proxicast MSNSwitch
Table of Contents 8 sections Internal Web Sever · ezDevice Smartphone App · Cloud4UIS.com Web Service · Skype · … ShowHide
Page 1 of the proxicast MSNSwitch user manual
Page 1 · click to enlarge
Page 1

Proxicast, LLC 312 Sunnyfield Drive Suite 200 Glenshaw, PA 15116 1-877-77PROXI 1-877-777-7694 1-412-213-2477 Fax: 1-412-492-9386 E-Mail: support@proxicast.com Internet: www.proxicast.com

Controlling the MSNSwitch Tech Note MSNTN01 © Copyright 2019, Proxicast LLC. All rights reserved. Proxicast is a registered trademark and EtherLINQ, PocketPORT and LAN-Cell are trademarks of Proxicast LLC. All other trademarks mentioned herein are the property of their respective owners.

proxicast MSNSwitch diagram (page 1)
Fig. 1
proxicast MSNSwitch diagram (page 1)
Fig. 2
proxicast MSNSwitch diagram (page 1)
Fig. 3
Page 2 of the proxicast MSNSwitch user manual — Document Revision History:
Page 2 · click to enlarge
Page 2

Document Revision History:

Date Comments Jan. 2, 2020 Updated to include model UIS-622b Aug. 1, 2019 First release This TechNote Applies Only to MSNSwitch Models: UIS-622b, UIS-522b, UIS-523f, UIS-523g, UIS-523i, UIS-523j, UIS-523k and UIS-523e Introduction The MSNSwitch from Mega System Technologies, Inc ("MegaTec") is designed to automatically power-cycle any AC powered device when Internet connectivity is lost. Either of its AC power outlets can also be reset manually or via scheduled actions. There are 7 ways to access and control the functionality of the MSNSwitch:

1. The MSNSwitch’s internal web server screens 2. ezDevice smartphone app 3. Cloud4UIS.com web service 4. Skype 5. Google Hangouts 6. A REST-ful API for HTTP commands 7. The Netility utility software NOTE: Support for the ezDevice app and Cloud4UIS.com web service was added in MSNSwitch firmware

version MNT.9319 (04/24/2019). If your MSNSwitch is running older firmware, please see the Updating Firmware section on page 15. NOTE: Support for the ezDevice app and Cloud4UIS service is Disabled in the MSNSwitch by default.

You must use the MSNSwitch’s internal web server to enable this function under the Network menu.

Page 3 of the proxicast MSNSwitch user manual
Page 3 · click to enlarge
Page 3
proxicast MSNSwitch diagram (page 3)
Fig. 4
Page 4 of the proxicast MSNSwitch user manual — Internal Web Sever
Page 4 · click to enlarge
Page 4

1. Internal Web Sever Full access to all of the MSNSwitch’s functionality is available via its internal web server pages. To access the web server, enter the MSNSwitch’s IP address into any web browser. http://<ip-address-of-MSNSwitch> e.g. http://192.168.1.33 The default username for the MSNSwitch is “admin”. The default password for firmware versions prior to MNT.9731 is “admin”. For MNT.9731 and later, the default password is the last 6 characters of the MSNSwitch’s MAC address (upper case). See the MSNSwitch bottom label for the MAC address. If you do not know the IP address of your MSNSwitch, check your DHCP server log or use the Netility utility software to scan for the MSNSwitch (see page 14).

proxicast MSNSwitch — Internal Web Sever diagram (page 4)
Fig. 5 · Internal Web Sever
Page 5 of the proxicast MSNSwitch user manual — ezDevice Smartphone App
Page 5 · click to enlarge
Page 5
2. ezDevice Smartphone App Download and install the free ezDevice app for iOS from the Apple AppStore or for Android from Google Play.
proxicast MSNSwitch — ezDevice Smartphone App diagram (page 5)
Fig. 6 · ezDevice Smartphone App

If possible, connect your smartphone via WiFi to the same LAN as the MSNSwitch. This is the fastest and easiest way to add the MSNSwitch to ezDevice. Launch the ezDevice app and create a new account. This same account information will be used for the Cloud4UIS.com web service (see page 6). Tap Add Device on the top right of the screen. ezDevice will scan your LAN for the MSNSwitch. If found, tap the + icon to add the MSNSwitch. Enter the Device Key printed on the bottom label of the MSNSwitch. Tap Done to return to the main screen. Once the MSNSwitch has been added, return to the main ezDevice screen. Tap the MSNSwitch in the list of devices to change settings.

proxicast MSNSwitch — ezDevice Smartphone App diagram (page 5)
Fig. 7 · ezDevice Smartphone App
proxicast MSNSwitch — ezDevice Smartphone App diagram (page 5)
Fig. 8 · ezDevice Smartphone App
proxicast MSNSwitch — ezDevice Smartphone App diagram (page 5)
Fig. 9 · ezDevice Smartphone App
proxicast MSNSwitch — ezDevice Smartphone App diagram (page 5)
Fig. 10 · ezDevice Smartphone App
Page 6 of the proxicast MSNSwitch user manual — ezDevice Smartphone App
Page 6 · click to enlarge
Page 6

If you cannot connect your phone to your LAN, then choose the Add by Serial Number option under Add Device.

proxicast MSNSwitch — ezDevice Smartphone App diagram (page 6)
Fig. 11 · ezDevice Smartphone App

Follow the instructions on the screen. Remove the LAN cable from the MSNSwitch for 1 second, then replace it. Check that the blue UIS button is flashing. This is “Add Mode” which must be active to manually add the MSNSwitch to ezDevice. Enter the MSNSwitch Serial Number and Device Key when prompted.

Page 7 of the proxicast MSNSwitch user manual — Cloud4UIS.com Web Service
Page 7 · click to enlarge
Page 7
3. Cloud4UIS.com Web Service Open the Cloud4UIS.com web site using any web browser: http://Cloud4UIS.com If you do not yet have an account, create one on the site. If you previously created and account using ezDevice, use the same login credentials for Cloud4UIS.com. The Cloud4UIS service is free. If you used ezDevice to add devices, they will appear in your Cloud4UIS account automatically.
proxicast MSNSwitch — Cloud4UIS.com Web Service diagram (page 7)
Fig. 12 · Cloud4UIS.com Web Service

If you are adding a device for the first time, click the vertical dot icon

in the upper right corner and then select

to open the Add Device screen.

proxicast MSNSwitch — Cloud4UIS.com Web Service diagram (page 7)
Fig. 13 · Cloud4UIS.com Web Service

the Add icon

Page 8 of the proxicast MSNSwitch user manual — Cloud4UIS.com Web Service
Page 8 · click to enlarge
Page 8

The Add Device screen works the same as it does in the ezDevice smartphone app. If your PC is in the same LAN as the MSNSwitch, you will be able to select it from the list. If your MSNSwitch is not shown, manually enter its serial number to proceed.

proxicast MSNSwitch — Cloud4UIS.com Web Service diagram (page 8)
Fig. 14 · Cloud4UIS.com Web Service

See the ezDevice section on page 4 for instructions on completing the device add procedure. Devices added through Clolud4UIS.com will also be automatically synchronized with the ezDevice app.

Page 9 of the proxicast MSNSwitch user manual — Skype
Page 9 · click to enlarge
Page 9
4. Skype In the MSNSwitch’s web interface, select the Skype menu and enable the Skype function.
proxicast MSNSwitch — Skype diagram (page 9)
Fig. 15 · Skype

Click the Auto Rebooter link to add the Auto Rebooter robot service to your Skype contacts.

proxicast MSNSwitch — Skype diagram (page 9)
Fig. 16 · Skype

Click the Get Started button to add Auto Rebooter to your contacts and begin a messaging session.

proxicast MSNSwitch — Skype diagram (page 9)
Fig. 17 · Skype

Click Send Message to begin a messaging session.

Page 10 of the proxicast MSNSwitch user manual — Skype
Page 10 · click to enlarge
Page 10

Type HELP to see the available commands. Type Get My ID to retrieve the security ID required to connect with your MSNSwitch.

proxicast MSNSwitch — Skype diagram (page 10)
Fig. 18 · Skype

Copy the ID from the Skype response and paste it into the ID field of the MSNSwitch’s web interface. Click ADD to save the settings. In Skype, enter the command Show My Devices and press Enter. The response will be a menu of your devices and actions you can take. Click any of the menu buttons for more actions.

proxicast MSNSwitch — Skype diagram (page 10)
Fig. 19 · Skype
Page 11 of the proxicast MSNSwitch user manual — Google Hangouts
Page 11 · click to enlarge
Page 11

5. Google Hangouts You must first have a Google Hangouts or Gmail account for yourself. You must create a second Google account that the MSNSwitch will use (a unique account for each MSNSwitch you have). In the MSNSwitch’s web interface, select the Hangouts menu and enable the Hangouts function. Enter Google credentials for the account you created for the MSNSwitch. In the Add Contact Accounts field, enter all of the Google accounts which will be permitted to interact with and control this MSNSwitch. Click Apply to save the settings. Check the top of the Hangout tab to ensure that the MSNSwitch was successfully able to log into Hangouts. Click the Send Test Message button to send a message to the contact

proxicast MSNSwitch — Google Hangouts diagram (page 11)
Fig. 20 · Google Hangouts

Open your Google Hangouts account and there should be a test message from your MSNSwitch.

proxicast MSNSwitch — Google Hangouts diagram (page 11)
Fig. 21 · Google Hangouts

Type HELP to see the full list of available commands.

Page 12 of the proxicast MSNSwitch user manual — REST API
Page 12 · click to enlarge
Page 12
6. REST API Basic functions of the MSNSwitch can be controlled through a series of HTTP Packet Requests. Control an Outlet Packet Request: "GET" "HTTP/1.1"CRLF "Host:" CRLF "Keep-Alive: 300"CRLF "Connection: keep-alive"CRLF "Authorization:Base" CRLFCRLF ;auth:encoded account(username:password) with base-64 Request Description: Target: “/cgi-bin/control.cgi?” Action: target=;

0 means UIS, 1 means outlet 1, 2 means outlet 2, 3 means outlet all control=;

0 means off, 1 means on, 2 means switch (i.e. from On → Off, or from Off → On), 3 means reset (Outlet only) Packet Response: XML format: "" "" “”{OUTLET1_STATUS}”,”{OUTLET2_STATUS}”” "”{UIS_STATUS}”” "" XML Description: OUTLET1_STATUS / OUTLET2_STATUS / UIS_STATUS

0 means off 1 means on The action can also be initiated via a simple HTTP URL using control2.cgi: URL: http://<IP-of-MSNSwitch>/cgi-bin/control2.cgi?<action>&user=admin&passwd=1234

Page 13 of the proxicast MSNSwitch user manual — REST API
Page 13 · click to enlarge
Page 13

Example: To force outlet #1 to reset: http://<ip-of-MSNSwitch>/cgi-bin/control.cgi?target=1&control=3&user=admin&passwd=1234 XML Result: 1,1 0

Get the Status of the MSNSwitch Request: Target: “/xml/outlet_status.xml” XML format: "" "" “”{SITE1}”,”{SITE2}”,”{SITE3}”,”{SITE4}”,”{SITE5}”” “”{C1_S}","{C2_S}","{C3_S}","{C4_T}","{C5_S}”” “”{O1_S}","{O2_S}”” “”{S1_L}”,”{S2_L}”,”{S3_L}”,”{S4_L}”,”{S5_L}”” “”{U_S}”” “”{G_T1}”” “”{G_T2}”” “” XML Description: SITE: (n:number)

stringSite <n> IP Address. C<n>_S: (n:number)
digit(unitmillisecond): Site <n> response timing. O<n>_S: (n:number)
digit0 means off, 1 means on. S<n>_L: (n:number)
digitPercent of ping lost. uis_fun:
digit0 means off, 1 means on. G_T<n>: (n:number)
digit0 means None, 3 means All, 1 means Outlet1, 2 means Outlet2
Page 14 of the proxicast MSNSwitch user manual — REST API
Page 14 · click to enlarge
Page 14

Example: To get system status: http://admin:1234@<ip-of-MSNSwitch>/xml/outlet_status.xml XML Result: Google,Yahoo,Bing,Ask.com,Router,, 172.217.15.68,98.138.219.232,204.79.197.200,151.101.2.114,192.168.0.1,null,null 30,46,29,29,5,-1,-1 1,1,0,0,0,0,0 3,3,2,0,0,0,0 1,1 0 0,0 3,3,3,3,3,3,3

Get Last Heartbeat Time URL: http://<IP-of-MSNSwitch>/cgi-bin/heartbeat.cgi?user=admin&passwd=1234 Response: XML format: "" "" “”YYYY/MM/DD HH:MM”” “"

Example: http://<IP-of-MSNSwitch>/cgi-bin/heartbeat.cgi?user=admin&passwd=1234 XML Result: 2019/08/01 04:45

Page 15 of the proxicast MSNSwitch user manual — Netility Utility
Page 15 · click to enlarge
Page 15

7. Netility Utility MegaTec provides a software utility for Windows and MAC called Netility that scan your LAN for compatible devices and allows you to change some configuration settings and upgrade firmware without accessing the internal web server pages. Download and install the Netility utility (Windows or MAC) from the www.MSNSwitch.com web site’s Download page. Connect the MSNSwitch to the same Ethernet LAN as your PC. Open Netility and it will scan the LAN for any MegaTec devices and list them in its main window.

proxicast MSNSwitch — Netility Utility diagram (page 15)
Fig. 22 · Netility Utility

The Network Settings button allows you to configure the IP address and related network parameters of the MSNSwitch as well as set the password. The Launch Web User Interface will open the MSNSwitch’s internal web server in your default browser.

proxicast MSNSwitch — Netility Utility diagram (page 15)
Fig. 23 · Netility Utility
Page 16 of the proxicast MSNSwitch user manual — Updating Firmware
Page 16 · click to enlarge
Page 16

8. Updating Firmware Download the latest MSNSwitch firmware from the Download page at: http://www.MSNSwitch.com Be sure to download the correct file for your MSNSwitch model. Also download and review the firmware Release Notes for important information on the changes and new features. MSNSwitch firmware is delivered as a compressed .ZIP file – extract the .BIN file from the zip archive. The .BIN file is the actual firmware image file you need to use. Using the Web Interface Log into the MSNSwitch’s web interface and select the Save/Upgrade menu. Click the Choose File button to locate the .BIN file you downloaded above. Then click the Apply button to begin the update process. Do not power off the MSNSwitch or remove its Ethernet connection until the process is complete. Once the upgrade is complete and the web page refreshes to show the new firmware version number, we strongly recommend performing a factory reset from this screen to ensure that all new firmware parameters are properly initialized. You should also clear your web browser cache, then reconfigure your MSNSwitch as needed.

proxicast MSNSwitch — Updating Firmware diagram (page 16)
Fig. 24 · Updating Firmware

Using Netility Launch the Netility software (see page 14). Select the device you wish to upgrade and click the Firmware Update button. Select the .BIN file downloaded earlier and begin the firmware update process.

Page 17 of the proxicast MSNSwitch user manual — Updating Firmware
Page 17 · click to enlarge
Page 17

Do not power off the MSNSwitch or remove its Ethernet connection until the process is complete. Once the upgrade is complete and the web page refreshes to show the new firmware version number, we strongly recommend performing a factory reset from this screen to ensure that all new firmware parameters are properly initialized. You should also clear your web browser cache, then reconfigure your MSNSwitch as needed.

# # #

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the proxicast MSNSwitch

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the proxicast MSNSwitch

Be the first to ask — other owners or our team will answer.