Operation and installation instructions

for NO x reduced all-gas space heaters

an automatic gas heating basic unit

Type 60 – 81 / Model Vertico Type60 – 82 / Model Lithorond

With a chimney connection

ORANIER Heiz- und Kochtechnik GmbH · D-35075 Gladenbach · Telephone (0 64 62) 9 23-0 · Fax (0 6462) 9 22 3 49

Page 2 of the Oranier Artemis user manual — Representations of the countries:
Page 2 · click to enlarge
Page 2

ORANIER - Customer service services can only be used within Germany via our central customer service.

Switzerland: Gas Center Chur M. Honegger AG Sägenstr. 75 7000 Chur telephone 81-2 53 70 71 Faxes 81-2 53 73 31 Email [email protected]

Weidenhäuser Str. 1-7 35075 Gladenbach

Luxembourg: ENERGUS S.A. 40, rue Rangwee 2412 Luxembourg telephone 40 83 80 Faxes 40 83 81 Email [email protected]

Service for standing range telephone service 0 340 / 5 19-56-12 Telephone spare parts 0 330 / 519-56-14 Fax fax 0 3 40 / 5 19.

Email wrobel@Oranier.com ziemer@Oranier.com

Central kitchen technology telephone 0 64 62 / 9 23-355 Fax 0 6462 / 9 22 - 359 E-mail: customer service-kuechentechnik@Oranier.com

Please note In order for our customer service to carefully prepare repairs and provide the required spare parts, we need the following information:

Central heating technology Telephone 0 64 62 / 9 23-360 Fax 0 6462 / 9 22 369 Email: customer service-heating technology@Oranier.com

1. Your exact address
2. Your telephone and if necessary. Fax number/email
3. When can customer service visit you?

All services are available Monday to Thursday from 7.30 a.m. to 17.00 Fridays from 7.:30 a. m. to 15.00

4. All information on the equipment plate (double in the user manual)

Outside of service hours, please let us know your wishes by e-mail or fax.

5. Date of purchase (proof of sale)
6. The exact description of the problem or your service wish.

Representations of the countries:

Austria: TGK - Austria Technical equipment customer service Obachgasse 8 1220 Vienna telephone 01-259 80 18 Faxes 01-259 80 33 Email tgk@tgk.co.at or Neubauzeile 57 4030 Linz telephone 07 32-37 18 68 Faxes 07 32-37 18 35

Customer service / spare parts

Page 3 of the Oranier Artemis user manual — Certificate of conformity
Page 3 · click to enlarge
Page 3

Your contribution to environmental protection Directive 2002/96/EC (WEEE): Information for the end user The following information is only used by final consumers who have a product on which and. a. The symbol (FIG.) A) is indicated. This symbol is located on the glue plate with the technical device data (typeplate) attached to the device: this symbol means that the product has been classified as electrical or electronic equipment due to the prevailing regulations and complies with EU Directive 2002/96/EC (WEEE). Therefore, the appliance must not be disposed of in any case after its end with normal household waste. The device is free of charge either to a permanent collection point for electrical or electronic equipment, or to a reseller when buying a new product.

Certificate of conformity

We as a manufacturer declare that the device described, with the CE-No. specified in the section “Technical data”, has been built according to the essential requirements of EC Gas Appliances Directive 90/396/EEC including modifications. The apparatus conforms to the type described in the related EC-type examination certificate.

FIG. A The end user is responsible for the transfer of the waste equipment to a suitable collection point. Otherwise, he will be punishable under the laws in force on waste disposal. Proper separate collection of waste for recycling and environmentally sound disposal avoids damage to the environment and health, allowing reuse of equipment components. For more information about the existing collections, please contact your municipality or the purchasing office where you purchased the device. Manufacturers and importers will live up to their responsibility for product recycling and environmentally sound disposal both directly and through participation in a collective scheme.

Disposal of packaging The package protects the device from transport damage. The packaging materials are selected according to environmentally compatible and disposal aspects, which makes them recyclable. The corrugated cardboard/paperboard is mainly made of waste paper. The styrofoam moldings are foamed CFC-free. The polyethylene film (PE) consists partly of secondary raw material. The strapping bands are made of polypropylene (PP). The return of the packaging to the material cycle saves raw materials and reduces waste generation. Your dealer will generally take back the packaging. If you dispose of the transport packaging yourself, please ask for the address of the nearest recyclables or recycling center.

Page 5 of the Oranier Artemis user manual — Operation
Page 5 · click to enlarge
Page 5

Operation

Precautionary statements

  • The space heater shall not be covered or delivered. Also, no combustible objects may be placed in front of the heater. Vinyl wallpaper in the region of the heater is unsuitable.

The installation may only be carried out by a professional (contract installer of a gas supply company). This takes responsibility for the proper installation and for first commissioning.

  • During operation of large-area and/or highly heated heating devices, decomposition of adhering organic dust particles can occur and thus anomalously strong contamination of the rooms in question. Please avoid furnishing the rooms with textiles too richly, especially large-scale fluffy carpets.
  • The apparatus shall be operated only in a sufficiently ventilated space.
  • Subsequent structural changes to the operating space that affect the supply of sufficient combustion air can have dangerous consequences.
  • Shelves or curtains placed above the heater shall be at least 250 mm apart.
  • The surface of the space heater cladding and especially that of the heat exchanger become very hot.
  • Articles of combustible construction materials placed in the radiant region upstream from the heater shall have a minimum clearance of 500 mm.
  • Make young children and old and infirm people aware of the danger of burning and keep away from the heater!
  • The entire cladding of the space heater, including any windows that may be present, is designed as a working or operating unit according to the test standard. functional surface.
  • Do not operate the device without ensuring that children cannot play with it. The safety measures which are of course available do not always cover accident possibilities in this regard.
  • This guide is part of the device. If the device is passed on in any form, this instructions must also be passed on.
  • When these heaters are installed in schools, kindergartens or other places where o. g If you can also stop people unattended, we recommend that additional protective screens with a sufficiently large outlet cross section for the convection heat be installed.
  • No clothing (e.g.) Put shoes or textiles) on the heater to dry!

6-99.03.12.000 - 002 5

Page 6 of the Oranier Artemis user manual — Location of controls
Page 6 · click to enlarge
Page 6

Instrument description

They have become owners of a space heater in which the latest heating technology combines with the stimulation of a wood fire. The gas valve used has a regulation modulating between maximum and minimum power.

If the heat requirement is below the minimum heating power, the valve switches off the main burner completely except for the ignition burner. Regardless of the thermostatic control of the gas valve, you have the possibility to adjust the heating power manually. The thermostatic control is then out of operation.

Equipment

Oranier Artemis — Equipment diagram (page 6)
Fig. 1 · Equipment
Oranier Artemis — Equipment diagram (page 6)
Fig. 2 · Equipment

Model Vertico, Type 60-81

Model Lithorond, type 60-82

  • Fuel-bound device with thermostatic exhaust gas monitor. Design B11, BS .
  • Gas valve

– to start and decommission the device.

– with a built-in thermostat to achieve an even room temperature.

  • Standard basic unit with integrated back-current fuse and three different trim variants.

– with thermoelectric safety valve for protection against the outflow of unburned gas.

  • Large viewing window held in a metal frame and screwed to the combustion chamber.

– with built-in pressure regulator for the exact adjustment of nominal thermal load.

  • Flat burner, with wood and coal imitation arranged above it for the purpose of simulating a wood fire.
  • piezoelectric igniter for ignition of the ignition flame.

Location of controls

A Operating button 1* and Pressure button for piezzo ignition 2* B All-gas valve with: Power slider 3*

* These designations and numbers are used on page 7 for the control panels.

6 6-99.03.12.000 - 002

Page 7 of the Oranier Artemis user manual — Decommissioning
Page 7 · click to enlarge
Page 7

Entry into service

Adjustments

Open the gas tap.

Thermostatic control The power slider 3 on the all-gas valve B in positions (standard setting). The thermostat installed in the all-gas valve automatically regulates the room temperature, which is controlled by means of the control button. 1 is set. The specified digits characterize the control range of the thermostat. After a short time, you will have determined which setting corresponds to your need for heat. Living location and construction of the house, the size of the room as well as its heat loss affect this. Therefore, only indicative values can be specified at the factory which may deviate downwards or upwards. For an average room temperature of 20°-22° C., the setting 3 to 4 of the operating button should be appropriate. Higher numbers correspond to higher temperatures, lower numbers correspond with lower temperatures. The power, i.e. The flame size of the burner is automatically increased or reduced, depending on heat requirements and sliding continuously between the small-fire position and full-burning position. If the heat supply of the small position exceeds the requirements of the room, the thermostat switches off the gas feed up to the ignition flame. When the heat demand is renewed, it opens up its small position in order to automatically adapt itself to requirements. It may therefore be the case that, in position 3 with throttled power, or in a small position, the space heater burns only because the desired temperature has already been reached in the room. On the other hand, it is possible for this to burn at full power in position 1, because the room has a temperature of only approx. 10 °C or less. This control reduces ignition and operating noise to a minimum compared with other heating systems. During the setting, only the ignition flame burns and the control is overridden. However, the heat of the ignition flame is retained in space as basic heat.

– Operating button 1 rotate and press in the ignition position.

– Pressure button 2 for the piezzo ignition to ignite the ignition flame, press in several times until the ionic flame burns. Operating button 1 Approximately Hold in for 10 seconds.

– Operating button 1 Let go. If the ignition flame is extinguished, the illusion process may be repeated only after a waiting time of 3 minutes.

– If the ignition flame burns, temperature selection can be made. For this purpose, the operating button 1 For example, turn to the number 4.

If the temperature attained does not correspond to your wishes, you can increase the temperature by setting it to a higher number or lower the temperature through setting it up to a smaller number. For the night, turn the control button 1 to a smaller number or, if only the ignition flame is intended to burn, to the symbol .

In case of ignition difficulties, see the chapter ‘Incident assistance’.

Decommissioning

For a short time – Operating button 1 Turn to the right, beyond the ignition position until it stops.

For longer periods – In the event of a prolonged interruption in operation, additionally close the gas connection valve.

After the shutdown, the space heater cannot be immediately put back into operation (re-switching block). A waiting time of approx. 60 seconds to be taken.

Manual scheme The thermostatic control is set out of force when the power slider 3 on the all-gas valve B from the standard setting ( ). The further the power slider is shifted from the position, the greater the set line or output of the circuit breaker. Flame size. With the operating button 1 The device can now no longer be regulated, but still switched off. In order to restore thermostatic control, conductor slide 3 Bring it back into position.

In the event of faults which cannot be eliminated themselves (see chapter “Incident Assistance”), the device must be taken out of operation until a specialist has resolved the problem.

6-99.03.12.000 - 002 7

Page 8 of the Oranier Artemis user manual — Exhaust monitoring device
Page 8 · click to enlarge
Page 8

Energy-saving heating

  • To save energy, the temperature should be lowered at night by adjusting the operating button.
  • If the windows are opened for a longer time to ventilate the installation room, the operating button should be rotated on 1 or.

Cleaning, care

During regular cleaning of the apartment, dust should also be removed from the heater. This avoids unnatural contamination of the room, as can occur in rooms with upholstered clothing and carpets due to abrasion of wool and cellulose which enter into the heater's convection stream as floating bodies. Care for stone surfaces regularly with suitable, commercially available care agents.

Exhaust monitoring device

Function The space heaters are equipped with an exhaust gas monitoring device. This ensures that, in the event of a malfunction in exhaust gas discharge, no large quantities of exhaust gases can pass through the flow control into the installation space. In the event that the exhaust gas cannot be discharged unhindered through the chimney, a temperature sensor is heated by the exhaust which exits from the flow control and the supply of gas is interrupted after a delay time. In full-load operation of the heater, the deceleration time is a few seconds.

Restart of operations In order to be able to restart the heater after exhaust gas monitoring, wait a few minutes for the temperature sensor to cool down. In addition, it shall be ensured that the exhaust duct (pipe, chimney) is not blocked or obstructed at any point. The start-up can then take place as described above.

If the exhaust gas monitoring device should respond, a person skilled in the art must be able to check the apparatus or control system. the exhaust gas dissipation system.

8 6-99.03.12.000 - 002

Page 9 of the Oranier Artemis user manual — Incident assistance
Page 9 · click to enlarge
Page 9

Maintenance

Regular maintenance of the space heater ensures its operational reliability. We therefore do not recommend that the function of the gas fitting and burner system, the leakage properties of the parts carrying gases, the adjustment to the gas and the correct discharge of exhaust gases be checked every one or two years by a known contract installer. For all maintenance work, only original parts of the manufacturer shall be used. Repairs to the gas fitting shall be limited to substitution of assemblies. The opening of the gas fitting shall not be permitted.

Maintenance of the exhaust flap The exhaust flap shall be subjected to a functional test during the maintenance work at the gas fireplace and, if necessary, cleansing of dirt. For this purpose, the complete exhaust gas flap is kept under flowing water. In the case of severe greasy turbidity, the exhaust flap should be placed in a water bath containing hot fat-dissolving alkali (dishwashing detergent) and subsequently washed off with clear water. In no case should the cleaning be carried out mechanically, since there is a risk of permanent deformation of the control elements.

If a viewing window which is possibly in the process of being broken or if it has cracks, the space heater must not be put into operation until the viewing opening is renewed and the combustion chamber closed again.

Incident assistance

Before calling customer service, check if you can fix the fault yourself based on the following information.

DisturbancePossible causeRemedy The space heater (ignition burner) does not ignite.The appliance connection valve is closed.Open the appliance connection valve. air in the gas pipeline. (after prolonged interruptions in operation or after reconnection of the device)hold the operating button pressed for a longer time in ignition position. Then repeat the ignition process. plug of the ignition cable.plug-in. Repeat the ignition process. In this case, observe the skipping of the spark at the ignition burner. Ignition flame burns. After the operating button has been released, it immediately goes out again.operating button is not pressed in long enough until the end stop.Repeat the ignition after 3 minutes. Press the control button for at least 10 seconds. The device cracks or crackles during operation.Normal heating and cooling noises of the device.Continuous heating. (even level)
  • If you nevertheless use customer service for one of the listed notices or due to incorrect operation, the visit of the customer support technician cannot be free of charge even during the warranty period.
  • Therefore, you should consistently follow our operating instructions in this guide as well as our recommendations and suggestions.

6-99.03.12.000 - 002 9

Page 10 of the Oranier Artemis user manual — Installation manual
Page 10 · click to enlarge
Page 10

Installation manual

Precautionary statements

Instructions for the establishment

Installation may be carried out only by a professional

  • Before installation, check whether the local connection conditions (gas type and pressure) are in accordance with the equipment settings. In case of deviations, the device must be changed accordingly!

(contract installer of a gas supply company). This takes responsibility for the proper installation and for first commissioning.

  • The apparatus shall be operated only in a sufficiently ventilated space.
  • Before installation, check whether the local connection conditions (gas type and pressure) are in accordance with the equipment settings. In case of deviations, the device must be changed accordingly!
  • When the device and a mechanical venting means (e.g., e.g, are operated simultaneously) The range hood, tumble drier) in the installation space of the gas chamber heater shall be such that no higher vacuum is generated than 4 Pa (0.04 mbar) compared to atmosphere (see DVGW worksheet G 670).
  • Before installation, the opinion of the responsible district chimney master and gas supply company (GVU) should be obtained.
  • The installation of the heater in explosive and fire-prone rooms and garages is not permitted.
  • Subsequent structural changes to the operating space that affect the supply of sufficient combustion air can have dangerous consequences.
  • The wall distances specified in the section ‘dimensions’ on page 11 shall be observed.
  • When connecting to the gas network, in particular the relevant regulations and guidelines of the institutions of the country where the device is operated must be observed. These are, for example:
  • In order to reduce the distances from combustible or sensitive building materials, a ventilated protection made of non-combustable material against thermal radiation can be mounted as shown in the figure.
  • DVGW-TRGI (Technical rules for gas installations) in its current version
  • TRF (Technical rules Liquefied Gas) as amended
  • The respective Land Building Code
  • the firing ordinance (FeuVO) of the respective federal state.
  • According to the new FeuVO, gas furnaces or fuel lines immediately in front of these gas furening sites must be equipped with a device which automatically shuts off the further supply of gas (so-called “gas”) in case of fire (temperature greater than 100° C.). ‘Thermal valve fuse’.

Example of ventilated protection against thermal radiation

It must be ensured that the surfaces of components located behind the ventilated protection cannot have temperatures higher than 80 °C.

Installation rules for Austria • When installing the device in Austria, ÖVGW guidelines G1 (TR-Gas) and G2 (TRF LPG) must be observed.

  • In Austria, the heater may only be operated with natural gas H (= device setting Natural Gas E) and propane gas 50 mbar.

Installation regulations for Switzerland • SVGW gas guideline G1 (2005): Gas installation

  • EKAS Directive No. 1942 (EKAS: Swiss Federal Coordination Commission for Occupational Safety)
  • Regulations of cantonal authorities (e.g. Fire protection) must also be observed.

10 6-99.03.12.000 - 002

for Germany · Non-combustible material

Page 11 of the Oranier Artemis user manual — Assembly
Page 11 · click to enlarge
Page 11
  • Shelves or curtains placed above the heater shall be at least 250 mm apart. Articles of combustible construction materials placed in the radiant region upstream from the heater shall have a minimum clearance of 500 mm.
Oranier Artemis — Assembly diagram (page 11)
Fig. 3 · Assembly
Oranier Artemis — Assembly diagram (page 11)
Fig. 4 · Assembly

Distances from combustible articles

  • In the case of very sensitive floors, a corresponding heat protection plate should be installed under and in front of the room heater (up to approx. 300 mm in front of the heater. This is not a fire protection requirement, as temperatures in this range are below 85 °C.

Model Lithorond, type 60-82

  • The entire cladding of the space heater, including any windows that may be present, is designed as a working or operating unit according to the test standard. functional surface.

The distance from the device rear wall to the positioning-

The wall shall be at least 100 mm.

Assembly

Oranier Artemis — Assembly diagram (page 11)
Fig. 5 · Assembly

Model Vertico, Type 60-81

6-99.03.12.000 - 002 11

Dimensions

Page 12 of the Oranier Artemis user manual — Assembly
Page 12 · click to enlarge
Page 12

Installation of the basic equipment At this point, only the setup of the basic device will be discussed. The assembly of the cladding is described separately. – Set up the basic device horizontally at its intended location, taking into account the specified fairing dimensions. Ground irregularities can be compensated by the screw feet.

Functional test of the exhaust flap After the exhaust flap has been installed in the gas control site, a functional test of the entire exhaust system shall be carried out as described in paragraph 8.3 of TRGI 1986/96. At each gas firing site, it shall be ascertained 5 minutes after operation with the windows and doors of the dwelling closed that no exhaust is leaking at the flow control. In the case of several fire stations installed in the dwelling, this test shall be carried out with all gas-firing points operating simultaneously both when the interior doors are closed and open. This test shall be carried out at the highest thermal output with which gas furnaces can operate, and also at the lowest heat load in the case of a gas furencing to be tested. If exhaust gas leaks during the test, no single-wall operation is ensured. The cause must be determined immediately, the defects are to be confirmed.

– Connect the space heater with the gas pipe and exhaust gas tube.

The space heater must be tilt-proof on the wall

are fixed:

– Screw the threaded rod accompanying the device into one of the screw holes present at the top in the rear wall of the device.

– A hexagon nut is first screwed onto the wall-side end of the threaded rod, and then the holding plate.

– Indicate the position of the holding plate on the wall.

Gas connection When connecting the gas line, it is absolutely essential to hold against the connection piece in a suitable manner. After installation, all connections shall be checked for leakage. The appliance connection faucet shall be mounted in a readily accessible position outside the equipment lining.

– Screw the holding plate with the attached fastening material on the wall. If the wall is of a special nature, the holding plate must be adjusted in another suitable manner.

– Finally, the threaded rod with the hexagon nut must be secured against rotation.

Insertion of the coal and wood imitation When the cladding is removed

In order to prevent the imitation arranged according to the specifications e.g. by moving the device, the construction of the imitation pieces must not take place until the space heater is connected on the gas side and off-gas side.

Remove the imitation material placed packed in the combustion chamber of the space heater. For this purpose, the viewing window must first be removed:

The mother accessible in the pictured opening X unscrew and remove the washer.

Connection of the exhaust pipe The connection of an all-gas space heater to a fireplace is in accordance with TRGI 1986/96 or TRF 1996 is increasing. In any case, the competent district chimney sweep master should be consulted.

Oranier Artemis — Assembly diagram (page 12)
Fig. 6 · Assembly
  • Care must be taken to insert the exhaust pipe into the nozzle of the appliance.
  • The exhaust pipe from the heater to the chimney should be as short as possible.
  • A long exhaust pipe can lead to the formation of condensation water and thus under unfavorable circumstances to a chimney sooting.

– Tilt the viewing window with frame forward and lift it from lower locking

  • If a HOS 80 exhaust flap is used (mandatory if the chimney has mixed content), it shall be inserted into the space heater’s gas inlet.

– Put aside windows with frame.

The packaging contains:

  • 6 pieces of wood imitation
  • 4 Coal Imitations
  • 1 bag of granules

12 6-99.03.12.000 - 002

Page 13 of the Oranier Artemis user manual — Assembly
Page 13 · click to enlarge
Page 13
4. Step – Place the two depicted, rear wooden imitation pieces* one after another against the combustion chamber back wall. The projecting branch of the right wooden imitation piece should come to rest in the trough present in the previously inserted imitation pieces. Where applicable set up the front imitation piece accordingly. (* if applicable) whether or not made in one piece
1. Step – deposit coal imitation on the wire grid, taking into account the specified dimensions. The second imitation piece from the right should be arranged obliquely (corresponding to the right branch piece disposed in step 4).
Oranier Artemis — Assembly diagram (page 13)
Fig. 7 · Assembly
Oranier Artemis — Assembly diagram (page 13)
Fig. 8 · Assembly
2. Step – Place the granules packed in a bag on the remaining grid surface.
5. Step – Insert the imaged, middle wooden imitation piece so that the branches rest on both rear imitations.
Oranier Artemis — Assembly diagram (page 13)
Fig. 9 · Assembly
Oranier Artemis — Assembly diagram (page 13)
Fig. 10 · Assembly
3. Step – Place the pictured front wooden imitation piece with its unstructured side on the floor of the combustion chamber and against the boundary fence. In this case, care must be taken that no granulate parts are located between the ignition flame and thermocouple.
6. Step – Place the two depicted lateral wooden imitation pieces (identical shape), as shown on the combustion chamber walls and on the rear imitations.
Oranier Artemis — Assembly diagram (page 13)
Fig. 11 · Assembly
Oranier Artemis — Assembly diagram (page 13)
Fig. 12 · Assembly

Closing the combustion chamber – Pick up the viewing window with frame and clean the inside of the window.

– Plug in frames at the bottom, press on top and with previously removed mother With washers underpinned screwed back onto the combustion chamber. In this case, make sure that the frame rests tightly on top.

6-99.03.12.000 - 002 13

Inserting the parts

Page 14 of the Oranier Artemis user manual — Gas setting
Page 14 · click to enlarge
Page 14

Gas setting

Adjustment order All points strictly in the specified sequence.

The factory gas setting is specified on the type of gas adhesive.

1. Control of the connection flow pressure – close appliance valve.

At the installation site, it is essential to check whether local connection conditions, type of gas and pressure are in accordance with the device settings on the basis of information on the equipment labels.

Remove the sealing screw "1".

Connect the pressure gauge to the measuring nozzle "2".

If necessary, a changeover of equipment to this type of gas is required (see ‘changeover to another type of Gas’).

Open the appliance tap.

– put the device into operation and measure the flow pressure in full fire (if applicable). cool the heat sensor in the water bath. The flow pressure must lie within the specified range. If this is not the case, no setting or entry into service shall be carried out. The gas supply unit or the reservoir, i.e. the LPG supplier shall be corrected.

The verification and, if applicable, The correction of the gas input (rated heat load) is carried out either by nozzle pressure method or volumetric metering (for natural gas only). As a rule, the nozzle pressure method is preferred since it is sufficiently accurate and very time-saving.

– Take the device out of service and close the appliance tap.

Types of gas • With the natural gas setting E-G20 (H-G 20), gas appliances can be operated in the Wobbe index range from 11.3 to 15.2 kWh/m3 *.

– Remove the pressure gauge from the measuring nozzle “2” and seal the measuring tube “2“ gas-tight again with sealing screw “1”.

  • With the LL-G 25 natural gas setting, gas appliances can be operated in the Wobbe index range from 9.5 to 12.4 kWh/m 3 *. Whether your device can be converted to natural gas LL-G 25 please refer to the technical data.
Oranier Artemis — Gas setting diagram (page 14)
Fig. 13 · Gas setting
Oranier Artemis — Gas setting diagram (page 14)
Fig. 14 · Gas setting

*relative to 15° C., 1013 mbar

Gasart and Wobbeindex are to be requested from the gas supply company.

  • Propane gas I3P - G31 - 50 mbar

A change of equipment to another gas-

Family is not allowed!

Subsequent flow pressure natural gas17.0 mbar - 25.0 mbar

Open the appliance tap.

Propane gas42.5 mbar - 57.5 mbar

If the permissible subsequent flow pressure is exceeded,

or undershot, the device must not be put into operation! The gas supplier or The tail gas supplier shall be notified.

14 6-99.03.12.000 - 002

Connection conditions · Sit valve

Page 15 of the Oranier Artemis user manual — Gas setting
Page 15 · click to enlarge
Page 15
2. Adjust nominal thermal loading by means of nozzle pressure method – close the appliance connection valve.

sufficient heating in each operating position and to ensure a reliable over-ignition. The ignition flame load is determined by the ignition burner nozzle. If the heating of the thermocouple and a safe over-ignition are no longer ensured, cleaning or possibly also replacement of the ignition burner nozzle must be carried out. An excessively large ignition flame can be readjusted with the "7" setscrew. The adjusting screw shall be screwed in at least one thread (one revolution).

– Remove the sealing screw “3” and connect the pressure measuring device to the metering nozzle “4”.

Open the appliance tap.

– put space heater into operation according to the user’s instructions.

– Turn the operating button to its highest position (if applicable). Cool the heat sensor in a water bath.

– Adjust nozzle pressure according to the adjustment table with the control screw "5".

– Take the device out of service and close the appliance tap.

– Remove the pressure gauge from the measuring nozzle “4” and close the measuring tube “4“ again with a sealing screw “3” gas-tight.

Functional test All connections shall be checked for leakage.

Open the appliance tap.

- Mount the cladding.

– Ignition and main burners, checking combustion stability at large and small positions.

By volumetric method (only for natural gas) – put space heater into operation according to the user’s instructions.

– After completion of the work, this instruction must be handed over to the customer. The customer must be informed about the operation, correct handling and safety devices of the device.

– Take other gas consumers out of service.

– Turn the operating button to its highest position (if applicable). Cool the heat sensor in a water bath.

After an operating time of 10 minutes, determine the gas consumption over a period of 5 minutes (read on the gas clock).

  • The exhaust gas monitoring device shall not be adjusted or modified by the installer, unless this guidance specifically requires such work during installation.

– Compare actual gas consumption with the target value specified in section “Technical data”.

– If necessary, adjust the gas consumption with control screw "5" and check the gas use again.

  • The exhaust gas monitoring device shall not be deactivated.
3. Set small setting thermal load – turn the operating button slowly to the right until the flames of the main burner go out. The switching point “small – off” is thus determined. If the flames do not go out in their smallest position, the room temperature is too low. The temperature sensor shall then be heated either until sufficient heating is achieved or it must not exceed 20 °C in a water bath.
  • When the exhaust gas monitoring device or components thereof are replaced, only original parts of the manufacturer shall be used.

– Now turn the control button slowly to the left until the burner flames are re-burning. The main burner now burns in the small position. It must be ensured that a satisfactory over-ignition is guaranteed in all cases. Using the nozzle size specified in the section “Technical data”, this is the case with a small adjustment screw that has been turned into an impact.

– If necessary, adjust the small position with the small adjustment screw "6" (left rotation increased, right-hand rotation reduced gas passage).

4. The ignition flame must be large enough to allow the thermal

6-99.03.12.000 - 002 15

Page 16 of the Oranier Artemis user manual — After the nozzle has been replaced
Page 16 · click to enlarge
Page 16

Conversion to another type of gas

Switching the device to another gas family (natural gas to propane and vice versa) is not permitted.

Conversion to another natural gas category

The gas changeover shall be carried out only by an

can be carried out by a person skilled in the art.

Only customer service related

special nozzles are used.

rich, the heater may only be operated with natural gas H (= device setting Natural Gas E).

Nozzle sets The available nozzle sets and their order numbers can be found in the technical data.

– Close the gas tap.

- Take off the disguise. The removal of the cladding is effected in a change to the sequence contained in separate assembly instructions.

Remove shielding and holding plate "8". For this purpose, unscrew the two screws "9", suspend the holding plate if necessary at the rear and remove it by pulling forward.

Remove the window:

– For this, the mother accessible in the depicted opening X unscrew and remove the washer.

– Remove the pipe clamp “11” and pull the nozzle stick “12” downwards from the injector “10”.

– Change the main burner nozzle “13”, countering it in a friendly manner.

The jet stick again Up to the stop plug into the injector and secure it with a pipe clamp.

– Reassemble the holding plate “8” and cladding.

– Closing the combustion chamber:

– To do this, pick up the viewing window with a frame and clean the inside of the window.

– Move the viewing window with frame forward and lift it from lower locking

– Plug in frames at the bottom, press on top and with previously removed mother With washer underlay screwed back onto the combustion chamber. In this case, make sure that the frame rests tightly on top.

– Put aside windows with frame.

– Control nozzle pressure (rated thermal load) and adjust it if necessary (see “Technical data”).

The setting of the small position and that of the ignition burner remain unchanged!

After the nozzle has been replaced

– Stick attached stickers to the previous gas-art sticker.

– Perform leakage testing.

– Control the subsequent flow pressure.

- Mount the cladding.

16 6-99.03.12.000 - 002

Replacement of the main burner nozzle

Page 17 of the Oranier Artemis user manual — SIT 25
Page 17 · click to enlarge
Page 17

Technical data

(=device setting natural gas E) and liquefied petroleum gas 50 mbar.

Type series 60-8X Type Series 60-8x P

Natural gas thread R 1⁄2" 1⁄2, 8 mm

Exhaust connection Ø 80 mm

Exhaust gas temperature 190 °C 177 °C

Exhaust gas mass flow rate 5.83 g/s 5.1 g/ s

CO2 content 4.1 vol.% 4.3 vol. %

Exhaust flap, thermally controlled type HOS 80

Rated heat output Rated thermal load (relative to calorific value Hi)

5,0 kW 6,1 kW 4.2 kW 5.1 kW

Nozzle table and nozzle sets

Gasart Type Series 60-8X Typeseries 60-8X P

Main burner nozzle characteristic number * 215 / 16 mm long

Natural gas E 20 mbar (G 20) AT, CH: H 20 mbar Wobbe index range Ws = 11,3 – 15,2 kWh/m3

Small adjustment screw characteristic number * 170

SIT 36

Order number of nozzles 5-54.00.00.000

Main burner nozzle characteristic number * 235 / 22.5 mm long

Natural gas LL 20 mbar (G 25) only DE Wobbe index range Ws = 9.5 – 12.4 kWh/m3

Small adjustment screw characteristic number * 170

SIT 36

Order number of nozzles 5-54.00.01000

105 / 16 mm long

Small adjustment screw characteristic number * 90

Propane (G 31) 50 mbar

SIT 25

* nozzle diameter in hundredths of a millimeter (e.g. 240 = Ø 2,4 mm

6-99.03.12.000 - 002 17

Show 17 more labels / short text on this page
Product identification number CE-0085BM0493 · Feed pressure 5.0 Pa · Net weight kg · No changeover · Ignition nozzle characteristic number · Permitted! · Junkers 48 · No changeover · Ignition nozzle characteristic number · Permitted! · Junkers 48 · Main burner nozzle characteristic number * · No changeover · Ignition nozzle characteristic number · Permitted! · Junkers 42 · Jet Set Order Number –
Page 18 of the Oranier Artemis user manual — NO x concentration limits (according to EN 613)
Page 18 · click to enlarge
Page 18

Adjustment table for nozzle pressure and gas flow

Gasart Type Series 60-8X Typeseries 60-8X P

Natural gas E 20 mbar (G 20)

0,645 m3/h

Calorific value Hi = 34,02 MJ/m3 Wobbeindex Ws = 50,72 MJ / m3

Natural gas LL 20 mbar (G 25) only DE calorific value Hi = 29.25 MJ/m3 Wobbeindex Ws = 41.52 MJ / m3

0,751 m3/h

Propane 50 mbar (G 31) calorific value Hi = 46.26 MJ/m3 Wobbeindex Ws = 76.84 MJ / m3

0,397 kg/h flow rate of gas

All figures for the calorific value Hi, Wobbeindex Ws and the connection value (flow rate) refer to 15 °C, 1013 mbar, dry gas.

NO x concentration limits (according to EN 613)

Categories NOx mg/kWh

1 2 3 4 5

350 260 200 150 100

  • The 60-8X range heaters correspond to the NO x class 5.

18 6-99.03.12.000 - 002

Show 7 more labels / short text on this page
Nozzle pressure 11.8 mbar · Flow rate of gas · 10.75 l/min · nozzle pressure 12.8 mbar • flow rate of Gas · 12.52 l/minute · nozzle
Page 19 of the Oranier Artemis user manual — Orange – Works Guarantee
Page 19 · click to enlarge
Page 19

Orange – Works Guarantee

In order to claim guarantees, the presentation of proof of purchase is required in each case.

6. We are not liable for damages and defects to devices and their parts caused by:

For our ORANIER devices, we provide a factory guarantee regardless of the obligations of the dealer under the purchase contract vis-à-vis the final customer under these conditions:

– External chemical or physical effects

during transport, storage, installation and use (e.g. Damage caused by quenching with water, overflowing foods, condensation and superheating. Hair cracking in enamelled or tile-glazed parts is not a quality defect.

The ORANIER guarantee covers the irrevocable repair of the device or of the parts covered. A claim for free replacement is only valid for those parts which have defects in the material and processing.

- Wrong size choice.

- Non-compliance with our installation and operation

instructions, the applicable building law general and local regulations of competent authorities, gas and electricity suppliers. This also includes elements on the exhaust pipes (furnace tube, inadequate or excessively heavy chimney draw) as well as improper maintenance work carried out, especially making changes to the equipment, its fittings and lines.

All direct labour and material costs incurred to eliminate this situation are taken over. Further claims are excluded.

1. The work guarantee is 24 months and starts from the time of delivery, which must be proven by invoice or delivery note.

– Use of unsuitable fuels in coal-fired

2. Within the factory warranty, all functional defects which are demonstrably due to manufacturing or material defect despite proper connection, appropriate treatment and compliance with valid ORANIERE installation regulations and operating instructions will be eliminated by our customer service. Enamel and paint damages are only covered by this factory warranty if they are reported to our customer service within 2 weeks of handover of the ORANIER device. Transport damage (which must be claimed against the transporter in accordance with the conditions of the carrier) as well as adjustment, adjustment and conversion work on gas consumption equipment are not covered by this factory guarantee.

equipment fired and fuel oil; inappropriate gas quality and variations of gas pressure for appliances; unusual voltage fluctuations compared to the nominal voltage for electrical appliances.

– Incorrect operation and overload, and therefore

overheating of the equipment, improper treatment, insufficient care, inadequate cleaning of the machinery or its parts; use of unsuitable cleaners (see operating instructions).

– wear of the flames immediately

used parts of iron and fireclay (e.g. Steel, cast or fireclay liners.

We are not liable for indirect and immediate damage caused by the devices. This also includes room contamination caused by decomposition products of organic dust components and whose pyrolysis products can be deposited as a dark coating on wallpaper, furniture, textiles and furnace parts.

3. By claiming the factory warranty, the guarantee period is not extended for either ORANIER equipment or newly installed parts. Replaced parts will become our property.
4. The location, type and extent of the repair to be carried out or a replacement of the device is decided by our customer service at reasonable discretion. Unless otherwise agreed, our customer service centre must be notified. The repair is usually carried out at the site, exceptionally in the customer service workshop. Equipment for repair must be made accessible in such a way that no damage to furniture, flooring etc. may arise.

If the removal of a defect is not covered by our warranty, then the final customer must pay for the costs of the installation visit and repair.

ORANIER Heiz- und Kochtechnik GmbH Weidenhäuser Str. 1 – 7 35075 Gladenbach

5. The spare parts required for repair and the working time incurred are not charged.

6-99.03.12.000 - 002 19

Page 20 of the Oranier Artemis user manual — KOCHTECHNIK HEIZUNGTECHNIK
Page 20 · click to enlarge
Page 20

Heating and cooking technology since 1915

3 x Competence and constantly new ideas

Oranier Artemis — Heating and cooking technology since 1915 diagram (page 20)
Fig. 15 · Heating and cooking technology since 1915

KOCHTECHNIK HEIZUNGTECHNIK

O Gas stoves with remote control

O Wood and coal permanent fire furnaces

Oranier Artemis — KOCHTECHNIK HEIZUNGTECHNIK diagram (page 20)
Fig. 16

O Installation stove gas or electric

O Installation cooking fields Gas and Electric

O Standing gas and electric

Oranier Artemis — KOCHTECHNIK HEIZUNGTECHNIK diagram (page 20)
Fig. 17

incl. heat exchanger;

6-99.03.12.000

ORANIER Heiz- und Kochtechnik GmbH. Weidenhäuser Str. 1-7. 35075 Gladenbach

Tel.: 06462-923-0 . Fax: 06462-923-349 . Email: info@Oranier.com

ww w . O r a n i e r c o m

Show 10 more labels / short text on this page
O Fireplace furnaces · O Automatic gas heaters · O Gourmet cooking baking stations · O range-of-vapor hoods · O Refrigerators and freezers · O Automatic dishwashers · O modulAIR · Controlled ventilation and deaeration · humidification module; and · Sticking-story circuit

Ask about the Oranier Artemis

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Oranier Artemis

Be the first to ask — other owners or our team will answer.

Original document

Oranier Artemis manual PDF

20 pages·2.3 MB·Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…