We thank you for choosing a SAEY stove! A SAEY is for life. So, rest assured, and put your trust in many years’ craftsmanship. Enjoy it to the full and discover how heart-warming a SAEY stove can be. Hour after hour. Year after year. This manual contains indispensable instructions for a professional installation. It also includes directions and suggestions for the proper use of the appliance. Please read it carefully and keep it throughout the product’s life.
You SAEY stove enjoys a two-year warranty covering possible construction errors. This applies from the purchase date onwards and to the extent that the usage is in accordance with the installation and operation instructions. Your receipt or invoice with listed date of purchase will apply as your warranty certificate. This warranty is restricted to the repair or replacement of those parts which present faults during normal usage. This warranty will not stand for faults that result from bad installation, wrong usage, modifications to the appliance, disassembling the appliance, wear or lack of maintenance. Warranty requests need to be made via your point of sale.
The packaging of your new stove offers exceptional protection against damage. However the product and its accessories can be damaged during transport. So please check the stove for damage and missing components when it’s delivered. Notify your dealer immediately of any missing components. The packaging includes : 1 stove 1 universal operating handle 1 coal poker 1 thermostat knob 2 heat resistant gloves 1 manual The packaging of your product is harmless for the environment. The cardboard and wood can be returned to the local waste recycling centre.

The following safety regulations must be complied with: Read the manual carefully prior to installation and use. When fuel is burning heat is released, so the top, the doors, the door handles and the flues may become very hot. These parts may not be touched without suitable heat resistant gloves or the operating handle. Inform your children about this danger and make sure that they stay at a safe distance when the stove is in use. Do not place combustible objects in the neighbourhood of the fire. Do not put a kettle on top of the stove. Do not put clothes on the stove to dry. Drying racks for clothes, etc. must be placed at a safe distance from the appliance – fire risk! During use no flammable or explosive materials may be used in the same or adjacent spaces, The stove is not designed as an all-purpose incinerator. Use only recommended fuels. The insert may not be altered or modified in any way. Use only original spare parts from the manufacturer. This stove is not suited for installation using a flue to which multiple stoves are connected.


Minimum – maximum heat output kW 5 – 14 5 – 14
T° flue gasses at nominal heat output* °C 334 334
Distance middle flue outlet – floor mm 557 557
Chimney draught at nominal heat output Pa 12 12
Recommended chimney draught Pa 8 - 20 8 - 20
Fuel consumption at nominal heat output kg 1,54 1,54
Recommended multicaliber mm 20 / 30 20 / 30
wood wood bricks Fuel consumption at nominal heat output kg/h 2,64 2,64
Fuel consumption at maximal heat output kg/h 4,20 4,20
Maximum diameter mm 300 300 * based on wood

6 INSTALLATION All local regulations, including those referring to national and European standards need to be complied with when installing the appliance. Only an appliance connected by a qualified installer guarantees compliance with legislation on construction and fire prevention. This is certainly required for safe and proper use of the stove.
The appliance shall be erected on floors with an adequate loadbearing capacity (see technical data). If an existing construction doesn’t meet this prerequisite, suitable measures shall be taken to achieve it. Install the appliance as much at level as possible. If the stove is installed on an inflammable floor, then place a fireproof plate underneath the appliance. Make sure to respect the following safety clearance distances from combustible materials: Frontwards 80cm Backwards 40cm Sideways 64cm
The required oxygen for the fire is supplied through inlets in the front and the backside of the stove. An optimal combustion requires sufficient fresh air. A lack of oxygen may result in incomplete combustion and reversing flue gases.



Additional combustion air can be supplied by placing an air inlet grill as close as possible to the appliance. Air inlet grills must be positioned so that they are not liable to blockage.

We guarantee the proper functioning of the appliance if the chimney draught is between 8 and 20 Pa. If the chimney draught is too high, then a damper must be incorporated. If there isn’t enough chimney draught, then the following measures can be considered: Extending the chimney Improving the insulation of the chimney (less cooling of the flue gases) Increasing the supply of combustion air into the space in which the appliance is installed. Improving the airtightness of the chimney
Many problems with inset fires are caused by badly working chimneys. Therefore some suggestions: A round channel is preferred (minimum friction) The diameter of the chimney may not be smaller at any point than that of the appliance (except in very long chimneys where a narrower section should sometimes be included) The mouth of the chimney should be unobstructed The chimney should be as close as possible to vertical with as few curves as possible. The chimney must not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar or on the roof! The chimney may not have too many connections - that reduces the upwards pressure. Consult your chimney specialist! Flue connections to different stoves and fireplaces may not be located opposite each other at the same height, in order to prevent the chance that combustion gases will not be drawn out. Two flue connections must be at separated vertically by at least 30 cm. For the chimney opening, you will need to comply with your national legislation. For details on chimneys we refer you to the relevant regulations with which the chimney needs to comply.

The stove can be connected directly to the chimney.



The diameter of the chimney should match the diameter of the flue outlet of the appliance., Please note the following regarding the diameter of the chimney: The diameter of the chimney may not be reduced. Also, the flue outlet must fit the chimney perfectly. If there is too much chimney draught, then a damper must be incorporated. The chimney may not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar or on the roof! The flue outlet must be securely attached to the connector pipe.
We recommend that you take the following steps in the event of a chimney fire 1. Close off the air supply. 2. Call the fire brigade. 3. Clear access routes to the cleaning openings (e.g. cellar and attic). 4. Move all inflammable objects away from the chimney. 5. When the appliance is put back into service, the chimney and the stove should be checked over by a specialist. 6. This specialist should also investigate the cause of the chimney fire after and take any corrective measures. SUGGESTION If you let the fire burn for 10 minutes each day at maximum power, this allows combustion products to be burnt off. This reduces the risk of any chimney fire and also helps keep the window cleaner.

Fuel Clean, dry firewood Only cleaved firewood with a moisture content of ≤20% is suited for use in this appliance. Hard wood types such as oak, birch, beech or wood fruit trees are preferred. You may also burn wood briquettes. It’s also important to use the correct length and an appropriate amount of firewood. Damp wood results in incomplete combustion, making it pollutant. It’s also difficult to light, extinguishes easily and give off significantly less heat compared to dry wood. Finally, soot can be deposited on the glass, in the appliance or the chimney. Anthracite 20/30 Use by preference coal (anthracite) with a low ash and sulphur content and with a multicaliber 20/30. Safe and natural firing It’s strongly recommended to start the fire with biomass firelighters or chopped wood, not with newspaper. Liquid fuels are prohibited! Use only environmentally friendly fuels Under no circumstances burn impregnated wood, plywood, pallet wood, chipboard, waste or newspaper in your stove. This is quite rightly prohibited by the environmental legislation. During the combustion of these fuels high concentrations of harmful substances are released. The combustion of above-mentioned fuels is also harmful for the stove and chimney. The temperature in the appliance can rise too high with the risk of a chimney fire. First use During first use the paint of the appliance will dry. Therefore burn the first hour a small amount of fuel (1-2 kg) and leave the combustion air fully open. The smoke that emits during this phase isn’t toxic but it’s recommended to ventilate the room. Also, during this process it isn’t recommended to touch the paint. Stay with the appliance during this phase and remove any condensation immediately before it has the chance to burn into the paint. Do not place kettles, casseroles, etc. on the polished cooking plate of the SAEY 92 TOP for one month after first use.

General use Opening the fire door Pull the door handle towards you to open the door and push it away from you to close it. The exterior of the stove can become very hot. We recommend using the heat resistant gloves or the operating handle. The appliance can only be used when the fire door is closed. Once in operation, the fire door may only be opened briefly to charge wood. Ash door The ash door must remain closed during operation. Otherwise air will enter the combustion chamber through the ash door in an uncontrollable manner. The ash door may only be opened for the removal of ashes. Pay attention to the heat and use the heat resistant gloves. Opening the filling lid The filling lid can simply be opened by means of the operating handle. Converting from coal to wood By default the appliance is configured for the burning of coal. It can be converted to a wood stove as follows: 1. Open the filling lid and remove the hopper 2. Place the optional wood grill on top of the coal grill (occasional wood burning) or instead of the coal grill (long term wood burning) 3. Open the air inlet between the fire door and the ash door (this air supply needs to be closed during the burning of coal) 4. Turn the 2 sliders above the fire door a quarter to the left so that the air supply can be controlled (this air supply needs to be closed during the burning of coal) Controlling combustion air Combustion air is adjusted by means of the thermostatic control at the back of the appliance. When used as a wood stove the air supply is also adjusted with the help of the sliders above the fire door.




Lighting 1. Set the air supply to its maximum capacity when lighting the fire (thermostat in position 8). 2. Open the fire door and place a fair amount of kindling on the wood grill. 3. Add 2 to 3 firelighters, spread over the kindling wood, in the front and at the back. 4. Then add a few small logs on top. 5. Now light the firelighters. 6. After the stove has been lit, the fire door must be firmly closed. NOTE Do not open the fire door or the ash tray except when adding more wood. If there is still a backdraught of flue gases 15 minutes after lighting because of the weather conditions (strong wind or fog, for example) the fire should be extinguished until the weather improves. Stoking coal The stove may be filled up as soon as the kindling has been burned and a glow bed has developed. The hopper may only be filled until the marker but needs to be at least half full. The top slots in the hopper must stay free so that gases can escape. It’s recommended to put the thermostat in a lower position after approximately 30 minutes. The final adjustment of the thermostat depends on the desired heat and must be defined in function of this. Prior to filling up the shaker grid must be shaken by means of the lever. Also, put the thermostat in position 8 before opening the filling lid. Hence gasses in the hopper and burning chamber cannot enter the room. Stoking fire wood In order for the appliance to reach the preferred temperature and as a consequence limiting the release of harmful substances, please take the following instructions into account: 1. Place 2 to 3 logs inside the stove. 2. Leave air supply fully open for a few minutes until you get the fire going again. 3. Put the thermostat in position 1-2 and adjust the air supply above the fire door until nice, stable flames develop. When the supply of oxygen to the fire is obstructed, the combustion will be incomplete and many harmful substances will be released. To reduce the side-effects of this process, it’s best to let the fire burn for half an hour at full power every day that it is used. Also avoid adding excessive fuel. As a result , too much heat is released and the temperature in the appliance can rise too high.



Generally speaking the stove should undergo a thorough maintenance at least once a year if the appliance is used frequently. We recommend carrying out smaller maintenance work such as removing ashes and cleaning the glass at more regular intervals. Note that the stove may only be cleaned when it is cooled down. Removing ashes Depending on the frequency of use, the ashtray should be emptied regularly in order to avoid the ash from reaching the wood grill. When it does reach the wood grill, the grill cannot cool down and the cast iron parts will start melting. Fill the ash tray with the help of the shaking grid lever. From to time residual ashes should be removed from the coal or wood grill using the poker. Simply hook the pin of the operating tool into the front plate of the ash pan and carefully pull it out of the appliance to empty it.

Removing the grid and hopper After regular use (depending on the amount of ashes) the burning chamber, the grid and the space of the ashtray must be cleaned thoroughly. It’s recommended to use a vacuum cleaner for this. Make sure the stove is cooled down first. Take out the hopper, remove the coal or wood grate from the frame. Finally remove the ash tray from the appliance.
Cleaning the flue Flue dust and ashes must be removed from the smoke discharge duct (between the cleaning hatch and the back plate) every year. The smoke discharge duct can be accessed by removing the cleaning hatch. This makes it easy to remove the ashes from the discharge duct as well as the connector. The cleaning hatch must remounted correctly afterwards.

Cleaning painted surfaces Dust the remaining ashes from the painted parts using a soft hand brush or cotton cloth. Never wash the appliance with water! This can cause rust.
Cleaning the cooking plate The polished cooking plate will glow wand turn blue during use. This is a normal phenomenon. The polished cooking plate can be cleaned using steel wool and the optional cleaning product. Avoid spilling water on a hot cooking plate as this may burst the plate!

Cleaning the glass

The fire doesn’t burn well Damp wood Use dry wood (moisture content ≤20%)
Inappropriate fuel Only use recommended fuels
Poor chimney draught (min 8 Pa) Check the air-tightness of the flue Close the chimney’s cleaning hatches Clean the flue
Insufficient combustion air Check diameter flue outlet and supply of combustion air Check if extractor fans are operating in the same room
Glass blackens quickly Damp wood Use dry wood (moisture content ≤20%)
Inappropriate fuel Only use recommended fuels
Filled too much wood Do not fill more than 2-3 wood logs
Insufficient combustion air Check diameter flue outlet and supply of combustion air Check if extractor fans are operating in the same room
A strange odour and smoke develops during first use
Baking in of the paint The odour and smoke will dissapear after a while
Condensation High difference in temperature Open the door for 2-3 min when lighting the fire. Do not leave the fire unattended!
Smoke hindrance Poor chimney draught (min 8 Pa) Check the air-tightness of the flue Close the chimney’s cleaning hatches Clean the flue
Fuel isn’t entirely burnt Only fill wood logs when flames are dying out
Chimney fire Innapropriate fuel Overcharge Poor maintenance
Immediately close the air supply and contact the fire department
We stock most spare parts for our products. Check on www.saeyheating.com/en/service the spare parts for your product, note down the reference number and request the spare part from your point of sale. For spare parts both under and outside of warranty, please contact your point of sale.
Fault Cause Solution