SAFETY DEVICES Turn switch to “ON” to reset AC protector. Reduce load within rated output if AC protector (if equipped) turns off. Warning: to prevent electric shocks, the generator must be earthed.




Every 150 hours or every 12 months Spark plug
Remove carbon. Adjust gap. Replace if necessary.
Clean. Replace if necessary.
Clean. Replace if necessary.
▀ Check. ▀
Refresh if necessary: first time after 50 hours.
▀ Fuel hose Check. ▀ Carburetor Check.
Check if necessary.
▀ SPARK PLUG 1. Remove spark plug.




AIR FILTER 1. Air filter 2. Wash in solvent 3. Motor oil 4. Squeege out Never run engine without element.

REFRESHING THE OIL 1. Start the motor for several minutes and then stop the motor. 2. Remove the oil-level indicator. 3. Place the oil collect can under the motor, unscrew the oil drain plug and drain the oil. 4. Replace the oil drain plug. 5. Fill with fresh oil up to the maximum level. 6. Replace the oil-level indicator. 8. APPLICATION RANGE AC application Model 75031/1 Power
50 Hz 230 V
2300 W 1
50 Hz 230 V
1800 W 0,7~0,8
50 Hz 230 V
1600 - 2200 W 0,7~0,95
AC output Unit 75031/1 Rated voltage V 230 V AC Frequency Hz 50 AC current intensity A 10
Rated output VA 2300 Max. output VA 2800 DC tension V 12 DC current tensity A 8,3

Model LB 3000 Type self-energizing, 2 poles, 1 phase Frequency 50 Hz Voltage 230 volt AC = alternate current AC output continu 2300 W, max. 2800 W DC output 12 volt, 8,3 ampere (battery chargers) Motor
Type 4-stroke, air cooled, 6.5 HP Fuel Unleaded petrol Fuel tank 10 litres Oil SAE 15W-40 Package
Dimensions (lxwxh) 578 x 440 x 495 mm Weight (empty) 41 kg Order number 75031/1