Hook the tabs on the N-8650DS's upper side into the panel mount frame's slots, fit them into place, then secure the both bottom sides with a screw.
IP DOOR STATION N-8650DS


Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
Attach the N-8650DS to the YS-13A Wall-mount box installed on a wall.
detach the panel mount frame. (Refer to Step 1 in the previous section.)
Designed to connect to the IP network, the N-8650DS is an indoor use door station featuring high quality hands-free conversation. It is equipped with 1 contact input and 5 contact outputs, allowing connections to a sensor, electronic lock, and other external equipment. The N-8650DS can be mounted either flush in a wall or on a wall by using the designated mounting box.

Mount the panel mount frame to the YC-150 Back box or 3- gang electrical box installed in a wall, then attach the N- 8650DS to the panel mount frame.
8650DS's bottom, then detach the panel mount frame.
Machine screw M4 x 20 (accessory)
frame to the YC-150 or electrical box.
The N-8650DS comes with 2 types of screws: machine screw M4 x 20 and UNC No.6-32 x 20. Use the M4 x 20 screw.

Hook the tabs on the N-8650DS's upper side into the panel mount frame's slots, fit them into place, then secure the both bottom sides with a screw. (Refer to Step 2 in the previous section.)
6-φ4.5 (for wall mounting) 4-M4 (for N-8650DS mounting)

YC-150 Back box or 3-gang electrical box
Machine screw M4 x 20 (accessory)
The N-8650DS comes with 2 types of screws: machine screw M4 x 20 and UNC No.6-32 x 20. For the electrical box provided with unified threads, use the oval head combination screws UNC No.6-32 x 20.

Contact output 1 (brown)
Contact output 2 (red)
Contact output 3 (orange)
To an indicator or other external equipment [Specifications] Open collector output Withstand voltage: 30 V DC Max. control current: 50 mA
Contact output 4 (yellow)
Contact output COM (purple)
To an electronic lock or other external equipment* [Specifications] Relay contact output Withstand voltage: 30 V DC Max. control current: 500 mA
Contact input HOT (gray)
Contact input COM (white)
To a switch, sensor, or other external equipment [Specifications] No-voltage closed contact input. Open voltage: 5 V DC Short-circuit current: 10 mA or less
To external speakers (8 Ω, 0.6 W or more)
* Connection example (When using a 24 V DC relay)
GND
Network connection AC adapter connection
short-circuit.
Can be connected to a network of 10BASE-T/100BASE-TX in auto-negotiation. Use a UTP category 5 or more straight through cable with an RJ-45 connector for this connection.