. Be sure the fluid sensor is positioned in the 2nd cell from the positive post. Depending on which battery you own, the sensor will fit in the top of the battery cap or in the molded hole on the top of the battery. The location is marked with an arrow on the top of the battery. The warning light and alarm will turn off automatically when the battery is refilled and the sensor is replaced. 6. Replace the battery cables, the WHITE to the NEGATIVE (-) post, and the BLACK to the POSITIVE (+) post. Replace the wing nuts and tighten. 7. Replace the battery box cover. 8. Plug the charger and the blue AC controller back into the outlet. 3 Pump

2. Check the charger. Make sure it is securely plugged into the wall outlet. Make sure the power outlet is working. 3. Check the charger plug that fits into the rear panel of the control unit. Make sure it is securely plugged into the control unit. The control unit must receive 115 volts AC +/- 5% from the AC outlet. Any voltage lower than 110 volts will activate the POWER alarm. Lower voltages can be caused by utility brown outs or a heavy power draw from other appliances on the same circuit.

If all the connections are secure and the wall outlet is operating, but the POWER warning light is still on, replace the charger unit. Contact Glentronics, Inc. at 800-991-0466, option 3. 2 Water

When the water rises in the sump pit and lifts the float switch, the pump will begin pumping, and the PUMP light and alarm will turn on. The pump warning stays on to alert you to the fact that the standby system was used to empty the water from the sump. Try to determine what caused the system to activate. ! DANGER
Risk of electrical shock or battery explosion,




Risk of electrical shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a well- ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. Review the safety instructions on page 1.
YOU WILL BE DISCONNECTING ALL THE WIRES. BE SURE THEY DO NOT FALL INTO THE SUMP PIT. SEE DIAGRAM ON PAGE 12 FOR PARTS DESCRIPTION.



1. Unplug the primary pump from the blue controller. 2. Remove the charger plug from the back of the backup controller. 3. Unplug the backup pump from the back of the backup controller. 4. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. Fan the area around the top of the battery with a piece of cardboard (or another nonmetallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery. 5. Remove the sensor from the battery. 6. Remove the battery wires from the battery terminals. Be sure they do not touch each other while one is connected to the battery. 7. Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes. The water trapped in the pipe will pour out into the sump as the rubber union is loosened. 8. Separate the pump assembly from the rubber union and lift it out of the sump by the handle on the primary pump. 9. Turn the assembly up side down over the sump pit to allow the remaining water in the system to drain. 10. Loosen the screws on the no-hub connector on the elbow of the backup pump. 11. Unscrew the screw on the bottom of the pump bracket with a Phillips head screwdriver, and lift the pump off of the bracket. Then pull the pump down out of the no-hub connector. 12. Unscrew the check valve on the elbow of the backup pump. Now reverse the process.





13. Screw the check valve on to the new pump. (You can use the existing check valve, or preferably replace it with a new one.) 14. You must drill a 3/16” hole in the elbow of the new pump to prevent an air lock in the system. An air lock will prevent the pump from operating. Drill the hole on a downward slope below the check valve on the elbow. 15. Push the pump and check valve back up into the no-hub connector, and place the pump on the pump bracket. 16. Screw the pump onto the bracket. 17. Tighten the hose clamp on the no-hub connector. 18. Lower the pump system back into the sump pit. 19. Connect the top of the system to the rubber
union and tighten the hose clamp. 20. Connect the battery cables to the battery terminals, WHITE to the NEGATIVE (-) post, and BLACK to the POSITIVE (+) post. 21. Insert the fluid sensor into the top of the battery and replace the cover of the battery box. 22. Plug the backup pump into the back of the backup controller. 23. Plug the charger into the back of the backup controller. 24. Plug the primary pump into the blue controller.
REPLACING THE BACKUP PUMP Before you begin this process you will need a new backup pump. You may also want to change the check valves at this time. The backup pump uses a 1-1/4” check valve, the primary pump uses a 1-1/2” check valve. (See parts list on page 12.)

Before you begin this process you will need a new AC pump. You may also want to change the




emitted from the battery. 5. Remove the sensor from the battery. 6. Remove the battery wires from the battery terminals. Be sure they do not touch each other while one is connected to the battery. 7. Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes. The water trapped in the pipe will pour out into the sump as the rubber union is loosened. 8. Separate the pump assembly from the rubber union and lift it out of the sump by the handle on the primary pump.
24. Connect the top of the system to the rubber union and tighten the hose clamp. 25. Connect the battery cables to the battery terminals, WHITE to the NEGATIVE (-) post, and BLACK to the POSITIVE (+) post. 26. Insert the fluid sensor into the top of the battery and replace the cover of the battery box. 27. Plug the backup pump into the back of the backup controller. 28. Plug the charger into the back of the backup controller. 29. Plug the primary pump into the blue controller. 4 System
5,6





This green light should always be flashing. It indicates that the system is operating, and the battery is connected. If this light is off:



OUT
14. Remove the Y-connector. 15. Unscrew the primary pump check valve. 16. Carefully slide the backup pump and bracket out of the handle of the primary pump. Now reverse the process. 17. Carefully slide the backup pump and bracket into the handle of the new primary pump. 18. Screw in the check valve on the top of the primary pump. (You can use the existing check valve, or preferably replace it with a new one.) 19. Connect the Y-connector to the top of the check valve with the no-hub connector and tighten the hose clamp. 20. Connect the backup pump to the other side of the Y-connector with the other no-hub connector. 21. Replace the caged float switch by tightening it with its hose clamp. 22. Replace the backup pump float switch using 2 new cable ties. Make sure the float moves easily, and will not get hung up on the pump. 23. Lower the pump back into the pit by the handle of the primary pump.
check valves at this time. The backup pump uses a 1-1/4” check valve, the primary pump uses a 1-1/2” check valve. (See parts list on page 12.)
YOU WILL BE DISCONNECTING ALL THE WIRES. BE SURE THEY DO NOT FALL INTO THE SUMP PIT. SEE DIAGRAM ON PAGE 12 FOR PARTS DESCRIPTION.


1. Unplug the primary pump from the blue controller. 2. Remove the charger plug from the back of the backup controller. 3. Unplug the backup pump from the back of the backup controller. 4. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. Fan the area around the top of the battery with a piece of cardboard (or another nonmetallic material) to remove any hydrogen or oxygen gas that may have been
Risk of electrical shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a well- ventilated area. Do not smoke of allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. Review the safety instructions on page 1.
This light and alarm will go on when the control unit senses that the battery has approximately 1/2 hour of continuous pumping energy left. This alarm cannot be silenced. It indicates that your battery is discharged or defective and

immediate action needs to be taken to replace the battery or clean the terminals. This alarm will sound when:
If the battery is relatively new and the battery alarm is activated, before you replace the battery, call the Glentronics service department. The phone number is 800-991-0466, option 3.





Risk of electrical shock or battery explosion, which can cause serious injury of death. Wear eye protection. Work in a well-ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1. 1. Unplug the charger and blue AC controller from the wall outlet. 2. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. 3. Fan the area around the top of the battery with a piece of cardboard (or another non- metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery. 4. Remove the fluid sensor from the battery. Unscrew the wing nuts. Remove the battery cables. 5. Clean the battery posts with a battery terminal cleaner or a wire brush. 6. Clean any corrosion off of the ring connectors on the ends of the battery wires. Us a stiff brush or sandpaper. DO NOT apply corrosion resisting sprays or pads to the terminal rings or posts after you have cleaned them, since this could prevent the system from charging properly. 7. Replace the fluid sensor in the top of the battery. Then replace the battery cables, WHITE to the NEGATIVE (-) post and BLACK to the POSITIVE (+) post. Tighten the wing nuts and replace the cover of the battery box. 8. Plug the charger and the blue AC pump controller back into the wall outlet. 9. You may have to press the RED button to silence the PUMP alarm.
Check the battery cables and the battery terminals for corrosion. Clean and tighten them as needed. The procedure is described on the following page.
If the battery alarm goes on while the pump is running and the power is out, you will have a minimum of 1/2 hour of pumping time to replace the battery. (In most cases, the pump does not run continuously, and therefore, you actually have a longer time to replace it.) You will not be able to silence the alarm. Left unattended, the basement will flood. In a severe emergency, if a replacement battery is not available, you could temporarily use your car battery. Once the AC power is restored, the battery will recharge automatically, unless it is old or damaged. The alarm will go off when the AC power is restored and the pumping energy reaches 1/2 hour or more. In the event that your Basement Watchdog backup sump pump has pumped for an extended period of time, the battery may be very depleted. In this condition, when the AC power is returned to the unit, a battery alarm will continue to sound. The battery may need a longer period to recharge or require an automotive or marine battery charger. For a faster recharge, an automotive or marine battery charger can be used to recharge the battery. Follow the manufacturer’s instruction and safety information included with the charger. Make sure the backup control unit is disconnected from the battery.
Risk of electric shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a well- ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1.


REFER TO THE PHOTOS BELOW AND ON PAGE 11
Basement Watchdog batteries come in two configurations. (A) One has six battery caps that screw into the top of the battery, and the fluid sensor fits in the cap with the two holes. (B) The other battery has two large caps that each snap over 3 holes. The sensor hole in this battery is molded in the top of the battery.





another nonmetallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery. 3. Remove the fluid sensor from the top of the battery. If the sensor was in the cap of the battery, remove the battery cap and save it for use in a new battery. 4. Unscrew the wing nuts and remove the battery cables. 5. Remove the old battery. Fill the battery following the instructions on page 4. 6. Clean any corrosion off of the wire ring connectors on the end of the battery cables. Use a wire brush or sandpaper. DO NOT apply corrosion resisting sprays or pads to the

pump will run for an additional 10 seconds after the float returns to the original position. It will not damage the pump to run it for this short time if the sump pit is dry. However, DO NOT hold the float up for an extended time without water in the sump.
The TEST button may be used to check the backup pump and system. Push the TEST button. This will activate the pump for as long as you hold the button.

It is important to manually test the float switch periodically or after any maintenance.


Lift the float up and let go. This will activate the pump. The control unit will run the pump for approximately 25-30 seconds so it can empty all the water in the sump pit. If there is no water in the pit, the pump can run dry for this amount of time. The alarm will sound and the PUMP light will go on. After the pump has stopped, push the RED button to silence the alarm. If the RED button is pressed before the pump has stopped, the alarm will go off temporarily. Wait for the pump to stop pumping, and then push the RED button to completely silence the alarm.

Maintenance should be performed 1-2 times per year.



terminal rings or posts after you have cleaned them, since this could prevent the battery from charging properly. 7. Replace the battery cables, WHITE to the NEGATIVE (-) post and BLACK to the POSITIVE (+) post. 8. (a) If the new battery has six caps, rinse and dry the cap with the extra hole from the old battery to remove any residue. Replace the battery cap that is 2nd from the POSITIVE post with the cap from the old battery. Insert the fluid sensor in the cap and put the cap you removed from the new battery on the old battery. (b) If the new battery has the sensor hole molded in the top you will not need to save the cap from the old battery, press the sensor firmly into the hole. Do not bend the sensor rod. 9. Plug the charger and the blue AC controller into the wall outlet. Replace the cover of the battery box. 10. You may have to press the RED button to silence the PUMP alarm.
While the pumps are active, water will come out of the 1/8” hole located on the top of the main pump and the 3/16” hole located in the elbow of the backup pump. This is normal. The holes are needed to prevent an air lock within the system. DO NOT obstruct the holes or an air lock may prevent the system from activating.




You can receive technical support, parts or service information by calling Glentronics, Inc. at 800-991-0466, option 3, or by visiting the website at www.basementwatchdog.com Send your unit to the following address for repairs:
7 POSITIVE
NEGATIVE
Glentronics, Inc. 645 Heathrow Drive, Lincolnshire, IL 60069
Lift the float within the cage with a pencil or other non-metallic item and let it drop. The
POST


Description Part No.
1/3 HP AC sump pump BW1033-GL Caged dual float switch with piggyback controller BWC2 Emergency backup pump 1011004 Emergency control unit BWE-CONT “Y” PVC pipe fitting 1120007 Support bracket for backup pump 1121003 Battery cap with hole for the fluid sensor 1125000 Charger for backup pump 1015003 Backup dual float switch 1020009 Backup pump locking screw (#12 x 1/2” pan head)* 1100018 1-1/4” check valve for backup pump* 1141000 1-1/2” check valve for primary pump* 1141001 No-hub stainless steel connectors* 1142000 1-1/2” rubber union* 1142001 2” hose clamp* 1122002 Cable tie* 1122000
*Stock items available in plumbing department
Call 800-991-0466, option 3 to order parts.

Backup Pump Troubleshooting Guide
Read safety warnings & instructions before attempting any repairs or maintenance.
Read safety warnings & instructions before attempting any repairs or maintenance.
Potential Cause THE PUMP WILL NOT START OR RUN Solutions
Potential Cause BATTERY FLUID LOW Solutions
Add distilled water to each cell of the battery The fluid sensor should be inserted into the designated hole on the top of the battery and pushed down This feature cannot be used. Attach the fluid sensor to the positive post of the battery
Pump is not plugged in No AC power Poor power source Locked impeller Defective float switch Defective pump
Plug pump in properly (see instructions) Check circuit breaker or fuse Check circuit line wires, cable and outlet Remove strainer and clear obstruction Replace float switch with new float switch Replace pump with new pump
The battery fluid is low The fluid sensor is installed improperly
Not using a Basement Watchdog battery
Potential Cause BATTERY PROBLEM Solutions
Terminals are corroded Cables are loose Battery is discharged below 25%
Clean terminals and cables Tighten wing nuts Replace battery if power is out. There is only 1 hour of continuous pumping power left. Battery will recharge when power is restored Replace battery
Potential Cause THERMAL PROTECTOR TRIPPING OR NOT FUNCTIONING Solutions
Locked impeller Incorrect power supply Pump running continuously with no water present . .
Remove strainer and clear obstruction Check power supply source and voltage Check float switch
Battery is old or damaged
Potential Cause PUMP STARTS AND STOPS TOO FREQUENTLY Solutions
Potential Cause POWER FAILURE Solutions
Float switches mounted too low Water back flowing from pipe Malfunctioning float switch
Raise both float switches Install or replace check valve Replace float switch with new float switch
None. The backup pump will run off of the battery. Flip the alarm switch to the off position to silence the alarm. Be sure to flip it back to on when the power is restored. Try another outlet, replace the fuse, or reset the circuit breaker
Power outage
An outlet, fuse, or circuit breaker has failed
Potential Cause PUMP WILL NOT SHUT OFF Solutions
The charger is unplugged from the wall or the back of the controller The control unit is receiving less than 110 volts from the outlet
Clogged or frozen discharge Blocked intake strainer One or both of the floats is obstructed and cannot drop down
Clear blockage or thaw frozen line Clear debris from intake strainer
Make sure the power cord is plugged in securely
None, if the utility company has instigated brown outs. Otherwise, reduce the number of other appliances on the circuit
Clear debris from inside the float cage (Loosen nut on top of float, then remove c-clip on bottom of float. Remove debris. Tighten nut on top of float, then replace c-clip on bottom of float.) When reassembling the float, the magnetic strip on the inside of the float should be facing down. Replace float switch with new float switch Replace check valve.
Potential Cause PUMP WILL NOT SHUT OFF Solutions
Backup pump is unplugged
Make sure the pump is securely plugged into the back of the control unit Remove strainer from pump and clean out any debris Replace the pump
Backup pump is clogged Backup pump is broken
Defective float switch Check valve is stuck
Potential Cause INSUFFICIENT OR NO WATER VOLUME Solutions
Potential Cause INSUFFICIENT OR NO WATER VOLUME Solutions
The main AC pump failed because of a power outage . The water was coming into the sump faster than the main pump could evacuate it The float switch on the main AC pump is stuck or defective The main AC pump is broken The main AC pump could not keep up with the inflow of water
None. The backup pump was activated when needed
Check valve on secondary pump will not close and water re-circulates within the system Partially blocked impeller Clogged or frozen discharge pipe Broken or leaking pipe Low power voltage Check valve is stuck
None. The backup pump was activated when needed
Replace the check valve on the secondary pump Remove strainer and clear obstruction Clear blockage or thaw frozen line Repair pipe Check power voltage, wires and cable condition Replace check valve.
Free the float switch on the main pump or replace it Replace the main AC pump
None. The backup pump was activated as needed. If this is a recurring problem, install a higher capacity main pump
The check valve is stuck and the water cannot pass through it The discharge pipe is clogged or frozen and the water cannot pass through it There is a slight chance of false activation if the float switch cord is wrapped around the AC power cord
Potential Cause ABNORMAL SOUND OR VIBRATION Solutions
Replace the check valve
Check valve is broken Blocked intake screen Defective pump
Replace the check valve Clear debris from intake screen Replace pump
Thaw, cleanout the blockage, or replace the discharge pipe
Move the float switch cord away from the AC power cord
Potential Cause ABNORMAL SOUND OR VIBRATION Solutions If the above solutions do not resolve the problem, follow the instructions within this manual to disconnect the system from the outlet and battery terminals, then reconnect the system and push the reset button. If the problem continues, contact customer service.
Check valve is broken Discharge pipe is clogged or frozen
Make sure check valve is functioning, or replace it Clear the discharge pipe

By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.
To the extent permitted by law, this warranty and the remedies set forth are exclusive and in lieu of all other warranties, remedies and conditions, whether oral, written, statutory, express or implied. GLENTRONICS, INC. disclaims all statutory and implied warranties, including without limitation, warranties of merchantability and fitness for a particular purpose and warranties against hidden or latent defects, to the extent permitted by law. GLENTRONICS, INC. will not be liable for any incidental, special or consequential damages for breach of any express or implied warranties on this product. In so far as such warranties cannot be disclaimed, GLENTRONICS, INC. limits the duration and remedies of such warranties to the duration of this express warranty and, AT GLENTRONICS, INC.'s option, the repair or replacement services described below. Some states (countries and provinces) do not allow limitations on how long an implied warranty (or condition) may last, so the limitation described above may not apply to you.
Any and all causes of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be governed by and construed under the laws of the State of Illinois. Any cause of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be filed only in the Circuit Court of the 18th Judicial District, Lake County, Waukegan, Illinois, or in the Northern District of Illinois if filed in Federal Court. The maximum liability for any product described in this warranty shall be the cost of product replacement only.
If any term is held to be illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or impaired.
What is Covered by this Warranty?
GLENTRONICS, INC. warrants to the end purchaser that its pumps, switch and control unit products are free from defective materials and workmanship for the periods indicated below:
All parts and labor (excluding installation) for a period of:
The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.
What is NOT Covered by this Warranty?
This warranty does not cover the cost or value of damaged property, including expressly any property that has been affected by water overflow, seepage or flooding. If GLENTRONICS, INC. determines that a product is deemed defective under this warranty agreement, it will repair or replace the PRODUCT ONLY. GLENTRONICS, INC. will not cover the cost to reinstall the product, nor will GLENTRONICS, INC. pay the cost of having a plumber or contractor repair or replace the product.
GLENTRONICS, INC. will not repair or replace a product that was installed incorrectly. A product shall be considered “installed incorrectly” when it deviates in any way from the instructions described in this manual.
This warranty does not cover product problems resulting from handling liquids hotter than 104 degrees Fahrenheit, handling inflammable liquids, solvents, strong chemicals or severe abrasive solutions; user abuse; misuse, neglect, improper maintenance, commercial or industrial use; improper connection or installation, damages caused by lightning strikes; excessive surges in AC line voltage; water damage to the controller; other acts of nature, or failure to operate in accordance with the enclosed written instructions.
How to Obtain Warranty Service
Within thirty (30) days of the product’s defective performance, the unit must be shipped, freight prepaid, or delivered to GLENTRONICS, INC. to provide the services described hereunder in either its original carton and inserts, or a similar package affording an equal degree of protection. Products not received by GLENTRONICS, INC. at the address indicated below within thirty (30) days of the product’s defective performance will not be considered for warranty service. Products received after two (2) years from the date of purchase, fall outside of the timeframe for warranty service and will not be eligible for warranty service. The product must be returned to GLENTRONICS, INC. for inspection in order to be considered for warranty service. If the product is not returned to GLENTRONICS, INC. or the product is inspected by any person, plumber, contractor or business other than GLENTRONICS, INC., this warranty shall no longer be valid. Prior to defective operation, the unit must not have been previously altered, repaired or serviced by anyone other than GLENTRONICS, INC., or its agent; the serial number on the unit must not have been altered or removed; the unit must not have been subject to accident, misuse, abuse or operated contrary to the instructions contained in the accompanying manual. The dealer's dated bill of sale, or installer’s invoice must be retained as evidence of the date of purchase and to establish warranty eligibility.
Where are Products Sent for Warranty Service?
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
How Can I Obtain More Information?
By calling 800-991-0466.
© 2009, Glentronics, Inc. 1806040 01/20