GENERATOR GENERATOR

GENERADOR

Manual Manuel d.o.b.

Page 2 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 2 · click to enlarge
Page 2

Version 02.2007 ENGLISH 1 FRANÇAIS 14 ESPAÑOL 28 Please read this manual carefully. Avant toute utilization de lövappareil, lire avec attention le présent manual dövinstructions. Antes de usar esta generador, leer attentamente las instrucciones de empleo. (NL) Waste produced by electrical machinery should not be treated as normal household waste. Ensure recycling where appropriate installations exist. Consult local authorities or the seller for advice on collection and processing. (F) Les déchets électriques ne peuvent être traités de la même manière que les ordures ménagères vundaires. Procéder à leur recycling, là où il existe des installations adéquates. S'addresser aux autorités locales compétentes ou à un revendeur agréé pour serenseigner à propos des processen de collecte et de traitement. (E) Los desechos producidos por las máquinas eléctricas no se pueden tratar como desechos domésticos comunes. Hay que reciclarlos allí donde existan las instalaciones apropiadas. Consultar al organismo local o al revendor para solicitar información acerca de su recogida y eliminación.

Load Up 75049 — GENERATOR GENERATOR diagram (page 2)
Fig. 1
Load Up 75049 — GENERATOR GENERATOR diagram (page 2)
Fig. 2
ImporterLoad Up, P. O. Box 114, NL-8900 AC Leeuwarden

www.airpress.nl

Page 3 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 3 · click to enlarge
Page 3

DUTCH Version 02.2007 CONTENTS 1. Safety regulations 2 2. Technical specifications 3 3. For commissioning 3 4. Start of the engine 5 5. Use 6. Charge 6 7. Stopping the engine 8 8. Maintenance 8 9. Storage 12 10. Malfunctions 13 ATTENTION Before you go with your LOAD-UP generator starts working, should first carefully this manual The Commission has also proposed that the Council should review this report so as to avoid accidents. PREFACE With the purchase of this generator you have become owner of a high quality, reliable machine. When properly used and maintained, the device will perform heavy tasks for years tirelessly. This manual contains instructions for use and maintenance. Please read it carefully before use and make sure that others who are using the generator have done so as well and taken all necessary precautions. This generator is constructed for electricity generation and is also suitable for charging auto-accuulatory batteries. The apparatus may only be used for the purpose for which it is designed and intended; all other applications are incorrect. The manufacturer shall not be responsible for any damage to persons and business caused by carelessness or failure to comply with the specified requirements during operation of the generator or maintenance work.

Page 4 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 4 · click to enlarge
Page 4
1. SAFETY REQUIREMENTS Work with generators is not without danger. To minimise this danger, we have developed a number of security measures. Always follow these directions and always know what you are doing. That way you can avoid many accidents.
  • Exhaust gases are toxic. Therefore, never use the generator inside a locked room, but always ensure sufficient ventilation.
  • The silencer gets very hot during use and remains hot for a while after stopping. Let the engine cool before storing the generator.
  • Diesel is highly flammable. Fill the fuel in a well ventilated space and stop the generator before you e.g. fuel.
  • Do not smoke while refilling the fuel.
  • Wipe spilled fuel immediately.
  • Connections for standby electricity to a building's electrical system shall be built only by an approved electrician and must comply with the applicable legal provisions and electrical codes. Wrong connections can be very dangerous.
  • Before you start the generator, always check the generator properly first. This will help you prevent accidents.
  • Place the generator at least 1 meter away from walls and other machines and keep yourself at least one metre away during operation.
  • Place the generator on a flat surface. If the generator is tilted, fuel could leak out.
  • The generator earths with a ground pen and wire of at least 1.5 mm 2.
  • Before starting this manual, read carefully so that you know how to operate the generator and in case of emergency stop the generator quickly. Keep children and unauthorised persons away from the generator during operation.
  • Stay away from moving parts when the generator is running.
  • If the generator is not used properly, there is a danger of an electric shock.
  • Don't touch the generator with wet hands.
  • Do not use the generator in the rain and snow, as it is definitely not allowed to get wet.
  • WARNING: The warnings, safety instructions and directions in this manual may not include all possible circumstances and situations. The user should understand that common sense and caution are factors which cannot be incorporated into this product but must be filled in by the user himself.
  • Only persons who are aware of the use of this generator by reading these instructions will be allowed to make use of it. Unwise use is dangerous.
Page 5 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 5 · click to enlarge
Page 5
  • 2. TECHICAL DATA GENERATOR Frequency 50 Hz Power 5 kW Voltage (AC) 230 V Current (AC), 21.7 A Speed 3000 rpm. Number of phases 1 Power factor (cos φ) 1 Generation mode automatic generation controlled by constant voltage DC output 12V/8.3A Operating mode 12 hours continuous Structure mode manual moving Transfer fixed Gross weight 171 kg Dimensions (lxwxh) 930 x 515 x 755 mm MOTOR Type 4-stroke, 1 cylinder, air cooled, injection diesel engine power continuously 5.7 kW/3000 rpm. Power max. 6.3 kW/8.6 hp/3300 rev/min. Bore x stroke 86 x 72 mm Cylinder capacity 0.418 liters/418 cc Cooling forced air cooling Smear oil pump Carter capacity 1.65 liters Starter system electric Fuel diesel Fuel tank capacity (l) 16 Warning system for too little oil Noise level at 7 meter 68 dB(A) 3. FOR USE OF THE END OF THE USE 3.1
  • Choice of fuel: Use only light diesel, which is most suitable.
  • Make sure that no dust or water enters the fuel. When you pulverize the fuel tank from a barrel, make sure that no dust or water enters the diesel. This can cause serious problems for the fuel injection pump and the atomizer.
Page 6 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 6 · click to enlarge
Page 6
  • Don't fill up on diesel. This is very dangerous. Fill with diesel up to the red dot in the fuel filter.
  • Note:
  • Fill the fuel in a well ventilated space and stop the generator before you e.g. fuel.
  • Do not smoke while refilling the fuel.
  • Do not fill too much fuel and tighten the cap after refilling.
  • Do not try to spill the diesel and wipe off spilled fuel immediately before starting the generator. 3.2 Check and refill the engine oil Please note:
  • Always check the oil level before starting operation and fill if necessary (place the generator on a flat surface).
  • If the machine is running with too little oil, it can damage the engine seriously. It is also dangerous to fill too much oil; this can suddenly turn the engine harder. Note: The generator is equipped with an oil warning system, which automatically stops the engine when the oil level drops below its lowest. This prevents accidents and damage. Recommended oil: SAE 15W-40 (multigrade). 3.3 Maintenance of air filter 1. Unscrew the wing nut, remove the lid from the air filter and remove the element. Note:
  • Wasn't the element with a detergent.
  • Replace the element if necessary.
  • Never let the generator run without an element, this can cause a rapid wear and tear of the engine. 2. Replace the air filter cover and tighten the wing nut again. 3.4 Checking the generator 1. Set the main switch to . . STOP . and unplug electrical devices. Note:
  • Check that the main switch is on .
  • The generator must be grounded to prevent electrical shocks.
Page 7 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 7 · click to enlarge
Page 7
  • Note:
  • The main switch shall always be on .ON .O when the engine is running.
  • Before you start the engine always turn off electrical devices first. 3.5 Opening of panels 1. Open the generator's daily control panel. Turn the lever against clockwise and lift up the panel. 3.6 Engine running time During the first 20 hours of operation of the engine, the user shall observe:
  • Let the engine run for 5 minutes at low speed and without load.
  • Charge the generator for only 50% during the first 20 hours of operation and leave the engine 3000 min. Turn.
  • After 20 hours of operation, change the engine oil while still warm and drain all old oil. Oil change: first time after about one month or 20 hours of operation. After that: every 3 months or 100 hours of operation. Drain finished oil according to legal requirements. 3.7 Cooling engine The generator's motor is air-cooled. 4. START OF THE MOTOR Before starting the engine, do not connect electrical devices - Turn the start button to the . Then the start button to
  • Turn .START . When the engine is running, turn the start button to . Note:
  • If the starter motor continues to run for a long time, this will cost battery power and may even result in a burnt engine.
  • Always leave the start button on . . ON . when the engine is running. Battery Check the level of battery fluid every month. Fill up with distilled water to the maximum level if necessary.
Page 8 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 8 · click to enlarge
Page 8
  • Note: If the battery fluid level is too low, the engine cannot start because there is not enough power. On the other hand, if battery fluid levels are too high, it can affect surrounding parts. Make sure that the level remains between maximum and minimum. 5. USE 1. Let the engine run warm for about 3 minutes without any load. 2. Check that the oil warning light is not on. Note:
  • The oil warning light will start if the oil level is too low and stop the engine. Check the oil level and refill if necessary.
  • The speed limitation device of the engine and the fuel injection limiter must not be adjusted. 5.2 Check while running the engine: 1. whether there are any abnormal sounds or vibrations. 2. whether the engine is running irregularly. 3. the colour of the exhaust gas (is the exhaust black or too white ?) If you notice any of the above points, stop the engine and

detect and remedy cause or consult the technical service.

  • Note:
  • When the engine has turned, the exhaust is very hot. Do not touch the exhaust, but let it cool first.
  • Never refill fuel while the engine is running. 6. LET US GO TO THE LOCKING .
  • Do not start 2 machines at once, but start the machines one by one.
  • Do not use spotlights with other machines. 6.1 AC applications 1. Check that the engine is running at nominal speed, otherwise the AVR (Automatic Voltage Controller) will be forced. If the machine is running at too high speed for a long time, the AVR will burn through. 2. When the voltage generator (AC .dc) is alternating, the operating switch shall be set to the position .off . Otherwise, the generator and electrical devices will burn through and damage. 3. Connect the devices in a particular order. First connect the device with its most powerful power and then the lighter-powered unit. If the charging fails, the generator will suddenly
Page 9 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 9 · click to enlarge
Page 9
  • Stop. In this case, disconnect all electrical devices, set the main switch to .O.F. WARNING: If AC security fails, reduce load to standard power and wait a few minutes before you resume charging. 6.2 DC applications 1. The DC connection points are only for charging 12 V batteries. 2. During charging, turn the air switch to . On the 12 V stop point is an ON/OFF switch. 3. When it comes to an automatic battery with connections, it is important to disconnect the negative connections of the battery during charging. Note:
  • Connect the positive and negative poles of the battery to the positive or negative pole of the DC connections. Connect the positive pool to the positive pole etc. and do not change the poles, otherwise the battery and generator will burn.
  • Do not connect the positive battery pool to the negative battery pool, which can cause serious damage to the battery.
  • The same applies to the poles of the 12 V connection.
  • If you try to charge a heavy battery, the fuse of 12 V connection can jump out.
  • Do not let the generator run if the battery is still connected.
  • Do not use the DC and AC connections simultaneously. Note:
  • During charging, the battery produces flammable gas. Keep sparks, flames and cigarettes away from the battery. To prevent sparks near the battery, always first attach the charging cables to the battery and then attach the charge cables to it. First disconnect the charge cables of the generator and then off the battery.
  • Charge the battery in a well ventilated space.
  • To charge remove the caps of cells from the battery.
  • Stop charging if the electrolyte temperature exceeds 45 °C. 6.3 Electrical appliances and especially engines require a lot of power during start-up.
Page 10 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 10 · click to enlarge
Page 10
  • See the table on page 41 to connect devices to the generator. Type Type Rated Normal Wattage Wattages Incandescent lamp Glailamp Starting Startup Heating application Heater Rated Normal Fluorescent lamp fluorescent lamp TL-lamp Typical application Type of device Engine driven Example equipment appliances Appliance Device Electric fan Electrical fan Launch 7. STOP 1. Disconnect all connected devices. 2. Set the operating switch to . WARNING
  • Never stop the engine with the decompression lever.
  • Never stop the generator when all apps are connected, but unplug these devices first. 8. MAINTENANCE Regular monitoring and maintenance is very important if you want to keep your machine in good condition. Remember that regular maintenance will benefit your machine's efficiency and maintain your machine ! Please refer to the schedule below for work to be done. WARNING
  • Before starting maintenance work on the machine, power must be switched off (please note that it cannot be switched on by accident). If the machine has to run, make sure that space is properly ventilated because the generator exhaust gas contains toxic carbon monoxide gas.
  • After use clean the generator with a cloth to prevent rust formation and remove attack.
Page 11 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 11 · click to enlarge
Page 11
Every dayAfter 1 month or 20 hoursAfter 3 months or 100 hoursAfter 6 months or 500 hoursEvery year or 1000 hours Check and refill fuel.• Check and refill engine oil.• Check for oil leakage.• Tighten the screws.•• Refreshing engine oil.•• Refresh oil filter.• Replace air filter element.In dusty environment more often replaced.• Cleaning fuel filter.•Replace Check fuel injection pump• Checking for spray.• Checking fuel line.• Adjust the flow of inlet and outlet valves.•• Cut inlet exhaust valves.• Replaced the suction feather.• Checking the battery.• Checking for a carbon brush and slip ring.• Checking isolation resistance.If the generator has been out of service for more than 10 days.
Diagram . .
Diagram . .
Page 12 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 12 · click to enlarge
Page 12

8.1 Refreshing engine oil Remove the oil filler cap and drain plug and tap the oil while the engine is still warm. Catch and dispose of waste oils according to the regulations. The plug is located at the bottom of the cylinder block. Replace the drain plug and fill with new recommended oil. Oil filter cap/dipstick Oil filler cap/tub Drain plug Tap plug 8.2 Cleaning oil filter Cleaning: every 6 months or every 500 hours. Replace if necessary. Oil filter Oil filter Drain plug Plug 8.3 Replacing the air filter element Do not clean the air filter element with a detergent. Replace: every 6 months or every 500 hours. Note: Never let the engine run without an air filter element or a defective air filter component 8.4 Cleaning and replacing the fuel filter The fuel filter should be cleaned regularly to ensure maximum capacity. Cleaning: Replace every 6 months or every 500 hours: Every year or every 1000 hours

Page 13 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 13 · click to enlarge
Page 13

1. Tap all fuel from the tank. 2. Unscrew the 3 small screws and remove the fuel filter. 3. Wash the filter thoroughly with diesel. Unscrew the nut and lower cover and remove the carbon impact. Drain Plug-in Folder. 8.5 Fitting of cylinder head screws The screwing of the cylinder head requires special tools. Contact your dealer. 8.6 Checking the atomizer and fuel injection pump 1. Setting of openings for inlet and outlet valves. 2. Cutting of the inlet and outlet valves. 3. Replace the piston spring. The above work must be carried out by a professional. Contact your dealer. Note: • Never check the atomizer near open fire, the fuel nebula may ignite. Make sure the fuel mist cannot get to your skin; it can penetrate the skin and cause injury. Always keep the atomizer away from your body. 8.7 Checking the electrolyte and charging of battery The diesel generator has a 12 V battery. When charging and unloading the battery a little electrolyte is lost. Before starting, check the battery for visible damage, check electrolyte level and refill with distilled water to maximum levels if necessary. Check the electrolyte every month.

Page 14 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 14 · click to enlarge
Page 14
  • Warning:
  • The electrolyte contains sulfuric acid. Protect your eyes, skin and clothing. If you do come into contact with the sulphuric acid, rinse plenty of water and consult a doctor immediately, especially if it concerns your eyes.
  • The battery produces hydrogen gas, which is very explosive. Do not smoke near the battery and do not place the battery near flames or sparks, especially during charging. 8.8 Check the cabbage brush and the tow ring regularly. Adjust if there are sparks. 9. STORAGE FOR LONG TIME If the generator is stored for a long time, observe the following points: 1. Let the engine run for about 3 minutes without any load and then stop it. 2. Tap the engine oil while the engine is still warm and refill with new oil. 3. Remove the screw plug on the cylinder head, fill 2cc of engine oil and place the screw crank back. 4. Turn the engine 2-3 seconds with the decompression lever in position . . no compression . and the start button at position . 5. Push up the decompression lever. Pull the starter cable until you feel resistance (in this position both the inlet and outlet valve are closed) and leave the lever in this position. This prevents the engine from rusting. 6. Wipe the oil and dirt from the engine and store the generator in a dry, well ventilated space.
Page 15 of the Load Up 75049 user manual — GENERATOR GENERATOR
Page 15 · click to enlarge
Page 15

10. MALFUNCTIONS The engine won't start: Cause Solution Too little fuel Refill Fuel injection pump and sprayer Remove the fuel injection pump leaving no or not enough fuel through. and the sprayer, clean them. The start button is not on the Start button at position START. Position START. Check the oil level. The oil level shall be between the min and max. level. The battery does not give enough Charge or replace with a power. New. If electricity is not generated: Cause Solution The main switch is not on . Turn the switch to . The carbon brushes are worn out. Replace. The wall socket is defective. Check and repair. The nominal speed cannot be set according to the instructions. achieved. The AVR is damaged. Replace.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Load Up 75049

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75049

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75049 manual PDF

48 pages·2.2 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…