Quick Guide

We warrant that the product will be free from defects in materials and workmanship for a period of 3 years (1 year for accessories) from the date of purchase of the product by the original purchaser from our company. This warranty only applies to the original purchaser and is not transferable to a third party.
If the product proves defective during the warranty period, we will either repair the defective product without charge for parts and labour, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by our company for warranty work may be new or reconditioned like new. All replaced parts, modules and products become the property of our company.
In order to obtain service under this warranty, the customer must notify our company of the defect before the expiration of the warranty period. Customer shall be responsible for packaging and shipping the defective product to the designated service centre, a copy of the customers proof of purchase is also required.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. We shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than our company representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of not our supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
Please contact the nearest Sales and Service Offices for services. Excepting the after-sales services provided in this summary or the applicable warranty statements, we will not offer any guarantee for maintenance definitely declared or hinted, including but not limited to the implied guarantee for marketability and special-purpose acceptability. We should not take any responsibilities for any indirect, special or consequent damages.


1.Safety Information
Safety Terms
Terms in this Manual. The following terms may appear in this manual:
injury or loss of life.
damage to this product or other property.
Terms on the Product. The following terms may appear on this product:
Symbols on the Product. The following symbol may appear on the product:
manual for specific Warning or
Both direct and alternating current
Conforms to European Union
IEC Measurement Category I. The maximum measurable
voltage is 1000 Vpk in the HI -LO terminal.
IEC Measurement Category II. Inputs may be connected to AC
mains power (up to 600 VAC) under Category II overvoltage
conditions.
This product complies with the WEEE Directive (2012/19/EC)
marking equipment. The affixed product label indicates that
you must not discard this electrical/electronic product in
domestic household waste.

1.Safety Information
Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage. In order to avoid any contingent danger, this product is only used within the range specified.
Check AC power input setting according to the standards in your own country.
Use Proper Power Cord. Use only the power cord supplied with the product and certified to use in your country.
Product Grounded. This instrument is grounded through the power cord grounding conductor. To avoid electric shock, the grounding conductor must be grounded. The product must be grounded properly before any connection with its input or output terminal.
Limit operation to the specified measurement category, voltage, or amperage ratings.
Check all Terminal Ratings. To avoid instrument damage and the risk of electric shock, check all the Measurement Limits and markers of this product. Refer to the user's manual for the Measurement Limits before connecting to the instrument. Do not exceed any of the Measurement Limits defined in the following section.
Do not operate without covers. Do not operate the instrument with covers or panels removed.
Use Proper Fuse. Use only the specified type and rating fuse for this instrument.
Avoid exposed circuit. Do not touch exposed junctions and components when the instrument is powered.
Do not operate if in any doubt. If you suspect damage occurs to the instrument, have it inspected by qualified service personnel before further operations.
Use your instrument in a well-ventilated area. Inadequate ventilation may cause increasing of temperature or damages to the device. Please keep well ventilated and inspect the intake regularly.
Do not operate in wet conditions. In order to avoid short circuiting to the interior of the device or electric shock, please do not operate in a humid environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Only the qualified technicians can implement the maintenance.

1.Safety Information
The protection circuitry of the multimeter can prevent damage to the instrument and protect against the danger of electric shock, when the Measurement Limits are not exceeded. To ensure safe operation of the instrument, do not exceed the Measurement Limits shown on the front panel, it is defined as follows:

The user-replaceable 10 A current-protection fuse is on the front panel. To maintain protection, replace fuse only with fuse of the specified type and rating. About the specified type and rating of the fuse, please refer to "7 Current Terminal Fuse" in "Front Panel Overview" on page 7.
The HI and LO input terminals are used for voltage, resistance, continuity, frequency (period), capacitance, diode, and temperature test measurements. Two Measurement Limits are defined for these terminals:
HI Input to LO Input Measurement Limit
The Measurement Limit from HI Input to LO Input is 1000 VDC or 750 VAC, which is also the maximum voltage measurement. This limit can also be expressed as 1000 Vpk maximum.
LO Input to Ground Measurement Limit
The LO input terminal can safely "float" a maximum of 500 Vpk relative to ground, where ground is defined as the Protective Earth Conductor in the AC mains power cord connected to the instrument.
As implied by the above limits, the Measurement Limit for the HI input terminal is a maximum of 1500 Vpk relative to ground when LO Input is at its maximum of 500 Vpk relative to ground.
The Measurement Limit from the current input terminal (I) to the LO Input terminal is 10 A (DC or AC). Note that the current input terminals will always be at approximately the

1.Safety Information
same voltage as the LO Input terminal, unless a current protection fuse is open.
The HI and LO sense terminals are used for four-wire resistance measurements. The Measurement Limit from HI Sense to LO Input is 200 Vpk. The Measurement Limit from HI Sense to LO Sense is 200 Vpk. The Measurement Limit from LO Sense to LO Input is 2 Vpk.
The safety rating of the multimeter:
1000 V, CAT I IEC Measurement Category I. The maximum measurable voltage is 1000 Vpk in the HI -LO terminal.
600 V, CAT II IEC Measurement Category II. Inputs may be connected to AC mains power (up to 600 VAC) under Category II overvoltage conditions.
Measurement CAT I applies to measurements performed on circuits not directly connected to the AC mains. Examples are measurements on circuits not derived from the AC mains and specially protected (internal) mains- derived circuits. Measurement CAT II applies to protect against transients from energy-consuming equipment supplied from the fixed installation, such as TVs, PCs, portable tools, and other household circuits. Measurement CAT III applies to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. Measurement CAT IV applies to measurements performed at the source of the low- voltage installation. Examples are electricity meters and measurements on primary over current protection devices and ripple control units.

After you get a new multimeter, it is recommended that you should make a check on the instrument according to the following steps:
If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests.
The supplied accessories have been already described in the Appendix A: Enclosure of this Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with our distributor responsible for this service or our local offices.
If it is found that there is damage to the appearance of the instrument, or the instrument cannot work normally, or fails in the performance test, please get in touch with our distributor responsible for this business or our local offices. If there is damage to the instrument caused by the transportation, please keep the package. With the transportation department or our distributor responsible for this business informed about it, a repairing or replacement of the instrument will be arranged by us.

235 mm · 110 mm


(VC-7200BT, for example)
Unfold the foot stool on the bottom of the multimeter.

Figure 2-1 Front panel overview (VC-7060BT, for example)
1 LCD Display the user interface
2 Menu selection Keys Activate the corresponding menu
Save Collect data in manual record. The instrument saves current reading each time the Save key is pressed. See page 12, Manual Record.
295 mm · Item Name Description · 3 Operation Keys

Record Access menus of manual record and auto record. See page 12, Data Record Function.
Run/Stop When the trigger source is set as Auto, start or stop auto trigger. When the trigger source is set as Single, the instrument issues one trigger each time this key is pressed.
Math Perform math operations (statistic, limits, dB/dBm, REL) on the measurement results.
Utility Set the auxiliary system function, including Language, Backlight, Clock, SCPI, Set to default, System information, LCD test, Key test.
Port Set Serial, Trigger, Output connector, Net Type.
4 HI and LO Sense Terminals
Signal input terminals, used for four-wire resistance measurements.
5 HI and LO Input Terminals
Signal input terminals, used for voltage, resistance, continuity, frequency (period), capacitance, diode, and temperature test measurements.
6 Range/Direction Keys When the Range softkey is shown on the right menu, you
key to switch between auto and
manual range. Press
to enable manual range, and
increase or decrease the measurement range.
When setting a parameter, press
to move the cursor,
to increase or decrease the value.
7 Current Terminal Fuse
The rating is 10 A, 250 VAC. To replace the fuse: Turn off the multimeter and remove the power cord. Use a flat-blade screw driver to turn the fuse holder counter-clockwise, and pull out the fuse holder. Put the new specified fuse into the fuse holder, and insert the assembly back into the instrument, turning the fuse holder clockwise to lock it in place.
8 AC/DC Current Input Terminals
Signal input terminals, used for AC/DC current measurements.
9 Power button Turn on/off the multimeter.
can press the · press

10 Measurement Function Keys
DC or AC voltage measurements
DC or AC current measurements
Resistance, continuity, and diode measurements
11 Graph Choose what is displayed: number, bar meter, trend chart, or histogram.
12 Dual Press this key to display the function list on the right menu, select a function, if the function is supported, the reading will be displayed in the Vice Display.
13 USB Connector Connect with an external USB device, such as connect a USB memory device to the instrument.

Figure 2-2 Rear panel overview
1 External Trigger Input
Trigger the multimeter by connecting a trigger pulse. The external trigger source must be selected. (
→ Trigger → Source (External) )

2 Auxiliary Output Connector
Defaults to Voltmeter Measurement Complete Output, outputs a pulse whenever the multimeter finishes taking a measurement to allow you to signal other devices. This connector can also be configured to output a pulse when limits are exceeded in Math limits function (
→ Output → Output (P/F)).
3 RS232 Connect the PC through this interface.
4 USB (type B) Connector
This can be used to connect a USB type B controller. Connect with an external device, such as connected to a PC and controlled via PC software.
5 Local Area Network (LAN) Connector
The multimeter can be connected to the network for remote control via this connector.
6 Line Fuse The fuse rating is 250 V, F0.5AL. To replace the fuse, see page 17, Appendix C: Line Fuse Replacement.
7 AC Mains Input AC mains input connector.
8 Chassis Ground Screw
To ground the chassis.
9 Instrument Cable Lock
You can lock the instrument to a fixed location using the security lock (please buy it yourself) to secure the instrument.


Trigger Mode Status Icon
Ext Trigger External trigger
Connect as a slave device with PC
Auto record function is running
USB memory device is detected
Figure 2-3 User interface (Single display)

Primary function Figure 2-4 User interface (Dual display)
(1) Connect the instrument to the AC supply using the supplied power cord.
(2) Press down the power button at the front panel, the screen shows the boot screen.
After selecting the desired measurement function, please connect the signal (device) under test to the multimeter according to the method below. To avoid instrument damage, do not discretionarily switch the measurement function when measuring.




Open or Closed Circuit

Data record function includes manual record and auto record. You can use any or both functions to record the data.
key to save current reading to internal memory. The maximum number of readings is 1000. Once you have finished collecting data, you can view it in table, and export it to external memory.
Auto record: After setting memory, number of readings, sample interval, press the Start softkey to start recording. You can view the data in internal memory in table or graph.
icon will show up on the top of the display.
key is pressed. The instrument beeps, and the
key, press the Manual record softkey to display the data table. Press
keys to turn the page. (When the data table is shown, you can still save current reading by pressing the
key.)
When the recording data exceeds the current range, the data will be marked as

"overload".
"rel" in the table indicates the relative operation is turned on.

key, press the Auto record softkey.
Press the Memory softkey to select internal or external memory
Press the Points softkey to specify the total number of readings to record. The range is 1 to 1 M for internal memory, 1 to 100 M for external memory.
Press the Interval softkey to specify the time interval between readings. The range is 5 ms to 1000 s.
icon will show up
on the top of the display. Press the Stop softkey to stop recording, the data will be saved in the specified memory as a CSV file. If the external memory is selected, the file will be saved in \Record\Auto folder in USB memory. The file name is Data_YYYYMMDD_HHMMSS, YYYYMMDD is the data recording start date, HHMMSS is the start time, e.g. Data_20160804_095622.csv. Note:
When the auto recording mode is running, press another measurement function
key, the instrument will display a message "Press the key again to switch function and stop recording.". If you want to continue auto recording, just wait until the message disappears. If you want to stop auto recording and switch to the function, press the function key again when the message is still displayed. The recording data before switching the function will be saved.
In auto range, the relay switch may cause jitter, the data at this time is invalid. It

will last about a few hundred milliseconds, and the data acquired in this period will be marked as "invalid".
When the dual display is enabled, only the reading of main display function can be
saved.
key, press the View record softkey. Memory can only be internal memory. Press the Display softkey to select Table or Graph to display the readings.
Press the Read softkey to read and view the auto record file in the internal memory. (If the data is viewed in table, press
keys to turn the page.)

Auto recording data displayed in graph

Auto recording data displayed in table

If you encounter other problems, try to reset the settings or restart the instrument. If it still cannot work properly, please contact us for our service, and provide your device
information. (
→ Next → System Info)

3.Appendix
Standard Accessories (subject to final delivery):







Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time.
To clean the instrument exterior, perform the following steps:
the instrument has already been dried completely, avoiding any electrical short circuit or bodily injury resulting from the moisture.

3.Appendix
The line fuse is in the plastic fuse box below the power line input on the rear panel.
connected to the instrument before replacing the line fuse. Failure to do so could expose the operator to hazardous voltages that could result in personal injury or death.
Use only the correct fuse type. Failure to do so could result in personal injury or instrument damage.
To perform the line fuse replacement, follow these steps:

Voltage Fuse
Owners and our team usually reply within a day — and your question helps the next person too.