Connect the device to the included PoE injector with Ethernet cable;
Connect the PoE injector into the PC or to the network switch;
Connect the power adapter to the PoE injector; Download WinBox configuration tool https://mt.lv/winbox
Open WinBox and connect to the device; Default IP: 192.168.88.1, user name: admin and there is no password; Download the latest RouterOS software from https://mikrotik.com/download
Choose ARM packages, and save them to your PC;
Open WinBox and upload downloaded packages, drag and drop into any windows;
Restart the device; Connect again and select your Region in the Wireless menu, W60G tab, and in QuickSet menu set your
Country, to apply country regulation settings.
If the device RX blocking condition has happened device will restore its signal after a few seconds. MikroTik mobile app
Use the MikroTik smartphone app to configure your router in the field, or to apply the most basic initial
settings for your MikroTik home access point.


of easy steps.
Once logged in, we recommend clicking the "Check for updates" button in the QuickSet menu, as
updating your RouterOS software to the latest version ensures the best performance and stability. For
wireless models, please make sure you have selected the country where the device will be used, to
confirm with local regulations.
RouterOS includes many configuration options in addition to what is described in this document. We
suggest starting here to get yourself accustomed to the possibilities: https://mt.lv/help In case an IP
connection is not available, the Winbox tool (https://mt.lv/winbox) can be used to connect to the MAC
address of the device from the LAN side (all access is blocked from the Internet port by default).
For recovery purposes, it is possible to boot the device from the network (see Reset button).
If the device loses connection, wait for few seconds and then the device will recover connection
Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be
familiar with standard practices for preventing accidents.
Read the installation instructions before connecting the system to the power source.
This equipment is to be installed by trained and qualified personnel, as per these installation
instructions. The installer is responsible for obtaining any required local or national safety inspections of
the structural integrity of the installation by the local authority/inspection department.
All installation methods for mounting an access point on any wall surface is subject to the acceptance of
local jurisdiction.
The Installation of the equipment must comply with local and national electrical codes.
This unit is intended to be mounted outdoors on a pole. Please read the mounting instructions carefully
before beginning installation. Failure to use the correct hardware and configuration or to follow the
correct procedures could result in a hazardous situation to people and damage to the system.
We cannot guarantee that no accidents or damage will occur due to the improper use of the device.
Please use this product with care and operate at your own risk. Assembly and mounting
The device can be mounted on the vertical or horizontal pole as shown in pictures A and B. Please note
that a device needs to be mounted with the bottom latch facing down. The maximum pole diameter is
51 mm.
Mounting and configuration of this device should be done by a certified person.
Choose your desired position, the device will require precise adjustment for best performance.

you can adjust in a 23-degree range if an adjustment needs to go further replace the screw in a
different position.

The IP rating scale for this device is IP54. When mounting outdoors, please ensure that any cable
openings are directed downwards. We recommend using the POE injector and proper grounding with
Cat6 shielded cable. When using and installing this device please pay attention to the Maximum
Permissible Exposure (MPE) safety distance with a minimum of 20 cm between the radiator and your
body.
Alternatively, the device can be mounted on one of the three mounting slots on the backside of the
device.


You can use a metal ring for example.

Use a Phillips screwdriver to loosen the metal ring.
Slide one end of it through the most convenient of the three mounting slots.
Position the device on the pole where it will be mounted.
Slide the loose end of the mounting ring back to its closing latch and use the screwdriver to tighten it.
It's recommended to secure Ethernet cable to the pole using zip ties. With the distance from the device
approximately 30 cm.
As an additional option, you can use "quickMOUNT-X" – mounting bracket for an easy adjustment that
can be obtained separately. Product web page: https://mikrotik.com/product/qm_x

The device includes a grounding connection (marked ) which you should connect to the grounding ⏚
installation of the tower or building where the device will be used. This is to substantially reduce the risk
The device accepts DC power from Passive PoE injectors (one power supply and PoE injector are ⎓
included) accepts 12-28 V DC consuming at maximum load 4 W. ⎓
Connecting to a PoE Adapter:
10/100 Ethernet port.
Integrated 5 GHz 802.11a/n/ac interface with built-in antenna.
WiGig chipset QCA6335.

The routerBOOT reset button has the following functions. Press the button and apply the power, then:
Release the button when green LED starts flashing, to reset RouterOS configuration to defaults.
Release the button when the LED turns solid green to clear all configuration and defaults.
Release the button after LED is no longer lit (~20 seconds) to cause the device to look for Netinstall
servers (required for reinstalling RouterOS over the network).
Regardless of the above option used, the system will load the backup RouterBOOT loader if the button
is pressed before power is applied to the device. Useful for RouterBOOT debugging and recovery. Accessories
Package includes the following accessories that come with the device:
EU/US Switching Power Supply 24V DC , 0.8 A, 9 W, Level VI, cable:1.5 m. ⎓
POE Injector with shielded ethernet cable/connector (RBPOE).
Cube mount.
K-70 Fastening set for Cube mount.
The device supports RouterOS software version v6.47.2. The specific factory-installed version number is
indicated in the RouterOS menu /system resource. Other operating systems have not been tested. Notes
This device meets the Maximum TX power limit per ETSI regulations. The frequency and the maximum
transmitted power in the EU are listed below: 57-66GHz: 34.92 dBm. An Operational mode in the 60
GHz band: 58.32 GHz, 60.48 GHz, 62.64 GHz, 64.80 GHz. This device is certified for outdoor use in Point
to Multipoint applications. In the following countries this device cannot be used in Fixed Point-to-Point
applications:


This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a commercial installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device is not to be operated on aircraft except for the conditions listed on FCC CFR §15.255 (b)
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 21cm between the
radiator & your body.
All cables used to connect peripherals must be shielded and grounded. Operation with cables
connected to peripherals that are not shielded and grounded may result in interference to radio and
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and
Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two
including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes : 1) L’appareil ne doit pas produire
de brouillage; 2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.

This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.
This device is not to be operated on aircraft except for the conditions listed on ISED RSS-210 Annex J.1.
Cet appareil ne doit pas être utilisé sur un avion, sauf dans les conditions énumérées ISED RSS-210
Annex J.1.
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance 21cm between
the radiator & your body.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 21cm de
distance entre la source de rayonnement et votre corps. CE Declaration of Conformity


Operating Frequency / Maximum output power
Betriebsfrequenz / maximale Ausgangsleistung
Fréquence de fonctionnement / puissance de sortie
Frequenza operativa / massima potenza di uscita
5470-5725 MHz / 27 dBm
Frecuencia de funcionamiento / potencia de salida máxima
Рабочая частота / максимальная выходная мощность
maximale
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.