  • Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location.
  • Wipe up spilled gasoline at once.
  • Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building’s electrical system.
  • Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage.
  • Place the generator at least 1 m away from buildings or other equipment during operation.
  • Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
  • Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions.
  • Keep children and pets away from the generator when it is in operation.
  • Keep away from rotating parts while the generator is running.
  • The generator is a potential source of electrical shocks when misused; do not operate with wet hands.
  • Do not operate the generator in rain or snow and do not let it get wet.
  • WARNING: the warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
  • Only those persons who are aware of how to use the generator by having read this manual, should use the machine. Injudicious use may cause danger. 3. PRE-OPERATION CHECK Fuel tank capacity: 15 litres. Use unleaded petrol and do not fill above fuel filter top. Checking the oil level: 1. remove the oil dipstick and wipe it clean. 2. check the oil level and refill if necessary. 3. replace the dipstick. Recommended oil: SAE 15W-30 (multigrade). Oil capacity in crankcase: 0,7 litre.
Load Up 75032 diagram (page 2)
Fig. 1
Load Up 75032 diagram (page 2)
Fig. 2
Page 3 of the Load Up 75032 user manual
Page 3 · click to enlarge
Page 3
4. STARTING THE ENGINE Before starting, do not connect electric apparatus. 1. Turn fuel cock lever to "ON". 2. Turn chock lever to "1". 3. Turn engine switch to "ON". 4. Pull slowly on recoil starter until engaged, then pull it briskly.
Load Up 75032 diagram (page 3)
Fig. 3
Load Up 75032 diagram (page 3)
Fig. 4
Load Up 75032 diagram (page 3)
Fig. 5
Load Up 75032 diagram (page 3)
Fig. 6
Load Up 75032 diagram (page 3)
Fig. 7
Load Up 75032 diagram (page 3)
Fig. 8
Page 4 of the Load Up 75032 user manual
Page 4 · click to enlarge
Page 4
5. Return chock lever slowly. 5. STOPPING THE ENGINE 1. Before stopping, turn off electric apparatus. 2. Turn engine switch to "STOP". 3. Turn fuel cock lever to "OFF".
Load Up 75032 diagram (page 4)
Fig. 9
Load Up 75032 diagram (page 4)
Fig. 10
Load Up 75032 diagram (page 4)
Fig. 11
Page 5 of the Load Up 75032 user manual
Page 5 · click to enlarge
Page 5
6. CONNECTION Connection AC: - Start the engine. - Plug into AC socket. SAFETY DEVICES Turn switch to “ON” to reset AC protector. Reduce load within rated output if AC protector (if equipped) turns off. Warning: to prevent electric shocks, the generator must be earthed.
Load Up 75032 diagram (page 5)
Fig. 12
Load Up 75032 diagram (page 5)
Fig. 13
Load Up 75032 diagram (page 5)
Fig. 14
Page 6 of the Load Up 75032 user manual — 7. MAINTENANCE Item Remarks Daily Every 50 hours or every month
Page 6 · click to enlarge
Page 6

7. MAINTENANCE Item Remarks Daily Every 50 hours or every month

Every 150 hours or every 12 months Spark plug

Remove carbon. Adjust gap. Replace if necessary.

Clean. Replace if necessary.

Clean. Replace if necessary.

▀ Check. ▀

Refresh if necessary: first time after 50 hours.

▀ Fuel hose Check. ▀ Carburetor Check.

Check if necessary.

▀ SPARK PLUG 1. Remove spark plug.

Load Up 75032 — 7. MAINTENANCE Item Remarks Daily Every 50 hours or every month diagram (page 6)
Fig. 15 · 7. MAINTENANCE Item Remarks Daily Every 50 hours or…
Show 5 more labels / short text on this page
▀ · Air filter · ▀ Fuel filter · Motor oil · ▀ Valve clearance
Page 7 of the Load Up 75032 user manual — 7. MAINTENANCE Item Remarks Daily Every 50 hours or every month
Page 7 · click to enlarge
Page 7
2. Remove carbon deposits. 3. Check for discoloration. Standard: Tan color. 4. Check spark plug gap. 0.7~0.8mm
Load Up 75032 — 7. MAINTENANCE Item Remarks Daily Every 50 hours or every month diagram (page 7)
Fig. 16 · 7. MAINTENANCE Item Remarks Daily Every 50 hours or…
Load Up 75032 — 7. MAINTENANCE Item Remarks Daily Every 50 hours or every month diagram (page 7)
Fig. 17 · 7. MAINTENANCE Item Remarks Daily Every 50 hours or…

AIR FILTER 1. Air filter 2. Wash in solvent 3. Motor oil (SEA #20) 4. Squeege out Never run engine without element.

Page 8 of the Load Up 75032 user manual — factor
Page 8 · click to enlarge
Page 8

REFRESHING THE OIL 1. Start the motor for several minutes and then stop the motor. 2. Remove the oil-level indicator. 3. Place the oil collect can under the motor, unscrew the oil drain plug and drain the oil. 4. Replace the oil drain plug. 5. Fill with fresh oil up to the maximum level. 6. Replace the oil-level indicator. 8. APPLICATION RANGE AC application Model 75032 Power

factor

50 Hz 230 V

2100 W 1

50 Hz 230 V

1600 W 0,7~0,8

50 Hz 230 V

1450 - 1995 W 0,7~0,95

AC output Unit 75032 Rated voltage V 230 V AC Frequency Hz 50 AC current A 9,6

Rated output VA 2100 Max. output VA 2400

Page 9 of the Load Up 75032 user manual — factor
Page 9 · click to enlarge
Page 9
9. TROUBLESHOOTING Engine will not start: 1. Check fuel. Fuel cock to “ON” Clean the filter if necessary. 2. Engine switch to “ON” 3. Check the spark plug 4. If engine still will not start, check following: - Fuel cock clogging - Air filter clogging Or consult your dealer 10. TECHNICAL SPECIFICATIONS Generator

Model 2800 Type self-energizing, 2 poles, 1 phase Frequency 50 Hz Voltage 230 volt AC/12 volt DC AC output continu 2100 W, max. 2400 W/9,6 Amp. DC output 12 volt/10 Amp./120 W Motor

Type 4-stroke, air cooled, 181 cc Fuel Unleaded petrol Fuel tank 15 litres Oil SAE 15W-30 Package

Dimensions (lxwxh) 580 x 438 x 452 mm Weight (empty) 46 kg Order number 75032

Ask about the Load Up 75032

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75032

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75032 manual PDF

44 pages·2.7 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…