T ECHNICAL I NFORMATION

The Hub 10 Telco has been designed to conform to the following

Hub 10 Telco only

standards:

IEC 320

ISO 8802/3, IEEE 802.3

UL 1950, EN 60950, CSA 22.2 #950

22 VA

EMC

EN 55022 Class B, EN 50082-1, FCC Part 15 Class A,

CSA C108.8 Class A

(screened cables must be used to ensure

Hub 10 Telco & Management Module

compliance with these standards)

IEC 320

EN 60068 (IEC 68)

30 VA

440mm (17.3 ins)

224mm (8.8 ins)

44mm (1.7 ins) or 1U

0-50°C (32-122°F)

2.6kg (5.7lb)

or 19" rack or wall mounted using kit supplied

DUA1667-2AAA03

Show 28 more labels / short text on this page
Related Standards · Electrical · Power Inlet · Functional · Fuse Protection · 2 Amps · Safety · Power Consumption · Power Dissipation · 73 BTU/hr · Power Inlet · Environmental · Fuse Protection · 2 Amps · Physical · Power Consumption · Width · Power Dissipation · 100 BTU/hr · Depth · Environmental · Height · Operating Temperature · Weight · Humidity · 0-90% (non-condensing) · Mounting · free standing,
Page 2 of the 3Com II Hub 10 user manual — W ICHTIGE S ICHERHEITSINFORMATIONEN
Page 2 · click to enlarge
Page 2

S AFETY I NFORMATION

Please read the following safety information carefully before

type, this unit should be powered by 230V (2P+T) via an isolation

installing the Hub 10 Telco.

transformer ratio 1:1, with the secondary connection point labelled

Neutral, connected directly to Earth (Ground).

WARNING:

Installation and removal of the unit must be

Impédance à la terre

Connect the unit to an earthed power supply to ensure

This must be approved for the country where it will be used.

compliance with safety standards.

The cord set must be UL-approved and CSA certified.

It is essential that the socket outlet is installed near to the unit

The minimum specifications for the flexible cord are:

and is easily accessible. You can only disconnect the unit by

No. 18 AWG

removing the supply plug from the outlet.

Type SV or SJ

This unit operates under SELV conditions (Safety Extra Low

Voltage) according to IEC 950, the conditions of which are

The cord set must have a rated current capacity of at

maintained only if the equipment to which it is connected is also

least 10A.

operational under SELV.

The attachment plug must be an earth-grounding

The appliance coupler, i.e., the connector to the device itself and

type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P

not the wall plug, must have a configuration for mating with an

(15A, 250V) configuration.

EN60320/IEC320 appliance inlet.

The supply plug must comply with Section 107-2-D1,

France and Peru Only

Standard DK2-1a or DK2-5a.

This unit cannot be powered from IT

supplies. If your supplies are of IT

The supply plug must comply with SEV/ASE 1011.

L’ INFORMATION DE S ÉCURITÉ I MPORTANTE

Veuillez lire à fond l'information de la sécurité suivante avant

Seulement Pour La France et Le Pérou

d'installer le Hub 10 Telco.

Cette unité ne peut pas être mise en marche des sources de courant IT

(Impédance à la terre). Si vos sources de courant sont de type IT, cette

AVERTISSEMENT:

L'installation et l'enlèvement de l'unité

unité doit être alimentée par 230V (2P+T) via un rapport de

doivent être faits seulement par le personnel qualifié.

transformation d'isolation de 1:1, avec un point de connexion secondaire

Brancher l'unité à une source de courant mise à la terre pour

étiqueté Neutre, branché directement à la Terre (à la Masse).

assurer la conformité aux normes de sécurité.

La Cordon d'Alimentation Surmoulé

Celui-ci doit être approuvé pour le pays auquel il sera utilisé.

C'est essentiel que le socle soit installé près de l'unité et soit

accessible. Vous pouvez seulement débrancher l'unité en

Le cordon surmoulé doit être UL Certifié et CSA Certifié.

enlevant la fiche d'alimentation de la prise de courant.

Les spécifications minimales pour le cordon souple sont:

Canada:

Cette unité marche sous les conditions SELV (Safety Extra Low

No. 18 AWG

Type 5V ou SJ

Voltage) conformément à IEC950, ces conditions sont maintenues

seulement si le matériel auquel elle est branchée, est aussi en

exploitation sous SELV.

Le cordon surmoulé doit avoir une capacité de courant

calculée au moins de 10A.

Le socle de connecteur, c'est-à-dire, le connecteur à l'appareil

La fiche de fixation doit être un type mis à la terre avec

lui-même et non pas la prise murale, doit avoir une configuration

pour le branchement avec une admission d'appareil

une configuration NEMA 5-15P (15A, 125V) ou NEMA

6-15P (15A, 250V).

EN60320/IEC320.

W ICHTIGE S ICHERHEITSINFORMATIONEN

Bitte unbedingt vor dem Einbauen des Hub 10 Telco Einheit die

Herausziehen des Verbindungssteckers aus der Steckdose vom

folgenden Sicherheitsanweisungen durchlesen.

Stromnetz getrennt werden.

Ein- und Ausbau des Gerätes ist

Das Gerät wird mit Sicherheits-Kleinspannung nach IEC 950 (SELV

vorzunehmen.

= Safety Extra Low Voltage) betrieben. Angeschloßen werden

nnen nur Geräte, die ebenfalls nach SELV betrieben werden.

Das Gerät an geerdete Stromversorgung anschließen, um eine

Übereinstimmung mit den Sicherheitsbestimmungen zu

Die Anordnung der Gerätsteckvorrichtung, d.h. die

gewährleisten.

Steckverbindung am Gerät selbst im Gegensatz zum Wandstecker,

muß in den EN60320/IEC320 Zuführungsstecker am Gerät passen.

Es ist wichtig, daß der Netzstecker sich in unmittelbarer Nähe zum

Gerät befindet und leicht erreichbar ist. Das Gerät kann nur durch

Der Anschlußkabelsatz muß mit den Bestimmungen des Landes

übereinstimmen, in dem er verwendet werden soll.

Show 16 more labels / short text on this page
† · carried out by · qualified personnel only · Power Cord Set · USA and · Canada · 3-conductor · Denmark I · † · Switzerland I · USA et · le · 3-conducteur · nur von Fachpersonal · k · ö
Page 3 of the 3Com II Hub 10 user manual — H OW TO U SE THE H UB 10
Page 3 · click to enlarge
Page 3

I NTRODUCTION

The SuperStack™ II Hub 10 Telco (3C16672A) has two 12 port Telco

unit will be disabled during power-up until they are correctly configured

connectors on the front panel providing Ethernet TP port connections,

and enabled by management software. This is only necessary on units

and an AUI port on the rear panel. The rear panel also has a slot for a

which have ports assigned as standby. Standby ports in resilient link

3Com Transceiver Module or Bridge MicroModule: if fitted the module

pairs can only be configured on SuperStack II Hub 10 or LinkBuilder

will operate in addition to the AUI port. A range of different media

FMS II units.

Transceiver Modules is available from 3Com (see

Security features are described in the manual which comes with your

).

Hub 10 Management Module.

The Hub 10 Telco can be stand-alone or linked with other Hub 10,

By disabling ports on boot up and enabling them with management

LinkBuilder FMS II, FMS, 10BT or 10BTi units to form a stack of units of

software, you provide extra security for your unit.

different media. Stacking units gives you the benefit of a higher port

count while the stack is still seen by the network as a single 802.3

During the power up sequence, the main ports (on the front

repeater.

panel) will be disabled, BUT the AUI and Transceiver Module

ports will be enabled for periods up to 1 second. During this

The Hub 10 Telco is suited for use in the office where it can be

wall-mounted, rack-mounted, or free standing. Alternatively, the unit can

brief moment, the AUI and Transceiver Module ports will NOT

be rack-mounted in a wiring closet or equipment room. A mounting kit

be secure.

is supplied.

The Hub 10 Telco can be powered either from the AC mains supply, or

The Hub 10 Telco has been designed for use with the majority of known

through an optional 3Com Redundant Power System (3C565047) to

Telco connectors.

provide a more reliable supply. Contact your local supplier for details.

Cable fixings have been supplied for holding the Telco cables to the

unit. There are locations for these fixings to the left of the Telco

The Hub 10 Telco has been designed to conform to the IEEE 802.3

connectors.

standard for Local Area Networks. The unit provides all the standard

In the unlikely event that your Telco connector will not connect fully to

functions of an 802.3 repeater, including:

the Hub 10 Telco, we recommend that you:

Use a connector extension

Use a Telco connector with a different cable approach

You can connect any 802.3 transceiver to the unit using an AUI cable

connected to the AUI port on the rear panel. Alternatively, you can fit

one of the 3Com Transceiver Modules or a Bridge MicroModule into the

slot on the rear panel (see

Products and Bulletin Boards

).

A SuperStack II Hub 10 Management Module (3C16630A) or Advanced

You can connect the Hub 10 Telco to any other 10Base-T unit using port

RMON Module (3C16632) can be fitted to the Hub 10 Telco to provide

24, to form an inter-repeater link. You must switch port 24 to MDI to

, including statistics, resilient links and security

bypass the internal cross-over normally implemented by 10Base-T unit

. Only one Management Module or Advanced RMON Module is

ports. See

required for each stack. Refer to the guides accompanying the module

for details on how to manage an Hub 10 unit or stack.

H

ub 10 Management Module (3C16630A) and Hub 10 Advanced RMON

To manage this hub, you

ersion of the agent

Module (3C16632) offer resilience

eatures.

our Management Module.

Up to 16 resilient link pairs can be configured via management software.

for details.

To avoid the creation of loops during power-up, Hub 10 units provide a

Disable On Boot switch. If this switch is set to disable, all TP ports on the

3Com II Hub 10 — H diagram (page 3)
Fig. 2

H OW TO U SE THE H UB 10

Numbered elements in this diagram refer to numbered sections in the text.

The numbers, in bold, are used as references in the text.

Show 31 more labels / short text on this page
“ · Products and Bulletin · Boards · ” · Network Connections · Repeater Functions · Signal retiming · Preamble regeneration · Fragment extension · Automatic partition/reconnection · Management · “ · ” · f · ull SNMP management · features · “ · MDI Switch · ” · Resilience and Security · may n · eed · a new v · and security f · software · installed on y · See · “ · Stack · Management · ”
Page 4 of the 3Com II Hub 10 user manual — TCVR LED
Page 4 · click to enlarge
Page 4

Front Panel

The Transceiver Module port may partition if the SQE test pulse is

enabled on its transceiver. SQE test should be disabled on transceivers

used to connect 802.3 repeaters to the network.

A range of Telco connectors can be used with the Hub 10 Telco. Refer to

AUI LED

for more information.

The AUI LED lights red if the AUI port has partitioned. Refer to

STATUS

Do not over-tighten the screws on the Telco

, for information on what to do if a segment is partitioned.

connectors.

An AUI port connected to coaxial cable segment may partition

if the segment is incorrectly terminated.

The Media Dependent Interface (MDI) switch controls the operation of

The AUI port may partition if the SQE test pulse is enabled on its

transceiver. SQE test should be disabled on transceivers used to connect

port 24. The switch is recessed and can be operated using a ball-point

pen or similar instrument.

802.3 repeaters to the network.

In this position you can connect port 24 to a

workstation or any other DTE.

The UNIT LEDs indicate the position of this unit in the stack, providing a

MDIX

In this position you can connect port 24 to any

Management Module or Advanced RMON Module has been fitted to a

internal cross-over (X) port on another 10Base-T

unit in the stack. The appropriate UNIT LED will light green; if this unit

MDI

has a Management Module (or Advanced RMON Module) fitted, it will

repeater using normal twisted pair cable to form an

show as unit number 1. If the unit is in a stack which does not contain a

inter-repeater link.

Management Module or Advanced RMON Module, the UNIT LEDs will

not light.

To form an inter-repeater link using two Hub 10 Telcos, connect port 24

on unit 1 to any port on unit 2. Ensure that the MDI switch on unit 1 is

IN (MDI) and that if port 24 is used on unit 2, the MDI switch is OUT

(MDIX).

The Power LED lights green to indicate the power supply to the unit is

correct. If it is not lit, and:

The STATUS LEDs show the partition state of a port and whether or not

None of the ports work

Check the fuse in the IEC socket and the

fuse within the power cable's plug (if

the Link Pulse signal is present on the segment connected to a port

fitted).

The Link Pulse signal is being received and the segment

The AUI and Transceiver

The internal fixed fuse for the power

attached to the port is functional.

If the port does not

Module ports do not work,

supply to the AUI and Transceiver

transmit/receive, check the Disable On Boot switch, 15, is

but the twisted pair ports

Module ports has blown. Contact your

Enabled.

supplier.

The Link Pulse signal is being received and the port is

All ports function normally

The LED has failed. Contact your supplier.

partitioned from the network.

MGMT LED

Check the connections and the cable for any breaks in the

segment.

The MGMT LED indicates the status of the Management Module or

Advanced RMON Module if fitted.

Make sure the transceiver attached to the DTE is correctly

connected and powered up.

There is no Management Module or Advanced RMON

Check for illegal 802.3 configurations, in particular, loops.

Module fitted to the Hub 10 Telco or the internal

Check that the Disable On Boot switch,

, is set for units

connection to it has been broken.

with standby ports in resilient links.

The Management Module (or Advanced RMON

If the cause of the partition is found and corrected, the segment

Module) is fitted and functioning normally.

is reconnected automatically, after the first valid packet is

Management agent software is being downloaded.

transmitted to, or received from the segment.

There is a fault on the Management Module (or

The Link Pulse signal is not being received.

Advanced RMON Module) or one of the units in the

stack. Check all connections and refer to the

Check that the attached DTE is switched on.

Management Module guide for more information.

Check that the Link Pulse signal has not been disabled by

management software.

Check that the attached transceiver is not faulty.

The Packet LED flashes yellow whenever a packet is received on one of

the 12 twisted pair ports, the AUI port, or the Transceiver Module port.

If it is an inter-repeater link, check the setting of the MDI

switch.

If this LED does not flash, there are no packets being received by the

unit.

Carry out the checks recommended for when a STATUS LED

is red.

Check for no more than 4 repeater stacks in series, and that

The Collision LED flashes yellow when a packet collision has been

cable lengths do not exceed the maximum specified in the

detected on a segment connected to one of the 24 Telco ports, the AUI

standard for that medium.

port, or the Transceiver Module port.

If these checks do not identify the cause of a problem, it may be that the

Under normal 802.3 operation, collisions occur and cause the Collision

Hub 10 Telco or the device connected to the port is faulty. Contact your

LED to flash. The probability of collisions increases during heavy activity

supplier for further advice.

on the network. The Auto Partition/Reconnection function partitions a

TCVR LED

segment from the rest of the network if more than 64 consecutive

collisions are detected on that segment.

The TCVR LED lights red if the Transceiver Module port has partitioned.

for information on what to do if a segment is

partitioned.

A transceiver module port connected to coaxial cable segment

may partition if the segment is incorrectly terminated.

Show 30 more labels / short text on this page
24 Telco Ports · “ · Introduction · ” · “ · LEDs · ” · , · MDI Switch · Out · UNIT LEDs · In · Power LED · STATUS LEDs · Green · work · Red · Off · Green/(Yellow) · Green flashing · Red · Off · Packet LED · Collision LED · Refer to · “ · STATUS LEDs · ” · , · ,
Page 5 of the 3Com II Hub 10 user manual —
Page 5 · click to enlarge
Page 5

Rear Panel Connection

You can connect units together in a stack to form a single logical

Power Supply and Fuse

repeater. You need one Hub Expansion Cable (3C625) for each additional

3Com II Hub 10 — Rear Panel Connection diagram (page 5)
Fig. 3 · Rear Panel Connection

Correct fuse location L’emplacement du fusible correct Richtige Stellung der Sicherung

unit in the stack. The diagram below shows how you connect units

together. Do not use two cables to connect any two units to each other

- they will not work if you do this.

Spare fuse location - DO NOT USE L’emplacement du fusible incorrect - NE PAS UTILISER Falsche Stellung der Sicherung - NICHT VERWENDEN

Disconnect power from all units that will form part of the new

stack.

Connect the male hub expansion connector of one unit to the

female hub expansion connector of the next unit. Repeat this process

until all the units are connected together. Refer to

the number of units allowed in a stack.

The Hub 10 Telco automatically adjusts to the supply voltage.

If you intend to rack or wall mount the units,

The fuse is suitable for both 110V A.C. and 220-240V A.C.

connect the units after they have been mounted.

operation.

Disable On Boot Switch

To change the fuse, release the fuse holder by gently levering a

small screwdriver under the fuse holder catch. Only 2A

This switch is located behind the blanking plate covering the

anti-surge type fuses of the same type and manufacture as the

. The unit is shipped with this switch set to

Enable.

original should be used with the Hub 10 Telco. Close the fuse

3Com II Hub 10 —  diagram (page 5)
Fig. 4

holder.

AVERTISSEMENT:

Assurer que l'alimentation soit débranchée

avant d'ouvrir le couvercle du contenant du fusible.

EnableTP ports on front panel are enabled on power up. They may be subsequently disabled via management software. DisableTP ports on front panel are disabled on power up until management software enables them. This is required for standby ports in resilient links.

L'unité s'ajuste automatiquement à la tension d'alimentation.

Le fusible est convenable aux deux opérations 110 V C.A. et

220-240 V C.A.

Pour changer le fusible, dégager le contenant du fusible en

mettant doucement un petit tournevis sous l'arrêt de

contenant du fusible. Seulement les fusibles de types 2A

Management / Advanced RMON Module Power Cable

anti-transitoires du même type et fabricant que l'original

doivent être utilisés.

This plug, located behind the blanking plate, provides power to an Hub

WARNUNG:

Vor dem Öffnen der Sicherungshalterung das Gerät

10 Management Module or Advanced RMON Module, if fitted and

vom Netzstrom trennen.

connected. See the guide accompanying the module for installation

instructions.

Das Gerät stellt sich automatisch auf die

Versorgungsspannung ein. Die Sicherung ist sowohl für 110V

A.C. wie für 220-240V A.C. geeignet.

You can connect the unit to any 802.3 transceiver using an AUI cable

(sometimes known as a transceiver cable or drop cable). Connect one

Zum Auswechseln der Sicherung durch leichtes Heben mit

end of the AUI cable to the AUI port on the rear panel of the unit and

einem kleinen Schraubenzieher die Abdeckungsklappe der

the other end to the AUI port on the transceiver. Engage the slide locks

Sicherungshalterung lösen. Sicherungen nur durch gleichen

at both ends of the AUI cable.

Typ und Wert wie die Originalsicherung ersetzen. Sicherung

auswechseln und die Klappe der Sicherungshalterung wieder

Ensure that SQE test is disabled.

schließen.

Socket for Redundant Power System

A variety of 3Com plug-in Transceiver Modules or the Bridge

MicroModule can be installed in the Hub 10 Telco (see overleaf

for a list).

Only connect a 3Com Redundant Power System, option 3C565047, to

Transceivers provide direct network connections to different media.

this socket. For details, follow the installation instructions in the guide

accompanying the Redundant Power System.

Do not remove the Transceiver Module blanking

plate with the power still connected.

Management Module or Advanced RMON Module Slot

Ensure that SQE test is disabled.

The Hub 10 Telco can be fitted with an optional SuperStack II Hub 10

Management Module or Advanced RMON Module. When the module

To install a Transceiver Module, refer to the guide that accompanies it. If

has an IP/IPX address, you can then use SNMP management to manage

you subsequently remove the Transceiver Module, you must replace the

the stack containing the unit.

blanking plate to aid the circulation of cooling air and prevent the entry

of dust and debris.

Do not remove the Management Module blanking

plate with the power still connected.

For instructions on installing either module in an Hub 10 unit, refer to

The Hub 10 Telco is supplied with 4 self-adhesive rubber pads. If the unit

the guide that accompanies the module. You will need to remove the

is to be part of a free standing stack, apply the pads to the underside of

blanking plate to reveal the slot for the module.

the unit; stick a pad in the marked area at each corner of the unit. Place

the units on top of each other, ensuring that the pads of the upper unit

If you subsequently remove the Management or Advanced RMON

locate with the recesses of the lower unit.

Module from the Hub 10 unit, you must replace the blanking plate to aid

Do not apply the pads if you intend to rack or wall mount the unit.

the circulation of cooling air and prevent the entry of dust and debris.

Show 10 more labels / short text on this page
Hub Expansion Connectors · “ · Stacking Units · ” · for · Management Module slot, · Connector · AUI Port · Transceiver Module Slot · Self-adhesive Pads
Page 6 of the 3Com II Hub 10 user manual — 3C16632
Page 6 · click to enlarge
Page 6

Siting the Hub 10 Telco

Managing with an FMS Management Module

rack mounted stacks:

the module must be fitted to an FMS unit at

When installing the Hub 10 Telco in a stack with

FMS units, the Hub 10 Telco must be installed beneath any FMS

the top or bottom of the stack.

units.

free standing stacks:

the module must be fitted to an FMS unit at

the top of the stack.

When deciding where to site the Hub 10 Telco ensure:

It is accessible and cables can be connected easily.

Managing with a Hub 10 (FMS II) Management

Module (3C16630A) or Advanced RMON Module

Cabling is away from:

(3C16632)

sources of electrical noise such as radios, transmitters and

rack mounted stacks:

the module must be fitted to a Hub 10 (FMS II)

broadband amplifiers.

unit at the top or bottom of the stack.

power lines and fluorescent lighting fixtures.

free standing stacks:

the module must be fitted to a Hub 10 (FMS II)

Water or moisture cannot enter the case of the unit.

unit at the bottom of the stack.

Air flow around the unit and through the vents in the side of the

If you have a Hub 10, LinkBuilder FMS or FMS II unit fitted with a

Management Module, and a LinkBuilder 10BTi in your stack, the Hub 10,

case is not restricted (3Com recommend that you provide a

minimum of 25mm (1 inch) clearance).

FMS or FMSII Management Module will manage the stack.

To prolong the operational life of your units:

The LinkBuilder 10BTi can only manage LinkBuilder 10BT units

and the FMS Telco Hub (3C16271). 10BTi cannot manage other

Never stack units more than eight high if free standing.

FMS units or any Hub 10 (FMS II) units.

Do not place objects on top of any unit or stack.

Do not obstruct any vents at the sides of the case.

Power Up

Use the following sequence to power up the Hub 10 Telco:

Rack or Wall Mounting

Check the Disable On Boot switch at the rear and select position

The Hub 10 Telco can be mounted in a 19 inch equipment rack or else

as appropriatesee

wall-mounted using the LinkBuilder Rack Mounting Kit. See

Check the network connections and cables.

overleaf.

Check the hub expansion cables if in a stack.

Stacking Units

Connect the power supply cable to the appropriate power socket

The Hub 10 Telco can be linked to other Hub 10 units to form a stack, or

on the rear panel of the unit, see

can be part of a mixed stack consisting of Hub 10, FMS, FMS II, 10BT or

Connect the plug to the power supply outlet socket and switch

10BTi units.

on the power supply at the socket. If you are using a 3Com

Different rules apply on stacking units if the stack only consists of Hub

Redundant Power Supply make sure it is switched on.

10 and/or FMS II units compared to a stack with other mixed units.

When the Hub 10 Telco is powered up, the Power LED should be lit. If it

Hub 10/FMS II only stacks

is not, refer to

Up to 8 Hub 10 (FMS II) units can be linked together to form a free

Spot Checks

standing stack or be mounted in a 19 inch rack, in a managed or

unmanaged configuration.

At frequent intervals you should visually check the Hub10 Telco. Regular

checks can give you an early warning of a possible failure; any problems

Only fit a Hub 10 or LinkBuilder FMS II Management Module or

can then be attended to when there will be least effect on users. Check

Advanced RMON Module, to either the unit at the top or bottom of the

stack.

the following:

Check that all external cabling connections are

Mixed stacks of Hub 10/FMS II/FMS/10BT/10BTi

secure and that no cables are pulled taut.

Link up to 8 units in a free standing stack or mounted in a rack. But any

FMS, 10BT or 10BTi units must be units 1-4 in a managed stack.

Check that the cooling fans are operating and are

not obstructed. The fans are fitted to the right

If mixing Hub 10 (FMS II) and FMS units in a free standing stack, the

hand side of the unit when viewed from the front.

narrower FMS units must be positioned at the top of the stack. This

restriction does not apply if rack mounting the units.

Check that the Transceiver Module is connected

securely. Refer to the guide provided with the

Transceiver Module.

To manage any stack containing a Hub 10 unit, the Management

What To Do Next?

Module must have the correct version of the agent installed. The table

below details the minimum agent version numbers for each

If the Hub 10 Telco fails to operate successfully, contact your supplier

with the following information before returning the unit:

management module.

3C16030

LinkBuilder FMS Management Module

3C16630

LinkBuilder FMS II Management Module

3C16630A

SuperStack II (FMS II) Management Module

a brief description of the fault

3C16632

SuperStack II (FMS II) Advanced RMON Module

When returning any equipment to your supplier make sure the

equipment is packed suitably for transit.

Check which version you have installed before adding a Hub 10 unit to

your stack.

If you need to upgrade your agent, and a disk containing the new

versions is not included in the packaging, a free upgrade is available

from the 3Com bulletin boards (see

Products and Bulletin Boards

). The

upgrade includes instructions on how to load the agent.

Show 17 more labels / short text on this page
“ · Rack · Mounting Kit Instructions · ” · or · “ · Power LED · ” · , · Cabling · Cooling fans · Transceiver Module · Stack Management · product number · serial number · “ · ”
Page 7 of the 3Com II Hub 10 user manual —
Page 7 · click to enlarge
Page 7

P RODUCTS AND B ULLETIN B OARDS

Products

Bulletin Boards

SuperStack II Hub 10 is part of the SuperStack II range of 3Com

Management agent software upgrades are available from these 3Com

products. Contact your supplier for the latest product information.

bulletin boards:

(61) (2) 9955 2073

(81) (3) 3345 7266

3C16670A SuperStack II Hub 10 12Port TP

(33) (1) 69 86 69 54

3C16671A SuperStack II Hub 10 24Port TP

(49) (89) 627 32 188

(886) (2) 377 5838

3C16672A SuperStack II Hub 10 24Port Telco

or 627 32 189

3C16665A SuperStack II Hub 10 6Port ST Fiber Optic

U.K.

(39) (2) 273 00680

U.S.

(1) (408) 980 8204

3C16630A SuperStack II Hub10 Management Module

3C16632 SuperStack II Hub10 Advanced RMON Module

3Com Corporation P.O. Box 58145 5400 Bayfront Plaza Santa Clara CA 95052-8145 USA

c/o 3Com Centre Boundary Way Maylands Park South Hemel Hempstead Herts HP2 7YU UK

3C12065 Fiber Optic (ST)

3C12063 TP

3C12064 Fan Out (male AUI)

3C12067 FB

R ACK M OUNTING K IT I NSTRUCTIONS

To wall mount the Hub 10 unit(s):

The Hub 10 Telco is supplied with two mounting brackets and four

Ensure that the wall you are going to use is smooth, flat, dry and sturdy.

screws. These are used for rack mounting and wall mounting the unit.

Attach a piece of plywood (12" x 20" x 0.5") securely to the wall if

When mounting the unit, you should take note of the guidelines given

necessary, and mount the Hub 10 unit(s) as follows:

Siting the Hub 10 Telco

overleaf.

Position the unit(s) against the wall (or plywood) ensuring that

Wall Mounting Hub 10 Units

the ventilation holes face sideways. Mark on the wall the position

of the screws holes for both wall brackets. Drill the four holes.

Disconnect all cables from the Hub 10 unit(s) before

continuing. Remove the self-adhesive pads from underside of

Using suitable fixings and screws (not provided), attach the unit(s)

the unit(s), if already fitted.

securely to the wall (or plywood).

Fitting the brackets to wall mount one unit

Reconnect all cables.

Place the Hub 10 unit the right way up on a hard, flat surface with

Rack Mounting Hub 10 Units

the front facing towards you.

The Hub 10 Telco is 1U high and will fit a standard 19inch rack.

Locate a mounting bracket over the mounting holes on one side

Disconnect all cables from the Hub 10 unit before

of the unit, as shown in figure 1 below.

continuing. Remove the self-adhesive pads from underside of

Insert the two screws and fully tighten with a screwdriver.

unit, if already fitted.

Repeat the last two steps for the other side of the Hub 10 unit.

Place the unit the right way up on a hard, flat surface with the

Fitting the brackets to wall mount two units

front facing towards you.

Locate a mounting bracket over the mounting holes on one side

Stack the Hub 10 units the right way up on a hard, flat surface

of the unit, as shown in figure 3 below.

with the front facing towards you.

Insert the two screws and fully tighten with a suitable screwdriver.

Locate two mounting brackets over the mounting holes on one

side of the units, as shown in figure 2 below.

Repeat the two previous steps for the other side of the unit.

Insert the three screws and fully tighten with a screwdriver.

Insert the unit into the 19" rack and secure with suitable screws

(not provided).

Repeat the last two steps for the other side of the units.

Reconnect all cables.

3Com II Hub 10 —  diagram (page 7)
Fig. 5
Show 22 more labels / short text on this page
Australia · Japan · Hub 10 hubs · France · Singapore · (65) 534 5693 · Germany · Taiwan · Hong Kong · (852) 2537 5608 · (44) (1442) 438278 · Hub 10 management · Italy · (fee required) · Transceiver Modules · 3C12060 Female AUI · 3C12066 Coaxial · 3C16060 Bridge MicroModule · Introduction · in the section · “ · ”
Page 8 of the 3Com II Hub 10 user manual — UNITED STATES GOVERNMENT LEGENDS:
Page 8 · click to enlarge
Page 8

L IMITED W ARRANTY

For first five years - +5 Lifetime Limited Warranty

Center during the applicable warranty period. Standard warranty service for software

The SuperStack II Hub 10 Fiber benefits from 3Com’s enhanced +5 Lifetime Limited

products may be obtained by telephoning 3Com's Corporate Service Center or an

Warranty. This provides a full 5 years of advanced hardware exchange from your date of

Authorized 3Com Service Center, within the warranty period. Products returned to

purchase in accordance with 3Com’s standard terms and conditions. To qualify, you must

3Com's Corporate Service Center must be pre-authorized by 3Com with a Return

submit your warranty registration card to 3Com. After the initial 5 year period, the

Material Authorization (RMA) number marked on the outside of the package, and sent

warranty reverts to 3Com’s standard lifetime limited warranty. The +5 Lifetime Limited

prepaid, insured, and packaged appropriately for safe shipment. The repaired or replaced

Warranty is not offered or is void where restricted or prohibited by law.

item will be shipped to Customer, at 3Com's expense, not later than thirty (30) days after

receipt of the defective product by 3Com.

After first five years - Lifetime Limited Warranty

The duration of the 3Com standard lifetime limited warranty is lifetime, excluding the

Warranties Exclusive:

IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED

power supply and fans. See below for terms and conditions of this warranty.

ABOVE, CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR,

REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT 3COM'S OPTION. TO THE

Hardware:

3Com warrants its hardware products to be free from defects in workmanship

FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE

and materials, under normal use and service, for the following lengths of time from the

date of purchase from 3Com or its Authorized Reseller:

EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS,

EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR

Network adaptersLifetime Other Hardware productsOne year (unless otherwise specified above) Spare parts and spare kits90 days

OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE, AND SATISFACTORY QUALITY. 3COM NEITHER

ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER

LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS

If a product does not operate as warranted above during the applicable warranty period,

PRODUCTS.

3Com shall, at its option and expense, repair the defective product or part, deliver to

3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION

Customer an equivalent product or part to replace the defective item, or refund to

DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS

Customer the purchase price paid for the defective product. All products that are

CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER

replaced will become the property of 3Com. Replacement products may be new or

INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY

reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty or

OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,

the remainder of the initial warranty period, whichever is longer.

LIGHTNING, OR OTHER HAZARD.

3Com shall not be responsible for any software, firmware, information, or memory data

Limitation of Liability:

TO THE FULL EXTENT ALLOWED BY LAW 3COM ALSO EXCLUDES

of Customer contained in, stored on, or integrated with any products returned to 3Com

FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT

for repair, whether under warranty or not.

(INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR

PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF

Software:

3Com warrants that the software programs licensed from it will perform in

substantial conformance to the program specifications therefor for a period of ninety

BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF

(90) days from the date of purchase from 3Com or its Authorized Reseller. 3Com warrants

OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE,

FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED

the media containing software against failure during the warranty period. No updates

are provided. 3Com's sole obligation with respect to this express warranty shall be (at

RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS

3Com's discretion) to refund the purchase price paid by Customer for any defective

LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT

3COM'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED

software products, or to replace any defective media with software which substantially

conforms to 3Com's applicable published specifications. Customer assumes responsibility

IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.

for the selection of the appropriate applications program and associated reference

Some countries, states, or provinces do not allow the exclusion or limitation of implied

materials. 3Com makes no warranty or representation that its software products will

warranties or the limitation of incidental or consequential damages for certain products

work in combination with any hardware or applications software products provided by

supplied to consumers or the limitation of liability for personal injury, so the above

third parties, that the operation of the software products will be uninterrupted or error

limitations and exclusions may be limited in their application to you. This warranty gives

free, or that all defects in the software products will be corrected. For any third party

you specific legal rights which may vary depending on local law.

products listed in the 3Com software product documentation or specifications as being

compatible, 3Com will make reasonable efforts to provide compatibility, except where

Governing Law:

This Limited Warranty shall be governed by the laws of the state of

California.

the non-compatibility is caused by a "bug" or defect in the third party's product.

, 5400 Bayfront Plaza, Santa Clara, CA, 95052-8145, U.S.A.

Standard Warranty Service:

Standard warranty service for hardware products may be

obtained by delivering the defective product, accompanied by a copy of the dated proof

Tel(408) 764-5000 9/1/96

of purchase, to 3Com's Corporate Service Center or to an Authorized 3Com Service

E LECTRO - MAGNETIC C OMPATABILITY

This equipment has been tested and found to comply with the limits for a class A digital

This Class A digital apparatus meets all requirements of the Canadian

device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable

interference-Causing Equipment Regulations.

protection against interference when the equipment is operated in a commercial

environment. This equipment generates, uses and can radiate radio frequency energy

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le

matériel brouilleur du Canada.

and, if not installed and used in accordance with the instruction manual, may cause

harmful interference with radio communications. Operation of this equipment in a

residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.

L EGAL N OTICES

3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8145

For civilian agencies:

: Use, reproduction or disclosure is subject to restrictions as set

© 3Com Ireland, May 1996. All rights reserved. No part of this documentation may be

reproduced in any form or by any means or used to make any derivative work (such as

forth in subparagraph (a) through (d) of the Commercial Computer Software - Restricted

Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in 3Com Corporation's

translation, transformation, or adaptation) without permission from 3Com Ireland.

standard commercial agreement for the software. Unpublished rights reserved under the

3Com Ireland reserves the right to revise this documentation and to make changes in

copyright laws of the United States.

content from time to time without obligation on the part of 3Com Ireland to provide

notification of such revision or change.

Unless otherwise indicated, registered trademarks are registered in the United States and

may or may not be registered in other countries.

3Com Ireland provides this documentation without warranty of any kind, either implied

3Com and LinkBuilder are registered trademarks of 3Com Corporation. SuperStack II and

or expressed, including, but not limited to, the implied warranties of merchantability and

FMS are trademarks of 3Com Corporation. Other brand and product names may be

fitness for a particular purpose. 3Com may make improvements or changes in the

product(s) and/or the program(s) described in this documentation at any time.

registered trademarks or trademarks of their respective holders.

UNITED STATES GOVERNMENT LEGENDS:

The technology behind 3Com's LAN Security Architecture is protected by U.S. patents

5,161,192 and 5,386,470 (foreign patents applied for).

If you are a United States government agency, then this documentation and the

software described herein are provided to you subject to the following restricted rights:

For units of the Department of Defense:

Restricted Rights Legend:

Use, duplication or disclosure by the Government is subject to

restrictions as set forth in subparagraph (c) (1) (ii) for restricted Rights in Technical Data

Part NumberDUA1667-2AAA03

and Computer Software clause at 48 C.F.R. 52.227-7013. 3Com Ireland, c/o 3Com Centre,

Revision01

Boundary Way, Maylands Park South, Hemel Hempstead, Hertfordshire, HP2 7YU, UK.

PublishedDecember 1996
Show 4 more labels / short text on this page
3Com Corporation · FCC Statement · CSA Statement · Restricted Rights Legend

Ask about the 3Com II Hub 10

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the 3Com II Hub 10

Be the first to ask — other owners or our team will answer.

Original document

3Com II Hub 10 manual PDF

8 pages·505 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…