Kurzanleitung Guide de Démarrage Rapide


Button Function 1 LCD Display 5 Length/Tone Mode 2 Voice Mode 6 On/Off and ID Mode 3 Video Mode 7 Main Unit Remote 4 Data Mode (RJ11/RJ12, RJ45)
English

A. Plug the wire into the correct Test Port, e.g. Ethernet to RJ45 B. Plug the opposite end into the Main Remote C. Press Network Button D. The LCD Display reports wire condition, Pass/Fail E. To turn off, press O/ID Button
LCD illuminates B. To select a tone cadence, press the LENGTH/TONE button repeatedly to
step through the four cadence options: HI, LO, Hi-Lo1, and Hi-Lo 2. Stop when you reach the option you want. The option you select determines the cadence sent from the main tester, through the cable, and picked up by the tone tracer probe*. C. Press the appropriate cable type button (voice, video or data) to select a
cable for the tone signal * Note: Tone is detected by a tone tracer probe (optional)
Length Measurement: A. Make sure the CM450 is turned OFF. B. Insert the cable plug into the corresponding receiver on the main tester
(RJ-11/RJ12) jack for voice cable, RJ-45 jack for data cables, F-Connector for video cables). C. Press the LENGTH/TONE button to enter Length Mode. D. Press the cable type button corresponding to the connector in use
Features: Testing: CM450 shows Opens, Shorts, Miswires, Split Pairs, PASS and FAIL results quickly. Toning: CM450`s built- in tone generator is a flexible and function- packed Tone generator. Its configurable signal can be generated to find and fix the position on any type of cable – either exposed or hidden, in ceilings or behind walls. Length: CM450 determines the length (in feet or meters) of an entire cable and/ or individual wire pairs within the cable. Option: CM450 is supported by (1-19) wiremapping ID locators (Network/Coax) and (1-8) testing/ID remotes (Network/Telephone).
English

Funktionstasten 1. LCD Display 2. Sprachmodus 3. Videomodus 4. Datenmodus
Deutsch

Touches 1. Ecran LCD 2. Mode Voix 3. Mode Vidéo 4. Mode Données
France

Psiber US: Psiber Data Sytems Inc. 7075-K Mission Gorge Road San Diego, CA 92120 Phone: +1 (619) 287 99970
Psiber Data Pte. Ltd.: 3 Science Park Drive #03-09 The Franklin Singapore Science Park 1,
For technical information and support please
contact the Psiber Office in your country.