EN
Element4 logo
Official user manual

Element4 Electric Fires

12 pages·1.3 MB·Fireplace·PDF·ENDEFRITNLJA
Element4 Electric Fires
Table of Contents 24 sections For all “Element4 - Electric Fires” INSTALLATION MANUAL · LEAVE THESE INSTRUCTIONS WITH THE DEVICE · Content · 1 CE statement 4 · … ShowHide
Page 1 of the Element4 Electric Fires user manual — LEAVE THESE INSTRUCTIONS WITH THE DEVICE
Page 1 · click to enlarge
Page 1

For all “Element4 - Electric Fires” INSTALLATION MANUAL

Element4 Electric Fires — For all “Element4 - Electric Fires” INSTALLATION MANUAL diagram (page 1)
Fig. 1 · For all “Element4 - Electric Fires” INSTALLATION MAN…

LEAVE THESE INSTRUCTIONS WITH THE DEVICE

Page 2 of the Element4 Electric Fires user manual — For all “Element4 - Electric Fires” INSTALLATION MANUAL
Page 2 · click to enlarge
Page 2
Page 2 of the Element4 Electric Fires user manual — For all “Element4 - Electric Fires” INSTALLATION MANUAL
Page 3 of the Element4 Electric Fires user manual — Content
Page 3 · click to enlarge
Page 3

Content

1 CE statement 4

2 Waranty 4

3 Important safety information 5

4 Connection 5

5 Installation method 6

6 Hollow wall installation method 6

7 The One-Box System 8

8 Decorating the fireplace 10

9 User Instructions 10

10 Troubleshooting 11

Page 4 of the Element4 Electric Fires user manual — 1 CE statement
Page 4 · click to enlarge
Page 4

1 CE statement

2 Waranty

We hereby declare that the design and construction of the Element4 electric appliances are complying to the essential demands and regulations for electric products.

Should this device show defects within 24 months of purchase due to shortcomings in construction, material or workmanship, the product will be repaired free of charge under the following conditions:

Product• Electric fire

It is the responsibility of the buyer to prove that the device is covered by the warranty, e.g. with a proof of purchase.

  • Models:
  • 50e
  • 80He
  • 80XHe
  • 100e
  • 150e
  • 150He
  • 180e

Any guarantee will lapse if

  • unauthorized repairs or modifications have been made to the electric fireplace
  • in the event of an accident, misuse or damage caused by an incorrect installation
  • damage occurred during transport to or from the
  • repairer, and changed or missing serial numbers.
  • All Element4 Electric fires meet the requirements of the EC Directives. These directives have been met by compliance with the following standard
  • EN 55014-1:2006 + A2:2011
  • EN 55014-2:2015
  • EN 61000-3-2:2014
  • EN 61000-3-3:2013
  • EN 60335-1:2012 + A1:2014
  • EN 60335-2-30:2009+A11:2012

Parts replaced under this warranty will become our property.

The company is not liable for consequential damage or any other damage arising from or related to this electric fireplace.

This warranty does not apply to heating elements, lamps or fuses. Service visits where no errors are found and installation errors are not covered by the manufacturer’s warranty. In this case, the maintenance technician employed by us will charge you for the service visit.

This declaration loses its validity when changes to the device are made without the written permission by Element4. You can ask for a copy of the test certificates of all models via our general e-mail adress, which is found on the back of this manual.

This guarantee is an addition to and does not affect the legal rights of the buyer as a consumer.

Replacement plug Caution: when removing the molded plug and connection to a fused tap through a unqualified person, the guarantee will lapse.

J. Kempers CEO

Page 5 of the Element4 Electric Fires user manual — 3 Important safety information
Page 5 · click to enlarge
Page 5

3 Important safety information

4 Connection

Please read these instructions before installation or use and keep this booklet handy for future reference

This appliance must only be connected to a 230/240 Volts AC 50Hz supply. Before connecting the fire, check that the supply voltage is the same as stated on the fire.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision

This appliance must only be used on a AC supply, fuse rating 13Amp. The wires in the mains lead are coloured in accordance with a standard UK supply, these being:

  • GREEN/YELLOW – EARTH
  • BLUE – NEUTRAL
  • BROWN – LIVE

As the colours of the mains lead of this appliance may not match the coloured markings used to identify the terminals in a plug, please observe the following

The instructions shall state that the heater must not be located immediately below a socket outlet.

  • The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or Earth symbol.
  • The blue wire must be connected to the terminal in the plug which is marked with the letter N.
  • The brown wire must be connected to the terminal in the plug marked with the letter L.
  • Replace fuses only with fuses of the correct size and rating.

Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.

Maintenance Maintenance to this device may only be done by a qualified professional. It is adviced to maintain your fire at least once every 12 months.

WARMING: Before reparation or maintenance check whether the fire is unplugged.

4.1 Important electrical safety

  • General Warnings:
  • Never leave children unsupervised with an unguarded heater.
  • Never obstruct or cover the heater outlet.
  • Never install or use this product where it may come in contact with water i.e. a bathroom or wet room.
  • Never use aerosols or steam cleaners near this product.
  • Never route the electric cable near the heater outlet.
  • Never route the electric cable under carpets or floor coverings.
  • Never install this product close to curtains or combustible materials.
  • Never use the heater to dry clothes or other objects.
  • Never remove the fireplace surrounding without isolating the electric supply.

This appliance must never be installed above or in front of a fixed electric socket.

The electrical socket must be easily accessible to isolate the supply during maintenance and cleaning.

This appliance is supplied with a two meter power lead, which has a 13Amp moulded three pin plug to connect to a standard 230/240V plug socket.

This appliance must always be earthed. If in any doubt consult a suitably competent person.

NB: This fireplace may not be used as a primary heat source.

Page 6 of the Element4 Electric Fires user manual — 5 Installation method
Page 6 · click to enlarge
Page 6

5 Installation method

6 Hollow wall installation method

Built in models This product has been designed to be installed into a plaster board, or existing masonry chimney breast. Please seek advice from a professional, with reference to the structural integrity of the installation site.

In all Element4 fireplaces, a free space of 100mm at least 50mm must be maintained immediately above and below the main housing for good air circulation. (Failure to do so may cause problems for the heating and flame function).

Each Element4 fireplace is supplied with one or more wall mounting brackets.

If the product is to be installed into a open chimney or flue, it is important that the chimney/flue is blocked off to prevent any up/down draughts and falling debris which could restrict and alter the airflow to the product.

Determine the height at which the finished Element4 fireplace should be positioned in relation to the floor level.

It is also important to ensure that the product has a minimum internal clearance directly above and below the product of 50mm, this is to ensure that the product can circulate the required airflow for the heater unit.

Attach the wall bracket to the wall, making sure that you use the correct fasteners that match the respective wall - hollow or solid.

The product should never be sealed into a opening with the use of silicones or adhesives as this can also alter the airflow and hinder any further servicing of the product Heating shut-off protection This protection protects the product against damage.

Hang the Element4 fireplace on the bracket and secure it in place with the wall bracket at the top of the fireplace. Insert the plug of the IEC-compliant power cable into the IEC- compliant socket and ensure that it is firmly pushed.

When the air circulation is impeded, the fire is switched off automatically. This can happen with incorrect installation of the fireplace, or blockages.

To reset the heating function:

It is important that the outlet is located outside the installation location so that the socket is easily accessible and the plug can be disconnected from the stove after installation. After the fire is attached to the wall and connected to the socket, the surround (the chimney) can be placed around it.

  • Remove the plug from the socket.
  • Allow the product to cool.
  • If the device has cooled down sufficiently, remove any blockages and check the installation.

Construct the hollow installation space for the electric fire in the desired dimensions. For minimum opening dimensions, see Figure 1 and Table 1.It is important that you take into account the finished front when determining the depth of the frame construction.

After 10 minutes, the thermostat switch (trip protection) of the heater is reset.

It is important that a header/lintel is also placed at the desired height, so that the weight of the wall made will not come to rest on the appliance.

Make the cut in the plasterboard / finishing plate and install the fireplace, making sure that the plaster board edges connect to the inside of the cut in the plate. CAUTION In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.

Page 7 of the Element4 Electric Fires user manual — 5 Installation method
Page 7 · click to enlarge
Page 7
Element4 Electric Fires — 5 Installation method diagram (page 7)
Fig. 2 · 5 Installation method

The definite opening dimensions after installation are in the table below

Element4 Electric Fires — 5 Installation method diagram (page 7)
Fig. 3 · 5 Installation method
ModelWidth (mm)Depth (mm)Height (mm) 50495305610 80H802305590 80XH838.53161209 1001003305355 1501505305355 150H1538316808 1801750305410
Element4 Electric Fires — 5 Installation method diagram (page 7)
Fig. 4 · 5 Installation method
Page 8 of the Element4 Electric Fires user manual — 7 The One-Box System
Page 8 · click to enlarge
Page 8

7 The One-Box System

Every Element4 electrical appliance is delivered to the customer according to the so-called one-box system. This means that the customer can choose from four configurations per fireplace type, depending on which sides of the fireplace have glass or not. These four models are respectively the front model, two corner models and a three-sided model.

Make sure the following parts are included in the box.

ITEMDESCRIPTIONQuantity 1 2 3 4 5 6 7 8 9 10 11 12 13 14Side glass Front glass Plaster kit (3 off left side, 3 off right side) Main housing Front glass bottom support Front glass bottom retainer Front glass bottom retainer fixings Fuel bed Side glass top retainer (internal) Side glass top retainer (internal) fixings Plaster kit fixings In-fill side piece fixings In-fill right side In-fill left side2 off 1 off 6 off 1 off 1 off 1 off 2 off 1 off 2 off 4 off 16 off 16 off 1 off 1 off

This chapter explains the various steps with which the customer can put together the desired configuration. The fireplace is supplied as a three-sided model as standard.

Please note: Check for the possible conversion of your fireplace first the contents of the box.

In the table on the right and on the next page see all the parts which are supplied in the box.

Removal of the front glass (item 2)

Removal of the plaster kit (item 3)

Remove the plaster kit fixings (item 11) using a phillips screw driver (not supplied)

Remove the 2 off fixings (item 7) that secure the front glass bottom retainer (item 6) to the fuel bed (item 8).

Lift off the front glass retainer (item 7) and using the glass suckers supplied (not shown) carefully remove the front glass (item 2).

Remove the plaster kit (item 3) from both sides of the unit.

Removal of the side glass (item 1)

Fitting in the in-fill sides (item 13 and item 14)

Remove the 2 off side glass top retainer brackets (item 9) by taking out the 4 off fixings (item 10). 2 off on each bracket.

Remove the In-fill side fixings (item 12)

Place the in-fill sides over the existing side pieces

Using the in-fill side fixings (item 12) together with the plaster kit fixings (item 11) that were removed in the previous step secure the left and right in-fill sides (item 13 and 14) to the unit.

Carefully tilt the side glass inwards at the top and lift it away from unit.

Show 6 more labels / short text on this page
Part List · Conversion steps · Step 1; · Step 3; · Step 2; · Step 4;
Page 9 of the Element4 Electric Fires user manual — 7 The One-Box System
Page 9 · click to enlarge
Page 9
Element4 Electric Fires — 7 The One-Box System diagram (page 9)
Fig. 5 · 7 The One-Box System
Page 10 of the Element4 Electric Fires user manual — 9 User Instructions
Page 10 · click to enlarge
Page 10

8 Decorating the fireplace

Element4 Electric Fires — 8 Decorating the fireplace diagram (page 10)
Fig. 6 · 8 Decorating the fireplace

Removing glass front side

Follow the next steps for temoving the glass front window and place the decorative logset.

1. Remove the two screws located in the bottom glass retaining bar.
2. Remove the bottom glas retaining bar.
3. Remove the glass by pulling the second retaining bar away from the body of the fire, ensure that the glass is supported at all times.
Element4 Electric Fires — 8 Decorating the fireplace diagram (page 10)
Fig. 7 · 8 Decorating the fireplace

Suction cup A suction cup is provided to help aid this step. Please note the suction cup is not to hold the full weight of the glass. Tip It is recommended with the 150e and 180e models to carry out these steps with two persons.

4. Place the log set as stated below and replace the glass in reversed order of step 1 to 3.

Placing the logset Every models is deliverd standard with a European logset. The style and size of the set varies between models.

The logs can be arranged to personal preference and o not influence the flames or the proper functioning of the fire.

9 User Instructions

The Element4 electric fires can be used with the Element4 Electric fire application available on Android and iOS.

For a full instruction on how to use your electric fires we refer you to the user manual.

Show 4 more labels / short text on this page
Step 1 · Step 2 · Step 3 · Step 4
Page 11 of the Element4 Electric Fires user manual — 10 Troubleshooting
Page 11 · click to enlarge
Page 11

10 Troubleshooting

ProblemPossible CauseSolution Flames not working correctlyRibbons are statically connected to glass.Spray some anti-static spray beneath the tray. Installation airflow restricted.Check the correct aperture has been adhered to when installing— Recommended clearance is 100mm. Blower clogged.Fan requires cleaning out. Slow fan.Fan requires cleaning out. If problem persists, replacement fan may be required. Heater blowing coldPossible installation gaps/Chimney not adequately blocked of.fChimney may not be fully blocked. Correct aperture has not been adhered to—100mm Fan clogged.Heater fan requires cleaning out Faulty element.Replace element Slow fan.Check fan placement. If problem persists replacement fan may be required. Noisy HeaterFan unbalanced.Adjust fan to stop catching on the case. If problem persists replacement fan unit maybe required. Fan catching on housing.Adjust fan to stop catching on the case Fan clogged.Fan requires cleaning out. If problem persists a replacement fan may be required. Fan has come loose.Tighten fan cradle or screws holding fan onto fan cradle. Heater coming on randomlyTimer has been accidentally set.Double check timer settings. Thermostat faulty.Replace PCB. LED streakingLED dropped down.LED needs to be re-stuck into place. Log positioning.Change log positioning to hide any direct view of LED strip. Heater cutting outBuild up of hot air triggering heater cutout unit.Ensure the appliance has the required aperture for air to circulate and prevent build-up. Recommended 100mm
Page 12 of the Element4 Electric Fires user manual — 20/01/20
Page 12 · click to enlarge
Page 12
Element4 Electric Fires — 20/01/20 diagram (page 12)
Fig. 8

ELEMENT 4 B.V.

Paxtonstraat 23 8013 RP Zwolle The Netherlands [email protected]

www.element4.nl

20/01/20

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Flames not working correctlyRibbons are statically connected to glass.Spray some anti-static spray beneath the tray. p.11
Flames not working correctlyInstallation airflow restricted.Check the correct aperture has been adhered to when installing— Recommended clearance is 100mm. p.11
Flames not working correctlyBlower clogged.Fan requires cleaning out. p.11
Flames not working correctlySlow fan.Fan requires cleaning out. If problem persists, replacement fan may be required. p.11
Heater blowing coldPossible installation gaps/Chimney not adequately blocked of.fChimney may not be fully blocked. Correct aperture has not been adhered to—100mm p.11
Heater blowing coldFan clogged.Heater fan requires cleaning out p.11
Heater blowing coldFaulty element.Replace element p.11
Heater blowing coldSlow fan.Check fan placement. If problem persists replacement fan may be required. p.11
Noisy HeaterFan unbalanced.Adjust fan to stop catching on the case. If problem persists replacement fan unit maybe required. p.11
Noisy HeaterFan catching on housing.Adjust fan to stop catching on the case p.11
Noisy HeaterFan clogged.Fan requires cleaning out. If problem persists a replacement fan may be required. p.11
Noisy HeaterFan has come loose.Tighten fan cradle or screws holding fan onto fan cradle. p.11
Heater coming on randomlyTimer has been accidentally set.Double check timer settings. p.11
Heater coming on randomlyThermostat faulty.Replace PCB. p.11
LED streakingLED dropped down.LED needs to be re-stuck into place. p.11
LED streakingLog positioning.Change log positioning to hide any direct view of LED strip. p.11
Heater cutting outBuild up of hot air triggering heater cut- out unit.Ensure the appliance has the required aperture for air to circulate and prevent build-up. Recommended 100mm p.11

Ask about the Element4 Electric Fires

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Element4 Electric Fires

Be the first to ask — other owners or our team will answer.

Original document

Element4 Electric Fires manual PDF

12 pages·1.3 MB·Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…