This device, completely automatic, is used to measure and control in a non-invasive way the value of blood pressure (systolic and diastolic), the heart rate and the presence of arrhythmias.Blood pressure is the force exerted by blood on the arteries. This force varies constantly depending on heartbeat. When the heart contracts, blood pressure is at its highest (systolic blood pressure value) whilst at the end of the heart’s “relaxation period”, the value is at its lowest (diastolic blood pressure value). Circuits within the cuff sense the small oscillations in pressure against the cuff produced by the expansion and contraction of the arteries in the arm in response to each heart beat. The amplitude of each pressure waves is measured, converted to millimeters of mercury, and displayed on the LCD as a digital value. Blood pressure is influenced by many factors: smoke, stress, physical activity, eating, the time of day… The arrhythmia, or irregular heart rate, can be caused by frequent anxiety statuses, specific emotional statuses, excessive use of alcohol, thyroid noises, etc. It can be a symptom of a specific physical or psychical condition (temporary noise) or of a real and proper heart disease. Always refer to a physician in case the blood pressure monitor shows the symbol for irregular heart rate, in order to establish the most suitable treatment to be followed. Accurate and easy to use, this device enables even the elderly and less expert to measure blood pressure in the comfort of their own home; its quick and reliable results enabling pressure values to be checked daily. Laica S.p.A. - Viale del Lavoro, 10 - Fraz. Ponte 36021 Barbarano Vicentino (VI) - ITALY Made in China
2) In the case of cardiocirculatory illnesses, the measurements could be falsified; the same could happen with very low blood pressure, problems with blood supply, arrhythmia or other pre-pathological conditions. 3) Do not use near to strong magnetic fields. It must be kept well away from radio equipment or mobile phones. 4) Pressure varies from person to person, and increases or decreases every day, depending on the stress the heart is subjected to. Normally pressure is low during the night, during sleep or during relaxation, and it is higher during the day, when we smoke, during physical exercise, under effort, when we are anxious or tense. Blood pressure tends to increase with age and depends greatly on the individual way of life. It is well known that stress, obesity, excessive intake of salt and alcohol all contribute to increase arterial pressure. The blood pressure value measured at home tends to be lower than that measured at the hospital, in the clinic, or by your doctor. This occurs because one is usually anxious at the hospital and relaxed at one’s home. 5) Keep the batteries out of the reach of children.
At the end of each measurement, the measured pressure data are compared with the above mentioned table. The segments appearing on the left of the display indicate the classification of the blood pressure values: Optimal green color Normal green color Limit range green color Light high blood pressure yellow color Moderate high blood pressure orange color Moderate high blood pressure red color Measured values lower than 105 mmHg (systolic) and than 60 mmHg (diastolic) indicate a high blood pressure status. It is suggested to refer to a physician.
CORRECT MEASURING METHOD Many factors determine variations in arterial pressure: physical exercise, eating, agitation, changes in temperature and emotional stress. Daily fluctuations of 25 / 50 mmHg are common. In order to get an accurate blood pressure reading, follow the instructions below: 1) Sit on a chair, relax and try to keep still for at least 5/10 minutes before taking a reading. 2) Remove clothing and jewellery from the arm or wrist before applying the armlet. 3) Avoid eating, smoking and drinking (above all alcoholic drinks), sports training and having a bath before performing the measurement. All these factors influence the measurement result. 4) Rest the arm on the table so that the armlet is on a level with the heart. The arm must be stretched out naturally and must be kept still. 5) Place both feet on the ground. 6) Remember that the blood pressure changes during the day. Try to effect more measurements during the day for better understanding
CLASSIFICATION OF BLOOD PRESSURE VALUES The following table has been developed by the World Health Organization (WHO), a special agency of the United Nation for health issues. RANGE SYSTOLIC DIASTOLIC MEASURES Optimal 105 - 120 60 - 80 self-measurement Normal 121 - 130 81 - 85 self-measurement Limit range 131 - 140 86 - 90 refer to a physician Light high blood pressure 141 - 160 91 - 100 refer to a physician Moderate high blood pressure 161 - 180 101 - 110 refer to a physician Severe high blood pressure beyond 180 beyond 110 refer to a physician
BEFORE STARTING TO USE THE DEVICE, PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY FROM COVER TO COVER AND KEEP IT SAFE FOR FUTURE REFERENCE.

the reactions of your body to the different moments of your day (after a physical activity, during the job, after the meals…). 7) Do not take only one measurement. At least two measurements should be taken, wait at least 10/15 minutes between the two measurements. More measurements, taken over a long period of time will give you a better indication of your blood pressure. 8) Should an unpleasant feeling occur during the measurement, stop immediately the device with the “O/I” button.
3) Place the cover back to its position. At this point, proceed with the setting of memory area, date and time, as shown in the paragraph “Memory area and date/time setting”. When the display shows the battery symbol ( ), or the device emits 4 short acoustic signals and does not inflate the armband, it is necessary to replace the batteries since they are flat. 4) Remove the flat batteries sliding the cover of the battery compartment in the arrow direction. Extract the batteries and dispose them as special waste at the collection point indicated for recycling. For further information concerning the disposal of used batteries, refer to the store where the device containing the batteries was purchased, the Municipality or the local waste disposal service. Caution: For safety reasons, it is recommended never to allow children younger than 12 years to remove the batteries.
When batteries are inserted or replaced, it is necessary to set the date and time once again as described at points 1, 2, 3, and 4.
The segments appearing on the left side of the display indicate the classification of the blood pressure values (see paragraph “CLASSIFICATION OF BLOOD PRESSURE VALUES”). When the measurement has ended, the device emits a short acoustic signal. Automatic re-pressurisation The initial pre-set pressure value is 190 mmHg. If the pre-set pressure is deemed insufficient in the preliminary measurement phase, or if the hand or wrist is moved, the unit performs the inflation once again up to 250 mmHg. The automatic repressurization is repeated until a valid measurement is performed. However, this is not an evidence of damage.
HOW TO WRAP THE ARMLET AROUND THE ARM 1) Rest the armlet on a flat surface with the fastener strip (Velcro) facing down. Make sure the Velcro fastening is on your left and the armlet’s tube on your right. 2) Insert the end of the armlet through the ring at the other end by about 5 cm. 3) Wrap the armlet around the left arm and secure it in place using the Velcro fastening. The edge of the armlet must be approx. 1-2 cm above the elbow joint and the palm of the hand must face up. The armlet must be snug around the arm (there must be enough room to fit one finger between the armlet and the arm), but not too tight. If the armlet is wrapped too tightly or is too loose, blood pressure readings may be inaccurate. Do not roll sleeves up the arm or blood flow will be impeded, resulting in inaccurate measurements.
MEMORY AREA AND DATE/TIME SETTING 1) With off device, press the “SET” key; the last selected memory area ( , , , ) blinks on the display. To select the desired memory area, press the keys “-” “+” and confirm the selection pressing the “SET” key. Now, the number related to the month blinks on the display. Use the keys “+” and “-” to adjust this value: by keeping them pressed, the scrolling of the numbers becomes faster. Press the “SET” key to confirm it. 2) Now, the day blinks: adjust using the keys “+” “-” and confirm with the “SET” key. 3) Now, the hours blink: adjust using the keys “+” “-” and confirm with the “SET” key (the display shows the time in 12-hour format). 4) Now, the minutes blink: adjust using the keys “+” “-” and confirm with the “SET” key. Then, turn off the device pressing the “O/I” key.
Make sure the batteries are charged. Low or dead batteries decrease the efficiency of the pump, which then cannot provide enough pressure in the preset time interval. For this reason, ERR will appear. Replace the batteries.
HOW TO TAKE MEASUREMENTS 1) Plug the tube into the air connector. 2) Keep the “O/I” key pressed until you hear an acoustic signal. On the display, all function symbols switch on, just for few seconds. The symbol “ ” indicates that the device is ready for the measurement. The armband will start to inflate automatically and will stop when the right level is reached. Try to stay relaxed, without talking or moving. Caution: If after the last measurement some air remained in the armband, the display shows the symbol “ ” till the device stabilizes the pressure. 3) The armband deflates automatically and the display shows the following values sequentially: systolic, diastolic, pulse, date, and time of the measurement, the symbol ( ) only in case an irregular heartbeat is detected (arrhythmias).
MEMORY FUNCTION This device can store up to 30 measurements in each memory area (4 memory areas). After each measurement the following values are stored automatically: diastolic, systolic, pulse, date and time, memory number, reference segments for the classification of the blood pressure values (see paragraph “CLASSIFICATION OF THE BLOOD PRESSURE VALUES”), the possible presence of an irregular pulse (arrhythmias) ( ), and the average of the measurements. To call up the measurements stored in the last selected memory area, it is
INSERTING/REPLACING THE BATTERIES 1) Slide the battery cover in the direction of the arrow. 2) To install or replace the batteries, consider the indicated polarity.

Now, keep the key “+” or “-“ pressed and then press the “SET” key for about 3 seconds; the device emits a short acoustic signal and the display shows “---“. Now all data related to the previously selected memory area have been deleted. To delete the data for another memory area, repeat the operation above, recalling the memory area involved.
: reference segments for the classification of the blood pressure values
INDICATORS On the display, the following symbols may appear:
“ ”: MEMORY AREA No.1: It appears when the measurement is stored in the first memory area.
“ ”: MEMORY AREA No.2: It appears when the measurement is stored in the second memory area.
“ ”: MEMORY AREA No.3: It appears when the measurement is stored in the third memory area. “ ”: MEMORY AREA No.4: It appears when the measurement is stored in the fourth memory area.
Err : It was not possible to perform the measurement due to arm movements, wrong position, other reasons...See paragraph “CORRECT MEASUREMENT METHOD”.
: Exhaust batteries. Replace them.
DELETING THE STORED DATA Deleting all data stored in a memory area. With off device, call up the own memory area by pressing the “SET” key and then the keys “+” and “-“; then, turn off the device by pressing the “O/I” key.
SPECIAL CASES If the following circumstances occur: 1) After pressing the “O/I” key the reading does not start. • Check the batteries and replace them if needed
: indicator of the pulse rate during the measurement
: indicator of irregular pulse

buying a new device of the same type to be used with the same functions. If the appliance to be disposed of is less than 25 cm, it can be returned to a retail location that is over 400 m² without having to purchase a new, similar device. This procedure of separated collection of electric and electronic devices is carried out forecasting a European environmental policy aiming at safeguarding, protecting and improving environment quality, as well as avoiding potential effects on human health due to the presence of hazardous substances in such equipment or to an improper use of the same or of parts of the same. Caution! The wrong disposal of electric and electronic equipment may involve sanctions.
Warranty decays after 2 years from the purchase date. In this case, technical service interventions will be carried out against payment. Information on technical service interventions, under warranty terms or against payment, may be requested by writing at info@laica.com. Repair or replacement of products covered by the warranty terms are free of charge. In case of faults, refer to the dealer; DO NOT send anything directly to LAICA. All interventions covered by warranty (including product replacement or the replacement of any of its parts) shall not be meant to extend the duration of the original warranty period of the replaced product. The manufacturer cannot be made liable for any damages that may be caused, directly or indirectly, to people, things and pets resulting from the inobservance of the provisions contained in the suitable user manual, especially with reference to the instructions related to installation, use and maintenance of the equipment. Being constantly involved in improving its own products, Laica reserves the right to modify its product, totally or partially, with reference to any production need, without that this involves any responsibility whatsoever by Laica or its dealers.
figure indicates the degree of protection against penetration by solid foreign bodies (from 0 to 6) and the second figure the degree of protection against penetration by liquids (from 0 to 8).
ELECTROMAGNETIC COMPATIBILITY This device complies with current regulations relating to electromagnetic compatibility (EMC) and has been designed to be used in the home. Its emissions are extremely small and are unlikely to generate interference with other equipment. In the event that it is to be used in close proximity to other equipment, it is recommended to follow the instructions given in the tables at the end of the instructions for use. Certain mobile communications devices and radio systems may have an effect on the operation of this device. In cases where there are anomalies during operation, it is recommended to distance the device from any other equipment that could cause electromagnetic interference and check for the restoration of performance. In all cases, in the event of doubt, contact Customer Support or see the tables relating to electromagnetic emissions at the end of these instructions.
WARRANTY This equipment is covered by a 2-year warranty starting from the purchase date, which has to be proven by means of the stamp or signature of the dealer and by the fiscal payment receipt that shall be kept enclosed to this document. This warranty period complies with the laws in force and applies only in case the consumer is an individual. Laica products are designed for domestic use only; therefore, their use for commercial purposes is forbidden. The warranty covers only production defects and does not apply, if the damage is caused by accidental events, misuse, negligence or improper use of the product. Use the supplied accessories only; the use of other accessories invalidate the warranty cover. Do not open the equipment for any reason whatsoever; the opening or the tampering of the equipment, definitely invalidate the warranty. Warranty does not apply to parts subject to tear and wear along the use, as well as to batteries, when they are included.
DISPOSAL PROCEDURE (Dir. 2012/19/Eu-WEEE)
The symbol on the bottom of the device indicates the separated collection of electric and electronic equipment. At the end of life of the device, do not dispose it as mixed solid municipal waste, but dispose it referring to a specific collection centre located in your area or returning it to the distributor, when