Page 1 of the Smeg SNLRV596X user manual — 1. SAFETY AND SAFETY REQUIREMENTS 122
Page 1 · click to enlarge
Page 1

Contents

1. SAFETY AND SAFETY REQUIREMENTS 122

2. PLACEMENT OF TOP 124

3. ELECTRICAL CONNECTION 126

4. GAS CONNECTION 127

5. GAS REGULATION 129

6. LAST ACTIONS 133

7. USE OF THE HOB 135

8. CLEANING AND MAINTENANCE 139

THESE INSTRUCTIONS ARE VALID ONLY FOR THE COUNTRIES OF DESTINATION WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE FRONT SIDE OF THIS MANUAL.

INSTRUCTIONS ON THE INSTALLETEUR: are intended for use in the qualified technician which must control the gas installation and carry out its installation, commissioning and inspection.

INSTRUCTIONS FOR THE USER: provide user advice, description of the controls and proper cleaning and maintenance work for the appliance.

Page 2 of the Smeg SNLRV596X user manual — 1.  SAFETY AND OPERATING RULES
Page 2 · click to enlarge
Page 2

Presentation

1. SAFETY AND OPERATING RULES

THIS MANUAL IS PART OF THE APPARATUS AND SHOULD THEREFORE BE KEPT AT ITS FULL REACH THROUGHOUT THE LIFE OF THE HOB. WE ADVISE YOU TO READ THIS MANUAL AND ALL THE INSTRUCTIONS CAREFULLY BEFORE USING THE HOB. ALSO KEEP THE SERIES OF SUPPLIED MOUTHPIECES. THE APPARATUS MUST BE INSTALLED BY QUALIFIED PERSONNEL IN ACCORDANCE WITH APPLICABLE STANDARDS. THIS APPARATUS IS INTENDED FOR DOMESTIC USE AND MEETS THE STANDARDS CURRENTLY IN FORCE. THE APPARATUS IS CONSTRUCTED TO PERFORM THE FOLLOWING FUNCTION: FOOD PREPARATION AND HEATING; ANY OTHER USE SHOULD BE CONSIDERED AS IMPROPER. THE MANUFACTURER SHALL REJECT ANY LIABILITY FOR USE OTHER THAN THAT INDICATED. DO NOT LEAVE THE PACKAGING IN THE HOUSE UNATTENDED. SEPARATE THE VARIOUS WASTE MATERIALS FROM THE PACKAGING AND HAND THEM OVER TO THE NEAREST DISPOSAL CENTRE. CONNECTION TO THE EARTH IS MANDATORY ACCORDING TO APPLICABLE SAFETY REQUIREMENTS OF THE ELECTRICAL INSTALLATION. THE PLUG TO BE ATTACHED TO THE POWER CABLE AND ITS ELECTRICAL SOCKET SHALL BE OF THE SAME TYPE, AND COMPLY WITH APPLICABLE REQUIREMENTS. THE ELECTRICAL OUTLET SHALL BE ACCESSIBLE IN THE CASE OF A BUILT-IN DEVICE. NEVER PULL THE PLUG ON THE CABLE FROM THE SOCKET. IMMEDIATELY AFTER INSTALLATION, SELECT THE STOVE BY FOLLOWING INSTRUCTIONS GIVEN FURTHER DOWN. IN CASE OF MALFUNCTION, THE DEVICE SHALL BE DISCONNECTED FROM THE POWER GRID AND CONTACT THE NEAREST TECHNICAL SERVICE CENTRE. NEVER TRY TO FIX THE DEVICE.
Page 3 of the Smeg SNLRV596X user manual — Presentation
Page 3 · click to enlarge
Page 3

Presentation

AFTER EACH USE OF THE HOB, CHECK THAT THE CONTROL BUTTONS ARE IN POSITION "NUL' (OFF). THE IDENTIFICATION PLATE CONTAINING TECHNICAL DATA, SERIAL NUMBER AND MARKING IS VISIBLY PLACED UNDER THE COVER. THE PLATE ON THE COVER SHALL NOT BE REMOVED UNDER ANY CIRCUMSTANCES. BEFORE CONNECTING THE DEVICE, ALWAYS ENSURE THAT IT IS ATTUNED TO THE SAME TYPE OF GAS AS IT WILL FEED. THEREFORE, CHECK THE PICTURE AT THE BOTTOM OF THE HOOD. DO NOT PUT POTS ON THE GRILLS OF THE HOB THAT ARE NOT COMPLETELY SMOOTH AND REGULAR. DO NOT USE DISHES OR (GRILL) PANS THAT GO BEYOND THE CIRCUMFERENCE OF THE HOB. THE APPARATUS IS INTENDED FOR USE BY ADULTS. DO NOT ALLOW THE HOB TO BE USED AS A TOYS BY CHILDREN WITHOUT ADEQUATE SUPERVISION. THE COMMISSION HAS ALSO ADOPTED A PROPOSAL FOR A DIRECTIVE ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO THE PERMISSIBLE SOUND POWER LEVEL OF MOTOR VEHICLES AND THEIR TRAILERS.

The manufacturer shall assign any liability for personal injury or material damage or caused by neglect of the above requirements, or by decomposing separate parts of the apparatus, or using non-original spare parts.

Page 4 of the Smeg SNLRV596X user manual — 2.  PLACEMENT OF TOP
Page 4 · click to enlarge
Page 4

2. PLACEMENT OF TOP

Diagram . .
Diagram . .

The next procedure requires masonry or carpentry and therefore must be carried out by a skilled technician. The installation is possible on structures of different materials, such as masonry, metal, solid wood and plastic laminated wood, if it is heat resistant (T 90°C). For installation of the device, use no silicone or other insulating material but only the kneading gum supplied.

2.1.1 Confirmation of the structure of aid Make an opening in the top of the furniture with the dimensions shown on the image, keeping a minimum distance to the rear edge of 50 mm. This device is placed against walls higher than the workspace provided that distance .XThe symbol shall be marked "in the image' to avoid damage caused by overheating. Be sure that the fires of the cookers have a minimum distance to any vertical shelf above them. 750 mm.

Diagram . .
Diagram . .

Place the supplied insulating gasket precisely over the outer circumference of the opening made in the worksheet as shown on the pictures below, and try to connect it across the surface by slightly pressing it with your hands. Depending on the type of hob to be installed, you should take into account the sizes shown in the picture and remember that for both models the front and back must connect to the opening. Attach the hob to the furniture using the supplied brackets A Cut on edge B the excess gasket. The measurements of the next drawing are taken on the opening from inside the gasket.

Diagram . .
Diagram . .
Page 5 of the Smeg SNLRV596X user manual — 2.  PLACEMENT OF TOP
Page 5 · click to enlarge
Page 5

In case of installation on a neutral space with doors, one must be

Separator panel shall be placed under the stove top. Keep a minimum distance from 10 mm between the bottom of the appliance and top of the panel, which must be easily removed to reach the stove in case of technical intervention.

Smeg SNLRV596X — 2.  PLACEMENT OF TOP diagram (page 5)
Fig. 4

(90 cm mod.) Under the stove plate only ovens equipped with a cooling fan may be installed.

Page 6 of the Smeg SNLRV596X user manual — 3.  ELECTRICAL CONNECTION
Page 6 · click to enlarge
Page 6

3. ELECTRICAL CONNECTION

Check that the voltage and dimensioning of the power line correspond to the properties on the plate below the cap of the device. This plate must not be removed under any circumstances.

The sticker at the end of the cord shall be in conformity with the outlet and must also conform to the applicable requirements. Check that the power line is properly grounded.

Apply a multipole interruption mechanism to the supply line of the device with and distance between contacts at least 3 mm, in an easily accessible place and near the device.

Do not use reductors, adapters or power-off.

In the case of replacement of the power cable, the diameter of the wires of the new cable shall not be less than 1,5 mm

2 (cable of 3 x 1.5), and remember that the end to be connected with the device must have a minimum 20 mm longer grounding wire (yellow-green). Use only a H05V2V2-F or equivalent cord that is resistant to 90°C. The replacement of the cord may only be carried out by a specialist technician who will have to perform connection to the power grid according to the following schedule.

L = brown N = blue

For personal injury or material damage caused by neglect of the above requirements or by decompression of a separate part of the apparatus: the manufacturer shall reject any liability.

= yellow-green

Page 7 of the Smeg SNLRV596X user manual — / ISO 228-1
Page 7 · click to enlarge
Page 7

4. GAS CONNECTION The connection to the gas network can be made with a rigid copper tube or flexible pipe with continuous wall and in accordance with standards. To facilitate connection, the A-connection can be directed sideways at the back of the device; unscrew the hexagonal nut B, turn the connector A into the desired position and re-scrape the hexaneal nutB (the seal is ensured by a biconical brass ring). After the operation, check with a soap solution and never with a flame that seal is perfect. The hob is approved for methane gas G25 (2L 3B/P)

with a pressure of 25 mbar

- G20/G25 (2E+)

. For food with other types of gas see Chapter . GAS DYNAMOMETER CONTROL. The connector has an external thread of 1⁄2

/ ISO 228-1

).

Connection with rigid copper tube: connection to the gas network shall be such that it does not cause any kind of load on the appliance. The connection can be done with an adapter D with biconus. Connection with flexible tube: use only flexible tubes according to the applicable requirements.

Connection with flexible tube: Use only flexible tubes according to the applicable requirements (the marking AGREE AGB/GVV must be legible on the tube) and always place between the connecting piece A and the flexible tube D a suitable adaptor C. The adaptor C shall be provided with an internal cylindrical lead wire (ISO 228-1) at the end so that it is connected to the device and an external cone-shaped guide wire ( ISO 7-1) at its end for closing to the tube. Always the gasket supplied B between the connector A and the adaptor C - I'm sorry.

The flexible tube shall be so laid that the length of the pipes does not exceed 1,5 metres in maximum extension; check that the pipes do not come into contact with movable parts or become entangled.

- 20/25 mbar

Page 8 of the Smeg SNLRV596X user manual — 4.3 Disposal of combustion products
Page 8 · click to enlarge
Page 8

4.1 Connection to liquid gas

Use a pressure regulator and connect the bottle to the requirements of the standards. Please be sure that the nutrient pressure is in accordance with the values indicated in the table in Section .

4.2 Ventilation of rooms

The apparatus may only be installed in permanent ventilation spaces, as provided by the standards. In the departure in which the apparatus is installed, it shall be possible to flow as much air as necessary for regular combustion of the gas and any required ventilation at the start. The air intake openings protected by gratings shall be properly dimensioned (standard requirements) and so placed that they cannot become fully or partially clogged. The space must be ventilated to remove the heat and humidity caused by baking: voral, after prolonged use, it is recommended that a window be opened or possibly increased the speed of fans.

4.3 Disposal of combustion products

Diagram . .
Diagram . .

The disposal of combustion products should be ensured by wash-basins connected to a natural pull fireplace and the correct efficiency, through forced extraction. An efficient extraction system requires a precise design by a specialist qualified to do so, taking into account the positions and distances imposed by standards. After the work has been completed, the installer shall issue a declaration of conformity.

Page 9 of the Smeg SNLRV596X user manual — 5.1 Adaptation to the different types of gas
Page 9 · click to enlarge
Page 9

5. GAS REGULATION

Before cleaning or maintenance, the apparatus must be used Power off.

5.1 Adaptation to the different types of gas

Diagram . .
Diagram . .

The hob is approved for methane gas G25 (2L 3B/P)

. In the event of operation with other types of gas, the nozzle shall be replaced and primary air adjusted. To replace the mouthpieces and set the burners, remove the plate as described in the following paragraph.

Diagram . .
Diagram . .
1. Remove all rotary knobs, gratings, covers and flame distribution crowns; 2. Remove the screws and nuts A holding the burner supports; 3. The level regulator shall be fully of its position lamps; 4. then replace the burner nozzle according to the reference gas schedule; 5. adjust the primary air as described in paragraph .
Diagram . .
Diagram . .
Page 10 of the Smeg SNLRV596X user manual — 5.3 Liquid gas facility
Page 10 · click to enlarge
Page 10
Diagram . .
Diagram . .

5.3 Liquid gas facility

Screw A loosening and support B Deeply. M. e. g. a fixed key the burner nozzle C remove and assemble the right one, suitable for the type of gas used and following the structures in the reference tables. The force for screwing the burner nozzle may be applied to: 3 Nm do not exceed. Bring support B back in the original position, so burner nozzle C Perfectly covered. Control the air supply through the Venturi tube D slide until distance .X.b) The primary air flow rate is determined in the table in paragraph 5.5 above and reached by screw A Hold it. After performing all the settings, restore the seals with wax lacquer or equivalent material.

Diagram . .
Diagram . .
Diagram . .
Diagram . .
Diagram . .
Diagram . .
BurnerRated heat output (kW)Liquid gas . . 30/30 mbar DiameterBy-pass mm 1/100Limited D flow rate g/h (W)Ebiet Debiet G30 g/h G31 mouthpiece 1/100 mm Auxiliary burner (1)1.05483033 (*)38076 75 Medium speed (2)1.65623033 (*)380 120 118 Quick (3)3.1854345 (*)750 225 222 Very fast (4)3.3875565 (*)1200 240 236 Double crownDoubleInternal (5) External (5)1.15483033 (*)38076 75 3.8925565 (*)1200 284 278 Fishpan (6)2.9824345 (*)800 211 207
Page 11 of the Smeg SNLRV596X user manual — 5.4 Methane gas setting
Page 11 · click to enlarge
Page 11

5.4 Methane gas setting

The hob is approved for methane gas G20/G25 (2E+) - G25 (2L 3B/P) at a pressure of 20/25 mbar - 25 mbar . In order to bring the apparatus into service for this type of hole, the same operations as described in paragraph .7.5.3 Liquid gas dynamometer device but now with the nozzle and primary air for methane gas, as indicated in the following table and in section .5.5 Primary air dynamometer set-up. After performing all the settings, restore the seals with wax lacquer or equivalent material.

BurnerRated heat output (kW) Methane gas . . G20/G25 20/25 mbar Diameter nozzle 1/100 mmLimited flow rate (W) Auxiliary burner (1)1.0573420 Medium speed (2)1.6592480 Quick (3)3.1126750 Very fast (4)3.31301200 Double crowninternal (5)1.0573380 external (5)3.91401200 Fishpan (6)2.9123800
Rated heat output (kW)Methane gas . . G25 25 mbar Burner Diameter nozzle 1/100 mmLimited flow rate (W) Auxiliary burner (1)1.0576380 Medium speed (2)1.6598380 Quick (3)3.1130750 Very fast (4)3.31351200 Double crownInternal (5) External (5)1.0576380 3.91501200 Fishpan (6)2.9126800
Page 12 of the Smeg SNLRV596X user manual — 5.5 Setting up of primary air
Page 12 · click to enlarge
Page 12

5.5 Setting up of primary air

Diagram . .
Diagram . .
BURNERG20/G25 20/25 mbarG25 25 mbarG30/G31 28/37 mbar Auxiliary burner (1)1.51.01.0 Medium speed (2)1.51.01.5 Quick (3)1.00.51.5 Very fast (4)2.01.52.5 Double crowninternal (5)3.01.06.0 external (5)3.01.510.0 Fishpan (6)2.01.52.5

To recognize the burners on your hob, we refer to the drawings in section .

Page 13 of the Smeg SNLRV596X user manual — 6.2 Setting the minimum level for liquefied gas
Page 13 · click to enlarge
Page 13

6. LAST ACTIONS

After performing the above settings, reassemble the device by executing the instructions in paragraph .7.5.2 Removal of plate .

6.1 Setting the minimum level for methane gas

Put the components back on the burner and insert buttons onto the rods of the taps. Turn on the burner and put it in minimum position. Take the button away again and turn on the screw in or next to the rod of the crane (depending on the model), until you reach the smallest regular flame. Remount the button and check the stability of the flame from the burner (by turning the knob quickly from maximum to minimum position, the flame must not go out).

6.2 Setting the minimum level for liquefied gas

To set the minimum for liquid gas, the screw that is in or next to the bar of the crane (depending on the models) must be turned clockwise. The diameters of the by-pass for each burner are given in table .

After the gas adjustment, other than that of test turning, replace the plate on the device's cartridge with another one corresponding to the new type of gas. The plate is in the bag together with the supplied burner nozzle pieces.

Page 14 of the Smeg SNLRV596X user manual — 6.4 Gas taps lubrication
Page 14 · click to enlarge
Page 14

6.3 Classification of burners on the hob

Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 14 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 15 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 16 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 17 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 18 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 19 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 20 · 6.3 Classification of burners on the hob
Smeg SNLRV596X — 6.3 Classification of burners on the hob diagram (page 14)
Fig. 21 · 6.3 Classification of burners on the hob
Diagram . .
Diagram . .
Diagram . .
Diagram . .
Diagram . .
Diagram . .

BURNER 1 Auxiliary burner 2 Half-fast 3 Quickly 4 Very fast 5 Double crown 6 Vispan

6.4 Gas taps lubrication

The gas cranes may be more difficult to rotate and block over time. Then clean them on the inside and change the grease. This should be done by a specialist technician.

Page 15 of the Smeg SNLRV596X user manual — 7.1 Inflammation of burners
Page 15 · click to enlarge
Page 15

7. USE OF THE HOB

Diagram . .
Diagram . .

Before switching on the burners, check that the flame distributors, caps and gratings are properly mounted. In the quick burner, the niche A co-ordinate with the pen B. The supplied grid C must be used for the wok (Chinese pan). The reduction D is supplied only with open grid models and should be used for small pans.

7.1 Inflammation of burners

The controls are clear and easy to use thanks to the embossed indicators: each button has a line leading to the corresponding burner. The set position is indicated by the extended end of the button or by the pointer shown on it. (Only for certain models) The double wreath burner, operated by two buttons, is indicated by two lines: a long line that refers to the small middle burner, and a short line that points to the outer burner. The double wreath burner is formed by an auxiliary torch and a quick burner; it is operated by two different buttons that can be used together or individually, depending on the requirements.

The gas burners are equipped with electronic ignition. It is sufficient to turn the dial counterclockwise on the symbol of minimum flame and press it until the gas pit is lit. For the models equipped with safety valves, hold down the button for about 2 seconds to activate gas and protective device transmission. If the flame of a burner is released as soon as the button is released, then the action must be repeated and the button held down for longer.

In the models that are equipped with safety valves, in case of accidental ignition, after a pause of approx. 20 seconds the automatic security system block the gas through even when the crane is open.

Page 16 of the Smeg SNLRV596X user manual — 7.3 Pans Diameter
Page 16 · click to enlarge
Page 16

7.2 Practical beckons for the use of burners For better efficiency of the burners and minimum gas consumption, pans with a flat regular bottom should be used and with a lid, appropriate size to the burner (see section .7.3 Diameter of the pots). During cooking, avoid burns or damage to the work surface by keeping all dishes or (grill) pans within the circumference of the hob with a minimum distance from 3-4 cm To the buttons.

7.3 Pans Diameter

Diagram . .
Diagram . .

(*) See page 134 for numerical positioning of burners on the plate.

  • 7.4 Use of a grill plate When using a grill board, you should take the following into account:
  • maintain a distance of 160 mm between the edge of the grill plate and the side wall;
  • If one of the burners near the rear wooden wall is a triple burner, you must maintain from that wall a distance of 160 mm to the edge of the grill plate;
  • Be careful not to let the flames of the burners go outside the edge of the grill plate;
  • let the burners burn under the grill plate for 10 minutes at maximum power, and you can set them to minimum position. Never use the plate for more than 45 minutes.
Page 17 of the Smeg SNLRV596X user manual — Electric plates
Page 17 · click to enlarge
Page 17

7.5 Electric plates 7.5.1 Electrical plates ignition The hotplates can be equipped with an electric plate of different diameters. These are operated by and switch and the ignition takes place by turning the button in the desired position.

The controls are clearer and easier to use thanks to the embossed indicators: each button has a line leading to the corresponding electric plate. The set position is indicated by the extended end of the button or by the pointer shown on it. A warning light on the front panel indicates that the plate is switched on.

7.5.2 Use of electric plates The plates offer the advantage of ultra-fast preparation. We mention an institutional table purely as directions.

Diagram . .
Diagram . .

To butter and chocolate etc. to melt. To heat small amounts of liquid.

To thaw frozen food and prepare stews, to cook food at boiling point or just below.

To cook food that should be brought to boiling point 4 Normal, for soft roast and fish.

To bring large amounts of water to boiling point 6 Maximum, for frying.

Page 18 of the Smeg SNLRV596X user manual — Electric plates
Page 18 · click to enlarge
Page 18
Diagram . .
Diagram . .
  • WARNING (s) When first activated or in any case if the plate has not been used for a long time, it must be dried by switching on to position 1 of the switch 30 minutes to eliminate any moisture absorbed by the insulating material. Remember for good use:
  • To turn the plate on only after you put the pan on.
  • Pans to use with a flat, thick bottom.
  • Never use pans smaller than the plate.
  • Dry the bottom of the pan before putting it on the plate.
  • During the preparation of food with oil and fat that can easily ignite, the user must not remove from the device.
  • After use, the plates remain warm for a long time: to avoid burns you should not touch them with your hands or place objects on them.
  • Once you see cracks in the surface of the plates, the device must be immediately disconnected from the power supply and contact the nearest approved technical assistance centre.
Page 19 of the Smeg SNLRV596X user manual — 8.1 Cleaning
Page 19 · click to enlarge
Page 19
8. Cleaning AND MAINTENANCE Do not use steam jets for cleaning the appliance.
Diagram . .
Diagram . .

8.1 Cleaning

For a long life of the cooking surface it is necessary to clean regularly after each use and after cooling.

8.1.1 Ordinary daily cleaning of the plate To clean and keep working surfaces in good condition, only use suitable products which do not contain abrasives or acidic chlorine-based substances. Method of use: pour the product onto a damp cloth and clean the surface, carefully remove it and dry with a soft cloth or a seam of dam deer leather. 8.1.2 Food stains or residues

Do not use metal sponges or sharp scrapers to damage the surfaces. Use the normal products (no abrasives) with a non scratching sponge and possibly wood or plastic 0 kitchen utensils.

Accurately remove and dry with a soft cloth or a seam of dam deer leather.

Page 20 of the Smeg SNLRV596X user manual — Cleaning of the parts of the hob
Page 20 · click to enlarge
Page 20

8.2 Cleaning of the parts of the hob The grills, hats, crowns and burners can be removed which facilitates cleaning. Clean them in warm water with a non abrasive detergent and be careful to remove all remains. Wait till they are completely dry before placing them back.

NOTE: The following components must not be washed in the dishwasher. When the stove is used normally, stainless steel pan carriers and burner covers will get slightly tan because of high temperature. You can clean these components with extremely fine sanding sponges or similar products available on the market. Then use specific gloss pastes to re-glow the steel. At your local approved technician you will find professional products for cleaning and handling household appliances.

8.2.1 Bougs and safety devices For proper operation, the ignition plugs and safety devices must always be kept clean.

Check them regularly and clean them with a damp cloth if necessary.

8.2.2 Electric plate After use, the electric plate must be treated with the specially available equipment to keep it in good condition and ensure that its surface is always clean and shiny. This is necessary to prevent any oxidation (rust).

8.2.3 The lid For the glass or steel lid models, cleaning shall be done with lukewarm water without using rough cloths or abrasives. To facilitate cleaning at the back of the hob, remove the lid by lifting it upwards.

Replace the lid after cleaning and check that it is properly applied. Before opening the cover, any liquids that have fallen on it must be removed. Do not close the lid if the burners or electric plate are switched on or still warm.

Ask about the Smeg SNLRV596X

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Smeg SNLRV596X

Be the first to ask — other owners or our team will answer.

Original document

Smeg SNLRV596X manual PDF

20 pages·1.6 MB·Stove·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…