Braun
Commercial
RA300 Transit Ramp
RA300 Transit Ramp
for Low-Floor Transit Vehicles

Read manual before operating, installing or servicing ramp. Failure to do so may result in serious bodily injury and/or property damage.
® · March 2007

We at The Braun Corporation wish to express our fullest appreciation on your new purchase.
With you in mind, our skilled craftsmen have designed and assembled the finest ramp available.
This manual includes operating instructions, installation instructions, servicing instructions and instructions for troubleshooting, if needed.
Braun ramps are built for dependability and will provide years of service and mobility independence, as long as the ramp is installed and maintained as specified, and the ramp is operated by an instructed person.
THE BRAUN CORPORATION
Ralph W. Braun Chief Executive Officer



Refer to the illustration below and the illustrations on SDJHIRULGHQWLÀFDWLRQRIFRPSRQHQWVDQGFODULÀFD- tion of direction terminology. Details regarding lift model variations, terminology, direction and compo- nents are provided on pages 4 and 5.
RIGHT
LEFT
OUT
As viewed from outside the vehicle


(BF3248Y & BF3748Y Only)
Assembly (BF3248Y & BF3748Y Only)
Pump Ramp Drive Arm

Assembly (BF3248Y & BF3748Y Only)
IN
RIGHT
As viewed from outside the vehicle

Braun RA300 Series Transit Ramps (to be referred to as RA300 throughout this manual) DUHGHVLJQHGIRUXVHLQORZÁRRU transit vehicles. The RA300 provides vehicle access to people with disabilities (wheelchair pas- sengers or standees using other type mobility aids). The commer- cial oriented ramp is ADA compli- ant (dependant upon installation height). See the Installation sec- WLRQIRU$'$VSHFLÀFDWLRQV
The RA300 provides fully auto- matic operation of ramp functions. The electric/hydraulic system is controlled by two relays which ac- tivate the hydraulic pump in oppo- site directions for deploy and stow functions (powering a dual-acting hydraulic cylinder). No sensitive electronic controls or sensors are required for operation.
Instructions are provided for manual operation of the ramp in event of power or equipment failure. See Manual Override on the following page for further details.
Read and become familiar with all operation safety precautions, pre-operation notes and details, operating instructions and manual operating instructions before at- tempting operation.
All RA300 ramp models feature gravity down "drift" during the deploy cycle. When deploying the ramp, the motor stops running when the ramp reaches an ap- proximate 45° angle. The ramp continues to slowly lower the remaining distance by the force of gravity.
Terminology: Become familiar with the terminology that will be used throughout this manual. Become familiar with the iden- WLÀFDWLRQRI5$FRPSRQHQWV and their functions. Contact your sales representative or call The Braun Corporation at 1-800-THE LIFT® if any of this information is not fully understood.
The self-contained “drop-in” unit requires no remote pump, exter- nal hydraulic lines or pre assem- bly. The hydraulic and electrical components are internal and eas- ily accessible. A single electrical feed provides the power supply (12 volt or 24 volt), the ground, a ramp OUT signal (+), a ramp IN signal (+) and various indicator signals.
5DPSPRGHOQXPEHUVZLWKVXIÀ[ "Y" are hydraulic fold with gravity down "drift" feature when deploy- ing and stowing. When stowing the ramp and it folds inward be- yond the 15° shut off point, gravity lowers the ramp to the pan.
Direction: The terms “left”, “right”, “in” and “out” will be used throughout this manual to indicate direction (as viewed from the out- side of the vehicle looking directly at the ramp). Refer to the Termi- QRORJ\,OOXVWUDWLRQVIRUFODULÀFDWLRQ of direction terms.
The RA300 features a 32” wide ramp in a 34” wide package. A ´ÁRRUSRFNHWµEXLOWLQWRWKHFKDV- VLVÁRRUV\VWHPDOORZVIRUVLPSOH installation (dimensional require- PHQWVVSHFLÀHGLQWKH,QVWDOODWLRQ section).
Ramp model numbers with suf- À[
7KH5$LVVSHFLÀFDOO\GH- signed to be operated by an attendant. The ramp installer provides an appropriate control switch for the end user. Con- squently, the operating instruc- tions contained in this manual are generic due to the limitless variables.
The pressure relief valves built into the pump prohibit the ramp from lifting (raising) with approxi- mately 20 pounds or more on the ramp.

Refer to the Terminology Illustra- tions on pages 2 and 3.
components from above. The cover is easily removed for ac- cess to drive components. The VXEÁRRUSURYLGHVDQDQWLVNLG surface for entry and exit when the ramp is deployed. The RA300 stows (folds) onto the sub ÁRRUSURYLGLQJDQXQREVWUXFWHG antiskid surface for entry and exit when the ramp is not in use.
Ramp Assembly: The ramp assembly is made of an inboard ramp section (stage one) and an outboard ramp section (stage two). Each aluminum ramp sec- tion features vertical side plates and full antiskid surface.
Pan Weldment (Housing): The pan is the stainless steel (casing) mounted in the vehicle ÁRRUV\VWHPZKLFKFRQWDLQVWKH hydraulic pump and electrical components that power the ramp electric/hydraulic systems. The À[HGVXEÁRRUFRYHUSURWHFWVWKH
Drive Arm Assembly: The cylinder driven three stage drive arm assembly deploys and stows the ramp assembly.
Deploy: Deploy is the action of the ramp assembly extending and unfolding to ground level when the DEPLOY (OUT) switch* is activated (*installer supplied).
Stow Position: Stow position is achieved when the two stage ramp assembly is fully retracted and folded (resting fully on the pan weldment).
the ramp assembly to manually deploy or stow the ramp. Mini- mal physical effort is required to URXWHWKHK\GUDXOLFÁXLGWKURXJK the system. Slow steady motion results in the least resistance and easy operation. The faster you attempt to manually operate the ramp, the greater the resistance. See Ramp Manual Operation on page 11 for further details.
Stow: Stow is the action of the ramp assembly raising and fold- ing inward to stow position when the STOW (IN) switch* is acti- vated (*installer supplied).
Manual Override: Manual operation is achieved without the use of any mechanical release or complicated procedures. Simply use the Hand Holds provided on

SAFETY FIRST! Know That
All information contained in this manual and B W ARNING


supplements (if included), is pro- vided for your safety. Familiarity with proper operation instructions as well as proper maintenance procedures are necessary to en- sure safe, trouble free operation. Safety precautions are provided to identify potentially hazardous situations and provide instruction on how to avoid them.
This symbol indicates important safety information regarding a potentially hazard- ous situation that could result in serious bodily injury and/or property damage.
This symbol indicates important information regarding how to avoid a hazardous situation that could result in minor person- al injury or property damage.
These symbols will appear throughout this manual. Recognize the seriousness of this information.

Read manual and supplement(s) before operating ramp. Read and become familiar with all safety precautions, pre- operation notes and details, operating instructions and manual operating instructions before operating the ramp. Note: All transit agency personnel (drivers and ramp at- tendants) must read and become familiar with the con- tents of this manual and supplement(s) before operation.
If the ramp operating instructions, manual operating instructions and/or ramp operation safety precautions are not fully understood, contact The Braun Corporation immedi- ately. Failure to do so may result in serious bodily injury and/or property damage.
Load and unload on level surface only.
Engage vehicle parking brake before operating ramp.
Provide adequate clearance outside the vehicle to accom- modate the ramp before opening lift door(s) or operating ramp.
Inspect ramp before operation. Do not operate ramp if you suspect lift damage, wear or any abnormal condition.
Keep operator and bystanders clear of area in which the ramp operates.
/RDGDQGXQORDGFOHDURIYHKLFXODUWUDIÀF
W ARNING
Open ramp door(s) fully and secure before operating ramp.
Do not overload or abuse. The rated capacity is 300 kilograms (660 pounds).

Ramp Operation Safety Precautions (continued)
Do not activate control switch(es) when anyone is near the area in which ramp operates.
It is the responsibility of the attendant to oversee and assist ramp passengers.
The wheelchair passenger and/or attendant must ensure the ramp is fully deployed before exiting the vehicle.
Attendants must never operate the vehicle, the ramp or attend to passengers if intoxi- cated.
Intoxicated passengers should not be allowed to board the vehicle.
Wheelchair passengers must position and secure (buckle, engage, fasten, etc.) the wheelchair-equipped occupant seat belt before loading onto the ramp.
Be aware of the ramp slope (angle).
Wheelchair passengers should not raise front wheelchair wheels (pull wheelie) when on the ramp.
The wheelchair must be positioned in the center of the ramp when loading and unloading.
Keep ramp owner’s manual in ramp-mounted vehicle at all times.
0DLQWHQDQFHDQGOXEULFDWLRQSURFHGXUHVPXVWEHSHUIRUPHGDVVSHFLÀHGLQWKLVPDQXDO E\DXWKRUL]HG FHUWLÀHG VHUYLFHSHUVRQQHO
W ARNING
Never modify (alter) a Braun Corporation ramp.
Do not use accessory devices not authorized by The Braun Corporation.
Do not remove any guards or covers.
If the information contained in this manual is not fully understood, contact The Braun Corporation immediately.
)DLOXUHWRIROORZWKHVHVDIHW\SUHFDXWLRQVPD\UHVXOWLQVHULRXVERGLO\LQMXU\DQGRUSURS- erty damage.

The RA300 Ramp provides vehicle access to people with disabilities (wheelchair passen- gers or standees using other type mobility aids). The commercial oriented RA300 Ramp is operated by the transit vehicle driver/atten- dant. Unless your transit agency has a published policy stating that driver/attendants do not aid ramp passengers, safe entering and
exiting of ramp passengers is the responsibility of the driver/ attendant.
Read and become familiar with all ramp operation safety precau- tions, pre-operation notes and details, operating instructions and manual operating instructions before attempting ramp opera- tion procedures or assisting ramp passengers boarding and exiting the vehicle.
As stated in the Ramp Operation Safety section, all information in this manual is provided for the safety of passengers, attendants and bystanders. Recognize the seriousness of this information.
Attendants must become familiar with the vehicle ramp access door system and interlock(s), as well as the proper operation of the ramp.
Interlocks are required by nearly all transit authorities. Vehicle interlocks typically prevent vehicle motion if the ramp is not stowed. In some cases, the ramp cannot be operated if interlock conditions are not met. Interlock require- ments may include: the vehicle transmission must be engaged in Park, the parking brake must be engaged, the ramp access door must be fully open and/or others. Multiple interlocks may exist.
General instructions for safe operation of the ramp are pro- vided. Ramp safety and ramp passenger safety information is included. It is the responsibil- ity of the attendant to properly open and close the ramp access door(s), to activate interlock(s), to properly activate the ramp power functions as well as assist ramp passengers.
Vehicle ramp access door con- ÀJXUDWLRQVDQGRSHUDWLRQSURFH- dures vary. Ensure the ramp door is fully open before activating the ramp (an interlock typically pre- vents ramp operation unless the door is fully open). Attendants and passengers must keep clear of the area in which the power door operates. Ensure the path is clear before closing the door. Be sure the door is fully closed before attempting to drive the ve- hicle (interlocks typically ensure this).
Do not operate the ramp if you suspect ramp damage, wear or any abnormal condition. Dis- continue use immediately and contact The Braun Corporation at 1-800-THE LIFT®. One of our national Product Support repre- sentatives will direct you to an authorized service technician who will inspect the ramp.
Instructions for operation of interlocks and door systems will not be addressed in this manual due to the variety of procedures required for operating them.

The Braun Corporation recom- mends that transit agency su- pervisors and driver/attendants review the safety precautions and operation procedures appearing in this manual with the ramp sales representative (or vehicle con- verter) before attempting ramp operation.
Transit agency supervisors should train and educate all driver/attendants on the proper use and operation of the vehicle, door system, interlock(s), ramp and ramp passenger safety.
Read and become familiar with all ramp operation safety precautions, pre- operation notes and details, operating instructions and manual operating instructions prior to operating the ramp. If this information is not fully understood, contact The Braun Corporation immedi- ately. Failure to do so may result in serious bodily injury and/or property damage.
The ramp owner’s/service manu- al must be stored in the ramp- equipped vehicle at all times.
Any questions or concerns can be answered at that time. Operate the ramp through all functions to ensure the proper use and opera- tion is understood.
Preventive Maintenance:
Maintenance is necessary to ensure safe and trouble free operation. General preventive maintenance consisting of care- ful inspections and cleaning the ramp system should be a part of your transit agency’s daily service program. Simple inspections can detect potential operational problems.
Regular preventive maintenance will reduce potential operation downtime and increase the service life of the ramp, as well as possibly detecting potential hazards.
Exposure to harsh weather, en- vironmental conditions, or heavy usage may require more frequent maintenance and lubrication procedures.
A generic Daily Preventive Main- tenance Schedule is provided in this manual for your transit agen- cy’s use. The form can be tailored to your particular application.
Preventive maintenance visual inspections do not take the place RIWKHSURFHGXUHVVSHFLÀHGLQ the Maintenance and Lubrication Schedule provided in this manual. Refer to the Maintenance and Lubrication section in this manual for further details.

The power ramp is attendant operated and activated by the control switch provided by the vehicle con- verter (ramp installer). A momentary contact ramp control switch (center off) will typically be provided near the driver. The control switch may be part of a panel providing other features and controls (power on/off indicators, LED’s, etc.).
Before operating the ramp, park the vehicle on DOHYHODUHDDZD\IURPYHKLFXODUWUDIÀF3ODFH the vehicle transmission in “Park” and engage the parking brake. Meet all other interlock conditions (as equipped). Activate the vehicle “kneel” system to lower the vehicle (if so equipped). Lowering the vehicle reduces the slope of the ramp.
Be certain there is adequate clearance outside the vehicle before deploying the power ramp.
be aware of any special needs and/or procedures required for safe transport of wheelchair passengers.
Provide adequate clearance outside of vehicle to ac- commodate ramp. Failure to do so may result in serious bodily injury and/or property damage.
Do not attempt to load or unload a passenger in DZKHHOFKDLURURWKHUDSSDUDWXVWKDWGRHVQRWÀW on the ramp. Do not exceed the 660 pound (300 kilograms) load capacity of the ramp. Passengers should enter and exit one at a time. The attendant should not board the ramp with the passenger except when assistance is required and the load capacity is not exceeded. Always return the ramp to the stowed position when not in use.
The ramp opera- tor (attendant) and bystanders must keep clear of the area in which the ramp operates and clear of all mov- ing parts. Attendants must ensure that passengers keep clear of the area in which the ramp operates. Do not attempt to grip or hold the ramp, ramp drive arm assemblies or the tension cables.
Keep clear of area in which ramp operates.
If you are an attendant operating the ramp, it is your responsibility to oversee and/or assist in performing safe passenger loading and unloading procedures. Observe your passengers at all times when they are entering and exiting the vehicle. Attendants must
Deploy Gravity Down Drift (All RA300 models):
Stow Gravity Down Drift ("Y" ramp models only):
When deploying (unfolding) the ramp, the ramp pump motor stops running when the ramp reaches an approximate 45° angle (shut off point). The ramp continues to slowly lower the remaining dis- tance by the force of gravity (non-powered).
When stowing the ramp and it reaches an approxi- mate 15° angle (shut off point), gravity lowers the UDPSWRWKHSDQ ÁRRU
Allow the ramp to unfold (deploy) fully before boarding the ramp. Forcing the ramp out or down during the deploy (unfold) function, or boarding onto the ramp before it is fully-deployed may re- sult in damage to the ramp and/or drive assembly.
Allow ramp to deploy fully before boarding. Failure to do so may result in damage.

If you experience power or equipment failure, the ramp can be manually stowed and deployed. The RA300 ramp must be manually operated by an at- tendant.
Keep clear of area where ramp side plates VWRZLQSDQ ÁRRU
Keep clear of hinged areas.
Two oval-shaped HAND HOLD slots are provided on the ramp (see Figure A). Carefully unfold and fold the ramp using the HAND HOLDs.

Keep clear of tension cables.
Keep clear of the area in which the hinged RA300 ramp sections fold and unfold. Keep clear of the area where the inboard ramp side plates stow in the SDQ ÁRRU .HHSFOHDURIWHQVLRQFDEOHVDQGGULYH arms. Remember to use good body mechanics when folding and unfolding the ramp.
The safety precautions addressed in the Ramp Power Operation section apply to manual operation of the ramp also. Read and become familiar with all ramp safety precautions.
Keep clear of hinged areas.
Use HAND HOLDs to carefully unfold and fold the ramp.
Unless your transit agency has a published policy stating that driver/attendants do not aid ramp (disabled) passengers, it is the responsibility of the driver/attendant to ensure that ramp pas- sengers enter and exit the vehicle on the ramp in the safest manner.
safe transport of wheelchair passengers. Follow all safety instructions regarding torso restraints, stabil- ity, balance, weight distribution and use of atten- GDQWVDVVSHFLÀHGLQWKHRZQHUҋVPDQXDOVXSSOLHG with the passenger’s wheelchair (or other mobility aid). Wheelchair passengers must determine, establish and practice ramp boarding and exiting procedures under the direction of the their personal health care professional and wheelchair representa- tive. Those procedures should be conveyed to the ramp attendant. Know your passengers abilities and needs for optimum safety.
ADA requirements state that transit drivers/at- tendants must assist with attaching and removing wheelchair and occupant restraint belts.
Ramp passengers (wheelchair passengers and standees), and attendants must use common VHQVHDQGJRRGMXGJPHQWUHJDUGLQJUDPSVDIHW\ Each wheelchair passenger (or standee) has a unique set of physical abilities combined with the physical characteristics of his or her wheelchair (or other mobility aid) that dictate the method in which he or she will enter and exit the vehicle.
Attendants must never operate the vehicle, the ramp or assist passengers if intoxicated. Intoxi- cated passengers should not be allowed to board or exit the vehicle.
Passengers should be positioned in the center of the ramp at all times. Attendants and ramp pas- sengers must be able to clearly view the ramp whenever boarding and exiting the vehicle. The
Wheelchair attendants should be instructed on any special needs and/or procedures required for

W ARNING
W ARNING
Position and fasten the wheelchair- equipped occupant seat belt before loading onto the wheelchair ramp. Failure to do so may result in serious bodily injury and/or property damage.
Be aware of ramp slope.
Stabilizing Wheelchairs: Pow- ered and manual wheelchairs are designed to remain upright and stable during normal opera- tion. All activities which involve movement in a wheelchair have an effect on the combined center of gravity of the occupant and wheelchair. Be aware of the ramp slope (angle). The slope of the ramp has a direct effect on the center of gravity. The wheelchair passenger’s center of gravity and their ability to maintain stability and balance must be kept in mind by the wheelchair passenger and the attendant.
when on the ramp. Wheelchair passengers should not raise the front wheelchair wheels (pull wheelie) when on the ramp.
attendant and/or wheelchair pas- senger must ensure the ramp is fully deployed before exiting the vehicle. Observe your passen- gers at all times when they are entering and exiting the vehicle.
Wheelchair passengers who intend to enter and exit the vehicle without the assistance of an attendant must determine the safest and most practical method and orientation of entering and exiting based on the physical characteristics of their personal wheelchair and his or her physical capabilities to maintain stability while the wheelchair is in motion on the ramp.
Wheelchair-Equipped Occupant Seat Belts: Wheelchair passen- gers should position and buckle their wheelchair-equipped seat EHOW WRUVRUHVWUDLQW DVVSHFLÀHG by the manufacturer, before load- ing onto a wheelchair ramp.
The aid of an attendant stabilizing the wheelchair is recommended for optimum safety. Wheelchair passengers who are unable to maintain stability and balance should not board a ramp without assistance. Counterbalance devices (anti-tippers) may be available from the wheelchair rep- resentative to enhance stability and balance.
Wheelchair Attendants: When assisting a wheelchair occupant, remember to use good body me- chanics. When the wheelchair is on the ramp, the attendant must grasp the push handles (or other) securely. Detachable wheelchair parts such as arms or leg rests must never be used for hand holds or lifting supports. Doing so could result in the parts being inadvertently detached from the wheelchair resulting in possible injury to the wheelchair occu- pant and/or the attendant.
Different types of disabilities require different types of wheel- chairs and different types of wheelchair-equipped occupant restraint belt systems (torso re- straint). It is the responsibility of the wheelchair passenger to have his or her wheelchair equipped with an occupant restraint (seat belt) under the direction of their health care professional.
Wheelchairs should be operated at a slow and constant speed when on the ramp. Wheelchairs should not accelerate suddenly

SAFETY FIRST! Know That
All information contained in this manual and B W ARNING


supplements (if included), is pro- vided for your safety. Familiarity with proper operation instructions as well as proper maintenance procedures are necessary to en- sure safe, trouble free operation. Safety precautions are provided to identify potentially hazardous situations and provide instruction on how to avoid them.
This symbol indicates important safety information regarding a potentially hazard- ous situation that could result in serious bodily injury and/or property damage.
This symbol indicates important information regarding how to avoid a hazardous situation that could result in minor person- al injury or property damage.
These symbols will appear throughout this manual. Recognize the seriousness of this information.
WARNING Read this manual and supplement(s) before performing instal- lation, operation or service procedures.
If installation, main- tenance or repair procedures cannot be completed ex- actly as provided in this manual or if the instructions are not fully understood, contact The Braun Corporation immedi- ately. Failure to do so may result in serious bodily injury and/or property damage.
,QVWDOODWLRQVSHFLÀFDWLRQVDQGGLPHQVLRQVPXVWEHPHW
W ARNING
Remove any obstructions within the ramp mounting/operating area prior to beginning installation procedures.
Do not operate ramp prior to positive securement of the pan.
Check for obstructions such as gas lines, wires, exhaust, etc. before drilling or cutting during installation procedures.
Route all cables clear of exhaust system, other hot areas, moving parts, wet areas, etc.
5LVNRIHOHFWULFDOVKRFNRUÀUH8VHH[WUDFDUHZKHQPDNLQJ electrical connections. Connect and secure as outlined in Installation Instructions and Wiring Diagrams.
0HHWDOOUDPSSRVLWLRQLQJDQGFOHDUDQFHVSHFLÀFDWLRQVDVGHWDLOHGLQWKH3RVLWLRQLQJDQG Clearance Checklist before operating ramp.
Maintenance and repairs must be performed only by authorized service personnel.
Perform maintenance and lubrication procedures exactly as outlined in the Maintenance and Lubrication Schedule contained in this manual.

Installation/Service Safety Precautions (Continued)
Disconnect the power cable at the battery prior to servicing.
Keep hands, arms and all other body parts clear of moving parts.
Never modify (alter) a Braun Corporation ramp.
Replacement parts must be Braun authorized replacements.
Never install screws or fasteners (other than factory equipped).
Whenever replacing a hydraulic cylinder or seals, deploy ramp fully.
)DLOXUHWRIROORZWKHVHVDIHW\SUHFDXWLRQVPD\UHVXOWLQVHULRXVERGLO\LQMXU\DQGRUSURS- erty damage.
W ARNING
Braun RA300 Ramps must be installed and serviced by a Braun authorized service representa- tive who has attended and been FHUWLÀHGE\7KH%UDXQ&RUSRUD- tion Sales and Service School for Braun Mobility Products.
Read and become familiar with the operating instructions and the installation instructions contained in this manual before beginning installation, operation or service procedures.
Read this manual, before performing installation, operation or service procedures. Failure to do so may result in serious bodily injury and/or property damage.
The Braun RA300 Ramp is de- VLJQHGIRUXVHLQORZÁRRUWUDQVLW YHKLFOHV$´ÁRRUSRFNHWµ PRXQW- ing hole) built into the chassis/ ÁRRUV\VWHPDOORZVIRUVLPSOHLQ- stallation (accepts “drop-in” unit). The Floor Pocket Clear Open- ing DimensionsDUHVSHFLÀHGRQ pages 15 and 16. See Figures B, C, D and E.
SRFNHWµFRQÀJXUDWLRQ QRWVXS- plied).
ADA: Installations with the sup- port tube positioned higher than 12” above ground level may not comply with ADA ramp slope requirements.
Slope:7KHSRUWLRQRIWKHÁRRU where the ramp mounts must slope at an approximate 8° angle (see Figure C).
Some OEM chassis meet these VSHFLÀFDWLRQV7KH5$UDPS was designed to conform to these VSHFLÀFDWLRQV
Outboard Support Tube: An outboard support tube must be positioned under the outboard edge of the opening (minimum 1-1/2” x 2” steel tube). See Fig- ures C and D. The recommended height of the support tube is 12” above ground level. Kneeling Vehicles: This dimension mea- sured with suspension lowered.
The ramp installer must provide an appropriate framework in the applicable location in the vehicle (aligned center with passenger door opening). Ramp assembly mounting hardware and/or brack- ets are directly dependant upon WKHYHKLFOHFKDVVLVDQG´ÁRRU
The ramp pan horizontal bor- GHU OLS VHWVRQWKHÁRRUSRFNHW SHULPHWHU IUDPHZRUNVXEÁRRU HWF 7KHÀQLVKHGÁRRULQJFDQEH cut to conform to the border of the SDQIRUDÁXVKWUDQVLWLRQVXUIDFH IURPUDPSWRÁRRU

Door Opening: Open the door(s) fully and check the clear door opening width dimension. Speci- ÀHGPLQLPXPFOHDUGRRURSHQ- ing width must be provided (34" for 32" ramps and 39-1/2" for 37" ramps). See Figure F.
Minimum Clear Door Opening 'LPHQVLRQVDUHGHÀQHGDVÀQ- ished door opening, including any LQWUXVLYHGRRUMDPEVKHDGHUV sills or hinges.
should be removed. The molding FDQEHPRGLÀHGWRÀWDURXQGWKH ramp pan horizontal border (lip).
There must be a minimum 1/8” clearance between the de- ployed ramp assembly and the YHKLFOHÁRRURUDQ\REVWUXFWLRQ RQWKHÁRRU VXFKDVDUXEEHUVLOO or threshold).
Obstructions: Any intrusive ob- structions within the door opening or the ramp mounting/operating area (such as seats, molding, lights, brackets, etc.) must be re- moved. Trim or molding that cre- ates an uneven mounting surface
Door(s) must open outward. When closed, the door(s) should align with and conform to the outboard edge of the ramp pan (rubber seal on bottom of door).
Outboard Support Tube: Recom- mended Height: 12” above ground level. Kneeling Vehicles (measured with suspension lowered).
ADA: Installations with support tube positioned higher than 12” above ground level may not comply with ADA ramp slope requirements.
7KHSRUWLRQRIWKHÁRRUZKHUHWKH ramp mounts must slope at an ap- proximate 8° angle.
Figure C



Figure D Structure: Minimum 1-1/2” x 2” steel tub- ing (or equivalent).
Outboard Support Tube


34-3/4" for 32" Ramp 39-3/4" for 37" Ramp
As viewed from outside the vehicle

34" for 32" Ramp 39-1/2" for 37" Ramp
9HKLFOHFKDVVLV´ÁRRU SRFNHWµFRQÀJXUDWLRQ must be aligned cen- ter with door opening.



There must be a minimum 1/8” clearance between the deployed ramp assembly and WKHYHKLFOHÁRRURUDQ\REVWUXFWLRQ on the ÁRRU VXFKDVDUXEEHUVLOORUWKUHVKROG

An 8-pin Deutsch connector is mounted at the back of the RA300 ramp. A mating connector (male plug) is supplied with the ramp. The power supply (12 volt or 24 volt), the ground, a ramp OUT signal (+) and a ramp IN sig- nal (+) must be terminated in the supplied Deutsch connector.
ramp control switch (center off) will typically be mounted near the driver. The control switch may be part of a panel providing other features and controls (power on/ off indicators, LED’s, etc.).
Route cables clear of exhaust system, other hot areas and moving parts. Failure to do so may result in serious bodily injury and/or property damage.
Make electrical connections as shown in Figure K page 19. Strip wires, crimp and install contacts DVVSHFLÀHGLQLQVWUXFWLRQVVXS- plied with 8-pin Deutsch connec- tor.
The ramp installer provides an appropriate control switch for the end user. A momentary contact
The Positive (+) “battery” lead wire must be protected by an in-line 30 ampere fuse or circuit breaker (installer pro- vided).
Secure all cables using cable ties and/or cable clips (mount clips with self-tap screws).
Do not connect the power “battery” lead wire to the battery until all other connec- tions are made.
Connect the 8-pin Deutsch male plug to the mating Deutsch connector mounted at the back of the pan.
Carefully connect the power “battery” lead wire to the Positive (+) battery post.
Chassis Ground Corrosion: When mounting chassis ground cables, remove undercoating, dirt, rust, etc. from the framing member around the mounting holes. Apply a protective coating to mounting holes to prevent corrosion. Apply grease to ground cable terminals and mounting hardware. Failure to do so will void warranty of certain electrical components.
Risk of electrical shock! Use extra care when making electrical connec- tions.
5LVNRIHOHFWULFDOÀUH Use extra care when making electrical connections.

An 8-pin Deutsch connector (male plug) is supplied with the ramp.
Terminate the power supply, ground, ramp OUT signal and ramp IN signal DVVSHFLÀHGLQOHJHQG
The ramp installer provides an ap- propriate momentary contact control switch.
Positive (+) battery lead wire must be protected by installer-provided 30 ampere fuse or circuit breaker. Failure to do so may result in serious bodily injury and/or property damage.
The Positive (+) “battery” lead wire must be protected by an in-line 30 ampere fuse or circuit breaker (installer provided).
TO USER CONTROL SIGNAL TO DEPLOY RAMP - (MOMENTARY SWITCH)
TO USER CONTROL SIGNAL IGNITION/MANUAL RELEASE - BF3248YP ONLY
TO POWER SOURCE - (30 AMP. CURCUIT PROTECTION DEVICE)
TO USER CONTROL SIGNAL TO STOW RAMP
CONNECTOR - P1
BF3248YP CONNECTOR - P1
(B.C.# 30136)
(B.C.# 30136)
E
D
TO SIGNAL TO RAMP STOW INDICATOR
TO SIGNAL TO RAMP DEPLOY INDICATOR
A
B
F
G
H
E
D
A
B
F
G
H
WIRING PROVIDED
TO VEHICLE GROUND
BY INSTALLER
OR
WIRING PROVIDED
BY INSTALLER
8-COND WIRE CODE
PIN
COLOR
8-COND WIRE CODE
A
POWER SOURCE - 12 GA.*
PIN
COLOR
B
VEHICLE GROUND - 12 GA.*
A
POWER SOURCE - 12 GA.*
TO USER STOW - 16 GA.*
B
VEHICLE GROUND - 12 GA.*
D
TO USER DEPLOY - 16 GA.*
TO USER STOW - 16 GA.*
E
PLUG - NOT USED
D
TO USER DEPLOY - 16 GA.*
F
PLUG - NOT USED
E
PLUG - NOT USED
G
RAMP STOW SIGNAL - 16 GA.*
F
H
RAMP DEPLOY SIGNAL - 16 GA.*
USER IGN/MAN REL. - 16 GA.*
* RECOMMENDED WIRE GAUGE
G
RAMP STOW SIGNAL - 16 GA.*
H
RAMP DEPLOY SIGNAL - 16GA.*

8-pin Deutsch Male Plug (supplied with ramp)
8-pin Deutsch Connector (ramp equipped)
Electrical Connections · Electrical Connections Illustration

See the Maintenance/Lubrication Schedule for recommended applications per number of cycles or elapsed time.
Gear and Gear Rack
LO
LO
LO
Drive Arm and Cam Gear Shaft
(after Smooths or 1200 Cycles)
LO
DE
6SHFLÀHG UHFRPPHQGHG $YDLODEOH %UDXQ Lubricant Type Lubricant Amount Part No.
Light Penetrating Oil LPS2, General Purpose 11 oz. (30 weight or equivalent) Penetrating Oil Aerosol Can
LO - Light Oil
Stainless Stick Door-Ease 1.68 oz. Style (tube) Stick (tube)
Light Grease Lubricate 14 oz. (Multipurpose) Can LG - Light Grease

Maintenance and Lubrication Introduction
Proper maintenance is necessary to ensure safe, trouble-free operation. Inspecting the ramp for any wear, damage or other abnormal conditions should be a part of all transit agencies daily service program (preventive maintenance). Simple inspec- tions can detect potential problems.
WARNING cedures and will vary according to ramp use and conditions. Transit agencies operating vehicles equipped with ramps that are not monitored by cycles may choose to have the ramp system main- tained on the same schedule as the vehicle (routine maintenance). Doing so ensures the ramp is being main- tained regularly. When servicing the ramp at the consecutive recom- mended intervals, inspection and lubrication proce- GXUHVVSHFLÀHGLQWKHSUHYLRXVVHFWLRQVVKRXOGEH performed (repeated). All listed inspection, lubrication and maintenance procedures should be repeated at “8 Weeks or 200 Cycles” intervals following the scheduled “1 Year or 1250 Cycles” maintenance.
Maintenance and lu- brication procedures must be performed DVVSHFLÀHGE\DQ authorized service technician. Failure to do so may result in serious bodily injury and/or property damage.
A generic Daily Preventive Maintenance Sched- ule is provided in this manual for transit agency use. The form can be tailored to your particular application. Preventive maintenance visual inspec- tions do not take the place of the procedures speci- ÀHGLQWKLVVFKHGXOH
The maintenance and lubrication procedures speci- ÀHGLQWKLVVFKHGXOHmust be performed by a Braun authorized service representative at the scheduled intervals according to the number of cycles or HODSVHGWLPHZKLFKHYHUFRPHVÀUVW
RA300 Ramps are equipped with hardened pins and self-lubricating bearings to decrease wear, provide smooth operation and extend the service life of the ramp.
Lifts exposed to severe conditions (weather, environ- ment, contamination, heavy usage, etc.) may require inspection and maintenance procedures to be per- IRUPHGPRUHRIWHQWKDQVSHFLÀHG
Clean the components and the surrounding area before applying lubricants. LPS2 General Pur- pose Penetrating Oil is recommended where Light Oil is called out. Use of improper lubricants can attract dirt or other contaminants which could result in wear or damage to the components. Ramp com- ponents exposed to contaminants when lowered to WKHJURXQGPD\UHTXLUHH[WUDDWWHQWLRQ6SHFLÀHG lubricants are available from The Braun Corporation (part numbers provided on page 20).
Discontinue ramp use immediately if maintenance and lubrication procedures are not properly performed, or if there is any sign of wear, damage or improper operation. Contact your sales representative or call The Braun Corporation at 1-800-THE LIFT®. One of our national Product Support representatives will direct you to an authorized service technician who will inspect your ramp.
Maintenance and Lubrication Schedule
Clean and lubricate. Apply Light Oil - See Lubrication Diagram
Clean and lubricate. Apply Light Oil - See Lubrication Diagram
Drive arm pivot pins (screws, nuts and bearings)
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram continued
Drive arm and cam gear pivot shaft
Inboard ramp hinge · Outboard ramp hinge

Cable at pulley and hinge areas
Clean and lubricate. Apply Light Oil - See Lubrication Diagram
Apply Door-Ease. See Lubrication Diagram
Inspect drive arm pivot points (mounting screws, nuts and bearings) for positive secure- ment, wear or damage
Tighten, replace or correct as needed.
Cycles
Inspect drive arm slots for excessive wear or damage
Clean ramp and ramp mounting area (ensure no debris in area to obstruct stowing/stacking)
Clean and remove debris or obstructions
Cycle ramp and observe drift speed during deploy and stow functions
,IGULIWVWRRIDVWDGMXVWDSSOLFDEOH'ULIW0LFUR- switch Cam so drift begins at reduced height.
Inspect ramp for wear, damage or any abnor- mal condition.
Perform all procedures listed in previous section also
5HPRYHVXEÁRRU SDQFRYHU DQGFOHDQGLUW and other foreign debris
Blow out with air compressor
5HPRYHVXEÁRRU SDQFRYHU DQGOXEULFDWH drive arm gear and cylinder gear rack
Clean and lubricate. Apply Door-Ease
5HVHFXUHDGMXVWPLFURVZLWFKHVUHSODFHGDP- aged parts or otherwise correct as needed.
nections for wear, damage or leaks

Hydraulic Fluid (Pump) - Check level. Note: Fluid should be changed if there is visible contamination. Inspect the hydraulic system F\OLQGHUKRVHVÀWWLQJVVHDOVHWF IRUOHDNVLI ÁXLGOHYHOLVORZ
Use Braun 32840-QT (Exxon® Univis HVI 26) K\GUDXOLFÁXLG do not mix with Dextron III or RWKHUK\GUDXOLFÁXLGV &KHFNÁXLGOHYHOZLWK ramp deployed fully. Fill to within µRIWKHERWWRPRIWKHµÀOOWXEH QHFN
Inspect vehicle-to-ramp wiring harness
Resecure, repair or replace or otherwise correct as needed
Check to see that the ramp is securely an- chored to the vehicle and there are no loose bolts, broken welds, or stress fractures.
Replace decals if worn, missing or illegible. Replace antiskid if worn or missing.
Repeat all previously listed inspection, lubrica- tion and maintenance procedures at 8 week or 200 cycle intervals (or per vehicle maintenance schedule).
continued · Mounting · Decals and Antiskid

Microswitches: Three micro- switches (limit switches) are incorporated in the RA300 Ramp electrical system. "Y" ramp mod- els microswitches are: Drift-In, Drift-Out and Counter. The "YP" ramp model also has three micro- switches: Drift-In, Drift-Out and
Power Down Activation. Details and photos of the microswitches DUHSURYLGHGEHORZ$GMXVW microswitch(es) as detailed (if necessary only).
Improper microswitch adjustment may re- sult in serious bodily injury and/or property damage.
Stowed Position: When the ramp is in the stowed posi- tion, the Drift-Out and Counter microswitches are deactivated (common and normally closed terminals have continuity). In contrast, the Drift-In microswitch is activated.
downward to ground level, during which, at some position, the Drift- Out microswitch is activated. The Drift-In microswitch is deactivated during the deploy movement of the platform. Note, however, that neither of the other 2 micro- switches have any bearing on the deploy sequence.
When the ramp’s platform reach- es the Drift-Out limit (approx. 45° above ground level) and deacti- vates the microswitch, the current to the Stow Relay will be inter- rupted.
"Y" Models Only: When the ramp’s platform reaches the Drift-In limit (approx. 15° above YHKLFOHÁRRUOHYHO WKHPLFUR- switch is activated and the current to the Stow Relay is interrupted thus stopping the current to the pump motor. The platform then “drifts” downward to the vehicle ÁRRU7KH'ULIW2XWPLFURVZLWFKLV also deactivated during the stow movement of the platform
Deploy Sequence: When the ramp is in the stowed position, the Drift-Out microswitch is deacti- vated. Current is allowed to pass from the vehicle Deploy Relay, which directs current to the Bidi- rectional Pump motor in direction A (hydraulically drives cylinders to deploy ramp).
Deployed Position: When the ramp is in the deployed posi- tion, the Drift-Out and Counter microswitches are activated. In contrast, the Drift-In microswitch is deactivated.
Stow Sequence: When the ramp is in the deployed posi- tion, the Drift-In microswitch is deactivated, allowing current to pass from the vehicle Stow switch circuit and energize the ramp Stow Relay, which directs current to the Bidirectional Pump motor in direction B (hydraulically drives cylinder to stow ramp).
When the ramp’s platform reach- es the Drift-In limit (approx. 45° above ground level), the micro- switch is activated (common and normally open terminals have continuity), and the current to the Deploy Relay is interrupted thus stopping the current to the pump motor. The platform then “drifts”
Electrical

Drift In Microswitch (Cam 1 - All RA300 Models)

Turn Cam #1 counter-clockwise to start Drift In function sooner (shut pump off).
Turn Cam #1 clockwise to start Drift In function later (allow ramp to stow further before pump shuts off).

Drift Out Microswitch (Cam 2 - All RA300 Models)
Turn Cam #2 clockwise to start Drift Out function sooner (shut pump off).
Turn Cam #2 counter-clockwise to start Drift Out function later (allow ramp to deploy further before pump shuts off).

Turn Cam #3 clockwise to start Interlock sooner.
Turn Cam #3 counterclockwise to return Interlock signal later.
1 2 3 Power Down Microswitch (Cam 3 - "YP" Models Only)
Turn Cam #3 clockwise to begin power down sooner.
Turn Cam #3 counterclockwise to delay power down.
Electrical (Continued)

M-2202-0102 Hydraulic Pump: Fixed displacement external gear type hydraulic pump with 12 VDC electric motor and 76 cubic inch ÁXLGUHVHUYRLUIRU9%)< and 12V BF3748Y. The Braun Pump Code for 12 volt M-2202- 0102 pumps is 59.
B-3202-0100 Hydraulic Pump: Fixed displacement external gear type hydraulic pump with 12 VDC electric motor and 76 cubic inch ÁXLGUHVHUYRLUIRU9%)
'H[WURQ,,,RURWKHUK\GUDXOLFÁX- ids. Make sure the ramp is fully deployedZKHQFKHFNLQJÁXLG OHYHORUDGGLQJÁXLG)LOOWRZLWKLQ 1" of the top of the reservoir. DO NOT XVHDVROLGSOXJRUÀOOFDS without a breather hole. Doing so will result in pump and/or reser- voir damage.
All RA300 Hydraulic Pumps: The Deploy pressure relief valve is factory set at 1000 psi. The Stow pressure relief valve is fac- tory set at 1250 psi.
M-2202-0102 Hydraulic Pump: Fixed displacement external gear type hydraulic pump with 24 VDC electric motor and 76 cubic inch ÁXLGUHVHUYRLUIRU9%)< and 24V BF3748Y. The Braun Pump Code for 24 volt M-2202- 0102 pumps is 60.
Contamination: Fluid should be changed if there is visible con- tamination. Inspect the hydraulic V\VWHP F\OLQGHUKRVHVÀWWLQJV VHDOVHWF IRUOHDNVLIÁXLGOHYHO is low.
7KHVHDGMXVWPHQWVRQWKHSXPSXQLWOLPLWWKHPD[LPXPRLOSUHVVXUHLQWKH system to a safe level. It also keeps the amp draw and battery drain at a minimum when the cylinders reach full stroke.
Contact The Braun Corporation before adjusting hydraulic pressure relief valve. Failure to do so may result in serious bodily injury and/or property damage.
The Deploy pressure relief valve is preset at 1000 psi. The Stow pressure relief valve is preset at 1250 psi. Do not WDPSHUZLWKWKLVDGMXVWPHQWXQOHVV absolutely necessary (will not stow or deploy ramp) and then, only after contacting The Braun Corporation. Note:7KHÀ[HGQXWRQHDFKDGMXVWPHQW Allen screw is positioned to limit oil pressure to a maximum (Deploy relief valve maximum 1450 psi and Stow relief valve maximum 1700 psi). Do not DWWHPSWWRORRVHQRUUHPRYHWKHRXWHUÀ[HGQXW
Relief Valve Access:7KHUDPSSDQFRYHU VXEÁRRU PXVWEHUHPRYHGWR access the relief valve (access hole not provided).

Relief Valve Hex Jamb Nut

RA300 ramp models featuring gravity down deploy DQGVWRZGULIWDUHHTXLSSHGZLWKDGMXVWPHQWFDPV %)

Drift out cam controls the speed that the ramp moves when the ramp is almost fully deployed and the motor shuts off.

Drift in cam controls the speed that the ramp moves when the ramp is almost fully stowed and the motor shuts off.

Clockwise · Counter-Clockwise

If a problem occurs with your ramp, discontinue operation immediately! Contact your sales representative or call The Braun Corporation at 1-800-THE LIFT®. One of our national Product Sup- port representatives will direct you to an authorized service techni- cian who will inspect your ramp.
&KDUW7KHVSHFLÀFFDXVHDQG remedy can then be determined by process of elimination. Wiring Diagrams, Electrical Schematics, Hydraulic Diagrams and Hydrau- lic Schematics are provided to aid in troubleshooting.
Troubleshooting and repair procedures must be performed DVVSHFLÀHGE\DQ authorized service technician only. Failure to do so may result in serious bodily injury and/or property damage.
A Repair Parts section with an exploded view and corresponding parts list is also provided. Correct the problem if possible. If the problem continues, contact The Braun Corporation.
The cause of the problem can be determined by locating the lift function and related symptom in the Troubleshooting Diagnosis
1.11 Battery terminals dirty 1.12 Chassis ground connection (frame ground cables) 1.13 Battery damaged 1.14 Battery discharged 1.15 25 ampere in-line fuse faulty 1.16 Power cable 1.17 Vehicle Interlock(s) circuit incomplete 1.18 Vehicle-to-ramp wiring harness
Clean and tighten Clean and tighten. See Chassis Ground Corrosion on page 18. Replace Charge battery Replace fuse Check for loose terminals or broken wire Correct or replace Disconnect harness from ramp. Using volt meter, test (probe) 8-pin Deutsch male plug terminals as follows: Pin A = +12/24 V Pin B = -Ground Pin C = V (when Stow switch is activated) Pin D = V (when Deploy switch is acti- vated)
1.10 No Power
To Ramp (Circuit Problem)
1.21 Ramp wiring harness
Remove relays from sockets. Using volt meter, test (probe) wires/terminals at relay sockets: Red = +12/24 V Black = -Ground Blue = V (when Stow switch is activated) Orange = V (when Deploy switch is activated) Replace Clean and tighten Repair Crimp tightly to wire
1.20 Power to Ramp But
1.22 Faulty relay(s) 1.22 Loose connection(s) 1.24 Broken wire(s) 1.25 Wire terminal(s)
2.11 See 1.00 'ULIW2XW0LFURVZLWFKRXWRIDGMXVW-
See Microswitches in Systems Descrip- tions for details Connect, repair or replace
2.10 No Operation
ment or damaged 2.13 Drift Out Microswitch harness dis- connected, damaged or otherwise damaged 2.14 Pump motor brushes worn
Contact Braun Product Support - replace pump
No Pump Operation · continued continued

2.20 Locked in Intermediate
2.21 Ramp was stopped within the Deploy “Drift Out” range during Stow function
Activate Stow function until ramp is out of the Deploy “Drift Out” range. Then activate Deploy function.
Position (No Response to Deploy Switch/No
2.31 Physical obstruction (20 lb or more) on ramp 2.32 Mechanical binding 2.33 Deploy pressure relief valve setting too low /RZK\GUDXOLFÁXLGVXSSO\Note:
Check and correct $GMXVWUHOLHIYDOYHVHWWLQJ6HH6\VWHPV Descriptions for details. Use Braun 32840-QT (Exxon® Univis HVI K\GUDXOLFÁXLG do not mix with Dex- WURQ,,,RURWKHUK\GUDXOLFÁXLGV &KHFN oil level with ramp fully deployed. See Systems Descriptions for details. Repair Replace. Contact Braun Product Support - replace pump
2.30 Pump Runs
Fluid should be changed if there is visible contamination. Inspect the K\GUDXOLFV\VWHPIRUOHDNVLIÁXLG level is low. 2.35 Leak in hydraulic system 2.36 Cylinder leak 2.37 Deploy pressure relief valve stuck open due to contamination or other- wise damaged 2.38 Pump internal shuttle valve stuck or damaged
Contact Braun Product Support - replace pump
Lubricate pivot pins. See Maintenance and Lubrication Schedule and Diagram Correct/Replace/Lubricate. See Main- tenance and Lubrication Schedule and Diagram
2.40 Faulty or
Check and correct Check for contamination or kinks - correct or replace Thin with Diesel fuel - 2 T. Change in spring. See Systems Descriptions for full- WLPHFROGFOLPDWHVSHFLÀFDWLRQV
2.50 Drifts Excessively
2.51 See 2.38 and 2.40 3XPSLQWHUQDORULÀFHSOXJJHGRU
Contact Braun Product Support - replace pump 6HHGULIWFDPDGMXVWPHQWSURFHGXUH
Slow (or No Drift)
2.60 Drifts Excessively
2.61 See 2.35 and 2.36 3XPSLQWHUQDORULÀFHHQODUJHGRU
Contact Braun Product Support - replace pump 6HHGULIWFDPDGMXVWPHQWSURFHGXUH

3.11 See 1.00 'ULIW,Q0LFURVZLWFKRXWRIDGMXVW-
3.10 No Operation
$GMXVWRUUHSODFH6HH0LFURVZLWFKHVLQ Systems Descriptions for details Connect, repair or replace
ment or damaged 3.13 Drift In Microswitch harness discon- nected, damaged or otherwise damaged
3.20 Locked in Intermediate
3.21 Ramp was stopped within the Stow “Drift In” range during Deploy func- tion ("Y" models only)
Activate Deploy function until ramp is out of the Stow “Drift In” range. Then activate Stow function.
Position (No Response to
3.41 See 2.31, 2.32, 2.34, 2.35 and 2.36 3.42 Stow pressure relief valve setting too low 3.43 Stow pressure relief valve stuck open due to contamination or other- wise damaged
3.40 Pump Runs
$GMXVWUHOLHIYDOYHVHWWLQJ6HH6\VWHPV Descriptions for details. Contact Braun Product Support - re- place pump
(In)
3.50 Faulty or
4.51 See 2.40
3.60 Drifts Excessively
4.61 See 2.40 and 2.50
Slow (or No Drift)
4.71 See 2.35, 2.36 and 2.62
3.70 Drifts Excessively


Electrical Schematic - BF3248Y & BF3748Y
POWER CONNECTIONS / CONTROL SIGNALS (PROVIDED BY INSTALLER) SYMBOL KEY

12 GA. BK 16 GA. BL/BK 16 GA. BN/BK
12 GA. BK 16 GA. OR/BK 16 GA. OR/BK



Electrical Schematic - BF3248YP
POWER CONNECTIONS / CONTROL SIGNALS (PROVIDED BY INSTALLER) SYMBOL KEY

RD - 12 GA. 12 GA. or 14 GA. *

Wiring Diagram - BF3248YP

USER IGN. / MAN. REL. - 12 or 14 GA.*
WHITE - 14 GA. & WHITE - 14 GA.
BL/BK - 14 GA. & BL/BK - 14 GA.

Hydraulic Schematic - BF3248Y & BF3748Y


Hydraulic Diagram and Parts List - BF3248Y and BF3748Y
Item Qty. Description BF3248Y BF3748Y
1 1 Cylinder - 1514.3 - Compact C1514.3-9800 C1514.3-9800 2 1 Cylinder - 1514.3 - Compact C1514.3-9900 C1514.3-9900 3 1 Pump - Power Unit - Hydraulic - RA300 31698-12V or 24V* 31698-12V or 24V* 4 1 Hose Assembly - 6" - 1/8" Dia - SW/SW 16004A-006 - 5 2 Hose Assembly - 10" - 1/8" Dia - SW/SW 16004A-010 - 6 3 Hose Assembly - 12" - 1/8" Dia - SW/SW 16004A-012 - 7 2 Hose Assembly - 12" - 1/8" Dia - SW/SW - 16004A-012 8 4 Hose Assembly - 16" - 1/8" Dia - SW/SW - 16004A-016 9 2 Hose Assembly - 28" - 1/8" Dia - SW/SW 16004A-028 - 10 2 Hose Assembly - 36" - 1/8" Dia - SW/SW - 16004A-036 11 6 Elbow - 45* - 7/16-20 + 7/16-20 SAE Male O-Ring 24505 24505 12 2 Tee - 7/16 O-Ring RUN - 7/16 M. JIC37* 24505 24505 13 5 Elbow - 7/16-20 M/O-Ring/37* 25085 25085 14 1 Fitting - 7 /16-20 - 7/16-20 - 37* 24504 24504 * Optional 24V Model Ramp

5 or 7

Hydraulic Schematic - BF3248YP


Hydraulic Diagram and Parts List - BF3248YP
Item Qty. Description BF3248YP
1 1 Cylinder - 1514.3 - Compact C1514.3-9800 2 1 Cylinder - 1514.3 - Compact C1514.3-9900 3 1 Pump - Power Unit - 12V Hydraulic - RA300 33364 4 1 Switch - Pressure 31199 5 1 Hose Assembly - 8" - 1/8" Dia - SW/SW 16004A-008 6 1 Hose Assembly - 10" - 1/8" Dia - SW/SW 16004A-010 7 1 Hose Assembly - 12" - 1/8" Dia - SW/SW 16004A-012 8 1 Hose Assembly - 16" - 1/8" Dia - SW/SW 16004A-016 9 1 Hose Assembly - 20" - 1/8" Dia - SW/SW 16004A-020 10 1 Hose Assembly - 22" - 1/8" Dia - SW/SW 16004A-022 11 1 Hose Assembly - 26" - 1/8" Dia - SW/SW 16004A-026 12 11 Elbow - 45* - 7/16-20 + 7/16-20 SAE Male O-Ring 24505 13 2 Elbow - 7/16-20 M/O-Ring/37* 25085 14 1 Fitting - 7 /16-20 - 7/16-20 - 37* 24504


Item Qty. Description BF3248Y BF3748Y BF3248YP
1 1 Pan - Weldment BF00267WY BF37304WY BF00267WY 2 1 Drive Arm - Left - Weldment BF00261LWBKN BF00261LWBKN BF00261LWBKN 3 1 Drive Arm - Right - Weldment BF00261RWBKN BF00261RWBKN BF00261RWBKN 4 2 Gear Rack - Weldment RA40402WBKN RA40402WBKN RA40402WBKN 5 2 Bearing Strip RA40105 RA40105 RA40105 6 4 Bearing - Flange - 3/4" x 1/4" - 12FDU04 24012 24012 24012 7 2 Pin - Cylinder Mount BF00067 BF00067 BF00067 8 2 Pin - Cylinder / Rack RA40002 RA40002 RA40002 9 1 Cylinder - 1514.3 - Compact C1514.3-9800 C1514.3-9800 C1514.3-9800 10 1 Cylinder - 1514.3 - Compact C1514.3-9900 C1514.3-9900 C1514.3-9900 11 2 Shaft - Main Pivot BF00239 BF00239 BF00239 12 2 Nut - 1/4-20 Nylock - Auto Black 14614 14614 14614 13 2 Bolt - 1/4-20 x 2 1/2" Hex 10004 10004 10004 14 2 Washer - Shaft Main Pivot BF00248 BF00248 BF00248 15 2 Bolt - 5/16-18 x 1/2" 316 SS Hex BF00251 BF00251 BF00251 16 2 Washer - Spherical SS 5/8" OD - 2pcs BF00229 BF00229 BF00229 17 1 Drive Arm BF00215LBKN BF00215LBKN BF00215LBKN 18 1 Drive Arm BF00215RBKN BF00215RBKN BF00215RBKN 19 4 Shaft - Sheave BF00238 BF00238 BF00238 20 2 Shaft - Bearing Support BF37317 BF37317 BF37317 21 2 Bearing - 5/16" ID - 3/8" OD - 1/2" L 31902 31902 31902 22 4 Spacer - Drive Arm BF00240 BF00240 BF00240 23 2 Bearing - Ramp Fold BF00221 BF00221 BF00221 24 8 E-Clip - 3/8" Shaft 84383 84383 84383 25 1 Ramp Platform - Stage 1 BF00200Y BF37401Y BF00200Y 26 1 Ramp Platform - Stage 2 BF00201Y BF37402Y BF00201Y 27 1 Plate - Transition BF00247Y BF37406Y BF00247Y 28 1 Hinge - 2" x __" - SS with PEM Nuts - 1 Row 29960PS-1Y BF37403-1Y 29960PS-1Y 29 1 Hinge - 2" x __" - SS with PEM Nuts - 2 Rows 29960PS-2Y BF37403-2Y 29960PS-2Y 30 1 Plate - Hinge Support BF00013Y BF37307Y BF00013Y 31 6 Nut - Weld 10-32 x 9/32" Plain Slab Base 30209 30209 30209 32 2 Plate - Cable Retainer BF00235LY BF00235LY BF00235LY 33 2 Plate - Cable Retainer BF00235RY BF00235RY BF00235RY 34 2 Plate - Cable Retainer BF00236LBKN BF37404LBKN BF00236LBKN 35 2 Plate - Cable Retainer BF00236RBKN BF37404RBKN BF00236RBKN 36 2 Cable Retainer BF00237LY BF00237LY BF00237LY 37 2 Cable Retainer BF00237RY BF00237RY BF00237RY 38 8 Nut - #10-32 x 0.20 - Cable Retainer BF00242 BF00242 BF00242 39 10 Nut - #10-32 x 0.49 - Cable Retainer BF00243 BF00243 BF00243 40 1 Pump - Power Unit - __V Hydraulic - RA300 31698-12V or 24V** 31698-12V or 24V** 33364 41 2 Bolt - 3/8-16 x 1/2" 316SS Hex BF00249 BF00249 BF00249 42 1 Plate - Tapped #4-40 Microswitch 24998 24998 24998 43 92 Screw - #10-32 x 3/8 FL HD-HX SKT - Auto Black 24537 24537 24537 44 3 Microswitch - Sealed 30205 30205 30205 &DP0LFURVZLWFK$GMXVW%L)ROG %) %) %) &DP0LFURVZLWFK$GMXVW 5$ 5$ 5$ 47 2 Cam - Manual Valve - RA400/02 RA40500 RA40500 RA40500 48 3 Screw - #10-32 x 5/16" Set - Auto Black 11562 11562 11562 49 2 Screw - 1/4-28 x 3/8" Set 11566 11566 11566 50 2 Screw - #4-40 x 1 1/2" RD HD 11485 11485 11485 51 2 Relay - 30/40A SPDT 12V P&B Plastc. - Plug In 18087 18087 18087 52 1 Cycle Counter - LCD without Reset 30547 30547 30547 53 1 Nut - Panel - DT 114020-90 30030 30030 30030 54 1 Washer - Lock - DT 114021 30031 30031 30031 55 2 Cable 3/16" Nylon Coated 1/8" Cable/84" BF00252A BF37410A BF00252A 56 2 Nut - 1/4-28 SS Hex BF00250 BF00250 BF00250 57 12 Sheave - 3/16" Rope Dia. - Zinc/Bronze Bearing BF00254 BF00254 BF00254 58 2 Gas Spring - 7.87" M8 x 1.25 Threaded - 25 LB BF00255 BF00255 BF00255 59 2 Ring - 3/8" Retaining Snap 13889 13889 13889 60 2 Mount - Gas Spring BF00231BK BF00231BK BF00231BK 61 2 Mount - Sheave - Gas Spring BF00245BK BF00245BK BF00245BK 62 2 Pin - Gas Spring Sheave BF00246 BF00246 BF00246 63 10 Ring -1/2" Ext Snap - Auto Black 20946 20946 20946 64 26 Screw - #10-32 x 1/2 BHSCS - Auto Black 30375 30375 30375 65 2 Nylon Loop - Manual Backup RA40507 RA40507 RA40507 66 2 Washer - #10 Flat - Auto Black 11541 11541 11541 67 2 Nut - #10-32 with Lock Washer - Auto Black 18349 18349 18349 68 2 Foot - Rubber Adh Back 13/16" Sq. - Black 15759 15759 15759 69 1 Pan - Top RA300 BF00269Y BF37411Y BF00269Y 70 2 Antiskid Tape - __" x 21" 30081 BF37407 30081 71 2 Antiskid Tape - __" x 2.25" 30082 BF37408 30082 72 1 Antiskid Tape - __" x 22" - Red Braun Logo 30084 BF37409 30084 73 2 Tag - Serial# / Series# - Plastic 18548P 18548P 18548P 74 2 Decal - Danger Keep Clear 81819 81819 81819 75 1 Harness - Main Assembly BF00080A BF00080A BF00081A * Item not shown ** Optional 24V Model Ramp
*

Page 41A Page 42A



Page 41B Page 42B

BF3248Y = 36.97" BF3248YP = 36.97" BF3748Y = 41.98"
BF3248Y = 34.75" BF3248YP = 34.75" BF3748Y = 39.76"
BF3248Y = 32.07" BF3248YP = 32.07" BF3748Y = 37.02"
Inputs Required: +12 Volt Supply (-) Ground Ramp “Out” Signal (+) Ramp “In” Signal (+) Interlock Signal
BF3248Y = 2.56" BF3248YP = 2.56" BF3748Y = 2.72"
BF3248Y = 27.69" BF3248YP = 27.69" BF3748Y = 27.73"
BF3248Y = 10.96" BF3248YP = 1096" BF3748Y = 11.25"

BF3248Y = 33.53" BF3248YP = 33.53" BF3748Y = 38.48"
BF3248Y = 32.07" BF3248YP = 32.07" BF3748Y = 37.02"
BF3248Y = 36.77" BF3248YP = 36.77" BF3748Y = 41.98"
BF3248Y = 2.56" BF3248YP = 2.56" BF3748Y = 2.72"
23.18"
BF3248Y = 6.90" BF3248YP = 6.90" BF3748Y = 7.41"
8.4o

Vehicle Number:
Date:
Inspector:
Before each scheduled day of lift service, operate ramp minimum one complete cycle and inspect each of the following :
Do the vehicle interlock(s) function as intended?
Does the ramp deploy when the ramp interlock is activated as intended?
Does the lift control switch function properly?
Does the ramp cargo door light (if equipped) function as intended?
Do the lift cargo door securement devices function as intended (if equipped)?
Does the ramp safely clear the cargo door as the ramp is deployed and stowed?
Does the ramp operate at normal speed?
Is the lift power source adequate?
Do the drive arms clear the ramp and housing?
Is ramp operation quiet (no rattles, abnormal sounds, etc.)?
Are the ramp-posted decals worn, missing or illegible?
Is the ramp antiskid in place, worn or damaged?
Can you visually detect any ramp wear, damage, misalignment, hydraulic leaks, loose bolts, broken welds or any abnormal conditions?
Operate ramp minimum one complete cycle and check each of the above daily pre-trip inspec- tions if applicable for your daily inspection routine (outlined by your transit agency).
Clean ramp surfaces where wheelchairs travel
Clean and lubricate key locations based on ramp usage frequency and climate conditions (outlined by your transit agency). Lubrication procedures should be performed by transit agency maintenance personnel.
Page 41 Page 43

Over 300 Braun Dealers Worldwide
® "Providing Access to the World"
®

The Braun Corporation (“Braun”) warrants it’s ramp against defects in material and workmanship for three years, provided the ramp is installed, operated and maintained in conformity with this manual. Warrantied replacement parts are covered until the expiration of the Braun warranty or 90 days, whichever is longer. The Braun warranty covers the cost of labor for any repair or replacement covered under the warranty during the first year of the warranty period, if an approved Braun dealer completes the warranty work. The warranty registration card accompanying this ramp is to be completed and returned to The Braun Corporation within 20 days of purchase. If Braun receives the warranty card, the warranty period begins on the day the ramp is put into service. If Braun does not receive the warranty card, the parts warranty will expire in three years, and the labor warranty will expire in one year from the manufacture date of the ramp. The Braun warranty does not cover any defects in the motor vehicle on which the ramp is installed, or defects in the ramp caused by any defect in the motor vehicle. The warranty does not cover work deemed by Braun to be normal maintenance, service, or periodic adjustments necessitated by use or wear. The Braun warranty is null and void if any repair or maintenance work is completed during the warranty period using parts not authorized by Braun or if, as determined solely by Braun, the ramp is damaged through accident, misuse or abuse, or altered in any way.
THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, PERFORMANCE, OR OTHERWISE, WHICH ARE HEREBY EXCLUDED. IN NO EVENT SHALL BRAUN BE LIABLE FOR ANY DAMAGES, WHETHER DIRECT, IMMEDIATE, INCIDENTAL, FORESEEABLE, CONSEQUENTIAL, OR SPECIAL, ARISING OUT OF OR IN CONNECTION WITH ITS PRODUCT.
To contact Braun or to obtain a list of Braun authorized dealers, call 1-800-THE-LIFT or visit our web site at www.braunlift.com The Braun Corporation Winamac, Indiana
When processing any warranty claims (parts, repairs, etc.), all requests must be processed through The Braun Corporation Product Support Department. Call 1-800-THE LIFT during normal working hours. Product Support will issue a Return Material Authorization (RMA) number and detail the procedures required for processing returns and/or authorizing credit.
The ramp identification information is provided on the Braun Serial No./Series No. identification tag and the two warranty cards (supplied with ramp). The lift identification information must be provided when filing a warranty claim or ordering parts.

33778 March 2007 33778 March 2007
All illustrations, descriptions and specifications in this manual are based on the latest product information available at the time of publication. The Braun Corporation reserves the right to make changes at any time without notice. All illustrations, descriptions and specifications in this manual are based on the latest product information available at the time of publication. The Braun Corporation reserves the right to make changes at any time without notice.
© The Braun Corporation © The Braun Corporation
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1.20 Power to Ramp But No Pump Operation | 1.21 Ramp wiring harness Remove relays from sockets. Using volt meter, test (probe) wires/terminals at relay sockets: Red = +12/24 V Black = -Ground Blue = V (when Stow switch is activated) Orange = V (when Deploy switch is activated) 1.22 Faulty relay(s) Replace 1.22 Loose connection(s) Clean and tighten 1.24 Broken wire(s) Repair 1.25 Wire terminal(s) Crimp tightly to wire | p.30 | |
| 1.20 Power to Ramp But No Pump Operation | p.30 | ||
| 2.10 No Operation continued | 2.11 See 1.00 'ULIW2XW0LFURVZLWFKRXWRIDGMXVW- See Microswitches in Systems Descrip- ment or damaged tions for details 2.13 Drift Out Microswitch harness dis- Connect, repair or replace connected, damaged or otherwise damaged 2.14 Pump motor brushes worn Contact Braun Product Support - replace pump | p.30 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.