NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice.
NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc.
NEAX and Dterm are registered trademarks of NEC Corporation.
All other brand or product names are or may be trademarks or registered trademarks of, and are used to identify products or services of, their respective owners.
MS-DOS and Microsoft are registered trademarks of Microsoft Corporation. Microsoft Windows 95 and Windows NT are trademarks of Microsoft Corporation.
NEC America, Inc.
Printed in the U.S.A
Copyright 2000




1 2 3 4 5 6 7 8 PAGE No.


Figure 2-1 Software Structure in the OAI System 5 Figure 2-2 Concept of MSF 6 Figure 2-3 Concept of TMF 7 Figure 2-4 Concept of ETF 7 Figure 2-5 Concept of ACF 8 Figure 2-6 Concept of FLF 8 Figure 2-7 Concept of TCF 9 Figure 2-8 Concept of KTF 9 Figure 2-9 Concept of NTF 10 Figure 2-10 Concept of SCF 10 Figure 2-11 Concept of RCF 11 Figure 2-12 Concept of MRF 11 Figure 2-13 Concept of ATF 12 Figure 2-14 IP Single System Configuration 15 Figure 2-15 IP Dual System Configuration 16 Figure 3-1 Cable Connections Between OAI System and External Computer 20 Figure 4-1 Configuration of Commands of the NEAX2400 IMX OAI System 26 Figure 4-2 Interrelation among OAI System Commands 28 Figure 5-1 Network Configuration of OAI systems 82 Figure 6-1 Flow of Maintenance Works 87 Figure 6-2 Flow of Fault Repair 92 Figure 6-3 Flow of Diagnosis out of System Messages 93
Page iv Revision 1.0
Figure Title Page

Table 1-1 Configuration of This Manual 1 Table 1-2 Related Reference Manual 2 Table 2-1 Interface Conditions of the Circuit Card 17 Table 4-1 OAI System Command Table List 27 Table 4-2 Supplementary Service Codes 42 Table 5-1 OAI Software and System Data 83 Table 6-1 Relationship between System Messages and Alarm Lamps on TOPU 88 Table 6-2 System Messages of OAI System 89 Table 6-3 Error Code 90 Table 6-4 Repairing Procedure for TCP/IP Link Failure (Message “4-R”) 94 Table 6-5 Repairing Procedure for TCP/IP Link Failure (Message “26-V”) 94
Page v Revision 1.0
Table Title Page

This page is for your notes.
LIST OF TABLES ND-70895 (E) Page vi Revision 1.0

1. General
This manual describes the outline, installation procedure/installation tests, and various phases of maintenance work of an OAI (Open Application Interface) system which realizes the NEAX2400 IMX and a computer system.
2.1 Configuration of This Manual
Configuration of this manual is shown in Table 1-1.
Table 1-1 Configuration of This Manual

INTRODUCTION How to Follow the Manual
2.2 Related Reference Manual
The installation tasks for the NEAX2400 IMX OAI System consist of those related to the NEAX2400 IMX system and those related to the OAI functions. Since this manual describes the tasks pertaining to the OAI functions, it must be used together with the following manuals that describe tasks pertaining to the NEAX2400 IMX itself when performing tasks pertaining to the NEAX2400 IMX OAI System.
Table 1-2 Related Reference Manual

1. General
This chapter describes the concept, functions, and configuration of the NEAX2400 IMX OAI System. Before performing installation and/or maintenance of the NEAX2400 IMX OAI System, read this chapter carefully.
The contents of Chapter 2 are outlined below.
Explains the outline of the OAI system
Explains the configuration of the OAI system
Explains the conditions for interface with external computer, and use of the related circuit cards

SYSTEM OUTLINE System Outline
2.1 OAI (Open Application Interface) System
2.2 Software Structure in the OAI System
The software structure in the OAI system is shown in Figure 2-1. So far, the software structure of the NEAX2400 IMX is generally categorized into three major blocks: Input Processing Block, Internal Processing Block, and Output Processing Block. When the Input Processing Block detects a call, the Internal Processing Block analyzes and identifies the call. In accordance with the result of this processing, the Output Processing Block executes required switching operations, controlling of lamps/keys, etc. To meet these processing requirements, a conventional arrangement is made every time a request for the application software arises. The modules of the Input Processing Block and the Output Processing Block are replaced with those corresponding to such a request. However, in the case of the OAI system, each unit function to be made available for the computer in the Input Processing Block and the Output Processing Block is defined as a facility (each slant lined portion in Figure 2-1) in advance, so that each of these facilities may be directly controlled by the external computer through the OAI interface. For example, the key information input by processing of key receiving is not processed within NEAX2400 IMX, but is analyzed by the external computer. As a result of this processing by the external computer, all the related messages are shown on a digital display and a lamp display at corresponding terminals. In other words, the OAI interface has released the function of the conventional internal processing to the external computers.


Processing by External Computer portion is the unit function (partial) to be released by the OAI system.
Equivalent to the internal processing of the NEAX2400 IMX
Figure 2-1 Software Structure in the OAI System

SYSTEM OUTLINE System Outline
2.2.1 Facilities
Each of the unit functions of the NEAX2400 IMX, such as switch control function, terminal control function, etc., that can be controlled by the application of the computer is referred to as “facility”. The facilities can be categorized in two kinds as per the operating pattern; one is “Provider Facility” and the other is “Performer Facility”.
Each of the main facilities is outlined in the following.
(a) Terminal Mode Set Facility (MSF) With a specific key depressed on a terminal, this facility sets terminal mode. When terminal mode is set by this facility, a communication path is set up between the terminal and the AP on the computer. (Figure 2-2)

Figure 2-2 Concept of MSF

(b) Terminal Multiple Information Transfer Facility (TMF) This facility executes batch transfer of dial number information entered from a terminal, card information provided from the card reader, etc. to the AP. (Figure 2-3)

Figure 2-3 Concept of TMF
(c) Call Event Transfer Facility (ETF) This facility edits the detailed data (call duration, etc.) pertaining to calls at terminals accommodated in the NEAX2400 IMX, and provides the edited information to the computer. (Figure 2-4)

Figure 2-4 Concept of ETF
System Outline

SYSTEM OUTLINE System Outline
(d) Authorization Code Facility (ACF) Upon accepting a connection request and/or a service request from a terminal, this facility transfers the ID code of that specific terminal to the AP and also executes either connection processing or connection restricting processing in accordance with the restriction class information returned from the computer. (Figure 2-5)

Figure 2-5 Concept of ACF
(e) Free Location Facility (FLF) This facility establishes the correspondence between the extension number allocated to a terminal and the user’s unique ID code in accordance with the number conversion information provided from the AP. (Figure 2-6)

Figure 2-6 Concept of FLF

(a) Terminal Control Facility (TCF) This facility controls the LCD, LED, etc. on a terminal concerned as per a control order provided by the AP. It also activates the KTF, NTF, and CRF upon receiving a data read request provided from the AP. (Figure 2-7)

Figure 2-7 Concept of TCF
(b) Key Code Transfer Facility (KTF) When a terminal concerned is on the terminal mode, this facility transfers the key code information from that specific terminal to the AP. (Figure 2-8)

Figure 2-8 Concept of KTF
System Outline

SYSTEM OUTLINE System Outline
(c) Dial Number Transfer Facility (NTF) When a terminal concerned is on the terminal mode, this facility transfers the dialed number information from that specific terminal to the AP. (Figure 2-9)

Figure 2-9 Concept of NTF
(d) Switch Control Facility (SCF) This facility executes the processing of an outgoing connection or of releasing the connection between a terminal and another in accordance with the connection control information provided from the AP. (Figure 2-10)

Figure 2-10 Concept of SCF

(e) Restriction Control Facility (RCF) This facility changes the restriction class of a terminal concerned in accordance with a directive given by the AP. The restriction class changing can be made on the basis of each terminal, each group, or each system. (Figure 2-11)

Figure 2-11 Concept of RCF
(f) Terminal Mode Reset Facility (MRF) With a direction received from the AP or a specific key depressed on a terminal, this facility resets terminal mode. When terminal mode is reset by this facility, the current communication path (terminal mode status) is released. (Figure 2-12)

Figure 2-12 Concept of MRF
System Outline

SYSTEM OUTLINE System Outline
(g) Application Language Transfer Facility (ATF) With a direction received from the AP or a specific key depressed on a terminal, this facility sends out the APL information input from an OAI terminal to the AP. (Figure 2-13) The system does not care the contents of the APL information at all.

Figure 2-13 Concept of ATF

2.2.2 Join of Facilities and Application
(a) Set-up of Association A communication path is to be opened so that the AP can communicate with the facility.
(b) Opening of Facility The facility that the AP uses is to be declared to the NEAX2400 IMX, and then the AP and the declared facility are joined.
2. Set-up of Association and Opening of Facility Association is set up by activation from the AP first, and then the association is released along with the stop of the AP. Without this association, the AP cannot communicate with the facility and cannot control the facility, either. Then, the facility must be opened so as to allow the AP to communicate with the facility through the communication path opened by setting up of the association. Opening of facility is executed on each facility basis. As a result of the above procedure, the AP becomes able to freely control each of the facilities of the NEAX2400 IMX, and a variety of applications can be programmed on the computer.
2.2.3 Cope of Application in changeover of CPU System
Associations established between NEAX2400 IMX and External computer are released when changeover of CPU system executes. Therefore each application program cap must set up Association again after changeover of CPU system.
System Outline

SYSTEM OUTLINE System Configuration
The OAI System can be implemented in the Built-in Type configuration, with which the IP is built in the CPU of the NEAX2400 IMX. The configuration of the NEAX2400 IMX OAI System is as follows.
Single CPU configuration (Figure 2-14)
Dual CPU configuration (Figure 2-15)
External Computer Interface Circuit
Provided with External LAN cable connected from the PBX
OAI System · Built-in CPU

SYSTEM OUTLINE System Configuration

CPU Central Processing Unit (NEAX2400 IMX) CPR RAM: Built in Data Memory
Dterm Digital Multifunction Terminal Dterm Series E
ETHER Ethernet Controller PZ-PC19 Ethernet + TCP/IP protocol con- trol

SYSTEM OUTLINE System Configuration

CPU Central Processing Unit (NEAX2400 IMX) CPR RAM: Built in Data Memory
Dterm Digital Multifunction Terminal Dterm Series E
ETHER Ethernet Controller PZ-PC19 Ethernet + TCP/IP protocol con- trol

SYSTEM OUTLINE Interface with External Computer
4.1 Conditions for Interface with External Computer
The circuit card for interface with the external computer (general-purpose information processing equip- ment), and the interface conditions are shown in Table 2-1.
Table 2-1 Interface Conditions of the Circuit Card
ETHER
(Class A, B, C is available Note)
Data Transfer Speed 10 Mbps
Number of Interface Ports 1 port/card (16 logical channels/port)

This page is for your notes.

1. General
This chapter explains the installation procedure for OAI System of NEAX2400 IMX.

INSTALLATION PROCEDURE Cable Connections with External Computer
This section explains cable connections between the NEAX2400 IMX OAI System and the external computer.
2.1 Cable Connections between OAI System and External Computer
The cable connections between the OAI system and the external computer are shown in Figure 3-1.
[PZ-PC19 card (LANI) is used]

00 01 02 03 04 05 06 07 08 09 10 11
12 13 14 15 16 17 18 19 20 21 22 23
00 01 02 03 04 05 06 07 08 09 10 11
Figure 3-1 Cable Connections Between OAI System and External Computer
(a) Connection diagram

3. OAI Software Installation
This section explains the installation procedure for adding the OAI software to the PBX in off-line operation. For more detailed information of program install procedure before the OAI application software install, see “Installation Manual”.
When OAI system is used in the Fusion Network (OAI Terminal Anywhere), link the ACD Option Service Software for “Agent Anywhere” with the above software FD and install it into all the nodes. (valid since the PBX software R8)
ASYD SYS1 INDEX31 - b0~b3: CM mounting capacity Normally assign “04”. Note 1 Note 2 Note 3 INDEX79 - b6=0 (OAI service is in service) Note 1 INDEX207 - b0 (IP in system0), b1 (IP in system1) Assign “1” to the corresponding bit for the IP accommodation. INDEX241- b2=1 (Call Processing Event Notification) Note 1 INDEX241- b3=1 (Details of SCF Error Notification) Note 1
OAI service) to 04H.
This data below are necessary when OAI system is used through the Fusion Network.
ASYDN SYS1 INDEX514- NDM usage INDEX533- FPC of the node that provides VNDM (Normally, assign the FPC of the node that has the IP)
OAI Software Installation · [Operation Procedure]

INSTALLATION PROCEDURE OAI Software Installation
ASYDL SYS1 INDEX512: FPC of the self-node When OAI system is used through the Fusion Network, this data setting is necessary at each node in the network. INDEX513: 01 Hex (LDM usage) INDEX515~518 b0~b7: IP address (Hex) for PBX over external LAN Note 4 INDEX519~522 b0~b7: Subnet Mask (Hex) for PBX over external LAN Note 4 INDEX523~526 b0~b7: Default Gateway Address for External LAN Note 4 (This data is required when the Host is connected via gateway) INDEX864 - b0=1 (Built-in IP is provided) When OAI system is used in the Fusion Network (OAI Terminal Anywhere) [available since the Series 7400 (Release 8) software], assign “1” at the node that has the IP. INDEX864 b1 :Output the system message (4-R) when TCP-IP is normally disconnected. 0/1=Effective/Ineffective

INSTALLATION PROCEDURE Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
The procedure for upgrading OAI System NEAX2400 ICS to NEAX2400 IMX is shown below.
4.1 Up Grading Procedure
“Cable Connections with External Computer”. The TCP Port number of the external computer has to be changed to “60030” for NEAX2400 IMX.

This page is for your notes.

1. General
This chapter explains the commands that are used in the NEAX2400 IMX OAI System. The contents of this Chapter are outlined below.
This section explains the construction of each command.
This section explains the functions, parameters, and operating procedure of each command.

COMMANDS Configuration of Commands for OAI System
2.1 Configuration of Commands
The configuration of the commands in use in the NEAX2400 IMX OAI System is shown in Figure 4-1.
OAI System Operating Commands
Commands for OAI System
LMNO LOAC LOKC DFLN
ASYDL
ASYD
AKYD ARNP ASPA
ASYDN
Figure 4-1 Configuration of Commands of the NEAX2400 IMX OAI System
Commands for Business · Commands

3. Commands
This section explains the commands in used in the OAI System.
3.1 List of Commands
Table 4-1 shows a list of commands in use in the OAI system. As for any command other than those in the list, refer to the Feature Programming Manual and Office Data Specification of the NEAX2400 IMX.
Table 4-1 OAI System Command Table List
AADT Assignment of Announcement/Dictation Trunks
ACNO Assignment of Conversion Number Data
AKYD Assignment of Key Data for Dterm
AMNO Assignment of Monitored Number
AOAC Assignment of OAI Access Code
AOKC Assignment of OAI Key Code
ARNP Note 2 Assignment of Reverse Numbering Plan Data
ASPA Assignment of Specific Attendant Number
ASYDN
Assignment of System Data
DFLN Display of Location Free Numbering
LADT Note 1 List Up of Announcement/Dictation Trunks
LCNO Note 1 List Up of Conversion Number Data
LMNO Note 1 List Up of Monitored Number
LOAC Note 1 List Up of OAI Access Code
LOKC Note 1 List Up of OAI Key Code
omitted.
NEAX2400 IMX.
Commands

3.2 Outline of Commands for OAI System
The interrelation among the commands to be used in the OAI System is illustrated in Figure 4-2.

: Assignment of System Data : Assignment of Reverse Numbering Plan Data : Assignment of Station Data
Figure 4-2 Interrelation among OAI System Commands
AKYD: This command is used to assign the function key codes (For OAI: 34 ~ 47) to the function key
positions of the Dterm.
AOKC : This command is used to assign the meaning of OAI key code assigned by AKYD command.
AOAC : This command is used to assign the access code/operation code for the designated facility.
This command is used only when the Facility Kind (F-KIND) has been set to “3” (Open Appli- cation Interface) by AOKC command.
determined by the application software to be used at each office.
3.3 Items to Be Explained by Each Command
Each command is described by the following items.
Command : The name implies the command and its functions. (1) Functions : This item outlines the command functions. (2) Precaution : This item explains precaution for use of the command. (3) Parameters : This item explains the meaning of the information (parameters) of the data of
assignment/deletion/change/display/list up of the details of that specific data.
COMMANDS Commands

AADT
AADT: Assignment of Announcement/Dictation Trunks
This command is used to assign/delete Announcement Trunks or Dictation Trunks.
When changing the LENS of the currently assigned Announcement/Dictation Trunks, delete the assigned data first by this command, and then change the LENS by Assignment of Trunk Data (ATRK) command. It must be remembered that, if the LENS data are deleted first by ATRK command by mistake, the data currently assigned by this AADT command are automatically deleted.
TYPE : Announcement Trunk (ANT), Dictation Trunk (DCT) NO. : Message Number D : Disconnect Timer (0/1); Valid when TYPE = ANT 0: Impossible (Repeat) 1: Possible (Disconnect by MSGT) MSGT : Message Timer (2 ~ 120 sec., 2-sec. interval when shorter than 30 sec., 8-sec. interval
when longer than 30 sec.) CP : Connection Pattern Note 0: Multiple Connection 1: Single Connection WAIT : Waiting Timer (0~30 sec., 2-sec. interval) Note
CNT : Number of ANT/DCT Trunks assigned or to be assigned (1 ~ 8) RT : Route Number TK : Trunk Number

Announcement/Dictation Trunk Data Assignment Table
MESSAGE NO.
DISCON-
CONNEC-
TRUNK
(NO) MESSAGE
WAITING
NECT TIMER
TION PATTERN
ROUTE NUMBER
TRUNK NUMBER
TYPE (TYPE) ANT/DCT
TIMER (MSGT)
TIMER (WAIT)
NO. OF TRUNKS
(TK) ANT 1 ~ 58 DCT 1 ~ 5
(CP)
(CNT)
(RT)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Disconnect Timer 0 = Impossible 1 = Possible

ACNO
ACNO: Assignment of Conversion Number Data
This command is used to assign/delete the conversion number required for selecting a route on a each route basis.
(a) The data should be assigned to ring-down trunks.
(b) As a conversion number, a monitor number assigned by AMNO command should be set.
RT : External Route Number TN : Tenant Number of Monitored Number MNO : Monitored Number (Max. 5 digits) Note
Monitored Number Assignment: AMNO – Parameter RT – Monitored Number Deletion : AMNO Assignment: ARTD List Up : LCNO Display : ARTD List Up : LRTD

Conversion Number Data Assignment Table
MONITORED NUMBER
EXTERNAL ROUTE NUMBER
(MNO) MAX. 5 DIGITS (Note)
(TN)

AKYD
AKYD: Assignment of Key Data for D term
This command is used to assign/delete/display the function key data, multi-line data or intercom data corresponding to each key on such multi-function telephone terminal as Dterm Series E.
For the details of Dterm data, refer to the description of AKYD command in the Feature Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited only to the items pertaining to the OAI System.
FKY: Function Key (valid for KYI=1) 34= OAI Key 1 35= OAI Key 2 36= OAI Key 3 37= OAI Key 4 38= OAI Key 5 39= OAI Key 6 40= OAI Key 7 41= OAI Key 8 42= OAI Key 9 43= OAI Key 10 44= OAI Key 11 45= OAI Key 12 46= OAI Key 13 47= OAI Key 14 52= Speaker 59= Release

AMNO: Assignment of Monitored Number
This command is used to assign/delete Monitored Numbers.
Monitored Number (MON) is a number of maximum 5 digits consisting of 0 ~ 9, “*” and “#”. Note that, in the case of a hotel system, UCD Pilot Number (STN) is a number of maximum 6 digits, respectively. As NMI value, use a different value for each MON to be assigned.
TN : Tenant Number MNO : Monitored Number (Max. 5 digits) NMI : Monitored Number Index (1 ~ 4095) UCD : Going by UCD when monitor status is not requested from AP 0: Not going by UCD 1: Going by UCD STN : UCD Pilot Number (Max. 5 digits) Note
[In the case of Hotel System]

AMNO
Monitored Number Assignment Table
DESIGNATION OF ADMINISTRATION/
MONITORED
MONITOR STATUS IS NOT REQUESTED FROM
UCD PILOT
MONITORED NUMBER INDEX
TENANT NUMBER
NUMBER
NUMBER
GUEST ROOM (A: FOR ADMINI
(MNO) MAX. 5 DIGITS
(STN) MAX. 5 DIGIT
(NMI) 1 ~ 4095
(TN)
AP (UCD)
G: FOR GUEST
(Note 1)
(Note 1)
ROOM) (Note 2)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Going by UCD when monitored status is not requested from AP :0/1 = Not Going By UCD/Going By UCD.
0/1

AOAC: Assignment of OAI Access Code
This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each service access code of the OAI System.
(a) When setting a minus value (less than 0) to the parameter “OP-CODE”, add “-” (minus symbol) ahead to the value. If the set value is a positive value, it is automatically interpreted to be a positive value even if “+” (plus symbol) is not added ahead of the value.
(b) For assigning OAI access codes, it is necessary to assign the necessary number of digits of OAI access codes by AOKC command in advance to assigning the codes.
OAI-ACC : OAI Access Codes (000 ~ ###) (Max. 3 digits) F-KIND : Facility Kind (1 ~ 15)
When F-KIND = 1, 128 ~ 191 When F-KIND = 2, 192 ~ 255

AOAC
OAI Access Code Data Assignment Table
FACILITY KIND
OPERATION CODE
(MAX 3 DIGITS)
(1/2) (F-KIND)
128 ~ 255 (OP-CODE)
(OAI-ACC)

AOKC: Assignment of OAI Key Code
This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each function key on the Dterm.
(a) The OAI code for which F-KIND = 3 (Open Application Interface) can be assigned is only one per system.
(b) When deleting the Open Application Interface (OAI) key code for which F-KIND = 3 is assigned, it is necessary, in advance to the intended deletion, to delete all the OAI access code data assigned by AOAC.
(c) When OAI key data has been assigned/deleted on basis of a function key by this command, operation of the OAI key is ignored only once immediately after that assignment/deletion or immediately after a system initialization.
KEY-CODE: OAI Key Codes (1 ~ 31) Note 1 F-KIND : Facility Kind (1 ~ 15)
OAI (Terminal Mode Set Facility) 191 (00BF)H: MSF 192 (00C0)H: TMF
OAI (Terminal Multiple Information Transfer Facility) 255 (00FF)H: TMF

AOKC
below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ~ 31
34 35 36 37 38 39 40 41 42 43 44 45 46 47 Not used
follows:

OAI Key Code Data Assignment Table
OPERATION CODE
CHIME CONTROL ON NOR-
OAI KEY CODE
FACILITY KIND
MAL END OF MSF, TMF
(1 ~ 31) (KEY-CODE)
(1 ~ 15) (F-KIND)
(1 ~ 3) (NND) (Note 1)
(128 ~ 255) (OP-CODE) (Note 2)
hand by Assignment of OAI Access Code Data (AOAC) command.

AOKC
Table of Operation Codes
128 (0080): MSF
OAI
191 (00BF): MSF
(Terminal Mode Set Facility)
OAI
255 (00FF): TMF
(Terminal Multiple Information Transfer Facility)

ASPA: Assignment of Specific Access Code
This command is used to assign/delete/display each data which respectively determines what kind of service should be executed and/or which route should be used, etc. when a special access code, C.O. line access code or Tie-Line access code has been dialed.
(a) For the details of special access code data, refer to the description of ASPA command in the Feature Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited only to the items pertaining to the OAI System.
(b) For assigning OAI Dial Number Batch Transfer (SRV = SSCA, SIDA = 69), be sure to set the number of digits (max. 3 digits) of the OAI access code to Necessary Number of Digits (NND).
Specific Access Code Data Assign Table
The Office Data Sheets of this ASPA command are attached only to the pages pertaining to the data to be assigned in the OAI System. Replace these Office Data Sheets with those for ASPA command of the NEAX2400 IMX.
Table 4-2 Supplementary Service Codes
ACCESS
CONNECTION STATUS INDEX
KIND OF SERVICE
CODE (ACC)
(SRV) SERVICE FEATURE INDEX A
(TN)
(CI)
REMARKS
(SIDA)
1 ~ 31 1 ~ 3 DIGITS N/H/B SSCA
SSCA 69 OAI Dial Number Batch Trans- fer (TMF) H Hooking
N Normal

ASYD
ASYD: Assignment of System Data
This command is used to assign System Data 1, 2, and 3.
For the details of the system data, refer to the description of ASYD command in the Office Data Specification for the NEAX2400 IMX.

System Data Assign Table (1)
The Office Data Sheets of this ASYD command are provided only for the data to be assigned in the OAI System. Use these Office Data Sheets together with those for ASYD command of the NEAX2400 IMX.
SYSTEM
SYSTEM
DATA INDEX (INDEX)
DATA (DATA) 00– FF (Hex)
DATA SYSTEM DATA CONTENTS
0/1 BIT
Call Event Transfer Facility (ETF) Call Base Table Save and ETF Ser- vice is provided
0 b6 Fixed to 0
0 b7 Not used
b0 Miscellaneous Timer Counter
Message sending Guard Timer for Message Center Interface.
(00 ~ 1F Hex)
Guard Time after sending data to Message Center:
Time Value Setting is (MTC) × 128 msec.
(When this data is 00 Hex, Timer value is 0 msec.)
Be sure to set “1” when using SSFR (FN = 5, SRID = 0)
MCI Message Waiting Lamp Function
0 b6 Not used 0 b7

ASYD
System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
0 b0 Equipped capacity of the Common Memory (CM): 1 ~ 4 Mbyte
Assign “6” Hex. when FLF Fusion service is used. (Available since the PBX software R8)
Not used 0 b5
Traffic Measurement Indication 0/1 = CCS Indication/Erlang Indication
Timer Internal Between Messages (TCFI) Timer
b2 b1 b2 b1 0 0 = 2 seconds 1 1 = Application Dependent 0 1 = 4 seconds (Standard Assignment) 1 0 = 8 seconds
Display for TCFD 0/1 = MSG/Last input 0 = Normal assignment
SCF(FN = 127) Tone Control 0/1 = Invalid/Valid
0 b5 Not used 0 b6
Traffic Measurement for Terminal and Route Traffic (ATRF) 0/1 = Out/In service

System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
Called Number Display when forwarding to Attendant Console 0/1 : Out/In service
Flashing display of Line Lockout on Attendant Console BLF 0/1 : In service/Out
Route No. Display on Attendant Console
b3 b2 0 0:
b3 b2 0 1:
RT TRK
One digit dialing instead of SHF (DP TEL only) 0/1 : Not required/Required
Priority order for answering via ANSWER key 0 : Priority according to Type of Call 1 : Priority according to the order call termination
Send Warning Tone to interrupted parties when Executive Right of Way service is in operation 0/1 : Required/Not required
Day/Night Mode Change via the ATTCON Handset Jack 0/1: Not required/Required
0 b1 Not used
b2 MW Refresh 0/1 :Not required/Required
b3 Service Module Interface 0/1: Not required/Required
1 b4 Module in which PFT card is mounted PIM (Always assign “11”) 1 b5
0 b6 Not used 0 b7

ASYD
System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
Calling and Intermediate Station Number indication (Dterm and ATTCON) 0/1: Out/In service (Always assign “1”)
Kind of Service Class indication (Dterm) 0/1: Out/In service (Always assign “1”)
0 b2 Not used
Station Number Display with 8-digit Name Display 0/1: Out/In service
0 b4 Fixed to “0”
0 b6 Not used 0 b7
Line Preference Service via AKYD 0/1: Out/In service
0 b1 Not used
0 b3 Not used
Zip tone control at the time of SC F:Monitor connection 0/1: Not to be controlled/To be controlled
Name Display Service for Calling Party Only 0/1: Out/In service Note 1
0 b7 Not used
invalid. Note 2: If, at an office in service with this bit set to “1” (No OAI Service is Provided), the bit value is to be changed
to “0” (OAI Service is Provided).

System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
0 b0 Not used
Message Reminder Service-Key used for Message Deletion (Dterm) 0/1 = # key/* key
b2 Fixed to “0”
TCF (I) : LCD Display Control 0: Top Line 16-digits display control 1: Second Line 16-digits display control
Not used 0 b5

ASYD
System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
b0 No. 0 CPU Mounted Status of IP00/1:Not mounted/Mounted
b1 No. 1 CPU Mounted Status of IP00/1:Not mounted/Mounted

System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
Data Port Chime Control by SCF 0/1: To be controlled/Not to be controlled
Call Status Monitor Facility Notification (SMFN) 0/1: Invalid/Valid
SCF Return Error Detail Notification 0/1: Invalid/Valid
Not used 0 b5
b0 Miscellaneous Timer Counter (MTC)
Value for OAI Host Computer Answer Wait Timer (TC) × (MTC) is to be set.
b4 Timer Class (TC) 0: – 3: 2 sec.6:– 1: 64 msec. 4: 30 sec.7:– 2: – 5: –
When the data is 00 (Hex), the timer value becomes 8 minutes. Note
0 b7 Not used

ASYD
System Data Assign Table (1)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
SCF Call origination from the first party notification 0/1 = Ineffective/Effective
b1 Not used
Access to Announcement trunk is controlled: 0 = by the timer, 1 = by the DAT
Output pattern of INS information by SMFN 0/1: HEX/ASCII
Not used b5

System Data Assign Table (3)
SYSTEM
SYSTEM
DATA (DATA) 00– FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
0/1 BIT
b0 Designation of the initial mode of the card reader 000: PB Sender 100 001: LP Command : Not used 010: – 111 011: Data channel

DFLN
DFLN: Display of Location Free Numbering
This command is used to check the assigned data of Location Free Numbering Service. When this command is activated, the assigned data are displayed on a basis of each designated station number.
The data to be displayed by this command are those assigned from the User Application Processor (UAP) and thus they cannot be assigned by a command.
[Input Parameters] F : Function Kind (0/1) LSTN : Logical Station Number (ID-No. Max. 5 digits) Note 1 TN : Tenant Number Note 2 PSTN : Physical Station Number (Station Number) Note 2

ASYDN: Assignment of System Data in NDM
This command is used to assign system data 1 and 2.
Refer to the following page.

ASYDN
BIT CORRESPONDING
SYSTEM
SYSTEM
DATA (DATA) 00 – FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS (MDATA)
DATA
0/1 BIT
b0 Network Data Memory (NDM) usage. Assign data “1 (the memory block is used)” for the corresponding memory block. b1 b2 b3 b4 b5 b6 b7
bit Memory Block b0 Memory Block #0 b1 Memory Block #1 b2 Memory Block #2 b3 Memory Block #3 b4 Memory Block #4
Set up Fusion Point Code (FPC) of Node which basic VNDM is mounted on. (1~253)
864 b3 Multiple IPs 0/1 = Out/In Service Note 1
FLF Fusion Service 0/1 = Invalid/Valid Note 2
ASYDN. Note 2: Available since the Series 7400 (Release 8) software.

ASYDL: Assignment of System Data into Local DM (LDM)
This command is used to assign and change system data for OAI activated via FCCS.
ASYDL command is comprised with System Data-1, INDEX 512-1535. This section only explains about ASYDL command for OAI System.
Refer to the following pages.

ASYDL
SYSTEM
BIT CORRESPONDING
SYSTEM
DATA (DATA) 00 – FF (Hex)
DATA TYPE (SYS)
DATA SYSTEM DATA CONTENTS
DATA
0/1 BIT
b0 Fusion Point Code (FPC) of self node in hexadecimal. FPC 1-253 (01 Hex-FD Hex)
b1 b2 b3 b4 b5 b6 b7
b0 Local Data Memory (LDM) usage. Assign data “1 (the memory block is used)” for the corresponding memory block. b1 b2 b3 b4 b5 b6 b7
bit Memory Block b0 Memory Block #0 b1 Memory Block #1 b2 Memory Block #2
515 IP Address (Hex) for PBX over External LAN Note: This data is valid when the PBX is connected to the external PC LAN. When 172.16.253.0 (default IP address) for the PBX is used, this data setting is not necessary. Example: IP Address : 133.206.8.1
INDEX Set Hex 515 85 516 CE 517 08 518 01
519 Subnet Mask (Hex) for PBX over External LAN Note: This data is valid when the PBX is connected to the external PC LAN. When 172.16.253.0 (default IP address) for the PBX is used, this data setting is not necessary. Example: Subnet Mask : 255.255.0.0
INDEX Set Hex 519 FF 520 FF 521 00 522 00

BIT CORRESPONDING
SYSTEM
SYSTEM
DATA INDEX (INDEX) 512-1535
DATA (DATA) 00 – FF (Hex)
DATA SYSTEM DATA CONTENTS
DATA
0/1 BIT
Default Gateway Address of External LAN Gateway Address (IP address of Router) of Network connecting PBX. Note: This data is valid when the PBX is connected to the external PC LAN. In the case of no Network Gateway, assignment data is 00 Hex. in Index 523 through 526.
INDEX Set Hex 523 85 524 CE 525 08 526 FE

1. General
This chapter explains the procedure for setting the office data required in the NEAX2400 IMX OAI System. As for the office data setting procedure of the NEAX2400 IMX System itself, refer to the System Data Design Manual.
The description of this Chapter consists of the following contents.
This section explains the procedure for setting the basic office data of the OAI system.
This section explains the procedure for setting the office data of the main services of the OAI system.

OFFICE DATA DESIGN Procedure for Setting Basic Office Data for OAI System
The procedure for setting the office data for OAI system is explained in the following.
2.1 Data for OAI System
ASYD-SYS1 INDEX31 - b0 ~ 3 : CM mounting capacity (Normally Assign “04”.) INDEX79 - b6 = 0 (OAI service is in service) INDEX207 - b0 (IP in system 0), b1 (IP in system 1) Assign “1” to the corresponding bit for the IP accommodation. INDEX241 - b2 = 1 (Call Processing Event Notification) INDEX241 - b3 = 1 (Details of SCF Error Notification) ASYDL-SYS1 INDEX513 : 01 Hex (LDM usage) INDEX515~518 : IP address (Hex) for PBX over External LAN INDEX519~522 : Subnet Mask (Hex) for PBX over External LAN INDEX523~526 : Default Gateway Address for External LAN (This data is required when the Host is connected via gateway) INDEX864 - b0 = 1 (Built-in IP is provided) INDEX864 b1 : Output the system message (4-R) when TCP-IP is normally
disconnected. 0/1 = Effective/Ineffective

OFFICE DATA DESIGN Procedure for Setting Basic Office Data for OAI System
2.2 Data for OAI Terminal
In the case of Dterm
Assign FKY34–47 to any positions of FKY 1–16. (Normal setting for others)
OAI key code 1 ~ 14 respectively corresponds to FKY34 ~ 47 of AKYD
In the case of Single-Line Telephone
SSCA: 69 (OAI Dial Number Continuous Transfer) NND : Necessary Number of Digits of OAI access code (Max. 3 digits)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
This section explains the outline, using conditions, and office data setting procedure of the main OAI service functions.
3.1 Switch Control Facility (SCF)
3.1.1 Functional Outline
The SCF is the facility that executes, from the Application Program (AP), such control operations as connections/disconnections between NEAX2400 IMX-accommodate terminal (Dterm) and another, between a Dterm and a C.O. Line Outgoing/Incoming Trunk, etc. The SCF has several functions (FN), and explanations will be given in the following about “Basic Connecting Function (FN = 1) – Make Call (Automatic Answer)” which is one of the several functions.


OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.1.2 Using Conditions
Destination Terminal Calling Terminal NEAX2400 Computer (AP)
(a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal.
(b) If the calling terminal and the destination terminal are idle, the NEAX2400 IMX sends out Return Result to the AP, and places the calling terminal into an outgoing connection status and the destination terminal into ringing status. These are the basic functions.
(c) When the destination terminal designated from the AP is a terminal in the NEAX2400 IMX and automatic answer is designated as the answer type, both the calling and destination terminals can be placed into speech status immediately from the status cited in (b) (After zip tone has been sent to both terminals, the terminals are placed into speech status.). Note that this service function is valid only when the destination terminal is in line selection wait status and also automatic answer is designated as the answer type. In other words, if the destination terminal is in a status other than line selection wait status, the call is to be answered manually. Further, this service function is valid only when the destination terminal is a station (Dterm: Voice) among the SCF Make Call designations. In other words, if the call destination is a trunk, this service function does not work.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
Destination Terminal Calling Terminal NEAX2400 Computer (AP)
(a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal.
(b) If the calling terminal and the destination terminal are in a status other than idle, the NEAX2400 IMX sends out Return Error to the AP.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.1.3 Data Programming
INDEX 79
Restrict a call origination from the prime line of the terminal of which answer type is designated as automatic answer
S: Outgoing call from a prime line (0/1)
Cancel restriction on a call origination from the prime line of the terminal of which answer type is designated as automatic answer
S: Outgoing call from a prime line (0/1)
INDEX 79
Assignment · Deletion

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.2 Call ID Notification (SMFN for ISDN)
3.2.1 Functional Outline
This Call ID Notification function is an enhancement of both the Call Termination Notification and the Answer Notification among Call Status Monitor Facility Notification functions of the OAI system, and provides the User’s Application Processor for External Computer (UAP) with the caller’s information when call termination is to be notified about an incoming call from the Integrated Services Digital Network (ISDN) concerned. Likewise, when the called terminal has answered an incoming call, this function also provides the UAP with the ISDN caller’s information.

3.2.2 Using Conditions

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
1≤n ≤54 D C
D C n –1
ISDN Caller’s Number Information
Subscriber number is maximum 33 digits, and the sub-address is maximum 20 digits, and they are separated by the separator “*” (OBH).
3.2.3 Data Programming
INDEX 79
INDEX 79
n · ASYD (System Data) · ASYD (System Data)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.3 MWL Control (SSF) STEP-1
3.3.1 Functional Outline
This function allows the Application Program (AP) to provide a single-line telephone equipped with Message Waiting Lamp (MWL) or a Dterm with the following Message Waiting (MW) services by the OAI Service Set Facility (SSF).


OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.3.2 Using Conditions
Terminal (Dterm) NEAX2400 IMX Computer (AP)
Terminal (Dterm) NEAX2400 IMX Computer (AP)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services


OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.3.3 Data Programming
INDEX 77
For providing centralized services at the Message Center within a No. 7 CCIS Network, assign the point codes for the remote offices belonging to the main office
CSN: Centralized Service Item No. (1 ~ 7) 1: Message Center CNT: Number of Remote Office Point Codes (1 ~ 32) RPC: Remote Office Point Code (1 ~ 16367)
Delete the point codes of the remote offices belonging to the main office
INDEX 77
Assignment · Deletion

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.4 TCP/IP Address (Assignment from MAT)
3.4.1 Functional Outline
In an OAI system to be connected with the host computer via the Ethernet, this function allows use of TCP/IP port with the self internet address (TCP/IP address) of the NEAX2400 IMX assigned from the MAT.
Also, whether system message “4-R” (IOC card for the host computer is faulty) is to be output or not when the connection with the host computer has been normally disconnected can be selected by switch setting on the Interface Processor (IP).
3.4.2 Using Conditions
3. The TCP/IP addresses (A, B, C, D) that cannot be used by this function are as follows. Classes A, B, and C can be used. Note that Host Number = 0 cannot be used. (Conditions [1] ~[3]. Classes D and E cannot be used. (Condition [4]) Class A: [1] 0 A 127 → A, 0, 0, 0 Class B: [2] 128 A 191 → A, B, 0, 0 (0 B 255) Class C: [3] 192 A 223 → A, B, C, 0 (0 B 255, 0 C 255) Class D, E: [4] 244 A → A, B, C, D (0 B 255, 0 C 255, 0 D 255)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.4.3 Data Programming
INDEX 515 ~ 518
INDEX 515 ~ 518
Stopping the system message of “4-R”
INDEX 864
b1 = 1 (The system message (4-R) is not output when TCP/IP connection is normally
disconnected.)
INDEX 864
TCP/IP Address Assignment · b1 = 0

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.5 Name Display
3.5.1 Functional Outline
This service is for displaying information (user’s name, station number, etc.) on the LCD of Dterm.
3.5.2 Using Conditions

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.5.3 Data Programming (Set up from User’s Application)
b0 = 1 (Intermediate Station Number Display is in service) b1 = 1 (Service Assortment Display is in service) b3: Dial Number Display 0/1: Out/In service b5 = 1 (Name Display Service is in service)
b5: Expanded Name Display (displaying 16-digit) 0/1: Out/In service b6 = 0 (OAI Service is in service)
b0: Intermediate Station Number Display 0/1: Out/In service b1: Service Assortment Display 0/1: Out/In service b3: Dial Number Display 0/1: Out/In service b5 = 0 (Name Display service is Out)
b5: Expanded Name Display (displaying 16-digit) 0/1: Out/In service b6 = 1 (OAI Service is Out)
b1 = 0 (Name Display is displaying 8-digit)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.6 Inter Node Name Display
3.6.1 Functional Outline
Name Display Service is available between the network. Name Display Service means for the facility of displaying letters (alphabet and etc.) on LCD of the Dterm. Catching call from other internal line
3.6.2 Using Conditions
Inter Node Name Display
Service Calling Party → Called party
Display of Calling party’s name Display of Called party’s name
16-digit → 8-digit 16-digit on Center Line (right side of 8-digit will be blank)
8-digit on Top Line (First 8-digit will be displayed)
8-digit → 16-digit 8-digit on Top Line (First 8-digit will be displayed)
16-digit on Center Line (right side of 8-digit will be blank)
8-digit → 16-digit → 8-digit 8-digit on Top Line 8-digit on Top Line
16-digit → 8-digit → 16-digit 16-digit on Center Line 8-digit on Center Line

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
CCIS
CCIS
B Office C Office
D Office (Name Display - System - CCIS is not serviced)
CCIS
In the case of (1): Name Display is serviced. In the case of (2): Name Display is not serviced. In the case of (3): Name Display is not serviced.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.6.3 Data Programming (Set up from User’s Application)
Those below are explanation of the Assignment according to Name Information which is set up from User’s Application.
SYS1
INDEX 78
b5 = 1 (Name Display Service is in service) b3: Dial Number Display 0/1: Out/In service
b6 = 0 (OAI Service is in service)
SYS1
INDEX 78
b6 = 1 (OAI Service is not in service)
b1 = 0 (Name Display 8-digit)
Assignment · Deletion

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.7 OAI Fusion
Main advantages of OAI Fusion fall down into the following. OAI Fusion systems can be divided into the following two types:
3.7.1 OAI Terminal Anywhere
3.7.1.1 Functional Outline
In this configuration (OAI Terminal Anywhere), the OAI terminal can be installed in any Fusion node whether the node has the IP or not (those OAI terminals in multiple nodes are controlled by one IP). In other words, the facilities in multiple nodes (any Fusion node whether the node has the IP or not) are controlled by one IP. (“Facility” which can be used through the Fusion Network varies in “the OAI application”.)

3.7.1.2 Using Conditions
(a) The Node that accommodates the IP is one node only in a Fusion network.
(b) Telephone Number (max. 5 digits) is used for the station number type to activated OAI system through Fusion network.
(c) Logical Route is used for the route type to activate OAI system through Fusion network.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
(d) The node that accommodates the IP must be initialized when all the other nodes are in on-line mode.
(e) The User’s Application (UAP) must be booted up after the confirmation of the establishment of the Fusion link.
(f) When you add a node/nodes to the network, you have to initialize the node that accommodates the IP.
3.7.1.3 Data Programming
(Data for OAI Fusion)
(a) ASYDL-SYS1 INDEX512 b0~7: Assign the self-Fusion Point Code (self-FPC) at each node.
(1~253) INDEX865 b0~7: FPC of the node providing IP Note: Assign 0 for the node that providing IP in the self-node only.
(a) ASYD/ASYDL • The data below are set to the node that accommodates IP ASYD - SYS1, INDEX207, b0:1=IP0 is used SYS1, INDEX207, b1:0/1=IP1 is not used/used ASYDL - SYS1, INDEX864, b0:1=Built-in IP is used
(c) The AKYD, AOKC command data are set to all nodes in Fusion network to be provided OAI system. (For these commands, assign data by the corresponding commands written in DM)
(1-253)

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.7.2 Multiple IPs
3.7.2.1 Functional Outline
In this configuration (Multiple IPs), IP can be accommodated to multiple nodes in a Fusion Network. Since Series 7400 (Release 8) software, establishing the CCIS line is not necessary to use OAI system through the network. (“Facility” which can be used through the Fusion Network varies in “the OAI application”.)

This feature is available with Series 7400 (Release 8) software.
3.7.2.2 Using Conditions
(a) Telephone Number (max. 5 digits) is used for the station number type to activated OAI system through Fusion network.
(b) Logical Route is used for the route type to activate OAI system through Fusion network.
(c) Only one IP to be used for “OAI Terminal Anywhere” can be contained in a Fusion Network (Multiple IPs).
(d) IP can be accommodated to multiple nodes in a Fusion Network. However, maximum number of Status Monitoring Requests to a terminal is decided by the system data (max. 8 ports available including UAP). Note that the normal operation is not guaranteed if Status Monitoring is requested to a terminal from more than the number of ports.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
(e) OAI terminals to be controlled from different IPs can not be accommodated in a node.

(f) When the IMG-U system is included in a Fusion Network (Multiple IPs), take the following conditions into consideration when programming data.

(a) IMG-U system where the OAI terminals are accommodated in multiple Local Nodes. In the IMG-U system, data programming for “OAI terminal Anywhere” must be programmed at the node that has IP (“IP1” in the figure below). In the network, another IP can not be used for “OAI terminal Anywhere” any more.
3.7.2.3 Data Programming
[Notice for Data Programming]
This section shows data programming divided into the types of OAI system (Figure 5-1).

The following are the network configuration of OAI system in a Fusion Network.
Type III : OAI Terminal Anywhere PBX3 - System providing the OAI terminals (Non-IP Node) PBX4 - System providing the OAI terminals (IP-Node)
Figure 5-1 Network Configuration of OAI systems

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
Table 5-1 OAI Software and System Data
Type and Node OAI
PBX1 PBX2 PBX3 PBX4 OAI Software
1 OAI Option Service software (basic) [Series 7400 (Release 8)] 2 ACD Option Service Software for “Agent Anywhere” System Data
3 CM Usage Note 1 (ASYD:SYS1, INDEX31, b0~b3) 0 4 4 4
4 OAI in service/out of service (ASYD:SYS1, INDEX79, b6) 1 0 0 0
5 No.0 CPU Mounted Status of IP00/1: Not mounted/Mounted (ASYD:SYS1, INDEX207, b0) 0 1 0 1
6 No.1 CPU Mounted Status of IP00/1: Not mounted/Mounted (ASYD:SYS1, INDEX207, b1) 0 Note 2 0 Note 2
7 OAI Call Processing Event Notification (ASYD:SYS1, INDEX241, b2) 0 1 1 1
8 SCF Return Error Detail Notification (ASYD:SYS1, INDEX241, b3) 0 1 1 1
9 Built-in IP:Not used/Used (ASYDL:SYS1, INDEX864, b0) 0 1 0 1
10 OAI Terminal Anywhere:Out of service/In service Note 3 (ASYDL:SYS1, INDEX864, b2) 0 0 1 1
11 MULTIPLE IPs:Out of service/In service Note 4 (ASYDL:SYS1, INDEX864, b3) 0 0 1 1
12 FPC Number of the node providing IP (ASYDL:SYS1, INDEX865) 0 0 Note 5 Note 5
13 Number of ports for SMFN (terminal) (ASYDL:SYS1, INDEX864, b4~5) 0 Note 6 Note 6 Note 6
14 FPC Number of Center Node providing VNDM (ASYDN:SYS1, INDEX533) Note 7 Note 7 Note 7 Note 7
: The software is installed to be linked with the standard service software using MSVIP command. Note 1: When CM is used for another function, this setting may be changed.
(Ex. Assign “6” Hex. when FLF Fusion service is used.) Note 2: When the CPU in system 1 is used, assign “1”. Note 3: Assign “1” at the all nodes using “OAI Terminal Anywhere” in the Fusion network that “MULTIPLE IPs” is provided. Note 4: When the all fusion nodes in the network are used for “MULTIPLE IPs”, this data may be assigned using ASYDN. Note 5: This data is required for UAP connection. Note 6: (This data is not necessary for the example above.) Assign this data so that the proper number of ports can be used when
more than three ports of Status Monitoring for terminal (SMFN). The identical data should be assigned at all nodes.
ASYDL SYS1 INDEX864 b4~5:
b5 b4 0 0 =2 ports 0 1 =8 ports Note 7: When the node using “OAI Terminal Anywhere” is included in the Fusion network that “Multiple IPs” is provided, assign
the FPC no. of IP node using “OAI Terminal Anywhere”.

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
PBX1 PBX2 PBX3 PBX4
Monitor Number Data (AMNO) N/L N
Conversion Number Data (ACNO) N/L N
Announcement/Dictation Data (AADT) N N
OAI Key Code Data (AOKC)
Key Data for Dterm (AKYD)
: Assign data by the corresponding commands written in DM. N : Assign data by the corresponding commands written in NDM. L : Assign data by the corresponding commands written in LDM when the call is not terminated from other nodes.
Type and Node · PBX Command Data

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services
3.7.3 Example of Use of Facility on Fusion Network
As a example of use of facilities through Fusion Network, the explanations will give in the following about Free Location Facility (FLF).
By using Free Location Facility (FLF) through Fusion Network, OAI Logical Number services can be used at any nodes in the Fusion network. This feature is available with the Series 7400 (Release 8) software.

OAI Logical Number 5000 is converted from Station Number 200 to Station Number 300
This service enables the Free Location Facility (FLF) beyond the nodes via the Fusion link. For example, if OAI Logical Number 5000 is converted from Station Number 200 at Node A to Station Number 300 at Node B. (Station Number 200 = OAI Logical Number 5000 → Station Number 300 = OAI Logical Number 5000) Information on OAI Logical Number Development is broadcast to all (Fusion network) nodes.
ASYD-SYS1 INDEX 31:06 (Mounting Capacity of Common Memory (CM) 6 Mbytes)
ASYDN-SYS1 INDEX 870, b0=1(FLF Fusion service is available)
ASYDL-SYS1 INDEX 864, b6=1 (FLF Error detailed Information is provided)

This page is for your notes.

This chapter explains maintenance, fault diagnosis out of system messages, fault repair procedure of the NEAX2400 IMX OAI System.
When a fault has been discovered in the course of maintenance works, the fault is to be diagnosed out of system messages and is to be repaired by the following fault repair procedure (Refer to Figure 6-1).
System messages indicating OAI fault
Figure 6-1 Flow of Maintenance Works

2.1 Routine Maintenance
By the routine maintenance on the NEAX2400 IMX OAI System, the following are performed.
A check is made to see if any system message pertaining to OAI faults is printed out. (Refer to Chapter 6, Section 3.1)
2.1.1 System Messages and Lamp Indications on TOPU
In the OAI system, an alarm lamp on TOPU corresponding to the faulty equipment lights up. The alarm lamps on TOPU corresponding to system messages are shown in Table 6-1.
Table 6-1 Relationship between System Messages and Alarm Lamps on TOPU
REMARKS No. NAME MJ MN SUP
4-R I/O Card Fault of IP ×
26-V LAN Interface Error Report ×
MAINTENANCE Maintenance

3.1 Outline
If any of the NEAX2400 IMX OAI functions becomes faulty, the corresponding system message shown in Table 6-2 is displayed. This section explains the meaning of each system message and message detail data.
Table 6-2 System Messages of OAI System
SYSTEM MESSAGE No. FAULT CONTENTS OF FAULT
4-R TCP/IP Link Failure A fault has occurred to the UAP or to the line connected with the external computer.
26-V LAN Interface Error Report A fault, related to the TCP/IP connection between the PBX and Host, occurred.
MAINTENANCE System Messages

3.2 Message Detail Data
This paragraph describes the detailed information on the faults indicated by system messages (message detail data).
3.2.1 Message Detail Data of System Message “4-R”
SYSTEM MESSAGE 4-R TCP/IP Link Failure NEC - ESD DEC 22 21:32
Fault port number: 0-5 Communication Protocol: 03 = ETHER + TCP/IP Error Code (ERRK): Refer to the table below (6-3 ERROR CODE) Fault logical channel number (LCID) : 01~10H (00 means the data is invalid)
Relation between LCID and PBX TCP port number
LCID TCP port number of the PBX
Table 6-3 Error Code
01 TCP Connection disconnected (Normal) Note 1
02 Reception of a text that cannot be analyzed Note 2
10 (0A) TCP Connection disconnected (On the way) Note 2
11 (0B) Transmission to PZ-PC19 (LANI) is disabled (Permanent) Note 2
12 (0C) Abnormal UAP is detected by Heart Beat function
13 (0D) Not used
14 (0E) TCP/IP Connection Error (B-level Infinite Loop, etc.) Note 2
15 (0F) Not used
message at some offices using SYS1, INDEX864, b1 in ASYDL (Other messages than ERRK = 01 is output when TCP connection disconnected is not output). Note 2: This data is output for Series 7300 Release 6 or earlier. If your system is Series 7300 Release 7 or later, the
message is output by 26-V” instead. (Refer to Section 3.2.2)

3.2.2 Message Detail Data of System Message “26-V”
SYSTEM MESSAGE 26-VLAN INTERFACE ERROR REPORT NEC - ESDJULY 25 19:30
TCP/IP PartApplication Part 1: xx 2: xx xx xx 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
~ IP address of the error-detected OAI/MIS terminal ~ Port No. Used socket No. Error Code (TCP/IP part)
Application Type 05 = OAI 07 = MIS (ACD) Faulty Logical Port No. Error Kind (ERRK) 01 = SEND Execution Error 02 = RECEIVE Execution Error 03 = TCP/IP Connection Error 04 = Connection Error (B-level Infinite Loop, etc.) 05 = TCP/IP Port Capacity Over
MAINTENANCE System Messages · -TCP/IP part- · -Application Part-

4.1 General
If a fault occurs to the NEAX2400 IMX OAI System, the corresponding system message is displayed. This section explains the procedures of fault diagnosis by system messages and of fault repairs.
Collection of Fault Information
Section 4. Item 4.2 Diagnosis from System Messages
Figure 6-2 Flow of Fault Repair
MAINTENANCE Fault Diagnosis

4.2 Diagnosis from System Messages
The flow of works from diagnosis of system message up to discovery of the cause of the fault is shown in Figure 6-3.
Diagnosis from System Message
Identification of Faulty Card, Faulty Equipment
Check the cause of the fault by diagnosing the printed out system messages.
If, during the diagnosis, an alarm such as circuit card initialization, etc., has been indicat- ed, reset (clear) the alarm indication by depressing ALM RST key on the frame-top alarm panel.
If, as a result of the diagnosis, the fault is a temporary one, cancel all alarm indications and release system messages stored in the memory by RALM command and keep watching the system operations thereafter.
Figure 6-3 Flow of Diagnosis out of System Messages
Fault Diagnosis

4.2.1 TCP/IP Link Failure
For details of System Massage “4-R” and “26-V”, see Section 3.2.1 and 3.2.2 in this Chapter.
According to each fault situation, perform the repairing procedure referring to Table 6-4 and Table 6-5.
When Message “4-R” is displayed:
Table 6-4 Repairing Procedure for TCP/IP Link Failure (Message “4-R”)
ERRK Detail information of ERRK Check Item
01 TCP/IP connection is down for the TCP connection disconnection from Host. Re-start the Host
Incorrect text format is received. [1] Check the software operation on the Host side
[2] Check the LAN cable connection
0A TCP/IP connection establishment is not completed for the TCP connection disconnection ordered from Host. Re-start the Host
TCP/IP connection establishment is not completed for the TCP connection disconnection ordered from Host.
[1] Check the TCP/IP transmission capacity on the UAP side is proper or not.
[2] Check the system operation on the UAP side.
0C According to Heart Beat function of Host, abnormal status of the Host system operation is detected. Check system operation of the Host
0E TCP port is released due to the detection of abnormal state in the TCP/IP port (such as B-level Infinite Loop, etc.). Re-check the operation status of Host.
When Message “26-V” is displayed:
Table 6-5 Repairing Procedure for TCP/IP Link Failure (Message “26-V”)
ERRK Detail information of ERRK Check Item
TCP/IP connection is down because the text is not transmit- ted continuously.
[1] Check the TCP/IP Transmission capacity on the UAP side is proper or not.
[2] Check the operation status on the UAP side is normal.
02 Incorrect text format is received. [1] Check the software operation on the Host side.
[2] Check the LAN cable connection status.
03 TCP/IP connection is released due to the TCP port discon- nection order from the Host. Re-start the Host computer.
04 TCP port is released due to the detection of abnormal state in the Host operation. Re-check the operation status of Host.
The number of allowed ports for application use via TCP/IP must be 16 or less. Adjust the total port number within this range.
05 TCP/IP connection cannot be established due to the connec- tion port capacity over.
MAINTENANCE Fault Diagnosis · 0D Not used · 0F~FF Not used

A
Host is still abnormal status?
Host is out of order. Repair the Host computer.
PZ-PC19 (LANI) card is out of order. For the replacement procedure, See “System Operation and Maintenance Manual”.
Fault Diagnosis · If yes, · If no,

This page is for your notes.