The remote actuator activates the load after a radiofrequency signal sent by the programmable thermostat ORUS RF.
ORUS RF Load Remote actuator 1 or more channels


For details about the configuration of the devices, see the section CONFIGURATION AND REMOTE ACTUATOR TEST

control via radio frequency signal. It is suitable for environments with a pollution degree of 2.
Code Model Description OB324900 Orus RF Digital programmable thermostat RF control white
with the following instructions:
- T3, T2, T1 for automatic regulation
- T0 antifreeze temperature setting in advanced programming
- T temperature in manual operation

The preset temperature values (expressed in °C) are the following:
funct. winter funct. summer
T2 15.0 23.0
T3 18.0 25.0
T MANUAL 20.0 24.0
Regulation of temperature levels is subjected to the following condition: T1 ≤ T2 ≤T3. In summer mode, T1 cannot be set and corresponds to the air conditioning OFF.


1) “ ” Key: manual operation 2) “ ” Key: increases the selected field or displays the daily maximum temperature 3) “ ” Key: decreases the selected field or displays the daily minimum temperature 4) “ ” Key: confirms the set data 5) “ ” Key: activation and deactivation of the programmable thermostat 6) “ ” Key: selects temperature T3 7) “ ” Key: selects temperature T2 8) “ ” Key: selects temperature T1 9) “ ” Key: allows to set a timer or an activation delay 10) “ ” Key: programs setting or advanced programming 11) “ ” Key: clock setting 12) “ ” Key: winter operation (preset) or summer operation (the button is reachable only with a point) 13) “ ” Key: deletes date and time but not the set programs (to do this see "Restoring default parameters" page 56) (the key is reachable only with a point).




so only once the clock is set.


At this point, the minutes digit will start flashing. Use the “ ” and “ ” keys to increase or decrease the field and press “ ” to confirm. Repeat the procedure to set the hours.


Once the value for the hours is set, field (22) will display a flashing value of the year, field (15) the value of the month and field (16) the value of the day.

Press the “ ” and “ ” keys to modify the values and “ ” to confirm. Once the day is set, press the “ " key to exit the menu. Upon exiting such procedure the clock indication will not flash any more; field (16) will display the environment temperature again.





With the T1, T2 and T3 keys, it is possible to modify the temperature selected for that hour and, at the same time, move on to the next one. Using the “ ” and “ ” keys, it is possible to move from one hour to the next without modifying the set temperature.

Pressing the “ ” key, it is possible to set the activation delay for that specific hour. Each pressure of the “ ” key increases the delay by 15 minutes.
Pressing the “ ” key confirms the modified program and returns to the situation with “Px” flashing on field (16).
Pressing the “ ” key confirms the program for that day and moves on to the next until Sunday appears, after which operation goes back to normal mode.


With the “ ” and “ ” keys, it is possible to modify the value and with the “ ” key it is possible to confirm the change and return to normal operation.
The setting limits are reported in the technical characteristics.

Field (22) will show the current time. Field (14) will show the current date. Field (15) will display the writing “SEt”. The symbol (18) will appear.

Field (17) will disappear. On field (16) the set manual temperature value will flash. With the “ ” and “ ” keys, it is possible to change the value from 2.0°C to 35°C.
Pressing the “ ” key or after 45 seconds from the last operation, field (16) will display the value of the environment temperature).
At any time, it is possible to verify the set temperature pressing the “ ” key or the “ ” key; pressing one of the 2 keys again will allow modification of the temperature setting. To move from the manual program to the automatic one, simply press the “ ” key again for at least 3 seconds.


To move from winter to summer operation (or vice versa), press the “ ” key with a point (12).

On field (22) the writing “rISC” (or “Cond”) will flash and the symbol " ” (or “ ”) will appear.
With the “ ” and “ ” keys, it is possible to select one of the two operations.
The program will go to the desired operation pressing the “ ” key or after 45 seconds from the last operation. The potential of the summer operation is the same as the one of the winter operation; therefore the setting of all parameters can be carried out following the procedures reported in this instructions manual.



During summer operation, instead, the deactivated system condition completely excludes the refrigeration command. To go back to the operating mode prior to the deactivation, press the “ ” key again.
The programmable thermostat allows to activate three different timed operation modes, useful when you want to maintain a certain condition for some hours/days. The three timed operations are:
If in manual status you set a timing, such manual status will be maintained until the end of the timing; operation will then switch to automatic. If, during the timing, operation is switched to automatic or off, the timing ends.
If in automatic status you set a timing, such automatic status will be maintained until the end of the timing; operation will then switch to automatic. If, during the timing, operation is switched to manual or off, the timing ends.
Manual operation · Automatic operation

If in off status you set a timing, such off status will be maintained until the end of the timing; operation will then switch to the one active before deactivation. If, during timing, the system is activated, the timing ends.
In all cases, the timing condition is signalled by the symbol “ ”.

To activate timing it is necessary to press the “ ” key
The writing “00h” will flash, indicating the timing. With the “ ” and “ ” keys it is possible to choose a value between 0 and 99. Pressing the “ ” key will allow to choose the measurement unit between hours and days.
Each change in measurement unit implies a resetting of the set timing value. Once the value has been set, press “ ” to confirm or wait 45 seconds.
included. In the same way, if the measurement unit is in days, the count also includes the current one. Timing in hours terminate on the hour, the ones in days at midnight.
Timed deactivation · Setting a timing

- regulation type - parameters for regulation type - antifreeze temperature - temperature measurement unit - Setting/Test of the remote activator - keypad lock password - system operation hours - battery charge status

the setting and move on to the next parameter. Once the last parameter has been confirmed, you will exit the menu and the programmable thermostat will restore operation with the previously set operation.
Regulation type (only for winter operation)

Parameters for the chosen regulation type (only for winter operation)

Field (22) will display the writing “bnd=” and on field (16) the value currently set will flash. Press the “ ” and “ ” keys to increase or decrease the value. The range varies from 0.5°C to 5°C.

Once the band value is confirmed, field (22) will display the writing “PEr=” and on field (16) the value currently set will flash. Press the “ ” and “ ” keys to increase or decrease the value. It is possible to choose between 10, 20 or 30 minutes.
For a wider description on how to operate the regulation type choice, please refer to the chapter “REGULATION TYPE” on page 56.

Antifreeze temperature (only for winter operation)
Field (22) will display the writing “OFF=” and on field (16) the antifreeze temperature value currently set will flash.

Press the “ ” and “ ” keys to increase or decrease the temperature value. It is possible to choose a value between 01.0°C and 10.0°C.
It is also possible to disable the antifreeze function holding the “ ” key until field (16) displays the symbol “---”. In this case, when the programmable thermostat is off, no regulation is executed.

It is possible to choose to display the temperature in degrees Celsius (°C) or Fahrenheit (°F).
Field (22) displays the writing “dEG=” and on field (25) the measurement unit currently set will flash.

Press the “ ” or “ ” keys indifferently to change the unit and “ " to confirm.
Temperature measurement unit

The remote actuator activates the load after a radio frequency signal sent by the programmable thermostat ORUS RF.


Operation · Channel setting · ORUS RF setting

ON/OFF commands are alternatively sent every 10 seconds for 10 minutes. • To exit the modality test press the key “ ”.
It is possible to choose a three digit value to be used to unlock the keypad.
Field (22) will display the writing “PAS=” and on field (16) the password value currently set will flash (the default set value is “123”). Using the “ ” and “ ” keys, choose a desired value and press “ ” to confirm.

To enable/disable the keypad lock, please refer to the chapter “ADVANCED FUNCTIONS".
It is possible to display the system operation hours (relay in ON status).
Field (15) displays the writing “tot=” while fields (22) and (16) will display the timing value (such value is of 5 digits, 3 on field (22) and 2 on field (16) and it is to be read from left to right. In the example the value is of 1274 hours).

Keypad lock password · System operation hours

Two independent totalizers for winter and summer operation are present. The maximum memorizable value is of 65535 hours. To reset the counter, press the “ ” key for about 3 seconds when you are in the counter view menu.

It is possible to view the battery charge status.
Field (22) will display the writing “bAt=” and field (16) will show the percentage value of the charge level.

Since this is the last parameter of the sequence, pressing the “ ” key will exit the menu and return to automatic operation. If no key is pressed during setting of these parameters, automatic operation will be restored after 45 seconds.
Battery charge status

Automatic change CET / DST The programmable thermostat allows to automatically move from the CET (Central European Time) to DST (Daylight Saving Time) and vice versa. Holding the “ ” key for at least 3 seconds, the display will show the writing “Change” and field (15) will flash the writing “On" or “OFF”. Choose using the “ ” or “ ” keys and confirm with “ ”. If the choice is OFF, you will exit the menu and the programmable thermostat will not execute the hour change. If the choice is ON, then two other menus will be displayed, which define respectively the hour change from
- winter summer - summer winter (on field (20) the “ ” symbol will appear)
To modify the set values, press the “PRG” key. The parameter corresponding to the modification will start flashing. Press the “ ” and “ ” keys to modify the values and “ ” to confirm.
The settings for both menus are, in order:
- week of the month
(1ST first, 2ND second, 3RD third, 4TH fourth, LST last) - day of the week - month - changing hour
At the end of each menu, press the “ ” key again to access the next menu or to exit and return to the normal view. The default values set for the automatic time change are:
- winter summer change: last Sunday of March at 02:00 - summer winter change: last Sunday of October at 03:00


In case you want to install the programmable thermostat in public environments, it is possible to lock the keypad simply by simultaneously holding the T1, T2 and T3 keys for 3 seconds. The display will show the writing “BLOC”.
To unlock the keypad, press the T1, T2 and T3 keys again for 3 seconds and input, using the “ ” and “ ” keys, the protection password.
Display of max/min daily temperature
The programmable thermostat memorizes the minimum and maximum temperature values measured during the day. To view such values press the “ ” key (maximum value) or “ ” (minimum value). Field (16) will display the value measured. To reset the minimum/maximum value memorized, press the “ ” / “ ” key for at least 3 seconds.

Keypad lock

During winter operation, in case of sensor failure, in order to avoid problems regarding freezing, the programmable thermostat activates the relay for 10 minutes every 4 hours and field (16) will display the “---” symbol.
Simply pressing the “R” key will not cause a total reset of the instrument. To do so and allow the loading of the default values, it is necessary to press the “R” key and then, within 3 seconds, the “ ” key. The display will show the writing “dEF”.
The default regulation type is ON/OFF with deactivation in correspondence with the setpoint and with differential set to 0.3°C. During on/off operation mode, the relay of remote actuator follows the following logic:
heating mode cooling mode
SET+DIFF SET relay OFF
During heating mode the proportional regulation can be chosen; in certain types of systems, this allows to improve the regulation, in order to obtain a constant temperature. This regulation activates the ON or OFF relay within a predefined regulation cycle on the basis of the gap of the temperature measured by the setpoint value. The necessary parameters for the definition of this mode are:
The regulation band represents the temperature interval, centered on the setpoint, in which the proportional regulation is checked.

Half the desired regulation band is set in the device. The range for this parameter is 0.5 ÷ 5.0°C with 0.1°C resolution
The regulation period represents the duration of the regulation cycle (activation period + deactivation period) The value of this parameter is selectable between 10', 20' and 30'
Choose the regulation period value as follows:
Choose the regulation band value as follows:



keeps a voltage such to allow operation to the microcontroller. The replacement of batteries must take place within maximum time of one minute in conditions of flashing display. Beyond this time, date and time will be lost and must be reset upon next activation. However, the executed programs will remain memorized. The use of strictly alkaline batteries is recommended.
Compliance with Community Directives 1999/5/CE (R&TTE) 2004/108/EC (Electromagnetic compatibility) is declared with reference to the following harmonized standards: ETSI EN 300 220-1 ETSI EN 300 220-2 ETSI EN 301 489-1 ETSI EN 301 489-3


0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.