Detailed information can be found on the indicated pages.

S-VIDEO VIDEO
CVC super-Crystal View Control super: The image is automatically set as clear and sharp as possible.

Side


SV120 HV60 HV65 HV55 HV50 MV20 SV121 HV61 HV51 MV21 MV16




N2QAJB000088:NV-SV121, NV-HV61, NV-MV21 N2QAJB000090:NV-HV51, NV-MV16


Follow the steps described below.

D If the menu country
If it does not appear to be switched on, you can set the device in delivery state (page 17). The VCR Auto Setup will then start again.
Disconnect all devices from the power grid.
Connect the antenna to RF IN (antenna input) of the VCR.
! Turn on your TV. ! Then, turn to it. Standby/On switch the VCR.
The Country menu appears. ! Select the appropriate country with the arrow keys and confirm ENTER. The search run for all receivable television stations starts. Duration approx. 5 minutes.
Connect to RF OUT (antenna output) of the VCR with antenna input of the television.
When the Date/Time menu appears If the date and time are not transmitted via a television station, these must be set manually.
Connect the AV1 socket (21-pin scart jack) of the VCR to the TV's scarf input.
! Time and date with or ... enter, then with ENTER store.
D Incorrectly set date or time affect the
programmed recording of television broadcasts. (Note summer and winter time).
Connect the VCR and TV to AC power grid.
After the automatic search run, the date and time must be set manually.
! Time and date with or ... enter, then with ENTER store.

This VCR has the S-VHS format, which achieves high image quality when playing an S-vHS video cassette. When connected with S-VIDEO cables, you can also play back cassettes that were recorded using the conventional VHS system.
Follow the steps described below.

Disconnect all devices from the power grid.
Connect the antenna to RF IN (antenna input) of the VCR.
D If the menu country
If it does not appear to be switched on, you can set the device in delivery state (page 17). The VCR Auto Setup will then start again.
Connect to RF OUT (antenna output) of the VCR with antenna input of the television.
! Turn on your TV. ! Then, turn to it. Standby/On switch the VCR.
The Country menu appears. ! Select the appropriate country with the arrow keys and confirm ENTER. The search run for all receivable television stations starts. Duration approx. 5 minutes.
Connect the S-VIDEO output of the VCR to the S‐VIDEo input of the TV.
When the Date/Time menu appears If the date and time are not transmitted via a television station, these must be set manually. ! Time and date with or ... enter, then with ENTER store.
Connect the AUDIO output of the VCR (L//R) to the Audio input of the TV.
D Incorrectly set date or time affect
Connect the VCR and TV to AC power grid.
the programmed recording of television broadcasts (watch summer and winter time).
(Automatic settings) · Only for SV121 · Power cable

Follow the steps described below.
You can connect the VCR to your TV with an RF coaxial cable.

D If the menu Country after
If it does not appear, you can set the device to delivery state (page 17). The VCR Auto Setup will then start again.
Disconnect all devices from the power grid.
1 Connect the antenna to RF IN (antenna input) of the VCR.
The Country menu appears. ! Select the appropriate country with the arrow keys and confirm ENTER. The search run for all receivable television stations starts. Duration approx. 5 minutes
Connect to RF OUT (antenna output) of the VCR with antenna input of the television.
When the Date/Time menu appears If the date and time are not transmitted via a television station, these must be set manually.
! Time and date with or ... enter, then with ENTER store.
D Incorrectly set date or time affect the
Connect the VCR and TV device to AC power grid.
programmed recording of television broadcasts. (Note summer and winter time.)
After the automatic search run, the date and time must be set manually.
! Time and date with or ... enter, then with ENTER store.
(Automatic settings) · Power cable


If you want to connect the TV only via RF coaxial cable, you need to tune the video output channel with the input channel of the television. Television sets
! Press MENU,
The screen menu appears.
! Turn on your TV. ! Then, turn to it. Standby/On switch the VCR. ! Press MENU Approximately 5 seconds. The preset channel
! Select with date/time.
! Press ENTER.
VCR Ch:36
appears in the VCR display. ! Tune the TV until the test image appears.
For image interference, select a different channel on the TV and VCR.
! Press the button CH to change the channel
(e.g., Channel 39. Tune the TV until a clear test image appears
! [AUTO] and with ENTER
confirmation.
! With ENTER confirmation.
If the device does not find a transmitter that sends the time signal, set the time and date manually.
Continue the VCR Auto Setup (Automatic Settings). D The VCR does not automatically start the VCR Auto Setup if
VCR Ch:39
This has already been done once. Set the device to delivery status (page 17). After that, you can start the VCR Auto Setup again. D Press EXIT, If you cancel the VCR Auto Setup
would like to. You can do the VCR Auto Setup again.
! [MANUAL] and choose with ENTER
If you use a 21-pin scart cable, please run the following settings to turn off the RF output channel of the VCR.
confirmation.
! Time and date with or ... enter, then with ENTER store.
21 69 ...
! Press MENU Approximately 5 seconds. The preset channel
appears in the VCR display. ! Press the program selection button CH or 0 And then they call it. ! With ENTER confirmation.

Connection of set top box, satellite receiver, decoder or a second recorder. You can connect a set top box for receiving digital terrestrial signals (DVB-T), a satellite receiver (digital/analog) or a decoder to decrypt programs.

Disconnect all devices from the power grid. Connect the external device to a 21-pin scart cable on AV2 of the VCR. Connect the VCR, TV and External to AC power grid and turn on devices. ! Press MENU. ! Select with the menu Settings

Band length : AUTO( E-240) AV2 jack : EXT TV System : Auto SQPB :Auto OSD display : 4 : 3 Power save : FROM VCR display .
and confirm with ENTER.
Set Top Box, satellite receiver, second recorder:! Then, select the AV2 socket and set it to [EXT].
. set to . With this setting, it is not possible to change the option AV2 IN. ! With MENU Back to the menu screen.
AV1 OUT : VIDEO TV System : AUTO S-VHS playback : Auto OSD Display : 4 : 3
When using a decoder channel set to decoder.
Set channel to decoder! Press MENU. ! Select with the sender table menu

: : PREM : 97 : AUTO : : PAL :
1 ARD 7 2 ZDF 4 3 N3 2 4 RTL 12 5 SAT1 13
6 VOX 8 7 PRO7 95 8 RTL2 85 9 PREM 97 10 S-RTL 98
and confirm with ENTER. ! Choose to change with ENTER. ! Encrypted channel with , select and ENTER confirmation. ! Decoders with dial and [on]
with selecting. ! With MENU back to the transmitter table.

Connection of an amplifier Disconnect all devices from the power grid. Connect your VCR to the stereo amplifier with an AUDIO cable.

Left = white (L) Right = red (R) Connect the VCR, TV and amplifier to AC power grid.
D With a Scart adapter cable, you can also use the AV output of the VCR with
an amplifier.

Connection to AV3 input
! Connect the VIDEO/S-VIDEO output of the device to be connected
with the VIDEO/S-VIDEO front input of the VCR. (for example, a video camcorder)
! Connect the AUDIO output of the device to be connected with
AUDIO input of the VCR.
! A3 with INPUT SEL Selection
D To record the audio signal in mono format, only use
the L/MONO input.
AUDIO cable Amplifiers · Video audio


With the direction buttons of the remote control, you can move around in the menus and change the selected entries.
-- -- / -- --:-- --:-- - --- -- -- / -- --:-- --:-- - --- -- -- / -- --:-- --:-- - --- -- -- / -- --:-- --:-- - --- -- -- / -- --:-- --:-- - --- -- -- / -- --:-- --:-- - ---
! Press MENUThe screen menu appears.
! Choose with the desired submenu.
! Press ENTERThe selected menu appears.
Recording programming Channel table Date / Time settings Language selection : German
! Select the entry you want to change and confirm with ENTER. ! Make your changes.
Follow the menu.
! With MENU Back to the previous menu.
! Press EXIT to leave the menu.
D Not all functions are available in every model.
AV1 OUT : VIDEO TV System : AUTO S-VHS playback : Auto OSD Display : 4 : 3


! Press MENUThe screen menu appears.
1 ARD 7 2 ZDF 4 3 N3 2 4 RTL 12 5 SAT1 13: delete : move A B
6 VOX 8 7 - 8 - 9 - 10 -
! Select the sender table menu and confirm with ENTER.
! Confirmation They change with ENTER.
! Choose with a free station.
! Press ENTER.
! Channel with or ... enter. The channel tuning starts. Wait a moment until the desired transmitter is set. Image disturbances may occur. It can be minimized with fine tuning.
: 7 : - : : AUTO : AUS : AUTO : AUS
! With MENU back to the transmitter table.
Possible options for channel coordination
D Not all functions are available in every model.

Enter TV stations again


Change the name of the television station
! Press MENUThe screen menu appears.
! Select the sender table menu and confirm with ENTER.
1 ARD 7 2 ZDF 4 3 N3 2 4 RTL 12 5 SAT1 13
6 VOX 8 7 PRO7 95 8 RTL2 85 9 KABE 97 10 S-RTL 98
! Confirmation They change with ENTER.
! Select with the sender name.
! Press ENTER.
! Call with the name of the television station. The cursor jumps to the first letter.
: 1 : : 7 : AUTO : AUS : AUTO : AUS
! Change the letter with
! Next letter with the choice, .
! Press MENU.
The new name is stored in the sender table.
Change the order of television stations or delete channels
! Press MENUThe screen menu appears.
1 ARD 7 2 ZDF 4 3 N3 2 4 RTL 12 5 SAT1 13: delete : move A B
6 VOX 8 7 PRO7 95 8 RTL2 85 9 KABE 97 10 S-RTL 98
! Select the sender table menu and confirm with ENTER.
! Confirmation They change with ENTER.
! Press , the selection field is marked by an arrow at the left edge.
! You can now move to the desired place with the transmitters.
! Press ENTER.
! Press , to delete the transmitter.


! Press MENUThe screen menu appears.
! Select the sender table menu and confirm with ENTER.
! Choose with Recreate and Confirm ENTER.
! Press ENTER, around which Confirm security request.
The menu country selection appears. ! Select the country and with ENTER confirmation.
The Sender Table Auto menu appears. The station search run starts automatically.

! Press MENUThe screen menu appears.
! Select the sender table menu and confirm with ENTER.
! Choose to delete data and confirm with ENTER.
! Press ENTER, around which Confirm security request.
D To establish the delivery state, disconnect the power cable for a short time
from the power grid. Then you need to perform the VCR Auto Setup again.

Band length Adjustment of the tape length of the cassette used.
( ), AUTO E - 240 E - 195, E - 260, E - 300

To select the type of external device connected to the AV2 socket of the VCR.
Satellite receiver.
AV1 OUT : VIDEO TV System : AUTO S-VHS playback : Auto OSD Display : 4 : 3
To receive an S video signal from an external device connected to the AV2 socket of the VCR.
VIDEO : If the device It does not support S-VIDEO. S-VIDEO: If the device: S-VIDEO is supported. Connection with a 21-pin scart cable.
VIDEO: Video signal via the 21-pin scart cable. S-VIDEO: S-video signal via the 21 pin Scart cable.
Band length : AUTO( E-240) AV2 jack : DECODER TV System : Auto SQPB :Auto OSD display : 4 : 3 Power save : FROM VCR display .
AUTO: Automatically differentiates between PAL, MESECAM. PAL: When the PAL system is used. MESECAM: If this MESECAM system is used.
AUTO: The VCR automatically detects the recording type. EIN: To Playback of an S-VHS cassette in the S-vHS format. AUS : To Playback of recordings in VHS format.
Band length : AUTO( E-240) TV System : Auto SQPB : Automatic OSD Display : 4 : 3 Power save : Off VCR Display ; GEDIMMT EXT LINK
AUTO: The VCR automatically recognizes the recording type. EIN: Playback of an S-VHS cassette in quasi-S-VHD format. AUS: To Playback of recordings in VHS format.

You can use the 2. Call the screen.

Settings 2 / 2 Power save : OFF VCR Display : GEDIMMT S-VHS REC : A S-vHS ET REC
Power saves Only in standby
cannot be changed in power-saving mode. If you want to use an external device via the Scart socket AV2, the VCR must be switched on. AUS: Factory setting, the VCR display entry can be changed.
Only if the Power save setting is turned off.
VCR Display GEDIMMING: The VCR display is dimmed. EIN: The VCR display is illuminated normally.
Only if you use the TV system PAL.
EIN: For recording an S-VHS cassette in the S-vHS format. AUS: For recording an S-VHS cassette in VHS format.
Only if you use the TV system PAL.
EIN: Recording with a higher image quality when using a VHS-HG cassette. AUS: Recording with normal quality.
Only in standby · only in SP mode

Set the television to video playback channel and insert cassette with an intact anti-extinguishing tab into the VCR. ! Select the channel for recording.
REC
If recorded from an external device, select the Scart input AV1, AV2 or the Front input Av3. ! Press RECto start the recording. ! Press STOP to finish the recording.
Direct recording of the VCR television image.
! Press PAUSE/SLOW to interrupt the recording.
In order to protect the video heads, the function is performed after approx. 5 minutes off.
! Press again PAUSE/SLOW to continue the recording.
D recordings in S-VHS or S-vHS ET REC mode are only possible,
if you are using the TV system PAL (only for SV121, page 19).
Band speed! Select the tape speed with the button REC MODE In front of
Repetition of programmed recordings.
Recording.
SP : Normal recording time - optimal image quality LP : Double recording time - simple image quality EP : Three-time recording time - reduced image quality
When playing an LP or EP recording, some cassettes (e.g. Type E-300 image interference. These are not malfunctions.
Recording programming with the ShowView function.
Band-Residual Time Display The VCR display shows: time - counter - remaining band time. ! Press STATUS Until the sign appears.
Tape pick-up is controlled by an external device.
Timed recording

Recording programming allows you to enter the recording time of broadcasts up to 1 month in advance. Via the screen menu you can program a maximum of 16 recordings.

! PROG/CHECK Press and choose free space. ! With ENTER confirmation. ! Select the station and set it with date, week or day of the week. ! After that, enter start and end time . ! Hold the buttons, time changes in 30 minute steps. ! Select the belt speed: A (automatic), SP, LP, EP, .
Pos date start stop VPS PDC 1 ARD 31/12 10:30 11:30 SP A 1 ard 31/12 11:30 12:30 SP a 2 ZDF 31/12 12:30 13:30 SP An 4 RTL 31/12 13:30 14:30 SP AN 6 VOX 31/12 14:30 15:30 SP IN - - -- - - – - - : - -, - -
! The VPS/PDC setting can be changed. (not for HV51, MV16)! Programming with ENTER store. ! For further recordings repeat these programming steps. ! The video recorder with the button TIMER switched into readiness for reception.
Make sure the VCR indicator appears.
D Don’t forget to check the band remaining time. The duration of the recording may be:
do not exceed the remaining time on the video cassette.
Reception readiness cancellation! TIMER press, the VCR indicator goes out.
Now you can play a cassette or do manual recording. After that, you must TIMER press again in order to restore the programmed readiness for recording.

Testing the programmed recording
! Press PROG/CHECK,
A: If the remaining band time is sufficient at the start of a programmed
recording is not off, the function SP/LP switches over to the belt speed LP. This ensures that the entire shipment is recorded. If the remaining band time is not sufficient even in LP mode, the shipment cannot be recorded until the end. D An automatic switchover to EP mode is not possible.
The Recording Programming menu appears. ! Press again PROG/CHECK or EXIT,
to leave the menu.
Deleting or modifying a programmed recording
! Press PROG/CHECK,
The Recording Programming menu appears. ! Select the item to be changed and ENTER confirmation. ! Changes to the Entries and with ENTER confirmation. ! Press RESET/CANCEL, To the receiving
If a program start or end is shifted, this function synchronizes the recording start and stop with the effective beginning and end of the broadcast by means of a VPS signal from the transmitter.
delete.
Retrieving a programmed recording
Time must match the time specified in program journals. If a special VPS time is shown, it must be used.
! Press PROG PLAY.
The device rewinds back to the beginning of the programmed recording and starts playback.
Set the start and stop times so that when program shifts, the entire film is recorded.
Automatic SP/LP switchover · VPS/PDC function

The Intelligent Timer feature simplifies recording programming of broadcasts that are aired on the same slot, at the same time, on different days.
In order to use the Intelligent Timer function, at least one programmed recording must be created in the Recording Programming menu (page 21). This data is also included in the Intelligent Timer menu. In the Recording Programming menu, data is deleted from the device after recording has been completed but remains available in the Intelligent Timer Menu. From here, you can transfer this data back to the Recording Programming menu and reprogram it for a recording with changed values.
The data of the last 5 programmed recordings are transferred to the Intelligent Timer menu.

Take over stored recording programming! Press I-TIMERS . ! recording with or without I-TIMERS Selection. ! Press TIMER, to switch into the reception readiness.
VPS PDC 1 ARD 25/10 10:30 11:30 SP EIN 1 ARD 25/10 18:30 19:30 SP AUS 2 ZDF 25/10 12:30 13:30 A EIN
Change the program data ! Press I-TIMERS. ! recording with or without I-TIMERS Select and with ENTER confirmation. ! The recording programming screen appears. ! Change the desired data and with ENTER save the change. ! Press TIMER, to switch into the reception readiness.
: change : resp. : locked : delete : cancel
Protecting I-TIMER programming If 5 entries are stored in the Intelligent Timer menu, each additional entry will delete the oldest programming. ! Press I-TIMERS. ! Select the entry with . ! To protect the entry, press . The symbol appears. ! To remove the protection, press . The symbol is extinguished.
1 ARD 26/10 10:30 11:30 SP EIN 1 ARD 26/10 18:30 19:30 SP AUS -/ - :-:-/ - :-:-/ - :-:-/ - :-:-/ - :-:-

SV120 HV60 HV65 HV55 HV50 MV20 SV121 HV61 MV21 HV51 MV16

Recording Programming with the ShowView Function The ShowView Code simplifies the input of program data for recording TV and SAT stations.
8 3 5 4 2 -
! Press ShowView. ! Enter ShowView number. (Correct the input) ! With ENTER take over the input.
: Enter : dial 0 - 9 : correct : cancel
The recording programming screen appears.
If the transmitter is not automatically recognized, it must be entered with. This information is stored by the VCR and does not have to be entered in future.
1 ARD 31/12 10:30 11:30 SP EIN 1 ARD 31/12 11:30 12:30 SP EIN 2 ZDF 31/12 12:30 13:30 SP AUS -/ -:-:-/ -:-:-/ -:-:-
Activate recording programming ! Press TIMER, to switch into the reception readiness.
The icon appears in the VCR display.
Changing the programming data! Press PROG/CHECK,

ShowView is a registered trademark of Gemstar Development Corporation. The ShowView system was manufactured under license from Gemstar Development Corporation.
The Recording Programming menu appears. ! Select the item to be changed and ENTER confirmation. ! Select the station and set it with date, week or day of the week. ! After that, enter start and end time . ! Select the belt speed: A (automatic), SP, LP, EP , and with ENTER confirmation. ! Press TIMER, to switch into the reception readiness.
ShowView


! Press MENU, the screen menu
appears.
! Select with the menu Settings

and confirm with ENTER
Settings 2/2 Power save : OFF VCR Display : GEDIMMT S-VHS REC : A S-vHS ET REC
! Then, select the tail and set it to [2] or [1]. ! With MENU Back to the menu screen.
EXT LINK 2: External recording control of some satellite or digital receivers (video signal).
EXT LINK 1: For digital receivers which transmit a special recording control signal, e.g. The F.U.N. receiver (TU-DSF41).
! Press EXT LINK, to switch the VCR into readiness for recording.
Make sure that the VCR indicator EL1 or EL2 appears. As long as the satellite or digital receiver transmits (EL 1) the special recording control signal, or as long as a video image is transmitted (EL 2), the VCR records.
EXT LINK 2 has been started.
! Press ENTER, to hide the hint. ! Press EXT LINK, to stop the recording.
D The programmed recordings of your VCR must not be compatible with those of the
Satellite or digital receivers overlap.
Reception readiness cancellation! Press EXT LINK, to interrupt the readiness for reception.
The indication EL 1 or EL 2 is extinguished. Now you can play a cassette or do manual recording. Press again EXT LINKto restore receptiveness.

Normal reproduction! Turn on the VCR. ! Make sure the TV is turned on and on
Usually, the VCR automatically sets the playback image to best picture quality. Sometimes it may be necessary to regulate them manually.
the video playback channel is set. ! insert video cassette. ! Press PLAY to start the playback. ! Press STOP to terminate the playback.
The image is noisy or fuzzy during playback. (track tracking scheme)
! Press them during the
normal playback or in slow motion, the program dial (-) or (+), until the noise disappears. If noise appears in the still image, switch the VCR to slow motion first and subsequently regulate the track position.
Reproduction from electrical ready for use When you put in a cassette and PLAY Press, the device is switched on and playback begins.
Start of automatic playback If you insert a cassette with the anti-extinguishing tab broken out, playback starts automatically.
Endless reproduction The VCR repeats the recording on the cassette until the end of the recording. ! Press PLAY more than 5 seconds during the
D In some video cassettes, the track position cannot be
Rules. The VCR shall not be malfunctions.
Playback or stopping. The VCR display shall show [R]. ! Press STOP to terminate the playback.
Automatic track position control! Press (-) and (+) simultaneously.
The still image shifts up or down! In still image mode, hold (-) or (+) until the picture is stationary.
Time-limited recording and reproduction Switches the device to standby after a selected time during recording, playback or stopping. Each additional button press increases the time from 30 to 60, 120, 180 or 240 minutes. The set time appears in the display of the VCR. ! Press OFF-TIME
D Some televisions may have the following:
the image shifts up or down for special playback functions. The VCR shall not be malfunctioning.
Optimization of the reproduction image

SV121 HV61 HV51 MV21 MV16 SV121 HV61 HV51 MV21 MV16
Auto-start When you insert a cassette, the VCR is automatically turned on.
Quick search for a start of recording During playback or in stopping mode. ! INDEX Band winding before / INDEX The band rewinds. According to each key press (maximum 20 times), the VCR winds at the corresponding start of recording. The playback begins automatically. ! Press STOP to terminate the search run.
Automatic rewinding Once the cassette end has been reached, the VCR automatically rewinds back to the tape start. D This function is not during a programmed
recording possible.
Image search forward or backward ! Press during playback or .
Still image reproduction! Press PAUSE/SLOW during the playback. ! To finish still image playback, press
The image search starts. ! When you press the button twice (JET SEARCH) it increases
Renewed PAUSE/SLOW or PLAY.
the search speed. ! Hold the button, starts the image search for
Slow-motion reproduction (not for MV21, MV16) ! Press PAUSE/SLOW During playback longer
Duration of keystroke. ! Press PLAY to terminate the image search run.
as 2 seconds. ! To end the slow motion playback, press PLAY.
D Under certain conditions (e.g. at the beginning of the band, or
-end) this function is not available
Fast forward winding or rewinding ! Press in stop mode or . ! Press STOP to terminate the winding function.
Automatic stop function To protect the video heads, the functions of image search forward/backward, fast image search run, still picture reproduction and slow motion reproduction are automatically terminated after 5-10 minutes. Image disturbances and drive noise are not functional interference.
JET REW For rapid rewinding back to the cassette start. In the case of an E180 cassette approx. 43 seconds. D The tape counter and the band residue display are shown in this
Function not available.

Operation only on the device.
Operation only on the device.
Band counting equipment The tape counter is automatically set to [0:00.00] when a video cassette is inserted. ! The tape counter can also be pressed by pressing the
Automatic switching off and cassette removal If the VCR is switched to standby, the cassette can be opened by pressing EJECTED-Key can be removed. The VCR then switches back to standby.
RESET/CANCEL-Button to [0:00.00] be set.
QUICK ERASE To be able to record on a recorded cassette again with trouble-free quality, delete the recordings contained in the casing with QUICK ERASE-function. ! Press and hold for a few seconds
AUDIO setting Sound playback mode by repeatedly pressing the key AUDIO AUDIO Selection. Playback Stereo: Display: L R left channel: Display : L - right channel: Show : - R Playback Mono: Display
QUICK ERASE-Button. The erasing process takes approx. 30 minutes.
3D DNR, 3-dimensional digital noise suppression Improvement of image quality by noise reduction. ! Press them. 3D DNR-key, to switch off the function.
To protect against unintentional erasing of cassettes, the anti-extinguishing flap is broken.
The status is displayed on the television.
If you want to re-receive a protected cassette, close the gap with adhesive tape.
TBC, TIME BASE CORRECTION offers an undistorted and stable reproduction of the image quality. ! Press them. TBC-key, to switch off the function.
The status is displayed on the television.
Cassette extinguishing protection

Select the Mono setting: [ON] if you want to record the monotone on the hi-fi tracks of the VCR, or the stereo is disturbed due to poor reception conditions.

! Press MENUThe screen menu appears.

: 1 : ARD : 7 : AUTO : AUS : PAL :
! Select the sender table menu and
confirm with ENTER.
1 ARD 7 2 ZDF 4 3 N3 2 4 RTL 12 5 SAT1 13
6 VOX 8 7 PRO7 95 8 RTL2 85 9 KABE 97 10 S-RTL 98
! Confirmation They change with ENTER.
! Select with the desired channel and confirm ENTER.
! Then, choose the one and select it or not.
pose.
! With MENU back to the transmitter table.
Playback of NTSC video cassettes You can play NTSC video cassette to watch on a PAL TV. If NTSC playback is disrupted, try to recreate your TV. Read the TV's instruction manual. Recording and transferring video cassettes to the NTSC format is not possible.

The video recorder display does not light up:
Imaging or sound disturbances:
! When using E-300 cassettes, which are connected with the slow
! Check the power cord connection.
tape speed (LP or EP) are recorded, interferences can occur.
! Check the Power save setting
! Then check the [PAL] setting, [MESECAM].
The video recorder display is lit, the device cannot be operated:
! Check the connection and function of antenna or scart cable.
! The device is in readiness.
! Check the SQPB/S-VHS playback setting for
Finish them with the TIMER-The key or the EXT LINK-Button.
S-VHS cassette.
! error in recording at reduced tape speed (EP)
Increased drive noise:
[MESECAM] are not malfunctions.
! If the video heads are dirty or worn, contact
! During the fast forward or rewinding, drive noises are generated.
These are not malfunctions.
Your customer service.
! Cleaning the video heads by a customer service workshop will not
The remote control functions are disturbed:
covered by the guarantee.
! Check the distance to the device (max). 7 meters.
The recording functions are disturbed:
! Check the batteries of the remote control
! Blinks on the device, check the erasure protection of the video cassette.
Automatic time setting does not work correctly:
! Check the date/time.
! . Check start and stop time of recording programming
! Set date/time to [AUTO]
! Check if the device is programmed to record with
If the device does not find a transmitter that sends the time signal, set date and time manually.
the TIMER-key was switched into the receiving readiness
! Check start and stop time for VPS/PDC recording
If you cannot resolve any problem, contact customer service (see warranty information).

220-240 volts AC voltage, 50/60 Hz
18W 15W 15w 13W 13W This device is not disconnected from the power grid when it switches to standby mode.
In operation in Power save mode
Multifunction remote control (video and Panasonic TV) basic functions on the device
Video TV system NTSC Playback on PAL TV S-VHS Quasi Playback (SQPB) S-vHS S-vehicle ET
X X X - -
X -
X -
X -
Recording/playback time (E-240 cassette) SP: 240 min, LP: 480 min tape speed SP: 23.39 mm/s , Lp: 11.7 mm/S Video and sound heads (inclined track method) S-VHS/Hi-Fi: 4 heads / 2 sound head, Mono: 2 heads
RF converter UHF channel (21-69), 75 ohm video input and output level 1.0 Vss, 75 ohM with final PAL color signal
Audio output level -6 dBV, less than 1 kOhm audio input level - 6 dBv, more than 10 kOhM
Signal Noise Distance Audio more than 43 dB (SP, Mono) Signal Noize Video (Color) More than 43dB (Sp) Horizontal resolution (Colour) more than 240 lines (VHS, SP), 400 lines (S-VHS/S- VHS-ET, SP).
Dynamic range Audio more than 90 dB (Hi-Fi soundtrack)
Audio frequency response 80 Hz to 8 kHz (SP, mono),
20 Hz to 20 kHz (Hi-Fi audio track)
Operating temperature/moisture 5°C to 40°C/35% to 80%rel. Moisture
D Changes to technical
Weight and dimensions (approximate values) 3.5 kg/430(B) x 89(H) x 276(T) mm
Data reserved at any time.
Power supply · Power consumption · Playback functions

Page page 3D DNR 4,28 Ssatellite receivers 12, 19, 25 Fone-tuning 15 scart cable 8 remote control 6,7 fast coils 6,27 AC IN 5,8,9.10 Set Top Box 12 AUDIO Output 5.9 HF-coaxial cable 10 voltage 3 AUDIO setting 28 power supply 31 INDEX 27 Automatic SP/LP switchover 22 SQPB 18.30 Intelligent TIMER 7.23 Automatic stop function 27 Still image playback 27 Automatically off 28 Start of automatic reproduction 26 JET REW 27 Automatic rewinding 27 Search for a start of recording 6,27 JET SEARCH 27 Auto-Start 27 S-VHS ET REC 19,20 AV1/AV2 (21 pin Scart socket) 5.8 S-vHS playback 18 Kanal 11.15 AV1 OUT 18 S-VHS REC 19 cassette removal 28 AV2 socket 18 S VIDEO 18 AV 2 IN 18 S video output 5.9 Lpower receptacle 31 Anti-extinguishing protection of cassettes 28 Band speed 20 TBC, TIME BASE CORRECTION 4.28 BAND LENGTH 18 TRACKING/V LOCK 7.26 MESECAM 15,18.30 Band Remaining Time Display 7,20 TV System 18 Mono 15 Tape Counter 7,28 Motion-toward/reverse 6,27 VCR indicator 19 Name 15 VIDEO 18 Widescreen 18 VIDEo Output 5 NICAM 29 Video Sys. 15 Country 8.9.10 NTSC 29.31 CVC super 4 VPS/PDC 22
OSD display 18 WSpecies 3 Datum 11 Playback 6,26 Decoders 12,15 P Reproduction from the electric AL 15,18,30 DECODER 12,18 Operational Readiness 26 Power save 19,30 digital receiver 19,25
Zeit 11 QUICK ERASE 4,28 E26 Time-limited recording/playback 26 EXT 12 RF IN/OUT 5,8,9.10 Slow-motion reproduction 27 EXT LINK 19,25
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.