I NTRODUCTION
The SuperStack® 3 Baseline 8 Port Gigabit Switch is a versatile, easy-to-use switch. It is ideal for users who want the high-speed performance of 10/100/1000 switching but do not need sophisticated management capabilities. The Baseline 8 Port Gigabit Switch is shipped ready for use. No configuration is necessary.
The Baseline 8 Port Gigabit Switch supports a maximum of 8192 MAC adddresses.

The Baseline 8 Port Gigabit Switch can be rack-mounted or free standing.
The Baseline 8 Port Gigabit Switch includes:
One power cord
One mounting kit
Four standard height, self-adhesive rubber pads
The Switch is powered from the AC mains supply.
The Baseline 8 Port Gigabit Switch provides high performance switched connections to 10 Mbps, 100 Mbps, and 1000 Mbps hubs, switches, servers and workstations that need a dedicated switched link. The following figure illustrates one possible configuration. The Baseline 8 Port Gigabit Switch has 8 shielded RJ-45, 10/100/1000 Mbps auto-negotiating ports on the front panel. Each 10/100/1000 Mbps port automatically determines the speed, duplex mode, and MDIX mode of the connected equipment and provides a suitable switched connection. The 10/100 Mbps connections on these 1000BASE-T ports operate in half or full duplex mode while the 1000 Mbps connections operate in full duplex mode.


FEATURES OF THE BASELINE 8 PORT GIGABIT SWITCH
The numbers in this diagram refer to numbered sections in the text.
CAUTION: The Baseline 8 Port Gigabit Switch supports full duplex auto-negotiation. If the connected device does not support auto-negotiation, the Switch will operate in half duplex mode (only for 10BASE-T and 100BASE-TX). In such a configuration, you may notice some degradation of network performance. 3Com recommends that you use devices that are capable of auto-negotiation (and that you ensure that auto-negotiation is enabled, if it is a configurable option).
WARNING: RJ-45 ports. These are shielded RJ-45 data sockets. They cannot be used as standard traditional telephone sockets, or to connect the unit to a traditional PBX or public telephone network. Only connect RJ-45 data connectors, network telephony systems, or network telephones to these sockets. Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets. AVERTISSEMENT: Les ports RJ-45. Ceux-ci sont protégés par des prises de données. Ils ne peuvent pas être utilisés comme prises de téléphone conventionnelles standard, ni pour la connection de l’unité à un réseau téléphonique central privé ou public. Raccorder seulement connecteurs de données RJ-45, systèmes de réseaux de téléphonie ou téléphones de réseaux à ces prises. Il est possible de raccorder des câbles protégés ou non protégés avec des jacks protégés ou non protégés à ces prises de don. WARNUNG: RJ-45-Porte. Diese Porte sind geschützte Datensteckdosen. Sie dürfen weder wie normale traditionelle Telefonsteckdosen noch für die Verbindung der Einheit mit einem traditionellem privatem oder öffentlichem Telefonnetzwerk gebraucht werden. Nur RJ-45-Datenanscluße, Telefonnetzsysteme or Netztelefone an diese Steckdosen anschließen. Entweder geschützte oder ungeschützte Buchsen dürfen an diese Datensteckdosen angeschlossen werden.
All ports auto-sense an MDI/MDIX connection and can be used to connect to either another switch port, server, or workstation without additional configuration. Each port can be connected to a device with a normal ‘straight through’ TP (twisted pair) cable or a ‘cross-over’ TP cable.
The Switch offers priority queuing, which means all packets that are received are examined to see if they have been priority encoded. If a packet has been, then the Switch will read the priority level and determine whether the packet should be directed through the normal or high priority channel. This feature can be useful for example during excessive loads when one type of traffic may require priority over another. The Switch is configured to comply with 802.1p, VLAN tagged frames.
Traffic prioritization ensures that high priority data is forwarded through the Switch without being delayed by lower priority data. It differentiates traffic into classes and prioritizes those classes automatically. Traffic prioritization uses the multiple traffic queues that are present in the hardware of the Switch to ensure that high priority traffic is forwarded on a different queue from lower priority traffic, and is given preference over that traffic. This ensures that time-sensitive traffic gets the highest level of service. The 802.1D standard specifies eight distinct levels of priority (0 to 7), each of which relates to a particular type of traffic. The priority levels and their traffic types are shown in the following table.
The Baseline 8 Port Gigabit Switch has 8 10/100/1000 Mbps auto-negotiating ports. Each port automatically determines the correct speed and duplex mode as one of the following:
10BASE-T half duplex
10BASE-T full duplex
100BASE-TX half duplex
100BASE-TX full duplex
1000BASE-T full duplex

The second row of Status LEDs, which are colored yellow, show the duplex status of the related ports:
1000BASE-T only operates in full duplex mode. 10BASE-T/100BASE-TX can be in half or full duplex mode.
The traffic prioritization feature supported by the Switch is compatible with the relevant sections of the IEEE 802.1D standard (incorporating IEEE 802.1p).
The Power LED shows the power status of the Switch:
The top row of Status LEDs, labelled “Link/Activity,” show the link and activity status of the related ports:
The Baseline 8 Port Gigabit Switch automatically adjusts to the supply voltage. Only use the power cord that is supplied with the unit.
Rack Mounting or Free Standing This unit can be mounted in a 19-inch equipment rack using the Mounting Kit. Refer to “Mounting Kit Instructions” on page 4. It can also be free standing. Do not place objects on top of the unit or stack.
When deciding where to position the Baseline 8 Port Gigabit Switch ensure:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise. These include lift shafts, microwave ovens, and air conditioning units. Electromagnetic fields can interfere with the signals on copper cabling and introduce errors, therefore slowing down your network.
The unit is supplied with four self-adhesive rubber pads. If the unit is to be part of a free standing stack, apply the pads to each marked corner area on the underside of the unit. Place the unit on top of the lower unit, ensuring that the pads locate with the recesses of the lower unit.
Water or moisture cannot enter the case of the unit.
Do not apply the pads if you intend to rack mount the unit.
Air flow around the unit and through the vents in the side of the case is not restricted (3Com recommends that you provide a minimum of 25 mm (1 in.) clearance).
The air is as free from dust as possible.
Temperature operating limits are not likely to be exceeded. It is recommended that the unit is installed in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist strap when installing network equipment, connected to a ground point. If one is not available, try to keep in contact with a grounded rack and avoid touching the unit's ports and connectors, if possible. Static discharge can cause reliability problems in your equipment.

The unit is intended to be grounded. Ensure it is connected to earth ground during normal use. Grounding the unit helps to avoid damage from lightning and power surges.
Follow these guidelines to connect a device to the Baseline 8 Port Gigabit Switch:
Use Category 5 unshielded or shielded (screened) 100 Ohm TP cable (or Category 3 cable for a 10 Mbps connection).
Use the following sequence to power up the Baseline 8 Port Gigabit Switch:
The maximum length of cable for each connection is 100 m (328 ft).
1 Check the network connections and cables.
Connect one end of the cable to an RJ-45 port on the Baseline 8 Port Gigabit Switch, and the other end to the appropriate RJ-45 port on the connecting device.
2 Connect the power supply cable to the appropriate power socket on the rear panel of the unit; see reference 5 in “Features of the Baseline 8 Port Gigabit Switch.”
3 Connect the plug to the power supply outlet socket and switch on the power supply at the socket.
Power problems can be the cause of serious failures and downtime in your network. Ensure that the power input to your system is clean and free from sags and surges to avoid unforeseen network outages. 3Com recommends that you install power conditioning, especially in areas prone to black outs, power dips and electrical storms.
When the switch is powered on, the Power LED lights green. If it does not, see reference 4 in “Features of the Baseline 8 Port Gigabit Switch.”
3 Insert the two screws supplied in the mounting kit and fully tighten with a suitable screwdriver.
The Baseline 8 Port Gigabit Switch is supplied with two mounting brackets and four screws. These are used for rack mounting the unit. When mounting the unit, you should take note of the guidelines given in “Positioning the Switch” on page 3.
4 Repeat the two previous steps for the other side of the unit.
5 Insert the unit into the 19-inch rack and secure with suitable screws (not provided).
6 Reconnect all cables.

The Baseline 8 Port Gigabit Switch is 1U high and will fit a standard 19-inch rack.
1 Place the unit the right way up on a hard, flat surface with the front facing towards you.
2 Locate a mounting bracket over the mounting holes on one side of the unit (refer to the figure following step 6).
At frequent intervals you should visually check the Baseline 8 Port Gigabit Switch. Regular checks can give you an early warning of a possible failure; any problems can then be attended to when there will be least effect on users.
All Activity LEDs appear to be lit continually. There may be broadcast storms on the network. Remove port connections one at a time, waiting a few seconds between each port. If the LEDs go off after removing a port connection, the device that was connected to that port is introducing an excessive amount of broadcast frames to the network (some pieces of network equipment operate by sending out broadcast frames regularly). Refer to the documentation that accompanies the device for information on disabling the broadcast operation.
Check that all external cabling connections are secure and that no cables are pulled taut.
Refer to the information about LEDs given earlier in this guide to see if the problem can be identified and rectified. Here are some common problems that can occur:
If the problem persists and the unit still does not operate successfully, contact your supplier with the following information before returning the unit:
Activity Status LED not lit for a port that has a connection. There is a problem with this connection. Check that:
Product number and serial number (printed on a label sup- plied with the unit)
The device being connected to is powered on and operating correctly.
A brief description of the fault
The cable is connected at both ends.
You are using a TP cable that is not damaged.
If the connection is to a workstation, that the workstation’s network interface is installed and configured correctly.

Physical
The SuperStack 3 Baseline 8 Port Gigabit Switch has been designed to the following standards:
Width 440 mm (17.3 in.)
Depth 173 mm (6.8 in.)
Height 43.6 mm (1.7 in.) or 1U
Weight 3 kg (6.6 lb)
Functional ISO 8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast Ethernet), IEEE 802.3ab (Gigabit Ethernet), IEEE 802.1D (Bridging)
Mounting Free standing, or 19-inch rack mounted using the mounting kit supplied
Safety UL 60950, EN 60950, CSA 22.2 #60950, IEC 60950
EMC Emissions EN 55022 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A, CNS 13438 Class A
Power Inlet IEC 320
AC Line Frequency 47 to 63 Hz
Input Voltage 100–240 VAC
Current Rating 0.4 A at 115 V, 0.2 A at 230 V
28 W
Operating Temperature 0–40 °C (32–104 °F)
95.6 BTU/hr
CE Statement (Europe)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC/.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient the receiving antenna
Relocate the equipment in relation to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington,
DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.

The following options are available for technical support:
When you contact your network supplier for assistance, have the following information ready:
In the first instance contact your Network Supplier.
Check the 3Com knowledgebase at http://knowledgebase.3com.com
Product model name, part number, and serial number
A list of system hardware and software, including revision levels
Browse the 3Com web site on http://www.3com.com
Diagnostic error messages
If you require additional assistance, contact your network supplier. Many suppliers are authorized 3Com service partners who are qualified to provide a variety of services, including network planning, installation, hardware maintenance, application training, and support services.
Details about recent configuration changes, if applicable
If you are unable to contact your network supplier, see the following section on how to contact 3Com.

© 3Com Technologies, 2002. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without permission from 3Com Technologies.
For civilian agencies: Restricted Rights Legend: Use, reproduction or disclosure is subject to restrictions set forth in subparagraph (a) through (d) of the Commercial Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in 3Com Corporation’s standard commercial agreement for the software. Unpublished rights reserved under the copyright laws of the United States.
3Com Technologies reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Technologies to provide notification of such revision or change.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
3Com Technologies provides this documentation without warranty of any kind, either implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
UNITED STATES GOVERNMENT LEGENDS: If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following restricted rights:
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com and SuperStack are registered trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or trademarks of their respective holders.
For units of the Department of Defense: Restricted Rights Legend: Use, duplication or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) for restricted Rights in Technical Data and Computer Software clause at 48 C.F.R. 52.227-7013. 3Com Centre, Boundary Way, Maylands Park South, Hemel Hempstead, Herts, HP2 7YU, U.K.
End Of Life Statement
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Establishing environmental performance standards that comply with national legislation and regulations
3Com products do not contain any hazardous or ozone-depleting material.
Conserving energy, materials and natural resources in all operations
Environmental Statement about the Documentation
Reducing the waste generated by all operations
Ensuring that all waste conforms to recognized environmental standards
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradeable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and the inks are vegetable-based with a low heavy-metal content.
Maximizing the recyclable and reusable content of all products
Ensuring that all products can be recycled, reused and disposed of safely
Ensuring that all products are labelled according to recognized environmental standards
Improving our environmental record on a continual basis
You can now register your SuperStack 3 Baseline 8 Port Gigabit Switch on the 3Com web site:
http://support.3com.com/registration/frontpg.pl
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments about this document to 3Com at:
pddtechpubs_comments@3Com.com
Please include the following information when commenting: the document title, part number (shown at the bottom of this page), and page number, if appropriate.
General Environmental Statement · Regulated Materials Statement
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.