3. Attach the N-8650DS to the panel mount frame.

Hook the tabs on the N-8650DS's upper side into the panel mount frame's slots, fit them into place, then secure the both bottom sides with a screw.

INSTALLATION MANUAL

IP DOOR STATION N-8650DS

TOA Electronics Ip Door Station — INSTALLATION MANUAL diagram (page 1)
Fig. 1

1. SAFETY PRECAUTIONS

  • Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
  • Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.
  • After reading, keep this manual handy for future reference.
TOA Electronics Ip Door Station — 1. SAFETY PRECAUTIONS diagram (page 1)
Fig. 2

3.2. On-Wall Mounting

Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.

Attach the N-8650DS to the YS-13A Wall-mount box installed on a wall.

  • Use the dedicated AC adapter or its equivalent for the unit. Note that the use of other adapter may cause a fire.
1. Loosen the screw on the N-8650DS's bottom, then

detach the panel mount frame. (Refer to Step 1 in the previous section.)

2. GENERAL DESCRIPTION

2. Mount the panel mount frame to the back box.

Designed to connect to the IP network, the N-8650DS is an indoor use door station featuring high quality hands-free conversation. It is equipped with 1 contact input and 5 contact outputs, allowing connections to a sensor, electronic lock, and other external equipment. The N-8650DS can be mounted either flush in a wall or on a wall by using the designated mounting box.

TOA Electronics Ip Door Station — 2. GENERAL DESCRIPTION diagram (page 1)
Fig. 3

3. WALL MOUNTING

3.1. In-Wall Mounting

Mount the panel mount frame to the YC-150 Back box or 3- gang electrical box installed in a wall, then attach the N- 8650DS to the panel mount frame.

1. Loosen the screw on the N-

8650DS's bottom, then detach the panel mount frame.

Machine screw M4 x 20 (accessory)

2. Mount the panel mount

frame to the YC-150 or electrical box.

The N-8650DS comes with 2 types of screws: machine screw M4 x 20 and UNC No.6-32 x 20. Use the M4 x 20 screw.

TOA Electronics Ip Door Station — 3.1. In-Wall Mounting diagram (page 1)
Fig. 4 · 3.1. In-Wall Mounting
3. Attach the N-8650DS to the panel mount frame.

Hook the tabs on the N-8650DS's upper side into the panel mount frame's slots, fit them into place, then secure the both bottom sides with a screw. (Refer to Step 2 in the previous section.)

N-8650DS

6-φ4.5 (for wall mounting) 4-M4 (for N-8650DS mounting)

TOA Electronics Ip Door Station — N-8650DS diagram (page 1)
Fig. 5

YC-150 Back box or 3-gang electrical box

Machine screw M4 x 20 (accessory)

The N-8650DS comes with 2 types of screws: machine screw M4 x 20 and UNC No.6-32 x 20. For the electrical box provided with unified threads, use the oval head combination screws UNC No.6-32 x 20.

Unitmm
Show 7 more labels / short text on this page
Panel mount frame · Screw hole · Screw · Accessory screws · N-8650DS's bottom · [YS-13A dimensional drawing] · Accessory screws
Page 2 of the TOA Electronics Ip Door Station user manual — 24 V DC
Page 2 · click to enlarge
Page 2

4. WIRING

Connection to an external equipment

Contact output 1 (brown)

Contact output 2 (red)

Contact output 3 (orange)

To an indicator or other external equipment [Specifications] Open collector output Withstand voltage: 30 V DC Max. control current: 50 mA

Contact output 4 (yellow)

Contact output COM (purple)

To an electronic lock or other external equipment* [Specifications] Relay contact output Withstand voltage: 30 V DC Max. control current: 500 mA

Contact input HOT (gray)

Contact input COM (white)

To a switch, sensor, or other external equipment [Specifications] No-voltage closed contact input. Open voltage: 5 V DC Short-circuit current: 10 mA or less

To external speakers (8 Ω, 0.6 W or more)

* Connection example (When using a 24 V DC relay)

24 V DC

GND

Network connection AC adapter connection

short-circuit.

Can be connected to a network of 10BASE-T/100BASE-TX in auto-negotiation. Use a UTP category 5 or more straight through cable with an RJ-45 connector for this connection.

Connect the AC adapter. Use the AD-1210P/1215P (option) or equivalent. As for the usable adapter, consult your TOA dealer.

  • Power supply connection ( or )
  • The following 2 methods are available for supplying power to the station.
  • From a DC 12 V AC adapter
  • From an IEEE802.3af compliant PoE switching hub (For connection, refer to the instruction manual supplied with the switching hub.)
5. ACCESSORIES UNC No.6-32 x 20 4 Machine screw M4 x 20 4

LAN coupler 1

TOA Electronics Ip Door Station — 24 V DC diagram (page 2)
Fig. 6

TOA Electronics Europe GmbH Suederstrasse 282, 20537 Hamburg, Germany

Show 12 more labels / short text on this page
N-8650DS rear · Contact output (blue) · Contact output (blue) · Speaker cable (black) · LAN coupler (accessory) · Speaker cable (black) · Diode · External power supply · Relay · + - · Contact output (blue) · Contact output (blue)

Ask about the TOA Electronics Ip Door Station

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the TOA Electronics Ip Door Station

Be the first to ask — other owners or our team will answer.

Original document

TOA Electronics Ip Door Station manual PDF

2 pages·134 KB·Intercom·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…