SMART THROTTLE Engine speed is kept at idle automatically when the electrical appliance is disconnected and it returns to the proper speed to power of the electrical load when electrical appliance is connected. This position is recommended to minimize the fuel consumption while in operation. Note:
in. - If the oil level is below the end of the dipstick, refill the recommended oil up to
the top of the oil filler neck. Check the oil level regularly, because running the engine with insufficient oil can cause serious engine damage.



4.STARTING THE ENGINE Before starting the engine, disconnect the load from the DC terminals. 1. Turn the fuel cap lever fully clockwise to the ON position.


High altitude operation At high altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase. High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor and readjusting the pilot screws. If you always operate the generator at altitudes higher than 1,500 m (5,000 feel) above sea level, have your authorized dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 305m (1,000 feet increase in altitude. The affect of altitude on the horsepower will be greater than this if no carburetor modification is made. CAUTION Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance,overheating, and serious engine damage caused by an excessively lean air/fuel mixture. 5. USE WARNING:



4.Switch on the equipment to be used. In case of overload operation or when trouble occurs for the equipment being used, the output indicator light (green) will go out, the overload indicator light (red) will light continuously, and no power will be put out. At this time, the engine will not stop, so that the engine must be stopped by setting the respective engine switch to STOP.


accidental contact between a battery terminal and the vehicle's frame or body. CAUTION

Oil alert system The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the oil alert system will automatically shut down the engine (the engine switch will remain in the ON position).



Every year or 300 hrs Check ■ Engine oil
First month or 10 hrs
Every 3 months or 50 hrs
Every 6 months or 100 hrs
Clean ■ (2) Spark plug Clean- adjust
Spark arrester Clean ■ Fuel sediment cup
Fuel tank and strainer
Fuel line Check Every 2 years (replace if neccessary) (3) (1) Log hours of operation to determine proper maintenance. (2) Service more frequently when used in dusty areas. (3) These items should be serviced by an authorized dealer, unless the owner has the proper tools and is mechanically proficient.

1. CHANGING OIL Drain the oil while the engine is still warm to assure rapid and complete draining. CAUTION: Make sure to turn the engine switch and the fuel cap lever OFF before draining. 1. Loosen the cover screw and remove the left side maintenance cover. 2. Remove the oil filler cap. 3. Drain dirty oil into a container thoroughly. 4. Refill with the recommended oil, and check the oil level. 5. Reinstall the left side maintenance cover and tighten the cover screw securely. Engine oil: multigrade SAE 10W-40

Wash your hands with soap and water after handling used oil. NOTE


The gap should be 0.6-0.7 mm (0.024-0.028in). Correct as necessary by carefully bending the side electrode. 7.lnstall the spark plug carefully, by hand, to avoid cross-threading. 8.After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress its washer. If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated. 9.Reinstall the spark plug cap on the spark plug securely. 10.Reinstall the spark plug maintenance cover. CAUTION


the gasoline from the carburetor into a suitable container. c. With the drain screw loosened remove the spark plug cap, and pull the
starter grip 3 to 4 times to drain the gasoline from the fuel pump. d. Turn the engine switch to the OFF position, and tighten the drain screw
securely.


Type inverter converter converter converter inverter inverter Engine 1 cylinder, 4-stroke Start system manual Fuel gasoline, unleaded Cylinder capacity 55 cc 37,7 cc 53,5 cc 100 cc 105 cc 171 cc Cooling system forced air Fuel tank capacity
2,1 litres 1,7 litres 2,1 litres 4,1 litres 4,1 litres 4,8 litres
0,25 litres 0,25 litres 0,25 litres 0,5 litres 0,4 litres 0,6 litres
450x240x 380 412x220x 343 460x248x 395 549x291x 405 549x291x 405 564x367x 453 Weight 14 kg 9 kg 14 kg 22 kg 22 kg 27,5 kg Number of wall sockets
Continu 900 VA 800 VA 1000 VA 1600 VA 1600 VA 2300 VA

Refill the fuel tank. Is there fuel in the tank?
YES
Is the engine switch on? Turn the engine switch on.
YES
Is there enough oil in the engine?
Add the recommended oil.
Is there a spark from the spark plug?
Replace the spark plug.
Take the generator to an authorized dealer.
To check: 1) Remove the spark plug cap and clean any dirt from around the spark plug. 2) Remove the spark plug and install the spark plug in the plug cap. 3) Set the plug side electrode on the cylinder head to ground. 4) Pull the recoil starter, sparks should jump across the gap.
If the engine still does not start, take the generator to an authorized dealer.
Still no spark

Is the output indicator light ON?
YES
Take the generator to an authorized dealer. Is the overload indicator light ON?
YES
Check the electrical appliance or equipment for any defects.
Take the generator to an authorized dealer.
YES
Is DC circuit breaker tripped? Push the reset button.
Take the generator to an authorized dealer. NO


- - - - - - - -

EG-verklaring van overeenstemming Wij, Load Up, postbus 114, 8900 AC Leeuwarden, Nederland, verklaren geheel onder eigen verantwoordelijkheid dat de producten Generatoren 75020-75021-75022-75025-75026-75036 waarop deze verklaring betrekking heeft, in overeenstemming zijn met de volgende normen : EN 60335-1 en EN 60335-2-29 en de richtlijnen : de EMC richtlijn 89/336/EG, de CE marking richtlijn 93/68/EG, de richtlijn 72/23/EG en de richtlijn 2000/14/EG Nederland, Leeuwarden, 17 februari 2005 EG-Konformitätserklärung Wir, Load Up, Postfach 114, 8900 AC, L eeuwarden, Niederlande, erklären ganz auf eigene Verantwortung, dass die Produkte Generatore 75020-75021-75022-75025-75026-75036 auf das sich diese Erklärung bezieht mit den Normen EN 60335-1 und EN 60335-2-29 übereinstimmen und den Richtlinien: EMC Richtlinie 89/336/EC, Richtlinie CE marking 93/68/EC, der Richtlinie 72/23/EC und der Richtlinie 2000/14/EC Niederlande, Leeuwarden, den 17. Februar 2005 EC-declaration of conformity We, Load Up, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the products Generators 75020-75021-75022-75025-75026-75036 to which this declaration refers, comply with the norms EN 60335-1 and EN 60335-2-29 and the directives: EMC directive 89/336/EC, CE marking directive 93/68/EC, the directive 72/23/EC and the directive 2000/14/EC The Netherlands, Leeuwarden, 17th February 2005 Déclaration CE de conformité Nous, Load Up, P.O. Box 114, 8900 AC Leeuwarden, Pays Bas, déclarons entièrement sous notre propre responsabilité que les produits Générateurs 75020-75021-75022-75025-75026-75036 auquel cette déclaration a trait sont conformes aux normes EN 60335-1 et EN 60335-2-29 et aux directives: la directive EMC 89/336/EC, la directive CE marking 93/68/EC, la directive 72/23/EC et la directive 2000/14/EC Pays Bas, Leeuwarden, le 17 février 2005
J.H. de Vries Directeur/Geschäftsführer/Managing director/dDirecteur général/Director gerente


Versie 10.2006
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.