Table of Contents 27 sections Installation Guide · Model BF33STP/DXP BF39STP/DXP BF45DXP · 7206350500R09 · LISTING AND CODE APPROVALS · … ShowHide
Page 1 of the Dimplex Built-in Electric Firebox user manual — 7206350500R09
Page 1 · click to enlarge
Page 1
Dimplex Built-in Electric Firebox — Installation Guide diagram (page 1)
Fig. 1 · Installation Guide

Installation Guide

Model BF33STP/DXP BF39STP/DXP BF45DXP

7206350500R09

Page 2 of the Dimplex Built-in Electric Firebox user manual — Installation Guide
Page 2 · click to enlarge
Page 2
Page 2 of the Dimplex Built-in Electric Firebox user manual — Installation Guide
Page 3 of the Dimplex Built-in Electric Firebox user manual — STEP-BY-STEP INSTALLATION
Page 3 · click to enlarge
Page 3

LISTING AND CODE APPROVALS

The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters.

Dimplex Built-in Electric Firebox — LISTING AND CODE APPROVALS diagram (page 3)
Fig. 2
Model NumberDescriptionVoltageRated Power (Watts)Remote ControlWall ThermostatRefractory Brick LookCurrent Draw (Amps) No Heat 120V120V208V240V BF45DXP45" Deluxe120/120/ 208/240245/1440/ 2100/2700OptionalOptionalIncluded2.012.010.1011.25 BF39DXP39" DeluxeIncluded2.012.010.1011.25 BF39STP39" StandardN/A2.012.010.1011.25 BF33DXP33" DeluxeIncluded2.012.010.1011.25 BF33STP33" StandardN/A2.012.010.1011.25

STEP-BY-STEP INSTALLATION

! NOTE: Please read all instructions before installing. 1. Rough in framing opening following the recommended dimensions located in Section A: Framing Dimensions. 2. Allow 8" (20.3 cm) of service cable for connecting power supply wire to junction box on fireplace when installing before finishing wall. Allow up to 4' (121.9 cm) of service cable for connecting power supply wire to junction box on fireplace when installing after finishing wall. Remove the outer jacket and strip the individual conductors ½" (1.3 cm) from the end. 3. Loosen the screw securing the junction box cover and remove the cover. 4. Remove knockouts, if necessary, or use the provided cable clamp. 5. Place unit in position in the framed opening, level with shims if necessary and attach unit to frame using mounting flanges provided (Figure 2). 6. Unit is factory wired for 208/240V power supply. If 120V operation is required, slide the switch and reconfigure the wiring (Section C). Wires L1, L2, N & G are attached to the rear of the junction box cable clamp for easy access. ! NOTE: If wiring unit to operate with NO heat a dedicated circuit may not be required. 7. Wire a dedicated, properly fused circuit with a 15amp rating for the appropriate voltage (120V, 208/240V). See Section C for factory setting wiring. 8. Make wall switch and or wall mounted thermostat connections as outlined in Section D. 9. Place all connectors inside the unit and secure the junction box cover to unit. Ensure that the cable clamp grips only the jacket of service cable, thermostat and if applicable wall switch lines. WARNING: Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner.

(See diagram in Section A)

Page 4 of the Dimplex Built-in Electric Firebox user manual — LISTING AND CODE APPROVALS
Page 4 · click to enlarge
Page 4
Dimplex Built-in Electric Firebox — LISTING AND CODE APPROVALS diagram (page 4)
Fig. 3
ModelA -B C D E 0 / +0.1 -0 / +0.1F G HIJKL BF45DXP16.0" (40.5cm) (45" 32.9" 30.1" 15.3" 114.3cm) (83.6cm) (76.5cm) (38.9cm)42.0" 44.7" 22.8 (106.7cm) (113.5cm) (57.9c" 32.7" m) (83.1cm)60.0" (152.4cm)42.0" (106.7cm)42.0" (106.7cm) BF39STP/DXP16.0" (40.5cm) (39" 32.9" 30.1" 15.3" 99.1cm) (83.6cm) (76.5cm) (38.9cm)36.0" 38.7" 22.8 (91.4cm) (98.3cm) (57.9c" 32.7" m) (83.1cm)54.0" (137.2cm)38.0" (96.5cm)38.0" (96.5cm) BF33STP/DXP15.0" (38.1cm) (33.1" 28.7" 25.7" 14.3" 84.1cm) (72.9cm) (65.3cm) (36.3cm)29.6" 32.8" 18.8 (75.2cm) (83.3cm) (47.8c" 28.5" m) (72.4cm)48.0" (121.9cm)34.0" (86.4cm)34.0" (86.4cm)
Dimplex Built-in Electric Firebox — LISTING AND CODE APPROVALS diagram (page 4)
Fig. 4

This fireplace is a zero clearance design, with the exception of the top of the unit, where any insulation and vapor barrier should be placed a minimum of 2" (5.1 cm) from the unit. No combustibles can be placed on the top surface of the fireplace.

Dimplex Built-in Electric Firebox — LISTING AND CODE APPROVALS diagram (page 4)
Fig. 5

There are two mounting flanges located on each side of the fireplace insert. From the inside of the unit, bend tabs outward and mount to the inside of the framing using suitable hardware.

Page 5 of the Dimplex Built-in Electric Firebox user manual — RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS
Page 5 · click to enlarge
Page 5

SECTION B: GENERAL ELECTRICAL INFORMATION

RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS

For 120V installations use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply on fireplace inserts. Use the appropriate wire to meet local and national electrical codes for rated power consumption. For 208V / 240V installations use three conductor, non-metallic sheath cable with ground wire (4 wires total) for the incom- ing power supply on fireplace inserts. Use the appropriate wire to meet local and national electrical codes for rated power consumption. Two conductor, non-metallic sheath cable with ground wire (3 wires total) is recommended for installation of a wall mounted thermostat and/or wall switch for use on fireplace inserts. Use appropriate wire to meet local and national electrical codes for rated power consumption. All wire gauges should match the recommended wire sizes shown below.

Dimplex Built-in Electric Firebox — RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS diagram (page 5)
Fig. 6
VoltageWire GaugeFuse Rating 20 Volts14 Gauge15 Amp 08 Volts14 Gauge15 Amp 40 Volts14 Gauge15 Amp

! IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. ! NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner.

CAUTION: When changing the voltage selector switch from 240V to 120V ensure that the power supply is turned off. ! NOTE: Carefully insert a flat headed screwdriver inside the exhaust panel to change the switch from 240V (230 position) to 120V (115 position). When wiring the unit for 208V / 240V the voltage selector switch should be in the 230V position. When wiring the unit for 120V the voltage selector switch should be in the 115V position.

Page 6 of the Dimplex Built-in Electric Firebox user manual — 120V INSTALLATION
Page 6 · click to enlarge
Page 6

SECTION C: DIRECT POWER WIRING

240V INSTALLATION

WHITE WIRE - N

WHITE WIRE - N

RED WIRE – L2

RED WIRE – L2

BLACK WIRE – L1

BLACK WIRE – L1

GREEN WIRE - G

GROUND WIRE - G

! IMPORTANT: The unit is factory configured for 208/240V operation. ! NOTE: Use 3 conductor wires with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit. ! NOTE: All wiring must be completed prior to installing the unit. ! NOTE: Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting

the unit to the power supply. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 240V position. (230 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover. 3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G. 5. Connect L1 (black) from the unit to the L1 (black) from the power supply. 6. Connect L2 (red) from the unit to the L2 (red) from the power supply. 7. Connect N (white) from the unit to the to the Neutral (white) from the power supply. 8. Connect the ground wire (green) from the unit to the ground from the power supply. 9. Ensure that all connections are tight. 10. Insert all the wiring back into the unit and secure with a cable clamp.

120V INSTALLATION

WHITE WIRE - N

WHITE WIRE - N

RED WIRE – L2

BLACK WIRE – L1

BLACK WIRE – L1

GROUND WIRE - G GREEN WIRE - G

! IMPORTANT: The unit is factory configured for 208/240V operation. ! NOTE: Use 2 conductor wires with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. ! NOTE: All wiring must be completed prior to installing the unit. ! NOTE: Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting

the unit to the power supply. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from 240V to 120V configuration. (230 and 115 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover.

Page 7 of the Dimplex Built-in Electric Firebox user manual — 120V INSTALLATION - NO HEAT INSTALLATION
Page 7 · click to enlarge
Page 7

3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G. 5. Connect L1 (black) wire from the unit to the L1 (black) from the power supply. 6. Connect L2 (red) and N (white) from the unit to the Neutral (white) from the power supply. 7. Connect the ground wire (green) from the unit to the ground from the power supply. 8. When the unit has been configured for the appropriate power supply voltage, ensure that all connections are tight. 9. Insert all the wiring back into the unit and secure with a cable clamp.

120V INSTALLATION - NO HEAT INSTALLATION

WHITE WIRE - N

WHITE WIRE - N

RED WIRE – L2

BLACK WIRE – L1

BLACK WIRE – L1

GREEN WIRE - G

GROUND WIRE - G

RED - 2 WIRE NUTS

! IMPORTANT: The unit is factory configured for 208/240V operation. ! NOTE: Use 2 conductor wires with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. ! NOTE: All wiring must be completed prior to installing the unit. ! NOTE: Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting

the unit to the power supply. ! NOTE: the fan will operate without heat in this application. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from 240V to 120V configuration. (230 and 115 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover. 3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G. 5. Connect L1 (black) wire from the unit to the L1 (black) from the power supply. 6. Connect L2 (red) and N (white) from the unit to the Neutral (white) from the power supply. 7. Connect the ground wire (green) from the unit to the ground from the power supply. 8. Locate and separate, by installing a wire nut on the 1 (red) and 2 (red). 9. When the unit has been configured for the appropriate power supply voltage, ensure that all connections are tight. 10. Insert all the wiring back into the unit and secure with a cable clamp.

Page 8 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 8 · click to enlarge
Page 8
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 8)
Fig. 7

! NOTE: This option should not be used with the remote control kit. ! NOTE: Before installing the unit have the following wires installed:

1. A 3 conductor wire with ground (4 wires total) from the power supply panel to the main switch wall box. 2. A 3 conductor wire with ground (4 wires total) from the main switch wall box to the junction box on the unit. ! NOTE: Use a double pole, single throw (On/Off) wall switch that is rated for a minimum of 15 amps. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 240V position. (230 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover. 3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G. (black, red, white and green) 5. Connect the L1 (black) wire from the unit to the L1 (black) wire from the main power wall switch by using a wire connector (not supplied). 6. Connect other end of L1 (black) wire from the main power wall switch to the L1 terminal of the main power wall switch. 7. Connect the L2 (red) wire from the unit to the L2 (red) wire from the main power wall switch by using a wire connector (not supplied). 8. Connect the other end of the L2 (red) wire from the main power wall switch to the L2 terminal of the main power wall switch. 9. Connect the N (white) wire from the unit to the N (white) wire from the main power wall switch by using a wire connector (not supplied). 10. Connect the G (green) wire from the unit to the G (green) wire from the main power wall switch by using a wire connector (not supplied). 11. Connect the L1 wire from the power supply to the L1 terminal of the main power wall switch. 12. Connect the L2 (black) wire from the power supply to the L2 terminal of the main power wall switch. 13. Connect the N (white) wire from the power supply to the remaining N (white) wire from the unit by using a wire connector. 14. Secure the 2 remaining G (green) wires with a ground screw in the main switch wall box. 15. Ensure that all connections are tight. 16. Insert all the wiring of the main power wall switch into the main switch wall box. 17. Insert all the wiring back into the unit and secure with a cable clamp.

POWER SUPPLY

G FROM

L1 FROM

POWER SUPPLY

L2 FROM

POWER SUPPLY

NEUTRAL FROM

UNIT AND SUPPLY

NEUTRAL FROM

UNIT AND SUPPLY

N

3 CONDUCTOR WIRE FROM POWER SUPPLY

3 CONDUCTOR WIRE FROM MAIN SWITCH

N

Page 9 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 9 · click to enlarge
Page 9
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 9)
Fig. 8

! NOTE: This option should not be used with the remote control kit. ! NOTE: Before installing the unit have the following wires installed:

1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 2. A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit. ! NOTE: Use a single pole, single throw (On/Off) wall switch that is rated for a minimum of 15 amps. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 120V position. (115 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover. 3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G (black, red, white and green). 5. Connect L1 (black) from the unit to the L1 (black) from the main power wall switch using a wire connector (not supplied). 6. Connect the other end of L1 (black) to the L1 terminal of the main power wall switch. 7. Connect L2 (red) from the unit and N (white) from the unit to the Neutral wire (white) of the main power wall switch by us- ing a wire connector (not supplied). 8. Connect the other end of the N (white) to the Neutral wire (white) from the power supply panel by using a wire connector (not supplied). 9. Connect Ground (green) from the unit to the Ground (green) wire of the main power wall switch by using a wire connector (not supplied). 10. Connect L1 (black) wire from the power supply to the L1 terminal of the main power wall switch. 11. Secure the 2 remaining Ground wires (green) with a ground screw in the main switch wall box. 12. Ensure that all connections are tight. 13. Insert all the wiring of the main power wall switch into the main switch wall box. 14. Insert all the wiring back into the unit and secure with a cable clamp.

Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 9)
Fig. 9
Page 10 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 10 · click to enlarge
Page 10
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 10)
Fig. 10

! NOTE: This option should not be used with the remote control kit. ! NOTE: Before installing the unit have the following wires installed:

1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 2. A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit. ! NOTE: Use a single pole, single throw (On/Off) wall switch that is rated for a minimum of 15 amps. 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 120V position. (115 is printed on switch) 2. Loosen the screw securing the junction box cover and remove the cover. 3. Remove the knockouts (if necessary) or use the provided cable clamp. 4. Pull out the four wires marked L1, L2, N, and G (black, red, white and green). 5. Connect L1 (black) from the unit to the L1 wire (black) from the main power wall switch using a wire connector (not supplied). 6. Connect the other end of the L1 wire (black) to the L1 terminal of the main power wall switch. 7. Connect L2 (red) from the unit and the N (white) from the unit to the Neutral wire (white) of the main power wall switch by using a wire connector (not supplied). 8. Connect the other end of the Neutral wire (white) to the Neutral wire (white) from the power supply panel by using a wire connector (not supplied). 9. Connect the Ground wire (green) from the unit to the Ground wire (green) of the main power wall switch by using a wire connector (not supplied). 10. Connect L1 (black) from the power supply to the L1 terminal of the main power wall switch. 11. Locate and separate by wire nut the 1 (red) and 2 (red). 12. Secure the 2 remaining Ground wires (green) with a ground screw in the main switch wall box. 13. Ensure that all connections are tight. 14. Insert all the wiring of the main power wall switch into the main switch wall box. 15. Insert all the wiring back into the unit and se- cure with a cable clamp.

Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 10)
Fig. 11
Page 11 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 11 · click to enlarge
Page 11
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 11)
Fig. 12
! NOTEBefore installing the unit complete the following:

1. Install main power connection with appropriate wiring - directly to the main power or through a wall switch. 2. Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit. ! NOTE: Use a heater wall switch (On/Off) that is rated for a minimum of 15 amps. 1. Loosen the screw securing the junction box cover and remove the cover. 2. Remove the knockouts (if necessary) or use the provided cable clamp. 3. Pull out the three wires marked 1, 2, and G (red, red, and green). 4. Remove the wire connector and separate the wires marked 1 and 2. 5. Connect the 1 wire (red) from the unit to the L1 wire (black) from the heater wall switch by using a wire connector (not supplied). 6. Connect the other end of L1 wire (black) from the heater wall switch to the L1 terminal of the heater wall switch. 7. Connect the 2 wire (red) from the unit to the Neutral wire (white) from the heater wall switch using a wire connector (not supplied). 8. Connect the other end of the Neutral wire (white) from the heater wall switch to the L2 terminal of the heater wall switch. 9. Connect the Ground wire (green) from the unit to the Ground wire (green) from the heater wall switch using a wire connector (not supplied). 10. Secure the remaining Ground wire (green) with a ground screw in the heater switch wall box. 11. Ensure that all connections are tight. 12. Insert all the wiring of the heater wall switch into the heater switch wall box. 13. Insert all the wiring back into the unit and secure with a cable clamp.

Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 11)
Fig. 13

heater switch connection, see previous sections for main power connection instructions.

Page 12 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 12 · click to enlarge
Page 12
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 12)
Fig. 14
! NOTEBefore installing the unit complete the following:

1. Install main power connection with appropriate wiring - directly to the main power or through a wall switch. 2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box on the unit. ! NOTE: Wiring of the thermostat must be completed prior to installing the unit. ! NOTE: The following installation instructions are for a single pole thermostat. 1. Loosen the screw securing the junction box and remove the cover. 2. Remove the knockouts (if necessary) or use the provided cable clamp. 3. Pull out the three wires marked 1, 2, and G (red, red, and green). 4. Remove the wire connector and separate the wires marked 1 & 2. 5. Connect the 1 wire (red) from the unit to the Neutral (white) wire from the wall thermostat box by using a wire connector (not supplied). 6. Connect the other end of the Neutral (white) wire from the thermostat wall box to the red wire from the wall thermostat. 7. Connect the 2 wire (red) from the unit to the black wire from the thermostat wall box by using a wire connector (not supplied). 8. Connect the other end of the black wire from the thermostat wall box to the black wire from the wall thermostat. 9. Connect the Ground wire (green) from the unit to the Ground (green) wire from the thermostat wall box by using a wire connector (not supplied). 10. Connect the other end of the Ground wire (green) to the thermostat wall box ground screw. 11. Ensure that all connections are tight. 12. Insert all the wiring of the wall mounted thermostat into the wall box. 13. Insert all the wiring back into the unit and secure with a cable clamp.

Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 12)
Fig. 15

thermostat connection, see previous sections for main power connection instruc- tions.

Page 13 of the Dimplex Built-in Electric Firebox user manual — POWER SUPPLY
Page 13 · click to enlarge
Page 13
Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 13)
Fig. 16

DO NOT USE WITH NO HEAT INSTALLATIONS! NOTE: The fireplace can be wired to have a wall switch operate the flame independent of the heater. ! NOTE: Before installing the unit complete the following:

1. Install main power connection with appropriate wiring - directly to the main power or through a wall switch. 2. Install a 2 conductor wire with ground (3 wires total) from the flame override switch wall box to the junction box on the unit. ! NOTE: Use a wall switch (On/Off) that is rated for a minimum of 15 amps. 1. Loosen the screw securing the junction box cover and remove the cover. 2. Remove the knockouts (if necessary) or use the provided cable clamp. 3. Pull out the three wires marked 3, 4, and G (blue, blue, and green). 4. Remove the wire connector and separate the wires marked 3 and 4. 5. Connect 3 wire (blue) from the unit to the L1 wire (black) from the flame override wall switch by using a wire connector (not supplied). 6. Connect the other end of the L1 wire (black) from the flame override wall switch to the L1 terminal of the flame override wall switch. 7. Connect 4 wire (blue) from the unit to the Neutral wire (white) from the flame override wall switch using a wire connector (not supplied). 8. Connect the other end of the Neutral wire (white) from the flame override wall switch to the L2 terminal of the flame override wall switch. 9. Connect the Ground wire (green) from the unit to the Ground wire (green) from the flame override wall switch using a wire connector (not supplied). 10. Secure the remaining Ground wire (green) with a ground screw in the flame override switch wall box. 11. Ensure that all connections are tight. 12. Insert all the wiring of the heater wall switch into the heater switch wall box. 13. Insert all the wiring back into the unit and secure with a cable clamp.

Dimplex Built-in Electric Firebox — POWER SUPPLY diagram (page 13)
Fig. 17

flame switch connection, see previous sections for main power connection instructions.

Page 14 of the Dimplex Built-in Electric Firebox user manual — WALL REMOTE - WRCPF-KIT
Page 14 · click to enlarge
Page 14

WALL REMOTE - WRCPF-KIT

1. Room Temperature 2. Set Temperature 3. Flame Effect 4. Fan 5. Heat Off Indicator 6. Function Lock Indicator 7. RF Code Function Indicator 8. Set Temperature Down 9. Set Temperature Up 10. Flame Off 11. Flame On 12. Fan Off 13. Fan On 14. Low Battery Indicator
Dimplex Built-in Electric Firebox — WALL REMOTE - WRCPF-KIT diagram (page 14)
Fig. 18
  • Can be used for 120V or 240V installations
  • Battery or 24V powered
  • 50' (15m) control range
  • Built in Thermostat
  • Flame On/Off Control
  • Heat On/Off Control

In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.

© 2018 Glen Dimplex Americas

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex Built-in Electric Firebox

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex Built-in Electric Firebox

Be the first to ask — other owners or our team will answer.

Original document

Dimplex Built-in Electric Firebox manual PDF

42 pages·5.8 MB·Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…