The Hub 10 Telco has been designed to conform to the following
Hub 10 Telco only
standards:
ISO 8802/3, IEEE 802.3
UL 1950, EN 60950, CSA 22.2 #950
22 VA
EMC
EN 55022 Class B, EN 50082-1, FCC Part 15 Class A,
CSA C108.8 Class A
(screened cables must be used to ensure
Hub 10 Telco & Management Module
compliance with these standards)
EN 60068 (IEC 68)
30 VA
440mm (17.3 ins)
224mm (8.8 ins)
44mm (1.7 ins) or 1U
2.6kg (5.7lb)
or 19" rack or wall mounted using kit supplied

Please read the following safety information carefully before
type, this unit should be powered by 230V (2P+T) via an isolation
installing the Hub 10 Telco.
transformer ratio 1:1, with the secondary connection point labelled
Neutral, connected directly to Earth (Ground).
Installation and removal of the unit must be
Impédance à la terre
Connect the unit to an earthed power supply to ensure
This must be approved for the country where it will be used.
compliance with safety standards.
The cord set must be UL-approved and CSA certified.
It is essential that the socket outlet is installed near to the unit
The minimum specifications for the flexible cord are:
and is easily accessible. You can only disconnect the unit by
No. 18 AWG
removing the supply plug from the outlet.
Type SV or SJ
This unit operates under SELV conditions (Safety Extra Low
Voltage) according to IEC 950, the conditions of which are
The cord set must have a rated current capacity of at
maintained only if the equipment to which it is connected is also
least 10A.
operational under SELV.
The attachment plug must be an earth-grounding
The appliance coupler, i.e., the connector to the device itself and
type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P
not the wall plug, must have a configuration for mating with an
(15A, 250V) configuration.
EN60320/IEC320 appliance inlet.
The supply plug must comply with Section 107-2-D1,
France and Peru Only
Standard DK2-1a or DK2-5a.
This unit cannot be powered from IT
supplies. If your supplies are of IT
The supply plug must comply with SEV/ASE 1011.
Veuillez lire à fond l'information de la sécurité suivante avant
Seulement Pour La France et Le Pérou
d'installer le Hub 10 Telco.
Cette unité ne peut pas être mise en marche des sources de courant IT
(Impédance à la terre). Si vos sources de courant sont de type IT, cette
L'installation et l'enlèvement de l'unité
unité doit être alimentée par 230V (2P+T) via un rapport de
doivent être faits seulement par le personnel qualifié.
transformation d'isolation de 1:1, avec un point de connexion secondaire
Brancher l'unité à une source de courant mise à la terre pour
étiqueté Neutre, branché directement à la Terre (à la Masse).
assurer la conformité aux normes de sécurité.
La Cordon d'Alimentation Surmoulé
Celui-ci doit être approuvé pour le pays auquel il sera utilisé.
C'est essentiel que le socle soit installé près de l'unité et soit
accessible. Vous pouvez seulement débrancher l'unité en
Le cordon surmoulé doit être UL Certifié et CSA Certifié.
enlevant la fiche d'alimentation de la prise de courant.
Les spécifications minimales pour le cordon souple sont:
Canada:
Cette unité marche sous les conditions SELV (Safety Extra Low
No. 18 AWG
Type 5V ou SJ
Voltage) conformément à IEC950, ces conditions sont maintenues
seulement si le matériel auquel elle est branchée, est aussi en
exploitation sous SELV.
Le cordon surmoulé doit avoir une capacité de courant
calculée au moins de 10A.
Le socle de connecteur, c'est-à-dire, le connecteur à l'appareil
La fiche de fixation doit être un type mis à la terre avec
lui-même et non pas la prise murale, doit avoir une configuration
pour le branchement avec une admission d'appareil
une configuration NEMA 5-15P (15A, 125V) ou NEMA
6-15P (15A, 250V).
EN60320/IEC320.
Bitte unbedingt vor dem Einbauen des Hub 10 Telco Einheit die
Herausziehen des Verbindungssteckers aus der Steckdose vom
folgenden Sicherheitsanweisungen durchlesen.
Stromnetz getrennt werden.
Ein- und Ausbau des Gerätes ist
Das Gerät wird mit Sicherheits-Kleinspannung nach IEC 950 (SELV
vorzunehmen.
= Safety Extra Low Voltage) betrieben. Angeschloßen werden
nnen nur Geräte, die ebenfalls nach SELV betrieben werden.
Das Gerät an geerdete Stromversorgung anschließen, um eine
Übereinstimmung mit den Sicherheitsbestimmungen zu
Die Anordnung der Gerätsteckvorrichtung, d.h. die
gewährleisten.
Steckverbindung am Gerät selbst im Gegensatz zum Wandstecker,
muß in den EN60320/IEC320 Zuführungsstecker am Gerät passen.
Es ist wichtig, daß der Netzstecker sich in unmittelbarer Nähe zum
Gerät befindet und leicht erreichbar ist. Das Gerät kann nur durch
Der Anschlußkabelsatz muß mit den Bestimmungen des Landes
übereinstimmen, in dem er verwendet werden soll.

The SuperStack™ II Hub 10 Telco (3C16672A) has two 12 port Telco
unit will be disabled during power-up until they are correctly configured
connectors on the front panel providing Ethernet TP port connections,
and enabled by management software. This is only necessary on units
and an AUI port on the rear panel. The rear panel also has a slot for a
which have ports assigned as standby. Standby ports in resilient link
3Com Transceiver Module or Bridge MicroModule: if fitted the module
pairs can only be configured on SuperStack II Hub 10 or LinkBuilder
will operate in addition to the AUI port. A range of different media
FMS II units.
Transceiver Modules is available from 3Com (see
Security features are described in the manual which comes with your
).
Hub 10 Management Module.
The Hub 10 Telco can be stand-alone or linked with other Hub 10,
By disabling ports on boot up and enabling them with management
LinkBuilder FMS II, FMS, 10BT or 10BTi units to form a stack of units of
software, you provide extra security for your unit.
different media. Stacking units gives you the benefit of a higher port
count while the stack is still seen by the network as a single 802.3
During the power up sequence, the main ports (on the front
repeater.
panel) will be disabled, BUT the AUI and Transceiver Module
ports will be enabled for periods up to 1 second. During this
The Hub 10 Telco is suited for use in the office where it can be
wall-mounted, rack-mounted, or free standing. Alternatively, the unit can
brief moment, the AUI and Transceiver Module ports will NOT
be rack-mounted in a wiring closet or equipment room. A mounting kit
be secure.
is supplied.
The Hub 10 Telco can be powered either from the AC mains supply, or
The Hub 10 Telco has been designed for use with the majority of known
through an optional 3Com Redundant Power System (3C565047) to
Telco connectors.
provide a more reliable supply. Contact your local supplier for details.
Cable fixings have been supplied for holding the Telco cables to the
unit. There are locations for these fixings to the left of the Telco
The Hub 10 Telco has been designed to conform to the IEEE 802.3
connectors.
standard for Local Area Networks. The unit provides all the standard
In the unlikely event that your Telco connector will not connect fully to
functions of an 802.3 repeater, including:
the Hub 10 Telco, we recommend that you:
Use a connector extension
Use a Telco connector with a different cable approach
You can connect any 802.3 transceiver to the unit using an AUI cable
connected to the AUI port on the rear panel. Alternatively, you can fit
one of the 3Com Transceiver Modules or a Bridge MicroModule into the
slot on the rear panel (see
Products and Bulletin Boards
).
A SuperStack II Hub 10 Management Module (3C16630A) or Advanced
You can connect the Hub 10 Telco to any other 10Base-T unit using port
RMON Module (3C16632) can be fitted to the Hub 10 Telco to provide
24, to form an inter-repeater link. You must switch port 24 to MDI to
, including statistics, resilient links and security
bypass the internal cross-over normally implemented by 10Base-T unit
. Only one Management Module or Advanced RMON Module is
ports. See
required for each stack. Refer to the guides accompanying the module
for details on how to manage an Hub 10 unit or stack.
ub 10 Management Module (3C16630A) and Hub 10 Advanced RMON
To manage this hub, you
ersion of the agent
Module (3C16632) offer resilience
eatures.
our Management Module.
Up to 16 resilient link pairs can be configured via management software.
for details.
To avoid the creation of loops during power-up, Hub 10 units provide a
Disable On Boot switch. If this switch is set to disable, all TP ports on the

Numbered elements in this diagram refer to numbered sections in the text.
The numbers, in bold, are used as references in the text.

The Transceiver Module port may partition if the SQE test pulse is
enabled on its transceiver. SQE test should be disabled on transceivers
used to connect 802.3 repeaters to the network.
A range of Telco connectors can be used with the Hub 10 Telco. Refer to
for more information.
The AUI LED lights red if the AUI port has partitioned. Refer to
Do not over-tighten the screws on the Telco
, for information on what to do if a segment is partitioned.
connectors.
An AUI port connected to coaxial cable segment may partition
if the segment is incorrectly terminated.
The Media Dependent Interface (MDI) switch controls the operation of
The AUI port may partition if the SQE test pulse is enabled on its
transceiver. SQE test should be disabled on transceivers used to connect
port 24. The switch is recessed and can be operated using a ball-point
pen or similar instrument.
802.3 repeaters to the network.
In this position you can connect port 24 to a
workstation or any other DTE.
The UNIT LEDs indicate the position of this unit in the stack, providing a
In this position you can connect port 24 to any
Management Module or Advanced RMON Module has been fitted to a
internal cross-over (X) port on another 10Base-T
unit in the stack. The appropriate UNIT LED will light green; if this unit
has a Management Module (or Advanced RMON Module) fitted, it will
repeater using normal twisted pair cable to form an
show as unit number 1. If the unit is in a stack which does not contain a
inter-repeater link.
Management Module or Advanced RMON Module, the UNIT LEDs will
not light.
To form an inter-repeater link using two Hub 10 Telcos, connect port 24
on unit 1 to any port on unit 2. Ensure that the MDI switch on unit 1 is
IN (MDI) and that if port 24 is used on unit 2, the MDI switch is OUT
(MDIX).
The Power LED lights green to indicate the power supply to the unit is
correct. If it is not lit, and:
The STATUS LEDs show the partition state of a port and whether or not
None of the ports work
Check the fuse in the IEC socket and the
fuse within the power cable's plug (if
the Link Pulse signal is present on the segment connected to a port
fitted).
The Link Pulse signal is being received and the segment
The AUI and Transceiver
The internal fixed fuse for the power
attached to the port is functional.
If the port does not
Module ports do not work,
supply to the AUI and Transceiver
transmit/receive, check the Disable On Boot switch, 15, is
but the twisted pair ports
Module ports has blown. Contact your
Enabled.
supplier.
The Link Pulse signal is being received and the port is
All ports function normally
The LED has failed. Contact your supplier.
partitioned from the network.
Check the connections and the cable for any breaks in the
segment.
The MGMT LED indicates the status of the Management Module or
Advanced RMON Module if fitted.
Make sure the transceiver attached to the DTE is correctly
connected and powered up.
There is no Management Module or Advanced RMON
Check for illegal 802.3 configurations, in particular, loops.
Module fitted to the Hub 10 Telco or the internal
Check that the Disable On Boot switch,
, is set for units
connection to it has been broken.
with standby ports in resilient links.
The Management Module (or Advanced RMON
If the cause of the partition is found and corrected, the segment
Module) is fitted and functioning normally.
is reconnected automatically, after the first valid packet is
Management agent software is being downloaded.
transmitted to, or received from the segment.
There is a fault on the Management Module (or
The Link Pulse signal is not being received.
Advanced RMON Module) or one of the units in the
stack. Check all connections and refer to the
Check that the attached DTE is switched on.
Management Module guide for more information.
Check that the Link Pulse signal has not been disabled by
management software.
Check that the attached transceiver is not faulty.
The Packet LED flashes yellow whenever a packet is received on one of
the 12 twisted pair ports, the AUI port, or the Transceiver Module port.
If it is an inter-repeater link, check the setting of the MDI
switch.
If this LED does not flash, there are no packets being received by the
unit.
Carry out the checks recommended for when a STATUS LED
is red.
Check for no more than 4 repeater stacks in series, and that
The Collision LED flashes yellow when a packet collision has been
cable lengths do not exceed the maximum specified in the
detected on a segment connected to one of the 24 Telco ports, the AUI
standard for that medium.
port, or the Transceiver Module port.
If these checks do not identify the cause of a problem, it may be that the
Under normal 802.3 operation, collisions occur and cause the Collision
Hub 10 Telco or the device connected to the port is faulty. Contact your
LED to flash. The probability of collisions increases during heavy activity
supplier for further advice.
on the network. The Auto Partition/Reconnection function partitions a
segment from the rest of the network if more than 64 consecutive
collisions are detected on that segment.
The TCVR LED lights red if the Transceiver Module port has partitioned.
for information on what to do if a segment is
partitioned.
A transceiver module port connected to coaxial cable segment
may partition if the segment is incorrectly terminated.

You can connect units together in a stack to form a single logical
Power Supply and Fuse
repeater. You need one Hub Expansion Cable (3C625) for each additional

Correct fuse location L’emplacement du fusible correct Richtige Stellung der Sicherung
unit in the stack. The diagram below shows how you connect units
together. Do not use two cables to connect any two units to each other
- they will not work if you do this.
Spare fuse location - DO NOT USE L’emplacement du fusible incorrect - NE PAS UTILISER Falsche Stellung der Sicherung - NICHT VERWENDEN
Disconnect power from all units that will form part of the new
stack.
Connect the male hub expansion connector of one unit to the
female hub expansion connector of the next unit. Repeat this process
until all the units are connected together. Refer to
the number of units allowed in a stack.
The Hub 10 Telco automatically adjusts to the supply voltage.
If you intend to rack or wall mount the units,
The fuse is suitable for both 110V A.C. and 220-240V A.C.
connect the units after they have been mounted.
operation.
Disable On Boot Switch
To change the fuse, release the fuse holder by gently levering a
small screwdriver under the fuse holder catch. Only 2A
This switch is located behind the blanking plate covering the
anti-surge type fuses of the same type and manufacture as the
. The unit is shipped with this switch set to
Enable.
original should be used with the Hub 10 Telco. Close the fuse

holder.
Assurer que l'alimentation soit débranchée
avant d'ouvrir le couvercle du contenant du fusible.
L'unité s'ajuste automatiquement à la tension d'alimentation.
Le fusible est convenable aux deux opérations 110 V C.A. et
220-240 V C.A.
Pour changer le fusible, dégager le contenant du fusible en
mettant doucement un petit tournevis sous l'arrêt de
contenant du fusible. Seulement les fusibles de types 2A
Management / Advanced RMON Module Power Cable
anti-transitoires du même type et fabricant que l'original
doivent être utilisés.
This plug, located behind the blanking plate, provides power to an Hub
Vor dem Öffnen der Sicherungshalterung das Gerät
10 Management Module or Advanced RMON Module, if fitted and
vom Netzstrom trennen.
connected. See the guide accompanying the module for installation
instructions.
Das Gerät stellt sich automatisch auf die
Versorgungsspannung ein. Die Sicherung ist sowohl für 110V
A.C. wie für 220-240V A.C. geeignet.
You can connect the unit to any 802.3 transceiver using an AUI cable
(sometimes known as a transceiver cable or drop cable). Connect one
Zum Auswechseln der Sicherung durch leichtes Heben mit
end of the AUI cable to the AUI port on the rear panel of the unit and
einem kleinen Schraubenzieher die Abdeckungsklappe der
the other end to the AUI port on the transceiver. Engage the slide locks
Sicherungshalterung lösen. Sicherungen nur durch gleichen
at both ends of the AUI cable.
Typ und Wert wie die Originalsicherung ersetzen. Sicherung
auswechseln und die Klappe der Sicherungshalterung wieder
Ensure that SQE test is disabled.
schließen.
Socket for Redundant Power System
A variety of 3Com plug-in Transceiver Modules or the Bridge
MicroModule can be installed in the Hub 10 Telco (see overleaf
for a list).
Only connect a 3Com Redundant Power System, option 3C565047, to
Transceivers provide direct network connections to different media.
this socket. For details, follow the installation instructions in the guide
accompanying the Redundant Power System.
Do not remove the Transceiver Module blanking
plate with the power still connected.
Management Module or Advanced RMON Module Slot
Ensure that SQE test is disabled.
The Hub 10 Telco can be fitted with an optional SuperStack II Hub 10
Management Module or Advanced RMON Module. When the module
To install a Transceiver Module, refer to the guide that accompanies it. If
has an IP/IPX address, you can then use SNMP management to manage
you subsequently remove the Transceiver Module, you must replace the
the stack containing the unit.
blanking plate to aid the circulation of cooling air and prevent the entry
of dust and debris.
Do not remove the Management Module blanking
plate with the power still connected.
For instructions on installing either module in an Hub 10 unit, refer to
The Hub 10 Telco is supplied with 4 self-adhesive rubber pads. If the unit
the guide that accompanies the module. You will need to remove the
is to be part of a free standing stack, apply the pads to the underside of
blanking plate to reveal the slot for the module.
the unit; stick a pad in the marked area at each corner of the unit. Place
the units on top of each other, ensuring that the pads of the upper unit
If you subsequently remove the Management or Advanced RMON
locate with the recesses of the lower unit.
Module from the Hub 10 unit, you must replace the blanking plate to aid
Do not apply the pads if you intend to rack or wall mount the unit.
the circulation of cooling air and prevent the entry of dust and debris.

Managing with an FMS Management Module
rack mounted stacks:
the module must be fitted to an FMS unit at
When installing the Hub 10 Telco in a stack with
FMS units, the Hub 10 Telco must be installed beneath any FMS
the top or bottom of the stack.
units.
free standing stacks:
the module must be fitted to an FMS unit at
the top of the stack.
When deciding where to site the Hub 10 Telco ensure:
It is accessible and cables can be connected easily.
Managing with a Hub 10 (FMS II) Management
Module (3C16630A) or Advanced RMON Module
Cabling is away from:
sources of electrical noise such as radios, transmitters and
rack mounted stacks:
the module must be fitted to a Hub 10 (FMS II)
broadband amplifiers.
unit at the top or bottom of the stack.
power lines and fluorescent lighting fixtures.
free standing stacks:
the module must be fitted to a Hub 10 (FMS II)
Water or moisture cannot enter the case of the unit.
unit at the bottom of the stack.
Air flow around the unit and through the vents in the side of the
If you have a Hub 10, LinkBuilder FMS or FMS II unit fitted with a
Management Module, and a LinkBuilder 10BTi in your stack, the Hub 10,
case is not restricted (3Com recommend that you provide a
minimum of 25mm (1 inch) clearance).
FMS or FMSII Management Module will manage the stack.
To prolong the operational life of your units:
The LinkBuilder 10BTi can only manage LinkBuilder 10BT units
and the FMS Telco Hub (3C16271). 10BTi cannot manage other
Never stack units more than eight high if free standing.
FMS units or any Hub 10 (FMS II) units.
Do not place objects on top of any unit or stack.
Do not obstruct any vents at the sides of the case.
Use the following sequence to power up the Hub 10 Telco:
Check the Disable On Boot switch at the rear and select position
The Hub 10 Telco can be mounted in a 19 inch equipment rack or else
wall-mounted using the LinkBuilder Rack Mounting Kit. See
Check the network connections and cables.
overleaf.
Check the hub expansion cables if in a stack.
Connect the power supply cable to the appropriate power socket
The Hub 10 Telco can be linked to other Hub 10 units to form a stack, or
on the rear panel of the unit, see
can be part of a mixed stack consisting of Hub 10, FMS, FMS II, 10BT or
Connect the plug to the power supply outlet socket and switch
10BTi units.
on the power supply at the socket. If you are using a 3Com
Different rules apply on stacking units if the stack only consists of Hub
Redundant Power Supply make sure it is switched on.
10 and/or FMS II units compared to a stack with other mixed units.
When the Hub 10 Telco is powered up, the Power LED should be lit. If it
Hub 10/FMS II only stacks
is not, refer to
Up to 8 Hub 10 (FMS II) units can be linked together to form a free
standing stack or be mounted in a 19 inch rack, in a managed or
unmanaged configuration.
At frequent intervals you should visually check the Hub10 Telco. Regular
checks can give you an early warning of a possible failure; any problems
Only fit a Hub 10 or LinkBuilder FMS II Management Module or
can then be attended to when there will be least effect on users. Check
Advanced RMON Module, to either the unit at the top or bottom of the
stack.
the following:
Check that all external cabling connections are
Mixed stacks of Hub 10/FMS II/FMS/10BT/10BTi
secure and that no cables are pulled taut.
Link up to 8 units in a free standing stack or mounted in a rack. But any
FMS, 10BT or 10BTi units must be units 1-4 in a managed stack.
Check that the cooling fans are operating and are
not obstructed. The fans are fitted to the right
If mixing Hub 10 (FMS II) and FMS units in a free standing stack, the
hand side of the unit when viewed from the front.
narrower FMS units must be positioned at the top of the stack. This
restriction does not apply if rack mounting the units.
Check that the Transceiver Module is connected
securely. Refer to the guide provided with the
Transceiver Module.
To manage any stack containing a Hub 10 unit, the Management
Module must have the correct version of the agent installed. The table
below details the minimum agent version numbers for each
If the Hub 10 Telco fails to operate successfully, contact your supplier
with the following information before returning the unit:
management module.
LinkBuilder FMS Management Module
LinkBuilder FMS II Management Module
SuperStack II (FMS II) Management Module
a brief description of the fault
SuperStack II (FMS II) Advanced RMON Module
When returning any equipment to your supplier make sure the
equipment is packed suitably for transit.
Check which version you have installed before adding a Hub 10 unit to
your stack.
If you need to upgrade your agent, and a disk containing the new
versions is not included in the packaging, a free upgrade is available
from the 3Com bulletin boards (see
Products and Bulletin Boards
). The
upgrade includes instructions on how to load the agent.

Bulletin Boards
SuperStack II Hub 10 is part of the SuperStack II range of 3Com
Management agent software upgrades are available from these 3Com
products. Contact your supplier for the latest product information.
bulletin boards:
(61) (2) 9955 2073
(81) (3) 3345 7266
3C16670A SuperStack II Hub 10 12Port TP
(33) (1) 69 86 69 54
3C16671A SuperStack II Hub 10 24Port TP
(49) (89) 627 32 188
(886) (2) 377 5838
3C16672A SuperStack II Hub 10 24Port Telco
or 627 32 189
3C16665A SuperStack II Hub 10 6Port ST Fiber Optic
U.K.
(39) (2) 273 00680
U.S.
(1) (408) 980 8204
3C16630A SuperStack II Hub10 Management Module
3C16632 SuperStack II Hub10 Advanced RMON Module
3Com Corporation P.O. Box 58145 5400 Bayfront Plaza Santa Clara CA 95052-8145 USA
c/o 3Com Centre Boundary Way Maylands Park South Hemel Hempstead Herts HP2 7YU UK
3C12065 Fiber Optic (ST)
3C12064 Fan Out (male AUI)
R ACK M OUNTING K IT I NSTRUCTIONS
To wall mount the Hub 10 unit(s):
The Hub 10 Telco is supplied with two mounting brackets and four
Ensure that the wall you are going to use is smooth, flat, dry and sturdy.
screws. These are used for rack mounting and wall mounting the unit.
Attach a piece of plywood (12" x 20" x 0.5") securely to the wall if
When mounting the unit, you should take note of the guidelines given
necessary, and mount the Hub 10 unit(s) as follows:
Siting the Hub 10 Telco
overleaf.
Position the unit(s) against the wall (or plywood) ensuring that
Wall Mounting Hub 10 Units
the ventilation holes face sideways. Mark on the wall the position
of the screws holes for both wall brackets. Drill the four holes.
Disconnect all cables from the Hub 10 unit(s) before
continuing. Remove the self-adhesive pads from underside of
Using suitable fixings and screws (not provided), attach the unit(s)
the unit(s), if already fitted.
securely to the wall (or plywood).
Fitting the brackets to wall mount one unit
Reconnect all cables.
Place the Hub 10 unit the right way up on a hard, flat surface with
Rack Mounting Hub 10 Units
the front facing towards you.
The Hub 10 Telco is 1U high and will fit a standard 19inch rack.
Locate a mounting bracket over the mounting holes on one side
Disconnect all cables from the Hub 10 unit before
of the unit, as shown in figure 1 below.
continuing. Remove the self-adhesive pads from underside of
Insert the two screws and fully tighten with a screwdriver.
unit, if already fitted.
Repeat the last two steps for the other side of the Hub 10 unit.
Place the unit the right way up on a hard, flat surface with the
Fitting the brackets to wall mount two units
front facing towards you.
Locate a mounting bracket over the mounting holes on one side
Stack the Hub 10 units the right way up on a hard, flat surface
of the unit, as shown in figure 3 below.
with the front facing towards you.
Insert the two screws and fully tighten with a suitable screwdriver.
Locate two mounting brackets over the mounting holes on one
side of the units, as shown in figure 2 below.
Repeat the two previous steps for the other side of the unit.
Insert the three screws and fully tighten with a screwdriver.
Insert the unit into the 19" rack and secure with suitable screws
(not provided).
Repeat the last two steps for the other side of the units.
Reconnect all cables.


For first five years - +5 Lifetime Limited Warranty
Center during the applicable warranty period. Standard warranty service for software
The SuperStack II Hub 10 Fiber benefits from 3Com’s enhanced +5 Lifetime Limited
products may be obtained by telephoning 3Com's Corporate Service Center or an
Warranty. This provides a full 5 years of advanced hardware exchange from your date of
Authorized 3Com Service Center, within the warranty period. Products returned to
purchase in accordance with 3Com’s standard terms and conditions. To qualify, you must
3Com's Corporate Service Center must be pre-authorized by 3Com with a Return
submit your warranty registration card to 3Com. After the initial 5 year period, the
Material Authorization (RMA) number marked on the outside of the package, and sent
warranty reverts to 3Com’s standard lifetime limited warranty. The +5 Lifetime Limited
prepaid, insured, and packaged appropriately for safe shipment. The repaired or replaced
Warranty is not offered or is void where restricted or prohibited by law.
item will be shipped to Customer, at 3Com's expense, not later than thirty (30) days after
receipt of the defective product by 3Com.
After first five years - Lifetime Limited Warranty
The duration of the 3Com standard lifetime limited warranty is lifetime, excluding the
Warranties Exclusive:
IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED
power supply and fans. See below for terms and conditions of this warranty.
ABOVE, CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR,
REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT 3COM'S OPTION. TO THE
Hardware:
3Com warrants its hardware products to be free from defects in workmanship
FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE
and materials, under normal use and service, for the following lengths of time from the
date of purchase from 3Com or its Authorized Reseller:
EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS,
EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR
FITNESS FOR A PARTICULAR PURPOSE, AND SATISFACTORY QUALITY. 3COM NEITHER
ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER
LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS
If a product does not operate as warranted above during the applicable warranty period,
PRODUCTS.
3Com shall, at its option and expense, repair the defective product or part, deliver to
3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION
Customer an equivalent product or part to replace the defective item, or refund to
DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS
Customer the purchase price paid for the defective product. All products that are
CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER
replaced will become the property of 3Com. Replacement products may be new or
INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY
reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty or
OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,
the remainder of the initial warranty period, whichever is longer.
LIGHTNING, OR OTHER HAZARD.
3Com shall not be responsible for any software, firmware, information, or memory data
Limitation of Liability:
TO THE FULL EXTENT ALLOWED BY LAW 3COM ALSO EXCLUDES
of Customer contained in, stored on, or integrated with any products returned to 3Com
FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT
for repair, whether under warranty or not.
PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF
Software:
3Com warrants that the software programs licensed from it will perform in
substantial conformance to the program specifications therefor for a period of ninety
BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF
(90) days from the date of purchase from 3Com or its Authorized Reseller. 3Com warrants
OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE,
FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED
the media containing software against failure during the warranty period. No updates
are provided. 3Com's sole obligation with respect to this express warranty shall be (at
RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS
3Com's discretion) to refund the purchase price paid by Customer for any defective
LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT
3COM'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED
software products, or to replace any defective media with software which substantially
conforms to 3Com's applicable published specifications. Customer assumes responsibility
IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
for the selection of the appropriate applications program and associated reference
Some countries, states, or provinces do not allow the exclusion or limitation of implied
materials. 3Com makes no warranty or representation that its software products will
warranties or the limitation of incidental or consequential damages for certain products
work in combination with any hardware or applications software products provided by
supplied to consumers or the limitation of liability for personal injury, so the above
third parties, that the operation of the software products will be uninterrupted or error
limitations and exclusions may be limited in their application to you. This warranty gives
free, or that all defects in the software products will be corrected. For any third party
you specific legal rights which may vary depending on local law.
products listed in the 3Com software product documentation or specifications as being
compatible, 3Com will make reasonable efforts to provide compatibility, except where
Governing Law:
This Limited Warranty shall be governed by the laws of the state of
California.
the non-compatibility is caused by a "bug" or defect in the third party's product.
, 5400 Bayfront Plaza, Santa Clara, CA, 95052-8145, U.S.A.
Standard Warranty Service:
Standard warranty service for hardware products may be
obtained by delivering the defective product, accompanied by a copy of the dated proof
of purchase, to 3Com's Corporate Service Center or to an Authorized 3Com Service
This equipment has been tested and found to comply with the limits for a class A digital
This Class A digital apparatus meets all requirements of the Canadian
device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable
interference-Causing Equipment Regulations.
protection against interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le
matériel brouilleur du Canada.
and, if not installed and used in accordance with the instruction manual, may cause
harmful interference with radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8145
For civilian agencies:
: Use, reproduction or disclosure is subject to restrictions as set
© 3Com Ireland, May 1996. All rights reserved. No part of this documentation may be
reproduced in any form or by any means or used to make any derivative work (such as
forth in subparagraph (a) through (d) of the Commercial Computer Software - Restricted
Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in 3Com Corporation's
translation, transformation, or adaptation) without permission from 3Com Ireland.
standard commercial agreement for the software. Unpublished rights reserved under the
3Com Ireland reserves the right to revise this documentation and to make changes in
copyright laws of the United States.
content from time to time without obligation on the part of 3Com Ireland to provide
notification of such revision or change.
Unless otherwise indicated, registered trademarks are registered in the United States and
may or may not be registered in other countries.
3Com Ireland provides this documentation without warranty of any kind, either implied
3Com and LinkBuilder are registered trademarks of 3Com Corporation. SuperStack II and
or expressed, including, but not limited to, the implied warranties of merchantability and
FMS are trademarks of 3Com Corporation. Other brand and product names may be
fitness for a particular purpose. 3Com may make improvements or changes in the
product(s) and/or the program(s) described in this documentation at any time.
registered trademarks or trademarks of their respective holders.
The technology behind 3Com's LAN Security Architecture is protected by U.S. patents
5,161,192 and 5,386,470 (foreign patents applied for).
If you are a United States government agency, then this documentation and the
software described herein are provided to you subject to the following restricted rights:
For units of the Department of Defense:
Restricted Rights Legend:
Use, duplication or disclosure by the Government is subject to
restrictions as set forth in subparagraph (c) (1) (ii) for restricted Rights in Technical Data
and Computer Software clause at 48 C.F.R. 52.227-7013. 3Com Ireland, c/o 3Com Centre,
Boundary Way, Maylands Park South, Hemel Hempstead, Hertfordshire, HP2 7YU, UK.