Wireless Data Logging
Digital Multimeter User Manual
Thank you for purchasing this Wireless Data Logging Digital Multimeter. The wireless communication function of this multimeter allows you to transmit data wirelessly from the multimeter to your PC. This allows accurate recording at a much faster and detailed rate than manually writing down numbers. The true RMS function ensures accurate readings, regardless of load type or current wave shape. Packed with plenty of features, this multimeter will be your constant companion on-site, given its tough double moulded body and IP67 rating.
Please familiarise yourself with the functions of the multimeter before use. We recommend retaining this manual for ease of reference.



Hold & Flashlight Button
Positive mA, μA Input Jack
Positive mA, μA Input Jack
The tilt stand & battery compartment are at the rear of the multimeter.



AC/DC VOLTAGE MEASUREMENT On some low AC and DC voltage ranges - when test leads are not connected to a device - the display on the screen may show a random, changing reading. This is normal and caused by high-input sensitivity of the multimeter. When connected to a circuit, the multimeter will display a stabilised, accurate measurement.

DC CURRENT MEASUREMENT Do not measure 20A currents for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or test leads.
AC/DC VOLTAGE MEASUREMENT On some low AC and DC voltage ranges - when test leads are not connected to a device - the display on the screen may show a random, changing reading. This is normal and caused by high-input sensitivity of the multimeter. When connected to a circuit, the multimeter will display a stabilised, accurate measurement.

DC CURRENT MEASUREMENT Do not measure 20A currents for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or test leads.
AC CURRENT MEASUREMENT Do not measure 20A currents for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or test leads.

RESISTANCE MEASUREMENT To avoid electric shock, disconnect power to the test area and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.
1) Set the function switch to the Ω CAP position. 2) Insert the black test lead banana plug into the negative COM jack. 3) Insert the red test lead banana plug into the positive Ω jack. 4) Press the MODE button until “Ω” displays on the screen. 5) Touch the test probe tips across the circuit or part being tested. It is best to disconnect one side of the part being tested so the rest of the circuit will not interfere with the resistance reading. 6) Read the resistance displayed on the screen.
CONTINUITY CHECK To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.
DIODE TEST The value that displays on screen during the diode check is the forward voltage.

A) If one reading shows a value and the other reading shows OL, the
diode is good. B) If both readings show OL, the device is open. C) If both readings are very small or zero, the device is shorted.
CAPACITANCE MEASUREMENTS To avoid electric shock, disconnect power to the area being tested and discharge all capacitors before taking any capacitance measurements.
1) Set the function switch to the Ω CAP position. 2) Insert the black test lead banana plug into the negative COM jack. 3) Insert the red test lead banana plug into the positive VΩCAP jack. 4) Press the MODE button until “nF” displays on the screen. 5) Touch the test leads to the capacitor being tested. 6) The test may take up to three minutes or more for large capacitors to charge. Wait until the readings settle before ending the test. 7) Read the capacitance value displayed on the screen.
TEMPERATURE MEASUREMENTS The temperature probe is fitted with a type K mini connector. A mini connector to banana connector adaptor is supplied for connection to the input banana jacks.
FREQUENCY MEASUREMENT 1) Set the function switch to the HZ% position. 2) Insert the black test lead banana plug into the negative COM jack. 3) Insert the red test lead banana plug into the negative VΩCAP jack. 4) Touch the test probes to the circuit being tested. 5) Read the frequency displayed on the screen.

MEASUREMENT SPECIFICATIONS The following guide is based on an environmental temperature of 18- 28°C and humidity
Input impedance: 10MΩ; Max. input voltage: 1000VAC RMS; Frequency range: 50~400Hz; all AC voltage ranges are specified from 5% of range to 100% of range.

RANGE RESOLUTION ACCURACY
400µA 0.1µA
±(1.2% reading + 3 digits) 4000µA 1µA
10A 10mA ±(2.5% reading + 3 digits)
Overload protection: fuse FF500mA/1000V and fuse F10A/1000V. Maximum inputs: 400µA DC (µA range), 400mA DC (mA range), 10A DC (10A range).
RANGE RESOLUTION ACCURACY
400µA 0.1µA
±(1.5% reading + 5 digits) 4000µA 0.001mA
40mA 0.01mA
400mA 0.1mA
10A 10mA ±(3.0% reading + 5 digits)
40mA 10µA · 400mA 100µA

RANGE RESOLUTION ACCURACY
400Ω 0.1Ω ±(0.8% reading + 5 digits)
±(0.8% reading + 2 digits) 40kΩ 10Ω
4MΩ 1kΩ ±(2.5% reading + 8 digits) 40MΩ 10kΩ
RANGE RESOLUTION ACCURACY
40nF 10pF ±(5.0% reading + 7 digits)
400nF 0.1nF
±(3.0% reading + 5 digits) 4µF 1nF
100µF 0.1µF ±(5.0% reading + 7 digits)
RANGE RESOLUTION ACCURACY
0.1~99.9% 0.1% ±(1.2% reading + 2 digits)
Pulse width: >100us,
4kΩ 1Ω · 400kΩ 100Ω · 40µF 10nF

RANGE RESOLUTION ACCURACY
4Hz 0.001Hz
40Hz 0.01Hz
400Hz 0.1Hz
±(1.0% reading + 3 digits)
5MHz 1kHz ±(1.2% reading + 4 digits)
Overload protection: 1000VDC or 1000VAC RMS. Sensitivity >0.5V while ≤1MHz, >3V while >1MHz.
RANGE RESOLUTION ACCURACY
-20°C to 760°C 1°C ±(3% reading + 5 digits)
Overload protection: 1000VDC or 1000VAC RMS.
RANGE FUNCTION
Display approximate forward voltage of diode
Built-in buzzer will sound if resistance is less than 30Ω
4kHz 1Hz · 40kHz 10Hz · 400kHz 100Hz

TEST CURRENT RESOLUTION ACCURACY
1mA typical/open max 3V 1mV ±(10% reading + 5 digits)
Open circuit voltage max 3V; overload protection 1000VDC or 1000VAC RMS.
THRESHOLD TEST CURRENT
Less than 150Ω Maximum 1.5mA
BATTERY INSTALLATION To avoid the false readings, replace the battery as soon as the low battery power indicator appears.
REPLACING FUSES 1) Turn power off and disconnect the test leads from the meter. 2) Remove the battery cover. 3) Gently remove the old fuse and install the new fuse into the holder. 4) Always use a fuse of the proper size and value (0.5A/1000V fast blow for the 400mA range, 10A/1000V fast blow for the 10A range). 5) Replace and secure the cover.

SPECIFICATIONS Enclosure: Double-molded AC Response: TRMS Display: 4,000 count LCD display Over Range Indication: “OL” is displayed Auto Power: 30 min (approx) Polarity: Automatic (no indication for positive); minus (-) sign for negative Low Battery Indication: is displayed if battery voltage drops below operating voltage Battery: 1 x 9V Operating Temperature: -10°C to 50°C Storage Temperature: -30°C to 60°C Operating Humidity:
BOX CONTENTS 1 x Multimeter 1 x Test Leads 1 x Carry Case 1 x 9V Battery 1 x User Manual