Page 1 of the Smeg SNLD24 user manual — 1.  SAFETY AND OPERATING INSTRUCTIONS 30
Page 1 · click to enlarge
Page 1

Contents

1. SAFETY AND OPERATING INSTRUCTIONS 30

2. INSTALLATION OF THE DEVICE 32

3. GAS REGULATION 36

4. LAST ACTS 38

5. USE OF THE HOB 39

6. CLEANING AND MAINTENANCE 41

THESE INSTRUCTIONS ARE VALID ONLY FOR THE COUNTRIES OF DESTINATION WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE FRONT SIDE OF THIS MANUAL.

INSTRUCTIONS ON THE INSTALLETEUR: are intended for use in the qualified technician which must control the gas installation and carry out its installation, commissioning and inspection.

INSTRUCTIONS FOR THE USER: provide user advice, description of the controls and proper cleaning and maintenance work for the appliance.

Page 2 of the Smeg SNLD24 user manual — 1.  SAFETY AND OPERATING RULES
Page 2 · click to enlarge
Page 2

Presentation

1. SAFETY AND OPERATING RULES

THIS MANUAL IS PART OF THE APPARATUS AND SHOULD THEREFORE BE KEPT AT ITS FULL REACH THROUGHOUT THE LIFE OF THE HOB. WE ADVISE YOU TO READ THIS MANUAL AND ALL THE INSTRUCTIONS CAREFULLY BEFORE USING THE HOB. ALSO KEEP THE SERIES OF SUPPLIED MOUTHPIECES. THE APPARATUS MUST BE INSTALLED BY QUALIFIED PERSONNEL IN ACCORDANCE WITH APPLICABLE STANDARDS. THIS APPARATUS IS INTENDED FOR DOMESTIC USE AND MEETS THE STANDARDS CURRENTLY IN FORCE. THE APPARATUS IS CONSTRUCTED TO PERFORM THE FOLLOWING FUNCTION: FOOD PREPARATION AND HEATING; ANY OTHER USE SHOULD BE CONSIDERED AS IMPROPER. THE MANUFACTURER SHALL REJECT ANY LIABILITY FOR USE OTHER THAN THAT INDICATED. DO NOT LEAVE THE CONTENTS OF THE PACKAGING UNATTENDED IN THE HOUSE. SEPARATE THE VARIOUS WASTE MATERIALS FROM THE PACKAGING AND HAND THEM OVER TO THE NEAREST DISPOSAL CENTRE. CONNECTION TO THE EARTH IS MANDATORY ACCORDING TO APPLICABLE SAFETY REQUIREMENTS OF THE ELECTRICAL INSTALLATION. THE PLUG TO BE ATTACHED TO THE POWER CABLE AND ITS ELECTRICAL SOCKET SHALL BE OF THE SAME TYPE, AND COMPLY WITH APPLICABLE REQUIREMENTS. THE ELECTRICAL OUTLET SHALL BE ACCESSIBLE IN THE CASE OF A BUILT-IN DEVICE. NEVER PULL THE PLUG ON THE CABLE FROM THE SOCKET. IMMEDIATELY AFTER INSTALLATION, SELECT THE STOVE BY FOLLOWING INSTRUCTIONS GIVEN FURTHER DOWN. IN CASE OF MALFUNCTION, THE DEVICE SHALL BE DISCONNECTED FROM THE POWER GRID AND CONTACT THE NEAREST TECHNICAL SERVICE CENTRE. NEVER TRY TO FIX THE DEVICE. AFTER EACH USE OF THE HOB CHECK THAT THE CONTROL BUTTONS ARE IN POSITION (OFF). THE IDENTIFICATION PLATE CONTAINING TECHNICAL DATA, SERIAL NUMBER AND MARKING IS VISIBLY PLACED UNDER THE COVER. THE PLATE ON THE COVER SHALL NOT BE REMOVED UNDER ANY CIRCUMSTANCES.
Page 3 of the Smeg SNLD24 user manual — Presentation
Page 3 · click to enlarge
Page 3

Presentation

ZET GEEN PANS ON THE GRILLS OF THE HOB THAT ARE NOT COMPLETELY SMOOTH AND REGULAR.

NO DISHES OR (GRILL) PANS THAT GO BEYOND THE CIRCUMFERENCE OF THE HOB.

THE APPARATUS IS INTENDED FOR USE BY ADULTS. DO NOT ALLOW THE HOB TO BE USED AS A TOYS BY CHILDREN WITHOUT ADEQUATE SUPERVISION.

THE COMMISSION HAS ALSO ADOPTED A PROPOSAL FOR A DIRECTIVE ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO MACHINERY AND EQUIPMENT DESIGNED TO FACILITATE THE MOVEMENT OF WORKERS WITHIN THE COMMUNITY.

The manufacturer shall assign any liability for personal injury or material damage or caused by neglect of the above requirements, or by decomposing separate parts of the apparatus, or using non-original spare parts.

Page 4 of the Smeg SNLD24 user manual — 2.2 Electrical connection
Page 4 · click to enlarge
Page 4

2. INSTALLATION OF THE DEVICE

The next procedure requires masonry carpentry and should therefore be The Commission has also proposed that the aid be granted to a company which is not subject to any of the conditions laid down in Article 107 (1) TFEU. The installation is possible on structures of different materials, such as Masonry, metal, solid wood and plastic laminated wood, as the but heat resistant (T 90°C).
Smeg SNLD24 — 2.  INSTALLATION OF THE DEVICE diagram (page 4)
Fig. 1

To secure the device on the worktop, enter the four mounting brackets (A) as shown in the figure until they are clamped. Then you need to use the four self-tapping screws through the slots B to secure the device on the worktop.

Smeg SNLD24 — 2.  INSTALLATION OF THE DEVICE diagram (page 4)
Fig. 2

2.2 Electrical connection

Check that the voltage and dimensioning of the power line correspond to the properties on the plate below the cap of the device. This plate must not be removed under any circumstances.

The sticker at the end of the cord shall be in conformity with the outlet and must also conform to the applicable requirements. Check that the supply line is properly grounded.

Page 5 of the Smeg SNLD24 user manual — 2.3 Ventilation of rooms
Page 5 · click to enlarge
Page 5

Apply a multipole interruption mechanism to the supply line of the device with and distance between contacts at least 3 mm, in an easily accessible place and near the device.

Do not use reductors, adapters or power-off.

In the case of replacement of the power cable, the diameter of the new wire shall not be less than 0.75 mm

2 (cable of 3 x 0.755) and remember that the end to be connected with the device must have a minimum 20 mm longer grounding thread (yellow-green). Use only a H05V2V2-F or equivalent cord that is resistant to 90°C. The replacement of the cord may only be carried out by a specialist technician who will have to perform connection to the power grid according to the following schedule.

L = brown N = blue

Smeg SNLD24 — Ventilation of rooms diagram (page 5)
Fig. 3 · Ventilation of rooms

For personal injury or material damage caused by neglect of the above requirements or by decompression of a separate part of the apparatus: the manufacturer shall reject any liability.

2.3 Ventilation of rooms

The apparatus may only be installed in permanent ventilation spaces, as provided by the standards. In the departure in which the apparatus is installed, it shall be possible to flow as much air as necessary for regular combustion of the gas and any required ventilation at the start. The air intake openings protected by gratings shall be appropriately dimensioned (standard requirements) and so placed that they cannot become fully or partially blocked. The space must be ventilated to remove the heat and humidity caused by baking: after prolonged use, voral opening or possibly increasing the speed of fans is recommended.

= yellow-green

Page 6 of the Smeg SNLD24 user manual — / ISO 228-1
Page 6 · click to enlarge
Page 6

2.4 Disposal of combustion products

The disposal of combustion products should be ensured by wash-basins connected to a natural pull chimney and the correct efficiency, through forced extraction. An efficient extraction system requires a precise design by a specialist qualified to do so, taking into account the positions and distances imposed by standards. After the work has been completed, the installer shall issue a declaration of conformity.

2.5 Gas connection The connection to the gas network can be made with a rigid copper tube or with a Flexible tube with a wall which is continuous and in accordance with the requirements of the standards. After the operation, check with a soap solution and never with a flame that seal is perfect. The hob is approved for methane gas G25 (2L)

- G20/G25 (2E+)

with a pressure of 25 mbar

. For food with other types of gas, see Chapter . . The connector has an external thread of 1⁄2now gas (ISO 7-1)

/ ISO 228-1

Smeg SNLD24 — / ISO 228-1 diagram (page 6)
Fig. 4

Connection with rigid copper tube: connection to the gas network shall be such that it does not cause any kind of load on the appliance. The connection can be done with an adapter D with biconus, always the supplied gasket C must be inserted between them. Connection with flexible tube: Use only flexible tubes according to the applicable requirements and always place between the connector A and the flexible tube E the gasket supplied C.

Connection with flexible tube: Use only flexible tubes according to the applicable requirements (the marking AGREE AGB/GVV must be legible on the tube) and always place between the connecting piece A and the flexible tube D a suitable adaptor C. The adaptor C shall be provided with an internal cylindrical lead wire (ISO 228-1) at the end so that it is connected to the device and an external cone-shaped guide wire ( ISO 7-1) at its tip for closing to the tube. Always the gasket supplied B between the connector A and the adaptor C - I'm sorry.

- 20/25 mbar

Page 7 of the Smeg SNLD24 user manual — 2.6 Connection to liquid gas
Page 7 · click to enlarge
Page 7
Diagram . .
Diagram . .

The flexible tube shall be so laid that the length of the pipes does not exceed 1,5 metres in maximum extension; check that the pipes do not come into contact with movable parts or become entangled.

2.6 Connection to liquid gas

Diagram . .
Diagram . .

Use a pressure regulator and connect the bottle to the requirements of the standards. Please be sure that the nutrient pressure is in accordance with the values indicated in the table in section .3.2 Tables of burner and sprayer performances.

The hob has been tested and can only be used on G25 gas with a pressure of 25 mbar, and therefore no longer need to be adjusted.

(W) Auxiliary burner 1.05 76 380 Medium speed 2.15 110 450 Fast 3.0 128 650 Ultrafast 3.25 135 1400

Page 8 of the Smeg SNLD24 user manual — / ISO 228-1
Page 8 · click to enlarge
Page 8

3. GAS REGULATION

The work is always carried out by the electrical power supply to

the device is switched off.

The hob is approved for methane gas G25 (2L)

- G20/G25 (2E+)

with a pressure of 25 mbar

. For food with other types of gas, see Chapter . . The connector has an external thread of 1⁄2now gas (ISO 7-1)

. 3.1 Replacement of the hob The primary air does not need to be controlled during this procedure.

/ ISO 228-1

1. Remove the gratings, remove all caps and flame distributor wraps; 2. unscrew the burners with a 7 mm tube wrench; 3. replace the burners sprinklers according to the gas you want to use, in the way described in section .3.2 Tables with properties of burners and sprayers. 4. Put the burners back in place.
Smeg SNLD24 — / ISO 228-1 diagram (page 8)
Fig. 7

- 20/25 mbar

Page 9 of the Smeg SNLD24 user manual — 3.3 Classification of burners on the hob
Page 9 · click to enlarge
Page 9

3.2 Tables with properties of burners and sprinklers

BurnerRated heat output (kW)Liquid gas . . Diameter nozzle 1/100 mmBy-pass mm 1/100Limited flow rate (W)Debt g/h G30Debt g/h G31 Auxiliary burner (1)1.0550273507675 Medium speed (2)1.86533450130128 Quick (3)2.37543800166164 Ultrafast (4)3.594631.6253250
Diagram . .
Diagram . .
BurnerRated heat output (kW)Methane gas . . G20/G25 20/25 mbar Diameter nozzle 1/100 mmLimited flow rate (W) Auxiliary burner (1)1.0572350 Medium speed (2)1.897450 Quick (3)2.3103800 Ultrafast (4)3.51331500

3.3 Classification of burners on the hob

Smeg SNLD24 — 3.3 Classification of burners on the hob diagram (page 9)
Fig. 9 · 3.3 Classification of burners on the hob
Smeg SNLD24 — 3.3 Classification of burners on the hob diagram (page 9)
Fig. 10 · 3.3 Classification of burners on the hob

BURNER 1 auxiliary burner 2 Half-fast 3 Fast 4 Ultra fast

Page 10 of the Smeg SNLD24 user manual — 4.3 Gas taps lubrication
Page 10 · click to enlarge
Page 10

4. LAST ACTIONS

After performing the above settings, reassemble the device by executing the instructions in paragraph .

After the gas type is set, the label in the food warm-up room should be replaced by the label corresponding to the new gas type. The label is available from the nearest Accredited Assistance Centre.

4.1 Setting the minimum for methane gas

Smeg SNLD24 — 4.1 Setting the minimum for methane gas diagram (page 10)
Fig. 11 · 4.1 Setting the minimum for methane gas

Light the burner and put it in its smallest position. Remove the button from the gas tap and turn on the screw that is in or next to the rod of the crane (this depends on the models), until a regular minimum flame occurs. Remount the button and check the stability of the burner flame (if the knob is quickly turned from the largest to the smallest position, the flame must not go out). Repeat this operation on all gas taps.

4.2 Setting the minimum level for liquefied gas

To set the minimum for liquid gas, the screw that is in or next to the bar of the crane (depending on the models) must be turned clockwise. The diameters of the by-pass for each burner are given separately in Table .3.2 Tables with characteristics of burners and nozzles .

4.3 Gas taps lubrication

The gas cranes may be more difficult to rotate and block over time. Then clean them on the inside and change the grease. This should be done by a specialist technician.

Page 11 of the Smeg SNLD24 user manual — 5.1 Adjuster knob burners
Page 11 · click to enlarge
Page 11

Instructions for User

5. USE OF THE HOB

5.1 Adjuster knob burners

Before igniting the stove burner, check

whether the flame distributor wrenches are in place with their caps, and make sure that the holes A of the flame distributors correspond to the spark plugs and thermocouples.

The grid B can be used for a .wok . (Chinese)

pan). To prevent wear of the worktop, we have provided the blade with an increased grille C: it shall be placed under pans of a diameter greater than that specified in the table in paragraph 5.3 Diameter of the pots. Pans of more than 28 cm diameter may in any case only be used on the central burner.

Smeg SNLD24 — 5.1 Adjuster knob burners diagram (page 11)
Fig. 12 · 5.1 Adjuster knob burners

Each button shall indicate the burner used to set it.

Smeg SNLD24 — 5.1 Adjuster knob burners diagram (page 11)
Fig. 13 · 5.1 Adjuster knob burners

You're welcome. The device is equipped with an electronic ignition mechanism. It is sufficient to press the button and on the symbol of minimum

until the ignition has occurred.

The gas burners are equipped with electronic ignition. It's

sufficient to rotate and press the dial counterclockwise on the symbol of minimum flame until the gas pit is lit. For the models equipped with safety valves, hold down the button for about 2 seconds to activate gas and protective device transmission. If the flame of a burner is released as soon as the button is released, then the action must be repeated and the button held down for longer. Once the burner is lit, you can control the flame as desired. Check that the control buttons are in position (off) after use of the hob.

flame

Page 12 of the Smeg SNLD24 user manual — 5.3 Pans Diameter
Page 12 · click to enlarge
Page 12

Instructions for User

5.2 Practical beckons for the use of burners

For better efficiency of the burners and minimum gas consumption: use pans with a lid, appropriate dimensions in relation to the burner, to avoid that flame hits the sides (see section . Reduce the flame at the time of boiling as much as is necessary to prevent overboiling. To avoid burning or damage to the plate during preparation, all pans and dishes must be placed within the circumference of the hob. When using oil or fat, be very careful because they may catch fire if overheated.

5.3 Pans Diameter

BURNERS 1 auxiliary burner 2 Half-fast 3 Fast 4 Ultra fast

Ø min. and max. (in cm)

12-14 16-20 18-24 20-26

Below you will find the diameters of the pans that are suitable for use with the raised pan carrier. Ø min. and max. (cm) 1. Auxiliary torch 16-26 2. Semi fast 22-26 3. Fast 24-28 4. Ultra fast 26-34

Page 13 of the Smeg SNLD24 user manual — 6.1 Cleaning of stainless steel
Page 13 · click to enlarge
Page 13

Instructions for User

6. CLEANING AND MAINTENANCE

The electrical power supply of the Device is switched off.

6.1 Cleaning of stainless steel

To keep the stainless steel in good condition, it should be cleaned regularly after each use, after cooling the oven.

6.1.1 Ordinary daily cleaning Always use specific products that do not contain any abrasive or acidic chlorine-based substances for cleaning and preserving stainless steel surfaces. Method of use: pour the product onto a damp cloth and clean the surface, carefully remove it and dry with a soft cloth or a seam of dam deer leather. 6.1.2 Food stains or residues Do not use metal sponges or sharp scrapers to damage the surfaces. Use normal steel products, not abrasive, and use wooden or plastic tools. Accurately remove and dry with a soft cloth or a seam of dam deer leather.

6.2 Cleaning of the parts of the hob The caps and the flame dispenser wraps can be removed to easily clean them; wash them off with warm water and a non-squeezing cleansing agent. Make sure all the cakes are removed and wait for them to come be perfectly dry.

Smeg SNLD24 — 6.1 Cleaning of stainless steel diagram (page 13)
Fig. 14 · 6.1 Cleaning of stainless steel
LET OPdo not wash these parts in the

dishwasher. Can be soaked with hot water and a cleansing agent.

Replace the flame-divide wraps, and make sure they are in place with their caps. Make sure the holes A The flame distributors correspond to the spark plugs and thermo-elements.

For proper operation, the ignition spark plugs and thermocouples must always be clean. Check them regularly and clean them with a damp cloth if necessary. Any dry residue should be removed with a wooden stick or needle.

Page 14 of the Smeg SNLD24 user manual — CLEANING AND MAINTENANCE
Page 14 · click to enlarge
Page 14
Page 14 of the Smeg SNLD24 user manual — CLEANING AND MAINTENANCE

Ask about the Smeg SNLD24

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Smeg SNLD24

Be the first to ask — other owners or our team will answer.

Original document

Smeg SNLD24 manual PDF

14 pages·850 KB·Stove·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…