GENERATOR

Load Up 75057 — GENERATOR diagram (page 1)
Fig. 1

Manual

Page 2 of the Load Up 75057 user manual — GENERATOR
Page 2 · click to enlarge
Page 2

Version 02.2010 ENGLISH 1 Please read this manual carefully for commissioning. (NL) Waste produced by electrical machinery should not be treated as normal household waste. Ensure recycling where appropriate installations exist. Consult local authorities or the seller for advice on collection and processing.

Load Up 75057 — GENERATOR diagram (page 2)
Fig. 2
ImporterLoad Up, P. O. Box 114, NL-8900 AC Leeuwarden

www.airpress.nl

Page 3 of the Load Up 75057 user manual — GENERATOR
Page 3 · click to enlarge
Page 3

DUTCH Version 02.2010 CONTENTS 1. Safety regulations 2 2. Technical specifications 3 3. For commissioning 4 4. Start of the engine 10 5. Use 10 6. Charge 11 7. Stopping the engine 14 8. Maintenance 15 9. Storage 19 10. Malfunctions 20 ATTENTION Before you go with your LOAD-UP generator starts working, should first carefully this manual The Commission has also proposed that the Council should review this report so as to avoid accidents. PREFACE Before you go with your LOAD-UP generator starts working, should first carefully this manual The Commission has also proposed that the Council should review this report so as to avoid accidents. With the purchase of this generator you have become owner of a high quality, reliable machine. When properly used and maintained, the device will perform heavy tasks for years tirelessly. This manual contains instructions for use and maintenance. Please read it carefully before use and make sure that others who are using the generator have done so as well, taking all necessary precautions. This generator is constructed for generating electricity. The apparatus may only be used for the purpose for which it is designed and intended; all other applications are incorrect. The manufacturer shall not be responsible for any damage to persons and business caused by carelessness or failure to comply with the specified requirements during operation of the generator or maintenance work.

Page 4 of the Load Up 75057 user manual — GENERATOR
Page 4 · click to enlarge
Page 4
1. SAFETY REQUIREMENTS Work with generators is not without danger. To minimise this danger, we have developed a number of security measures. Always follow these directions and always know what you are doing. That way you can avoid many accidents.
  • Exhaust gases are toxic. Therefore, never use the generator inside a locked room, but always ensure sufficient ventilation.
  • The silencer gets very hot during use and stays hot for a while after stopping. Let the engine cool before storing the generator.
  • Diesel is highly flammable. Fill the fuel in a well ventilated space and stop the generator before you e.g. fuel.
  • Do not smoke while refilling the fuel.
  • Wipe spilled fuel immediately.
  • Connections for standby electricity to a building's electrical system shall be built only by an approved electrician and must comply with the applicable legal provisions and electrical codes. Wrong connections can be very dangerous.
  • Before you start the generator, always check the generator properly first. This will help you prevent accidents.
  • Place the generator at least 1 meter away from walls and other machines and keep yourself at least one metre away during operation.
  • Place the generator on a flat surface. If the generator is tilted, fuel could leak out.
  • The generator earths with a ground pen and wire of at least 1.5 mm 2.
  • Before starting this manual, read carefully so that you know how to operate the generator and in case of emergency stop the generator quickly. Keep children and unauthorised persons away from the generator during operation.
  • Stay away from moving parts when the generator is running.
  • If the generator is not used properly, there is a danger of an electric shock. Don't touch the generator with wet hands.
  • Do not use the generator in the rain and snow, as it is definitely not allowed to get wet.
  • WARNING: The warnings, safety instructions and directions in this manual may not include all possible circumstances and situations. The user should understand that common sense and caution are factors which cannot be incorporated into this product but must be filled in by the user himself.
  • Only persons who are aware of the use of this generator by reading these instructions will be allowed to make use of it. Unwise use is dangerous.
Page 5 of the Load Up 75057 user manual — GENERATOR
Page 5 · click to enlarge
Page 5

2. TECHICAL DATA Generator 75056: GENERATOR Frequency (Hz) 50 Power (kW) 13.5 Voltage (AC)(V) 230/400 Current (AC),(A) 230V/16A 400V/19.5A Speed (inclusive/min) 3000 Number of phases 230V/1 400V/3 Power factor (cos φ) 0.8 Generation mode automatic generation controlled by constant voltage DC output - Operating mode 12 hours continuous Structure mode manual moving Transfer fixed Gross weight (kg) 350 Dimensions (lxwxh)(mm) 1500 x 650 x 925 ENGINE Type 4-stroke, 3 cylinder, water cooled, injection diesel engine Power continuous (kW/trs/min.) 16/3000 Power max. (kW/trs/min) 17/3600 Bore x stroke (mm) 76 x 73 Cylinder capacity 993 cc Cooling water cooling Bledding oil pump Carter capacity (l) 5.2 Starter system electric Fuel diesel fuel tank capacity (L) 38 Warning system for too little oil Generator 75057: GENERATOR Frequency (Hz) 50 Power (kW) 16.25 Voltage (AC)(V) 230/400 Current (AC),(A) 230V/16A 400V/23.5A Speed (inclusive/min) 3000 Number of phases 230V . . 1f , 400V .2f Power factor (cos .) 0.8

Page 6 of the Load Up 75057 user manual — GENERATOR
Page 6 · click to enlarge
Page 6
  • Generator mode automatic generation controlled by constant voltage Operating mode 12 hours continuous Structure mode manual moving Transfer fixed Gross weight (kg) 370 Dimensions (lxwxh)(mm) 1150 x 690 x 865 MOTOR Type 4-stroke, 3 cylinder, water cooled, injection diesel engine Power continuously (kW/trs/min.) 19/3000 Power max. (kW/trs/min.) 20/3000 Bore x stroke (mm) 76 x 77 Cylinder capacity 1048 cc Cooling water-cooled Bleach oil pump Carter capacity (l) 5.2 Starter system electric Fuel diesel fuel tank capacity (L) 38 Warning system for too little oil 3. FOR USE OF THE END OF THE USE 3.1
  • Choice of fuel: Use only light diesel, which is most suitable.
  • Make sure that no dust or water enters the fuel. When you pulverize the fuel tank from a barrel, make sure that no dust or water enters the diesel. This can cause serious problems for the fuel injection pump and the atomizer.
  • Don't fill up on diesel. This is very dangerous. Fill with diesel up to the red dot in the fuel filter.
  • Note:
  • Fill the fuel in a well ventilated space and stop the generator before you e.g. fuel.
  • Do not smoke while refilling the fuel.
  • Do not fill too much fuel and tighten the cap after refilling.
  • Do not try to spill the diesel and wipe off spilled fuel immediately before starting the generator.
Page 7 of the Load Up 75057 user manual — GENERATOR
Page 7 · click to enlarge
Page 7
  • 3.2 Check and refill the engine oil Please note:
  • Always check the oil level before starting operation and fill if necessary (place the generator on a flat surface).
  • If the machine is running with too little oil, it can damage the engine seriously. It is also dangerous to fill too much oil; this can suddenly turn the engine harder.
Load Up 75057 — GENERATOR diagram (page 7)
Fig. 3

Open the side panel. Remove the probe and wipe it. Put the probe back in as indicated on the drawing. Check the oil level. If it is too low, refill with the recommended oil to the upper level (upper limit). Note: The generator is equipped with an oil warning system, which ensures that the engine stops automatically when the oil level drops below the lowest level. This prevents accidents and damage.

Page 8 of the Load Up 75057 user manual — GENERATOR
Page 8 · click to enlarge
Page 8
  • Recommended oil: SAE 15W-40 (multigrade). 3.3 Maintenance of air filter 1. Unlock the clips, remove the lid from the air filter and remove the element. Note:
  • Wasn't the element with a detergent.
  • Replace the element if necessary.
  • Never let the generator run without an element, this can cause a rapid wear and tear of the engine. 2. Replace the air filter cover and fasten the lid with the clips. Note: Never let the engine run without an air filter element or with a faulty air filter component 3.4 Checking of the generator 1. Set the main switch to . . STOP . and unplug electrical devices. Note:
  • Check that the main switch is on .
  • The generator must be grounded to prevent electrical shocks.
Load Up 75057 — GENERATOR diagram (page 8)
Fig. 4
Page 9 of the Load Up 75057 user manual — GENERATOR
Page 9 · click to enlarge
Page 9
Load Up 75057 — GENERATOR diagram (page 9)
Fig. 5
1. Open the maintenance panel. 2. Check the coolant when the machine has a normal temperature. If the level is near the MIN, refill coolant to MAX. 3. If there is no coolant in the spare tank, check for leaks and repair if necessary. Make sure there's coolant in the radiator and backup tank. Do not open the radiator when the machine is still hot, coolant can splash out and cause severe burns.

. . Wait until the machine is cold, turn the radiator cap counterclockwise

until this one stops. Don't press it while you're spinning. After the remaining pressure has been removed, remove the cap by pressing down and turning counterclockwise. . . Add enough coolant to fill the radiator and turn

Hook it up. Make sure this is securely secured. If you have a cold engine, fill in the spare tank to MAX.

Load Up 75057 — GENERATOR diagram (page 9)
Fig. 6

Cooling agent

Page 10 of the Load Up 75057 user manual — GENERATOR
Page 10 · click to enlarge
Page 10
  • Recommended coolant High quality ethylene glycol antifreeze, mixed with distilled water: 50/50. A higher concentration of antifreeze reduces cooling efficiency and is recommended only if additional protection against freezing is required. A lower antifreeze concentration will not provide sufficient protection against corrosion. When using unsuitable antifreeze, hard water or saltwater corrosion damage can occur which will reduce the life of the machine. Fuel/water separator Open the maintenance panel and check the fuel/water separater for dirt, water or sediment. Clean if necessary. Battery The battery fluid must be between the upper and lower dashes. If the level is close to the bottom indent, remove the battery cap and add distilled water to the top of the line. Do this in a well ventilated room and do NOT smoke. Warning: Chemical risk: Battery fluid contains sulphuric acid. Contact with the eyes or skin can cause severe burns. Wear a mask and protective clothing. Contrast: If battery fluid enters your eyes or skin, rinse for at least 15 minutes with warm water and call a doctor immediately. If you have been given sulphuric acid, drink large amounts of water or milk and call a doctor immediately. KEEP AWAY FROM CHILDREN! Note:
  • The main switch shall always be on .ON .O when the engine is running.
  • Before you start the engine always turn off electrical devices first.
Load Up 75057 — GENERATOR diagram (page 10)
Fig. 7
Load Up 75057 — GENERATOR diagram (page 10)
Fig. 8
Page 11 of the Load Up 75057 user manual — GENERATOR
Page 11 · click to enlarge
Page 11

3.5 Opening the panels Make sure that the generator is on a flat surface and the wheels are blocked. To open: 1. Unlock the clip and lift up the panel. 2. Pull the stopper out of the holder and attach it to the hook in order to hold up the panel. To close:

1. Lift the panel slightly to pull the stopper out of the hook. 2. Place the stopper in the holder on the maintenance panel and close it carefully. 3. Close the panel and fix it with the clip.
  • Warning: Keep the maintenance panel closed when the generator is running, otherwise cooling efficiency will be lost leading to damage to the generator. 3.6 Engine running time During the first 20 hours of operation of the engine, the user shall observe:
  • Let the engine run for 5 minutes at low speed and without load.
  • Charge the generator for only 50% during the first 20 hours of operation and leave the engine 3000 min. Turn.
  • After 20 hours of operation, change the engine oil while still warm and drain all old oil. Oil change: first time after about one month or 50 hours of operation. After that: every 3 months or 200 hours of operation. Drain finished oil according to legal requirements.
Load Up 75057 — GENERATOR diagram (page 11)
Fig. 9
Page 12 of the Load Up 75057 user manual — GENERATOR
Page 12 · click to enlarge
Page 12

3.7 Engine cooling The 75056 & 75057 are water-cooled, capacity 5 litres. Warning: Never unscrew the radiator button when the engine is still warm! Check only on cold engine. After checking, securely tighten the cap. Treate the subtank (content 0.3 litres) as above. 4. START OF THE MOTOR (see also digital panel 6.3) Before starting the engine, do not connect any electrical devices - Turn the start button to the . Then the start button to

  • Turn .START . When the engine is running, turn the start button to . Note:
  • If the starter motor continues to run for a long time, this will cost battery power and may even result in a burnt engine.
  • Always leave the start button on . . ON . when the engine is running. Battery Check the level of battery fluid every month. Fill up with distilled water to the maximum level if necessary. Note: If the level of battery fluid is too low, the engine cannot start because there is not enough power. On the other hand, if battery fluid levels are too high, it can affect surrounding parts. Make sure that the level remains between maximum and minimum. 5. USE 1. Let the engine run warm for about 3 minutes without any load. 2. Check that the oil warning light is not on. Note:
  • The oil warning light will start if the oil level is too low and stop the engine. Check the oil level and refill if necessary.
  • The speed limitation device of the engine and the fuel injection limiter must not be adjusted. Check while running the engine: 1. whether there are any abnormal sounds or vibrations. 2. whether the engine is running irregularly. 3. the colour of the exhaust gas (is the exhaust black or too white ?) If you notice any of the above, stop the engine and

detect and remedy cause or consult the technical service.

Page 13 of the Load Up 75057 user manual — GENERATOR
Page 13 · click to enlarge
Page 13
  • Note:
  • When the engine has turned, the exhaust is very hot. Do not touch the exhaust, but let it cool first.
  • Never refill fuel while the engine is running. 6. LET US GO TO THE LOCKING .
  • Do not start 2 machines at once, but start the machines one by one.
  • Do not use spotlights with other machines. 6.1 AC applications 1. Check that the engine is running at nominal speed, otherwise the AVR (Automatic Voltage Controller) will be forced. If the machine is running at too high speed for a long time, the AVR will burn through. 2. Connect the devices in a particular order. First connect the device with its most powerful power and then the lighter-powered unit. If the charging fails, the generator will suddenly stop. In this case, disconnect all electrical devices, set the main switch to .O.F. WARNING: If AC security fails, reduce load to standard power and wait a few minutes before you resume charging. 6.2 Electrical appliances and especially engines require a lot of power during start-up. Please refer to the table below for connection of devices to the generator. Type Type Wattage Wattages Incandescent lamp Glailamp Starting Startup Heating application Heater Rated Normal Fluorescent lamp fluorescent lamp TL-lamp Typical applicance Type of device Engine driven Example equipment appliances Appliance Device Electric fan Electrical fan
Page 14 of the Load Up 75057 user manual — GENERATOR
Page 14 · click to enlarge
Page 14
Load Up 75057 — GENERATOR diagram (page 14)
Fig. 10
Page 15 of the Load Up 75057 user manual — GENERATOR
Page 15 · click to enlarge
Page 15

6.3 DIGITAL PANEL 1. Turn the start key to the right to start the unit if there is no error message. The pre-glow time varies and depends on the ambient temperature (at low temperatures about 6 seconds). After successful pre-incineration, the starter will automatically hit. 2. If the unit indicates a warning, turn the stop/start key to the left to delete the error message before starting the unit. 3. Stop function: If the unit is running or starting, you can turn the stop/start key to the left to stop the unit. 4. Error messages and wizard function: If there is a malfunction in the unit somewhere, the corresponding warning light will start to lit. - Turn the key to contact you to read information from the electrical parameter if the unit stops due to the malfunction. - Turn the key to contact to clear error message and set the unit in pre-start phase. 5.Reply warning and protection function - engine oil pressure is insufficient: When the unit discovers that the motor oil pressure does not allow it to run for 1 second, the unit will stop and the relay will be activated. The light low oil pressure will start to burn. - overheating warning: When the unit receives a signal of overheating lasting longer than 1 second, the unit will stop and the relays will be activated. The light overheat will start to burn. - When the unit detects a malfunction signal of the alternator lasting longer than 3 seconds, the unit will stop and the relay will be activated. The corresponding light will start to light: alternator malfunction. - Voltage (over and under) protection warning

  • If the frequency is 50 Hz but it is above 55 Hz, then the light will flash .over/low protection .
  • If the output frequency is below 47 Hz, the light .over/low protection . will flash, then 7 seconds on and the unit will stop. - Thermal protection
  • If the current of any phase reaches 100-110% of the set current, the light .overheat . will flash. If it flickers for more than 10 seconds, the thermal protection will be switched off and the light lit. Even if more than 100% is achieved, this will happen. 6. Start fault warning If the unit does not start within 10 seconds, the relay will automatically stop the starting engine. The light . . will start the default . 7. Emergency stop indication:
Page 16 of the Load Up 75057 user manual — GENERATOR
Page 16 · click to enlarge
Page 16

If the unit gets a signal from emergency stop (emergency stop), the light will be 0.3 sec. Start burning later. 7. STOP In an emergency: Set the operating switch to .

Load Up 75057 — GENERATOR diagram (page 16)
Fig. 11
Load Up 75057 — GENERATOR diagram (page 16)
Fig. 12
Page 17 of the Load Up 75057 user manual — GENERATOR
Page 17 · click to enlarge
Page 17

In a normal situation:

Load Up 75057 — GENERATOR diagram (page 17)
Fig. 13
1. Turn the on/off switch off 2) turn off thermal protection
Load Up 75057 — GENERATOR diagram (page 17)
Fig. 14
  • 3) Turn the start switch to . WARNING
  • Never stop the engine with the decompression lever.
  • Never stop the generator when all devices are still connected, but unplug these devices first. 8. MAINTENANCE Regular monitoring and maintenance is very important if you want to keep your machine in good condition. Remember that regular maintenance will benefit your machine's efficiency and maintain your machine ! Please refer to the schedule below for work to be done. WARNING
  • Before starting maintenance work on the machine, power must be switched off (please note that it cannot be switched on by accident). If the machine has to run, make sure that space is properly ventilated because the generator exhaust gas contains toxic carbon monoxide gas.
  • After use clean the generator with a cloth to prevent rust formation and remove attack.
Page 18 of the Load Up 75057 user manual — MAINTENANCE TABLE
Page 18 · click to enlarge
Page 18

MAINTENANCE TABLE

Diagram . .
Diagram . .

Check and refill fuel every year or 1000 hours.

If the generator is out of service for more than 10 days

Page 19 of the Load Up 75057 user manual — MAINTENANCE TABLE
Page 19 · click to enlarge
Page 19

8.1 Refreshing engine oil (see also 3.2) Open the maintenance panel. Remove the oil gauge stick and open the drain plug to remove the engine oil. Replace the drain plug. Add engine oil and check the level of oil. Screw the oil-level stick cap back on. Used motor oil can cause skin cancer if it comes into long-term contact with the skin. It is advisable to wash your hands thoroughly with soap and water as soon as possible after removing the engine oil. The used engine oil should be collected and transported as required. Don't throw this in the garbage or into the sewer. 8.2 Refresh oil filter Cleaning: every 6 months or every 400 hours. Replace if necessary. Oil filter Oil filter Drain plug Plug 8.3 Replacing the air filter element: see 3.3 Note: Never let the engine run without an air filter element or with a defective air filter component. 8.4 Cleaning and replacing the fuel filter Fuel is flammable and explosive under certain conditions: do not smoke or expose open fire/fire to the machine. The fuel filter should be cleaned regularly to ensure maximum capacity. Cleaning: Replace every 6 months or every 500 hours: Every year or every 1000 hours

Load Up 75057 — MAINTENANCE TABLE diagram (page 19)
Fig. 16
1. Open the side panel 2. Tap the fuel 3. Remove the ring and remove the glass with spring and element. 4. Clean the glass properly.
Page 20 of the Load Up 75057 user manual — MAINTENANCE TABLE
Page 20 · click to enlarge
Page 20

5. Mount a new element and re-assemble the spring with glass and ring. Note: Make sure that the o-ring is reassembled in good condition. 8.5 Fitting of cylinder head screws The screwing of the cylinder head requires special tools. Contact your dealer. 8.6 Checking the atomizer and fuel injection pump 1. Setting of openings for inlet and outlet valves. 2. Cutting of the inlet and outlet valves. 3. Replace the piston spring. The above work must be carried out by a professional. Contact your dealer. Note: • Never check the atomizer near open fire, the fuel nebula may ignite. Make sure the fuel mist cannot get to your skin; it can penetrate the skin and cause injury. Always keep the atomizer away from your body. 8.7 Checking the electrolyte and charging of the battery The diesel generator has a 12 V battery. When charging and unloading the battery a little electrolyte is lost. Before starting, check the battery for visible damage, check electrolyte level and refill with distilled water to maximum levels if necessary. Check the electrolyte every month.

Load Up 75057 — MAINTENANCE TABLE diagram (page 20)
Fig. 17
Load Up 75057 — MAINTENANCE TABLE diagram (page 20)
Fig. 18
Page 21 of the Load Up 75057 user manual — MAINTENANCE TABLE
Page 21 · click to enlarge
Page 21
Load Up 75057 — MAINTENANCE TABLE diagram (page 21)
Fig. 19
  • Warning:
  • The electrolyte contains sulfuric acid. Protect your eyes, skin and clothing. If you do come into contact with the sulphuric acid, rinse plenty of water and consult a doctor immediately, especially if it concerns your eyes.
  • The battery produces hydrogen gas, which is highly explosive. Do not smoke near the battery and do not place the battery near flames or sparks, especially during charging. 8.8 Check the cabbage brush and the tow ring regularly. Adjust if there are sparks. 9. STORAGE FOR LONG TIME If the generator is stored for a long time, observe the following points: 1. Cleaning machine 2. Pre-service a maintenance according to the maintenance table. 3. Refresh oil for commissioning. 4. Fill fuel tank with clean diesel oil. 5. Unlock and isolate the battery clamps. Check the battery every month. 6. Cover the generator and place it in a well ventilated, dry space. When the generator is still warm, wait until it cools down. Before commissioning: Remove the radiator cap and check the cooling system. When the coolant level is too low, consult the service department.
Page 22 of the Load Up 75057 user manual — MAINTENANCE TABLE
Page 22 · click to enlarge
Page 22

10. MALFUNCTIONS The engine won't start: Cause Solution Too little fuel Refill Fuel injection pump and sprayer Remove the fuel injection pump leaving no or not enough fuel through. and the sprayer, clean them. The start button is not on the Start button at position START. Position START. Check the oil level. The oil level shall be between the min and max. level. The atomizer is dirty. Clean up. The battery does not give enough Charge or replace with a power. New. If electricity is not generated: Cause Solution The main switch is not on . Turn the switch to . The carbon brushes are worn out. Replace. The wall socket is defective. Check and repair. The nominal speed cannot be set according to the instructions. achieved. The AVR is damaged. Replace.

Page 23 of the Load Up 75057 user manual — 75056 / 75057
Page 23 · click to enlarge
Page 23

75056 / 75057

Load Up 75057 — 75056 / 75057 diagram (page 23)
Fig. 20
Page 24 of the Load Up 75057 user manual — 75056 / 75057
Page 24 · click to enlarge
Page 24
Page 24 of the Load Up 75057 user manual — 75056 / 75057
Page 25 of the Load Up 75057 user manual — 75056 / 75057
Page 25 · click to enlarge
Page 25

- - - - - - - -

Load Up 75057 — 75056 / 75057 diagram (page 25)
Fig. 21
Page 26 of the Load Up 75057 user manual — 75056 / 75057
Page 26 · click to enlarge
Page 26

GUARANTEE PROVISIONS The warranty of the machine/machine delivered is 12 months starting on the purchase date. If there are any faults within this time due to material or construction defects, the guarantee applies for both parts and labour costs. Guarantee claims shall not be recognised if: - The instructions in this manual have not been complied with. - The machine/machine has been modified to prevent it from functioning properly, even when the correct components were used for replacement. - Damage caused by freezing, falling, bumping, unauthorized dismantling, faulty connection to the electricity grid etc. - Damage is caused by the use of extension cords thinner than 2.5 mm2 (only applicable to 230 V). If the warranty claim is recognised, the machine/machine will be returned free of charge after repair. Further compensation shall not be granted. GUARANTEED BEST IMMUNOGEN Die Waardenfrist der geloverten Maschine/des Apparats beträgt 12 Monate, mit Wirkung vom Kauf- date. Wenn es innerhalb dieser Frist Störungen gibt, die auf Material- oder Konstructuresfehler zurückzuführen sind, guild die Garantie für sowohl Teile wie auch Arbeitslohn. Warranty fee were not anerkannt, wenn: - Those Hinweise in dieser Gebrauchsanweisung nicht eingeringen are sind. - Die Maschine / der Apparat derart geändert ist, dass dieser nicht mehr bührendermassen funktionieren kanne, auch nichts, wenn die gerichtiggen Teile zum Auswechseln eingesetzt wurden. - Schäden durch Erfrieren, Fallen, Stösse, unbefugtes Demontieren, fehlerhaften Anschluss an das Stromnetz usw. Entstehen. - Schaden durch Benutzung von Verlängerungskabeln dünner as 2.5 mm2 entstehen. Gilt nur bei 230 Volt. Wenn der Garantieanspruch anerkannt wird, wird die Maschine/der Apparat nach der Reparatur franko zurückgesandt. Ein weiterer Schadenersatz wird nicht gewährt. GUARANTEE PROVISIONS The machine/apparatus supply carries a twelve month guarantee, starting drum the day of purchase. If any breakdowns occur within this period, caused by material or structural defects, this guarantee will cover parts as well as labour costs. This guarantee will not cover claims if: - The instructions in this manual have not been observed. - The machine / apparatus has been modified in such a way that it no longer functions properly, not even when damaged parts are replaced with the clean components. - Damage is due to frost, dropping, impact, unauthorized disassemblely, impoper connection to the electricity grid etc. - Damage is due to the use of extension leads thinker than 2,5 mm2. This only applies to 230 volts. If the guarantee claim is accepted, the machine/appartatus will be repaired and returned free of charge. No other damages will be paid. CONDITIONS THE WARRANTY Le délai de garantie de la machine/de I'appareil est de 12 mois, à compter de la date d'acquisition. Au cas ou des difficultés techniques dues à des défauts de öperiau or de construction se présen- teraient pendant ce délai, la garantie concernera tant les pièces détachées qua la main-d'oeuvre. On ne pourra prétendre à aucune garantie dans les cas suivants: - Les instructions prévues par la noticee n'ont pas été respectées. - La modification de la machine/de I'appareil empêche son fonctionnement, même si les pièces appréées ont été utilizées. - Dégáts öfériels sous au fait que la machine/l'appareil est tombé(e), a gelé(e) heurté(e). quelque chose ou qu'elle (qu'il) a été mal démonté(c), branché(es) incorrectement sur le réseau etc. - Dégáts öfriels à I'emploi de rallonges faisant moins de 2,5 qmm. Seulement and cas de 230V. Au cas ou la réclamation serait retenue, la machine/l'appareil sera renvoyé(e) franc de port à I'issue des travaux de réparation. Il ne sera accordé aucun dédommagement ultérieur.

- - - - - - - -

Page 27 of the Load Up 75057 user manual — 75056 / 75057
Page 27 · click to enlarge
Page 27

EC declaration of conformity We, Load Up, mailbox 114, 8900 AC Leeuwarden, Netherlands, declare entirely under their own responsibility that the products Generators 75056-75057 to which this declaration relates, comply with the following standards: EN 60335-1 en EN 60335-2-29 and the Directives: the EMC Directive 89/336/EC, the CE marking Directive 93/68/EC, Directive 72/23/EC and Directive 2000/14/EC Netherlands, Leeuwarden, 22 February 2010 EEG-Konformitätserklärung Wir, Load Up, Postfach 114, 8900 AC, L eeuwarden, Niederlande, erklären ganz auf eigene Verantwortung, dass die Produkte Generatore 75056-75057 auf das sich diese Erklärung bezieht mit den Noormen EN 60335-1 und EN 60335-2-29 übereinstimmen und den Richtlinien: EMC Directive 89/336/EC, CE marking 93/68/EC, of the Directive 72/23/EC and of the directive 2000/14/EC Niederlande, Leeuwarden, den 22. February 2010 EC declaration of conformity We, Load Up, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the products Generators 75056-75057 to which this declaration references, comply with the standards EN 60335-1 and EN 60335-2-29 and the directives: EMC directive 89/336/EC, CE marking directive 93/68/EC, the directive 72/23/EC and the directive 2000/14/EC The Netherlands, Leeuwarden, 22nd February 2010 Déclaration CE de conformité Now, Load Up, P.O. Box 114, 8900 AC Leeuwarden, Pays Bas, déclarons entièrement sous notre propre responsabilité que les produits Générateurs 75056-75057 auquel cette déclaration a trait sont conformes aux normes EN 60335-1 et EN 60335-2-29 et aux directives: la directive EMC 89/336/EC, la directive CE marking 93/68/EC, La directive 72/23/EC et la directive 2000/14/EC Pays Bas, Leeuwarden, le 22 février 2010 Declaration of conformity Load Up, C.P. 114, 8900 AC Leeuwarden, Paises Bajos, declaramos bajo nuestra exclusiva responsabilidad la conformidad del producto Generatador 75056-75057 al que se refiere esta declaración, con las disposiciones de la Directiva Directivas 89/336 CE, 93/68 CE, 72/23 CE y 2000/14/CE Para local se han seguido las normas EN 60335-1 y EN 60335-2-29 Paises Bajos, Leeuwarden, el 22 de febrero 2010 E.J. de Vries Directeur/Geschäftsführer/Managing Director/Director général/Directory gerente

Load Up 75057 — 75056 / 75057 diagram (page 27)
Fig. 22
Page 28 of the Load Up 75057 user manual — GENERATOR
Page 28 · click to enlarge
Page 28

Manual

Version 02.2010

GENERATOR

75056 75057

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Load Up 75057

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75057

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75057 manual PDF

28 pages·911 KB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…