Page 1 of the Liftmaster 2000SDR user manual — Owner's Manual
Page 1 · click to enlarge
Page 1
Liftmaster 2000SDR — Owner's Manual diagram (page 1)
Fig. 1 · Owner's Manual

The Chamberlain Group, Inc. A DUCHOSSOIS ENTERPRISE 845 Larch Avenue Elmhurst, Illinois 60126-1196

Complies with UL 325 regulations effective January 1, 1993 ®

I Please read this manual and the enclosed safety materials carefully!

I Fasten the manual near the garage door after installation.

I The door WILL NOT CLOSE unless the Protector System® is connected and properly

I Periodic checks of the opener are required to ensure safe operation.

I The model number label is located on the back of your opener.

Page 3 of the Liftmaster 2000SDR user manual — Hardware Supplied
Page 3 · click to enlarge
Page 3

Safety Information and Precautions

WARNING CAUTION CAUTION

An unbalanced garage door might not reverse when required and someone under the door could be seriously injured or killed. If your garage door binds, sticks or is out of balance, call for professional garage door service. Garage doors, door springs, cables, pulleys, brackets, and their hardware are under extreme tension and can cause serious injury or death. Do not try to loosen, move or adjust them yourself! Ropes left on a garage door could cause someone to become entangled and killed. Remove all ropes connected to the door before installing and operating the opener.

To avoid damage to the garage door and opener, disable locks before installing and operating the opener. Use a wood screw or nail to hold locks in the "open" (unlocked) position. Operation at other than 120V 60 Hz will cause opener malfunction and damage.

Hardware Supplied

Identify the type and height of your door, any special conditions that exist, and any additional materials that may be required.

Coupling Sleeve (1) Hex Screw 1/4"-20 x 5/8" (4) Nut 1/4" - 20 (4)

  • Test Your Door for Balance Before you begin, complete the following test to make sure your door is balanced, and is not sticking or binding:
  • Lift the door about halfway as shown. Release the door. It should stay in place, supported entirely by its springs.
  • Raise and lower the door to see if there is any binding or sticking.

Hex Screw 5/16"-18 x 7/8" (4) Lag Screw 5/16"-9 x 1-5/8" (2) Lag Screw 5/16"-18 x 1-7/8" (2) Carriage Bolt 5/16"-18 x 2-1/2" (2) Clevis Pin 5/16" x 2-3/4" (1) Clevis Pin 5/16" x 1-1/4" (1) Clevis Pin 5/16" x 1" (1) Nut 5/16" - 18 (6) Lock Washer 5/16" (6) Screw 6AB x 1-1/4" (2) Screw 6-32 x 1" (2) Insulated Staples (10) Ring Fastener (3) Handle Dry Wall Anchors (2) Rope

SECTIONAL DOORSectional Door One-Piece DoorONE-PIECE DOOR

Carriage Bolts 1/4" - 20 x 1/2" (2) Wing Nut (2) Insulated Staples (20)

Show 4 more labels / short text on this page
Rail Assembly · Opener Installation · Safety Reversing Sensor · Installation
Page 4 of the Liftmaster 2000SDR user manual — Opener Carton Inventory
Page 4 · click to enlarge
Page 4
Liftmaster 2000SDR — Opener Carton Inventory diagram (page 4)
Fig. 2 · Opener Carton Inventory

Your garage door opener is packaged in two cartons which contain the power unit and parts illustrated below. Accessories will depend on model purchased. If anything is missing, carefully check the packing material. Parts may be "stuck" in the foam. KEEP THE FOAM INTACT (see page 6). Hardware is listed on page 3.

(2) Safety Reversing Sensors (1 Sending Eye and 1 Receiving Eye)

Page 5 of the Liftmaster 2000SDR user manual — Sectional Door Installation
Page 5 · click to enlarge
Page 5
Liftmaster 2000SDR — Sectional Door Installation diagram (page 5)
Fig. 3 · Sectional Door Installation

Before you begin, survey your garage area to see whether any of the conditions below apply to your installation.

Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.).

You may find it helpful to refer back to this page as you proceed with the installation of your opener.

Page 6 of the Liftmaster 2000SDR user manual — Assembly Section: Pages 6 - 7
Page 6 · click to enlarge
Page 6

As illustrated above, slide the trolley onto and along the bottom of the rail until it snaps firmly in place. Be certain to install it facing correctly: the trolley release arm must be horizontal (lock position), with its arrow pointed away from the power unit.

  • Working on a level surface, align the rail assembly with the power unit, as shown.
  • Slip the coupling over the rail sprocket.
  • Slide the rail through the power unit bracket until the coupling fits securely over the power unit sprocket.
  • Align the two screw holes in the rail with those in the power unit bracket. Insert two 1/4"-20x5/8" hex screws and lock nuts. Tighten securely with a 7/16" socket wrench.

ASSEMBLY STEP 2 Install the Trolley

ASSEMBLY STEP 1 Fasten the Rail To the Power Unit

Liftmaster 2000SDR — ASSEMBLY STEP 2 Install the Trolley diagram (page 6)
Fig. 4 · ASSEMBLY STEP 2 Install the Trolley

Assembly Section: Pages 6 - 7

Rail/Power Unit Bracket Lock Nuts 1/4"-20

1/4" - 20 Lock Nut 1/4" - 20 x 5/8" Hex Screw

Trolley · Power Unit Sprocket

Page 7 of the Liftmaster 2000SDR user manual — 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS
Page 7 · click to enlarge
Page 7

ASSEMBLY STEP 3

Attach the Rail Brackets

  • Align rail brackets to end of rail assembly, as shown.
  • Insert two 1/4"-20 x 5/8" hex screws and lock nuts. Tighten securely with a 7/16" socket.

Hardware Shown Actual Size

1/4" - 20 Lock Nut 1/4" - 20 x 5/8" Hex Screw

You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section:

IMPORTANT INSTALLATION INSTRUCTIONS

WARNING WARNING

To reduce the risk of severe injury or death to persons:

1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

2. Install only on a properly balanced and lubricated garage door. An improperly balanced door may not reverse and could result in severe injury or death. Repairs to cables, spring assemblies and other hardware must be made by a professional service person before installing opener.
3. Disable all locks and remove all ropes connected to the garage door before installing the opener. Ropes connected to a garage door can cause entanglement and death.
4. If possible, install door opener 7 feet or more above floor with the manual release handle mounted 6 feet above the floor.
5. Do not connect the opener to power source until instructed to do so.
6. Locate the Door Control within sight of the door at a minimum height of 5 feet where small children cannot reach and away from all moving parts of the door.
7. Install the User Safety Instruction Label on the wall adjacent to the control button and the Maintenance Instruction Label in a prominent location on the inside of the garage door.
8. Upon completion of the installation, the door must reverse when it comes in contact with a one-inch high object or a 2x4 laid flat on the floor.
9. Do not wear watches, rings or loose clothing while installing or servicing an opener. Jewelry or loose clothing can be caught in the mechanism of the garage door or the opener.
Show 4 more labels / short text on this page
1/4"-20 Lock Nuts · Rail Brackets · 1/4"-20x5/8 Hex Screws · Rail
Page 8 of the Liftmaster 2000SDR user manual — SECTIONAL Door or ONE PIECE Door with Track
Page 8 · click to enlarge
Page 8

Proceed to Step 2, page 10.

  • Open your door to the highest point of travel as shown. Draw an intersecting horizontal line on the header wall 3" above the high point. This height will provide travel clearance for the top edge of the door.

Installation Step 1 Determine Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door.

Vertical Guideline Header Wall 2x4 Structural Supports

SECTIONAL Door or ONE PIECE Door with Track

Installation Section: Pages 8 – 23

Liftmaster 2000SDR — SECTIONAL Door or ONE PIECE Door with Track diagram (page 8)
Fig. 5 · SECTIONAL Door or ONE PIECE Door with Track

Sectional door with curved track

The garage door springs, cables, pulleys, brackets and their hardware are under extreme tension. Do not attempt to loosen, move or adjust them yourself. Serious personal injury or death could result. Call for professional garage door service.

If the header bracket is not rigidly fastened to a structural support on the header wall or ceiling, the safety reverse system may not work properly (see page 26). The door might not reverse when required, and could cause serious injury or death.

  • Close the door and mark the inside vertical centerline of the garage door.
  • Extend the line onto the header wall above the door. Remember, you can fasten the header bracket within 2 feet of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (refer to page 10) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2".) If you need to install the header bracket on a 2x4 (on wall or ceiling), use lag screws (not supplied) to securely fasten the 2x4 to structural supports as shown here and on page 9.
Liftmaster 2000SDR — SECTIONAL Door or ONE PIECE Door with Track diagram (page 8)
Fig. 6 · SECTIONAL Door or ONE PIECE Door with Track

One-piece door with horizontal track

Vertical Guideline · Finished Ceiling

Page 9 of the Liftmaster 2000SDR user manual — OPTIONAL CEILING MOUNT
Page 9 · click to enlarge
Page 9

ONE-PIECE Door Without Track

Read the Safety Instructions on page 8. They also apply to doors without tracks.

  • Close the door and mark the inside vertical centerline of your garage door. Extend the line onto the header wall above door. If headroom clearance is minimal, you can install the header bracket on the ceiling. See page 10.
  • If you need to install the header bracket on a 2x4 (on wall or ceiling), use lag screws (not supplied) to securely fasten the 2x4 to structural supports as shown.

Vertical Centerline of Garage Door

OPTIONAL CEILING MOUNT

FOR HEADER BRACKET

pivot hardware One-piece door without track

One-piece door without track

  • Open your door to the highest point of travel as shown. Measure the distance from the top of the door to the floor. Subtract the actual height of the door. Add 8" to the remainder. (See Example).
  • Close the door and draw an intersecting horizontal line on the header wall at the determined height. If the total number of inches exceeds the height available in your garage, use the maximum height possible, or refer to page 10 for ceiling installation.

EXAMPLE Distance from top of door (at highest point of travel) to floor 92" Actual height of door -88" Remainder 4" Add +8" Bracket height on header wall =12" (Measure UP from top of CLOSED door.)

Proceed to Step 2, page 10.

Show 20 more labels / short text on this page
Unfinished · Header Wall · Ceiling · Vertical Centerline · Structural Supports · 2x4 Header Support · Header Wall · of Travel Header · Highest Point · Highest Point · Wall · of Travel · Door · Door · Distance · Distance · Jamb Hardware · Pivot · Floor Floor · jamb hardware
Page 10 of the Liftmaster 2000SDR user manual — CEILING MOUNT ONLY
Page 10 · click to enlarge
Page 10
  • Center the bracket on the vertical guideline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
  • Mark either set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.

Fastening the Header Bracket to the Wall

Install the Header Bracket

Installation Step 2

Liftmaster 2000SDR — Fastening the Header Bracket to the Wall diagram (page 10)
Fig. 7 · Fastening the Header Bracket to the Wall

Optional Wall Mounting Holes

CEILING MOUNT ONLY

UP

The nail hole is for positioning only. You must use lag screws to mount the header bracket.

Hardware Shown Actual Size

Lag Screw 5/16"-9 x 1-5/8"

Fastening the Header Bracket to the Ceiling

You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements.

  • Extend the vertical guideline onto the ceiling as shown.
  • Center the bracket on the vertical mark, no more than 6" from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
  • Mark holes designated for ceiling mount only. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.

The nail hole is for positioning only. You must use lag screws to mount the header bracket.

Liftmaster 2000SDR — Fastening the Header Bracket to the Ceiling diagram (page 10)
Fig. 8 · Fastening the Header Bracket to the Ceiling

CEILING MOUNT ONLY

UP

Show 4 more labels / short text on this page
2x4 Structural Support · Wall Mounting Holes · Lag Screws 5/16"x9x1-5/8" · Ceiling Mounting Holes
Page 11 of the Liftmaster 2000SDR user manual — Attach the Rail to the Header Bracket
Page 11 · click to enlarge
Page 11

Installation Step 3

Attach the Rail to the Header Bracket

  • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
  • Position the rail bracket against the header bracket.
  • Align the bracket holes and join with a clevis pin as shown.
  • Insert a ring fastener to secure.

Clevis Pin 5/16"x2-3/4 "

Hardware Shown Actual Size

Clevis Pin 5/16" x 2-3/4" Ring Fastener

Show 14 more labels / short text on this page
Header Wall · Header Bracket · Rail Bracket · Ring Fastener · Header Bracket · Rail · Rail Bracket · Rail · Garage · Door · Foam Packaging · Opener Carton or · Temporary · Support
Page 12 of the Liftmaster 2000SDR user manual — IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
Page 12 · click to enlarge
Page 12

The Protector System ®

IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR

The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. This is a required safety device and cannot be disabled.

Without a properly working safety reversing sensor, persons (particularly children) could be injured or killed by a closing garage door. Read and follow all instructions.

To protect small children, install the safety reversing sensor so that the beam will be no higher than 4"-6" above the garage floor.

When properly connected and aligned, the safety reversing sensor will detect an obstacle in the path of its electronic beam. The sending eye (with an orange indicator light) transmits an invisible light beam to the receiving eye (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener light will flash for 5 seconds. The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, between 4-6" above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens. The mounting brackets are designed to clip onto the garage door track without additional hardware.

Disconnect power to the garage door opener before installing the safety reversing sensor.

If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see Accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary. The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.

4-6" max. above floor

4-6" max. above floor

Facing the door from inside the garage

Show 4 more labels / short text on this page
Sensor Beam · Sensor Beam · Invisible Light Beam · Protection Area
Page 13 of the Liftmaster 2000SDR user manual — Installation Step 4 Install the Safety Reversing Sensor (Receiving and Sending Eyes)
Page 13 · click to enlarge
Page 13

Installation Step 4 Install the Safety Reversing Sensor (Receiving and Sending Eyes)

Installing the Brackets Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam from 4 – 6" above the floor.

Liftmaster 2000SDR — Installation Step 4 Install the Safety Reversing Sensor (Receiving and Sending Eyes) diagram (page 13)
Fig. 9 · Installation Step 4 Install the Safety Reversing Sen…

They may be installed in one of three ways, as follows.

Garage door track installation (preferred): • Slip the curved arms over the rounded edge of the door track. Snap into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown in Figure 1. If your door track will not support the bracket securely, wall installation is recommended.

  • Wall installation:
  • Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed.
  • If additional depth is needed, an extension bracket (see Accessories) or wood blocks can be used.
  • Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, from 4–6" above the floor.
  • Attach brackets to wall with lag screws (not provided).
  • If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared.
  • Floor installation:
  • Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be 4-6" above the floor.
  • Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared.
  • Fasten to the floor with concrete anchors as shown.
Page 14 of the Liftmaster 2000SDR user manual — Installation Step 4 (Continued) Install the Safety Reversing Sensor
Page 14 · click to enlarge
Page 14

Installation Step 4 (Continued) Install the Safety Reversing Sensor

  • Mounting and Wiring the Safety Sensors
  • Slide a 1/4"-20x1/2" carriage bolt head into the slot on both sensors. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension. See Figure 4.
  • Finger tighten the wing nuts.
Liftmaster 2000SDR — Installation Step 4 (Continued) Install the Safety Reversing Sensor diagram (page 14)
Fig. 10 · Installation Step 4 (Continued) Install the Safety R…

Recommended Wire Routing 1. Using insulated staples, run the wires from both sensors to the rail at the door header (see Figure 5). 2. Cross and twist the two wires where they meet the rail (see inset A). Run the wires inside the channels at the top of the rail, along each side, to the power unit and pull taut (see inset B). Do not use the lower (trolley) channels. NOTE: If your access door is near the garage door, you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires. Use one rail channel for the door control wire and the other channel for both sensor wires. If you choose this option, follow instructions 1-3 on page 21 now. 3. Thread the wires through the tabs on top of the drive shaft cover. 4. With your screwdriver tip, tuck the wires snugly into the rail channels. You will complete the wiring in Installation Step 7.

Liftmaster 2000SDR — Installation Step 4 (Continued) Install the Safety Reversing Sensor diagram (page 14)
Fig. 11 · Installation Step 4 (Continued) Install the Safety R…
Liftmaster 2000SDR — Installation Step 4 (Continued) Install the Safety Reversing Sensor diagram (page 14)
Fig. 12 · Installation Step 4 (Continued) Install the Safety R…
1. Run wires from sensors to end of rail at the door header. Cross & twist here to help contain wires in channels on top of rail.
2. Run wires along channels to power unit and pull taut.
3. Thread wires through tabs on top of Drive Shaft Cover.
4. With screwdriver blade, tuck wires snugly into channels.
Page 15 of the Liftmaster 2000SDR user manual — CAUTION
Page 15 · click to enlarge
Page 15
  • With the door fully open and parallel to the floor, measure the distance from the floor to the top of the door.
  • Using a stepladder as a support, raise the opener to the same distance as the door from the floor (it will be at a slight angle as shown).
  • The top of the door should be level with the top of the opener. Do not position the opener more than 3" above this point.
  • A 2x4 laid flat is convenient for setting an ideal doorto-rail distance.
  • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
  • Open the door all the way and place a 2x4 laid flat on the top section beneath the rail. If the top panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect the inner and outer sections. The trolley can remain disconnected until Step 12 is completed.

Installation Step 5 Position the Opener Follow instructions which apply to your door type as illustrated.

ONE-PIECE Door without Track

SECTIONAL Door or ONE-PIECE Door with Track

Liftmaster 2000SDR — ONE-PIECE Door without Track diagram (page 15)
Fig. 13 · ONE-PIECE Door without Track
Liftmaster 2000SDR — ONE-PIECE Door without Track diagram (page 15)
Fig. 14 · ONE-PIECE Door without Track

To prevent damage to steel, alumin um, fiberglass or glass panel doors, do not rest the opener on the door without using a 2x4.

CAUTION

Trolley Release Arm · Trolley · Rail 2x4

Page 16 of the Liftmaster 2000SDR user manual — CONTROL
Page 16 · click to enlarge
Page 16

Installation Step 6 Hang the Opener

The opener could fall and injure someone if it is not properly secured. Fasten the opener securely to structural supports of the garage.

  • Two representative installations are shown. Yours may be different. Hanging brackets should be angled, Figure 1, to provide rigid support. On finished ceilings, Figure 2, attach a sturdy metal bracket to structural supports before installing the opener. The bracket and fastening hardware are not supplied.
  • Measure the distance from each side of the opener to the structural support.
  • Cut both pieces of the hanging bracket to required lengths.
  • Drill 3/16" pilot holes in the structural supports.
  • Attach one end of each bracket to a support with 5/16" - 18x1-7/8" lag screws.
  • Fasten the opener to the hanging brackets with 5/16" - 18x7/8" screws, lock washers and nuts.
  • Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door).
  • Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket.

Lag Screws 5/16"- 18x1-7/8"

CONTROL

5/16"-18x7/8" Hex Screws 5/16" Lock Washers 5/16"-18 Nuts

CENTER

Preferred Range of Bracket Placement

Hardware Shown Actual Size

— FINISHED CEILING —

Lag Screw 5/16"-18 x 1-7/8"

(Not Supplied) 5/16"-18x7/8" Screw 5/16" Lock Washer 5/16"-18 Nut

Hex Screw 5/16"- 18 x 7/8" Nut 5/16" - 18 Lockwasher 5/16"

5/16"-18x7/8" Screw 5/16" Lock Washer 5/16"-18 Nut

CONTROL

CENTER

Preferred Range of Bracket Placement

Show 6 more labels / short text on this page
Structural · Supports · Measure Distance · Bracket (Not Supplied) · Hidden Support · Lag Screws 5/16"-18x1-7/8"
Page 17 of the Liftmaster 2000SDR user manual — OPENER TERMINAL SCREWS
Page 17 · click to enlarge
Page 17

Installation Step 7 Install the Door Control and Connect all Wiring

WARNING WARNING

DO NOT CONNECT TO LIVE ELECTRICAL WIRING. CONNECT ONLY TO 24 VOLT LOW VOLTAGE WIRES. CONNECTION TO LIVE WIRES OR HIGHER VOLTAGE MAY CAUSE SERIOUS INJURY FROM SHOCK, BURN OR ELECTROCUTION. Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death. Do not allow children to operate the push button or the remote control transmitter. A moving garage door could injure someone under it. Activate the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.

  • Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware. The door control is typically attached directly to the wall. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), the multi-function door control can be mounted to a standard single gang box. 1. Strip 1/4" of insulation from one end of the bell wire and connect it to the two screw terminals on the back of the door control by color: white to 2 and white/red to 1. (Fig. 1) 2. Lighted door control: Fasten to wall with 6ABx1-1/2" selftapping screws. Multi-function: Remove the white cover by gently pushing both thumbs against upper corners of cover on the back side of the door control (Fig. 2). Fasten with 6ABx1-1/4" selftapping screws (standard installation) or 6-32x1" machine screws (pre-wired installation) as follows: (Fig. 3)
  • Install bottom screw, allowing 1/8" to protrude from the wall.
  • Position bottom of door control over screw head and adjust for snug fit.
  • Install top screw with care to avoid cracking plastic housing. Do not overtighten.
  • Replace cover by inserting bottom tabs and snapping into place. To remove cover after mounting, gently pry at top with paper clip or small flat head screwdriver. NOTE: After installation, a green indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct). 3. Standard installation only: Run bell wire up wall and across ceiling to opener. Use insulated staples to secure wire in several places. Be careful not to pierce the wire with a staple, creating a short. If your access door is near the garage door, you may run this wire with the Safety Reversing Sensor wires along the top of the rail. See page 14. 4. Remove Control Center door on right panel of opener to access the terminal screws. 5. Thread all wires through the opening at the base of the drive shaft cover (Fig. 4). 6. Insert the remaining wire through the hole in the power unit and strip 1/4" of insulation from each set of wires. 7. Connect door control wire to the opener terminal screws: white to 2 and white/red to 1. 8. Connect sensor wires to the opener terminal screws: white to 2 and white/black to 3. 9. Attach the User Safety Instruction label to the wall near the door control, and the Maintenance Instruction label in a prominent location on the inside of the garage door. Page 28 explains how to operate the opener using the door control.

Do NOT connect the power and operate the opener at this time. See Step 9 on page 18.

Outside Keylock connections (see Accessories) To opener terminal screws: white to 2; white/red to 1

Figure 1 Figure 2

WHT

RED WHT

RED WHT

RED

REMOVE COVER

STANDARD INSTALLATION

PRE-WIRED INSTALLATION

LOCK

LIGHT To Replace, Insert Bottom Tabs First

LOCK

24 Volt 2-Conductor Bell Wire

LIGHT

To Replace, Insert Bottom Tabs First

WIRING TO CONTROL CENTER

1. INSERT WIRES THROUGH OPENING IN DRIVE SHAFT

COVER

2. PUSH WIRING THROUGH HOLE IN

CHASSIS (ABOVE CONTROL

Hardware Shown Actual Size

CENTER) AND

CONNECT TO OPENER TERMINAL

Sensor Connections Door Control Connections

SCREWS 6ABx1-1/2" Screw Lighted Door Control Button

6AB x 1-1/4" Screw Multi-function (std installation)

6-32 x 1" Screw Multi-function (pre-wired)

OPENER TERMINAL SCREWS

Show 16 more labels / short text on this page
Terminal · Screws · Lighted Door Control · Multi-Function · Door Control · To Sensors · To Door Control · Terminal · Screws · Control · Center · (dotted line) · Insulated · Staples · Dry Wall Anchors · (In Control Center)
Page 18 of the Liftmaster 2000SDR user manual — Installation Step 9 Complete Safety Reversing Sensor Installation
Page 18 · click to enlarge
Page 18

Installation Step 8 Electrical Requirements

Liftmaster 2000SDR — Installation Step 8 Electrical Requirements diagram (page 18)
Fig. 15 · Installation Step 8 Electrical Requirements

To prevent electrocution or fire, installation and wiring must be in compliance with local electrical and building codes.

To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn't fit into the outlet you have, contact a qualified electrician to install the proper outlet.

Do NOT use an extension cord, 2-wire adapter, or change the plug in any way to make it fit your outlet.

To avoid installation difficulties, do not run the opener until Step 9 below.

Liftmaster 2000SDR — Installation Step 8 Electrical Requirements diagram (page 18)
Fig. 16 · Installation Step 8 Electrical Requirements

If permanent wiring is required by your local code, refer to the following procedure: Right Wrong

To prevent electrocution, remove power from the

garage door opener and from the circuit you plan to use for the permanent connection.

Liftmaster 2000SDR — Installation Step 8 Electrical Requirements diagram (page 18)
Fig. 17 · Installation Step 8 Electrical Requirements
  • To make a permanent connection through the 7/8" diam. hole in the top of the opener (according to local code):
  • Remove the opener cover screws and set the cover aside.
  • Remove the attached 3-prong cord.
  • Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
  • Reinstall the cover.

Installation Step 9 Complete Safety Reversing Sensor Installation

  • Trouble Shooting 1. If the sending eye indicator light does not glow steadily after installation, check for:
  • Electric power to the opener.
  • A short in the white or white/black wires. These can occur under staples or at screw terminal connections.
  • Incorrect wiring between sensors and opener.
  • A broken wire. 2. If the sending eye indicator light glows steadily but the receiving eye indicator light doesn't:
  • Check alignment.
  • Check for an open wire to the receiving eye. 3. If the receiving eye indicator light is dim, realign either sensor. NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will flash 10 times. (If bulbs are not installed, 10 clicks are audible.) See page 12.
  • Aligning the Safety Sensors
  • Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. The sending eye orange indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.
  • Loosen the sending eye wing nut and re-adjust, aiming directly at the receiving eye. Lock in place.
  • Loosen the receiving eye wing nut and adjust sensor vertically and/or horizontally until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.
Page 19 of the Liftmaster 2000SDR user manual — Installation Step 10 Install the Lights and Lens
Page 19 · click to enlarge
Page 19

Installation Step 10 Install the Lights and Lens

Liftmaster 2000SDR — Installation Step 10 Install the Lights and Lens diagram (page 19)
Fig. 18 · Installation Step 10 Install the Lights and Lens
  • Install a 100 watt maximum light bulb in each socket. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.
  • Insert bottom lens tabs into slots on chassis and tilt towards chassis to engage top tabs, then drop down gently into place. (See illustration.)
  • To remove, lift lens up and gently tilt slightly outward and down, then pull out to clear bulbs. Use care to avoid snapping off bottom lens tabs.
  • If the bulbs burn out prematurely, replace with standard neck Garage Door Opener bulbs. (Fluorescent bulbs are not recommended because of possible interference with receiver/transmitter signals.)

Installation Step 11 Attach the Manual Release Rope and Handle Do not use the red handle to pull the door open or closed. The rope knot could become untied and you could fall. Use the manual release only to disengage the trolley and, if possible, only when the door is closed.

Liftmaster 2000SDR — Installation Step 10 Install the Lights and Lens diagram (page 19)
Fig. 19 · Installation Step 10 Install the Lights and Lens
Liftmaster 2000SDR — Installation Step 10 Install the Lights and Lens diagram (page 19)
Fig. 20 · Installation Step 10 Install the Lights and Lens

Garage doors are heavy. If the door is open when the handle is pulled, the door could close inadvertently if it is not properly balanced. Serious injury may result to persons under the door. Make sure the doorway is clear of persons and obstructions before pulling handle when door is open.

Liftmaster 2000SDR — Installation Step 10 Install the Lights and Lens diagram (page 19)
Fig. 21 · Installation Step 10 Install the Lights and Lens
  • Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot at least 1" from the end of the rope to prevent slipping.
  • Thread the other end of the rope through the hole in the release arm of the outer trolley.
  • Adjust rope length so the handle is 6 feet above the floor. Secure with an overhand knot . If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
Page 20 of the Liftmaster 2000SDR user manual — UP
Page 20 · click to enlarge
Page 20

Installation Step 12 Fasten Door Bracket

CAUTION CAUTION

Follow instructions which apply to your door type as illustrated below or on page 21.

To prevent damage to steel, aluminum, fiberglass or glass panel doors, always reinforce the inside of the door both vertically and horizontally with an angle iron.

A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should cover the height of the top panel. The illustration shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit.

SECTIONAL Door Installation Procedure

Horizontal and vertical reinforcement is needed for lightweight garage doors

(fiberglass, aluminum, steel, doors with glass panel, etc).

UP

of Door or Reinforcement Board

UP

  • Center the door bracket on the previously marked vertical guideline used for the header bracket installation. Note the correct UP placement, as stamped inside the bracket.
  • Position the bracket on the face of the door within the following limits: A) The top edge of the bracket 2-4" below the top edge

Hardware Shown Actual Size

of the door. B) The top edge of the bracket directly below any

structural support across the top of the door. • Mark and drill 5/16" left and right fastening holes. Secure the bracket as shown in Figure 1 if there is vertical reinforcement. If your installation doesn't require vertical reinforcement but does need top and bottom fastening holes for the door bracket, fasten as shown in Figure 2.

Nut 5/16" - 18 Lockwasher 5/16"

Carriage Bolt 5/16"-18 x 2-1/2"

Show 12 more labels / short text on this page
Header Bracket · Vertical Reinforcement · Vertical Guideline · Door Bracket Location · Carriage Bolt 5/16"-18x2-1/2" · Vertical Guideline · Door Bracket · Lock Washer · 5/16" · Nut 5/16"-18 · Inside Edge · Door Bracket
Page 21 of the Liftmaster 2000SDR user manual — One-Piece Door
Page 21 · click to enlarge
Page 21
Liftmaster 2000SDR — One-Piece Door diagram (page 21)
Fig. 22 · One-Piece Door

Please read and comply with the warnings and reinforcement instructions on page 20. They apply to one-piece doors also.

For a door with no exposed framing or for the optional installation, use 5/16"x1-1/2" lag screws (not provided) to fasten door bracket.

  • Center the bracket on the top of the door, in line with the header bracket as shown. Mark holes.
  • Drill 5/16" pilot holes and fasten the door bracket with hardware supplied. If the door has no exposed framing, drill 3/16" pilot holes and fasten the bracket with 5/16"x1-1/2" lag screws (not provided) to the top of the door. The door bracket may be installed on the top edge of the door if required for your installation. (Refer to the dotted line optional placement drawing.) Drill 3/16" pilot holes and substitute 5/16"x1-1/2" lag screws (not provided) to fasten the bracket to the door.
Liftmaster 2000SDR — One-Piece Door diagram (page 21)
Fig. 23 · One-Piece Door
Page 22 of the Liftmaster 2000SDR user manual — Hardware Shown Actual Size Hole Alignment Alternative
Page 22 · click to enlarge
Page 22
Liftmaster 2000SDR — Connect Door Arm to Trolley diagram (page 22)
Fig. 24 · Connect Door Arm to Trolley
  • Figure 3:
  • If holes in curved arm are above holes in straight arm, disconnect straight arm. Cut about 6" from the solid end. Reconnect to trolley with cut end down as shown.
  • Bring arm sections together.
  • Find two pairs of holes that line up and join with screws, lock washers and nuts.
Liftmaster 2000SDR — Connect Door Arm to Trolley diagram (page 22)
Fig. 25 · Connect Door Arm to Trolley
  • Figure 1:
  • Fasten straight door arm section to outer trolley with the 5/16"x1" clevis pin. Secure the connection with a ring fastener.
  • Fasten curved section to the door bracket in the same way, using the 5/16"x1-1/4" clevis pin.

Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" as shown in Figures 1, 2 and 3.

Follow instructions which apply to your door type as illustrated below and on page 23.

Installation Step 13 Connect Door Arm to Trolley

Hardware Shown Actual Size Hole Alignment Alternative

SECTIONAL Doors Only

Proceed to Adjustment Step 1, page 24. Trolley will re-engage automatically when the opener is operated.

Liftmaster 2000SDR — Hardware Shown Actual Size Hole Alignment Alternative diagram (page 22)
Fig. 26 · Hardware Shown Actual Size Hole Alignment Alternativ…
Liftmaster 2000SDR — Hardware Shown Actual Size Hole Alignment Alternative diagram (page 22)
Fig. 27 · Hardware Shown Actual Size Hole Alignment Alternativ…

Figure 2: • Bring arm sections together. Find two pairs of holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity.

Hex Screw 5/16"-18x7/8" Clevis Pin 5/16"x1" (Trolley) Clevis Pin 5/16"x1-1/4" (Door Bracket)

Page 23 of the Liftmaster 2000SDR user manual — Adjustment Procedures for One-Piece Doors
Page 23 · click to enlarge
Page 23

All ONE-PIECE Doors

  • Assemble the Door Arm:
  • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap).
  • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
  • Secure with a ring fastener.

Nuts 5/16"-18 Lock Washers

Adjustment Procedures for One-Piece Doors

On one-piece doors, before connecting the door arm to the trolley the travel limits must be adjusted. Limit adjustment screws are located on the right side panel as shown on page 24. Follow adjustment procedures below.

Door Arm Connector Hole Door Arm Connector Hole

Door Open Door Door with Backward Slant

  • Open Door Adjustment: Decrease UP Travel Limit
  • Turn the UP limit adjustment screw counter-clockwise 5 1/2 turns.
  • Press the Door Control push bar or button. The trolley will travel to the fully open position.
  • Manually raise the door to the open position (parallel to the floor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 2" of trolley travel.
  • Closed Door Adjustment: Decrease DOWN Travel Limit
  • Turn the DOWN limit adjustment screw clockwise 5 complete turns.
  • Press the Door Control push bar or button. The trolley will travel to the fully closed position.
  • Manually close the door and lift the door arm to the trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 2" of trolley travel.
  • Connect the Door Arm to the Trolley:
  • Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin. It may be necessary to lift the door slightly to make the connection.
  • Secure with a ring fastener.
  • Run the opener through a complete travel cycle. If the door has a slight "backward" slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the floor.
Show 15 more labels / short text on this page
Ring Fastener · Door Bracket · 5/16" · Clevis Pin 5/16"x1-1/4" · Straight · Arm · Screws 5/16"-18x7/8 · Curved Door Arm · Fully Closed · Trolley · Fully Open · Trolley · Door Arm · Closed · Door Arm
Page 24 of the Liftmaster 2000SDR user manual — LIMIT ADJUSTMENT
Page 24 · click to enlarge
Page 24

Adjustment Section: Pages 24 – 26

Adjustment Step 1

Adjust the UP and DOWN Limits Do not make any limit adjustments until the safety reversing sensors are completely installed.

Improper adjustment of the travel limits will interfere with the proper operation of the safety reverse system. The door might not reverse properly when required and could seriously injure or kill someone under it. Test the safety reverse system monthly, and following all adjustments to the travel limits. See page 26.

  • Limit adjustment settings regulate the points at which the door will stop when moving up or down. The door will stop in the up direction if anything interferes with door travel. The door will reverse in the down direction if anything interferes with the door travel (including binding or unbalanced doors). To operate the opener, press the Door Control push bar or button. Run the opener through a complete travel cycle.
  • Does the door open and close completely?
  • Does the door stay closed and not reverse unintentionally when fully closed? If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (see page 26).

Adjustment procedures are outlined below. Run the opener through a complete travel cycle after each adjustment. Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again. Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments.

LIMIT ADJUSTMENT

LABEL

How and When to Adjust the Limits

If the door does not open completely but opens at least five feet: Increase up travel. Turn the UP limit adjustment screw clockwise. One turn equals 2" of travel. If door does not open at least 5 feet: Adjust the UP (open) force as explained in Adjustment Step 2.

If the opener reverses in fully closed position: Decrease down travel. Turn the DOWN limit adjustment screw clockwise. One turn equals 2" of travel.

If the door reverses when closing and there is no visible interference to travel cycle: If the opener lights are flashing, the Safety Reversing Sensors are either not installed, misaligned, or obstructed. See Troubleshooting, page 18. Test the door for binding: Pull the manual release handle. Manually open and close the door. If the door is binding, call for garage door service. If the door is not binding or unbalanced, adjust the DOWN (close) force. See Adjustment Step 2.

If the door does not close completely: Increase down travel. Turn the DOWN limit adjustment screw counterclockwise. One turn equals 2" of travel. If door still won't close completely, try lengthening the door arm. (Page 22.) If you have adjusted the door arm to the maximum length and the door still will not close completely, lower the header bracket. See Installation Step 1, pages 8/9.

Show 11 more labels / short text on this page
+ · + · Kg Kg · Travel Limit · Adjustment · Right Side Panel · Screws · + · Adjust UP Travel · + · Adjust DOWN Travel
Page 25 of the Liftmaster 2000SDR user manual — How and When to Adjust the Forces
Page 25 · click to enlarge
Page 25

Adjustment Step 2

Adjust the Force

Too much force on the door will interfere with the proper operation of the safety reverse system. The door might not reverse properly when required and could seriously injure or kill someone under it. Do not increase the force beyond the minimum amount required to close the door. Do not use the force adjustments to compensate for a binding or sticking garage door. Test the safety reverse system monthly, and following all adjustments to force levels. See page 26.

Force adjustment controls are located on the right panel of the opener. Force adjustment settings regulate the amount of power required to open and close the door. The door will stop in the up direction if anything interferes with its travel. The door will reverse in the down direction if anything interferes with its travel (including binding or unbalanced doors). If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed. The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver.

How and When to Adjust the Forces

Test the DOWN (close) force Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse. Reversal halfway through down travel does not guarantee reversal on a one-inch obstruction. See page 26. If the door is hard to hold or doesn't reverse, decrease the DOWN (close) force by turning the control counterclockwise. Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.

If the door doesn't open at least 5 feet: Increase UP (Open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.

If the door reverses during the down (close) cycle and the opener lights aren't flashing: Increase DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the force beyond the minimum amount required to close the door.

Test the UP (open) force Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn't stop, decrease UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily. After each adjustment, run the opener through a complete travel cycle.

Show 9 more labels / short text on this page
+ · Kg Kg · + · Right Side · Force Adjustment · Panel · Controls · Kg Kg · Force Adjustment Label
Page 26 of the Liftmaster 2000SDR user manual — Adjustment Step 4 Test the Safety Reverse System
Page 26 · click to enlarge
Page 26

Adjustment Step 3 Test The Protector System ®

Without a properly working safety reversing sensor, persons (particularly children) could be seriously injured or killed if trapped by a closing garage door. Repeat this test once a month.

  • Press the remote control push button to open the door.
  • Place the opener carton in the path of the door.
  • Press the remote control push button to close the door. The door will not move more than an inch, and the opener light will flash for 5 seconds. Professional service is required if the opener closes the door when the safety reversing sensor is obstructed. The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). The garage door can be closed by pressing and holding the Door Control push bar or button until down travel is completed.

Safety Reversing Sensor Safety Reversing Sensor

Adjustment Step 4 Test the Safety Reverse System

Failure to test and adjust the safety reverse system may result in serious injury or death to persons trapped by a closing garage door. Repeat this test once a month and adjust as needed.

  • Test
  • Place a one-inch board (or a 2x4 laid flat) on the floor, centered under the garage door.
  • Operate the door in the down direction. The door must reverse on striking the obstruction.
  • Adjustment If the door stops on the obstruction, it is not traveling far enough in the down direction.
  • Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn.
  • Repeat the test. On a sectional door, make sure limit adjustments do not force the door arm beyond a straight up and down position. See the illustration on page 22.
  • When the door reverses on the one-inch board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment. If the door will not reverse after repeated adjustment attempts, call for professional garage door service.

One-Inch board (or a 2x4 laid flat)

  • Important Safety Check Repeat Adjustment Steps 1-4 after:
  • Each adjustment of door arm length, force controls or limit controls.
  • Any repair to or adjustment of the garage door (including springs and hardware).
  • Any repair to or buckling of the garage floor.
  • Any repair to or adjustment of the opener.

1 Inch Obstruction

Page 27 of the Liftmaster 2000SDR user manual — FORCE CONTROLS
Page 27 · click to enlarge
Page 27
Liftmaster 2000SDR — IMPORTANT SAFETY INSTRUCTIONS diagram (page 27)
Fig. 28

Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 24 and 25 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. Repeat the safety reverse test (page 26) after any adjustment of limits or force.

Once a Month Manually operate door. If it is unbalanced or binding, call for professional garage door service. Check to be sure door opens & closes fully. Adjust limits and/or force if necessary. (See pages 24 & 25.)

Force and Limit Adjustment Controls

1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Do not permit children either to operate or to play with the opener. Keep remote control in a location inaccessible to children. 3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4. Check safety reversal system monthly. See page 26. The garage door MUST reverse on contact with a one inch object (or a 2x4 board laid flat) placed on the floor. If an adjustment is made to one of the controls (either force or limits of travel), the other control may need to be adjusted also, and the safety reversal system must be checked. Failure to properly adjust the opener may result in severe injury or death. 5. If possible, use the manual release only when the door is in a closed position. Caution should be taken whenever the disconnect cord is actuated with the door open. Weak or broken springs may cause the door to fall rapidly, causing injury or death to persons. 6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3. An improperly balanced door may not reverse when required, and could result in severe injury or death. Repairs to cables, spring assemblies and other hardware must be made by a professional garage door person. 7. Disconnect the electric power to the garage door opener before making any repairs or removing the covers. SAVE THESE INSTRUCTIONS

To reduce the risk of severe injury or death to persons:

FORCE CONTROLS

IMPORTANT SAFETY INSTRUCTIONS

WARNING WARNING

Care of Your Opener

LIMIT CONTROLS

Once a Year Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.

Repeat the safety reverse test. Make any necessary adjustments (See page 26).

The Transmitter Battery The yellow test light will glow and the opener will operate when the remote control is activated, as long as there is adequate battery power. If the power indicator light is dim or off, replace the battery. Also check the test light if transmission range decreases. The 12 volt battery should produce power for at least a year. Dispose of your old battery properly.

The Remote Control Transmitter The opener must learn the code of any new remote control. Page 29 explains how to program your receiver and how to erase all codes if required. Self service of your receiver and remote controls is not recommended. If service is needed, call the toll-free number listed on the back page.

Kg Kg · + · +

Page 28 of the Liftmaster 2000SDR user manual — NOTICE
Page 28 · click to enlarge
Page 28

Operation of Your Opener

  • Activate the opener with any of the following:
  • The Remote Control Transmitter. Hold push button down until the door starts to move.
  • The Door Control. Hold push bar or button down until the door starts to move.
  • The Outside Keylock or Keyless Entry. (See Accessories) When the opener is activated with the safety reversing sensor installed and correctly aligned: 1. If open, the door will close. If closed, it will open. 2. If closing, the door will reverse. 3. If opening, the door will stop (allowing space for entry and exit of pets and for fresh air). 4. If the door has been stopped in a partially open position, it will close. 5. If obstructed while closing, the door will reverse. 6. If obstructed while opening, the door will stop. 7. The garage door will reverse in the closing cycle, and the opener lights will blink for 5 seconds, when the invisible beam is broken. If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle. If the sensor is not installed, or is not aligned correctly, the door won't close from any remote transmitter. You can close the door with the Door Control, the Outside Keylock, or Keyless Entry, however, if you activate them until down travel is complete . If you release them too soon, the door will reverse. Opener Lights will turn on under the following conditions: When the opener is initially plugged in; when the power is interrupted; when the opener is activated. It will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the Multi-Function Door Control is activated. Bulb size is 100 watts maximum. Lights will also turn on when someone walks through the open garage door. With a Multi-Function Door Control, this feature may be turned off as follows: With the opener lights off, press and hold the light button for 10 seconds, until the light goes on and off again. To restore this feature, start with the opener lights on, then press and hold the light button for 10 seconds.

Weak or broken springs could allow an open door to fall (either rapidly or unexpectedly), resulting in serious injury, death or property damage. If possible, use the manual release rope and handle only when the door is fully closed.

To open the door manually: The door should be fully closed if possible. Pull down on the manual release handle (so that the trolley release arm snaps into a vertical position) and lift the door manually. The lockout feature prevents the trolley from reconnecting auto- matically, and the door can be raised and lowered manually as often as necessary.

NOTICE

Lockout position (Manual disconnect)

To reengage the trolley: Pull the manual release handle toward the opener at a 45 degree angle so that the trolley release arm is horizontal. The trolley will reconnect on the next UP or DOWN operation, either manually or by pressing the Door Control push bar or button.

Handle (Pull at 45° angle)

NOTICE

Operation of the Door Controls: See additional programming features, next page.

Lighted Door Control Button: Press to open or close the door. Lighted Push Bar – Door Control Panel: Press the white square to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening. Light Feature – Door Control Panel: Press the Light button to turn the opener light on or off. If you turn it on and then activate the opener, the light will remain on for 4- 1/2 minutes. Press again to turn it off sooner. The Light button will not control the opener lights when the door is in motion. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes.

Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3- 1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes. Lock Feature – Door Control Panel: Designed to prevent operation of the door from portable remote controls. However, the door will open and close from the Door Control push bar, the Outside Keylock and the Keyless Entry Accessories.

To Activate: Press and hold the Lock button for 2 seconds. The push bar light will flash as long as the Lock feature is on. To turn off: Press and hold the Lock button again for 2 seconds. The push bar light will stop flashing. The Lock feature will also turn off whenever the “Smart” button on the opener panel is activated.

Show 8 more labels / short text on this page
Trolley · Trolley ReleaseArm · (in Manual Disconnect · Position) · Trolley · Trolley Release Arm · Manual Release · To reconnect
Page 29 of the Liftmaster 2000SDR user manual — Receiver & Remote Control Programming
Page 29 · click to enlarge
Page 29

To Control the Opener Lights With Security Plus transmitters, a remote push button can be programmed to operate the opener lights without opening the door. 1. With the door closed, press and hold the remote button that you want to control the light. 2. Press and hold the Light button on the door control. 3. Press and hold the Lock button on the door control. 4. After the opener lights flash, release all buttons. Test by pressing the remote push button. The opener lights should turn on or off but the door should not move. 29

To Erase All Remote Control Codes Press and hold the "Smart" button on the opener panel until the indicator light turns off (about 6 seconds). All transmitter codes are now erased. Then follow the steps above to re-program each remote control.

Adding a remote can also be done from the door control, as follows: 1. With the door closed, press and hold a remote push button. 2. Press and hold the Light button on the door control. 3. Press and hold the door control push bar. 4. After the opener lights flash, release all buttons. Test by pressing the remote push button.

To Add a Remote Control 1. Press and hold the selected remote control push button. See Figure 1. 2. Press and release the "Smart" (learn) button on the right side panel of the opener. See Figure 2. The indicator light on the panel will begin to blink and the opener lights will flash once. 3. Release the remote push button. Now the opener will operate when the remote control push button is pressed. Test by pressing the remote button to see that the door goes up and down.

  • “Security Plus” Your garage door opener receiver and remote control transmitter have been set at the factory to a matching code. The door will activate when you press the LARGE remote control push button. Your "Security Plus" opener will operate with:
  • several Security Plus remote controls (with yellow indicator lights) utilizing up to 8 functions. NOTE: Open/Close/Stop operation counts as 1 function.
  • one Keyless Entry System (with Security Plus logo) Follow the instructions below to program your opener to match any additional remotes you may purchase. See Accessories on page 34.

Receiver & Remote Control Programming

Model 67LM Security Plus Keyless Entry Follow instructions on page 34 (Accessories).

Open/Close/Stop Operation Your Security Plus remote control can be programmed to operate one door using all 3 buttons: the large button will only open the door, the middle button will only close the door, and the third button will stop the door’s movement. You may set up this feature as follows: 1. With the door closed, press and hold the large remote push button. 2. Press and hold the Lock button on the door control. 3. Press and hold the door control push bar. When the opener lights flash, release all buttons. Test by pressing the large (Open) button on the remote. The door should open. Press it again while the door is open and nothing should happen. Press the middle (Close) button and the door should close. Press the third (Stop) button while the door is moving and it should stop immediately.

Security Plus Remote Control

A moving garage door could injure or kill someone under it. Activate the opener only when you can see the door clearly, it is free of obstructions, and is properly adjusted.

Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death. Do not allow children to operate the door control(s) or remote control transmitter(s).

Yellow Battery Indicator Light Figure 1

Liftmaster 2000SDR — Receiver & Remote Control Programming diagram (page 29)
Fig. 29 · Receiver & Remote Control Programming

Select a push button

Code programming instructions are also located on the opener panel.

"Smart" (learn) Button · Indicator Light · Open Close Stop

Page 30 of the Liftmaster 2000SDR user manual — Situation Probable Cause & Solution
Page 30 · click to enlarge
Page 30

Having a Problem?

Situation Probable Cause & Solution

The opener doesn't operate from either the door control or the remote control:

1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.) 2. Have you disabled all door locks? Review installation instruction warnings on Page 7. 3. Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction. 4. The garage door spring may be broken. Have it replaced. 5. Repeated operation may have tripped the overload protector in the motor. Wait 15 minutes. Try again.

Opener operates from the remote control, but not from the door control:

1. Is the door control push bar lit? If not, Remove the bell wire from the opener terminal screws. Short the red and white terminals by touching both terminals at the same time with a piece of wire. If the opener runs, check for a faulty wire connection at the door control, a short under the staples, or a broken wire. 2. Are the wiring connections correct? Review Installation Step 7, page 17.

The door operates from the door control, but not from the remote control:

1. Is the door push bar flashing? If your model has the Lock feature, turn it off. 2. Your opener needs to re-learn a remote control code. Refer to instructions on the opener panel. 3. Program the receiver to match the remote control code. 4. Repeat the receiver programming procedure with all remote controls.

The remote control has short range:

1. Change the location of the remote control in your car. 2. Check to be sure the antenna on the right side panel of opener extends fully. 3. Some installations may have shorter range due to a metal door, foil backed insulation, or metal garage siding.

Opener noise is disturbing in living quarters of home:

If operational noise is a problem because of proximity of the opener to the living quarters, the Vibration Isolator Kit 41A3263 can be installed. This kit was designed to minimize vibration to the house and is easy to install.

The garage door opens and closes by itself:

1. Be sure that all remote control push buttons are off. 2. Remove the bell wire from the door control terminals and operate from the remote control only. If this solves the problem, the door control is faulty (replace), or there is an intermittent short on the wire between the door control and the opener. 3. Clear memory and reprogram all remote controls.
1. If the door has been working properly but now doesn't open all the way, increase the up force. See page 25. 2. Is something obstructing the door? Remove the obstruction or repair the door. 3. If door opens at least 5 feet, the travel limits may need to be increased. One turn equals 2 inches of travel. See page 24. Repeat the safety reverse test after the adjustment is complete.

The door doesn't open completely:

The door stops but doesn't close completely:

Review the travel limits adjustment procedures on page 24. Repeat the safety reverse test after any adjustment of door arm length, close force or down limit.

Page 31 of the Liftmaster 2000SDR user manual — Having a Problem? (continued)
Page 31 · click to enlarge
Page 31

The opener won't operate due to power failure:

The opener motor hums briefly, then won't work:

The door reverses for no apparent reason and opener lights blink for 5 seconds after reversing:

The door reverses for no apparent reason and opener lights don't blink:

The door opens but won't close:

Situation Probable Cause & Solution

The opener strains or maximum force is needed to operate door:

The opener lights… don't turn on: Replace the light bulb(s) (100 watts maximum). Use a standard neck garage door opener bulb if regular bulb burns out. don't turn off: Is the Light feature on? Turn it off.

1. Use the manual release handle to disconnect the trolley. The door can be opened and closed manually. When power is restored, press the Door Control push bar and trolley will automatically reconnect (unless trolley is in lockout position.) See page 28. 2. The Outside Quick Release accessory (for use on garages with no service door) disconnects the trolley from outside the garage in case of power failure.

1. Is something obstructing the door? Pull the manual release handle. Operate the door manually. If it is unbalanced or binding, call for professional garage door service. 2. Clear any ice or snow from the garage floor area where the door closes. 3. Review the force adjustment procedures on page 25. 4. If door reverses in the fully closed position, decrease the travel limits (page 24). Repeat the safety reverse test after adjustments to force or travel limits. The need for occasional adjustment of the force and limit settings is normal. Weather conditions in particular can affect door travel.

1. The garage door springs are broken. See above. 2. If the problem occurs on the first operation of the opener, door may be locked. Disable the door lock . Repeat the safety reverse test after the adjustment is complete.

The door may be out of balance or the springs are broken. Close the door and use the manual release handle to disconnect the trolley. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, disconnect the opener and call for professional garage door service. Do not increase the force to operate the opener.

Check the safety reversing sensor. Remove any obstruction or align the receiving eye. See page 18.

1. If the opener lights blink, check the safety reversing sensor. See page 18. 2. If the opener lights do not blink and it is a new installation, check the down force. See Adjustment Step 2, page 25. For an existing installation, see below. Repeat the safety reverse test after the adjustment is complete.

Having a Problem? (continued)

Page 32 of the Liftmaster 2000SDR user manual — NOTICE
Page 32 · click to enlarge
Page 32
Liftmaster 2000SDR — Repair Parts diagram (page 32)
Fig. 30 · Repair Parts

1 41A4795 Hardware bag (Includes sprocket coupling) 2 12B569-1 Left rail bracket 3 12B569-2 Right rail bracket 4 81C168 Rack 5 41C4677 Complete trolley assembly 6 1D4828-1 One-piece T-rail 7 41A4836 Drive sprocket kit 8 25A18 Sprocket coupling

Installation Parts

LOCK

LIGHT

KEY PART NO. NO. DESCRIPTION

1 41A5273-1 Multi-function door control panel 2 41A4166 Lighted door control button 3 29B137 Remote control visor clip 4 10A20 3V2032 Lithium battery 5 41A5056-1 Single-function remote control housing (no circuit board) 6 41A5056-3 3-Channel remote control housing (no circuit board) 7 217A238 2-Conductor bell wire - white & white/red 8 41A2828 Manual release rope & handle assy. 9 41A5047 Door bracket w/clevis pin & fastener 10 41A4353 Header bracket w/clevis pin & fastener 11 178B34 Straight door arm section 12 41A5034 Safety sensor kit (receiving and sending eyes with 3' 2-conductor bell wire attached) 13 12D584-1 Safety sensor brackets (2) 14 178B35 Curved door arm section NOT SHOWN 41A4116 Safety sensor hardware 41A4675-4 Opener installation hardware bag (See page 3) 114A2094 Owner's manual

NOTICE

CEILING MOUNT ONLY

UP

Page 33 of the Liftmaster 2000SDR user manual — 8b
Page 33 · click to enlarge
Page 33

Repair Parts

Power Unit Parts

(Down) Contact LIMIT SWITCH ASSY.

DN

UP

(Up) Contact Center Limit

8b

8d

8a

KEY PART NO. NO. DESCRIPTION

KEY PART NO. NO. DESCRIPTION

1 31D426 Drive shaft cover 2 41B4245 Line cord 3 30B363 Capacitor – 1/2 HP 30B387 Capacitor – 1/3 HP 4 12A373 Capacitor bracket 5 41A3150 Terminal block w/screws 6 41D4671 Limit switch assembly 7 12D554 Limit switch bracket 8 41D4759 Complete Motor Drive Assy., with 8a 144B41 22T Pulley 8b 144B42 28T Pulley 8c 20C14 Drive Belt 8d 158A69 Retainer Ring

9 41A4843 Interrupter cup 10 41A4837 Worm gear and retainer 11 41C4669 Wire harness assembly 12 41C4672 RPM sensor assembly 13 41D4674-10E Receiver logic board assembly 14 41D4839-6 Cover – LM 1/2 HP 41D4839-4 Cover – LM 1/3 HP 15 1C4840-4 Control Center access door 16 175C123 Light socket 17 108D47 Light lens

Show 9 more labels / short text on this page
w · ew Drive · Brown · Wire · Grey Wire · Drive Gear · Yellow · Contact · Wire
Page 34 of the Liftmaster 2000SDR user manual — To Add the Keyless Entry
Page 34 · click to enlarge
Page 34

Accessories Available For Your Opener

Model 1702LM SECURITY Single-Function Remote Control Includes visor clip.

Outside Quick Release Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.

Outside Keylock Operates the garage door automatically from outside when remote control is not handy.

SECURITY 2-Channel Remote Control Includes visor clip.

8 foot Complete Rail To allow an 8 foot door to open fully.

SECURITY 3-Channel Remote Control Includes visor clip.

Extension Brackets (Optional) For safety sensor installation onto the wall or floor.

SECURITY 4-Channel Remote Control Includes visor clip.

Passive Infrared Control Console Multi-function door control with motion sensor that automatically turns opener lights on for 5 minutes when it detects a person entering the garage. Sensor can be easily deactivated when desired.

SECURITY 3-Channel Mini Remote Control With key ring and Velco fastening strip.

LOCK LIGHT

SECURITY Keyless Entry Enables homeowner to operate garage door opener from outside by entering code on specially designed keyboard. Also can add a temporary pass code for visitors or service persons. This temporary code can be limited to a programmable number of hours or entries.

To Add the Keyless Entry

We recommend that you program your code before you install the Keyless Entry. You will not need assistance, and you can test the reception at the mounting location before installation.

You may also program the Keyless Entry from the Multi-Function Door Control, as follows: 1. With the door closed, enter the four digit code desired, then press and hold Enter. 2. Press and hold the light button on the door control. 3. Press and hold the door control push bar. 4. After the opener lights flash, release all buttons.

1. Choose a 4-digit code using numbers from 0 to 9 (a number can be used more than once, for example, 4, 0, 4, 1). 2. Press the four buttons for the code, then press and hold the Enter button. The indicator light on the door opener panel will blink. 3. Press and release the “Smart” (learn) button on the opener panel. After the opener lights flash, release the Enter button. Test by pressing the the code, then press Enter. The door should begin to move.

Show 10 more labels / short text on this page
Model 971LM · Model 59LM · Model 972LM · Model 88SD · Model 973LM · Model 97LM · Model 974LM · Model 970LM · Model 98LM · Model 976LM
Page 36 of the Liftmaster 2000SDR user manual — SERVICE INFORMATION TOLL FREE NUMBER:
Page 36 · click to enlarge
Page 36

LIFT-MASTER SERVICE

HOW TO ORDER

REPAIR PARTS

IS ON CALL

Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly.

OUR LARGE SERVICE ORGANIZATION

SPANS AMERICA

INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SIX DAYS A WEEK. SIMPLY DIAL OUR TOLL FREE NUMBER:

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

  • PART NUMBER
  • PART NAME
  • MODEL NUMBER

1-800-528-2817

HOURS: (Mountain Standard Time) 6:00 A.M. TO 6:00 P.M. Monday through Friday 7:00 A.M. TO 3:00 P.M. Saturday Closed Sunday

ADDRESS ORDERS TO:

THE CHAMBERLAIN GROUP, INC.

Pars and Service Department 2301 N. Forbes Boulevard, Suite 104 Tucson, Arizona 85745

For professional installation, parts and service, contact your local LIFT-MASTER/ CHAMBERLAIN dealer. Look for him in the Yellow Pages, or call our service number for a list of dealers in your area.

SERVICE INFORMATION TOLL FREE NUMBER:

1-800-528-2817

LIFT-MASTER GARAGE DOOR OPENER ONE-YEAR LIMITED WARRANTY

The Chamberlain Group, Inc., (“Seller”) warrants, to the first retail purchaser of this product, for the residence in which this product is originally installed, that it will be free from any defect in materials and/or workmanship for a period of one year from the date of purchase. The product must be used in complete accordance with Chamberlain’s instructions for installation, operation and care. The proper operation of this product is dependent on your compliance with the Owner’s Manual instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this warranty in its entirety. Please note that the safety reverse system, in order to operate properly with your garage door, must be adjusted and periodically tested in accordance with the Owner’s Manual. If, during the limited warranty period, it appears as though this product contains a defect which is covered by this limited warranty, call our toll free service number, before dismantling this product, at 1-800-528-2817. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call the toll free service number. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product that is returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option. THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLER’S PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, OR ANY ALTERNATIONS TO THIS PRODUCT), LABOR CHARGES FOR DISMANTLING OR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS, OR UNITS INSTALLED FOR NON-RESIDENTIAL USE. THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT AND HINGES. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH THE USE OF, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

LIMITED WARRANTY ON MOTOR Model 2000SDR: The motor is fully warranted for the lifetime of the product to the first-time purchaser. Model 1000SDR: The motor is warranted to be free from any defect in materials and/or workmanship for a period of 36 full months (3 years) from the date of purchase.

© 1999, The Chamberlain Group, Inc. 114A2094D All Rights Reserved Printed in Mexico

Ask about the Liftmaster 2000SDR

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Liftmaster 2000SDR

Be the first to ask — other owners or our team will answer.

Original document

Liftmaster 2000SDR manual PDF

36 pages·993 KB·Garage Door Opener·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…