EN
Addonics Technologies logo
Official user manual

Addonics Technologies RT3S5HEU3

8 pages·212 KB·Computer Hardware·PDF·ENDEFRITNLJA
Addonics Technologies RT3S5HEU3
Table of Contents 20 sections User Guide · RAID Tower III (RT3S5HEU3) · v8.1.11 www.addonics.com · Installing drives into the RAID Tower III · … ShowHide
Page 1 of the Addonics Technologies RT3S5HEU3 user manual — v8.1.11 www.addonics.com
Page 1 · click to enlarge
Page 1

T E C H N O L O G I E S

User Guide

RAID Tower III (RT3S5HEU3)

v8.1.11 www.addonics.com

Technical Support If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at:

Hours8:30 am - 6:00 pm PST Phone: 408-453-6212 Email: http://www.addonics.com/support/query/
Page 2 of the Addonics Technologies RT3S5HEU3 user manual — Installing drives into the RAID Tower III
Page 2 · click to enlarge
Page 2

USB 3.0/2.0 Host Port

Installing drives into the RAID Tower III

1. Be sure the lock on each drive door is in an unlock position. If not, use the key that comes with the Disk Array to unlock the drive door. Pull on the door lever to swing open the drive door all the way.

2. Slide a 3.5” SATA hard drive into the drive slot with the drive connector side facing in. Be sure to orient the hard drive correctly as shown in the yellow label on the inside of the drive door – with drive door swing open at the bottom, the top of the hard drive should face to the right. The drive should slide all the way into the slot with very little resistance. Forcing the drive into the slot will cause drive damage or permanent damage to the Disk Array.

Individual Drive Bay Door

Drive Power & Activity LED for Each Drive Bay

3. Once the drive is all the way into the drive slot, close the door all the way till the drive door latch securely. This will engage power and data connection with the hard drive. The LED lit for the drive slot should lit if the Disk Array already powered on. You may lock the drive door with the key

Insert Hard Drives with Top Facing Right

4. To remove the hard drive from the Disk Array, simply follow the step 2 – 3 in reverse.

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Show 6 more labels / short text on this page
Back View · Power Jack · eSATA Port · Dip Switch · Door Lock · Main Power LED
Page 3 of the Addonics Technologies RT3S5HEU3 user manual — Installing drives into the RAID Tower III
Page 3 · click to enlarge
Page 3
Addonics Technologies RT3S5HEU3 — Installing drives into the RAID Tower III diagram (page 3)
Fig. 1 · Installing drives into the RAID Tower III
Dip Switch Settings Raid Mode12345 Individual Drive (Factory Default)OFFOFFOFFOFFOFF 0OFFOFFONONON 1 and 10OFFOFFONONOFF 3OFFOFFONOFFOFF 5OFFOFFOFFONOFF CloneOFFOFFOFFONON LargeOFFOFFONOFFON Enable ERR Buzzer FunctionAutoRebuilding to Spare DrivePort Multiplier Mode
Addonics Technologies RT3S5HEU3 — Installing drives into the RAID Tower III diagram (page 3)
Fig. 2 · Installing drives into the RAID Tower III

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

SATA Ports · Buzzer Alarm · RAID Setting Button

Page 4 of the Addonics Technologies RT3S5HEU3 user manual — Error LED Activity LED
Page 4 · click to enlarge
Page 4

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS – Error buzzer function EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M2 – RAID mode 2 M1 – RAID mode 1 M0 – RAID mode 0

1. Error buzzer function is ENABLED (BZS) when dip switch is in OFF position 2. Auto-rebuilding to spare drive is DISABLED (EZ) 3. Individual drive mode is ENABLED (M0~M2)

LED Pin Header

J3 J1

P5 P0 P1 P2 P3 P4 P5 P0 P1 P2 P3 P4

Error LED Activity LED

J1 – Drive Activity LED P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card. P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.

J3 – Error LED P5 – error LED for eSATA host port P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Page 5 of the Addonics Technologies RT3S5HEU3 user manual — Default factory DIP Switch setting:
Page 5 · click to enlarge
Page 5

Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program:

1. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume.

It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.

2. Modify the RAID mode on the 5-port HPM-XA using DIP switch

Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below.

a. Set the DIP switch to factory default setting.

b. Press the RAID setting button with a ball point pen.

c. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset.

d. Power off the system power.

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Page 6 of the Addonics Technologies RT3S5HEU3 user manual — RAID 0 Mode
Page 6 · click to enlarge
Page 6

e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below.

  • All settings on the diagram shows
  • Error buzzer function is ENABLED
  • EZ function is DISABLED.

RAID 0 Mode

Clone Mode

ON

ON

ON

ON

ON

RAID 1& RAID 10 Mode

Large Mode

ON

ON

ON

ON

RAID 3 Mode

Individual Drives Mode

ON

OFF OFF

RAID 5 Mode

ON

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Page 7 of the Addonics Technologies RT3S5HEU3 user manual — Clone Mode
Page 7 · click to enlarge
Page 7

RAID Setting Notes:

RAID 1& RAID 10 Mode

When 2 drives are connected to the HPM-XA, and DIP switch is set to this setting, the 2 drives will be configured as a 2-drive RAID1 array.

When 4 drives are connected to the HPM-XA, the 4 drives will be configured as a 4-drive RAID10 array.

Clone’s action is similar to RAID1. However, all of the hard drives will be mirrored. Clone mode is useful especially when users like to copy data from a source hard drive to the drives connected to the HPM-XA.

Clone Mode

f. Press the RAID setting button with a ball point pen.

g. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed.

h. Verify if the RAID array is detected by the system.

i. If the 5-port HPM-XA is connected to the motherboard onboard SATA, on the CMOS setup utility, the raid array will display as “Addonics H/W RAID5” if setup as a RAID5 array.

j. If the 5-port HPM-XA is connected to an eSATA host controller card, on the RAID BIOS, the raid array will display as “Addonics H/W RAID0” if setup as a RAID0 array.

k. If booted into Windows, in Disk Drives under Device Manager, the raid array will display as “Addonics H/W LARGE” if setup as a LARGE array.

l. Once raid array is verified, you can set the buzzer either ON or OFF.

www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Page 8 of the Addonics Technologies RT3S5HEU3 user manual — CONTACT US
Page 8 · click to enlarge
Page 8

Notes on Spare Drives using the Easy RAID Setting (EZ)

When EZ is function is ENABLED, the auto-rebuilding to spare drive is automatic.

The degraded RAID group will start rebuilding automatically by using the existing spare drive.

* Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required.

A. Which port acts as a spare drive? The last drive will automatically become the spare drive.

For a 3-drive RAID5 with spare: Drives connected to SATA ports 1~3 belong to the active RAID5 array and drive connected to port 4 is the spare.

For a 4-drive RAID10 with spare: Drives connected to SATA ports 1~4 belong to the active RAID10 array and drive connected to port 5 is the spare.

For a 2-drive RAID1 with spare: Drives connected to SATA ports 1& 4 belong to the active RAID1 array and drive connected to port 5 is the spare.

B. When will rebuild action start? • When the raid fails and EZ is enabled, the HPM-XA will automatically rebuild the RAID group using the spare.

  • When the raid fails and EZ is disabled, the HPM-XA will NOT rebuild the raid group unless you install a good drive to replace the failed drive.

CONTACT US

www.addonics.com Phone: 408-573-8580 Fax: 408-573-8588 Email: http://www.addonics.com/sales/query/

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Addonics Technologies RT3S5HEU3

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Addonics Technologies RT3S5HEU3

Be the first to ask — other owners or our team will answer.

Original document

Addonics Technologies RT3S5HEU3 manual PDF

8 pages·212 KB·Computer Hardware·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…