  • Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building’s electrical system.
  • Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage.
  • Place the generator at least 1 m away from buildings or other equipment during operation.
  • Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
  • Use the generator in a clean and dust free area.
  • Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions.
  • Keep children and pets away from the generator when it is in operation.
  • Keep away from rotating parts while the generator is running.
  • The generator is a potential source of electrical shocks when misused; do not operate with wet hands.
  • Do not operate the generator in rain or snow and do not let it get wet. CONTROL PANEL
Load Up 75012 diagram (page 2)
Fig. 1
Page 3 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 3 · click to enlarge
Page 3

COMPONENT IDENTIFICATION

Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 3)
Fig. 2
Page 4 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 4 · click to enlarge
Page 4
3. PRE-OPERATION CHECK 1. Check the fuel level - Use automotive 2-stroke gasoline. - If the fuel level is low, refuel the fuel tank until the level as specified. - Never use dirty gasoline. - Avoid getting dirt, dust or water in the fuel tank. - After refuelling, tighten the fuel filler cap securely. Warning:
  • Gasoline is extremely flammable and is explosive under certain conditions.
  • Refuel 2-stroke gasoline in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refuelled or where gasoline is stored.
  • Do not overfill the fuel tank (there should be no fuel above the upper limit mark). After refuelling, make sure the tank cap is closed properly and securely.
  • Be careful not to spill 2-stroke fuel when refuelling. Spilled 2-stroke fuel or fuel vapour may ignite. If any 2-stroke fuel is spilled, make sure the area is dry before starting the engine.
  • Avoid repeated or prolonged contact with skin or breathing of vapour. KEEP OUT OF REACH OF CHILDREN. 2. Check the air cleaner Check the air cleaner element to be sure it is clean and in good condition. Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, check the element. Clean or replace the element if necessary. CAUTION
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 4)
Fig. 3
Page 5 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 5 · click to enlarge
Page 5

Never run the engine without the air cleaner. Rapid engine wear will result from contaminants, such as dust and dirt, being drawn through the carburettor, into the engine.

Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 5)
Fig. 4
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 5)
Fig. 5
Page 6 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 6 · click to enlarge
Page 6
3. Move the choke lever to the CLOSED position and open the fuel valve. NOTE Do not use the choke when the engine is warm or the air temperature is high. 4. Pull the starter grip until resistence is felt, then pull the starter grip briskly. CAUTION Do not allow the starter grip to snap back. Return it slowly by hand. 5. Move the choke lever to the RUN position as the engine warms up. High altitude operation
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 6)
Fig. 6
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 6)
Fig. 7
Page 7 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 7 · click to enlarge
Page 7

At high altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase. High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor and readjusting the pilot screws. If you always operate the generator at altitudes higher than 1,500 m (5,000 feel) above sea level, have your authorized dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 305m (1,000 feet increase in altitude. The affect of altitude on the horsepower will be greater than this if no carburetor modification is made. CAUTION Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance,overheating, and serious engine damage caused by an excessively lean air/fuel mixture. 5. USE WARNING:

  • To prevent electrical shock from faulty appliances, the generator should be <a href="http://grounded.Co" rel="nofollow noopener" target="_blank">grounded.Co</a>nnect a length of heavy wire between the generator's ground terminal and an external ground source.
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 7)
Fig. 8
  • Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored. the generator may explode, burn, or cause fires in the building's electrical system. CAUTION:
Page 8 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 8 · click to enlarge
Page 8
  • Limit operation requiring maximum power to 30 minutes. For continuous operation, do not exceed the rated power. In either case, the total wattage of all appliances connected must be considered.
  • Do not exceed the current limit specified for any one receptacle.
  • Do not connect the generator to a household circuit. This could cause the damage to the generator or to electrical appliances in the house.
  • Do not modify or use the generator for other purposes than it is intended for. Also observe the following when using the generator. - Do not connect generators in parallel. - Do not connect an extension to the exhaust pipe.
  • When an extension cable is required, be sure to use a tough rubber sheathed flexible cable.
  • Limit length of extension cables; 60 m for cables if 1.5 mm² and 100 m for cabes of 2.5 mm².
  • Keep the generator away from other electric cables or wires such as commercial power supply lines. NOTE:
  • The DC receptacle can be used while the AC power is in use. If you use both at the same time, be sure not to exceed the total power for AC and DC.
  • Most appliance motors require more than their rated wattage for start-up. AC applications 1. Start the engine and make sure the output indicator light (green) comes on. 2. Confirm that the appliance to be used is switched off, and plug in the appliance. CAUTION
  • Substantial overloading may damage the generator. Marginal overloading may shorten the service life of the generator.
  • Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the generator engine switch immediately. Then disconnect the appliance, and examine it for signs of malfunction. Output and Overload Indicators The output indicator light (green) will remain ON during normal operating conditions. If the generator is overloaded (in excess of 0,65 kVA), or if there is a short in the connected appliance, the output indicator light (green) and the overload protection will go out. Current to the connected appliance will be shut off. Stop the engine and investigate the overload source.
Page 9 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 9 · click to enlarge
Page 9
  • Before connecting an appliance to the generator, check that it is in good order, and that its electrical rating does not exceed that of the generator. Then start the engine and connect the power cord of the appliance. 1. Connect the ground terminal.
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 9)
Fig. 9
2. Start the engine according to "STARTING THE ENGINE". 3. Confirm that the equipment to be used is switched off, and insert the plug of the equipment to be used into the AC receptacle. CAUTION
  • Confirm that the use equipment to be connected is switched off.
  • When the equipment to be used is switched on, it will operate suddenly, and injuries or accidents may be caused. 4.Switch on the equipment to be used. In case of overload operation or when trouble occurs for the equipment being used, the output indicator light (green) will go out, and the overload protection will switch the power off. At this time, the engine will not stop, so that the engine must be stopped by setting the respective engine switch to STOP.
Page 10 of the Load Up 75012 user manual — COMPONENT IDENTIFICATION
Page 10 · click to enlarge
Page 10

The DC receptacle may be used for charging 12 volt automotive-type batteries only. 1.Connect the charging cables to the DC receptacle of the generator and then to the battery terminals. WARNING

Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 10)
Fig. 10
Load Up 75012 — COMPONENT IDENTIFICATION diagram (page 10)
Fig. 11
  • To prevent the possibility of creating a spark near the battery, connect charging cable first to the generator, then to the battery. Disconnect cable first at the battery.
  • Before connecting charging cables to a battery that is installed in a vehicle, disconnect the vehicles grounded battery cable. Reconnect the vehicle's grounded battery cable after the charging cables are removed. This procedure will prevent the possibility of a short circuit and sparks if you make accidental contact between a battery terminal and the vehicle's frame or body.
Page 11 of the Load Up 75012 user manual — CAUTION
Page 11 · click to enlarge
Page 11

CAUTION

  • Do not attempt to start an automobile engine with the generator still connected to the battery. The generator may be damaged.
  • Connect the positive battery terminal to the positive charging cord. Do not reverse the charging cables, or serious damage to the generator and/or battery may occur. WARNING
  • The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventiIation when charging.
  • The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns. Wear protective clothing and a face shield. - If electrolyte gets on your skin, flush with water. - If electrolyte gets in your eyes, flush with water for at least 15 minutes and call a physician.
  • Electrolyte is poisonous. - If swallowed,drink large quantities of water or milk and follow with milk of magnecia or vegetable oil and call a physician.
  • KEEP OUT OF REACH OF CHILDREN. 2.Start the engine.
  • The DC receptacle may be used while the AC power is in use.
  • An overload DC circuit will trip the DC circuit protector. If this happens, wait a few minute before pushing in the circuit protector to resume operation. It is advised to charge the new generator the first 20 hours for only 50%. 6. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch to the OFF position. IN NORMAL USE: 1. Switch off the connected equipment and pull the inserted plug. 2. Turn the engine switch to the OFF position.
Page 12 of the Load Up 75012 user manual — CAUTION
Page 12 · click to enlarge
Page 12
Load Up 75012 — CAUTION diagram (page 12)
Fig. 12
3. Turn the cap lever fully counterclockwise to the “OFF” position. CAUTION Be sure the fuel cap lever and the engine switch are “OFF” when stopping, transporting and/or storing the generator. 7. MAINTENANCE
Load Up 75012 — CAUTION diagram (page 12)
Fig. 13
Page 13 of the Load Up 75012 user manual — CAUTION
Page 13 · click to enlarge
Page 13

The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition. WARNING

  • Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas. CAUTION Use genuine parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator. MAINTENANCE SCHEDULE Regular service period (1) Each

Every year or 300 hrs Check ■ Air cleaner

First month or 10 hrs

Every 3 months or 50 hrs

Every 6 months or 100 hrs

Clean ■ (2) Spark plug Clean- adjust

Fuel tank and strainer

Fuel line Check Every 2 years (replace if neccessary) (3) (1) Log hours of operation to determine proper maintenance. (2) Service more frequently when used in dusty areas. (3) These items should be serviced by an authorized dealer, unless the owner has the proper tools and is mechanically proficient. 1. AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburettor. To prevent carburettor malfunction, service the air cleaner regularly. Service more frequently when

Show 5 more labels / short text on this page
use · ■ · Fuel sediment cup · Check ■ · Clean ■ (3)
Page 14 of the Load Up 75012 user manual — CAUTION
Page 14 · click to enlarge
Page 14

operating the generator in extremely dusty areas. Subsequently use the generator in a dry, dust free area. WARNING

  • Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions. 1. Remove the right side maintenance cover. 2. Press the latch tab on the top of the air cleaner body, and remove the air cleaner cover. 3. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. 4. Soak the element in clean engine oil and squeeze out the excess oil. 5. Reinstall the air cleaner element and the cover. 6. Reinstall the air cleaner cover by inserting the lower tabs, and the latch tab. 7. Reinstall the right side maintenance cover 2. SPARK PLUG SERVICE RECOMMENTDED SPARK PLUG: FGRTC

To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1.Remove the spark plug maintenance cover.

Load Up 75012 — CAUTION diagram (page 14)
Fig. 14
Page 15 of the Load Up 75012 user manual — CAUTION
Page 15 · click to enlarge
Page 15
2. Remove the spark plug cap. 3. Clean any dirt from around the spark plug base. 4. Use the wrench to remove the spark plug.
Load Up 75012 — CAUTION diagram (page 15)
Fig. 15

5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 6.Measure the plug gap with a feeler gauge. The gap should be 0.6-0.7 mm (0.024- 0.028in). Correct as necessary by carefully bending the side electrode. 7.lnstall the spark plug carefully, by hand, to avoid cross-threading. 8.After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress its washer.

Load Up 75012 — CAUTION diagram (page 15)
Fig. 16
Page 16 of the Load Up 75012 user manual — CAUTION
Page 16 · click to enlarge
Page 16

If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated. 9.Reinstall the spark plug cap on the spark plug securely. 10.Reinstall the spark plug maintenance cover. CAUTION

  • The spark plug must be securely tightened. An improperly tightened plug can become very hot and possibly damage the generator.
  • Never use a spark plug with an improper heat range. 8. TRANSPORTING/STORAGE To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position, with the engine switch OFF. Turn the cap lever fully counter clockwise to the "OFF” position. WARNING: when transporting the generator:
  • Do not overfill the tank (there should be no fuel in the filler neck).
  • Do not operate the generator while it is on a vehicle. Take the generator off the vehicle and use it in a well ventilated place.
  • Avoid a place exposed to direct sunlight when putting the generator on a vehicle. If the generator is left in an enclosed vehicle for many hours, high temperature inside the vehicle could cause fuel to vaporize resulting in a possible explosion.
  • Do not drive on a rough road for an extended period with the generator on board. If you must transport the generator on a rough road, drain the fuel from the generator beforehand. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain out the fuel completely. WARNING : gasoline is extremely flammable and explosive under certain conditions. Do not smoke or allow flames or sparks in the area. 9. TECHNICAL SPECIFICATIONS Article no.

Type Converter

Page 17 of the Load Up 75012 user manual — CAUTION
Page 17 · click to enlarge
Page 17

Motor 1 cylinder 2 stroke Start system Manual Fuel 2 stroke gasoline, unleaded Cylinder capacity 63 cc Cooling system Forced air Fuel tank capacity 2 litres

Noise level dB(A)/7 m

Weight 19.5 kg Number of wall sockets

Output (Volt/Hz/A/kVA)- AC - DC

230/50/0.65 12/8.3

Output (max. KVA)

Fuel consumption +/- 650 gr. per hour Continue 650 VA

Dimensions (LxWxH) mm · 470x250x440 · 0,8

Page 18 of the Load Up 75012 user manual — NO
Page 18 · click to enlarge
Page 18
10. TROUBLE SHOOTING When the engine will not start:

Refill the fuel tank. Is there fuel in the tank?

NO

YES

Is the engine switch on? Turn the engine switch on.

NO

YES

Is there a spark from the spark plug?

NO

Replace the spark plug.

Take the generator to an authorized dealer.

To check: 1) Remove the spark plug cap and clean any dirt from around the spark plug. 2) Remove the spark plug and install the spark plug in the plug cap. 3) Set the plug side electrode on the cylinder head to ground. 4) Pull the recoil starter, sparks should jump across the gap.

If the engine still does not start, take the generator to an authorized dealer.

Still no spark

Page 19 of the Load Up 75012 user manual — YES
Page 19 · click to enlarge
Page 19
Appliance does not operateNo electricity at the Dc receptacle:

Is the output indicator light ON?

NO

YES

Reset. Overheat protection switched off?

NO

YES

Check the electrical appliance or equipment for any defects.

Take the generator to an authorized dealer.

NO

  • Replace the electrical appliance or equipment.
  • Take the electrical appliance or equipment to an electrical shop for repair.

YES

YES

Is DC circuit breaker tripped? Push the reset button.

Take the generator to an authorized dealer. NO

Page 20 of the Load Up 75012 user manual — NO
Page 20 · click to enlarge
Page 20
Load Up 75012 — NO diagram (page 20)
Fig. 17

- - - - - - - -

Page 22 of the Load Up 75012 user manual — NO
Page 22 · click to enlarge
Page 22

EG-verklaring van overeenstemming Wij, Load Up, postbus 114, 8900 AC Leeuwarden, Nederland, verklaren geheel onder eigen verantwoordelijkheid dat het product Generator 75012 waarop deze verklaring betrekking heeft, in overeenstemming zijn met de volgende normen : EN 60335-1 en EN 60335-2-29 en de richtlijnen : de EMC richtlijn 89/336/EG, de CE marking richtlijn 93/68/EG, de richtlijn 72/23/EG en de richtlijn 2000/14/EG Nederland, Leeuwarden, 14 mei 2009 EG-Konformitätserklärung Wir, Load Up, Postfach 114, 8900 AC, L eeuwarden, Niederlande, erklären ganz auf eigene Verantwortung, dass Produkt Generator 75012 auf das sich diese Erklärung bezieht mit den Normen EN 60335-1 und EN 60335-2-29 übereinstimmen und den Richtlinien: EMC Richtlinie 89/336/EC, Richtlinie CE marking 93/68/EC, der Richtlinie 72/23/EC und der Richtlinie 2000/14/EC Niederlande, Leeuwarden, den 14 Mai 2009 EC-declaration of conformity We, Load Up, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the product Generator 75012 to which this declaration refers, comply with the norms EN 60335-1 and EN 60335-2-29 and the directives: EMC directive 89/336/EC, CE marking directive 93/68/EC, the directive 72/23/EC and the directive 2000/14/EC The Netherlands, Leeuwarden, 14th May 2005 Déclaration CE de conformité Nous, Load Up, P.O. Box 114, 8900 AC Leeuwarden, Pays Bas, déclarons entièrement sous notre propre responsabilité que les produit Générateur 75012 auquel cette déclaration a trait sont conformes aux normes EN 60335-1 et EN 60335-2-29 et aux directives: la directive EMC 89/336/EC, la directive CE marking 93/68/EC, la directive 72/23/EC et la directive 2000/14/EC Pays Bas, Leeuwarden, le 14 mai 2009

E.J. de Vries Directeur/Geschäftsführer/Managing director/dDirecteur général/Director gerente

Load Up 75012 — NO diagram (page 22)
Fig. 18
Page 23 of the Load Up 75012 user manual — GENERATORE GENERATORS
Page 23 · click to enlarge
Page 23

Gebrauchsanleitung Instruction manual

Versie 05.2009

GENERATORE GENERATORS

Load Up 75012 — GENERATORE GENERATORS diagram (page 23)
Fig. 19
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Load Up 75012

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75012

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75012 manual PDF

44 pages·3.4 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…