Verse 04.2007 NEDERLANDS 1 ENGLISH 23 Lees deze handleiding voor ingebruikname aandachtig door. Before using the generator, read this instruction manual carefully. ATTENTIVENESS Wanner u de generator af fabriek voor de eerste keep opstart: 3⁄4 olie (SAE 10W-40) afvullen in carter tot de bovenkant van de vulplug. 3⁄4 tank afvullen met ongelode benzine tot anan de markering. 3⁄4 10 – 15 maal het trekmechanisme belienen i.v.m. of brandstofaanvoer naar

Carburettor. ATTENTION When you start the group for the first time: 3⁄4 fill the housing with oil (SAE 10W-40) until it is at the bottom of the container. 3⁄4 fill the tank with unleaded gasoline to the marker. 3⁄4 pull the rope from launcher 10 -15 times to power carburetor. (NL) Afval geproduceerd door elektrische machines mag niet behandeld worden als normal huishoudelijk afval. Zorg voor recycling daar waar passende installaties bestaan. Raadpleeg de plaatselijke instanties of de verkoper voor adviezen over inzameling en verwerking. (F) Electrical waste cannot be treated in the same way as ordinary household refuse. Recycle where appropriate. Contact the competent local authorities or an approved reseller to find out about collection and processing processes.

Importer Load Up, PO Box 114, NL-8900 AC Leeuwarden

www.airpress.nl

Page 3 of the Load Up 75019 user manual — Manual of instructions
Page 3 · click to enlarge
Page 3

FRENCH TABLE OF MATERIALS 1. General page 23 2. Security Instructions page 24 3. Before being used on page 27 4. Start the engine page 29 5. Use page 30 6. Stop Engine page 34 7. Interview page 36 8. Transportation/storage page 41 9. Technical details page 42 10. Page 43 ATTENTION Before using your generator LOAD-UP It is advisable to read this instruction manual carefully, in order to avoid any accidents. 1. GENERAL You just bought a generator. LOAD-UP. Bravo! You now own a highly reliable quality tool that, if properly used and regularly maintained, will perform good work without problems for several years. This instruction manual includes requirements for use and maintenance. Read them carefully before use and ensure that all those called to use the generator also learn about it and observe necessary precautionary measures. The generator was built to generate electricity for sector-operated equipment and appliances or recharge the batteries of automobiles. This device shall be intended solely for use for which it has been specifically designed. Any other use must be considered unfit and therefore unreasonable. The manufacturer cannot be held liable for any damage caused by improper, erroneous or unreasonable uses.

Page 4 of the Load Up 75019 user manual — Manual of instructions
Page 4 · click to enlarge
Page 4
2. Safety requirements The use of generators is hazardous. To mitigate these risks, we have developed a range of security measures. Always follow these instructions and think carefully about what you are doing. This way, you will avoid any accident.
  • The exhaust gas is toxic. Never use the machine inside without adequate ventilation.
  • The exhaust becomes very hot during use and the rest for a while. Let the engine cool before storing it.
  • Gasoline is very flammable. Fill up in a well ventilated area and with the engine at standstill.
  • Do not smoke during filling.
  • Wipe immediately the widespread gasoline.
  • Connecting the generator to a domestic troubleshooting circuit cannot be done only by an approved electrician. The installation shall meet the requirements in force. Poor connections can be very dangerous.
  • To avoid accidents, carefully check the generator before starting it.
  • Put the machine at a minimum distance from a beech or other obstacles. Also respect this distance yourself.
  • The generator must be on a flat surface and upgraded, otherwise you risk fuel leakage.
  • Read this instructions carefully before use, to learn how to use them and stop it in case of emergency.
  • Keep children and other incompetent people at bay.
  • Do not get close to the rotary parts while the engine is running.
  • If you do not use this generator in accordance with the requirements, you may be exposed to an electric shock. Do not touch the device with wet hands.
  • Do not work in the rain or under snow, as the machine cannot get wet.
  • CAUTION: The instructions, precautions and warnings presented in this manual cannot address all possible conditions and situations. It is the user's responsibility to exercise common sense, caution and care when using the generator.
  • Allow the generator to be used only by those who have become aware of this instruction. The use of the generator by uninitiated people is dangerous.
Page 5 of the Load Up 75019 user manual — COMPONENTS
Page 5 · click to enlarge
Page 5

COMPONENTS

Page 6 of the Load Up 75019 user manual — CONTROL PANEL
Page 6 · click to enlarge
Page 6

CONTROL PANEL

Page 7 of the Load Up 75019 user manual — CONTROL PANEL
Page 7 · click to enlarge
Page 7
3. BEFORE THE SERVICE Check the generator on a flat, power-absorbed floor. 1. Check oil level Recommended oil: 10W-40 (motor oil). - Unscrew the screw and defeat the left cap (left side maintenance cover). - Remove the gauge and clean it with a clean cloth. - Check the oil level by re-dipping the gauge (do not screw it). - When the oil level is lower than the tip of the gauge, fill

the housing until it is orifice. Perform this check regularly, too little oil can seriously damage the engine. Attention: the oil control system automatically stops the engine when the oil level drops below its limit. However, it is advisable to check the level regularly so as not to cause unintentional engine shutdown. 2. Control the level of petrol

Page 8 of the Load Up 75019 user manual — CONTROL PANEL
Page 8 · click to enlarge
Page 8

− Use unleaded gasoline.

− If necessary, fill up the mark.

− In no case shall a mixture of petrol/oil or dirty gasoline be used.

− Avoid dropping dirt, dust or water into the tank.

− Close the cap tightly after filling. Warning:

  • Gasoline is extremely flammable and in some circumstances even explosive.
  • Always fill up in a well ventilated place and with stationary engine. Do not smoke, spark or fire where you are filling up or storing gasoline.
  • Do not fill the tank too much (do not exceed the mark). Close the cap tight.
  • Don't waste gas by filling up. Gasoline and vapours can ignite. Clean it thoroughly before starting the engine.
  • Avoid contact with skin or gas inhalation as much as possible. KEEP THE KIDS AWAY. 3. Check the air filter Regularly check the air filters for cleanliness and good condition. Unscrew the screw and remove the left-hand maintenance lid. Press the lock over the filter holder and remove the lid. Check the cartridge and clean or replace it if necessary. WARNING Do not run the engine without air filter. Dust and dirt can be sucked into the engine and damaged. CAUTION Turn the fuel stopper purging on OFF before moving the generator.
Page 9 of the Load Up 75019 user manual — CONTROL PANEL
Page 9 · click to enlarge
Page 9
4. END THE MOTOR Always disconnect the DC output before starting the engine. 1. Turn the gas stopper purging button in a clockwise direction on ON. 2. Turn the engine switch on ON. 3. Close the CLOSED Choke lever.
Page 10 of the Load Up 75019 user manual — CONTROL PANEL
Page 10 · click to enlarge
Page 10

when the engine starts to turn. ATTENTION When the engine is squeezing and no longer wants to start, check the oil level before checking out the faults section. 5. USE WARNING:

  • To avoid shock caused by defective electrical appliances, the generator must be grounded. Provide a large section cable between the earthing terminal and any outside ground.
  • Connecting the generator to a domestic troubleshooting circuit cannot be done only by an approved electrician. The installation shall meet the requirements in force. Poor connection can cause the current to return and electrocute the manipulator. In addition, when the power failure is resolved, the generator can explode and cause a fire. 1/AC applications 1. Start the engine and make sure that the green indicator is on. 2. Turn off the switch from the unit before plugging it.
Page 11 of the Load Up 75019 user manual — CONTROL PANEL
Page 11 · click to enlarge
Page 11

Output and overload power tell-tales The output power indicator (green) remains on while the assembly is operating normally. In case of overloading the generator (more than 1.0 kVA) or when connected device stops, green indicator is turned off, red light is switched on and current cut. Stop the engine and look for cause of overload.

  • Check the correct operating condition of the device before connecting it to the generator. Start the engine and plug it in. 2/Application DC The DTC case is used only to charge 12 volt batteries for automobiles.
  • Turn the switch on OFF.
  • To avoid a tingling close to the battery, first plug in the DC case side and then the battery clamps. To unplug, do the opposite.
  • Before connecting the cables to a battery mounted in a car, disconnect the mass cable from the battery. Do not hand them over until you unplug the charger. So you will not risk causing a short circuit by mistakenly making contact between the chassis of the car and the phase.
  • Do not reverse the polarities of cables, but connect identical poles (+ and -), otherwise you risk seriously damaging the battery or even generator. Note:
  • The DC housing can be used while you are using AC current. Turn the switch on OFF.
Page 12 of the Load Up 75019 user manual — WARNING
Page 12 · click to enlarge
Page 12
  • DC current switch switches power off when a certain limit is reached. In this case, please wait a few minutes before sinking again.

WARNING

  • An electrolytic battery produces explosive gases; avoid sparking and smoking in the vicinity. Provide sufficient ventilation during the load.
  • These batteries contain sulphuric acid (electrolyte). Contact with the skin can cause serious burns. Wear protective clothing and a mask all the time. - At the slightest contact with skin, rinse thoroughly with running water. - Do the same for at least 15 minutes in case of contact with eyes and contact a doctor.
  • Electrolyte is toxic. - If you are inadvertently swallowing it, drink large amounts of water or milk followed by magnesium milk or vegetable oil and contact a doctor.
  • KEEP THE KIDS AWAY.
Page 13 of the Load Up 75019 user manual — WARNING
Page 13 · click to enlarge
Page 13

Control lamp too little oil This lamp warns you when it is too little oil in the housing and there is a risk of damaging the engine. The guard system will shut off the engine before oil levels fall below minimum level (the motor switch remains on ON, however). ATTENTION:

  • Do not allow the engine to run at full load for more than 30 minutes. Do not exceed the engine capacity when working continuously. Always take into account the total wattage of connected devices.
  • Do not exceed the limit of the contact box.
  • Do not use this device to feed a domestic circuit. This can cause damage to the generator and connected devices.
  • The generator may not be transformed or used for any other purpose for which it was designed. When using, consider the following: - Do not connect generators in parallel. - Do not extend the exhaust.
  • N-Use only flexible cables with thick rubber insulation.
  • Maximum length of the extension: 60 m for 1.5 mm2 and 100 m cables for 2.5 mm2 cables.
  • Do not place the generator near other electrical circuits under tension. BEWARE
  • A large and permanent overload (red witness is constantly on) can damage the generator. Regular overload, even interrupted (red control lit from time to time), can reduce the generator's longevity.
  • Control the proper functioning of each device you want to plug in. When a device does not function properly, too slowly or interrupted, immediately stop the generator. Then remove the plug and check the device.
Page 14 of the Load Up 75019 user manual — WARNING
Page 14 · click to enlarge
Page 14
6. CUT THE MOTOR In case of emergency, to stop the engine you can turn the switch on OFF. IN NORMAL CASES: 1. Turn off the switches on connected devices and remove the plug. 2. Turn the motor switch to STOP. Turn the gasoline switch to OFF.
Page 15 of the Load Up 75019 user manual — WARNING
Page 15 · click to enlarge
Page 15
3. Turn the tank cap purging countersense from a clock to OFF. PRUDENCE Do not miss to perform these two actions before stopping the generator, prior to transporting it and before storing.
Page 16 of the Load Up 75019 user manual — WARNING
Page 16 · click to enlarge
Page 16
7. MAINTENANCE A regular maintainer of your generator guarantees its efficiency and longevity. Take care to read carefully the maintenance requirements below. WARNING
  • Turn off the engine before performing maintenance work. In some cases, the engine must remain running. Check the place for air. Lez exhaust gas is toxic. CAUTION N Other parts can damage the generator. SCHEMA DIENTRETIEN Normal maintenance period (1)

Annual or 300 hours Checker ■ Engine oil

3 months or 50 hours

6 months or 100 hours

  • Replace
  • Control
  • Air filter

Clean ■ (2) Clean Candle- Set

Cleaner collector ■ Fuel filter

  • (3)

Control If necessary, replace every 2 years (3)

(1) Recommended period. (2) Clean more often when the machine is running in a dusty place. (3) To be performed by an approved distributor, unless the porprietaire has special tools and sufficient technical knowledge.

Show 9 more labels / short text on this page
Daily 1 month or 10 hours · ■ · Control ■ · Valve setting · Control- adjust · Tank and sieve · Clean ■ (3) · Fuel driving
Page 17 of the Load Up 75019 user manual — WARNING
Page 17 · click to enlarge
Page 17

1. DRAIN OIL To promote a rapid and complete discharge, the drain must be done with hot motor. ATTENTIONCheck if the engine switch and gas purging unit are in OFF position before oil is discharged. 1. Unscrew the screw by removing the left-hand care cap. 2. Remove the filler cap. 3. Completely drain oil into an appropriate container. 4. Fill with the appropriate oil by checking the level. 5. Put the cap up and screw it. Car case oil: 0.25 l motor oil (SAE 10W-40 multigrade)

Page 18 of the Load Up 75019 user manual — WARNING
Page 18 · click to enlarge
Page 18

After draining, take care to wash your hands thoroughly with water and soap. ATTENTION

  • Recycle the oil under existing laws. Do not pour it into sewers or on the ground! 2. FILTER DISHING A dirty oil filter will reduce air flow to the carburettor, causing malfunction. Clean the air filter regularly. Do it more often when the generator is running in a dusty place. WARNING
  • Do not use gasoline or other flammable liquid to clean the filter (danger explosion).
1. Unscrew the screw by removing the left-hand care cap. 2. Thread the restraint tab and remove the lid from the filter. 3. Wash the element in a liquid that is not flammable and let it dry.
Page 19 of the Load Up 75019 user manual — WARNING
Page 19 · click to enlarge
Page 19
  • 4. Impregnate the clean engine oil element and twist it thoroughly. 5. Put the element back in place, as well as its lid. 6. Put the latter back in both ends of the bottom into holes, then push away the restraint tab. 7. Put the left-hand maintenance lid back on and rework it. 3. CANDLE RECOMMENDED: CR5H88 (NGK). To function properly, the distance between electrodes must be correct and the candle must be clean.
  • Untie the lid.
  • Remove the connection cap.
Page 20 of the Load Up 75019 user manual — WARNING
Page 20 · click to enlarge
Page 20
  • Scrap the upper part of the candle.
  • Unscrew it with a candle key.
  • Check the candle. Replace it if the insulation is cracked or broken. If she is
  • Reusable, clean it with a metal wire brush.
  • Measure the distance between electrodes using a gauge of thickness.
  • The distance shall be 0.6 mm to 0.7 mm. If necessary, correct this
  • distance by folding gently the electrode.
  • Gently re-screw the candle from your fingers without damaging the net.
  • Then tighten the candle for a quarter of a turn with a key to compress
  • The seal ring.
  • For a new candle, one quarter or an eighth of the turn is enough.
  • Deepen the contact cap.
  • Put the lid back on. CAUTION
  • The candle must be firmly tightened. A poorly tight candle may overheat, causing damage to the motor head.
  • Never use candles with an erroneous thermal degree. 4. COLLECTOR/SCRATCH
Page 21 of the Load Up 75019 user manual — WARNING
Page 21 · click to enlarge
Page 21
  • WARNING: When a generator turns, the exhaust becomes extremely hot. Let it cool before you continue. CAUTION: To ensure the collector's efficiency, it must be checked and cleaned every 100 hours.
  • Decarbonize the collector with a metal brush.
  • Check the exhaust and replace it if necessary. 8. TRANSPORT/CHANGE In order to avoid fuel loss during transport or storage, the engine must be placed straight with the motor switch in OFF position. Close the cap drainer of the container by turning in reverse direction (OFF position). WARNING: During transport, the following points must be taken into account:
  • Check if there is too much fuel in the tank (it cannot be found gas in the filling opening).
  • Do not let the generator run on a vehicle, but on firm ground and in well ventilated areas.
  • When you put it in a vehicle, be careful not to place it under direct sunlight. After a few hours, high temperatures will cause gas vapours that can lead to deflagration.
  • When transporting the generator, do not drive for too long on a bumpy road. If necessary, empty the tank. When storing the group for a long time, follow these points: 1. The warehouse must be dry and dust free. 2. Empty the gas tank. WARNING: In some circumstances, gasoline becomes extremely flammable and explosive. Do not smoke too close to the generator and do not approach with fire or sparks. a. To transfer fuel from the tank, use a licensed jerrycan. b. Turn the motor switch on ON, unscrew the carburettor purgator and

Transfer the gasoline to a suitable container. c. While leaving the purger unscrewed, pull the contact plug from the candle

and pull the launcher handle 3 to 4 times to empty the fuel pump. d. Put the motor switch back on OFF and re-screw firmly. e. Change the engine oil.

Page 22 of the Load Up 75019 user manual — WARNING
Page 22 · click to enlarge
Page 22

f. Unscrew the candle and pour a clean oil teaspoon into the

cylinder. Turn the engine around a few turns by hand to spread oil and re-screw the candle. g. Slowly pull the handle of the launcher until the first resistance. This

the piston is mounted and the inlet and outlet valves are closed. By tidying the machine in this way, the engine is unlikely to rust. 9. TECHNICAL DATA Reference 75019 Model LB 1000-i inverter Engine 1.8 CV/1.3 kW/4-stroke/1 cylinder Cylinder capacity 54 cc Compression 8.0:1 Engine speed 5500 rpm Forced air cooling Carcase content 0.25 litres Fuel tank contents 2.8 liters Unleaded petrol Candle A7RTC Sound level (ISO 8528-10) 60 dB(A) Dimensions (w x h) 476 x 248 x 389 mm Weight 14.5 kg AC output Voltage 230 V Frequency 50 Hz Nominal output power 900 VA Maximum output power 1000 VA DC output Voltage 12 V DC current 8.3 A

Only for charging 12 volt batteries for cars.

Page 23 of the Load Up 75019 user manual — NON
Page 23 · click to enlarge
Page 23
10. PANNES The machine does not want to start:

Adding gasoline Is there enough gas in the tank?

NON

OUI

Is the switch on ON? Put it on ON.

NON

OUI

NON

Is there enough oil in the crankcase?

Add appropriate oil.

OUI

Does the spark candle?

NON

Replace the candle.

Return the generator to a service after approved sale.

Check: 5) Remove the cap and clean the candle. 6) Unscrew the candle and push the cap. 7) Make contact between the mass of candle and head. 8) Pull the handle of the launcher: sparks must appear.

If the engine still does not want to start, return the generator to a service after approved sale.

You're not gonna be the one.

Page 24 of the Load Up 75019 user manual — OUI
Page 24 · click to enlarge
Page 24
The machine doesn't workNo DC power on the contact:

Is the green indicator on?

NON

OUI

Is the red witness on?

Return the generator to a service after approved sale.

NON

OUI

Control the correct operation of the appliance or electrical tool.

Return the generator to a service after approved sale.

NON

  • Replace or repair the electrical apparatus.
  • Return the generator to a service after approved sale.

OUI

Did the DC fuse jump? Push the reset button.

OUI

NON

Return the generator to a service after approved sale.

Page 25 of the Load Up 75019 user manual — NON
Page 25 · click to enlarge
Page 25
Page 25 of the Load Up 75019 user manual — NON
Page 26 of the Load Up 75019 user manual — NON
Page 26 · click to enlarge
Page 26
Page 26 of the Load Up 75019 user manual — NON
Page 27 of the Load Up 75019 user manual — NON
Page 27 · click to enlarge
Page 27
Load Up 75019 — NON diagram (page 27)
Fig. 2

- - - - - - - -

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Load Up 75019

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75019

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75019 manual PDF

52 pages·2.3 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…