EN
Sharp logo
Official user manual

Sharp KC-G40EU

18 pages·8.2 MB·Air Cleaner·PDF·ENDEFRITNLJA
Sharp KC-G40EU
Table of Contents 62 sections CHARACTERISTICS · (KC-G60EU / KC-G50EU) · 7-factor detection by 6 sensors · SENSOR DETECTION · … ShowHide
Page 1 of the Sharp KC-G40EU user manual — Humidity
Page 1 · click to enlarge
Page 1

CHARACTERISTICS

A unique combination of air treatment technologies Triple filtration system + Plasma cluster + Wetification

REFRESHED With a balanced release of positive and negative ions, plasma cluster air cleaning is a natural process.

CAPTURES DUST PARTICLES The pre-filter collects dust particles larger than approx. 240 microns.

WETTED Controls humidity by automatic detection of temperature and humidity. *1: .VOC, NOx, SOx. The deodorisation performance at a smell consisting of a component in a 1m3 test container may differ from the deodour performance in practice. *2: *When the air circulates through the filter system. Sensor technology constantly monitors and adapts to the air quality and conditions of space.

REDUCES ODOUR The fragrance filter absorbs harmful gases*1 and various, common household odours.

REDUCES SMALL DUST PARTICLES, POLLEN & FUNGUS SPORES*2 The HEPA filter captures 99.97% of dust particles greater than 0.3 microns.

INTelliGENT MODUS If there is a person or pet in the sensor zone*4 (*4: see EN-5)

(KC-G60EU / KC-G50EU)

  • . . If the person or pet is not moving much (for example when the person/animal is asleep), then the unit automatically switches to a silent airflow.
  • . .If it is dark in space, the front display, purity monitoring and air uilate LED automatically switch off. If there is no movement within the sensor zone

6 sensors that de-tect 7 factors closely control the au-tomatic operation.

  • .The front display, the cleanliness monitoring and the air outlet LED goes off, the humidity stops and the device switches to minimal luch current for energy saving.
  • • If the humidity level in space is higher than 80% and the light is in space, plasma clusters are released by a strong airflow.

7-factor detection by 6 sensors

SENSOR DETECTION

PM2.5 (dust particles less than 2.5 microns), etc.

Substance (sensitive)

Tobacco smoke, household dust (waste, residues and waste from mites, fungus spores, pollen)

Smell Tobacco, cosmetics, alcohol, spray and other fragrances

  • •In intelligent mode you can manually switch off the humidifier INor (see NL-8)
  • .The front display and the air outlet LED automatically switch ON and OFF based on the room brightness. (If the lights are set to "Auto." See NL-11)
  • . . If the motion sensor detects that no one has been in space for a set time, it is assumed that the room is empty.
  • • You can change the brightness of the display/monitor, sensor sensitivity and motion sensor detection time. (See NL-11, NL-12)
  • .The motion sensor may detect movements other than those of a person or pet. (flap curtain etc.)

Humidity

Air humidity level in the room

Light Light intensity in space

Movements*3 Movements of persons or pets

*3: .Detect only if the intelligent mode is ac- duced.

Air exhaust LED · Front display, purity monitoring · Temperature Room temperature

Page 3 of the Sharp KC-G40EU user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 3 · click to enlarge
Page 3

IMPORTANT SAFETY INSTRUCTIONS

When using electrical devices you should always observe some essential safety requirements, including: WARNING . Please always take the following considerations into account to avoid danger of electric shock, fire or personal injury:

  • to electrical shocks, heat accumulation or fire.
  • Do not pull the plug out of the socket with wet hands.
  • Do not place the unit near gas appliances or a fireplace.
  • Maintenance to this air cleaner shall be carried out only by Sharp approved maintenance personnel. Please contact the nearest service centre in case of problems, or for adjustment or repair.
  • Do not use the air cleaner in areas where insecticides have been sprayed. Do not use the unit in areas where oil components, incense, burning cigarette sparks or chemical vapours are present in air. Do not use the unit in areas where it can get wet, such as a bathroom.
  • Be careful when cleaning the unit. Aggressive cleaning agents can damage the outside.
  • When the unit needs to be moved, remove the water reservoir and air humidifier and lift it from both sides of the device.
  • Do not drink the water contained in the humidifier or reservoir.
  • Do not expose the unit to water. If you do, this could lead to a short circuit or an electric shock.
  • Change the water in the reservoir daily with clean tap water and regularly clean the water tank and air damping container (see NL-8, NL-13, NL-14). Remove all water from the water reservoir and air humidifier when not used. If water is left in the reservoir or air humidification container, it can form a breeding ground for fungi and bacteria and a source of bad smells. In rare cases, such bacteria may pose a health risk. Note . . What to do if the unit interferes with radio or TV reception If the air cleaner disturbs the radio or televisiNL reception, then perform one or more of the following measures:
  • Read all instructions carefully before using the unit.
  • Use only a 220-240 volt socket.
  • This device can be used by children aged 8 years and over, persons with reduced physical, sensory or intellectual abilities or lack of experience and knowledge as long as they are under supervision or have been instructed on the use of the apparatus in a safe manner and aware of the danger during use. Kids aren't allowed to play with the device. Cleaning and maintenance must not be performed without supervision by children.
  • If the power cord is damaged, it shall be replaced by the manufacturer, his maintenance representative, Sharp approved maintenance staff or other authorised personnel to exclude any potential risk dressing.
  • Pull the plug out of the socket if you are e.g., before performing maintenance, when removing, fixing and repositioning the filter or if you do not use it for a long time. If you do not, this may result in short circuit which leads to an electric shock or fire.
  • Do not use the unit if the power cord or plug is damaged or if the connection to the socket is loose.
  • Dust the plug regularly.
  • Do not insert fingers or foreign objects into the air intake or air outlet.
  • Always hold the plug when removing the power cord and never pull the cord. If you do not, this may result in short circuit which leads to an electric shock or fire.
  • If you move the unit, do not damage the power cord with the swing wheels. If you do not do this and the power cord gets damaged, it can lead to an electric shock, heat degeneration or fire.
  • Don't damage the power cord, this can lead
  • Adjust or reposition the receiving antenna.
  • Increase the distance between air cleaner and radio or TV.
Page 4 of the Sharp KC-G40EU user manual — GUIDELINES FOR USE OF FILTERS
Page 4 · click to enlarge
Page 4
  • Connect the air cleaner to an electrical outlet in a power group other than that of the radio or television receiver.
  • Consult your dealer or a qualified radio or TV mechanic.
  • The vehicle shall be equipped with a device to prevent the failure of any part of its engine.
  • Use only clean tap water. If you use other water, the risk of fungi or bacteria is created.
  • Do not shake the water reservoir while holding the carrying lever.
  • Do not remove the moistening filter from the filter frame unless you replace it.
  • Avoid spilling water from the humidifier, if you remove it or clean it.
  • Do not remove the float. If this goes loose, see NL-15.
  • Do not use cleaning agents for maintenance of the humidifier container and cover. This can cause deformations, pollution and cracks (water leakage).
  • Avoid brushing hard when maintaining the rear panel. INSTALLATION GUIDELINES

PRECAUTIONS FOR USE

  • Do not block the air intake or air outlet.
  • Do not place the unit near or above hot objects, such as a stove or oven, nor in places where it can be exposed to steam.
  • Always use the unit upright.
  • If you move the unit, use the handles on either side of the unit. Do not move the unit if it is in use.
  • If the unit is on a floor that is easily damaged, on an uneven surface or on a thick carpet, lift it if you move it.
  • If you move the unit with the swing wheels, push it slowly in horizontal direction.
  • During the movement, make sure that the unit is off and removes the water reservoir and air humidifier. Make sure your fingers don't get pinched.
  • Do not switch on the unit if filters, water reservoirs and air-humidification bin are not installed properly or not correctly.
  • The HEPA filter and the fragrance filter cannot be washed and used again. If you do, the filter performance will not be improved and it may also result in electrical shocks or malfunctions.
  • Clean the outside only with a soft cloth. Do not use volatile liquids or cleaning agents. The unit surface may be damaged or cracked if you thinner paint with benzene or sanding powder. In addition, the sensors may fail.
  • The frequency of decalcification depends on the hardness and purity of water used; the harder the water, the more frequent it will have to be descaled.
  • Do not expose the air cleaner to water.
  • If you pulverize the water reservoir, make sure that no water leaks from the water tank.
  • Dry the outside of the water reservoir if you spilled water.
  • Do not use hot water (40oC or warmer), chemicals, aromatics, dirty water or other harmful substances. If you do, this can be done.
  • Avoid places where the sensors are exposed to direct wind. If you do not, this may result in malfunctions of the unit.
  • Avoid places where furniture, fabrics or other objects may come into contact with the unit and interfere with air inlet.
  • Avoid places where the air cleaner is exposed to condensation or major temperature changes. An appropriate room temperature is between 0 and 35oC.
  • Place the unit on a flat and stable surface and ensure that good air circulation is possible. If the unit is placed on a heavy carpet, this light can shake. Place the unit on a flat surface to prevent water from leaking out of the reservoir and air dampening container.
  • Avoid places where fat or oily smoke is produced. If you do not, this may result in cracks on the outside of the unit as well as sensor failures.
  • The dust collection function of the unit is effective even if the distance between the unit and the wall is only 3 cm. The surrounding walls and floors can get dirty. Place the unit at a distance from the wall. The wall directly behind the air outlet can become dirty over time. If you use the unit in the same place for a long time, clean the surrounding walls regularly.

GUIDELINES FOR USE OF FILTERS

  • Follow the instructions in this manual for proper care and maintenance of filters. (see NL-13, NL-14, NL-15)
Page 5 of the Sharp KC-G40EU user manual — PRECAUTIONS FOR USE
Page 5 · click to enlarge
Page 5
Diagram . .
Diagram . .
PRELIMINARY 5 6 1 20° 2 20° 3 7 1 Handles (2 locations) 8 Sensor (internal) 2 Temperature/humidity/scent* (*KC-G60EU / KC-F50EU) 3 Air exhaust (front) 9 4 Stopper swivel wheel (right & left) 5 Control panel 4 To lock a swiveling wheel stopper (right and left) 6 Front valve (installable) Locked Unlocked 7 Front display Front 8 Unit 9 Swing wheel (4 locations) Rear Detection range 7 8 Light sensor 9 Do not install the unit at any of the following places. 1 The light sensor may not function properly. 6 10 11 2 Directly underneath a In the shade 12 light luminaire. 3 Motion sensor (KC-G60EU/KC -G50EU) 4 The sensor zone is the area indicated below 13 5. Front 14 30° 1.6m (Plugform varies by country.) 30° 1 Water reservoir 7 Backgate 2m 2 Tank cap 8 Air outlet (back) Right and left 2.3m 3 Air damping filter 9 Air exhaust LED(white) 4 Vlotter 10 HEPA filter 5 Air humidifier 11 Scent filter 2m 30° 30° 12 Rear panel (prefilter) Dust(sensitive) sensor / 6 13 Air intake sensor filter 14 Power cord/plug 1Water reservoir7Rear valve 2Tank cap8Air exhaust (back) 3Air-humidification filterr 9Air exhaust LED(white) 4Fleet10HEPA Filter 5Air humidifier11Scent filter 6Dust(sensitive) sensor/sensor filter12 13 14Rear pane (pre-filter) Air intake Power cord/plug
Page 6 of the Sharp KC-G40EU user manual — 7 6 5 3 2 1
Page 6 · click to enlarge
Page 6
Diagram . .
Diagram . .

Press the button with " " to start the unit.

1ON / OFF STRONG7ON/OFF TIMER button, indicator light (white) <3 sec. push > FILTERRESET button 2INTelliGENT MODUS button, indicator light (white) 3Button cleaning by IONENDOUCHE, indicator light (white)8DISPLAY SELECTINL button < 3 sec. Press > CHILDSLOT button 4Plasma clusterionSPOT button, indicator light (white) 9CHILDSLOT indicator light (white) 5AIR EXPECTATION ON/OFF button, indicator light (white)10FILTERRESET indicator light (orange) 6MODUS button, indicator light (white)11Light sensor

7 6 5 3 2 1

1Wet/temperature monitoring approximately indicates the humidity level / temperature in the room. The setting of humidity cannot be adjusted. Humidity of 20% to 90% is shown. 2 0 % o f 90% or less Temperature is shown from 0oC to 50oC. - 1 oC f 50oC or less Wattage storage indicates wattage at current use. Timer monitoring Specifies the time or remaining time on the ON/OFF timer.4Patrol lamp (green/orange/red) (see NL-9, NL-10) 5Scent lamp(white) (KC-G60EU / KC- G50EU) Indicates that the odour sensor detects smell. 6Dust lamp (white) Indicates that the substance is detecting normal dust; 7PM2.5 lamp (white) Indicates that the substance detects sensitive sensor fine dust. (dust particles less than 2,5 microns) 8Motion sensor (KC-G60EU / KC-H50EU) 2Plasma cluster ion lamp (blue)9Purity monitoring Indicates ambient air quality in the room in 7 levels, based on colour changes. Blue Red Clean Impure 3Light bulb Wet Green Wet Wet humidifier Out of red (flash) Unit needs water
Page 7 of the Sharp KC-G40EU user manual — CLEAN MODE BY ION SHOWER AUTO MODE (KC-G40EU)
Page 7 · click to enlarge
Page 7

PREPARATION

Always pull the plug out of the socket.

FILTER SYSTEM

Remove the rear panel.

Install the filters in the correct follower-, as shown.

Remove the plastic bag that is attached to each filter.

Install the rear panel to the.

OPERATION

START/STOP

INTELLIGENT MODE (KC-G60EU/KC -G50EU)

START STOP

The fan speed is automatically controlled depending on the 7-factor detection. (See NL-1)

CLEAN MODE BY ION SHOWER AUTO MODE (KC-G40EU)

The unit emits plasma clusterions over 10 minutes by means of a strong airflow collecting dust and reducing static electrical time for 10 minutes. After this, the sensitivity of the dust sensor is automatically adjusted to "High" in order to quickly detect impurities and to clean air vigorously for 50 minutes.

The fan speed is automatically controlled depending on the 5-factor detection. (PM2.5/normal substance/tempe-

  • When the process is completed after 60 minutes, the unit returns to its previous control mode. It is possible to switch from this program to another one during use.
  • The plasma clusters cannot be "disrupted." (See NL-10)
  • The front display, purity monitoring and the air exhaust LED automatically switch ON and OFF based on room luminous intensity. (If the lights are set to "Auto." See NL-11)
Show 6 more labels / short text on this page
HEPA filter · Label · Back panel · Scent filter · HEPA Filter Scent filters · Click
Page 8 of the Sharp KC-G40EU user manual — CANCEL
Page 8 · click to enlarge
Page 8

PLASMA CLUSTERING SPOT MODE

WETTING SETTING

FILLING OF THE WATER RESERVOIR

Use this mode if you want to remove persistent smells, bacteria and other substances from clothing, sofa dressings and curtains.

Remove the water reservoir.

Adjust the front valve manually.

Fill the water-reser voir with tap water.

  • High density plasma clusters only in forward direction.
  • Provides a stronger flow of luch for 8 hours. When the operation is complete, the unit returns to its previous control program.
  • The plasma clusters cannot be "disrupted." (see NL-10)

SELECT MODE

Turn the cap firmly to prevent leaking.

Install the water reservoir.

SLEEP POLLEN MAX MED LAYER

SLEEP The unit is silent and the fan speed is automatically adjusted depending on the amount of air impure. The front display, purity monitoring and air exhaust LED are automatically switched off. (If the lights are set to "Auto." See NL-11)

AAN UIT

POLLEN The sensitivity of the DUTSENSOR is automatically adjusted to .HOW . and quickly detects impurities such as dust and pollen in order to clean air vigorously.

CHILD LOCK

If the unit is used and the humidity is ON in one of the modes shown in the table below, then the unit automatically controls the humidity by detecting temperature and air-humidity. (except for: the modes MAX/MED/LAAG.)

Control panel is locked.

CANCEL

TemperatureHumidity ALL MODES (EXCL. MAXIMUM/MED/LOW/SLAAMSLEEPAP) MODE ~18 oC65 %65 % 18 oC~24 oC60 %65 % 24 oC~55 %60 %

3 sec. longer

3 sec. longer

Click

Page 9 of the Sharp KC-G40EU user manual — PATROL LOW HUMIDITY AND LOW TEMPERATURE
Page 9 · click to enlarge
Page 9
Diagram . .
Diagram . .

Choose the time frame. The unit stops automatically as soon as the time limit is reached. Choose the time frame. The unit will start automatically as soon as the chosen time period has expired.

(if unit is OFF) (if the unit is ON)

PATROULLE EFFUNCTION The sensor detects when the temperature or humidity needs your attention and makes this clear with the patrol light. Both the function "Patrouille low humidity and low temperature" as well as "Patrouille high temperature and high humidity" are active. (This function informs you about the condition of a room. The unit cannot adjust the temperature and reduce humidity)

PATROL LOW HUMIDITY AND LOW TEMPERATURE

This function lets you know that the air in space is dry and the temperature is low. When the patrol light turns red, the unit operates with a slightly stronger airflow than in intelligent mode (auto-mode).

Patrol lightIf the sound is set to "ON." (See NL-12)EnterTemperature and humidity zone (picture below) Air humidity/temperature monitoring (for 30 seconds)Beeping sound Red"%" light is onBeep (one time)Dry(3) "oC" light flashesBeep (one time)Low temperature Green(Normal)NoneNot dry or low temperature(1)·(2)

If the space is dry and the temperature is low, viruses can survive more easily. We recommend that you increase the humidity with the humidity adjustment and to increase temperature by heating devices suitable for room conditions.

Source of the material: Dr. Makoto Shoji, directu van Shoji internal medicine and pediatrics clinic in Sendai City, Miyagi Prefecture, Japan

Right FigureAbsolute humidity*1Virus EnvironmentSurvival rate*2 (1)More than 11 gEnvironment less suitable for viruses to survive0% to a small percentage (2)11 g or lessEnvironment in which viruses can survive5% (3)7 g or lessEnvironment suitable for viruses to survive20%

*1 .The absolute humidity is the total mass of water vapour present in 1 m3 air, expressed as g, regardless of temperature. The humidity generally used for a weather forecast is called relative humidity. This is the ratio of partial water vapour pressure to the vapour pressure of water at a given temperature, expressed in %. Therefore, the absolute humidity is approx. 8 g at 15oC and 18 g at 30oC, even with an equal relative humidity of 60%. *2 The survival of viruses released into the air after 6 hours in any environment.

  • The unit does not detect the existence of viruses.
  • A patrol light that "green carbs" does not guarantee prevention of infection. Use this as a reference to create an environment to prevent infection during daily life.
  • By adjusting the humidity to approx. 55% to 65% while in intelligent mode (automode), the unit controls humidity, but does not make any changes based on virus environment.
Show 7 more labels / short text on this page
• Temperature · • • (oC) · ■ • · . · Relative humidity (%)
Page 10 of the Sharp KC-G40EU user manual — PATROL HIGH HUMIDITY AND HIGH TEMPERATURE
Page 10 · click to enlarge
Page 10
Diagram . .
Diagram . .

If the plasma cluster function is on, then the plasma clusteri bulb on the front display is switched on. (see EN-6)

The squeaky sound of the patrol function is standard on "Out." You can change this setting to "On" or to "Cancel Patrouille function." (See NL-11, NL-12)

PATROL HIGH HUMIDITY AND HIGH TEMPERATURE

This function lets you know that the humidity and temperature are high. When the patrol light turns orange or red, the unit automatically stops the humidity. (However, if the unit is in MAX/MED/LAAG mode, the humidity does not stop)

Patrol light youIf the sound is set to "ON." (See NL-12) - Air humidity/temperature monitoring (throughout sound 30 seconds)EnterTemperature and humidity zone (picture below) Beeping sound Red (blinks)"oC" light flashesPage • for 30 seconds)High temperature and high humidityD Red"oC" light goes onPage • for 30 seconds)C Orange"oC" light goes onNoneRelatively high temperature and high humidityB Green(Normal)NoneNo high temperature or humidityA

We recommend drinking water or lowering room temperature.

Directive on the prevention of heat stroke in daily life

Temperature standardActivity Overviewprecautionary measures D HazardRisks that may arise in all activitiesFor the elderly, there is a very likely risk of heat stroke even in rest. Don't go out there and get to a cooler room. C Highly urgent warningAvoid the bright sun and watch for room temperature rise if you stay in this space. B WarningRisks that may arise in medium or more intensive activitiesRest regularly if you are exercising or doing intensive work. A CarefulRisks that may arise in the event of heavy activitiesGenerally, the risk is low but people may suffer from intensive training or heavy work.

This is not a function to prevent heat stroke. Use this function as assistance.

Show 7 more labels / short text on this page
Temperature · ' · & · % · (oC) · $ · Relative humidity (%)
Page 11 of the Sharp KC-G40EU user manual — Type of institution
Page 11 · click to enlarge
Page 11

MODIFY THE DIFFERENT SETTINGS

You can change the functions in the table "Type of settings" as follows.

Diagram . .
Diagram . .

Select "Configure Number" from the table below.

Diagram . .
Diagram . .

Set

KC-G40EU

Press the on/off button to complete the setting.

Type of institution

FunctionInstitution Control lights You can select the brightness of the front display, purity monitoring and air outlet LED.Auto (default) Light automatically ON or OFF based on the luminous intensity in the room. Lots of light in the room: Light is ON Space is dark: Lights are OFF Darker Turn off ● . If this is set to . . Then the light goes off. ● . .The light for the humidification only blinks darker if the unit needs water. ● . .The patrol light only blinks/dimmed if room temperature or humidity needs your attention.

Disable

Page 12 of the Sharp KC-G40EU user manual — MODIFY THE DIFFERENT SETTINGS
Page 12 · click to enlarge
Page 12
FunctionInstitution Settings sound indication You can set the unit to beep when the water tank is empty.Cancel (default) TO Automatically restart If the power cord of the unit is disconnected or if there is a power failure, the unit resumes operation with previous settings as soon as electricity is available.Cancel ON (default) Adjust sensor sensitivity (F4-F7) Light Sensor Dust (Sensitive) Sensors Sensory Sensitivity (KC-G60EU/KC -G50EU) Motion Senser (KKC) You can set time until the motion sensor detects that no one is in space. You can also cancel the detection by the motion sensor.Layer Default (default) High TO (default detection time) ON (longer detection time), Cancel Settings patrol function You can set the unit to beep, if the patrol light turns red.You can also cancel the patrol function.ON (reporting using patrol light and sound) The unit beeps for up to 30 seconds. You can turn off the sound by pressing a button on the control panel. When the patrol light lights red, every hour a beep sounds. ON (only the patrol light sign-up) (default) Cancel
Page 13 of the Sharp KC-G40EU user manual — Sensor Filter
Page 13 · click to enlarge
Page 13

CARE AND MAINTENANCE

FILTER INDICATOR

WATER RESERVOIR

The filter reset indicator light goes after using approx. 720 hours. (30 days × 24 hours = 720 hours)

Clean the bin side with water.

RESET

Thorough cleaning to remove dirt.

Clean the inside of the waterreser voir with a soft sponge and tank cap with a cotton swab or toothbrush

more than 3 sec.

This is a reminder to perform the maintenance below. After performing maintenance, reset the filter indi-cator.

CARE INDEX

UNIT/ REAR PANE

Wipe it with a dry, soft cloth.

Sharp KC-G40EU — CARE INDEX diagram (page 13)
Fig. 7

Carefully remove dust with cleaning tools such as a vacuum cleaner.

Thorough cleaning to remove dirt.

Rear pane

1. Add a small amount of kitchen cleaner to water and leave for about 10 minutes weeks.

CAREFUL

Places Ref.

Do not press too much when you wipe the rear panel.

2. Rinse the kitchen cleaner with clean water. 3. Allow the filter to dry completely in a well ventilated area.

NL-13 2 Unit/Back Panel (Front Filter)

Sensor Filter

1. Remove the rear panel. 2. Remove the sensor filter. 3. If the sensor filter is excessively dirty, clean it with water and dry thoroughly.
Show 11 more labels / short text on this page
Tank cap · Toothbrush · Sensors · Rear panel (prefilter) · 1 Water reservoir · 3 Sensors · 4 Air-humidification filter · EN-14 Air-moisturisation container · Sensor filter · 5 HEPA filter · EN-15 Scent filter
Page 14 of the Sharp KC-G40EU user manual — CARE AND MAINTENANCE
Page 14 · click to enlarge
Page 14
Diagram . .
Diagram . .

1 After maintenance, place the parts correctly.

Remove the cover from the air conditioning container. Rinse with plenty of water.

If you remove the rod from the air damp filter, then attach it back to its original position.

  • . Do not remove the float and panel from the air humidifier bin. If these get loose, see NL-15.
1. Fill the drawer halfway to water. 2. Add a small amount of kitchen cleaner.

3 Wash away the kitchen cleaner or decalcifying agent with clean water.

Page 15 of the Sharp KC-G40EU user manual — Panel of the humidifier
Page 15 · click to enlarge
Page 15

FILTER REPLACEMENT HEPA-FILTER/SCENT FILTER

LIFE OF FILTERS

Remove the dust on the HEPA filter and smell filter.

The life of the filter depends on the operating conditions, use and location of the unit. The lifespan of a HEPA filter and an odour filter and replacement suggestions are based on air cleaning in a room where 5 cigarettes per day are smoked, with unit dust collection and unodorisation performance deteriorating to midway through the level of a new filter. We recommend that you replace the filter more regularly if the unit is used under conditions significantly more demanding than normal circumstances.

CAREFUL • Do not wash the filters. Do not expose these to sunlight.

HEPA FILTER

Maintenance only the labelled surface. Do not clean the other surface. The filter is breakable, so don't apply too much pressure.

  • HEPA filter About 10 years after opening
  • Scent filter About 10 years after opening
  • Air humidification filter About 10 years after opening

FRAGRANCE FILTER

Replacement filter model Please contact your dealer for the purchase of a replacement filter.

Both surfaces can be maintained. The filter can break if too much force is applied, so be careful.

went KC-G60EU KC-G50EU KC-G40EU

Some odours absorbed by the filters are broken down over time, causing some of the smells to develop. Depending on the conditions of use, especially if the unit is used in an environment which is significantly more demanding than a household environment, these additional odours can become stronger faster than expected. Replace the filter in such cases or if dust cannot be removed after maintenance.

(1 piece) FZ-D60HFE FZ-D40HFE FZ-D40HFE

(1 piece) FZ-G60DFE FZ-G40DFE FZ-G40DFE

FZ-G60MFE FZ-G60MFE FZ-G60MFE

Install the float and panel of the air humidifier

Panel of the humidifier

KC-G60EU

Air humidification filter

KC-G50EU / KC-G40EU

Fleet

*Don't throw these parts away.

1. Place the float under this tab.

Throwing away filters Dispose of used filters as waste in accordance with all local laws and regulations.

HEPA filter material:

  • Filter: polypropylene
  • Frame: Polyethylene Scent Filter Material:
3. Insert the lip on the other side of the float into the recess.
  • Filter: Paper
  • Frame: ABS resin Wet filter material:
2.. Insert the float's lip into the recess.
  • Filter: Rayon, polyester
Show 14 more labels / short text on this page
Label · Filtering HEPA Filter · Scent filter · Air transport · moisture filter · (1 piece) · Top edge rod (white) * · Filter frame (white), * · filter frame (grey) · pin (greys)* · lip · vlotter · cross-section
Page 16 of the Sharp KC-G40EU user manual — PROBLEM SOLUTION (the following items are not due to a defect)
Page 16 · click to enlarge
Page 16

PROBLEM SOLVING

Before contacting a repairer, please refer to the troubleshooting table below to ensure that the problem is not defective.

PROBLEM SOLUTION (the following items are not due to a defect)

Smell and smoke are holding. • . .Check the filters. If these are extremely dirty, clean or replace them. (See NL-15)

The purity monitoring light is blue, even when the air is not clean.

  • The air could have been contaminated when the unit was inserted. Pull the plug out of the socket, wait a minute and re-plug the unit.

The purity monitoring light is red, although the air is clean.

  • Dirty or blocked openings of the substance; sensitive sensors prevent sensor action. Carefully clean the sensor filter or back panel. (See NL-13).

The unit makes a clicking or ticking sound.

  • The unit can make clicking or ticking sounds when generating ions.

The air that the unit emits has a smell.

  • Check that the filters are extremely dirty.
  • Clean or replace the filters. (see NL-13, NL-14, NL-15)
  • Use only clean tap water. If you use other water, the risk of fungi or bacteria is created. The unit doesn't work if there's a cigarette air.
  • Install the unit at a location where sensors can detect cigarette smoke.
  • Check if there is dust in the openings of the substance (sensitive) sensors or whether they are blocked. If there is dust in it or if it is blocked, clean the sensor filter or back panel. (See NL-13) The FILTER RESET light is on.
  • After you have done maintenance or replaced filters, plug the plug into an outlet and then press the filter reset button. (See NL-13)

The front display is disabled. • If the lights are set to "Auto," then the light goes off automatically when it is dark in space. If the light is switched off, then the lamp is always off. If you do not want the light to be switched off, set the lights to "Darker" setting. (See NL-11) The light of the humidification on the front display does not turn on when the reservoir is empty.

  • The right humidity level for the room has been reached and the humidification stopped.
  • Check the tempex flutter for dirt. Clean the humidifier. Make sure that unit is on a flat surface. (See NL-14) The water level in the reservoir does not fall or very slowly.
  • Check that the air humidifier and water reservoir are properly installed. Check the air damp filter. (See NL-14)
  • If the filter is extremely dirty, clean or replace it. (See NL-15) The purity monitoring changes colour regularly.
  • The purity monitoring automatically changes colour when the substance is sensitive to sensor and odour sensor* detect impurities. If you are concerned about this change, you can adjust the sensor sensitivity. (see NL-11,NL-12) (*KC-G60EU/KC - G50EU) There is a deviation between the unit's humidity monitor and another hygrometer in space.
  • There is a difference in the humidity level within the same room.
  • The sensor has different measurement parameters.
  • If the wattage or temperature is displayed, change the display by pressing the DISPLAYSELEXINL button. (See NL-10) The unit's PM2.5 light does not correspond to the weather message or other local PM2.5 data.
  • The surroundings outside, inside and also of the house (the amount of traffic nearby, the number of floors of a home etc.) can cause a different reading than local PM2.5 data.
  • • o C" flashes
  • In space, viruses can survive because of the low room temperature. We recommend that you adjust the temperature using heating appliances. (See NL-9)
  • The temperature and humidity in the room are high. We recommend drinking water or lowering room temperature. (See NL-10)

ERROR STATEMENTS Please contact the Sharp Service Center if errors occur repeatedly.

Diagram . .
Diagram . .

Ensure that the air damp filter and the humidifier container are properly installed, then re-enable the device.

Pull the plug out of the socket, wait about a minute and plug back into the outlet.

Page 17 of the Sharp KC-G40EU user manual — GEN
Page 17 · click to enlarge
Page 17

SPECIFICATIONS

Model KC-G60EU KC - G50EU K C-G40EU

Power supply 220-240 V 50-60 Hz

Adjust fan speed MAX MED LAOW MAX Med LOW Max MED LOW

Fan speed (m3/hour) 408 240 72 306 180 60 240 120 60

AIR

CLEAN

Rated power (W) 72 38 5.0 53 26 5.0 31 12 5,0

GEN

Noise level (dBA) 53 48 24 52 47 19 46 40 19

Fan speed (m3/hour) 342 240 72 240 120 60 210 120 60

AIR CLEANING

Rated power (W) 55 40 6.5 33 14 6.5 24 14 6.5

& FIGHT

Noise level (dBA) 49 48 24 46 40 20 43 40 20 Humidity

GEN

(mL/uur) *1 630 470 200 450 300 150 400 300 150

Recommended space size (m2) *2 ~50 ~38 ~28 High density plasma clusters recommended space size [m2)*3 ~35 ~ 28 ~21

Water reservoir content (l) 3.0 2.5 2.5

Dust(sensitive)/light / Temperature & humidity

Sensors Dust (sensitive)/scent/light / Temperature & humidity/movement

Toughness length (m) 2.0

Afmetingen (mm) 370 (B) × 293 (D) × 660 (H) 345 (B) × 262 (D) × 631 (H) 345 (B) × 262 (D) × 631 (H)

Weight (kg) 10.5 9.2 9.2 9.2

  • *1
  • The degree of humidity depends on the temperature and humidity inside and outside. The degree of humidity increases as the temperature rises or humidity decreases. The degree of humidity decreases as the temperature drops or humidity increases.
  • Measurement conditions: 20oC, 30% humidity (JEM1426) *2
  • The recommended size of the space applies to an air cleaner used at maximum fan speed.
  • The recommended size of the space indicates which surface particles can be removed in 30 minutes. *3
  • The size of a space where about 7000 ions per cubic metre can be measured in the middle of the room, when the unit is located next to a wall, with settings of mode MED functioning and at an altitude of approximately 1.2 meters from the floor.
Diagram . .
Diagram . .

If the unit plug is inserted into a wall socket, then the unit consumes about 1.2 watt of standby power consumption to control electrical circuits. Pull the plug off the socket to save energy if you do not use the air cleaner.

Page 18 of the Sharp KC-G40EU user manual — SPECIFICATIONS
Page 18 · click to enlarge
Page 18

A. Information on waste disposal for users (private households)

1. In the European Union

DO NOT THROW AWAY THIS DEVICE WITH THE NORMAL HOUSEHOLD WASTE AND DO NOT BURN IT IN THE STOVE. Waste electrical and electronic equipment should be collected and treated SHEELD in accordance with local legislation. Separate collection encourages environmentally friendly treatment, recycling of materials and limits the final disposal of waste. UNCONFORMED REMEMBERMENT can be harmful to health and the environment because of certain substances! Bring used equipment to a local, usually municipal, collection point, if possible. If you have any doubts about the removal, please contact local authorities and ask for appropriate disposal method. FOR USERS ONLY IN THE EUROPEAN UNION AND ANY OTHER COUNTRIES; FOREnamel NORWAY AND SWITZERLAND: You are legally obliged to participate in separate collection. The above symbol is on electrical and electronic equipment (or packaging) to remind users of this. Users of PRIVATE HOUSEHOLDS are obliged to use existing collection facilities for used equipment. Return is free. If the equipment is used for SUCH PURPOSES, please contact your Sharp dealer who will inform you about the withdrawal. You may have to pay a contribution for the take back. Small products (and small quantities) can be processed by local storage facilities. For Spain: Contact the collection facility or local authorities for taking back your discarded products.

Please note: Your product is provided with this symbol. This means that waste electrical and electronic equipment must not be disposed of together with normal household waste. There is a separate collection system for these products.

2. In other countries outside the European Union

If you wish to dispose of this product, please contact the local authorities for information on appropriate disposal procedures.

For Switzerland: You can return waste electrical and electronic equipment to the dis-tributor free of charge, even if you do not buy a new product. Additional collection facilities are listed on the home page of www.swico.ch or www.sens.ch

B. Information on waste disposal for businesses.

1. In the European Union

If you have used the product for business purposes and want to dispose of it:

Please contact your SHARP dealer who will provide you with information about the product's withdrawal. You may have to pay a contribution for the take-back and recycling. Small products (and small quantities) can be processed by local collection facilities.

For Spain: Contact the collection facility or local authorities for the return of your discarded products.

2. In other countries outside the European Union

If you wish to dispose of this product, please contact the local authorities for information on appropriate disposal procedures.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Sharp KC-G40EU

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Sharp KC-G40EU

Be the first to ask — other owners or our team will answer.

Original document

Sharp KC-G40EU manual PDF

18 pages·8.2 MB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…