  • Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location.
  • Wipe up spilled gasoline at once.
  • Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building’s electrical system.
  • Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage.
  • Place the generator at least 1 m away from buildings or other equipment during operation.
  • Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
  • Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions.
  • Keep children and pets away from the generator when it is in operation.
  • Keep away from rotating parts while the generator is running.
  • The generator is a potential source of electrical shocks when misused; do not operate with wet hands.
  • Do not operate the generator in rain or snow and do not let it get wet.
  • WARNING: the warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
  • Only those persons who are aware of how to use the generator by having read this manual, should use the machine. Injudicious use may cause danger. 3. PRE-OPERATION CHECK Fuel tank capacity: 4 l. Use oil-mixed gasoline. If not, engine will be overheated. Do not fill above fuel filter top. How to make mixed gasoline. Gasoline and oil mixing ratio; 50:1 Use fuel tank cap to measure oil. Shake fuel tank before starting engine.
Page 3 of the Load Up 76010 - QFD 950 user manual
Page 3 · click to enlarge
Page 3
4. STARTING THE ENGINE Before starting, do not connect electric apparatus. 1. Turn fuel cock lever to "ON".
Page 4 of the Load Up 76010 - QFD 950 user manual
Page 4 · click to enlarge
Page 4
2. Turn chock lever to "1". 3. Turn engine switch to "ON". 4. Pull slowly on recoil starter until engaged, then pull it briskly. 5. Return chock lever. 5. STOPPING THE ENGINE 1. Before stopping, turn off electric apparatus.
Page 5 of the Load Up 76010 - QFD 950 user manual
Page 5 · click to enlarge
Page 5
2. Turn engine switch to "STOP". 3. Turn fuel cock lever to "OFF". 6. CONNECTION 1. Wind lead 2 or 3 turns around handle. 2. Start engine. 3. Plug into AC socket. SAFETY DEVICES Press to reset AC or DC protector.
Page 6 of the Load Up 76010 - QFD 950 user manual
Page 6 · click to enlarge
Page 6

Reduce load within rated output if AC or DC protector (if equipped) turns off. 1 = “ON” 2 = “OFF” 7. MAINTENANCE Item Remarks Every 50 hours or every month

Every 150 hours or every 3 months Spark plug

Remove carbon. Adjust gap. Replace if necessary.

Clean. Replace if necessary.

Clean. Replace if necessary.

Clean. Replace if necessary.

SPARK PLUG 1. Remove spark plug.

Show 7 more labels / short text on this page
▀ · Air filter · ▀ · Fuel filter · ▀ · Decabonigation · ▀
Page 7 of the Load Up 76010 - QFD 950 user manual
Page 7 · click to enlarge
Page 7
2. Remove carbon deposits. 3. Check for discoloration. Standard: Tan color. 4. Check spark plug gap. 0.7~0.8mm 0.7~0.8mm

AIR FILTER 1. Air filter 2. Wash in solvent 3. Motor oil (SEA #20) 4. Squeege out Never run engine without element.

Page 8 of the Load Up 76010 - QFD 950 user manual
Page 8 · click to enlarge
Page 8

FUEL FILTER 1. Stop the engine 2. Turn fuel cock lever to “OFF” 3. Clean with solvent

1. Clean in solvent 2. Wipe off 3. Insert
Page 9 of the Load Up 76010 - QFD 950 user manual — 8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz
Page 9 · click to enlarge
Page 9

8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz

Load Up 76010 - QFD 950 — 8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz diagram (page 9)
Fig. 1 · 8. APPLICATION RANGE AC application Model 950 Powerf…

AC output Unit Model 950 Rated voltage V 120 220 240 Frequency Hz 60 50 60 50 AC current A 6.7 3.0 3.6 2.7 Rated output VA 800 650 800 650 Model 950 Engine Operation hours 50 Hz 60 Hz

Load Up 76010 - QFD 950 — 8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz diagram (page 9)
Fig. 2 · 8. APPLICATION RANGE AC application Model 950 Powerf…
Load Up 76010 - QFD 950 — 8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz diagram (page 9)
Fig. 3 · 8. APPLICATION RANGE AC application Model 950 Powerf…
Page 10 of the Load Up 76010 - QFD 950 user manual — 8. APPLICATION RANGE AC application Model 950 Powerfactor 50 Hz
Page 10 · click to enlarge
Page 10

9. TROUBLESHOOTING Engine will not start: 1. Check fuel. Fuel cock to “ON” 2. Engine switch to “ON” 3. Controleer de bougie 4. If engine still won’t start, check following: - Fuel cock clogging - Air filter clogging Or consult your dealer 10. TECHNICAL SPECIFICATIONS Generator: Type : self-energizing, 2 poles, 1 phase Frequency : 50 Hz Voltage : 230 volt AC = alternate current AC output : continu 680 W, max. 750 W Engine: Type : 2-stroke, air cooled Fuel : mixed gas & oil 50:1 Fuel tank : 4 litres Package: Dimensions : (lxbxh) 300 x 350 x 300 mm Weight (empty) : 22,5 kg Order number : 76010

Ask about the Load Up 76010 - QFD 950

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 76010 - QFD 950

Be the first to ask — other owners or our team will answer.

Original document

Load Up 76010 - QFD 950 manual PDF

48 pages·1.5 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…