INSERTING AND CHANGING BATTERIES: The apparatus is fed by two LR6 (AA) 1.5 V alkaline batteries (not included). The polarity indicated on the battery compartment must be respected. The batteries last approximately one year. When batteries are inserted for the first time, the screen is switched on and all the display segments are shown and, after a few seconds, the timer-thermostat is ready for operation. When the MIRUS batteries have little power left and require changing, The “Lo” symbol is displayed at the bottom of the screen. In order not to lose the current time, day of the week and temperatures configuration, the battery change operation should be accomplished within fifteen seconds. In any case, the fixed programming remains stored. All used batteries shall be disposed of in a correct fashion. Respect the environment. SCREEN BACKLIGHTING When any button is pressed on the MIRUS, the temporary backlighting comes on to illuminate the display in order to easily programme the device. SETTING THE TIME The programming wheel is set to START and the button is pressed and the day of the week digit begins to flash. The or button is used to select the corresponding day, the button is pressed again to repeat the operation for the hours and minutes in this order. Five seconds later automatic mode is entered with the current time now set. AUTOMATIC OPERATION (TIMER-THERMOSTAT) When the programming wheel is set to the START position, the MIRUS will switch the heating ON or OFF according to the current day programming. The TIMER will show this programming in the display. CONTROL TEMPERATURES The factory-set temperatures are:

Comfort: 20 ºC These temperature values can be modified in START mode by pressing the button
corresponding to the temperature to be configured (Comfort or Savings ) using the or button to change the value. In order to determine the programmed type and temperature in the MIRUS at the current time when in START mode, press either the or button. PRESET PROGRAMMES The MIRUS Timer-Thermostat is factory-set with the following programming
Savings : 00:00 to 06:00, 09:00 to 12:00, 15:00 to 17:00 and 22:00 to 00:00.
Savings : 00:00 to 08:00 and 22:00 to 00:00.
Comfort: 08:00 to 22:00. MODIFYING PROGRAMMES The programming wheel is set to the day to be programmed (for example, Monday – 1, Tuesday – 2 etc.). The temperature type is programmed in 30-minute periods beginning at 00:00. The temperature type is defined by pressing the button corresponding to the desired
temperature (Comfort: , Savings: , Off: ) . When the temperature is defined, the following time period is selected. The or button is used to move through the time periods leaving the already assigned temperature. In order to determine the programmed temperature, the display will show the start time and the defined control temperature symbol will flash in the programme being modified. If there is no flashing symbol, it means that the time period being programmed the timer-thermostat is Off, however, the anti-icing mode remains activated. The programmed can be stored by moving the wheel to another day or to the START position. If, during programming, one minute passes without any button being pressed, the screen will display “Err” and the relay will de-energise until a button is pressed in order to continue with the programming operation.

If the equipment is switched On, pressing the button will switch it Off, the heating will not be switched On, the temperatures cannot be modified and the screen will be OFF. This mode, the unit measures the ambient temperature, but will not perform any of its functions, except if the temperature falls below +5ºC, at which point it will activate the de-icing programme and will switch the heating On to prevent freezing.

This mode is exited by pressing the button again. RESET The RESET is pressed in order to reset the timer-thermostat. Then all the parameters have to be reprogrammed. In any case, the last weekly programme entered prior to the reset will remain in memory. TECHNICAL SPECIFICATIONS Power supply: Two LR6/AA, 1. Alkaline batteries (not included) Switching power: µ 10 (3) A 250 Vac Contact: AgNi switched, 90/10 Battery duration: Approximately one year Temperature measurement precision: ± 0.5°C Temperature update: Every 60 seconds. Resolution: 0.1°C. LCD measurement range:: 0ºC to 50ºC Action type: 1B, 1S, 1T and 1U Number of programmes: 7 (one for each day of the week) Minimum programmable times: 30-minute periods Operational precision: ≤ ±1.2 sec/24 h at 23ºC Output relay update: Every 60 seconds Control temperature regulation: Savings : +5ºC to +25ºC
Day of the week
With the apparatus in normal mode, press the button and the timer-thermostat will operate as a normal thermostat, without any time programming, only taking into account the temperature. The desired temperature is selected simply by pressing the or button until it is displayed. The unit will commence operating as a thermostat ten seconds after the final temperature modification and display the ambient temperature and the word MANUAL on the screen.
To return to the timer-thermostat mode, press the button again. TEMPORARY MANUAL MODE This mode is used to manually modify the temperatures corresponding to the consecutive time periods with the same control temperature. When the programme changes the control temperature type, it will return to the established programme. To select this when in START mode, press the or button and the current time period control temperature will be displayed. If the or button is pressed again, the control temperature for the consecutive time periods will be modified, with the unit entering TEMPORARY MANUAL. The control temperature symbols will disappear from the display while the TEMPORARY MANUAL mode is activated and the word MANUAL will appear flashing. To exit this mode before completion, turn the programming wheel from START to
Comfort : +15ºC to +35ºC Anti-freezing: 5ºC Manual: +5ºC to +35ºC Regulation type: ON-OFF with 0.3ºC hysteresis Operating temperature: 0ºC to +50ºC Transport and storage temperature: -10ºC to +60ºC Protection class: II according to EN 60335 with correct installation Protection type: IP40 according to EN 60529 with correct installation Contamination situation: Normal Transient pulse voltage: 2.5 kV Ball test temperature: 75ºC (21.2.5); 105ºC (21.2.6) Connection Screw terminals for wires having a maximum 2.5 mm² section WARNING: Contactors must be employed if the maximum load current
any other mode and it will return to START, or the button can be pressed twice. Example: The programmed control temperature is to be temporarily modified to 22ºC, with the MIRUS programmed with the following parameters:
- Savings : 00:00 to 09:00, 13:30 to 20:00 and 22:30 to 00:00h.
- Comfort: De 09:00h a 13:30h y de 20:00h a 22:30. This is achieved in START mode by pressing the or button so that the control temperature is displayed for the current time period. the or button is pressed again to change the temperature value to 22 ºC. From this moment, the MIRUS will regulate heating On/Off until 22ºC is reached, during the time that the control temperature is consecutively programmed (the one just modified) until 20:00 when the control temperature mode is changed in the
programming to Comfort ( ). Before applying the TEMPORARY MANUAL mode, the display will show the configured chronogram: When the TEMPORARY MANUAL mode is activated the display will show the following:

Control temperature symbol for the current time (flashing)
Temporary manual operation indicator (flashing)
No control temperature symbol
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61 E–28020 MADRID Telephone:+ 34 91 5672277; Fax:+34 91 5714006