EN
Laserliner logo
Official user manual

Laserliner PipeControlStation-Camera

92 pages·881 KB·Miscellaneous·PDF·EN
Laserliner PipeControlStation-Camera
Table of Contents 9 sections Length measure · CAMERA · PipeControlStation-Camera · Focal depth · … ShowHide
Page 1 of the Laserliner PipeControlStation-Camera user manual — CAMERA
Page 1 · click to enlarge
Page 1

Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !

Function / Application The PipeControlStation-Camera is a camera unit which can be connected to the VideoControl-Master base unit. The stand-up reel with a cable length of 30 m allows for inspections over great distances. Working with the base unit, colour video images are sent to the LCD for inspecting all places that are difÖ cult to access such as cavities, air shafts, in masonry or in heating and ventilation.

Laserliner PipeControlStation-Camera — Length measure diagram (page 1)
Fig. 1 · Length measure

Fastening screw for VideoControl-Master

Connection for control cable

Glass-Ö bre reinforced push rod, 30 m

Camera head with 12 high- power LEDs and SavetyLense

Length measure

The PipeControlStation-Camera features an integrated metre counter. The reeled off number of metres appears on the display of the VideoControl-Master (see image). Settings can be changed by means of the base unit. For more information, see: VideoControl-Master, Section 8.6 Length measure.

Laserliner PipeControlStation-Camera — Length measure diagram (page 1)
Fig. 2 · Length measure

2012/01/05 12:50:28

0 cm X 1.0

CAMERA

Show 6 more labels / short text on this page
Holder for VideoControl-Master · Locking screws · Flexible coil spring · Control cable · CameraProtector 28 mm · Integrated metre counter
Page 2 of the Laserliner PipeControlStation-Camera user manual — < 5 cm
Page 2 · click to enlarge
Page 2

PipeControlStation-Camera

Laserliner PipeControlStation-Camera — PipeControlStation-Camera diagram (page 2)
Fig. 3 · PipeControlStation-Camera

Menu Auto power off Input source Length measure Video output Delete all

ResetDelete measurement
UnitSwitch unit of measure (cm / inch)
Activate / deactivateSwitch metre counter on/off

Focal depth

The PipeControlStation-Camera delivers sharp images in a range between 5 and 60 cm from the camera head.

Laserliner PipeControlStation-Camera — Focal depth diagram (page 2)
Fig. 4 · Focal depth

Objects well beyond the focus range may appear blurred.

Laserliner PipeControlStation-Camera — Focal depth diagram (page 2)
Fig. 5 · Focal depth

< 5 cm

> 60 cm

Connection for control cable

Laserliner PipeControlStation-Camera — < 5 cm diagram (page 2)
Fig. 6 · < 5 cm

When screwing the control cable to the PipeControlStation-Camera and the VideoControl-Master base unit on top, ensure that the arrow on the connector plug points toward the groove of the respective device.

Laserliner PipeControlStation-Camera — < 5 cm diagram (page 2)
Fig. 7 · < 5 cm

The sensitive contact pins of the connector only fit into the socket in this position and can be damaged if not positioned correctly or used too forcefully. !

Page 3 of the Laserliner PipeControlStation-Camera user manual — The cable should not be rolled up by turning the reel. !
Page 3 · click to enlarge
Page 3

4 Roll up push rod

Laserliner PipeControlStation-Camera — The cable should not be rolled up by turning the reel. ! diagram (page 3)
Fig. 8 · The cable should not be rolled up by turning the ree…

To roll up the push rod properly, push the cable into the reel.

The cable should not be rolled up by turning the reel. !

  • Instructions for use
  • It is absolutely vital to ensure that the PipeControlStation-Camera does not come into contact with chemicals, current, moving or hot objects. This can damage the device and put its user at risk of serious injury.
  • The camera head is not acid-resistant or Ö reproof.
  • The PipeControlStation-Camera must not be used for medical examinations/examining people.
  • The unit is not suitable for taking measurements close to dangerous voltages. Therefore always make sure that conductive parts are at zero potential when carrying out measurements in the vicinity of electrical systems. Safe isolation from the power supply and precautions to prevent systems being switched on again must be ensured by implementing suitable measures.
  • Clean the push rod with a damp cloth before rolling it up.
Page 4 of the Laserliner PipeControlStation-Camera user manual — Guarantee, product care and disposal
Page 4 · click to enlarge
Page 4

PipeControlStation-Camera

Technical dataSubject to technical alterations. 05.13. Type of cameraCMOS image sensor Camera headø 28 mm, water-resistant Protection classIP 68 (immersion depth 20 m, 1h) Camera resolution640 x 480 pixels Field of vision100° Focal depth5 ... 60 cm Reel diameter39 cm Cable diameter5,8 mm Cable length30 m Minimum bending radius70 mm Metre counter accuracy± 2 cm Operating temperature-10 … 60°C Storage temperature-20 … 70°C Weight (without accessories)4,7 kg Dimensions (W x H x D)435 mm x 410 mm x 256 mm

Guarantee, product care and disposal

This device complies with all necessary standards for the free movement of goods within the EU.

This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.

Further safety and supplementary notices at: www.laserliner.com/info

Ask about the Laserliner PipeControlStation-Camera

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Laserliner PipeControlStation-Camera

Be the first to ask — other owners or our team will answer.

Original document

Laserliner PipeControlStation-Camera manual PDF

92 pages·881 KB·Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…