ENGLISH CONTENTS 1. Safety instructions 29 2. Technical specifications 30 3. Preparation for starting 31 4. Start the generating set 33 5. Operate the generating Set 33 6. Load 34 7. Stop the generating set 36 8. Periodic checks and service 36 9. Long-term storage 39 10. Troubleshooting and remedy 40 ATTENTION Before using your LOAD-UP generator, first read this manual thoroughly, so that accidents can be prevented. GENERAL Having bought the LOAD-UP generator, you have become the owner of a high quality, reliable machine. Using it properly and maintaining it regularly, the generator will carry out heavy jobs for years to come. In this operation manual you will find use and maintenance prescriptions. Before using the generator, read this manual first and be sure that others have read it as well and have taken the necessary precautions. This generator has been designed and intended for generating electricity. The appliance must be used only for the purpose for which it was specifically designed. All other uses are to be considered incorrect and therefore unreasonable. The manufacturer cannot be held responsible for any damage resulting from improper, incorrect or unreasonable use. 1. SAFETY INSTRUCTIONS Working with generators is not without danger. To reduce this danger as much as possible, we have drawn up a number of safety measures. Always follow up these directives and always be aware of what you are doing. In this way many accidents can be avoided.


system will be heated during operation and remain hot immediately after stopping the engine.

Generator 75051: GENERATOR DATA Rated frequency (Hz) 50 Rated power (kW) 5,5 Rated voltage (AC) (V) 400/230 Rated current (AC) (A) 7,9 Rated revolution speed (rpm) 3000 Phases single Power factor (cosø) 0,8 Excitation mode controlled silicon self excitation constant voltage Operation mode 12 hours continuous running Structure mode Hand cart type Coupling method Transmission rigid connection Gross weight (kg) 171 Overall dimensions (LxWxH mm) 910 x 520 x 740 MOTOR DATA Type 4-stroke, single cylinder, direct injection diesel engine Continual output (kW/rpm) 5,7/3000 Max. power (kW/rpm) 6,3/3300 Bore x stroke (mm) 86 x 72 Displacement (l) 0,418 Cooling system Forced air cooling Lubrication system Pressure splashing Lube oil capacity (l) 1.65 Starting system Electric starter Fuel oil Diesel oil Fuel tank volume (l) 16 Low oil alarm system Will switch off the engine



BATTERY Check the battery electrolyte level every month. Refill the distelled water until the upper limits if the electrolyte dropped to the lower limits. Caution: If the electrolyte level is too low, the engine may fail to start because there is not sufficient power. On the other side, if the electrolyte level is too high, the fluid will corrode the surrounding parts.Do keep the electrolyte level between the upper and lower limits.
5.2 Checks during the running 1. Whether there is abnormal sound or vibration; 2. Whether the engine misfires or runs rough; 3. Check the color of the exhaust. (Is it black or too white?) If you notice any of the above-mentioned phenomenon happened, stop the engine and find out the fault cause or contact with our agents.


6.3 Electric appliance particularly moto-driven equipment will produce very high current while starting, below the table provides the reference for connecting these apparatus to the generating set.




The generating set has been stored more than 10 days.

8.1 Replace engine oil Remove the oil filter cap. Remove the drain plug and drain the old oil while the engine is still warm. The plug is located on the bottom of the cylinder block. Tighten the drain plug and refill with the recommended oil. 8.2 Clean the engine oil filter Cleaning time: Every 6 months or 500 hours. Replace if necessary. 8.3 Replace the air cleaner element. Do not clean the aircleaner with detergent. Replace time: Every 6 months or 500 hours. Caution: • Never run the engine without the element or with a defective element. 8.4 Clean and replace fuel oil filter The fuel oil filter also has to be cleaned regularly to insure maximum engine output. Cleaning time: Every 6 months or 500 hours. Replace time: Every year or 1000 hours. 1.Drain out the fuel from the fuel tank. 2. Drain out the fuel from the fuel tank. Screw off the small screw of the fuel cock and pull out the filter from the filler port. 3. Wash the filter thoroughly with diesel fuel. Loosen the fastening nut, bottom cover and delivery discs for cleaning the deposit carbon.






3 Remove the screw plug on the cylinder head cover and refill 2cc engine oil, then put the plug in place. 4 Turn the engine 2-3 seconds with the decompression lever set at the non- compression position, and the starting key at the "START" position.( (Do not start the engine.) 5 Wipe off the oil and dirt from the engine and store in a dry place.