Region Voice Fax Address Web Site
Grass Valley, Inc. 400 Providence Mine Rd. P.O. Box 599000 Nevada City, CA 95959− 7900 USA
Pacific Operations +852−2585−6688 Support: 852−2585−6579
U.K., Asia, Middle East +44 1753 218 777 +44 1753 218 757
France +33 1 45 29 73 00
Germany, Europe +49 6150 104 782 +49 6150 104 223
Online User Documentation — Current versions of product catalogs, brochures, data sheets, ordering guides, planning guides, manuals, field engineering bulletins, and release notes in .pdf format can be downloaded.
FAQ Database — Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions (FAQ) database.
Copyright Grass Valley, Inc. All rights reserved. All specifications subject to change without notice. This product may be covered by one or more U.S. and foreign patents.
ii CM 4000 Installation and Operating Manual
+852−2802−2996

= New or revised material
Preface xxv
Safety Summary xxvii
Regulatory Notices xxxi
KEMA Certificate xxxiv
Section 1 − Introduction 1−3
CM 4000 System Controller 1−3 Control Functions 1−4 Distribution Switcher Control 1−4 Pathfinding Option 1−4 “Remote” (Serial Control) Router Interface Option 1−4 Integration with Master Control 1−4 Machine Control (JupiterXPress only) 1−4 External Control Protocols 1−4 Control panels 1−5 Switcher Control Panels 1−5 Machine Control Panels 1−6 Software Control Panel Suite (GUI Control Panel) 1−6 Tally 1−6 Status Displays 1−7 Under Monitor Displays 1−7 VGA Status Display 1−7 File Server (Configuration PC) 1−8 System Logger 1−8 Jupiter Configurator (Table Editor) 1−8 Specifications 1−9
CM 4000 Installation and Operating Manual iii

Electrical 1−9 CM 4000 Control Module 1−9 VTR, Control Panel, General Purpose Interface Buses 1−11 Matrix Router Control Buses 1−11 Control Panels 1−12 SlimLine Under Monitor Display Components 1−13 File server 1−14 PC 3000 Specifications (Minimum) 1−14 Equipment Dimensions 1−14 CM 4000 System Controller 1−14 CB 3000 Control Buffer 1−14 Control Panels 1−14 SlimLine Under Monitor Status/Tally Display Components 1−15 PC 3000 File Server 1−15 Control Panels for Custom Mounting 1−15 System Limitations 1−16 Maximum Number of Logical Levels 1−16 CP 38xx Control Panel 1−17 CM 4000 Serial Bus Loading 1−17 Base Load Factors 1−17 Fixed Load Factors 1−18 Calculating Loading 1−18 Example 1−20 Determine the Base Multiplier 1−20 Ordering information 1−22 General Purpose Systems Interfaces 1−22 Control Cables 1−22 SlimLine Under Monitor Status/Tally Displays 1−23 Additional Hardware Part Numbers 1−23 Control System Software Options 1−24 AccuSwitch Frame−Accurate Automation Solution 1−25 Software Control Panel Suite Packages 1−26 Software Packages − Key Features 1−27
Section 2 − Hardware Installation 2−1
Unpacking and Inspection 2−1 110/230 VAC Selection 2−1 CP 300 Series Control Panels 2−1 File Server 2−1 Rack Mounting 2−1 CM 4000 Connection to Distribution Switchers 2−3 JupiterXPress application − connection to Crosspoint Bus router 2−3 CC 2010 Matrix (Crosspoint Bus) Cable 2−4 CB 3000 Control Buffer 2−6 VDE EMI/RFI Modifications to Matrix Cables 2−7
CM 4000 Installation and Operating Manual iv

System protection features 2−7 Alarm Modes 2−7 Single CM installation 2−8 Redundant CM installation 2−8 Manual Changeover 2−8 Replacement of a Failed Redundant Unit 2−8 Installing Redundant CM 4000 Control Modules 2−8 BOP 4000 Break Out Panel kit Cables 2−10 Connection to Serial−Control Routers 2−11 Triton Systems 2−13 Software Configuration 2−14 SMS 7000 Connections 2−15 Software Configuration 2−15 Jupiter Control of Encore 2−17 Non−Redundant Installation 2−17 Cabling 2−17 Software Configuration 2−19 Redundant Installation 2−19 Double−Y Cable 2−20 Software Configuration (Redundant Systems) 2−22 Horizon Connections 2−23 Datatek D−2000/2166 Connections 2−24 Utah Scientific Party Line Connection Using UDI−1B 2−25 Nexus Audio Routing System 2−27 Logical Level Mapping 2−29 Data Matrix Switching 2−30 Hardware Connections 2−30 Software Configuration 2−30 Connection to Multiple Crosspoint Bus Distribution Switchers 2−31 Connection Using a Single CM 4000 2−31 Dedicated CM 4000 Per Switcher 2−32 Connection to Multiple Distribution Switchers with Path Finding 2−33 Sequential Path Finding (Path Finding Using Sequential Wiring) 2−33 Non−sequential Path Finding (Path Finding Using Non−sequential Wiring) 2−33 . Installing File Server PC 2−36 Jupiter LAN 2−36 Printer 2−36 Software Installation 2−36 Installing “Remote” PC on LAN 2−36 Installing Control Panels 2−37 Connections t0 CM 4000 2−37 Switcher Control Panels 2−38 CP 300 Series 2−38 CP 300 24 X 1 Single Bus Control Panel 2−38 CP 310 24 X 8 Eight Bus Control Panel 2−39 CP 320 Push Button Control Panel 2−40
CM 4000 Installation and Operating Manual v

CP 328 Push Button Control Panel 2−40 CP 330 Control Panel 2−41 CP 330/6 48 x 6 Six Bus Control Panel 2−41 CP 3000 Switcher Control Panel and CP 3010 Expansion Panel 2−42 CP 3020 Push Button Control Panel 2−43 CP 3021 Push Button Expansion Panel 2−43 CP 3800 Eight Character Control Panel 2−44 CP 3808 Control Panel 2−45 Hardware installation 2−45 Software configuration 2−45 Operation 2−45 CP 3824 Control Panel 2−46 Hardware installation 2−46 Software configuration 2−46 Operation 2−46 CP 3830 Control Panel 2−47 Hardware installation 2−47 Software configuration 2−47 Operation 2−47 CP 3809 Expansion Panel 2−48 Hardware installation 2−48 Software configuration 2−48 Operation 2−48 CP 3832 Control Panel 2−49 Hardware Installation 2−50 Software Configuration 2−50 CP 3864 Control Panel 2−51 Hardware Installation 2−52 Software Configuration 2−52 Source/Destination Expansion 2−53 CP 3810 Panel 2−54 Hardware Installation 2−54 Software Configuration 2−54 Operation 2−55 JEP 100 Jupiter / Encore Control Panel 2−55 Installing Machine Control Panels 2−56 MC 3000 Machine Control Panel and CP 3010 Expansion Panel 2−56 MC 3010 Machine Control Panel 2−57 Preparing and Installing Button Labels 2−58 CP 3020/1
MC 3020D/L VC 3020 2−58 Replacing Button Bulbs 2−58 CP 300 Series Control Panels 2−58 CP 3800 Series Control Panels 2−59 Testing Bulbs 2−59
CM 4000 Installation and Operating Manual vi

CP/VC 3020 2−59 MC 3010 2−59 CP 300 / 3800 Series Panels 2−59 Connection to Thomson/Philips DD Series (“Diamond”) 2−60 Connection to VTRs and Other Machines 2−61 Connection to Sony and Sony−compatible VTRs 2−61 Sony Installation Notes 2−61 Other VTRs 2−61 Remote Control via Modem 2−62 Jupiter Configuration 2−62 Installing CM 4000 VGA Status Display 2−63 Serial Data Cables 2−63 VDE EMI/RFI Modifications to Serial Data Cables 2−64 Sync Reference Cables 2−64 Time Code Connections 2−64 Connection to Saturn Master Control Switcher 2−65 MI 3040 Tally Installation 2−67 Tally Systems 2−67 MI 3040 Hardware Overview 2−68 Relay Outputs 2−68 Status Inputs (Opto−isolators) 2−68 MPK Bus Connections 2−68 Current Sources 2−68 Example Of Saturn Tally System 2−69 Examples Of Jupiter Tally systems 2−70 Connection to Systems with Saturn Master Control Switcher 2−70 Connection to Systems with Non−Saturn, Non−MCS 2000 Master Control
Switcher 2−70 Software Configuration 2−70 SlimLine UMD Tally 2−70 MI/MC 3040 Hardware Overview 2−77 Optoelectronic Relays 2−77 Relay Control 2−77 Optical Couplers 2−77 Utility Connections 2−78 Under Monitor Displays 2−81 Connection to Systems with Jupiter−Controlled Router Only 2−83 Software Configuration 2−83 Connection to Systems with Saturn Master Control Switcher 2−84 Software configuration 2−84 Connection to Systems With Saturn Master Control AND Production Switcher 2−85 Software Configuration 2−86 Connection to Automation and Other Systems 2−87 Connection to Devices Using “ESswitch” Proposed ESbus Routing Switcher
Dialect 2−87
CM 4000 Installation and Operating Manual vii

Connection to Devices using Jupiter ASCII Computer Interface Protocol 2−88 Encore Control of Jupiter 2−91
Section 3 − Software Installation 3−1
Section 4 − Jupiter Network Suite Control Console 4−1
Installation 4−1 Launching the Control Console 4−1 JNS Applications Group 4−3 JNS Tools Group 4−3 JNS Utilities Group 4−4
Section 5 − Configurator 5−1
Starting the Configurator 5−1 Closing the Configurator 5−2 Configurator Editing Guidelines 5−3 Automatic Table Entry 5−3 Entry/edit Within a Jupiter Table 5−3 Reordering Jupiter Tables 5−4 Find / Fill / Increment 5−5 Copying and Pasting a Block 5−5 Keyboard Shortcuts 5−6 Copy and Paste Rows Between the Windows Clipboard and Jupiter 5−6 Jupiter Naming Rules 5−7 Configuration Set Management 5−8 Modifying and Downloading a System Configuration Set 5−8 Copying a Configuration Set for Editing 5−10 Making the Desired Modifications to the Set 5−11 Using the “Numeric” Sets for Quick Switcher Checkout 5−11 Validating, Compiling, and Activating (Downloading) a Configuration Set 5−13 Download Now / Reboot Later (“Pending Reboot”) 5−15 Download now / Reboot later procedure 5−16 Mismatch Indicator 5−18 Troubleshooting 5−20 Error Conditions 5−20 Program Crash Recovery 5−20 Deleting Jupiter Software 5−20 Re−installing Jupiter Software 5−20 Zipping a Configuration Set 5−20 Zipping a Configuration Set with Diagnostic Information (“Support Package”) 5−21 Printing 5−21 On−line Help 5−21 Inadvertent Loss of Power 5−21
CM 4000 Installation and Operating Manual viii

Disconnecting File Server from LAN 5−21 Passwords 5−22 Changing Passwords 5−25 Setting Password Levels for Control Panels 5−26 Setting Password Levels for Switcher Outputs 5−26 Force Unprotect/Unlock 5−26 Network Description 5−27 Automatic Table Entry 5−28 Entering Descriptions of Controller Boards 5−28 Serial Protocol 5−30 Entering Protocol for Controller Board Ports 5−31 Saturn Video Processor − Entry for MPK Port 5−34 Switcher Description 5−35 Entering Switcher Levels Descriptions 5−36 Point−to−Point Data Switching Options 5−45 Data switching − off time between switches 5−47 Switcher Input 5−48 Split Switching 5−50 Entering or Editing Input Names and Numbers 5−51 Data Switching Applications 5−52 Controller / Tributary Reassignment 5−53 CP Input and Output Sets and Control Panel Operation 5−54 Switcher Output 5−55 Entering or Editing Output Names and Numbers 5−56 Setting Password Levels for Switcher Outputs 5−57 CP Level Set 5−58 A Note Concerning Level Numbering and External Control Computers Using
ASCII Protocol 5−60 CP Input Set 5−62 Primary (P) and Indirect (i) Status Instructions (“Split Mnemonics”) 5−64 Entering or Editing a CP Input Set 5−66 Copying a CP Input or Output Set for Use with a Different Panel Type 5−77 . CP Output Set 5−78 Overview 5−78 Copying a CP Output Set for Use with a Different Panel Type 5−80 Entering or Editing a CP Output Set 5−81 Multiple Switcher Installations 5−94 CP Override Set 5−96 Defining Overrides 5−97 CP Sequence Set 5−99 Defining Sequences 5−100 CP Category Set 5−101 Changing the Category Set Associated with an Input or Output Set 5−105 MPK Devices 5−107 Setting Up a Switcher Control Panel for Full−Matrix, Multi−Bus, or
Single−Bus Control 5−112
CM 4000 Installation and Operating Manual ix

Setting Password Levels for Control Panels 5−113 VGA Status Display Control Panel Entries 5−114 Force Unprotect / Force Unlock Password 5−114 Displaying Time Code on an MC 3000 Associated with a VGA Status Display 5−114 MI 3040 General Purpose / Tally Interface Entries 5−115 Tally Interface Applications 5−115 External Control of Saturn Master Control Switcher (“MI 3040IO” application) 5−115 Under Monitor Display Entries 5−116 Systems with Jupiter−Controlled Distribution Switcher Only 5−116 SlimLine Applications 5−116 RP 1/2/3 and RP 1/2/3 C Applications 5−117 Systems with Saturn Master Control Switcher 5−118 Systems with Saturn Master Control and Production Switcher 5−119 Permanent Display of Mnemonic 5−122 Front Panel Configuration 5−122 Jupiter Configuration 5−122 External Control Device Entries 5−123 Encore Control of Jupiter 5−123 DD Series Switchers 5−123 Automation Control 5−125 JupiterXPress 5−125 Accuswitch 5−125 CP 3830 Dual Configuration 5−126 Dedicated Output Panel 5−126 CP 3832 / 3864 Multi−Panel Applications 5−127 Single−Bus Application 5−127 128 X 1 control station 5−127 X−Y Application (with Balanced Split Panel) 5−128 48 X 16 control station 5−128 X−Y Application (No Split Panel) 5−129 64 X 32 control station 5−129 X−Y Application (No Split Panel) 5−130 128 X 128 control station 5−130 CP 3810 Applications 5−131 Multi−Bus Control 5−131 Single Bus Control (“CP 3810L”) 5−132 X−Y Application 5−133 Single Bus Status Only (Stand−alone) (“CP−3810L”) 5−134 Machines 5−135 Machine Control 5−139 Saturn Master Control Switcher 5−140 Assigning (Linking) Machines to Control Panels 5−141 Example of Machine Control Tables Setup 5−143 Operational Sequence for Linkage 5−144
CM 4000 Installation and Operating Manual x

Default (Semi−permanent) Linkage 5−146 Linkage for Machines That Do Not Enter the Routing Switcher 5−147 Start/Stop machine control using Expansion Panels 5−148 VGA / MC 3000 Status Display Table Entries 5−148 Saturn Master Control Switcher 5−148 Delegation Groups 5−149 Permanent Delegation 5−149 Status Display Headers 5−150 VGA Status Display Table 5−151 Tally 5−152 Relay Description 5−152 Tally Dependency 5−158 Overview 5−158 Basic Tally System with Saturn Master Control Switcher 5−160 Direct Connection to Transmitter 5−160 Saturn (“MCS_TLY”) entries 5−160 Indirect Connection to Transmitter 5−162 Unqualified output 5−162 Saturn (“MCS_TLY”) entries 5−162 Configuration for Systems with Saturn Master Control Switcher and
Production Switcher 5−164 Direct Connection to Transmitter 5−164 Saturn (“MCS_TLY”) entries 5−164 Production Switcher Entries 5−166 Indirect Connection to Transmitter 5−168 Unqualified Output 5−168 Saturn (“MCS_TLY”) Entries 5−168 Production Switcher Entries 5−168 Configuration for Systems with Non−Saturn Master Control Switcher 5−170 Example of Tally System Operation 5−172 Sequential Path Finding 5−174 Path Finding Data Table 5−175 Switcher Input Tables 5−176 Path Finding for Three or More Switchers 5−178 Path Finding Between Analog and Digital Equipment 5−181 Automatic Conversion of Separate Analog Signals to Combined Digital Signals 5−181 Non−Sequential Path Finding 5−185 Exclusion 5−188 Y Line Table (DM 400/400A) 5−189 Time Standard table 5−190 Video Reference Table 5−190 CM VGA Options 5−190
Section 6 − Control Panel Operation 6−1
CP 300 24 x 1 Single Bus Control Panel 6−1
CM 4000 Installation and Operating Manual xi

CP-310 24 x 8 Eight Bus Control Panel 6−2 CP 320 Push Button Control Panel 6−3 CP 328 Push Button Control Panel 6−4 CP 330 Control Panel 6−4 CP 330/6 48 x 6 Six Bus Control Panel 6−5 CP 300 Series Diagnostics 6−6 CP 300/310/330 6−6 Button/Lamp Test 6−6 Lamp Self−Test 6−6 CP 330/6 6−6 CP 320/328 6−6 CP 3000 Switcher Control Panel 6−7 Override Input Selection 6−7 Category and Number Input Selection 6−8 Protect Output 6−9 To Protect an Output 6−9 To Unprotect an Output 6−10 Lock Output 6−11 To Lock an Output 6−11 To Unlock an Output 6−11 Additional Protect/Lock Information 6−12 Chop Inputs 6−13 Additional Chop Information 6−13 Levels Selection (Split Switching) 6−14 De−selecting Switcher Levels 6−14 Switching Different Inputs with a Single TAKE Command 6−15 An Alternate Method of Split Switching 6−15 Menu Selections 6−15 STAT — Display Output Status 6−16 SEQ — Select Input Sequences 6−17 AUD — Audio Modes 6−18 OUT — Display/Change Output 6−20 DIAG — Control Panel Diagnostics 6−20 Display Self−Test 6−20 Keypad Self−Test 6−20 DEF — Re−define Input Overrides 6−21 ID — Display Control Panel Device Address 6−21 Passwords 6−22 Single−Event Password Entry 6−22 Long−Term Password Entry (PWD — Login) 6−22 Raising Password Level to Maximum (for Force Unprotect/Unlock) 6−22 . . . LOG — Logout (CP 3000 Panel Only) 6−23 CP 3010 Expansion Panel Operation 6−24 CP 3010 as Companion to CP 3000 Switcher Control Panel 6−24 Dynamic Assignment of Outputs to the TAKE Keys 6−24 Permanent Assignment of Outputs to the TAKE Keys 6−25
CM 4000 Installation and Operating Manual xii

Machine Control 6−25 CP 3020 Push Button Control Panel operation 6−26 LOCK Mode 6−26 CHOP Mode 6−26 Button/Lamp Test 6−26 CP 3800A Eight Character Control Panel 6−27 Overview 6−27 Display 6−28 Soft Key Group 6−28 Menu / Control Group 6−28 Menu Mode Group 6−29 Panel Control Group 6−30 Category and Number Group 6−30 Operation 6−30 Multiple Destination Mode 6−31 Scrolling to Other Pages 6−31 Selecting Destination(s) and Making a Switch 6−32 Adding or Changing a Destination Soft Key Assignment 6−34 Erasing a Destination 6−35 Entering Single Destination Mode 6−36 Single Destination Mode (“Single−Bus Control”) 6−37 Scrolling to Other Pages 6−38 Selecting a Destination 6−38 Making a Switch 6−40 Level Selection Mode (“Split” or “Breakaway” Switching) 6−41 Making a Split Switch—Multiple Destination Mode (“DEST” Button OFF) 6−42 Making a Split Switch—Single Destination Mode (“DEST” Button ON) 6−42 Audio Control Mode (Venus Special Stereo Switching) 6−43 To Perform a Special Stereo Switch: 6−44 Menu Mode 6−45 VTR Control 6−45 Single Destination VTR Control 6−45 Multiple destination VTR Control 6−46 Scrolling to Other Pages 6−46 Diagnostics 6−47 Info 6−47 Baud Rate 6−47 Panel ID 6−47 MPK Test 6−48 Illumination adjustment 6−48 Burn In 6−48 Keyboard test 6−48 Display test 6−48 LED test 6−48 Chop 6−49
CM 4000 Installation and Operating Manual xiii

Config 6−50 Sticky Outputs 6−50 Sticky Levels 6−50 Sticky Audio 6−50 Category Prompting 6−51 Password Levels 6−51 Password Level Request During TAKE 6−52 Override Mode 6−53 Executing Overrides 6−53 Defining Overrides 6−54 Entering Define Mode 6−54 Creating the override definition 6−54 Viewing Override Definitions 6−55 Erasing An Override 6−56 Sequence Mode 6−57 Executing Sequences 6−57 Defining Sequences 6−57 Entering Define Mode 6−58 Creating the Sequence Definition 6−58 Viewing Sequence Definitions 6−60 Erasing a Sequence 6−60 Protect/Lock Mode 6−61 Tie Line Status and Operation 6−63 Tie Lines Used Up Warning 6−63 Error Messages 6−63 CP 3808 Control Panel 6−64 Home Mode 6−64 Source Entry Mode 6−64 Destination (Output) Selection 6−65 Source Selection 6−66 Operation with Expansion Panels 6−66 Level Breakaways (Split Switching) 6−67 Level Preset Method 6−67 Level Deselect Method 6−68 Multi−Source, One−Take Splits 6−68 Menu Functions 6−68 Destination Mode — Press MENU Once 6−68 Status Mode — Press MENU Twice 6−69 Audio Status Mode— Press MENU Three Times 6−69 Locking or Unlocking an Output—Press MENU Four Times 6−69 Protecting or Unprotecting an Output—Press MENU Four Times 6−70 Panel ID (Address) Mode—Press MENU Five Times 6−71 Diagnostics Mode — Press MENU Six Times 6−71 LED Test 6−71 Info 6−71 Baud Rate 6−72
CM 4000 Installation and Operating Manual xiv

Panel ID 6−72 MPK Test 6−72 Illumination Adjustment 6−72 Burn In 6−73 Key test 6−73 Display test 6−73 Audio Switching Mode (Venus Special Stereo Switching) 6−74 Passwords 6−75 CP 3810 Expansion Panel Operation 6−75 CP 3824 Control Panel 6−76 Destination Selection 6−76 Source Selection 6−77 Selecting a Source with PRESET On 6−77 Scrolling Through Override Pages 6−77 Flip−flop Operation 6−78 Locking or Unlocking an Output 6−79 Protecting or Unprotecting an Output 6−79 Chop Outputs 6−80 Level Breakaways (Split Switching) 6−81 Breakaway Using Override Keys (PRESET Off) 6−81 Breakaway Using Category/Number Keys (PRESET Off) 6−82 Breakaway Switching − Multi−Level Take 6−83 Checking Status of Multiple Levels 6−83 Breakaway Switching − Sticky Level(s) 6−83 Defining Overrides 6−85 Restoring Override Keys to Default Assignments (Default Select Mode) 6−86 Menu Functions 6−87 Destination Mode — Press MENU Once 6−87 Default Select Mode — Press MENU Twice 6−87 Sticky Mode — Press MENU Three Times 6−87 Panel Name — Press MENU Four Times 6−87 Panel ID (Address) Mode — Press MENU Five Times 6−87 Diagnostics Mode — Press MENU Six Times 6−87 CP 3830 Control Panel 6−88 CP 3830P (CP 3830 with Automatic Preview) 6−88 Destination Selection 6−89 CP 3830 Dual Configuration—Dedicated Output Panel 6−89 Source Selection 6−90 Operation with Expansion Panels 6−90 Flip−flop Operation 6−91 Locking or Unlocking an Output 6−92 Protecting or Unprotecting an Output 6−92 Chop Outputs 6−93 Level Breakaways (Split Switching) 6−94 Level Preset Method 6−94 Level Deselect Method 6−95
CM 4000 Installation and Operating Manual xv

Multi−Source, One−take Splits 6−95 Menu Functions 6−96 Destination Mode — Press MENU Once 6−96 Status Mode — Press MENU Twice 6−96 Audio Mode — Press MENU Three Times 6−96 Panel ID (Address) Mode—Press MENU Four Times 6−97 Diagnostics Mode — Press MENU Five Times 6−97 Audio Switching Mode (Venus Special Stereo Switching) 6−98 To Perform a Special Stereo Switch: 6−98 CP 3832 / 3864 Control Panels 6−100 Passwords 6−100 Single−Bus Operation 6−101 Chop (CP 3864 Only) 6−103 Protecting or Unprotecting an Output 6−103 Locking or Unlocking an Output 6−104 Split Panel Operation 6−106 Operation as a Source or Destination Expansion Panel 6−108 Single−Bus Operation 6−109 Source Expansion Operation (with “balanced Split” 16 x 16 Main Panel) 6−110 Destination Expansion Operation 6−111 Menu Functions 6−112 Destination Mode — Press MENU Once 6−112 Audio Status Mode— Press MENU Twice 6−112 Panel Name — Press MENU Three Times 6−112 Panel ID (Address) Mode — Press MENU Four Times 6−112 Diagnostics Mode — Press MENU Five Times 6−112 LED Test 6−113 Info 6−113 Baud Rate 6−113 Panel ID 6−113 MPK Test 6−114 Illumination Adjustment 6−114 Burn In 6−114 Keyboard Test 6−114 Display Test 6−114 Audio Switching Mode (Venus Special Stereo Switching) 6−115 CP 3832L / 3864L Control Panels 6−117 Passwords 6−117 Single−Bus Operation 6−118 Protect/unprotect functions 6−119 CP 3832L 6−119 CP 3864L 6−119 Split Panel Operation 6−120 Diagnostics Mode 6−121 LED Test 6−121
CM 4000 Installation and Operating Manual xvi

Info 6−121 Baud Rate 6−122 Panel ID 6−122 MPK Test 6−122 Illumination Adjustment 6−122 Burn In 6−123 Keyboard Test 6−123 Display Test 6−123 CP 3809 Expansion Panel Operation 6−124 Dynamic Assignment of Outputs to Expansion Panel Buttons 6−124 Permanent Assignment of Outputs to the Expansion Panel 6−125 Diagnostics Mode 6−125 CP 3810 Expansion Panel Operation 6−126 Multi−Bus Control 6−126 Single−Bus Control 6−129 Switching Procedure 6−129 X−Y Application 6−130 Single−Bus Status Only (Stand−Alone) 6−130 Diagnostics Mode 6−130 JEP 100 Jupiter / Encore Control Panel 6−130 MC 3000 Machine Control Panel and CP 3010 Expansion Panel 6−131 MC 3000 Control Functions 6−132 Using the MC 3000 to Access Sony Auto−Edit Mode 6−133 CP 3010 Control Functions 6−134 MC 3010 Machine Control Panel 6−135 Gang Start 6−135 Diagnostics 6−137 VGA Status Display Operation 6−138 Switcher Output Status Page 6−139 Cursor Mode − Selecting an Output for Control 6−139 Force Unprotect / Force Unlock 6−140 Machine & Delegation Status Page 6−140 Cursor Mode − Selecting a Machine for Control 6−140
Section 7 − Software Control Panel Suite 7−1
Software Installation 7−1 Jupiter Table Entries 7−1 Network Description Table 7−2 Serial Protocol Table 7−3 MPK Devices Table 7−4 Machine Control Table 7−5 Main Screen 7−6 Panel Configuration 7−7 Operation 7−8
Paths Full / Protected / Locked / Excluded Messages 7−8
CM 4000 Installation and Operating Manual xvii

Slaved Machine Control Panel 7−9 Machine Assignment 7−9 Machine Control Buttons 7−10 Time code display 7−10 Full Function Switcher Panel 7−11 To Status a Destination 7−11 To Switch a Source 7−12 Breakaway Switching (“Select” Method) 7−12 Breakaway Switching (“Deselect” Method) 7−13 Audio Modes (Venus Special Stereo Switching) 7−14 Presets 7−16 Direct Take Preset Assignments 7−16 Breakaway Preset Assignments 7−17 Removing a Preset Assignment 7−17 Switching Using the Direct−Take Presets 7−17 Memory 7−18 Saving a Direct Take Setup 7−18 Recalling a Direct Take Setup 7−19 Memory Location Labeling 7−19 Full Function Machine Control 7−20 Machine Assignment 7−20 Machine Control Buttons 7−21 Control Knob and Direction/speed Indicators 7−21 Time Code Display 7−21 Manual Time Code Entry 7−21 Dubs Panel 7−22 To Status a Destination 7−22 Switching Multiple Destinations to the Same Input (Dub Switching) 7−23 . . . Using the Hold Button 7−23 Source/Destination Panel 7−24 To Status a Destination 7−24 To Switch a Source 7−24 Salvo Panel 7−26 Multiple Source/Destination Switching (Salvo) 7−26 Memory 7−27 Saving a Salvo Setup 7−27 Checking a Salvo Setup 7−28 Recalling and taking a Salvo Setup 7−28 Memory Location labeling 7−28 X − Y Panel 7−29 To Status a Destination 7−29 To Switch a Source 7−29
Section 8 − Board Status 8−1
Operation 8−1
CM 4000 Installation and Operating Manual xviii

Refresh 8−2 Menus 8−2
Section 9 − Control Center 9−1
Board Status 9−1 TFTP Status 9−2 Board Info/Control 9−3 Selecting Boards 9−3 Reboot 9−4 Clear PMEM 9−4 Clear Flash 9−4 Post Mortem 9−4 Start Board Override 9−4 Telnet 9−4 Update Board Info 9−4 Menu Commands 9−5 File 9−5 Exit 9−5 Options 9−5 Scan Rate 9−5 Time Sync 9−5 Help 9−5 Configuration 9−6 Simple Set Activation 9−6 Activation Without a Reboot 9−7 Reboot 9−7 Backup Set 9−7
Section 10 − CP Input/Output Set Editor 10−1
Passwords 10−2 Drop−down Menus 10−2 File 10−2 View 10−3 Options 10−3 Selecting a Set for Editing and Download 10−3 Editing Sets 10−4 Editing Category Names 10−5 Creating and Activating a Group of Sets (Select Group) 10−5 Activating (Downloading) a Single Set 10−7 Logging 10−7 Log In/Log Out 10−8 Logging In 10−8 Logging Out 10−8 Options Menu 10−8 Passwords 10−8
CM 4000 Installation and Operating Manual xix

Compare Sets 10−9 Input and Output Set Usage Tables 10−11 Additional Notes 10−11
Section 11 − Force Unlock 11−1
Display 11−1 Unlocking and Unprotecting 11−1 Menus 11−1
Section 12 − Logger and Log Viewer 12−1
Running the JNS Logger 12−1 Running the JNS Log Viewer 12−2 Dynamic Displays 12−3 Static Displays 12−3 Date/Time Filter 12−4 Print/Export 12−4 Notes 12−4
Section 13 − Configuration Upload 13−1
Overview 13−1 Step−by−step Instructions 13−1
Section 14 − Physical Control 14−1
Section 15 − Physical Diagnostic Utility 15−1
Features 15−1 Menus 15−1
File 15−1 View 15−1 Options 15−2 Window 15−2 Help 15−2 Functionality 15−2 File > New 15−2 Selecting By Output 15−4 Selecting By Level 15−5 Physical Data Update 15−6 File > Open 15−6 View Menu 15−6 Input Mapping 15−6 Exception Tables 15−7
Section 16 − Physical Remapping Utility 16−1
Menus 16−1
CM 4000 Installation and Operating Manual xx

File 16−1 System Definition 16−2 View − display the Input or Output Exception tables. 16−2 Start Remapping by Entering Physical Numbers 16−2 Comment Field 16−3 Remapping 16−4 Restoring 16−4 System Definition 16−5 Setting Idle Inputs/Outputs 16−5 Exception Tables 16−6
Section 17 − Router Control Utility 17−1
Configuration 17−1 Displaying Status 17−2 Doing Takes 17−2 Menus 17−2
Section 18 − Router Save/Restore 18−1
Operation 18−1 Saving Router Status 18−1 Restoring Router Status 18−1 Selecting Outputs and Levels 18−2 Menus 18−2
Appendix A A−1
CM 4000 VGA Status Display A−1 Hardware Installation A−1 Summary of Software Configuration Procedure A−2 Custom Display Formatting A−3 VGA Page Description File Definitions A−3 Basic Rules: A−3 Field Definitions A−4 Page Description Examples A−6 Switcher Output Status Page A−6 Switcher Input Status Page A−7 Machine and Delegation Status Page A−8 System Status Page A−8 Tie Line (Path Finding) Page A−9 Tie Line Status Display A−10
Appendix B B−1
Program Restart Procedures B−1 CM 4000 Reset B−1
CM 4000 Installation and Operating Manual xxi

Clearing Parameter Memory (PMEM) B−1 CM 4000 B−1
Appendix C C−1
Console Port Connections and Protocol C−1
Appendix D D−1
Decimal−Hexadecimal−Binary−ASCII Conversion Chart D−1
Appendix E E−1
Mark/Search Commands in Jupiter Control System E−1 MC 3000 Control Panel Operation E−1
Appendix F F−1
“ESbus” Specifications F−1 Mechanical and Electrical Characteristics F−1
Appendix G G−1
CM 4000 AccuSwitch Installation and Configuration G−1 CM 4000/AccuSwitch supported functions G−1 CM 4000/AccuSwitch non−supported functions G−1 CM 4000/AccuSwitch Hardware Installation G−2 Connection to Automation System G−2 Installing 10Base2 LAN Cables G−3 AccuSwitch Software Installation G−7 AccuSwitch Software Configuration G−7 AccuSwitch Time Management G−12 CM 4000 Front Panel Error Codes
CM 4000 Startup and Shutdown Codes G−13
Appendix H H−1
JupiterXPress Configuration Swap Option H−1 Configuration Swap Process H−1
Appendix I I−1
Jupiter Remote PC I−1 Overview I−1 Installation I−1 Additional Network configurations I−5 File server − backup PC I−5 Load sharing I−5
CM 4000 Installation and Operating Manual xxii

Connecting a Remote PC to a Windows XP Server I−5
Appendix J J−1
CP 3000 Control Panel Basic Operation J−1 Input To Output Switching J−1 Lock J−5 Protect J−5
Appendix K K−1
Preparing and activating a replacement CM 4000 K−1 Replacing a Failed Unit K−2
Appendix L L−1
Special Configuration Requirements: Venus DM 400/400A Data Matrix Switching L−1 . . Hardware Connections L−1 Switcher Description Table L−3 Switcher Input and Output Tables L−5 CP Level Set L−6 CP Input And Output Sets L−6 Operation L−6 Point−to−point Data Switching Options L−7 Y line Table − VTR Controller/Tributary Selection L−8 CP Input and Output Sets L−10 Operation L−10
Appendix M M−1
CP 3000/3010 Output Set Work Sheet M−1
Appendix N N−1
Jupiter ASCII Communications Protocol N−1
Appendix O O−1
Venus Monitor Configuration O−1 Hardware Installation O−1 Cabling O−1 VM/DC 400 Combiners O−1 Software Configuration O−2 Operational Sequence for Monitoring O−4
Appendix P P−1
CE 3000 Matrix Control / PL 3000 Party Line Interface
SC 3000 Serial Control / VG 3000 Video Display / Status Generator P−1
CM 4000 Installation and Operating Manual xxiii

Appendix Q Q−1
PS 300 110/220 VAC Power Adaptor Kit Installation Instructions Q−1 Mounting Procedure Q−1
Appendix R R−1
Status and Error Codes R−1 CB 3000 Crosspoint buffer and interface R−1 CM 4000 System Controller Boards R−2 Startup and shutdown codes R−2 CM 4000 front panel error codes R−2 CP 3800 Series Control Panels R−12
Appendix S S−1
TSL UMD Setup Guide S−1
Appendix T T−1
Grass Valley 8964 OMD (On Monitor Display) module T−1 Jupiter Configuration Procedure T−2
Index
CM 4000 Installation and Operating Manual xxiv

About This Manual
This manual provides hardware installation, software configuration, and operating instructions for the Jupiter CM 4000 Control Module and associated control panels.
A printed copy of the manual is normally provided with the system, along with the Routing Products Documentation CD−ROM, part no. 071 8274 xx.
This manual can also be accessed through the Jupiter Configuration Editor “Help” pull−down menu.
CD−ROM 071 8274 xx provides electronic copies of Apex, Jupiter, Saturn, Trinix, Triton, and Venus manuals and field bulletins, including:
Setting Up, Configuring, and Operating a Basic Jupiter Control System (071 8189 00)
Building a Jupiter Tally System from the Ground Up (071 8188 00)
Finding Your Path through Path Finding (071 8187 00)

Current versions of many of these documents are maintained on our web site. See page ii.
Other publications that can be ordered by contacting Grass Valley Technical Support include:
xxvi CM 4000 Installation and Operating Manual

Read and follow the important safety information below, noting especially those instructions related to risk of fire, electric shock or injury to persons. Additional spe- cific warnings not listed here may be found throughout the manual.
Any instructions in this manual that require opening the equipment cover or enclosure are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operat- ing instructions unless you are qualified to do so.
Terms in This Manual
Safety−related statements may appear in this manual in the following form:
xxvii CM 4000 Installation and Operating Manual

The following terms may appear on the product:
The following symbols may appear on the product:
Indicates that dangerous high voltage is present within the equipment enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
Indicates that user, operator or service technician should refer to product manual(s) for important operating, maintenance, or service instructions.
This is a prompt to note fuse rating when replacing fuse(s). The fuse referenced in the text must be replaced with one having the ratings indicated.
Identifies a protective grounding terminal which must be connected to earth ground prior to making any other equipment connections.
Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal.
Indicates that static sensitive components are present which may be damaged by electrostatic discharge. Use anti−static procedures, equipment and surfaces during servicing.
xxviii CM 4000 Installation and Operating Manual

The following warning statements identify conditions or practices that can result in personal injury or loss of life.
Do not service alone — Do not internally service this product unless another per- son capable of rendering first aid and resuscitation is present.
Remove jewelry — Prior to servicing, remove jewelry such as rings, watches, and other metallic objects.
Avoid exposed circuitry — Do not touch exposed connections, components or circuitry when power is present.
Use proper power cord — Use only the power cord supplied or specified for this product.
Ground product — Connect the grounding conductor of the power cord to earth ground.
Operate only with covers and enclosure panels in place — Do not operate this product when covers or enclosure panels are removed.
Use correct fuse — Use only fuse type and rating specified for this product.
Use only in dry environment — Do not operate in wet or damp conditions.
Use only in non−explosive environment — Do not operate this product in an explosive atmosphere.
High leakage current may be present — Earth connection of product is essen- tial before connecting power.
Double pole neutral fusing — Disconnect mains power prior to servicing.
Use proper lift points — Do not use door latches to lift or move equipment.
Avoid mechanical hazards — Allow all rotating devices to come to a stop be- fore servicing.
xxix CM 4000 Installation and Operating Manual

The following caution statements identify conditions or practices that can result in damage to equipment or other property
Use correct power source — Do not operate this product from a power source that applies more than the voltage specified for the product.
Provide proper ventilation — To prevent product overheating, provide equip- ment ventilation in accordance with installation instructions.
Use anti−static procedures — Static sensitive components are present which may be damaged by electrostatic discharge. Use anti−static procedures, equipment and surfaces during servicing.
Do not operate with suspected equipment failure — If you suspect product damage or equipment failure, have the equipment inspected by qualified service personnel.
Ensure mains disconnect — The power cord of this equipment provides the means of disconnection. The socket outlet must be installed near the equipment and must be easily accessible. Verify that all mains power is disconnected before instal- ling or removing power supplies and/or options.
Route cable properly — Route power cords and other cables so that they ar not likely to be damaged. Properly support heavy cable bundles to avoid connector dam- age.
Use correct power supply cords — Power cords for this equipment, if pro- vided, meet all North American electrical codes. Operation of this equipment at volt- ages exceeding 130 VAC requires power supply cords which comply with NEMA configurations. International power cords, if provided, have the approval of the coun- try of use.
Troubleshoot only to board level — Circuit boards in this product are densely populated with surface mount technology (SMT) components and application specif- ic integrated circuits (ASICS). As a result, circuit board repair at the component level is very difficult in the field, if not impossible. For warranty compliance, do not trou- bleshoot systems beyond the board level.
xxx CM 4000 Installation and Operating Manual

Certifications and Compliances
Safety Certification
Category Standard Designed/tested for compliance with:
Safety ANSI/UL 1950−1997 3rd Ed.
Professional Video and Audio Equipment
CAN/CSA−C22.2 No. 950−95
FCC Emission Notice
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, in- cluding interference that may cause undesirable operation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful in- terference to radio communications.
This device has been tested and found to comply with FCC Part 15 Class B limits for a digital device when tested with a representative laser−based fiber optical system that complies with ANSI X3T11 Fiber Channel Standard. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause harmful interfer- ence in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Grass Valley can affect emission compliance and could void the user’s authority to operate this equipment.
xxxi CM 4000 Installation and Operating Manual

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A préscrites dans le Règle- ment sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.
For products that comply with Class A. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Canadian approval includes the products and power cords appropriate for use in the North America power network. All other power cords supplied are approved for the country of use.
Canadian approval includes the AC adapters appropriate for use in the North Ameri- ca power network. All other AC adapters supplied are approved for the country of use.
xxxii CM 4000 Installation and Operating Manual

Laser Safety Requirements
The device used in this product is a Class 1 certified laser product. Operating this product outside specifications or altering from its original design may result in haz- ardous radiation exposure, and may be considered an act of modifying or new manufacturing of a laser product under U.S. regulations contained in 21CFR Chap- ter1, subchapter J or CENELEC regulations in HD 482 S1. People performing such an act are required by law to recertify and reidentify this product in accordance with provisions of 21CFR subchapter J for distribution within the U.S.A., and in accor- dance with CENELEC HD 482 S1 for distribution within countries using the IEC 825 standard.
Laser safety in the United States is regulated by the Center for Devices and Radio- logical Health (CDRH). The laser safety regulations are published in the “Laser Product Performance Standard,” Code of Federal Regulation (CFR), Title 21, Sub- chapter J.
The international Electrotechnical Commission (IEC) Standard 825, “Radiation of Laser Products, Equipment Classification, Requirements and User’s Guide,” governs laser products outside the United States. Europe and member nations of the European Free trade Association fall under the jurisdiction of the Comite European de Normal- ization Electrotechnique (CENELEC).
For the CDRH: The radiant power is detected trough a 7 mm aperture at a distance of 200 mm from the source focused through a lens with a focal length of 100 mm.
For IEC compliance: The radiant power is detected trough a 7 mm aperture at a dis- tance of 100 mm from the source focused through a lens with a focal length of 100 mm.
xxxiii CM 4000 Installation and Operating Manual


Affiliate with the N. V. KEMA in the Netherlands A member of the International Network for Quality System Assessment and Certification “IQNet”
The Quality System of
TBMS TBMS 400 Providence Mine Road 17 rue du Petit Albi−BP 8244 − Nevada City, CA 95945 95801 Cergy Pontoise Cergy, France TBMS Weiterstadt, Germany TBMS Brunnenweg 9 10 Presidential Way, 3rd Floor, Suite 300 D−64331 Weiterstadt, Germany Woburn, MA 08101
TBMS TBMS 15655 SW Greystone Ct. 2300 South Decker Lake Blvd. Beaverton, OR97006 Salt Lake City, UT 84119
TBMS TBMS −PCB Nederland B.V. Rennes, France 4800 RP BREDA Rue du Clos Courtel The Nederlands Cesson−Sevigne, Cedex France
TBMS/Nextream TBMS/Nextream Rennes, France Technopole Brest Iroise Rue du Clos Courtel CS 73808 Cesson−Sevigne, Cedex 29238 Brest Cedex 3 France France
Scope:The design, manufacture and support of video hardware and software products and related systems.
This Certificate is valid until: June 14, 2006 September 9, 2003 Renewal Date: June 14, 2003 Issued for the first time:
Revision Date:
H. Pierre Sallé President KEMA−Registered Quality, Inc.
The method of operation for quality certification is defined in the KRQ General Terms and Conditions for Quality Certification. Integral publication of this certificate and adjoining reports is allowed.
KEMA−Registered Quality 4377 County Line Road, Suite 202 Chalfont, PA 18914 Ph: (215) 997−4519 Fax: (215) 997−3809
xxxiv CM 4000 Installation and Operating Manual
June 14, 2000

JupiterXPress Jupiter AccuSwitch
INSTALLATION AND OPERATING MANUAL


Apex, Concerto,2 GS 400, Trinix, or
For jumper and switch setting information, re-
fer to the installation manual supplied with
ÏÏ ÏÏ ÏÏ Ï ÏÏ Ï ÏÏ ÏÏ Ï ÏÏ ÏÏ Ï Ï
the router.
Media con- verter or Hub 10base2 LAN
House SMPTE time code required
House sync required for vertical inter- val switching.
1 See page 2−13 for details.
2 Concerto requires Crosspoint Bus Adapter and CRS−MC−C2 Controller Board.

Figure 1−1. CM 4000/JupiterXPress Installation Overview.
Ï ÏÏ ÏÏÏ ÏÏ
Ï ÏÏ Ï ÏÏ ÏÏ Ï ÏÏ ÏÏ Ï ÏÏ Ï

The CM 4000 Jupiter Control System is designed to control Grass Valley Crosspoint Bus* and certain other matrix routers; video equipment using Sony remote control protocol; and certain other RS−422 devices. The devices to be operated are con- nected to the CM 4000, which is in turn connected to Jupiter control panels. The CM 4000 is configured using the Jupiter file server* (Figure 1−1).
Present Jupiter systems may include CM 4000, VM 3000, and/or SI 3000 System Controllers. The VM 3000 and SI 3000 are described in a separate manual.
The CM 4000 System Controller provides a hardware platform for the JupiterXPress or AccuSwitch applications. Note that only one of these applications can be downloaded and executed in a single CM 4000 at one time.
The following overview of system functionality applies generally to a CM 4000 controller running the JupiterXPress applica- tion. The AccuSwitch application supports a reduced set of functions (as described in the software package table).
An example JupiterXPress system is shown in Figure 1−1.
*Terms marked with an asterisk are defined in Glossary at the back of the manual.
Introduction

Grass Valley matrix routers that can be controlled by the CM 4000 include Apex, Concerto, Trinix, and Venus. The crosspoint bus* of the switcher is connected to a CM 4000; this in turn is connected to the Jupiter file server. Triton switchers can be controlled using a serial connection.
Pathfinding provides the user with the means to communicate between routing switchers, including automatic standards con- version when switching between analog and digital routers.
The CM 4000 can optionally support several third−party matrix router protocols. Multiple routers with different protocols can be mixed in one system if desired. For a list of supported remote routers, please refer to page 1−28.
The CM 4000 is specifically designed to provide all configuration and control interface functions required for full integration with a Saturn Master Control Switcher. Integration with tally/UMD products varies with equipment used (see page 1−30).
Each Sony−protocol device using the basic RS−422 control scheme requires one dedicated port of a CM 4000.
These protocols can be used by external computers and automation systems to send switch messages into the Jupiter Control System. One serial port is used for each device.
For a list of supported protocols, please refer to page 1−28.
Detailed descriptions of these protocols are available. Please contact Grass Valley for more information.
Introduction

Jupiter message−per−keystroke (MPK) control panels are designed to be as simple, flexible, and inexpensive as possible. Sys- tem software is maintained in a central file server from where it is downloaded to the control processors as required.
Control panels are connected to the controlled device through the CM 4000 System Controller, using either the multi−point or single−point method.
For information beyond that given in the following summary, please refer to the control panel model number in the Index.
The CP 300 one−rack unit series includes the CP 300 24 x 1 Single Bus Control Panel; the CP 310 24 x 8 Eight Bus Control Panel; the CP 320 full−matrix, 16−category panel with a dedicated protect key; and the CP 330 Control Panel. The CP 330 can be configured as a 48 x 1, 24 x 2, or 48 x 6 panel. The CP 328 is similar to the CP 320 but has eight−character display windows.
The CP 2002 uses 16 LCD back−lit buttons that allow source mnemonics to be displayed in the button frame. The panel allows operators to select up to 256 sources by scrolling to additional pages. The colors of the buttons change to indicate the active source.
The CP 3000 switcher control panel can be configured for single−bus control (allowing selection of a source for one destina- tion), multi−bus control, or full matrix control (selection of a source for any destination). The CP 3000 panel is used to select one of 20 source categories (VTR, CAM, etc.) and then, using a 10−key pad, a unit within the category. Crosspoint status* is provided by the display window. Additional push buttons provide breakaway (control of individual switcher levels such as left audio, time code, etc), chop,* lock,* protect,* and override* switching. A password can be assigned to the panel if desired. The CP 3000 can also be operated in connection with an adjacent CP 3010 expansion panel. For example, for multi− bus control, the desired source can be selected on the CP 3000; the CP 3010 would then display the names of eight destinations, beneath which are eight corresponding TAKE keys; one of these would be pressed to complete the switch. The page of eight destinations can be scrolled to display up to 160 possible destinations.
The CP 3020 is a single bus control panel that can select one of 20 inputs. The push buttons illuminate to indicate status and can be fitted with user−supplied transparent labels. Dedicated chop and lock buttons are included. Up to four CP 3021 Push button Expansion panels can be added to the CP 3020, allowing button−per−input selection of up to 100 inputs.
The CP 3800 is a universal, eight−character mnemonic, switcher and machine control panel. When operated in the “multiple destination mode,” the CP 3800 can be used to control from 1 to 80 destinations, with the names of eight of those destinations (and the status for each) on display simultaneously. In the “single destination mode,” one destination is selected for control, and the display window shows the status for each level of that destination (video, left audio, right audio, etc.).
The CP 3808 control panel is a 16−category, full−matrix, multiple level breakaway panel capable of locking and protecting outputs. The CP 3830 is a 12−category, full−matrix, multiple−level breakaway panel, capable of locking, protecting, and chopping outputs. Dual CP 3830 panels can be configured so that one of the panels is always used for destination selection; dual output mode is also possible with two panels side by side. Both the CP 3808 and CP 3830 can be operated in connection with an adjacent CP 3809 Expansion Panel. All three panels feature eight−character display capability and relegendable, lighted push buttons.
Introduction

The CP 3824 control panel is a locally−programmable, full−matrix, multiple level breakaway panel capable of locking and protecting outputs. The panel features eight−character display capability and relegendable, lighted push buttons. The 24 but- ton−per−source keys on the left side of the panel are initially assigned to inputs from the file server, but some or all can be re−assigned to new inputs at any time using only the panel itself. Sources can also be selected by scrolling up or down an LED display of “Preset” mnemonics or by using the Category/Number keypad.
The CP 3832 is a button−per−source panel configurable for 32 X 1 or 16 X 16 operation. The panel includes buttons for TAKE, LOCK, and PROTECT. The CP 3864 is a button−per−source panel configurable for 64 X 1 or 32 X 32 operation and includes buttons for TAKE, LOCK, PROTECT, and CHOP. Both panels can be grouped with additional CP 3832s or a CP 3864 to provide up to 128 X 128 control. The CP 3810 expansion panel can be associated with a CP 3832, CP 3864, CP 3808, or CP 3830, providing control of up to 80 outputs. The CP 3810 can be operated as a status display only (no control) for one output, and as a limited−function machine control panel providing Play and Stop commands for VTRs.
The MC 3000 machine control panel, which is capable of operating any of the machines described above, includes a series of push buttons for motion control (PLAY, STOP, etc.). A variable speed knob, with a color−coded direction/speed indicator, is included. When used with a serial control VTR, the panel provides a continuous display of the machine’s time code. Also available is the MC 3010 machine control panel, which includes a gang−start function and illuminating push buttons.
The following machine assignment systems are available:
The CP 3800 and Software Control Panel Suite (described below) are also available for machine control applications.
The Software Control Panel Suite (“Graphical User Interface”) consists of seven routing switcher and machine control ap- plications plus a configuration application. Only one of the applications can be activated at a time.
The software operates on a PC using the Jupiter Network Suite (JNS) software, which provides the interface to the Jupiter Control system through the Jupiter LAN. The Software Control Panels are designed for mouse or touchscreen operation.§
The panels can be run on the Jupiter file server, on one or more separate PCs on the Jupiter LAN, or on both.
Using the MI 3040 General Purpose / Tally Interface, the Jupiter system can follow a source, such as a camera or VTR, through as many as five switchers and turn on the tally light next to the source when it is switched to air. Switchers that are on−air can also be tallied. Multiple sources will be tallied simultaneously during keys, special effects, etc.
§ For touchscreen operation, the PC and monitor must be supplied by Grass Valley.
Introduction

The Grass Valley SlimLine UMDs combine status and tally functions in the same chassis and are available in a wide range of sizes and types. SlimLine UMDs are described on page 2−81.
Certain third−party UMDs are also compatible with Jupiter equipment. See page 1−30.
The CM 4000 / JupiterXPress product provides a VGA output for system status display, with basic controls located on the front panel. The VGA output is designed to give a great deal of flexibility to the user in defining what kind of system informa- tion will be displayed at a particular location on the VGA screen. The types of information, or “fields,” that can be displayed are:
Switcher Output Status (any level) Switcher Input Status (any level) Machine Status (Play, Stop, Record, etc.) Machine Delegation Status Machine Linkage Status (Which control panel it’s currently linked to) System Time and Date System Control Board Status (Active, Inactive) System Control Board Time Source (Time Code Reader, File Server, etc.) System Control Board Messages (Also displayed by the logger) Pathfinding (Tie Line) Status
The type and location of these fields are determined by a user−entered DOS ASCII text file.
Introduction

The PC 3000 File Server supplied by Grass Valley is described in detail on page 1−14.
When the system is initialized, program information is downloaded from the file server to the control processor(s). Field up- grades and modifications can thus be made through this single station.
Provides the user with system status display in a window on the Jupiter file server or Jupiter remote PC.
Microsoft Windows−style menus are used to configure the various components of the system. For example, these menus are used to set the individual buses of the CM 4000 to MPK, Sony, or other protocols as needed.
Introduction

CM 4000 CONTROL MODULE
Front panel controls:
Front panel indicators:
Power supply status (+3 V, +/−5 V, +/−12 V) Active System status (7−segment LED)
1, Probe (diagnostic) (9−pin D female)
1, Video Out (VGA) (15−pin HD female) 1, SMPTE Time Code In (XLR female) 1, Sync (reference), 1 V P−P to 4 V P−P, looping (BNC) 1, Alarm (SMPTE 269M−1999) 8, Serial Ports (RS−422/ESbus) (9−pin D female)†
1, Redundant (control) (15−pin D female) 1, Grass Valley router Crosspoint (XPT) bus, looping (15−pin D female) 2, Aux (not implemented) 1, LAN (10/100baseT) (RJ−45) 2, USB (not implemented)
† See page 2−12 for restrictions on use of these ports for “remote” (serial) switcher control.
Introduction · Front panel connectors · Rear panel connectors

LAN1
AUX 1
AUX 2
REDUNDANCY
XPT BUS VGA
SERIAL 7
SERIAL 8
SERIAL 5
SERIAL 6
SERIAL 1 SERIAL 3
SERIAL 4
UP NEXT SELECT
SERIAL 2
DOWN RESET ACTIVATE +3V
SYNC ALARM
TIMECODE IN
+5V
−5V
+12V
−12V
100−240V 50−60HZ .4A
Figure 1−2. CM 4000.
Introduction · Front cover removed

Protocols supported: Please refer to software package table beginning on page 1−27.
No. of tributaries (devices) per bus: 1−32, depending on speed requirements
Protocols supported:
Super crosspoint bus, Grass Valley binary
Cable/connectors: 10−conductor twisted pair plus ground / 15−pin D Transmission speed: 1 Mbit/sec (approx) Routers supported:
Apex Concerto (with CRS−MC−C2 Controller Module) GS 400 Mars SDR 400 Trinix TVS/TAS 1000 (through CE−1003B) TVS/TAS 2000 TVS/TAS 2001 TVS/TAS 3000 Venus
Serial control routers include Triton and certain third−party routers. See page 1−28.
Introduction

CP 300/310/320/328/330 Control Panels
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female)
Power requirements: +5VDC +/− 0.25V @ 600 mA. A wall plug−in power supply is supplied with each 300 series panel that will be used with 110 VAC 60 Hz power. Panels that are to be used in areas where 220VAC 50Hz power is the norm are not shipped with any power supply. See page 2−38 for more information.
CP 2002 series control panels
Connectors:
1, MPK (RS−485), looping (RJ45) 1, DC in, Molex Mini−Fit, Jr., 2−pin Power requirements: 9 VDC / 1.5 A. Use only brick−type power supply, order no. 006 022 811 001 (Euro−plug) or
006 022 811 002 (USA plug)
CP 3000 switcher control panel, MC 3000/3010 machine control panel
CP 3010 expansion panel
Connections to main panel (CP 3000 or MC 3000): flat wire bus Power requirements: +5 VDC§
CP 3020, VC 3020 Push Button Control Panels
Connectors:
1, Data A (RS−422/ESbus), looping (9−pin D female) 1, Remote (for expansion panel) (37−pin D female) Power requirements: 117/220 VAC, 0.25/0.125 A
CP 3021 Push Button Expansion Panel
Connectors:
1, Input (from CP/MC/VC 3020 main panel) (37−pin D female) 1, Output (to next CP 3021) (37−pin D female) Power requirements: powered from main panel Max no. of CP 3021 per main panel: 4
CP 3800 Control Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female) Power requirements: 117/220 VAC, 0.25/0.125 A
§ Furnished by CP 3000/3010 chassis power supply. Power supply requirements: 117/220 VAC, 0.5 /0.25 A.
Introduction

CP 3830 Control Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female) Power requirements: power furnished by control panel chassis power supply.***
CP 3808 Control Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female) Power requirements: power furnished by control panel chassis power supply.§
CP 3809 Expansion Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female) Power requirements: power furnished by control panel chassis power supply.§
CP 3824/3832/3864/3810 Control Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female) Power requirements: 110/250 VAC, 0.8/0.4 A; 47−63 Hz.
Standard displays (screw mount):
Connectors: 1, RJ45 female jack for connection to SlimLine Controller Power requirements: Single Display, 9 W; Dual Display, 18 W; Universal Display, 30 W. 24 VDC power
supplied by SlimLine Controller Operating temperature: minus 10 to plus 50 degrees C
OB van displays (hinged plate mount):
Connectors: 1, 4 m flat cable with RJ45 male plug for connection to SlimLine controller Power requirements: same as Standard display Operating temperature: minus 10 to plus 50 degrees C
Controller and Power Supply:
16, RJ45 female jack for connection to displays 1, 9−pin D female jack, looping, for RS−422 MPK connection to CM 4000. Alternatively used for software download and diagnostics Supply voltage 88−264 VAC, 47−63 Hz Fuse: 2A (230V), 4A (115V). Inrush current: 3.6 A. Maximum output power: 240 W Operating temperature: minus 10 to plus 50 degrees C
§ CP 3808/3809/3830 chassis power supply requirements: 85−264 V, 47−63 Hz. (0.8 A @ 100 V, typical; 0.4 A @
200 V, typical.)
Introduction

Grass Valley PC 3000 System File Server
PC 3000 Specifications (Minimum)
Intel Pentium 700 processor with 256 K L2 cache 512 Mbytes RAM memory 1.2 Gigabyte hard drive 4X CD−ROM drive 1.44 Mb floppy drive Intel or 3Com Ethernet LAN card Keyboard / mouse 15−inch monitor capable of 1024x768x256 2 serial ports and 1 parallel port Windows 2000 Professional or XP Professional
A Site License is required to enable features; see Ordering Information (page 1−22).
Jupiter software is installed and tested.
Use of a customer−supplied computer is discouraged (to avoid compatibility problems due to evolving software require- ments). If circumstances require a customer−supplied computer, please contact Grass Valley Technical Support.
CM 4000 SYSTEM CONTROLLER
1.75 in. high x 19 in. wide x approx. 17 in. deep (44 x 483 x 432 mm)
1.75 in. high x 19 in. wide x 16.75 in. deep (44 x 483 x 425 mm)
CP 2002 series panels: 1.75 in. high x 19 in. wide x approx. 8 in. deep (44 x 483 x 201 mm). (Design allows chassis sections to be separated when depth is critical—contact Grass Valley for more information.)
The CP 3000, CP 3010 expansion, and MC 3000/3010 panels are normally mounted in a chassis which is 3.5 in. high x 19 in. wide by 7.5 in. deep (89 x 483 x 190 mm). The chassis has space for two panels; a blank insert is provided when required. (For custom mounting information, see page 1−15.)
CP 3020, VC 3020 Push Button Control Panels: 1.75 in. high x 19 in. wide x 10 in. deep (44 x 483 x 254 mm). CP−3021 and CP−300 Series: 1.75 in. high x 19 in. wide x 3 in. deep (44 x 483 x 75 mm).
Introduction

CP 3800 Control Panel: 3.5 in. high x 19 in. wide x approx. 8 in. deep (89 x 483 x 200 mm).
The CP 3808, CP 3809, and CP 3830 panels are mounted in a chassis which is 3.5 in. high x 19 in. wide by 4 in. deep (89 x 483 x 100 mm). The chassis has space for two panels; a blank insert is provided when required.
CP 3824 Control Panel: 1.75 in. high x 19 in. wide x approx. 6 in. deep (89 x 483 x 152 mm).
CP 3832 and CP 3810 panels: 1.75 in. high x 19 in. wide by 4 in. deep 44 x 483 x 100 mm). CP−3864: 3.5 in. high x 19 in. wide by 4 in. deep 89 x 483 x 100 mm).
Displays − Standard (screw mount) type
UMD 9 SD: 1.75 in. high x 9 in. wide§ x 1.15 in. deep (44 x 228 x 29.2 mm), 0.66 lb. (0.30 kg) UMD12 SD: 1.75 in. high x 12 in. wide§ x 1.15 in. deep (44 x 302 x 29.2 mm), 0.71 lb. (0.32 kg) UMD 14 SD: 1.75 in. high x 14 in. wide§ x 1.15 in. deep (44 x 335 x 29.2 mm), 0.73 lb. (0.33 kg) UMD 19 SD: 1.75 in. high x 19 in. wide x 1.15 in. deep (44 x 483 x 29.2 mm), 0.93 lb. (0.42 kg) UMD 19 DD: 1.75 in. high x 19 in. wide x 1.15 in. deep (44 x 483 x 29.2 mm), 1.46 lb. (0.66 kg) UMD 19 UD: 19 1.75 in. high x 19 in. wide x 1.15 in. deep (44 x 483 x 29.2 mm), 1.5 lb. (0.68 kg)
§Width of front of panel. For custom−mount cut−out dimensions refer to SlimLine manual.
Displays − OB (hinged plate mount) type
UMD 9 SD OB: 1.75 in. high x 8.66 in. wide x 0.87 in. deep (44 x 220 x 22.2 mm), 1.2 lb. (0.54 kg) incl. mounting plate UMD 12 SD OB: 1.75 in. high x 12 in. wide x 0.87 in. deep (44 x 302 x 22.2 mm), 1.3 lb. (0.57 kg) incl. mounting plate UMD 14 SD OB: 1.75 in. high x 14 in. wide x 0.87 in. deep (44 x 335 x 22.2 mm), 1.3 lb. (0.58 kg) incl. mounting plate UMD 19 SD OB: 1.75 in. high x 17.4 in. wide x 0.87 in. deep (44 x 442 x 22.2 mm), 1.5 lb. (0.66 kg) incl. mounting plate UMD 19 DD OB: 1.75 in. high x 17.4 in. wide x 0.87 in. deep (44 x 442 x 22.2 mm), 2.4 lb. (1.08 kg) incl. mounting plate UMD 19 UD OB: 1.75 in. high x 19 in. wide x 0.87 in. deep (44 x 483 x 22.2 mm), 2.4 lb. (1.11 kg) incl. mounting plate
Controller: 3.5 in. high x 19 in. wide x 0.9 in. deep (88.9 x 483 x 23 mm).
Dimensions are typical for a desktop PC. For exact measurements of file server currently supplied with Jupiter systems, please contact Grass Valley.
The CP 3000 Router Control Panel, MC 3000 Machine Control Panel, CP 3010 expansion panel, and MC 3010 Single 4 Ma- chine Control Panel are available without chassis or power supply (See page 1−22 for part numbers). Each individual panel measures 80 mm high (exactly) x 200 mm wide (exactly) x 65 mm deep (approx.) or approx. 3.2 x 7.9 x 2.5 inches. The panels are designed to be fastened along the top and bottom front edges (reference: Grass Valley drawing no. 10−040151−001). The power supply normally supplied is a 5 volt 3 amp Volgen ES−05003, Grass Valley part no. 06−033098−002. The connector used for connecting the power supply cable to the panel’s PC board is Grass Valley part no. 30−036841−004.
Introduction

Maximum Number of Logical Levels
The system−wide maximum number of logical levels is 96. However, the actual number of levels a CM 4000 can control in a particular system varies.
The main constraint on the number of levels and outputs a CM 4000 can safely control is the available memory in PMEM, or backed−up permanent memory. When a CM 4000 starts up, the old status tables are used to generate a completely new set of status tables. Therefore, no more that half of the total available memory may be used to store switcher status. The CM 4000 has 512 Kb of PMEM available. That means that no more than 262,144 bytes may be used for router status tables.
This formula for router status table PMEM memory usage is based on the worst−case scenario. It assumes that every physical output on every logical level in the system has its own unique entry in a Switcher Output Table. The formula for each CM 4000 in the system is:
(14 x TL) + (6 x TL x PO) + (10 x PO) + 600 < 262,144
PO = the total number of physical outputs on ALL levels controlled by this CM 4000
This total must be less than 262,144. For example, in Figure 2−1 a 25−level switcher can have up to 64 outputs per level.

(14x25) + (6x25 x {64x25}) + (10 x {64x25}) + 600 = 256,950
10 15 20 25
64 128 256 172
Figure 2−1.
It is easy to see that if the logical levels in the Jupiter system consist of small routers with few outputs per logical level, more of these levels can be controlled by a single CM 4000. However, if the Jupiter system consists of larger routers, fewer of these levels can be controlled by a single CM 4000, and the system’s router control must be “broken up,” or distributed among multi- ple CM 4000s.
Introduction

Versions of Jupiter prior to 5.1.0 will not handle edit sets which have more than 64 levels. Should you attempt to edit such a set, the Jupiter Configurator (editor) will detect the error in the Switcher Description table and will not run correctly. Another symptom is that the Configurator will not exit properly. (If you mistakenly do edit a set with more than 64 levels with a pre 5.1.0 version of Jupiter, terminate the Configurator, delete the invalid set from the YourJupiterDirectory\Config directory, delete the YourJupiterDirectory\Config\ics_conf file, and re−execute the Configurator.)
CP 38xx Control Panel
If you intend to control more than 64 levels from a CP 38xx panel, a control panel firmware upgrade will need to be ordered from the factory.
Recommendations for maximum number of devices per bus and processor board
The following guidelines can be used during system planning or as a part of a troubleshooting process. In the case of an installed system, a existing configuration set can be analyzed automatically using the “loading.exe” program available at the Support/FAQ web site.
The following are the base load factors for the specified devices and are subject to the multiplier described under “Calculating Loading” on page 1−18:
— Each CP 3800 Control Panel counts as four devices, with no more than two CP 3800 panels per controller
port.
— Each MC 3000 Machine Control Panel counts as four devices, with no more than 16 occurrences of MC 3000s
system−wide due to the amount of tape time code being processed.
— Each MC 3010 Machine Control Panel counts as one device: This number remains the same even for an MC
3010/2 Dual 4−Machine Panel.
— Each CP 300 Series Control Panel, CP 3000 Switcher Control Panel, and CP 3020 Push Button Control Panel
counts as one device.
— Each CP 3808 Control Panel, CP 3824 Control Panel, and CP 3830 Control Panel counts as one device. CP
3809 Expansion Panels count as two devices. For example, a CP 3808 with a CP 3809 Expansion Panel would count as three devices.
— Each CP 3832 Control Panel, CP 3864 Control Panel, and CP 3810 Expansion Panel counts as one device.
For example, a CP 3832 with a CP 3810 Expansion Panel would count as two devices.
— Each VC−3020 Video Display Control Panel counts as one device.
— Each Under Monitor Display counts as one−half a device.
— CP 3010 Expansion Panels and CP 3021 Push Button Expansion Panels are not counted.
Introduction · Base Load Factors

— Each CP 2002B/D Control Panel counts as four devices; therefore, a maximum of 16 can be connected to a
CM 4000 (two per serial port).
The following load factors are fixed and are not subject to the multiplier described below under “Calculating Loading”:
— If a CM 4000’s Crosspoint Bus is in use, it counts as twenty devices on that CM 4000.
— Each instance of a “remote” (non−Crosspoint Bus) switcher protocol counts as eight devices (maximum
one protocol per port).
— Each instance of the ASCII protocol counts as eight devices (maximum one protocol per port).
— Each instance of ESswitch counts as follows:
If the switch rate is less than fifty switches per second sustained past five seconds, that instance counts as eight devices (maximum one protocol per port). A switch is defined as a take from one input to one output on one level.
If the switch rate is more than fifty switches per second sustained past five seconds, that instance counts as 32 devices (maximum one protocol per port). A switch is defined as a take from one input to one output on one level.
— Each instance of serial machine control (Sony machine) counts as eight devices (maximum one protocol per
port).
— A maximum of sixteen devices may be assigned to an addressable controller port.
— Only one Sony−protocol device can be connected per port. Only one ASCII protocol device or ESswitch de-
vice can be connected per port.
— In order to calculate loading and quantity of processors required, the following steps should be followed:
Introduction · Fixed Load Factors · Calculating Loading

Note: The base multiplier is based upon the sum of the device counts of all devices system wide, NOT upon the devices on any single processor board. Therefore, if the sum of the device counts is 400 system wide, you must use a base multiplier of 2.0 when configuring the system. You can not merely sum the devices connected to each individual processor using a base multiplier of 1.0 and keep this sum under the specified maximum loading.
Introduction

A system is to contain the following:
2 channels of Saturn (1 DVP, 2 DAPs per channel). (Saturn Video and Audio Processors do not directly contribute to Jupiter loading) 1 Saturn MCC 3500 Master Control Console with the Select panel used for delegation pur- poses. (Saturn MCC 3500 panels do not directly contribute to Jupiter loading unless the Select panel is used with a backup switcher) 1 Saturn DVE (Sony serial machine protocol) Venus router control 1 Triton remote router control 8 MC 3000 Machine Control panels 16 serial machines 1 ASCII 1 ESswitch (high switch rate) 30 CP 328 Control Panels 16 CP 3800 Control Panels 4 CP 3808 Control Panels
ÁÁÁÁ
ÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁ

Since the sum of the base and fixed load factors of all devices in the system is greater than or equal to 320, this would be considered a heavily loaded system. Therefore, the indicated Base Multiplier (BM) would be 2.
One possible configuration of this system might then be:
ÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ

30 x 1 (BLF2) x 2 (BM3)
ÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ
Introduction · Example

ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁ
1Fixed Loading Factor 2Base Loading Factor 3Base Multiplier
Introduction

JUP−CM 4000 System Controller (software not included) 071 1276 00
JUP−PC 3000 System File Server (desk mount) F7-029500-121
PC workstation with LAN card for storing, editing and compiling system configurations. Also used for logging and diagnostics. Site license is required to enable fea- tures, order SW 2500 or SW 3100.
JUP−SW 3500 JupiterXPress Software F7-029500−158
JUP−CB 3000B Control Buffer Module F7-029500-508
Required for very large matrices utilizing over 96 boards on the crosspoint bus. Provides eight additional cross- point bus outputs. 1 RU. 110/220 VAC.
Control System Serial Data Cables for MPK bus and RS-232/RS-422 applications.
JUP−CNTLRTRBTYES-Bus Controller/Tributary Adapter Cable 01-041420-001 JUP−SRLDCBL 1 MPK Serial Cable 1 m 01-048591-001 JUP−SRLDCBL 2 MPK Serial Cable 2 m 01-048591-002 JUP−SRLDCBL 4 MPK Serial Cable 4 m 01-048591-004 JUP−SRLDCBL 8 MPK Serial Cable 8 m 01-048591-008 JUP−SRLDCBL 16 MPK Serial Cable 16 m 01-048591-016 JUP−SRLDCBL 32 MPK Serial Cable 32 m 01-048591-032 JUP−C-PCC2 PC to CE Configuration Cable for CE 300 and SC 400 01-044827-001
JUP−CC 2010 Matrix Cable See page 2−4
Introduction · Crosspoint bus cable

UMD−SD/9 Single Display UMD, 9−1/2 inch width 0 924 601 660 UMD−SD/12 Single Display UMD, 12 inch width 0 924 601 661 UMD−SD/14 Single Display UMD, 14 inch width 0 924 601 662 UMD−SD/19 Single Display UMD, 19 inch rack mount 0 924 601 663 UMD−DD/19 Dual Display UMD, 19 inch rack mount 0 924 601 665 UMD−UD/19 Universal Display UMD, 19 inch width 0 924 601 667 UMD−SD/9 OB Single Display OB van UMD, 9−1/2 inch width 0 924 601 680 UMD−SD/12 OB Single Display OB van UMD, 12 inch width 0 924 601 681 UMD−SD/14 OB Single Display OB van UMD, 14 inch width 0 924 601 682 UMD−SD/19 OB Single Display OB van UMD, 19 inch width 0 924 601 683 UMD−DD/19 OB Dual Display OB van UMD, 19 inch width 0 924 601 685 UMD−UD/19 OB Universal Display OB van UMD, 19 inch width 0 924 601 687 UMD−CTRL/16 UMD Controller, supplies 16 UMDs, 19 inch rack mount 0 924 601 690
JUP−31-5271 Amphenol Velcro Boot 05-042549-001
JUP−CP 300 24 x 1 Single Bus Control Panel F7-023600-001 JUP−CP 310 24 x 8 Eight Bus Control Panel F7-023600-002 JUP−CP 320 Control Panel F7-023600-003 JUP−CP 330 48 x 1 Single Bus Control Panel F7-023600-004
JUP−CP 2002D 16 soft-labelled LCD button control panel. Requires F7-971310-010 PSU CP EURO or PSU CP USA power supply
JUP−CP 3000 Switcher Control Panel F7-029500-021 JUP−CP 3000 Control Panel w/o Chassis or Power Supply F7-029500-005 JUP−CP 3000/2 Dual Control Panel F7-029500-025 JUP−CP 3000/E Switcher Control/Expansion Panel F7-029500-022 JUP−CP 3000RBK Relegendable Button Kit 44-046025-001 JUP−CP 3010 Expansion Panel without Chassis or Power Supply F7-029500-006 JUP−CP 3000/MC 3010 Switcher / Machine Control Panel F7-029500-048
JUP−CP 3020 Push Button Control Panel F7-029500-016 JUP−CP 3021 Push Button Expansion Panel (includes connecting cable) F7-029500-017
JUP−CP 3800 Control Panel F7-029500-058
JUP−CP 3808 Control Panel (without chassis) F7-029500-066 JUP−CP 3808/1 Single Control Panel (with chassis and blank panel) F7-029500-065 JUP−CP 3808/E Multi Control Panel (with CP 3809 Expansion Panel F7-029500-064 and chassis.) JUP−CP 3809 Expansion Panel (without chassis) F7-029500-069 JUP−CP 3809/1 Single Expansion Panel (with chassis and blank panel) F7-029500-068 JUP−CP 3809/2 Dual Expansion Panel (with chassis) F7-029500-067
JUP−CP 3810 Eight Character Eight Bus Expansion Panel F7-029500-082
Introduction

JUP−CP 3824 Eight Character Jupiter Plus X-Y Control Panel F7-029500-095
JUP−CP 3830 Control Panel (without chassis) F7-029500-063 JUP−CP 3830/1 Single Control Panel (with chassis and blank panel) F7-029500-062 JUP−CP 3830/2 Dual Control Panel (with chassis) F7-029500-061 JUP−CP 3830/E Multi Control Panel (with CP 3809 and chassis) F7-029500-076
JUP−CP 3832 Eight Character 32 Button Per Source Control Panel F7-029500-080 JUP−CP 3864 Eight Character 64 Button Per Source Control Panel F7-029500-078
JUP−CP/MC 3000 Switcher/Machine Control Panel F7-029500-024
JUP−GJ IC455B Black Box Interface/converter 05-040935-001
JUP−JEP 100 Jupiter / Encore Control Panel 610 1138 01
Manuals see page xxv JUP−MC 3000 Machine Control Panel F7-029500-020 JUP−MC 3000 Machine Control Panel without Chassis or Power Supply F7-029500-007 JUP−MC 3000/2 Dual Machine Control Panel F7-029500-026 JUP−MC 3000/E Machine Control with Expansion Panel F7-029500-023
JUP−MC 3010/1 Single 4 Machine Control Panel F7-029500-045 JUP−MC 3010/2 Dual 4 Machine Control Panel F7-029500-046 JUP−MC 3010 Single 4 Machine Control Panel without chassis or F7-029500-044 power supply
JUP−MC 3010/MC 3000 Machine Control Panel F7-029500-047
JUP−MC 3010 Expansion Control Panel (to convert MC 3010/1 to F7-029500-050 MC 3010/2)
JUP−PS 300 110/220 VAC Power Adaptor Kit. Adapts 300 series 44-046442-001 panel for direct connection to power mains.
JUP−PSU CP EURO Plug in Power Supply, Euro 220 V, for CP 2002 F6-022811−001 JUP−PSU CP USA Plug in Power Supply, USA 110 V, for CP 2002 F6-022811−002
Triton to Jupiter Serial Control Kit 44-050456-001
JUP−VC 3020 Video Display Control Panel Same as CP 3020
JUP−SW 31DT Datatek Matrix Control option F7−029500−107 JUP−SW 31UT Utah Scientific Control option F7−029500−111 JUP−SW3INXS Nexus Audio Router Driver Contact Grass Valley
Introduction

JUP−CM 4000 System Controller F7−029700−001
Software is not included. Required to run SW 4000 frame−accurate switching software.
JUP−CM 4000RDN Redundant Control Electronics (2 units) F7−029500−103
Software is not included. Runs SW 4000 frame−accurate switching software. Includes: Two CM 4000 units and one BOP 4000 Redundancy Cable Kit
JUP−BOP 4000 CM 4000 Redundancy cable kit and Break Out Panel F7−029500−104
Includes necessary cables for automatic changeover between two CMs
JUP−SW 4000 Software License F7−029500−124
For the frame−accurate switching software that runs on the CM 4000 control electronics. This license is for a single redundant pair of CM’s only. Additional licenses per additonal pars must be purchased. Key features are listed on page 1−27.
Introduction

JUP−PC−GUI/M GUI PC for Mouse control w/Basic X−Y Panels F7−029599−004
PC workstation with LAN card for operation of GUI control panels using a mouse. Includes the basic GUI− XY routing switcher control panel software.
JUP−PC−GUI/T GUI PC for Touchscreen Control w/Basic X−Y Panels F7−029599−085
PC with LAN card for operation of GUI control panels using a touchscreen. Includes the basic GUI−XY routing switcher control panel software.
JUP−GUI−XY Basic X−Y Soft Panels F7−029599−086
Includes two routing switcher control panels for mouse or touchscreen operation. The Basic X−Y panel imple- ments Category/Entry type operation using a single key- pad. The Source/Destination Panel provides separate keypads for faster operation. Requires PC. Order PC− GUI/M, PC−GUI/T or see minimum PC requirements on page 1−14.
JUP−GUI−SPCL Special GUI Soft Panels F7−029599−087
Includes three routing switcher GUI control panels for mouse or touchscreen operation. Dub panel switches a single source to multiple destinations. Salvo panel switches multiple source destination combinations with a single TAKE. Full Function X−Y panel provides breakaway capability and user−assignable buttons for direct access to commonly used sources. Requires PC. Order PC−GUI/M, PC−GUI/T or see minimum PC re- quirements on page 1−14.
JUP−GUI−MC Machine Control Soft Panels F7−029599−088
Includes two machine control GUI panels for mouse or touchscreen operation. The Full Function MC panel pro- vides basic transport functions plus jog, variable play and time code display. The Slaved MC panel provides six machine, six function control plus Gang command. Requires PC. Order PC GUI/M, PC GUI/T or see mini- mum PC requirements on page 1−14.
Introduction

Jupiter software is available in several software (SW) packages. One of these packages is normally activated by the end user with a unique key code during installation (as described in the Field Engineering Bulletin supplied with the software).
The key features of these packages are summarized in the following table. Please keep the differences between packages in mind when you refer to the instructions in this manual.
Figure 1−3. Key features of Jupiter software packages.

Controller type VM/SI 3000 VM/SI 3000 CM 4000 CM 4000 See Note 2
Multiple controllers in network Yes Yes Yes (see Note 3) Yes (see Note 4)
Yes See also page 1−11 for older Cross- point Bus routers supported
Maximum Inputs x Outputs 128 x 128 1024 x 1024 4096 x 4096 (using Ultra Crosspoint bus)
Path finding (tie−line management) Yes See Notes 6 and 7
Windows 95/98 Not supported Not supported Not supported Not supported
Windows NT Not supported Not supported Not supported Not supported
Introduction


GVG 1020 NVISION Sony Control Vistek Novotronic Microvideo VT−220 (Southbank)
Alpha Image Data Tek GVG Native (outgoing) Nexus Pro−bel Eclipse Utah 96
No Yes Yes (with Jupiter 7.4.1) Yes (with Jupiter 7.4.1)
Introduction


CP 3000 series All All No Yes, except CP 3008 and CP 3030
CP 3800 series All All No Yes, except CP 3810/S, CP 3830/P, CP 3832/P, and CP 3864/P
MC 3000 series No All No Yes, except MC 3020
Introduction


Software Control Panel Suite (GUI) Option
Image Video Tally/UMD Yes Yes Yes (ASCII) Yes (ASCII)
On screen status display No No Yes (Using GV 8964OMD OSD) No
JNS Control System User Apps Yes Yes Yes, except CP I/O, Saturn Follow and PL Download
1. For additional AccuSwitch information, see Appendix G. 2. JupiterXPress and AccuSwitch cannot be downloaded and executed in the same CM at the same time. 3. AccuSwitch cannot execute in a VM/SI but can operate in a network that includes a VM/SI. 4. JupiterXPress cannot execute in a VM/SI and cannot be operated in a network that includes a VM/SI. 5. Except for Triton, matrixes larger than 256 x 256 are an extra−cost option for serial control (“Remote”) routers. 6. Pathfinding is supported between CM−controlled routers provided that the CMs are running the same application (e.g. both are running JupiterXPress or both are running AccuSwitch). Pathfinding is not supported between a VM−controlled router and a CM− controlled router. 7. Data level pathfinding is not supported by any Jupiter system. 8. Only switches on routers directly connected to a CM running AccuSwitch can be guaranteed to be frame accurate. 9. Each “remote” router protocol is available as a separate option. 10. For the SlimLine UMD−UD/19, only the triple display mode is supported (i.e., 3 groups of 8 characters each).
Introduction

Unpacking and Inspection
Each Jupiter Control System is tested, inspected, and found free of defects prior to shipment. Before unpacking the equipment, inspect the shipping carton for evidence of freight damage. If the contents have been damaged, notify the carrier and Grass Valley. Retain all shipping cartons and padding material for inspection by the carrier.
Do not return damaged merchandise to Grass Valley until an appropriate claim has been filed with the carrier and a material return authorization number has been received from us.
Quick Start tip: If your Jupiter equipment was purchased from Grass Valley as a “turnkey” system, you may wish to refer to the Jupiter Getting Started Guide, part no. 04-045707-003. This booklet provides an abbreviated version of the information in this section.
Most panels are auto sensing; otherwise, power line adjustments are normally made at the factory, based on the location of the end−user. However, verifying these settings before applying power is a good practice.
These panels use an external power supply. See page 2−37.
Check to see if the PC file server supplied with the system has a voltage selector switch for the power supply on the rear panel, and if so, that the proper mains voltage is set.
Installation instructions for the file server begin on page 2−36.
Grass Valley recommends that each control chassis be near most of the devices which it will control, thus reducing system cabling. The CM 4000 Control Module should be located near the distribution switcher. See Figure 2−2 for the location of the chassis fan and ventilation openings.

Leaving ventilation space between the rack mount units is not necessary.
System diagrams are shown in the following pages.
Do not block fan opening
on side of chassis.
Figure 2−2.
Do not block ventilation holes.
Rack mount support must be cut shorter if
necessary to avoid blocking airflow.
Hardware Installation

Although the CM 4000 supports both the JupiterXPress and AccuSwitch applications, only one of these applications can be downloaded and executed in a single CM 4000 at one time.

Apex, Concerto§, GS 400, Trinix, or Venus router§§
For jumper and switch setting information, re-
fer to the installation manual supplied with
the router.
CRS−MC−C2 Controller Board. For more informa- tion, refer to Grass Valley Field Engineering Bulle- tin 075−0722−00, “Jupiter Crosspoint Bus Control of Concerto Flexframe Routing Matrix.”
House SMPTE time code required
House sync required for vertical inter- val switching.
§§ For a complete list of supported Crosspoint
Bus routers, see page 1−11.
Figure 2−3. Example of CM 4000 / JupiterXPress installation.
Hardware Installation · for deterministic · switching

The CC 2010 cable is used to connect the CM 4000 to the switcher Crosspoint Bus. Depending on the size of the switcher, this bus may require intermediate buffering through the CB 3000 Control Buffer. See Figure 2−3.
The CC 2010 is a 10−conductor (plus ground) cable. The following ready−made cables, with installed 15−pin D male connec- tors, are available from Grass Valley:
Length Part. No.
1 foot (0.3 m) 01−048592−001
2 feet (0.6 m) 01−048592−002
3 feet (0.9 m) 01−048592−003
10 feet (3 m) 01−048592−010
25 feet (7.6 m) 01−048592−025
50 feet (15.2 m) 01−048592−050
100 feet (30 m) 01−048592−100
Figure 2−4.
All rear−panel Crosspoint Bus connectors are 15−pin D, female. For Concerto and Trinix applications, the crosspoint bus must be terminated at the point farthest from the control processor using a Crosspoint Bus Terminator, part number 01−053050−001. For other routers, no termination is required.
For specific wiring instructions concerning CC 2010 Crosspoint Bus Cables, please refer to the installation diagrams supplied with your switcher.
For those who wish to prepare their own cables, pin−outs are shown in Figure 2−5. The cable itself should be Belden 9505 or equivalent. Steps should be taken to shield the connectors, e.g., using EMI housings or ferrite cores. Details concerning ferrite cores are given in Figure 2−7.
Hardware Installation

2 Yellow 10 Black
3 Green 11 Black
4 Blue 12 Black
5 White 13 Black
Shielded connector Shielded connector
100 ft ( m) max
Figure 2−5. CC 2010 wiring. Reference: “Assembly, XPT Bus Cable Shield,” Grass Valley drawing no. 01−048592−TAB.

SELECT
SELECT
A
OUTPUT (CONTROL)
B
B POWER
REM/ALM
A POWER
BUSES CROSSPOINT
BUS LOOP
Figure 2−6. CB 3000.
The CB 3000 Control Buffer is required for buffering crosspoint data when the system includes:
Each of the eight CB 3000 outputs can drive up to 50 (TVS/TAS) or up to 96 (Venus) crosspoint boards. See page 2−3.
For Trinix requirements, please refer to the “Planning” section of the Trinix Planning and Installation Manual.
Apex audio routers do not require a CB 3000—regardless of system expansion—because the crosspoint bus is connected only to one chassis.
A CB 3000 may also be needed if the system includes more than one router type (e.g., a Trinix and an Apex) and one of the routers is at or near the bus limit. For more information, contact Grass Valley.
Some systems may be equipped with one or more single−output CB 2000 Control Buffers rather than a CB 3000. Please refer to the wiring information supplied with your switcher for details.
Each CB 3000 output contains two identical channels, with channel A normally used; this condition is indicated by the eight green LEDs in the display window. If a fault is detected in channel A, that output will automatically switch to channel B; in this case the green LEDs would be off and one or more red LEDs would be on. If a changeover occurs, first check to see if the unit will return to normal operation by pressing the SELECT A button:
— If the unit returns to channel A operation, but a red LED remains on, press CLEAR. If the red LED(s) go off, it
can be assumed that the unit is fully operational.
— If the unit immediately returns to channel B operation, contact Grass Valley Technical Support.
For a description of the front panel window LEDs, see Appendix R.
Hardware Installation

User−supplied matrix cables for VDE installations require a ferrite core over each end of the cable, adjacent to the connector.
Type 43 material sources
Type 43 material 0.375 inch (9.53 mm) or larger inside diameter 0.95 inch (24.13 mm) length (or longer)
Fair−Rite, part no. 2643625102
Fair−Rite Products Corp., P.O. Box J, Commercial Row, Wallkill, NY 12589, USA; Tel. (914) 895−2055.
Chomerics, part no. 83−10−A637−1000
Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888 USA; Tel. (617) 935−4850.
Figure 2−7. Matrix cable VDE modifications.
The CM 4000 master alarm is asserted when:
The master alarm condition is indicated by a “00,” “01,” or “FF” indication on the front panel LED display, and at the rear panel Alarm BNC connector. Electrically, the Alarm BNC operates according to SMPTE standard 269M−1999. When an alarm is asserted, the circuit associated with the Alarm connector will present a low impedance to an external current source circuit provided by the customer. Figure 2−8 shows the CM alarm circuit (left) and an example of a customer−supplied indica- tor circuit (right).
EXTERNAL CIRCUIT
(EXAMPLE)
NOT TO EXCEED 24 VDC @ 20 mA
Figure 2−8.
Hardware Installation

If the master alarm is asserted by the main CPU watchdog timer (and assuming that the power supply is operating properly), the CM will be rebooted automatically.
For additional protection, a redundant (slave) CM 4000 can be installed. The slave CM 4000 monitors the master.
If a master alarm condition is detected in the master unit, control will be switched to the slave automatically. Switch over to the redundant unit is nearly instantaneous, providing minimal disruption to the control system. The controlling CM is indi- cated by a green light on the Activate button.
To manually change operation from the master to the slave, press the Activate button on the front panel of the slave unit. To return operation to the master, press the Activate button on the master unit.
Replacement of a Failed Redundant Unit
Protection can be further enhanced by maintaining a third CM as a “replacement” stand−by unit. This CM can be configured in advance with the same network address as the master. Should the master fail, and the slave assume control, the third CM would be installed on the network and the failed master removed; the operator could then manually switch control to the new master. This would restore the system to the original master plus slave backup arrangement and allow repair of the failed unit with no interruption in service. To prepare a third unit as a replacement in case of failure, please refer to Appendix K.
Installing Redundant CM 4000 Control Modules
In a dual CM system, the redundancy cable between the units is marked “Master” on one end; whichever CM is connected to this end of the cable is always the master unit.
Wiring for redundant CM 4000s is shown in Figure 2−9. The BOP 4000 Break Out Panel is designed to be mounted in the back of an equipment rack, behind the redundant CMs.
Hardware Installation · Manual Changeover


Hardware Installation

Rear of BOP 4000
2 ea. crosspoint bus cables
8 ea. serial control splitter cables
M
F
3 feet (0.91 m)
3 feet (0.91 m)
M
3 feet (0.91 m)
3 feet (0.91 m)
M
1 ea. Redundancy Cable
1.5 feet (0.46 m)
M
M
CM 4000
M = male connector
Figure 2−10. BOP 4000 and cables. Assembly no. F7-029500-104.
Hardware Installation · Master

Levels 1, 2, 6
Grass Valley Crosspoint Bus
CM 4000 System Controller
Figure 2−11. Connection to serial control routers (example).
House SMPTE time code required
House sync required for vertical inter- val switching.
The CM 4000 System Controller can be used to control certain non−Crosspoint Bus switchers using serial interface ports (Figure 2−11). Control of some of these routers is an extra−cost option; such routers are referred to as “remote” routers.§
A single CM 4000 can be used to operate one or more switchers through the Crosspoint Bus, while operating up to four sepa- rate “serial” switchers through the serial ports.
Please note the restrictions for this application shown in Figure 2−12.
The CM 4000 must be configured using the Network Description table (page 5−27); Serial Protocol table (page 5−30), and Switcher Description table (page 5−35).
Please refer to the following pages for details concerning each switcher type. The manual supplied with the switcher should also be checked for port configuration instructions.
§ For more information about Jupiter options, see page 1−27.

Figure 2−12. Serial−control switcher restrictions.
Only one remote switcher of a given type can be connected to a single CM 4000.
Grass Valley Crosspoint Bus
Physical levels cannot be duplicated on a CM 4000 (unless Logical Level Mapping [page 2−29] is used; or, the “400” offset method [footnote on page 5−42] is used).

Triton routers are connected using a CM 4000 serial port. Multiple Triton chassis can be connected to a single CM, but only if all them are connected on the same MIDI bus and connected through the same single serial port. If more than one Triton MIDI bus is needed, the switchers on that bus must be connected to another CM.
The serial connector on Triton routers is a 9−pin RS−232 signal level port. Since the CM has RS−422 ports, a RS−422 to RS−232 converter must be used to ensure reliable communications. Please refer to Figure 2−13.
Triton L + R Audio
See Figure 2−14 for
units). See Triton manual for details.
† A Triton−to−Jupiter Serial Control Kit
is available from Grass Valley. See text for details.
CM 4000 System Controller
Figure 2−13. Example of connection to Triton distribution switchers.
A Triton−to−Jupiter Serial Control Kit, available from Grass Valley, includes a B&B Electronics 422COR RS−232/RS−422 Converter, a B&B Universal Power Supply, a 25 ft. (7.6 m) VM/CM to Converter Cable, and a 5 ft. (7.6 m) Converter to Triton Cable. The part number of this kit is 44-050456-001.
Multiple Triton switchers are connected with a MIDI bus loop (as detailed in the Triton manual). In a typical video/audio switching application, each chassis is set with a unique “Router Address” from 0 to 15 (DIP switches 1−4 on the rear panel). Note that split switching is possible, but only between chassis; e.g., Audio Left/Right can be split from Video, but Audio Left cannot be split from Audio Right.
In RGB or YUV applications where all three signals must always switch together, the Router Address should be set to the same value on each chassis.

Up to 20 chassis can be connected in one MIDI loop.
In order for a Triton analog video router to switch on Vertical Interval as set in the Switcher Description Table, rear−panel DIP 7 must be DOWN and a sync reference signal must be connected to Input No. 1. The reference signal must be composite video, 1 Vpp, 300 mV sync, 75 ohms. For more information, refer to the Triton manual.
to CM serial port
to Triton RS−232 Port
G
R−
T−
R+
T+
T+ R+
T− 8
R−
5 G
RS−422/232
DB9P (male) = twisted pair
G Ground Rx Receive Tx Transmit
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
Figure 2−14. Cables for connecting CM 4000 to Triton RS−232 port.
The CM connected to the Triton router must be configured using the Network Description table (page 5−27) and Serial Proto- col table (page 5−30).
Triton configuration is similar to that for other routers, beginning with the Switcher Description table (page 5−35). From that point, switcher inputs, outputs, a CP Level Set, and CP input/Output Sets must be defined.

The CM 4000 can be connected to a Grass Valley SMS 7000 Signal Management System and router (see Figure 2−15). The protocol setting is: 38400 baud, 8 data bits, no parity, 1 stop bit.
The serial cable on the back of the SMS 7000 controller frame may be labeled RS−232, but it can and should function as RS−422 if configured in software. The CM 4000 is connected to one of the DB25 or DB9 ports on the back of the SMS 7000 controller frame. Refer to the manual supplied with the SMS 7000 for instructions on setting the port up for RS−422 and set- ting the serial parameters.
to Series 7000 routing switcher
SMS 7000 control system
See page 2−16 for a description of this cable
CM 4000 System Controller
code (optional).
Figure 2−15. Connection to SMS 7000 Control System.
See pg.
The CM 4000 connected to the SMS 7000 must be configured using the Network Description table (page 5−27) and Serial Protocol table (page 5−30).
The router must be defined on the Switcher Description table (page 5−35). From that point, switcher inputs, outputs, a CP Level Set, and CP input/Output Sets must be defined.

serial port to SMS 7000
R−
T−
R+
T+
T+
R+
T− 8
R−
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus DB9P (male)
Figure 2−16. Cable for connecting CM 4000 to SMS 7000 DB9 port.
R−
R+
R+
T+
T− 8
T−
R−
T+
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
Figure 2−17. Cables for connecting CM 4000 to SMS 7000 DB25 port.

The CM 4000 can send switching commands to a Grass Valley Encore control system (which can in turn send the commands to a router).
The serial ports on the back of the Encore System Controller Board (SCB) use RJ45 connectors; the port selected for the CM connection must be configured for RS−422 operation with an internal jumper. For more information about the SCB ports, refer to the Encore installation and user manuals.
See Figure 2−18.
CM 4000 System Controller
Figure 2−18. Connection to non−redundant Encore Control System. See following figures for cable variations.
code (optional).
See pg.
A Cat5 factory cable kit is available in two versions: If the SCB is the old style (071 0884 xx series), order kit 174 8216 xx. If the SCB is the new style (071 1000 xx series), order kit 174 8217 xx. The factory cable must be used with a customer−sup- plied adapter, wired as shown in Figure 2−19. Note that the factory cable is eight inches long. A customer−supplied standard Cat5 cable (and coupler) can be added if needed. Further instructions are provided with the cable kit.
To SCB RS−422 port
Figure 2−19. Factory−supplied Encore/Jupiter serial cable and customer−supplied items
8−inch cable supplied with Encore Y Cable Kit. (Type depends on SCB model; refer to text for ordering information.)
Standard Cat5 cable (max. 250 feet)
RJ45 female to 9−pin D male adapter at- taches directly to CM serial port. Internal wiring is per Figure 2−21.

For those who wish to prepare their own cable: if the SCB is the old style (071 0884 xx series), build the cable as shown in Figure 2−20; if the SCB is the new style (071 1000 xx), build the cable as shown in Figure 2−21. (No adapter is needed when the cable is custom−built).
G
G
Belden 8723 or equivalent
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground
Figure 2−20. Customer−supplied cable for connecting CM 4000 to old−style Encore SCB (061 0884 xx series).
= Shielded, twisted pair
G
G
G
G
RJ45P
Belden 8723 or equivalent
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground
Figure 2−21. Customer−supplied cable for con- necting CM 4000 to new−style Encore SCB (061 1000 xx series). These pinouts also apply to the cus- tomer−supplied adapter, if installed (refer to text).
= Shielded, twisted pair

The CM 4000 connected to the Encore must be configured using the Network Description table (page 5−27) and Serial Proto- col table (page 5−30).
When Jupiter is controlling Encore, the Serial protocol setting is: GNP (Grass Valley Native Protocol), 9600 baud.
The router must be defined on the Switcher Description table (page 5−35). From that point, switcher inputs, outputs, a CP Level Set, and CP input/Output Sets must be defined.
Some Encore systems may be equipped with redundant System Controller Boards (SCBs). In this case, the recommended arrangement is to install a redundant CM 4000 and connect the CMs to the SCBs with a BOP 4000 Break Out Panel. See Figure 2−22.
Figure 2−22. Connection to redundant Encore Control System. See following figures for cable variations.
BOP 4000 Break Out Panel
Serial Port Serial Port
Redundant CM 4000 System Controllers
Details of the Encore connection are presented below.

Please refer to Figure 2−23.
A Cat5 factory cable kit is available in two versions: If the SCB is the old style (071 0884 xx series), order kit 174 8216 xx. If the SCB is the new style (071 1000 xx series), order kit 174 8217 xx. The factory cable must be used with a customer−sup- plied adapter, wired as shown in Figure 2−21 on page 2−18. Note that the cables in this kit are eight inches long. Further instructions are provided with the cable kit.
The rack mount BOP 4000 Break Out Panel / cable kit is available for making Y connections to redundant CMs. For more information, see page 2−8 and following.
To SCB RS−422 ports
Figure 2−23. Factory−supplied Encore/Jupiter serial cables and customer−supplied items
8−inch cables supplied with Encore Y Cable Kit. (Type depends on SCB model; refer to text for ordering information.)
Standard Cat5 cable (max. 250 feet)
RJ45 female to 9−pin D male adapter. In- ternal wiring is per Figure 2−21.
BOP 4000 Break Out Panel
8 inches (203 mm)
8 inches (203 mm)
8−inch cables supplied with BOP 4000 Break Out Panel
To CM RS−422 port
To CM RS−422 port

For those who wish to prepare their own cable: if the SCB is the old style (071 0884 xx series), build the cable as shown in Figure 2−24; if the SCB is the new style (071 1000 xx), build the cable as shown in Figure 2−25.
G
G
RJ45P
G
G
G
RJ45P
(male) Belden 8723 or equivalent
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground = Shielded, twisted pair
Figure 2−24. Customer−supplied cable for connecting redundant CM 4000s to old−style redundant Encore SCBs (061 0884 xx series).

G
G
RJ45P
G
G
G
(male) Belden 8723 or equivalent
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground = Shielded, twisted pair
Figure 2−25. Customer−supplied cable for connecting redundant CM 4000s to new−style redundant Encore SCBs (061 1000 xx series).
Software Configuration (Redundant Systems)
Software configuration for redundant systems is much the same as that already described for non−redundant systems (page 2−19), except that two CM 4000s and two CM serial ports are configured.

The CM 4000 can be connected to a Horizon matrix router through the General Purpose Interface with Terminal/Computer Interface software (GPI−T/CI) (see Figure 2−26). The protocol for the GPI−T/CI RS−422 port must be set at: 38400 baud, 8 data bits, even parity, and 1 stop bit (refer to the Horizon GPI−T/CI Manual for configuration instructions).
See Figure 2−27 for a description of this cable
General Purpose Interface (GPI)
CM 4000 System Controller
code (optional).
Figure 2−26. Connection to Horizon matrix router.
See pg.
R−
T+
R+
T−
T+ R−
T− 8
R+
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus DB9P (male)
Figure 2−27. Cable for connecting CM 4000 to Horizon matrix router.

The CM 4000 can be connected to a Datatek D−2166 Buffer Control Module, which in turn is connected to a D−2000 Series routing switcher (see page 2−24). The protocol setting is: 38400 baud, 8 data bits, even parity, 1 stop bit.
Although the CM 4000 is connected to one of the D−2166 Buffer Control Module ports labelled “RS−232,” the port must be set with an internal jumper to operate according to RS−422. Refer to the manual supplied with the D−2166 for more infor- mation.
to D−2000 series routing switcher
D−2167 Buffer Interface and D−2166 Buffer Control Module in DF−2115 Rack Frame
See Figure 2−29 for a description of this cable
“RS−232−C A” or “RS−232−C B” port jumpered for RS−422 operation
CM 4000 System Controller
code (optional).
Figure 2−28. Connection to Datatek D−2166 Buffer Control Module.
See pg.
R−
T−
R+
T+
T+
R+
T− 8
R−
to Datatek D−2166/DF−2115 “RS−232−C A” or “RS−232−C B” port jumpered for RS−422 operation. Refer to the manual supplied with the Datatek
router for more information.
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
Figure 2−29. Cable for connecting CM 4000 to Datatek D−2166 Buffer Control Module.

The CM 4000 can be connected to a Utah Scientific Party Line through a UDI−1B Universal Data Interface (see Figure 2−30). Some UDI−1B units are equipped with a 9−pin RS−422 port; others are equipped with a 25−pin RS−232 port. Either type can be used.
The protocol for the UDI−1B port must be set at: 9600 baud, 7 data bits, even parity, and 2 stop bits. The UDI−1B must be equipped with software version 81.4 or later. The UDI−1B “AUX” rotary switch needs to be set to “E” for “PL−160 Mode” and to enable all mode commands. Refer to the UDI−1B manual for detailed procedures.
to Utah Scientific switcher
Utah Scientific Party Line
See Figure 2−31 for a description of this cable
See Figure 2−32 for a description of these cables
† If the RS−232 port is used it is advisable to use an RS−422 to
code (optional).
RS−232 converter. A Black Box model GJ−IC455B Inter- face/converter is available from Grass Valley; part no. 05−040935−001.
See pg.
Figure 2−30. Connection to Utah Scientific Party Line.

serial port UDI−1B RS−422 Port
G
R−
T+
T−
R+
T−
T+
T+ R−
R+
T− 8
R+
R−
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus DB9P (male)
DB9P (male) = twisted pair
UDI pinouts may vary − field reports
indicate that a straight−through
cable should be tried first.
Figure 2−31. Cable for connecting CM 4000 to UDI−1B RS−422 port.
G
G
R−
T−
R+
T+
T+ R+
T− 8
R−
RS−422/232
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
Figure 2−32. Cables for connecting CM 4000 to UDI−1B RS−232 port.

Nexus audio routers can be controlled using the hardware connections shown in Figure 2−33. The Nexus switcher requires special PROMs for this application (please contact Grass Valley for more information).
See Figure 2−34 or 2−35 for a description of this cable
code (optional).
Figure 2−33. Connection to Nexus audio router.
See pg.

The Nexus router has two ports that can be used for connection to Jupiter: the “XCI” port and the “XCPU” port. Field reports suggest that the XCI port be used if possible. The pinouts for both ports are shown below.
serial port to Nexus router XCI port
R−
R−
R+
R+
T+
T+
T− 8
T−
G
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus DB9P (male)
DB9
Figure 2−34. Cable for connecting CM 4000 to Nexus audio router XCI port.
serial port to Nexus router XCPU port
R+
R−
R+
R−
T+
T− 8
T+
T−
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus DB9P (male)
DB9
Figure 2−35. Cable for connecting CM 4000 to Nexus audio router XCPU port.

In these systems, the same physical level number is used on more than one logical level. For example, a switcher could have video on level 1, left audio on level 2, and right audio also on level 2. In Figure 2−36, a 60 x 60 audio level is being used as two 60 x 30 switchers, i.e., with half the outputs assigned to the left channel and the other half to the right channel.
This technique can sometimes help reduce overall switcher size, but requires special entries to the Switcher Description table and the Switcher Outputs table. See Step 9(i) on page 5−41.
60 x 60 video Physical level 2
60 x 60 audio used as
60 x 30 Left and 60 x 30 Right
CB 3000 Control Buffer
page 2−3 for cabling details.
CM 4000 System Controller
House SMPTE time code required
House sync required for vertical inter- val switching.
Figure 2−36. Logical level mapping (example).

The Jupiter system can be used to control RS−232, RS−422, and RS−423 data switchers. In a typical application, a Venus data matrix switcher can be used to route RS−422 machine control signals.
Older model Venus switchers equipped with DM 400 or DM 400A Data Matrix boards require crossover or Y−line cables. Newer model Venus systems are equipped with the DM 400B Data Matrix boards; these boards have software−configurable rear−panel pinout functions and do not require crossover or Y−line cables.§
For complete information regarding jumper settings and cabling, refer to the technical manual supplied with the data switcher.
— For DM 400/400A Data Matrix boards, refer to Appendix L.
— For an overview of DM 400B configuration, see page 5−52. Entries are required on the Switcher Description
table (page 5−35), Switcher Input table (page 5−48), Switcher Output table (page 5−55), CP Input Set (page 5−62), and CP Output Set (page 5−78).
§Type and model of switcher card is shown on front edge of printed circuit board.
Hardware Installation

A single CM 4000 control board can be used to control more than one Crosspoint Bus switcher; however, each physical level must have a unique number. When expanding a system in the field, this may require changing DIP switches or jumpers on the hardware. See Figure 2−37.
Note: Figure 2−37 pictures a mixture of TVS and Venus routers. This is possible only if all switchers are configured to operate on the same type (Super) Crosspoint Bus. For example, older TVS 2000 matrix cards are not capable of operating on Super Crosspoint Bus, but a newer State machine PROM is available which permits Super Cross- point Bus operations (each TVS 2000 board requires the newer State Machine PROM). Later versions of TVS 2000/3000 switchers were shipped with this PROM already installed; a DIP switch setting selects between Super and Extended Crosspoint Bus.

Required when more than 50 matrix boards are installed in switcher.
Figure 2−37. Multiple switcher installation with single CM 4000.

By using separate CM 4000s, physical level numbers may be duplicated from one switcher to another. When expanding a system in the field, this will eliminate the need to change DIP switches or jumpers on the hardware. See Figure 2−38.

Required when more than 50 matrix boards are installed in switcher.
CM 4000 System Controller
Figure 2−38. Multiple switcher installation with dedicated CM 4000s.

The path finding software option allows two or more Jupiter−controlled routing switchers to operate as a system, where one switcher can access the other’s inputs through a number of tie lines. Tie lines can vary in number from one switcher to another, and from one level to another.
Two wiring schemes can be used: sequential wiring, where tie lines are organized in blocks (as shown on page 2−34); and non−sequential wiring (as shown on page 2−35). Sequential wiring requires entries to only one file server table (the “Path finding Data Table,” shown on page 5−174). Non−sequential wiring requires use of an additional table (the “Non−Sequential Path finding Data Table,” shown on page 5−185.)
Connections can start with any input or output number, but thereafter must be sequential. Page 2−34 shows example connec- tions for one level. Notice that the lowest number in an output group must be connected to the lowest number in the corre- sponding input group, and so on.
Due to distance limitations of the CC−2010 Matrix cable, it may necessary to install a separate CM 4000 System Controller for each switcher.
See page 5−174 for an overview of sequential path finding and software configuration requirements.
In some cases, especially when adding tie lines to an existing system, wiring new lines out of sequence may be desirable. Page 2−35 shows example connections for one level.
Due to distance limitations of the CC−2010 Matrix cable, installing a separate CM 4000 System Controller for each switcher may be necessary.
See page 5−174 for an overview of path finding and software configuration; then refer to page 5−185 for additional non−se- quential path finding requirements.
Hardware Installation

Tie lines can be connected starting with any input or out- put but must then follow in sequential order. Inputs
Grass Valley Crosspoint Bus distribution switcher
cable. 50 ft. (15.2 m) max.
CM 4000 System Controller
CC 2010 Matrix cable.
50 ft. (15.2 m) max.
43 44 45 46 47
Grass Valley Crosspoint Bus distribution switcher
CM 4000 System Controller
Figure 2−39. Sequential path finding connections (example).

Crosspoint Bus distribution switcher
cable. 50 ft. (15.2 m) max.
CM 4000 System Controller
CC 2010 Matrix cable.
50 ft. (15.2 m) max.
88 87 45 46
Crosspoint Bus distribution switcher
CM 4000 System Controller
Figure 2−40. Non−sequential path finding connections (example).

Minimum hardware and software requirements have already been described (page 1−8). Follow the instructions supplied with the file server for connection of monitor, keyboard, and mouse.
Jupiter file server(s) are connected to the CM 4000 through an IP hub, switch, or media converter via the “Jupiter LAN.”
The Jupiter LAN is an IEEE 802.3 10/100BaseT network using a twisted pair cable with RJ−45 connectors (Cat 5E Enhanced is recommended). Shielded cable is also recommended, maximum length 60 meters. Compliance with EEC, EMC, EN series, UL− 1950, and CSA C22.2 No. 950−M89 standards requires use of a shielded cable.
Maximum length for unshielded cable is 100 meters.
ÎÎ ÎÎ ÎÎ
ÎÎ
“Remote” PC (see page 2−36)
Î
ÎÎ
Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ Î Î
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ ÎÎÎ ÎÎÎ
ÎÎÎ
ÎÎÎ ÎÎÎ ÎÎÎ Î Î Î Î
ÎÎÎ
ÎÎÎ
CM 4000
Figure 2−41. PC−to−CM connections..
A printer can be connected to the LPT1 port and used to print the contents of an entire Configuration Set in a 132−column format; it can also be used to print the contents of individual tables (page 5−21).
Procedures for installing the Jupiter software on the file server are found in the Field Engineering Bulletin supplied with the software.
A second PC can be installed on the Jupiter LAN in addition to the PC used as the file server. This “remote” PC can be used for certain Jupiter Network Suite (JNS) applications. For details concerning installation, see Appendix I. For information about JNS see page 4−1.


Hardware Installation · switching

CP 300 Series
Power supply requirements − A wall plug−in power supply is supplied with each 300 Series panel that will be used with 110 VAC 60 Hz power. Panels that are to be used in areas where 220VAC 50Hz power is the norm are not shipped with any power supply; the user in these areas must provide a source of regulated 5 VDC power to each panel. The power requirement is +5 VDC +/− 0.25 V at 600 mA. The power connector used on the 300 Series PC board is an RL11A (female) made by LZR Electronics; Grass Valley part no. 30−005724−007.
DIP switch settings − A DIP switch, accessible through an opening in the rear panel, must be set with switch 8 OFF when a 300 Series panel is used in a Jupiter system; the remaining seven switches are ignored. This sets the panel address to the one stored in PROM (which is stamped on the rear panel).
CP 300 24 X 1 Single Bus Control Panel
Installation is shown on page 2−37.
(etc.)
CHG
CHG
VID
A1
A2
CHG
CHG
CHG
A3
A4
A5
Figure 2−43. CP 300 Control Panel (as supplied).
The CP 300 is a single bus control panel that can select one of 24 inputs. The push buttons illuminate to indicate status and can be fitted by the user with transparent labels. The panel is shipped with input and level labels as shown in Figure 2−43—any other labels must be created by the user (please see page 2−58 for more information about installing labels).
The bus to be controlled is entered in the “Output Set” assigned on the MPK Devices table (page 5−107). Also entered on the MPK Device table is an Override Set for the panel; the Override Set (page 5−96) determines which button is as- signed to which source. The left−hand button of the CP 300 (the “0” button in Figure 2−43) will select the first input listed on the Override Set created and selected for this particular panel.
Six Level keys are provided on the right side of the panel for split (breakaway) switching and statusing.
For operating instructions, see page 6−1.
Hardware Installation

CP 310 24 X 8 Eight Bus Control Panel
Installation is shown on page 2−37.
0 1 2 (etc.)
0 1 2 (etc.)
Figure 2−44. CP 310 Control Panel (as supplied).
CHG
CHG
VID
A1
A2
CHG
CHG
CHG
A3
A4
A5
The CP 310 Control Panel is very similar to the CP 300 Control Panel, except that eight buttons on the left side of the panel are used to control eight outputs. Refer to the CP 300 discussion (page 2−38) for installation instructions.
The buses to be controlled are listed in an “Output Set” (page 5−78); the name of the Output Set is entered on the MPK Devices table (page 5−107).
For operating instructions, see page 6−2.
Hardware Installation

CP 320 Push Button Control Panel
Installation of this panel is shown on page 2−37.
CAM1 VTR2 VTR1
CHG OUT
CHG
CHG
CHG
CHG
CHG
CHG
VID
A1
A2
A3
A4
A5
VTR
1 CG
2 NET
3 VCR
4 CAM
5 AUX
EJ SS
PROT
REM
6 FILM
7 PTCH
8 STU
9 TEST
MISC FS SAT TAKE
Figure 2−45. CP 320 Push Button Control Panel (as supplied).
The CP 320 is a full−matrix, category/number control panel. The left-most mnemonic display shows switcher destination (output being controlled), the center display shows the input category/number just selected, and the right indicates switcher status (input now switched to the destination shown).
Sixteen buttons in the center are labeled with input/output categories; this allows the first button press to designate the cate- gory and the second button press to designate the selection number. The factory−supplied categories (“VTR,” “CG,” etc.) can be changed by installing new labels (see page 2−58) and creating a custom category set (see Step 5 on page 5−66.)
Two buttons are located on the far right, the top button for protecting an input and the bottom button for performing a TAKE of the selected input/output. Buttons are also provided for changing the output to be controlled and for selection of specific levels (split switching).
The CP 320 panel is configured using the MPK Devices table (page 5−107). For operating instructions, see page 6−3.
CP 328 Push Button Control Panel
Hardware installation and operation of the CP 328 is the same as the CP 320. Software configuration is slightly different due to the eight−character display windows. See Step 10 on page 5−69.
Hardware Installation

CP 330 Control Panel
Installation of this panel is shown on page 2−37.
CHG
CHG

Figure 2−46. CP−330 Control Panel (as supplied).
The CP 330 can be configured to operate as a 48 x 1 panel, or, as a 24 x 2 panel with the top row of buttons assigned to one output and the bottom row to another.
Installation is very similar to the CP 300 (page 2−38). However, for the 24 x 2 application, on the MPK Devices table, a “Y” is entered in the Expansion Panel column, and, the entry in the Output Set column is the name of an actual Output Set. This Output Set must show the names of the two destinations.
For operating instructions, see page 6−1.
CP 330/6 48 x 6 Six Bus Control Panel
Installation of this panel is shown on page 2−37.

Figure 2−47. CP−330/6 Control Panel (as supplied).
The CP 330/6 Control Panel is very similar to the CP 300 Control Panel, except that six buttons on the right side of the panel are used to control six outputs. Refer to the CP 300 discussion (page 2−38) for installation instructions.
The buses to be controlled are listed in an “Output Set” (page 5−78); the name of the Output Set is entered on the MPK Devices table (page 5−107).
For operating instructions, see page 6−5.
Hardware Installation

Installation of these panels is shown on page 2−37.
The basic control panel, referred to as the CP 3000, can be configured for single−bus operation (allowing selection of a source for one destination), multi−bus operation (allowing selection of a source for several destinations), or full matrix operation (selection of a source for any destination). This panel can be arranged to select one of 20 source categories (VTR, CAM, etc.) and then, using a 10−key pad, a unit within the category. Crosspoint status is provided by the display window. Additional push buttons provide breakaway (control of individual switcher levels such as left audio, time code, etc), chop, lock, protect, and override switching. A password can be assigned to the panel if desired.
The CP 3000 can also be operated in connection with an adjacent CP 3010 expansion panel (see Figure 2−49). For multi−bus control the desired source can be selected on the CP 3000; the CP 3010 would then display the names of eight destinations, beneath which are eight corresponding TAKE keys; one of these would be pressed to complete the switch. The page of eight destinations can be scrolled to display up to 160 possible destinations. A blank panel is supplied when the CP 3000 is mounted without a CP 3010.
The CP 3000/3010 panels are configured using the MPK Devices table (page 5−107).
For operating instructions, see page 6−7.
1 CG
2 NET
3 SAT
A
EJ VCR
4 CAM
5 REM
B
Status for 4 levels
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
Figure 2−48. CP 3000 Switcher control panel with example display.
MORE CLR MENU LEV
Status CAM1 CAM3 CAM2 VTR1 MON1 MON3 MON2 VTR2 Output
∨ ∧ >
Figure 2−49. CP 3010 Ex- pansion panel.
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
Hardware Installation · Overrides

C1 C2 C3 C4 T1 T2 R1 R2 NT V1 V2 V3 V4 V5 SA SB E1 E2 E3 LOCK CHOP V6
Figure 2−50. CP 3020 Push Button Control Panel with example labels.
Installation of this panel is shown on page 2−37.
The CP 3020 is a single−bus control panel that can select one of 20 inputs. The push buttons illuminate to indicate status and can be fitted by the user with transparent labels. The panel is shipped with “Lock” and “Chop” labels and a general purpose “0−99” label set—any other labels must be created by the user (please see page 2−58 for more information about installing labels).
The logical name of the switcher bus (output) that is to be controlled is entered in the “OutSet” column on the MPK Devices Table (page 5−107). Also entered on the MPK Device table is an Override Set for the panel; the Override Set (page 5−96) determines which button is assigned to which source. The left−hand button of the CP 3020 (the “V1” button in Figure 2−50) will select the first input listed on the Override Set created and selected for this particular panel.
For operating instructions, see page 6−26.
CP 3021 Push Button Expansion Panel
C1 C2 C3 C4 T1 T2 R1 R2 NT V1 V2 V3 V4 V5 SA SB E1 E2 E3 LOCK CHOP V6
LO1 LO2 LO3 LO4 81 82 41 42 DM M1 M2 M3 M4 M5 LR LS P1 P2 P3 RR
Figure 2−51. CP 3020 Push Button Control Panel with CP 3021 Push Button Expansion Panel with example labels.
Up to four CP 3021 Push Button Expansion panels can be added to the CP 3020, allowing button−per−input selection of up to 100 inputs. Each CP 3021 is supplied with a 12−inch (305 mm) ribbon cable with installed 37−pin connectors; the cables loop through each expansion unit.
The left−hand button of the CP 3020 (the “V1” button in Figure 2−51) will select the first input listed on the Override Set created and selected for this particular CP 3020. The left−hand button of the first CP 3021 on the ribbon wire bus (the “M1” button in this example) will select the 21st input listed, etc.
Hardware Installation

Installation of this panel is shown on page 2−37.
1 CG
2 NET
3 SAT A
5 VCR
6 CAM
B EMER REM
1 2 3 4 5 6 7 8
Prot Dest Level Over
ride SEQ Audio Menu
Figure 2−52.
The CP 3800 is a universal, eight−character mnemonic, switcher and machine control panel.
This control panel uses an eight−character “CP 3800” type CP Level Set (page 5−58), CP Input Set (page 5−62) and CP Output Set (page 5−78). These sets, and others, are assigned to the panel using the MPK Devices table (page 5−107). and if used for machine control, the Machine Control Devices table (page 5−135). It can also use custom CP Category Sets (page 5−102).
For operating instructions, see page 6−27.

1 VTR CG NET
SAT
VCR CAM REM
EDIT
FILM PTCH STU
FS
TEST MISC AUX
Figure 2−53. CP 3808.
The CP 3808 control panel is a 16−category, full−matrix,* multiple level breakaway panel capable of locking and protecting outputs. The panel features eight−character display capability and relegendable, lighted push buttons.
As an option, the CP 3808 can be operated in connection with an adjacent CP 3809 Expansion Panel (see page 2−48) or a CP 3810 Expansion Panel (see page 2−54).
Installation of this panel is shown on page 2−37.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (CM 4000). For more information, see Diagnostics Mode on page 6−71.
The CP 3808 panel can display eight−character mnemonics for inputs and outputs. To accomplish this create a CP Level Set of type “3800” (page 5−58), a CP Input Set of type “3808” (page 5−67), and a CP Output Set of type “3808” (page 5−82). These sets are among those assigned to each panel using the MPK Devices table (page 5−107).
Although the panel is capable of full−matrix operation, it can be restricted to control selected outputs, or even restricted to control of a single output if desired. Such restrictions are made using the MPK Devices table (page 5−112).
Since the keycaps are relegendable, the CP 3808’s CP Input and Output Sets can use a custom CP Category set (page 5−102).
Before the panel can be used, these sets must be compiled, and the appropriate configuration set made active using the Control Center (page 5−13).
For operating instructions, see page 6−64.
* Defined in Glossary Section

1 VTR
2 CG
3 NET
4 VCR
5 CAM
BLACK BARS TONE SILE NCE
PAGE
PROT
MENU
1 2 3 4
5 6 7 8
9 8 REM 7 SS 6 AUX
0 PTCH 1 FILM
LEVEL
LOCK CHOP
VTR
1 VTR
2 VTR
3 VTR
STU
1 STU
2 EDIT
1 EDIT
EBS
1 EBS
2 TEST
1 TEST
STU TEST SAT FS MISC
PRE−
PRESET
CLEAR
SET TAKE
SEND
Figure 2−54. CP 3824.
The CP 3824 control panel is a locally−programmable, full−matrix,* multiple level breakaway panel capable of locking and protecting outputs. The panel features eight−character display capability and relegendable, lighted push buttons. The 24 but- ton−per−source keys on the left side of the panel are initially assigned to inputs from the file server, but some or all can be re−assigned to new inputs at any time using only the panel itself. Sources can also be selected by scrolling up/down an LED display of “Preset” mnemonics or by using the Category/Number keypad.
Installation of this panel is shown on page 2−37.
For information about changing keycap labels, see page 2−58.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (CM 4000). For more information, see Diagnostics Mode on page 6−87.
The panel can display eight−character mnemonics for inputs and outputs. This is accomplished by creating a CP Level Set of type “3800” (page 5−58), a CP Input Set of type “3824” (page 5−67), and a CP Output Set of type “3824” (page 5−82). These sets are among those assigned to each panel using the MPK Devices table (page 5−107). Also entered on the MPK Device table is an Override Set for the panel (page 5−96); this set determines which of the 24 button−per−source buttons is assigned to which source. The upper left−hand button of the CP 3824 (the “1” button in Figure 2−54) will select the first input listed on the Override Set created and selected for this particular panel.
Although the panel is capable of full−matrix operation, it can be restricted to control selected outputs, or even restricted to control of a single output if desired. Such restrictions are made using the MPK Devices table (page 5−112).
Since the keycaps are relegendable, the CP 3824’s CP Input and Output Sets can use a custom CP Category set (page 5−102).
Before the panel can be used, these sets must be compiled, and the appropriate configuration set made active using the Control Center (page 5−13).
For operating instructions, see page 6−76.
* Defined in Glossary Section

1 VTR CG NET
CURRENT
VCR CAM SAT
PRESET
FILM PATCH STU
Take VIDEO LEFT RIGHT AES1 T/C
Figure 2−55. CP 3830.
The CP 3830 Control Panel is a 12−category, full−matrix,* multiple−level* breakaway* panel which is capable of locking,* protecting,* and chopping* outputs. The panel features eight−character display capability and relegendable, lighted push but- tons.
As an option, the CP 3830 can be operated in connection with an adjacent CP 3809 Expansion Panel (see page 2−48) or a CP 3810 Expansion Panel (see page 2−54).
Dual CP 3830 panels can be configured so that one of the panels is always used for destination selection (see page 5−126). Dual output mode is also possible with two panels side by side.
Installation of this panel is shown on page 2−37.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (CM 4000). For more information, see Diagnostics Mode on page 6−87.
The panel can display eight−character mnemonics for inputs and outputs. To accomplish this, create a CP Level Set of type “3800” (page 5−58), a CP Input Set of type “3830” (page 5−67), and a CP Output Set of type “3830” (page 5−82). These sets are among those assigned to each panel using the MPK Devices table (page 5−107).
Although the panel is capable of full−matrix operation, it can be restricted to control of selected outputs, or even restricted to control a single output if desired. Such restrictions are made using the MPK Devices table (page 5−112).
Since the keycaps are relegendable, the CP 3830’s CP Input and Output Sets can use a custom CP Category set (page 5−102).
Before the panel can be used, these sets must be compiled, and the appropriate configuration set made active using the Control Center (page 5−13).
For operating instructions, see page 6−88.
* Defined in Glossary Section

Up to five optional CP 3809 panels can be associated with a CP 3808 or CP 3830 (but not CP 3830P), providing direct switch- ing and continuous status for up to 40 outputs.
Figure 2−56 illustrates a CP 3808 with a CP 3809 array for control of 24 outputs.
SAT
VTR−041 CAM−002
VCR CAM REM
EDIT
1 STU
2 STU
3 STU
4 STU
FILM PTCH STU
FS
TEST MISC AUX
8 STU 7 STU 6 STU 5 STU
9 STU
10 STU
11 STU
12 STU
17 STU
18 STU
19 STU
20 STU
16 STU 15 STU 14 STU 13 STU
24 STU 23 STU 22 STU 21 STU
Figure 2−56. CP 3808/E (top) with CP 3809/2 Dual Expansion Panel (below).
Installation of this panel is shown on page 2−37. Note that each CP 3809 Expansion panel requires a separate MPK connec- tion.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (CM 4000). For more information, see Diagnostics Mode on page 6−125.
Each CP 3809 Expansion panel requires a separate entry on the MPK Devices table. See “Out Panel” on page 5−108.
The MPK Devices table entry for the main panel (CP 3808 or CP 3830) must have a check mark in the “Expansion” box. The MPK Devices table entry for the CP 3809(s) must not have a check mark. See “Expansion” on page 5−109.
The CP 3809 Expansion Panel keys are assigned to outputs using the CP Output table (page 5−78). Buttons that are left un- assigned can be assigned dynamically by the operator (page 6−124).
For operating instructions, see page 6−124.

VTR−041
VTR1 VTR2 VTR3 VTR4
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILENCE CG−2 CG−3 CG−4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
VTR−041
PRESET
Figure 2−57. CP 3832.
The CP 3832 is a multiple−level* breakaway* panel which is capable of locking,* and protecting* outputs. The panel features eight−character display capability and relegendable, lighted push buttons.
The panel can also be configured as a type “CP 3832L,” in which the right−hand group of six buttons are used for level selec- tion and the panel operates in “sticky levels”* mode. In this case, the “Level” button shown in Figure 2−57 is used to access the first level in the panel’s Level Set (typically video), the “Menu” button is used for the second level (e.g., left audio), etc.
Both the CP 3832 and the CP 3832L can be configured as a 32 x 1 single bus panel (Figure 2−58), as a 16 x 16 “balanced split” panel (Figure 2−59), or as some variation of an “unbalanced split” panel (Figure 2−60).
Figure 2−58. Single−bus configuration. 32 sources
Figure 2−59. “Balanced split” configuration. 16 sources
Figure 2−60. Example of “unbal- anced split” configuration (22 x 10). 22 sources
Unbalanced split panels can be configured to control from 1 to 15 outputs, with keys not used for outputs available to control inputs. For example, if 10 buttons are assigned to outputs then 22 buttons are available for inputs.
Control of additional inputs/outputs is possible using adjacent CP 3832 or CP 3864 expansion panels (page 2−53); the CP 3832 can be also be operated in connection with an adjacent CP 3810 Expansion Panel (see page 2−54).
* Defined in Glossary Section

Installation of this panel is shown on page 2−37.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (such as a CM 4000). For more information, see Diagnostics Mode on page 6−112.
The panel uses an eight−character CP Level Set of type “3800” (page 5−58).
MPK table entries will depend on the application (see page 5−107).
Sources are defined in a CP Input Set of type “cp3832” (page 5−62). Destinations are defined in a CP Output Set of type “cp3832” (page 5−78).
Before the panel can be used, these sets must be compiled, and the appropriate configuration set made active using the Control Center (page 5−13).
For CP 3832 operating instructions, see page 6−100.
For CP 3832L operating instructions, see page 6−117.
Hardware Installation · Hardware Installation · Software Configuration

VTR1 VTR2 VTR3 VTR4
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILENCE CG−2 CG−3 CG−4
VTR−041
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
CURRENT
VTR−041
MON1 MON2 MON3 MON4
STU1 STU2 STU3 STU4
PRESET
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
MONITOR5
KEY2 BACK
BY PASS XMIT
MON8 MON6 MON6 MON5
EDIT1 EDIT2 EDIT3 EDIT4
UP
VTR5 VTR6 VTR7 VTR8
DESTINATION
Figure 2−61. CP 3864.
The CP 3864 is a multiple−level* breakaway* panel which is capable of locking,* protecting,* and chopping* outputs. The panel features eight−character display capability and relegendable, lighted push buttons.
The panel can also be configured as a type “CP 3864L,” in which the upper right−hand group of six buttons are used for level selection and the panel operates in “sticky levels”* mode. In this case, the “Level” button shown in Figure 2−61 is used to access the first level in the panel’s Level Set (typically video), the “Menu” button is used for the second level (e.g., left audio), etc. The Take button is used as a Protect key.
The CP 3864 Control Panel can be configured as a 64 x 1 single bus (Figure 2−62), as a 32 x 32 “balanced split” panel (Figure 2−63), or as some variation of an “unbalanced split” panel (Figure 2−64).
Figure 2−62. Single−bus configuration.
Figure 2−63. “Balanced split” configuration.
Figure 2−64. Example of “un- balanced split” configuration (54 x 10) .
* Defined in Glossary Section

Unbalanced split panels can be configured to control from 1 to 31 outputs, with keys not used for outputs available to control inputs. For example, if 10 buttons are assigned to outputs then 54 buttons are available for inputs.
Except for unbalanced split and CP 3864L configurations, control of additional inputs/outputs is possible using adjacent CP 3864 or CP 3832 panels (page 2−53); as another alternative, the CP 3864 can be operated in connection with an adjacent CP 3810 Expansion Panel (see page 2−54).
Installation of this panel is shown on page 2−37.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (such as a CM 4000). For more information, see Diagnostics Mode on page 6−112.
The panel uses an eight−character CP Level Set of type “3800” (page 5−58).
MPK table entries will depend on the application (see page 5−107).
Sources are defined in a CP Input Set of type “cp3832” (page 5−62). Destinations are defined in a CP Output Set of type “cp3832” (page 5−78).
Before the panel can be used, these sets must be compiled, and the appropriate configuration set made active using the Control Center (page 5−13).
For CP 3864 operating instructions, see page 6−26.
For CP 3864L operating instructions, see page 6−117.
Hardware Installation · Hardware Installation · Software Configuration

The CP 3832 and CP 3864 can be combined to increase the number of sources and destinations to a maximum of 128 x 128. Examples are shown in Figure 2−65.
CP 3832
CP 3864
CP 3832
CP 3864
CP 3864
CP 3832
CP 3864
CP 3864
CP 3864
CP 3832
Figure 2−65.

The optional CP 3810 panel can be associated with a CP 3832, CP 3864, CP 3808, or CP 3830, providing control of up to 80 outputs. The CP 3810 can also be assigned to one output, providing breakaway (split) switching and/or multi−level status.
Figure 2−66 illustrates a CP 3810 with a CP 3832 panel.
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILENCE CG−2 CG−3 CG−4
VTR−001
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
PRESET
VTR−001 PG1
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
Figure 2−66. CP 3832 (top) with CP 3810 Expansion Panel (below).
The CP 3810 can be operated in several modes:
— For multi−bus control the destination can be selected on the CP 3810 and the desired source can be selected on
the main panel (CP 3832, CP 3864, CP 3808, or CP 3830). The CP 3810 can display the names of eight destina- tions. The “page” of eight destinations can be scrolled to display up to 80 possible destinations.
— For single−destination applications, the panel can be configured as a “CP 3810L” and operated with a main
panel or as a stand−alone unit:
When used with a main panel, the desired destination can be selected on the main panel; the CP 3810 will display the status of eight levels. The “page” of eight levels can be scrolled to display additional levels. A breakaway switch can be set up and executed with a single Take command.
When used as a stand−alone status panel, the desired destination is permanently entered on the MPK table (see Software Configuration below). The CP 3810 will display the status of eight levels. The “page” of eight levels can be scrolled to display additional levels.
— The CP 3810 can also be used as a limited−function machine control panel, providing Play and Stop com-
mands for VTRs.
— Alternatively, it can be configured as a “CP 3810S,” meaning that the selected outputs will remain selected
until explicitly changed by the operator.
Installation of this panel is shown on page 2−37. Note that each CP 3810 panel requires a separate MPK connection.
If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller board (CM 4000). For more information, see Diagnostics Mode on page 6−130.
Each CP 3810 panel requires a separate entry on the MPK Devices table. See page 5−107.

For multi−bus control, the CP 3810 Expansion Panel keys are assigned to outputs using the CP Output table (page 5−78).
When used as a machine control panel, the CP 3810 will require entry on the Machine Control table (page 5−135).
For operating instructions, see page 6−126.
Please refer to the JEP 100 installation and operating manual, part no. 071 8376 xx.
Hardware Installation · Operation

MC 3000 Machine Control Panel and CP 3010 Expansion Panel
Installation of these panels is shown on page 2−37.
The MC 3000 machine control panel includes a series of push buttons for motion control (PLAY, STOP, etc.). A variable speed knob, with a color−coded direction/speed indicator, is also included.
The machine to be operated can be selected using the adjacent CP 3010 expansion panel (Figure 2−68), which can display the names of eight machines over a row of selection buttons. Additional pages of eight machines can be called up for display in the window as required. The method by which machines are assigned to the CP 3010 is described in detail later in this man- ual (see Assigning Machines to Control Panels on page 5−141). The CP 3010 can also be used as a limited−function machine control panel, providing Start and Stop commands for VTRs.
The panels must be entered on the Machine Control Devices table (page 5−135) and the MPK Devices table (page 5−107). For operating instructions, please see page 6−132.
REC MODE << >> > >
REC OUT
REC
Figure 2−67. MC 3000 machine control panel.
Status STOP STOP STOP VT01 VC01 VC02 Device
Figure 2−68. CP 3010 expansion panel. ∨ ∧ >
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
TAKE ———
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL

The MC 3010/2 version of this panel is shown in Figure 2−69; installation is shown on page 2−37.
The MC 3010 is used to control four (MC 3010/1 version) or eight (MC 3010/2 version) tape machines. The display window shows the name of the machine presently linked to the button group immediately below. Lighted, re−legendable push buttons are provided for motion control and status.
A special feature of the panel is the GANG START key, which allows a command to be sent to multiple machines simultane- ously.
The method by which machines are assigned to the MC 3010 is described in detail later in this manual (see Assigning Ma- chines to Control Panels on page 5−141).
The panel must be entered on the Machine Control Devices table (page 5−135) and the MPK Devices table (page 5−107). For operating instructions, please see page 6−135.
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
SHIFT
REW
FFD
SHIFT
REW
FFD
SHIFT
REW
FFD
SHIFT
REW
FFD
PLAY GANG START PLAY GANG START PLAY GANG START PLAY GANG START
Figure 2−69. MC 3010/2 Dual 4−Machine Control Panel.
Hardware Installation

Control panels are supplied with general purpose labels already installed. A sheet with additional labels is also provided, and with care, these labels can be substituted for those already installed.
Custom labels. Information and templates for creating custom labels can be found at www.thomsongrassvalley.com in the Support/FAQ area (search for Answer ID “1425” or Keywords “lens chip”). Copies can then be made on overhead projector transparency material. Most Jupiter panels use the “Frutiger” typeface.
Button caps on these panels are removed using a small screwdriver (or a fingernail). Use the small slot between the clear cap and the black portion of the button; the slot can be found along the top or bottom of the button housing.
After removing the cap and diffuser, the bulb (which is an incandescent type) can be pulled straight out.
The Grass Valley part numbers for the bulbs are:
Button size GV part no. Manufacturer Manufacturer part no.
0.7−inch 65−028985−005 Oshino Electric OL−685BPE 0.45−inch 65−028985−007 Siemens LY K380
When re−installing the cap, notice that the small slots used during removal must be on the top and bottom of the button or the cap will not snap into place properly.
Button caps for these panels are most easily removed by pulling them straight off with needle nose pliers. Using needle−nose pliers will insure that only the transparent cap is removed. Do not pry off the entire button top assembly by using a screwdriver or similar tool; this will not provide access to the label. The existing label is held in place with adhesive; scrape off the label and replace it with the new one.

Figure 2−70.
Hardware Installation · Replacing Button Bulbs

Button caps for these panels are most easily removed by pulling back the top edge with the finger tip (see Figure 2−71). For the black-edged buttons on the right side of the CP 3824, use a technique similar to that described above for the CP 3020.

Figure 2−71. Removing CP 3800 series keycaps.
CP/VC 3020
To test the bulbs without sending any commands to the switcher or machines, use the pair of buttons on the right side of the main panel:
Both buttons will flash, showing that the panel is in test mode.
Bulbs on expansion panels can also be tested.
The panel will return to its previous condition.
For MC 3010 diagnostics, please see page 6−137.
CP 300 / 3800 Series Panels
For lamp test information, please refer to Section 4 and the description of diagnostics for the particular panel.
Hardware Installation

An example of hardware connections is shown in Figure 2−72.
“Diamond” and “ASCII” protocols are set on the Serial Protocol table (page 5−30); and the switcher is identified on the MPK Devices table (page 5−123).
Installation of MPK panels was discussed on page 2−38.
Refer to the DD installation manual for information about the Diamond serial ports and operating instructions.

See discussion on page 2−60 for in- formation concerning these cables.
MPK panel may be used as alternate method of send- ing switch commands to Jupiter (CP−3000 shown).
House sync required for vertical interval switching.

G Frame Ground TC Transmit common RA Receive A RB Receive B TB Transmit B TA Transmit A RC Receive common
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
Figure 2−73. Cable for connecting CM 4000 to Grass Valley DD XBAR Port.
Hardware Installation · to CM 4000 · DB9P (male)

VTRs are connected to the LAN through a CM 4000 System Controller board. The protocol is set at the file server, as described later in this manual.
Serial (Sony) bus1

BVU−800 BCB−35/60/65/70/75 DCR−10/18/20/28/34/35
PCB−2600/2650/2800
1See Sony Installation Notes, page 2−61.
Figure 2−74. Connection to Sony VTRs.
CM 4000 System Controller
Only one Sony VTR can be connected per port.
Late model Sony machines use a remote control protocol referred to as Sony serial, and these can be connected directly to individual ports of a CM 4000 board. Sony serial machines include the BVH−2000, BVH−2500, BVU−800, BVW−10, and BVW−40.
Some VTRs not described above use the Sony Serial protocol. Please contact Grass Valley for additional information.
Hardware Installation

Telephone line Modem Modem
Serial (MPK) bus op-
erating at 2400 baud
CM 4000 System Controller
Figure 2−75. Modem control installation.
The Jupiter system can be controlled through a modem connection using:
The modems used in such a system should be connected to the Jupiter hardware through RS−232/422 converters. See Figures 2−75 and 2−76. The only modem supported for this application is the Motorola V.3229, which is available from Black Box Corp. or NetLink Technology, Inc. Two RS−232/422 Converters are recommended: 1), the Black Box IC107A RS−232 > RS−422 Converter, and 2) the Integrity Instruments 422−25I with external power supply. For instructions that apply specifi- cally to these third−party items, please refer to Grass Valley Field Engineering Bulletin 04-047604-081.
Figure 2−76. Generalized modem wiring.
RS−422/232
Transmit B (+) Transmit B (+)
Using the Serial Protocol table, change to the appropriate baud rate for the port that is connected to the modem. Only one control panel can be defined on a port that is connected to a modem. For more information, see page 5−30.

Please refer to Appendix A for installation instructions.
The RS−422 cables used to connect CM 4000 controllers, VTRs, and control panels may be known by various names depend- ing on the devices to which they are connected. Thus a particular serial bus might be called the “Sony bus,” the “MPK bus,” etc. In spite of the different terminology, each of these buses consist of a 4−conductor (plus ground) cable.
Maximum length per bus is 1220 meters (4003 ft).
The rear panel serial data cable connectors on the CM 4000 and MPK control panels are 9−pin D, female. The CP and MC connectors are arranged for loop−through wiring. No termination is required. While these connectors are ESbus compatible, it should be noted that the Grass Valley serial data cables use only 5 of the 9 pins described in the ESbus specification (Appen- dix F).
The following ready−made cables, with installed 9−pin D male connectors, are available from Grass Valley (VDE* cables include ferrite cores):
1 meter (3.3 ft) 8 meters (26.2 ft) 2 meters (6.6 ft) 16 meters (52.5 ft) 4 meters (13.1 ft) 32 meters (105 ft)
For ordering information, see page 1−22.
For those who wish to prepare their own cables, the pin−outs are shown in Figure 2−77. The cable itself should be Belden 8723 or equivalent. Details concerning ferrite cores are given in Figure 2−78.
CM 4000 controller board
Control panel or VTR
Individually shielded, twisted pairs Ferrite core
P2 DB9P (male) Figure 2−77. Serial data cable wiring. Reference: “Assembly, BCS−3000 Serial Data Cable,” Grass Valley drawing no.
01−041600−TAB.
*see Glossary.

User−supplied serial data cables for VDE installations require a ferrite core over each end of the cable, adjacent to the connec- tor.
Type 43 material sources
Type 43 material 0.250 inch (6.35 mm) inside diameter 0.95 inch (24.13 mm) length (or longer)
Fair−Rite, part no. 2643480002
Fair−Rite Products Corp., P.O. Box J, Commercial Row, Wallkill, NY 12589, USA; Tel. (914) 895−2055.
Chomerics, part no. 83−10−A636−1000
Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888 USA; Tel. (617) 935−4850.
Figure 2−78. Serial data cable VDE modifications.
A video reference (sync) signal should be connected to each Jupiter controller board (including the CM 4000 System Control- ler).
This signal may be color black or composite sync with an amplitude between 1 V P−P and 4 V P−P.
The CM 4000 System Controller must have a sync reference in order for a Grass Valley Crosspoint Bus router to switch during the house vertical interval. Crosspoint Bus routers are listed on page 1−11.
Time code must be connected to the CM 4000 for deterministic switching (AccuSwitch application). For more information, see Appendix G.
A time code connection to the CM 4000 also provides an accurate date and time stamp for JNS Logger messages (page 12−1).
If desired, the CM 4000 clock and the file server clock can be synchronized by referencing them to the same time source, such as a time code input (preferred) or a Network Time Protocol server. See page G−11 in Appendix G.
Hardware Installation

The Jupiter control system can be used as part of a Saturn Master Control Switcher installation, as shown in Figure 2−80. §
Jupiter and Saturn software programs are presently supplied on a multi−disk set, and running the “Install” program loads both Jupiter and Saturn code.
Saturn software is accessed using the “Saturn” pull down menu. See Figure 2−79.

Figure 2−79. Jupiter/Saturn Configuration menu.
Before attempting to connect and configure the Saturn Master Control Switcher, the Jupiter Facility Control System should first be installed and checked out.
For Saturn installation instructions, including hardware connections and entries to Jupiter configuration tables, please refer to the Saturn Master Control Switcher Installation and Operation Manual, Grass Valley part no. 04−046654−002.
The Saturn Tally system, which operates only with the Saturn internal matrix option, is described in the Saturn installation/ operating manual. For Jupiter Tally applications, where signals are followed through routers or production switchers, refer to page 2−67 of this manual.
For Under Monitor Display installation instructions, see page 2−81.
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27.
Hardware Installation


ÎÎ ÎÎ ÎÎ Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ Î ÎÎ
ÎÎÎ ÎÎÎ ÎÎÎÎ Î
Î ÎÎ Î ÎÎ Î ÎÎ Î ÎÎ Î
Figure 2−80. Example of Saturn MCS with Crosspoint Bus router and Jupiter control system. For Saturn instructions, see Saturn Master Control Switcher Installation and Operating Manual.
Hardware Installation · 10/100baseT LAN · 10base2 LAN

To tally lights, switchers, etc.
Serial data cable (see page 2−63)
MI 3040 General Purpose/Tally Interface
LAN
Sync ref.
See pg.
Figure 2−81. MPK connections to MI 3040.
Grass Valley offers the following software packages for operating tally systems:
The MI 3040 General Purpose / Tally Interface can be used either to monitor the status of switching equipment, or to provide a voltage source for tally lamps, or both.
Certain third−party tally systems can also be used with Jupiter. See the “Key Features” table beginning on page 1−27.
† In certain systems, special configuration techniques will allow Jupiter to tally outputs and operate multi−level (air+pre-
view+iso) tally systems. For more information, see Grass Valley technical paper “Advanced Tally Techniques for Studios with Jupiter Control and DD-35 Series Production Switchers.”

Relay Outputs
The MI 3040 provides 40 electrically isolated output connections for operating tally lights, using solid−state switches which are suitable for low−voltage (
Note 1: The Jupiter Tally system can only operate tally lights for sources that are connected directly to the Jupiter− controlled router as inputs. If a source is instead connected to a production switcher, or to a non−Saturn, non−MCS 2000 master control switcher, then the tally light for that source must be operated by that switcher’s tally relay system—not by the MI 3040.
Note 2: When the master control switcher feeds the transmitter indirectly (by re−entry through the routing switcher), a relay number must be entered on system configuration tables (as described in detail later) for a tally light assigned to the master control switcher. Relay numbers must also be entered on system tables for tally lights mounted next to production switchers. However, physical installation of these lights is optional. Whether these lights are installed or not, the sources upstream of the switcher(s) will still be tallied.
40 opto−isolated inputs are provided on the MI 3040 to receive tally data from production switchers and/or non−Saturn, non− MCS master control switchers, allowing the Jupiter system to determine what source has been selected by such switchers. This information is used along with Jupiter−controlled router status data to illuminate the appropriate tally light(s).
The MI 3040 connects directly to a CM 4000 serial port using MPK protocol (Figure 2−81). Multiple MI 3040s can be in- stalled as needed. Since information is shared among all units, tally lights can be operated by one MI 3040 based on switcher data received at another.
For a Saturn stand−alone system, where no CM 4000 is available, the Saturn video processor (either digital or analog) is used as the source of the MPK bus.
In many cases current sources will need to be found to operate the tally lamps and energize the opto−isolators. Although +5 V and ground utility connections are available on the back panel of the MI 3040, this supply may not be sufficient for the particular installation. Before attempting these connections, please refer to the hardware overview starting on page 2−77.
Connecting production switchers and/or non−Saturn, non−MCS master control switchers to the MI 3040 opto−isolators will require an understanding of the switcher’s tally relay hardware. Please refer to the installation manual supplied with the switcher for more information.
Hardware Installation

The following diagram shows an example of a Saturn Tally system. For detailed information, refer to “Saturn Tally” in the Saturn Installation and Operating Manual.

Î ÎÎ ÎÎ ÎÎ Î ÎÎ Î ÎÎ ÎÎ ÎÎ Î
When used as a connection point for an MPK bus, the Saturn video processor must be entered on the Serial Protocol table (page 5−30).
All sources must be connected directly to internal matrix.
One connection per tally light. 100 V, 300 mA max.
40 relays. Wiring order is de- termined automatically. See Saturn Installation and Oper- ating manual.
Figure 2−82. Saturn Tally system.
Hardware Installation

The diagrams on the following pages show systems that can be controlled by the Jupiter Standard Tally application.
A Saturn (or MCS 2000) master control switcher can feed the transmitter directly (page 2−71) or indirectly by re−entering the routing switcher (page 2−72). The main difference between these two systems is the tally light next to the master control switcher.
Each tally light that is to be controlled by the Jupiter system requires one relay connection, as shown.
Systems can include one or more production switchers (page 2−73 and following). For each feed from the Jupiter−controlled router to the production switcher(s), there must be a connection to one of the 40 opto−isolators of the MI 3040.
No connections from the Saturn master control switcher to the MI 3040 opto−isolators are needed; tally data is transmitted through the MPK bus.
The master control switcher can feed the transmitter directly (Figure 2−87) or indirectly by re−entering the routing switcher (Figure 2−88). The main difference between these two systems is the tally light next to the master control switcher. For each feed from the Jupiter−controlled router to the master control switcher, there must be a connection to one of the 40 opto−isola- tors of the MI 3040. Each tally light that is to be controlled by the Jupiter system requires one relay connection, as shown.
Systems can also include one or more production switchers. For each feed from the Jupiter−controlled router to the production switcher(s), there must be a connection to one of the 40 opto−isolators of the MI 3040.
The MI 3040 must be established as an MPK device for tally use, after which it is referred to as a “MI 3040/T” (page 5−115). The Tally Relay and Tally Dependency tables must also be filled in, as described starting on page 5−152.
When used as a connection point for an MPK bus, the Saturn video processor must be entered on the Serial Protocol table (page 5−30).
The Grass Valley SlimLine series UMDs include self−powered tally LEDs. For more information, see page 2−81.
Hardware Installation


One connection per tally light. 100 V, 300 mA max.
40 opto−iso- lators. See Fig. 2−91.
Figure 2−87. Multi−switcher tally system with production switcher, Jupiter−controlled router, non−Saturn/MCS 2000 master control, and direct feed to transmitter.
Hardware Installation


One connection per tally light. 100 V, 300 mA max.
40 opto−iso- lators. See Fig. 2−91.
Figure 2−88. Multi−switcher tally system with production switcher, Jupiter−controlled router, non−Saturn non−MCS 2000 master control, and indirect feed to transmitter.
Hardware Installation

Osc. 3.6864MHz
68HC705
RESET
Gen.
PORT B
PORT B RS−422 Driver/Receiver
Figure 2−89. MI/MC 3040 interface block diagram.
The MI/MC 3040 interface provides 40 switch closures, monitors 40 isolated status inputs, and interfaces with a CM 4000 using MPK protocol.
(Reference: Fig. 2−90.) The relay selected for this design is an optically−coupled solid−state relay (PVD1352 by International Rectifier) capable of switching from 0 to 100 volts (AC or DC) at up to 300 mA. Each relay may be configured by slide switch for normally−open or normally−closed operation.
Each relay drive signal passes through a two−input exclusive−OR gate. The second input to each gate is tied to a DIP switch to ground and pull−up. When a switch is in the OPEN or OFF position, the corresponding relay is considered normally open; a high level on the relay drive line (inverted to a low level) will consequently close the relay. Conversely, when a switch is in the CLOSED or ON position, the corresponding relay is considered normally closed; a high level on the relay control line will cause this relay to open.
(Reference: Fig. 2−91.) The optical coupler inputs respond to a differential voltage between the two input pins. The optical couplers selected for this design are a bipolar type (PC314 by Sharp, for example) to eliminate the need for external steering diodes. The signal leg contains a series current−limiting resistor selected to provide between 1.75 and 13.6 milliamps of LED drive current at voltages of 5 to 28 volts (AC or DC).

+5 V and ground utility connections are provided on the back panel. There are two +5 V connectors, each of which is equipped with a PCB−mounted 1 amp fuse. The fuse is designed to reset itself automatically.
9 10 11 12 13 14 15 16
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
PVA1352
8 RDB (31)
+5V
J2−B9
R1
1 U84
3 R9
10K VBRD (31)
F86 [SMT]
RDA (31)
J2−B8
See Figure 2−92.
Figure 2−90. MI/MC 3040 optoelectronic relay circuit (example). For discussion, see page 2−77.
R137
U69
10K
OPTO (31) 4
PC314
R89
2K STB (31)
J1−B9
STA (31) J1−B8
(TM2)
Figure 2−91. MI/MC−3040 optical coupler status circuit (example). For discussion, see page 2−77.

Switch Relay Switch Relay Switch Relay Switch Relay Switch Relay
S1−1 24 S1−2 25 S1−3 26 S1−4 27 S1−5 28 S1−6 29 S1−7 30 S1−8 31
S2−1 32 S2−2 33 S2−3 34 S2−4 35 S2−5 36 S2−6 37 S2−7 38 S2−8 39
S3−1 8 S3−2 9 S3−3 10 S3−4 11 S3−5 12 S3−6 13 S3−7 14 S3−8 15
S4−1 16 S4−2 17 S4−3 18 S4−4 19 S4−5 20 S4−6 21 S4−7 22 S4−8 23
S5−1 0 S5−2 1 S5−3 2 S5−4 3 S5−5 4 S5−6 5 S5−7 6 S5−8 7
UP = this relay normally open
1 1 2 3 4 5 6 7 8
DOWN = this relay normally closed
Figure 2−92. MI/MC 3040 normally open/closed relay DIP switches.
Hardware Installation · Reset


Figure 2−93. MI/MC 3040 back panel.
Hardware Installation

Figure 2−94. SlimLine Under Monitor Status Displays (Standard screw mount models shown).
UMD 14 SD

UMD 19 DD
UMD 19 UD
Using Under Monitor Displays, the Jupiter system can display the name of a source (camera, VTR, etc.) when it is switched through a Jupiter−controlled router to a particular monitor. In multi−switcher applications, the system can follow a source through as many as five switchers, including production switchers and Saturn master control switchers. Also available is a fixed mode of operation, during which the desired source name is displayed permanently.
The Grass Valley SlimLine UMD SD/DD/UD displays shown above can be configured with some character positions used as “tally lights”; these lights can be configured to illuminate when the source shown is switched to a particular destination (e.g., on−air). The SlimLine displays are available in 9−, 12−, 14−, and 19−inch−wide versions.
Each type is also available in a space−saving plate− mount (“OB”) version for installation in front of a monitor, i.e., in front of the monitor’s controls, not the screen (see Figure 2−95). The mounting plate slides under the monitor and a hinge allows the dis- play to swing down when the monitor controls re- quire adjustment. For more information, refer to the equipment dimensions on page 1−15 and to the SlimLine Under Monitor Displays Technical Manual.

Installation of the SlimLine Controller and UMDs is shown below. Up to 16 various UMD models can be mixed or matched per SlimLine Controller. Multiple SlimLine Controllers can be daisy chained on the MPK bus if desired; in which case the associated rear−panel switch is set to “0” (non−terminate) instead of “1” (terminate MPK bus).
Hardware Installation

Hardware Installation

SlimLine UMDs are connected to the Jupiter CM 4000 through a SlimLine Controller, which has RJ45 ports for Cat 5 Ethernet cable connection to 16 UMDs. Power is provided to the UMDs through the Cat 5 cables. See Figure 2−96.
Figure 2−96. SlimLine UMD Status Display installation.

Cat 5 cable (see Note 2 on page 2−82)
Under monitor status displays must be identified as MPK devices. See page 5−116.
If SlimLine UMD tally light operation is needed, additional configuration will be required:
Hardware Installation · AC power

A Saturn application is shown in Figure 2−97. No additional connections to the master control switcher itself are required, since all status data is transmitted on the LAN (page 2−65).

Cat 5 cable (see Note 2 on page 2−82)
Figure 2−97. Example of status display system for Saturn master control switcher.
Two methods are available for configuring UMDs with Saturn systems:
Hardware Installation

Using the “Jupiter control” method, UMDs can be used to display the names of inputs that pass through a production switcher as well as the Saturn. See Figure 2−98.

Figure 2−98. Use of MI 3040 with UMDs and production switcher.
Cat 5 cable (see Note 2 on page 2−82)
Hardware Installation

Since production switchers do not use the Jupiter LAN, an MI 3040 General Purpose / Tally Interface must be used to obtain switcher status. For each feed from the Jupiter−controlled router to the switcher(s), there must be a connection from a switcher tally relay to one of the 40 opto−isolators of the MI 3040. This allows the system to determine what source has been selected by such switchers. This information is used along with routing switcher status data to display the appropriate mnemonic.
The MI 3040 connects directly to a CM 4000 serial port using MPK protocol. Since information is shared among all units, status displays can be operated by one CM 4000 based on MI 3040 data received at another.
Connecting production switchers to the MI 3040 opto−isolators will require an understanding of the switcher’s tally relay hardware. Please refer to the installation manual supplied with the production switcher for more information. (The MI 3040 hardware is discussed on page 2−77.)
Under monitor status displays must be identified as MPK devices. See page 5−116.
In systems which include production switchers, entries to special CP Output Set tables and entries to the Tally Relay Descrip- tion and Dependency tables will be required (see page 5−119).
If SlimLine UMD tally light operation is needed, additional configuration will be required:
Hardware Installation

The CM 4000 will support multiple connections to an automation system (e.g., “channel A control” of an automation system could be connected to Serial Port 1 of the CM and “channel B control” connected to Serial Port 2).
CM 4000s can be installed as a redundant pair where each monitors the other. If a fault is detected in the [active] master unit, control will be switched to the other device automatically. For more information, see page 2−8.
“ESswitch” protocol is set on the Serial Protocol table (page 5−30); and the control computer is identified on the MPK Devices table (page 5−107). A technical description of the proposed dialect is available; please contact Grass Valley for more informa- tion.

See pages 2−89 and 2−90 for examples of this cable
vertical interval switching.
Figure 2−99. Example of Automation installation.
Hardware Installation · switching

See pages 2−89 and 2−90 for examples of this cable LAN
Controller Sync ref. See
pg. 2−64
Figure 2−100.
These systems are similar to that shown on page 2−87. “ASCII” protocol is set on the Serial Protocol table (page 5−30); and the control computer is identified on the MPK Devices table (page 5−107). A technical description of the Jupiter ASCII com- puter interface protocol is presented in Appendix N.
This method is also used for connection to an Image Video TSI−100 tally system.

Serial port to MSL 4000
IFS 4
G
G
G
G
G
RJ45P
Belden 8723 or equivalent
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground
Figure 2−101. Cable for connect- ing CM 4000 to MSL 4000 IFS 4.
= Shielded, twisted pair

G
G
R−
T−
R+
T+
T− 8
R+
R−
RS−422/232
LG
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
† A Black Box model GJ−IC455B Inter-
Tx Transmit Rx Receive LG Logic ground
face/converter is available from Grass Valley; part no. 05−040935−001.
Figure 2−102. Cable for connecting CM 4000 to AT−type computer..
G
R−
T−
R+
T+
T+ R+
T− 8
R−
RS−422/232
LG
G Ground R− Receive minus R+ Receive plus T+ Transmit plus T− Transmit minus
† A Black Box model GJ−IC455B
Interface/converter is available from Grass Valley; part no. 05−040935−001.
Figure 2−103. Wiring for connecting CM 4000 to 25−pin PC−type serial port..
Rx Receive Tx Transmit LG Logic ground

The Encore System Controller Board (SCB) can send switching commands to a Jupiter control system (which can in turn send the commands to a Crosspoint Bus router such as Venus). This application uses the “ESswitch” Proposed ESbus Routing Switcher Dialect.
Hardware connections are the same as those used when Jupiter controls an Encore system. See page 2−17 and following.
“ESswitch” protocol is set on the Serial Protocol table (page 5−30); and the Encore SCB is identified as a Serial device on the MPK Devices table (page 5−123). In the case of redundant VM / redundant SCB systems, two VM ports are defined on the Serial Protocol table and two SCBs are defined on the MPK Devices table.
A technical description of the proposed ESswitch dialect is available; please contact Grass Valley for more information.
Hardware Installation

Hardware Installation

If the file server was purchased from Grass Valley, the software will have been installed at the factory. In this case, for quick system startup you may wish to refer to the Jupiter Getting Started Guide, part no. 04-045707-003. This booklet provides an abbreviated version of the configuration instructions in this manual.
If the Jupiter software is being upgraded from a previous version, you must follow the special upgrade instructions in the appropriate Grass Valley Field Engineering Bulletin. Failure to do so could result in loss of user data. For more information, please contact Grass Valley Technical Support (see page ii in the front of this manual).
If the software is being installed for the first time, follow the procedure in the Field Engineering Bulletin.

Software installation

The JNS Control Console is the application used to launch the various Jupiter Network Suite (JNS) programs. It is also used to launch the Jupiter Configurator (table editor).
The Jupiter Network Suite is a collection of several programs designed as a replacement and enhancement to the Jupiter Net- work Interface Application (JNIA) software. JNS programs include:
Software Control Panel Suite (GUI control panel) Board Status Control Center§
CP IO Set Editor†
JNS Configuration Logger§ and LogViewer§
Physical Diagnostic Utility†
Physical Remapping Utility†
Router Control Utility Router Save/Restore
Software must be installed as described in Field Engineering Bulletin supplied with the software.
At the end of the installation process, the JNS programs can be activated using the JNS Control Console application.
The JNS Control Console is located at Start > Programs > Jupiter Network Suite > JNS Console. When the program is launched, the window shown in Figure 4−1 will appear.
§ This application replaces a similar program used in connection with the Jupiter Network Interface Application (JNIA). † This application cannot be run on a “Remote” PC (a Remote PC is shown on page 2−36).
Force Unlock§ · Physical Control§


Figure 4−1.
The JNS Control Console must be “connected,” i.e., directed to examine/control a particular computer. In this example, there is only one computer—the “File Server.” Click on the computer, then Connect. A menu similar to that shown in Figure 4−2 will appear.

This condition is normal at this stage of installation; click “OK.” Creation and selection of sets is described in the next section of this manual.
JNS Control Console


Figure 4−2.
The “connection” step will automatically launch certain JNS “servers” (programs) on the File Server PC. Running programs are indicated by the term “Local.” These background programs provide data needed by other software: specifically, the JNS Applications, Tools, and Utilities. These three program groups, which are shown across the top of the window, consist of the following programs:
Page
Control Center 9−1 CP IO Set Editor† 10−1 LogViewer 12−1 Logger 12−1 Router Control Utility 17−1 Saturn Monitor Follow & Preview ‡
Software Control Panel Suite (GUI control panel) 7−1
Configuration editor (“Configurator”) 5−1 Board Status 8−1 Force Unlock 11−1
† Not supported by AccuSwitch. ‡ Not supported by CM 4000.
JNS Control Console

Party Line Download †
Physical Control 14−1 Physical Remapping Utility 16−1 Router Save/Restore 18−1
Physical Diagnostic Utility 15−1
Click on the appropriate group button, then the program button. For information about individual programs, refer to the page number shown.
When the Jupiter system is set up initially, the “Jupiter Configurator” must be used next. This is described in Section 5 of this manual.
† Not supported by CM 4000.
JNS Control Console

Following hardware installation, all connections to the Jupiter system including those for control, video, audio, data, and tally must be identified and described in a “Configuration Set” consisting of a collection of user−defined tables. The configuration editor (“Configurator”), the editing program used to create and edit these tables, is designed to eliminate manual entry of re- petitive information and operate in a familiar, “Windows−like” environment. Editing features include search, error detection and on−screen help, column/row copy/paste, and column/row auto−fill with incremental numbers.
Installation of the Configurator is described in the Field Engineering Bulletin provided with the software.
Quick Start tip: If your Jupiter equipment was purchased from Grass Valley as a “turnkey” system, you may wish to refer to the Jupiter Getting Started Guide, part no. 04−045707−003. This booklet provides an abbreviated version of the information in this section.
Quick Start tip: If you are an experienced Jupiter user, and wish to check the routing switcher as quickly as possible, see Using the Numeric Set on page 5−11.


Figure 5−1.
Jupiter Configurator menu with Network Description table open.
If a password entry menu appears, it means that a Jupiter password (other than the factory default of “999999”) has been set. Enter the authorized password and click on “OK.”
The password system is discussed in detail starting on page 5−22.
To close (quit) the Configurator, select “File > Exit” or click on the Close Box (X) in the upper right−hand corner of the win- dow.
Other than for convenience, there is no need to leave the Configurator loaded after compiling. However, the JNS application should be left running and the download connection to the CM 4000 System Controller should be left in place, in case the a controller board requests a fresh download of data from the file server.
Configurator

This function is designed to expedite the data entry process and eliminate errors due to differences in spelling and entry of inappropriate data.
In cases where a controller board or device must be entered on more than one table, Configurator will automatically copy (or offer as a selectable item) the data entered on the “initial entry” table to all “secondary” tables (including Saturn tables). Enter- ing information in the same order as the tables appear in the pull−down menu will therefore eliminate most repeat entries. For example, when a CM 4000 is entered on the Network Description table, the name will be added automatically to the Serial Protocol table.
When certain items are deleted, the editor will automatically delete, when appropriate, the corresponding entries on other tables. For example, when the name of an input is deleted from the Switcher Input table, the input will be deleted automatically from the other corresponding tables. The same is true for an output deleted from the Switcher Output table. For instance, if the VTR12 row on the Switcher Input table is deleted, the corresponding row on the CP Input Set table, i.e., the row defining the category/number keys and mnemonic, will be deleted as well.
Configurator

When creating a name for a Jupiter set, table, control panel, or other device, it’s a good practice to use letters and numbers only. If you want to use punctuation or special characters, check the list on page 5−7 before creating a name.
Important: It is possible to reorder Jupiter tables, but this can be very disruptive if not done carefully. The order of entries in certain tables is significant because row numbers are used as cross−references to other tables. If data is moved from one row to another, these relationships may be broken and system operation will be unpredictable. When adding new items to tables, add them at the end if possible. If you wish to reorder table data then you must be prepared to clear battery−protected memory (Pmem) in the system controller and re−establish switcher status and machine links. Clearing Pmem is described in Appendix B.
Configurator

“Edit > Find” − searches for a text string in all open tables.
“Edit > Fill” − this is a copy/paste function for use with tables containing repetitive material. Select the row or column with the desired text and then “Edit > Fill Right” or “Edit > Fill Down” to paste the information.
“Edit > Increment” function − similar to “Edit > Fill” except that incrementing numbers are automatically created in columns to the right or rows below as desired. For example, on the Switcher Input table you could enter “IN 1” in the top left field, then select the desired fields (the whole column in this example) and “Edit > Increment Down.” This will fill the rest of the column with “IN 2,” “IN 3,” etc. to the bottom of the table. It is also possible to mix categories (prefixes) within a column and still automate the process. For example, “VTR 1” could be entered in the top left field, the following 10 rows selected and “Edit > Increment Down” applied; this would produce 10 rows labelled VTR 1 through “VTR 10.” “CAM 1” could then be entered in the Name field on row 11, additional rows selected, “Edit > Increment Down” applied, etc.
Before changing an existing Jupiter table, be sure to read “Important” on page 5−4.
Figure 5−2.
Input Set — KXYZ−INP
Category Entry Mnemonic Logical
2 CAM 2 C2 CAM2
3 CAM 3 C3 CAM3
Next, select the top left field of the destination area. In this case, the paste will overwrite the existing text.
Figure 5−3.
Input Set — KXYZ−INP
Category Entry Mnemonic Logical
2 CAM 2 C2 CAM2
3 CAM 3 C3 CAM3
Then use “Edit” and “Paste.” the result is shown in Figure 5−4.
Figure 5−4.
Input Set — KXYZ−INP
Category Entry Mnemonic Logical
CAM1
2 CAM 2 CAM2
CAM2
3 CAM 3 CAM3
CAM3

To select an entire column, click the name of the column. Click anywhere outside the column to un−select.
To select an entire row, click the number of the row. Click anywhere outside the row to un−select.
Before copying from a Windows program to Jupiter, be sure to read “Important” on page 5−4.
You can use Cut, Copy, and Paste to exchange information between Jupiter and other Windows programs such as Microsoft Word and Microsoft Excel. For example, suppose you want to create a Jupiter CP Input Set using Microsoft Word or another Windows text editor. The document might look like this:
VTR 1 VT01 VT01 VTR 2 VT02 VT02 VTR 3 VT03 VT03 VTR 4 VT04 VT04 VTR 5 VT05 VT05 VTR 6 VT06 VT06 VTR 7 VT07 VT07 VTR 8 VT08 VT08 VTR 9 VT09 VT09 Figure 5−5. Text as entered using word processor.
The text must be “tab−delimited” (as indicated by the arrows). Spaces must not be used between columns. In the case of a Microsoft Excel or other Windows spreadsheet document, each field would be entered in a separate cell.
You can drag−select this text, make a note of how many rows you have selected, and use “Edit” and “Copy” in the Word win- dow. Then select the Jupiter CP Input Set window and select the row number box above where you want to paste. If you want to insert new rows, press the INSERT key once for each row to be pasted. Then use “Edit” and “Paste.” The result is shown in Figure 5−6.
Input Set — KXYZ−INP
Category Entry Mnemonic Logical
VTR 2 VT02 VT02
3 VTR 3 VT03 VT03
VTR 4 VT04 VT04
VTR 5 VT05 VT05
VTR 6 VT06 VT06
VTR 7 VT07 VT07
VTR 8 VT08 VT08
Figure 5−6. Resulting Jupiter table.
The same technique can be used to copy from Jupiter and paste into another Windows program.
Configurator · Keyboard Shortcuts · Input

When creating a name for a Jupiter set, table, control panel, or other device, the following rules should be observed:
Letters A through Z
Numbers 0 through 9
Underscore _ Number sign # Hyphen − Caret ^ Dollar sign $ Exclamation point ! Percent sign % Ampersand & Braces { } At sign @ Single quote mark ‘ Apostrophe ’ Right parenthesis )
Space Comma , Colon : Semicolon ; Forward or back slash / \ Asterisk * Period . Left parenthesis ( Plus + Equal = Less or Greater than < > Brackets [ ] Question mark ? Double quotes ” Vertical bar (pipe) |
Configurator

The top of the Configurator menu (page 5−9) shows the name of the selected set. This is the system configuration directory that is currently selected for editing.
After a set is edited, it should be saved and then compiled. If compiling is successful, the set name will appear on the Jupiter Network Suite Control Center “Application” menu; the set can then be selected for downloading, during which a copy is sent to the system hardware. Another copy always remains in the server, ready for automatic, on−demand download to the hardware.
The Jupiter can have any number of configuration sets, each of which contains the file and subset types shown on page 5−12. (The files in quotation marks are example names.)
Any one of the configuration sets can be selected for use by the system. This allows the entire system to be reconfigured from the file server with only a brief interruption to normal operations.
Quick Start tip: Program the system in small steps and compile often!
As described earlier, a compiled and/or active configuration set cannot be edited directly. And, since creating a new configura- tion set from scratch is a very time−consuming process, you will probably want to make changes by making a copy of the uncompiled (source) version of the set, editing it, and then switching the new set on−line. While any number of file manage- ment schemes can be used to accomplish this, the following procedure is suggested:
Make a copy of the most recent, known−good source set. Name the copy “CONFIG01.”
Edit “CONFIG01.” Save the set.
Compile and Download “CONFIG01.”
When the next change is needed, select and copy source set CONFIG01. Name the copy “CONFIG02.”
Edit “CONFIG02.” Save. Compile and download.
Repeat above steps as needed.
Eventually you will want to start deleting the older sets.
By numbering the sets, there will never be any doubt about which is the latest version. Also, it will be easy to return to “known good” sets. This suggestion is detailed in the steps below.
Configurator


Configurator

Make a copy of the latest known−good set as follows:
This menu will list all existing system configuration sets.
The NUMERIC sets are factory−supplied sets provided for quick start and diagnostic purposes. For more information, see page 5−11. The list may also contain a test set used at the factory.
C:\PROGRA~1\Thomson\J
NUM−64 NUMERIC NUM−LE VGA−DEMO
CONFIG01
Figure 5−8. Select Edit Set menu.
When creating a name for a Jupiter set, table, control panel, or other device, it’s a good practice to use letters and numbers only. If you want to use punctuation or special characters, check the list on page 5−7 before creating a name.
In keeping with the suggestion described earlier, you may wish to name the copy “CONFIG01.”

Editing procedures for specific modifications are described later in this manual, starting with the Network Description table on page 5−27. From the Network Description table, you should move on to the Serial Protocol table, then the Switcher De- scription table, and so on through the remaining Jupiter tables. See page 5−12.
Not all tables will apply to every system. For example, some are for machine control, others are for backward compatibility with Philips/BTS Party Line equipment, etc. Please refer to the description of each table for more information.
The factory−supplied numeric configuration sets can be used to set up and operate the routing switcher in the minimum possible time. The “NUMERIC” set provides for a switcher with up to 256 inputs, 256 outputs, and four levels; the “NUM−64” set provides for 64 inputs and outputs; and the “NUM−128” set provides for 128 inputs/outputs.
The numeric sets are complete and ready to download, except for entry of at least one CM 4000 Control Chassis address, entry of the actual switcher Physical Levels and Driver types, and one switcher control panel address.
Use the “File > Open” menu to select one of the Numeric sets and make a copy (as described on page 5−10.)
Select “Jupiter > Network Description” table and change the CM 4000 address(es) to match those in your sys- tem (see page 5−27). The actual switcher Physical Levels and Driver types are entered on the Switcher Descrip- tion table (page 5−35). The control panel address must be entered on the MPK Devices Description table (page 5−107).
The set can then be compiled and activated as described on page 5−13.
Inputs and outputs are selected numerically, using the TEST key on a CP 3000 control panel to enter a leading zero for selections zero through 99. The VTR key is used to enter a “1,” and so on. For complete CP 3000 operat- ing instructions, see page 6−7.
Configurator

——Network Description ——Serial Protocol
——Network Description ——Serial Protocol
——Switcher Description ——Switcher Input ——Switcher Output
——Switcher Description ——Switcher Input ——Switcher Output
——“KXYZ−LEV” —— ——CP Input Sets
——“KXYZ−LEV” —— ——CP Input Sets
——“KXYZ−INP” —— ——CP Output Sets
——“KXYZ−INP” —— ——CP Output Sets
——“KXYZ−OUT” ——“MC−OUT” ——“SHOP” ——“DELAY−OUT” ——etc. ——CP Override Sets
——“KXYZ−OUT” ——“MC−OUT” ——“SHOP” ——“DELAY−OUT” ——etc. ——CP Override Sets
——“KXYZ−OVE” —— ——CP Sequence Sets
——“KXYZ−OVE” —— ——CP Sequence Sets
——“KXYZ−SEQ” ——CP Category Sets
——“KXYZ−SEQ” ——CP Category Sets
——Machines ——Machine Control ——Delegation Groups
——Machines ——Machine Control ——Delegation Groups
——Status Display Header ——VGA Status Display
——Status Display Header ——VGA Status Display
——Sequential Path Finding ——Non Seq Path Finding
——Sequential Path Finding ——Non Seq Path Finding
——Time Standard ——Video Reference ——CM VGA Options†
——Time Standard ——Video Reference ——CM VGA Options†
Figure 5−9.
† This function is optional. See Appendix H.

If a validation error is reported, move the cursor to the red−colored area of the table to view the reason for the error. Correct the error and run the validator again.
If a compiler error is reported, the error must be corrected and the set re−compiled. To print the error messages, click on the “Print” command box.
Don’t worry about an error corrupting the active set—even if the active set has the same name as the one you’re working on. A new set must compile without errors and be explicitly selected for downloading by the Control Center software before it can go online.
A background program called “Bootp Server” will also be started automatically.

Figure 5−10.
Configurator

After a few seconds, the LEDs on the controller boards will turn red momentarily and the message “Device not con- nected” or “Startup” will appear on the system control panels. When the download is complete, the LEDs should be green and the panels returned to their previous status display. Depending on several factors such as the number of boards, configuration size, need to update the *.sys file, LAN transmission rate, LAN traffic, etc., a complete set change can take several seconds or multiple minutes.
Download status can also be determined using the Control Center “Board Status” tab.
For more information about Control Center functions, including the “Reboot” and “Restore Backup” buttons, see page 9−1.
Configurator

Please refer to Figure 5−11.
In order to minimize system downtime due to changes in configuration and application code and to provide the operator the ability to coordinate the time that the system is unavailable, modifications were made to Windows and the CM 4000 embedded code resulting in a different configuration set and code activation procedure compared to previous Jupiter releases.
With the CM 4000, it is possible to download a configuration set and a copy of the application code without actually placing them in operation; during this “Pending Reboot” state the CM continues to operate without interruption using the previously executing application code and configuration. Only when the board is rebooted will the new set and application code be placed in use.
The purpose of this technique is to provide the operator better control of system downtime. The download process, which may be rather lengthy in large systems, does not interfere with normal operations. This allows the Reboot step, which is much shorter (but will interrupt switching operations), to be scheduled at an appropriate time.
set selected for editing
CM 4000
Copy of Application (executable code)
Figure 5−11.

Figure 5−12.
When a configuration set is activated, the CM 4000 running 7.0 software will download the configuration and the ap- plication code as a background task. It is important to note that this newly activated configuration and code is not placed in operation on the CM 4000 until a reboot of the processor is performed.
The system will compare the configuration set just downloaded with the configuration set that is in operation; if they are different the “Pending Reboot” message will appear in the “Configuration” column as shown in Figure 5−13. Like- wise the system will compare the application code just downloaded with the application code that is in operation; if they are different the “Pending Reboot” message will appear as shown in Figure 5−14.
Configurator


Copy of Application (executable code) Downloaded
Reboot Reboot “CONFIGURATION PENDING REBOOT”
is indicated when these two sets do not
Figure 5−13.

Copy of Application (executable code) Downloaded
“CODE PENDING REBOOT” is indicated when
Figure 5−14.


Figure 5−15.
The “OK” message means that the set/code executing are the same as the set/code on the file server.
Please refer to Figures 5−16 and 5−17.
Under certain conditions, it is possible for the set/code downloaded (or selected for download) to be different than the software that is actually in operation. An example of this condition is “Pending Reboot” (already described), where a set and application are downloaded for Reboot at a later time.
A similar situation may arise if there is a controller board changeover, a selective download, or a break in the network. The “Mismatch” indicator will show when the set/code in the file server is different than the set/code that is executing in a CM 4000. It is normal for the “Mismatch” indicator to appear while files are being downloaded from the file server to a controller board. The progress and state of the download can be observed by clicking on the “TFTP Status” tab in the Control Center. Once the download is complete, the “Mismatch” indicator will change to “Pending Reboot.” If the “Mismatch” indicator ap- pears (and remains on), and a file transfer is not in progress, it is suggested that steps be taken to reboot the controller.
Configurator · Mismatch Indicator

Figure 5−16.
“CODE MISMATCH” is indicated when these two applications do not match
Copy of Application (executable code)
MISMATCH” is indicated when these two sets do

Figure 5−17.

— “00,” “01,” or “FF” remain indicated on the front panel LED display. Red Alarm light on controller board
remains On. The meaning of the various possible LED on/off combinations is shown in Appendix R.
— The “Device not connected” message fails to appear or clear. There may be a download fault in the CM 4000
serial control section. It may be possible to correct this by resetting the board manually. See Appendix B.
— A switcher control panel fails to indicate switcher status. There may be a download fault in the controller
board. It may be possible to correct this by resetting the board manually. See Appendix B.
— Other errors/conditions. The “TFTP Status” and “Board Info/Control” tabs in the Control Center window can
be used to check the system. For more information, see page 9−1.
— A Log Viewer is also available as a diagnostic tool. For more information, see Section 12.
If a control panel locks up, normal operation can usually be restored by cycling the power to the panel or to the controller board. For additional information concerning hardware reset, please refer to Appendix B.
To uninstall the Jupiter software, follow the procedure given in the Field Engineering Bulletin supplied with the software.
Refer to the Field Engineering Bulletin supplied with the software.
As part of a troubleshooting procedure, you may want to send a particular configuration set to Grass Valley Technical Support for analysis. The Zip tool can be used to assemble all directories and files within a set so that it can be sent as a single com- pressed file.
To zip a set, click on the “Tools > Zip Configuration Edit Set” menu selection. You will be asked to select a configuration set, then you will be asked for the location to store the file. The default location is “C:\Program Files\Thomson\Jupiter\Logda- ta\”. You may wish to change this location (i.e., to a floppy). Once you select OK, the selected set will be zipped up.
Configurator

To unzip a set, click on “Tools > Unzip Configuration Edit Set”. You will be asked which file to unzip. Make sure that the selected file is a valid zip file that was created by the method outlined above. Once you select a zip file and click OK, the set will be unzipped. If the set already exists, you will be asked if you want to overwrite the set. If you select OK, the set will be overwritten.
To combine the active configuration set with the editor’s diagnostic information in a single zip file, go to “Tools > Create Support Package.” This file can then be sent to the Technical Services department to help them troubleshoot any difficulties you are having. The support package will include the version of the configuration set that is currently stored on your hard disk (i.e., unsaved changes will not be included). If your configuration set is new and has never been saved, it cannot be in- cluded.
Printer installation was discussed on page 2−36. If you want to print a single table, bring the table’s window to the top of the desktop. Then select the “Print” command button on the bottom of the window.
Two levels of Help are available for the Configurator: “What’s This” Help, whereby the name of a tool will appear when the cursor remains stationary over the icon for that tool, and “Implicit” Help, where a brief explanation of a field’s purpose or requirements will appear along the bottom of the window when the field is selected.
In addition, an Adobe Acrobat version of the manual you are now reading can be accessed by selecting the “Help” pull−down menu. The Acrobat Reader must be installed to view the manual on−line.
Following a power interruption, the Jupiter controller board(s) will reset itself and should be back in operation in a few sec- onds. The controller board uses a combination of flash ROM and battery−protected RAM to maintain programs and user ta- bles indefinitely.
The file server can be disconnected from the LAN without affecting control panel operation. However, if for some reason a controller board requires re−downloading, it will be unable to complete this operation until the LAN is reconnected and the JNS program is running properly.
Configurator

Quick Start tip: You may wish to skip the Password table when you first configure the system. If password levels are needed they can be added later.
The Jupiter passwords are arranged in a hierarchy, with the “99” level password being the equivalent of a supervisor password. Entry of a 99−level password on the main menu (page 5−2) will allow any system operation, including starting the Jupiter software and creating or changing passwords. There must be at least one 99−level password in the system at all times. In Figure 5−18, Boss Bill might have a password of “007007” with a level of “99.”
In addition, a password level can be established for each control panel and each switcher output. Bill’s control panel has an inherent password level of 80 and the switcher output leading to VTR1 has a level of 60. This means that anyone using Bill’s control panel would be able to select a source for VTR1. Notice that the panel could also be used to select a source for QC but not for the Lobby monitor.
Figure 5−18. Jupiter password system.
—— D E S T I N A T I O N S ——

However, Bill can enter his own personal password into his panel (or anyone else’s) and temporarily raise the panel’s level to “99.” A new source could then be switched to the Lobby:
ÇÇÇ
ÇÇÇ
ÇÇÇ
ÇÇÇ
ÇÇÇ
ÇÇÇ
ÇÇÇ
ÇÇÇ
Boss Bill Bill’s control
Figure 5−19. Raising the level of a panel.
Furthermore, the level of a panel can be raised just long enough to make one switch (or until someone logs out of the panel).

When the level of a panel is raised only temporarily, then re−entry of a password will be required for special commands such as protect* and lock,* and for front−panel definition of overrides.* It may also be required for executing an Input Sequence.*
For example, Operator Dave can protect the feed to VTR1 (Figure 5−20). No other panel, regardless of password level, could then be used to change the source: †
Figure 5−20. Protecting an output.
PROTECT
ÇÇ
ÇÇ
Boss Bill Bill’s control
A more rigorous form of protection is lock, where the output must be deliberately unlocked before changing the source for a particular destination (Figure 5−21). Only the panel used to lock the output could unlock the output.†
Figure 5−21. Locking an output.
ÇÇ
ÇÇ
LOCK Boss Bill Bill’s control
* Terms marked with an asterisk are found in the Glossary.
† Except by using supervisory “force unprotect/unlock.” See page 5−26.

Systems are shipped with a password level of 00 for all panels and outputs; therefore any password can initially be used to access all control panel functions.
As shown in Figure 5−9, there is only one table of passwords, and this table is used no matter what configuration set is active or selected for editing. However, the password levels for individual control panels and outputs are stored with individual con- figuration sets.
As explained above, it doesn’t matter which configuration set is selected for editing, since the password table applies to all sets.
Network Description Serial Protocol
Switcher Description Switcher Input Switcher Output
Control Panel Sets F8 MPK Devices
CP Level Set CP Input Set CP Output Set CP Override Set CP Sequence Set CP Category Set
Machines Machine Control Delegation Groups
Status Display Header VGA Status Display
Sequential Path Finding Non−Sequential Path Finding
Figure 5−22. Configuration set table list.
† See Appendix G. § See Appendix H.
CM VGA Options§
99 Figure 5−23.
Guidelines for using the editor are found on page 5−3.

In this example, pressing Enter at this point will create a row for another password. (If left blank, the new row will be deleted automatically when the table is saved.)
Please see page 5−113.
Please see page 5−57.
Force unprotect/unlock is available as a file server utility (page 11−1) and with the VGA Status Display (page 6−140).
Configurator Passwords

Configurator Network Description Table
This table must be used when the following are first installed on the LAN:
Network Description Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
0080CE010100
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Figure 5−24. Network description (example).
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Each board is given a user−specified name up to eight characters in length. The system is told which type it is, and the Ethernet address, in hexadecimal, as shown on the back of the controller chassis. The Ethernet address was furnished by Xerox Corp. and is unique world−wide. If the board is redundant, the address of the second unit is entered.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for devices. Changing the row num- ber of an existing device (by inserting/deleting a new controller board in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clearing Bat- tery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new devices at the end of tables.
† Saturn configuration instructions are described in the Saturn Installation and Operating manual. ‡ Applies only when Software Control Panel is used for machine control. For more information, see Section 7.

Configurator Network Description Table
Because entries on this table are needed on other tables, the Configurator will automatically copy (or offer as a selectable item) the data entered on this “initial entry” table to all “secondary” tables (including Saturn tables). For example, when a CM 4000 is entered, the name chosen will be added automatically to the Serial Protocol table. For more information about automatic table entry, see page 5−3.
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
Guidelines for using the editor are found on page 5−3.

Configurator Network Description Table
JupiterXPress (“Snowbird”) processor SB
Saturn AAP Analog audio processor AA
Saturn AVP Analog video processor AV
Saturn CP Control Panel CP
Saturn DAP Digital audio processor DA
Saturn DVP Digital video processor DV
Saturn HDVP High definition video HD
PC Software control panel suite PC
For the CM 4000 and other system controllers, the address is shown on the back panel.
Use the Backspace key to erase.
Even though they have the same name, the two boards will have different addresses on this table.
A redundant CM 4000 installation is described on page 2−8.

Configurator Serial Protocol Table
The Serial Protocol table must be used when a CM 4000 System Controller is first connected to VTRs, control panels, and other serial control devices. This includes “remote” (third party) switchers.†
This table is also used when a Saturn video processor serves as a connection point for an MPK bus, and/or when a PC acts as a Software Control Panel.‡
Network Description 5−27 Serial Protocol

Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101

Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−25. Serial protocol table (example).
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
The CM 4000 has eight serial ports; each can be set individually.
The columns on the right side of the table show the baud rate setting for each port.
† Some of the functions described in this section may be extra−cost options or may be unavailable. For more information, see
page 1−27. ‡ Applies only when Software Control Panel is used for machine control. For more information, see Section 7.

Configurator Serial Protocol Table
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
Guidelines for using the editor are found on page 5−3.
Baud rates will be selected automatically for some protocols. The possible selections are as follows (NA = not available, Opt = optional, Std = default):
Figure 5−26. Serial protocol selections.

Device type Protocol 1200 2400 4800 9600 19200 38400 115000
GVG200† 200 NA NA Opt Opt Opt Std NA
Ampex† AMP −−
ASCII ASC Opt Opt Opt Std Opt Opt Note 1
DEC† DEC −−
DD (Diamond)† DIM NA NA Opt Opt Opt Std NA
Datatek DTK NA Std NA
Dune† DUN −−
ESbus† ES −−

Configurator Serial Protocol Table

Device type Protocol 1200 2400 4800 9600 19200 38400 115000
ES Control ESC NA Std NA
ES−Control Panel ESCP Opt Std
ESW−Physical ESP Opt Std NA
ES Switch ESW Opt Std Note 1
GVG Horizon HRZ NA Std NA
GVG Native Protocol GNP Opt Opt Opt Std Opt Opt Opt
MPK MPK Note 3 Note 3 NA NA NA Std NA
Nexus NXS NA Std NA
Party Line† PL −−
RKX† RKX −−
Sony† SNY NA Std NA
TCS 1† TCS −−
TCS 2† TC2 −−
Triton TRI NA Std NA NA
TSL−UMD TSL NA Std NA NA
Utah UDI−1B U96 NA NA NA Std NA NA NA
VT_ VT_ Opt Std Opt NA
documentation supplied with automation system. Note 3: Requires special PROMs or control panel settings. See “MPK” notes on page 5−33. †Depending on equipment, some of the functions described in this section may not be available. For more information, see page 1−27.
ASC (ASCII) refers to switcher control using Jupiter ASCII protocol commands originating from an external computer (e.g, an automation system). When used with Diamond production switchers (as described on page 2−60), the baud rate must match the hardware setting on the DD production switcher XBAR port (normally 38400). A technical description of the Jupiter ASCII computer interface protocol is presented in Appendix N.
DTK (Datatek D−2000/2166), HRZ (GVG Horizon), NXS (Nexus), and U96 (9600 baud connection to Utah UDI−1) all refer to CM 4000 boards controlling one or more of these “remote” (third party) routers. When selected, this entry will apply to CM odd−numbered ports only. (Hardware installation of these switchers is discussed starting on page 2−11.)
DEC is a custom protocol.
DIM (Diamond) is the protocol used to return mnemonic information to a DD Series production switcher serial port. The baud rate must match the Diamond hardware setting (normally 38400) (See page 2−60).

Configurator Serial Protocol Table
ES (ESbus) is for controlling a EBU/SMPTE ESbus−compatible VTR.
ESC (ESbus control) is for controlling a “remote” (third−party) routing switcher using the proposed ESbus routing switcher dialect.)
ESCP (ES−Control Panel) is for a JEP−100 Jupiter / Control Panel operating in Serial mode. For more information, refer to the JEP−100 manual, part no. 071 8376 xx.
ESW (ESswitch) This is a simplified version of the ESbus Tributary protocol. This protocol allows a Grass Valley Crosspoint Bus router‡ to be controlled by an Encore control system, automation system, or third−party computer.
ESP (ESbus Physical) is a protocol used for “physical” switching where the control system selects physical inputs and physical outputs on logical levels. (Note: This is not the same as File Server controlled physical switching, as described on page 14−1.) For a description of this protocol, please contact Grass Valley.
GNP (Grass Valley Native Protocol) is used for Jupiter control of a Grass Valley SMS 7000 or Encore control system (which is in turn connected to a routing switcher).
MPK is the “Message per Keystroke” protocol used for all MPK devices, such as CP−3000 series control panels. (For a complete list of MPK devices, see Dev Type on page 5−108.)
Operating a control panel at any baud rate other than 38400 will limit the number of panels per port to one.
For use with a modem, the CP 3000 panel can be equipped with either a 1200 baud PROM or a 2400 baud PROM; other panels allow the baud rate to be set at the front panel. For more information, refer to page 2−62.
SNY (Sony) is for the Sony machine control protocol.
TSL−UMD (TSL) is for Television Systems Ltd. under monitor displays. For more information, see Appendix S.
TRI (Triton) routing switcher protocol. Hardware installation of these switchers is discussed on page 2−13.
VT_ is a custom protocol.
‡ “Crosspoint Bus routers” are listed on page 1−11.

Configurator Serial Protocol Table
The Saturn Master Control Switcher video processor (either digital or analog) can be used as an alternate connection point for an MPK bus. (In Saturn stand−alone systems, it would be the only MPK port available.) Typical uses for the MPK bus include:
An example entry is shown in Figure 5−27. The name of the video processor comes from the Network Description table. To define the processor’s port, select “MPK” and “38400” for the first port pair. All other ports can be left undefined.
Board (CM 1) Protocol 1/2 -
(CM 2) Protocol 3/4 -
(CM 3) Protocol 5/6 -
(CM 4) Protocol 7/8 -
(CM 5) Protocol 9/10 -
11/12 - (CM 6) Protocol
13/14 - (CM 7) Protocol
15/16 - (CM 8) Protocol
UND
UND
UND
UND
UND
UND
UND
(CM 1) Baud 1/2 -
(CM 2) Baud 3/4 -
(CM 3) Baud 5/6 -
(CM 4) Baud 7/8 -
(CM 5) Baud 9/10 -
(CM 6 Baud 11/12 -
(CM 7) Baud 13/14 -
(CM 8) Baud 15/16 -
Figure 5−27.
Serial Protocol

Configurator Switcher Description Table

Switcher VI RV Board #In #Out PLvL Follow Level Driver 3 LI 3 LO Option Audio Level DM 400 MC Off Time
5 MAINROUT CM1 65 65 16 DM400B Enforce DATA
Switcher Description Switcher Input 5−48 Switcher Output 5−55
Figure 5−28. Switcher Description table (example).
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
This table must be used when the CM 4000† is first connected to a distribution switcher.§
Each logical level number of the switcher is given a user−specified name up to eight characters in length, and the system is provided with detailed information about each level.
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27.

Configurator Switcher Description Table
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
Guidelines for using the editor are found on page 5−3.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for levels. Changing the row number of a level (by inserting/deleting a new level in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clearing Battery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new levels at the end of tables. Adding new levels in the middle of the table will also clear all entries in the Switcher Input and Output tables.
Normally one switcher is named, using up to eight characters.
The level name (also called “logical level name”) can also be up to eight characters. All of the following information entered on this menu will apply to this level. Conventional names are “VIDEO,” “LEFT,” “RED,” “GREEN,”etc.
For a Venus “ES 401”§ digital audio switcher with two−level stereo mode hardware settings, there must be an entry for the Left level and another for the Right level; this will allow special stereo mode switching such as Mix and Reverse. If the ES 401 switcher’s hardware is set for one−level stereo mode, or for one−level mono mode, or if a Venus “ES 400” digital audio switcher is being configured, only one entry is needed. For information about setting the Venus hardware, refer to the Venus Installation manual.
If there is more than one Grass Valley Crosspoint Bus router‡ type in the system (such as a Venus plus a Trinix), there are two possible approaches to configuration. The additional switcher can be entered as a named level (or levels) within the main router; however, this will require a unique hardware setting on each level to avoid conflicts (see diagram on page 2−31). Another solution would be to drive the Venus with one CM 4000 and the Trinix with another; this would allow level settings to remain independent (see diagram on page 2−32).
If the CM 4000 is supplied with house reference sync, checking VI will cause switches on this level to start in the house vertical interval. In other words, the level selected on this menu will start switching first; other levels will follow as soon as possible. Priority is normally given to video since audio switches outside of vertical interval are not as noticeable.
§ In this manual, “ES 401 switcher” refers to the AES11 synchronous/asynchronous version of the digital audio switcher
matrix board and its associated components; “ES 400 switcher” refers to the original asynchronous (non−reclocking) ver- sion of the digital audio switcher matrix board and associated components. ‡ “Crosspoint Bus routers” are listed on page 1−11.

Configurator Switcher Description Table
This method of enforcing vertical interval switching applies only to Grass Valley switchers operating on the Crosspoint Bus port of the CM. For “remote serial control” applications, including Triton, VI should be unchecked on all levels.
This box is checked for older model RS−232/422/423 data switchers equipped with DM 400/400A§ Data Matrix boards. Configuration of DM 400/400A Data Matrix boards is described in Appendix L.
Newer model data switchers equipped with DM 400B§ Data Matrix boards use only one level, and the “RV” box is left unchecked (even though “reverse” switching is still taking place).
As explained in detail elsewhere in this manual, the usual procedure is for the machine assignment system to follow the distribution switcher; that is, if a certain VTR is selected for a certain destination, then the associated machine control panel will automatically assume control of that VTR. (See Assigning Machines to Control Panels on page 5−141 for more information.) This menu item determines which level will be used as the reference in making the machine assignment.
The source of these names is the Network Description table (page 5−27).
Each logical level can be controlled by a separate CM 4000.
Redundant CM boards, if any, are ignored on this table. Recall that redundant CM boards have the same logical name.
Using a single CM, one or more Grass Valley Crosspoint Bus routers can be connected to the Crosspoint Bus port.
Triton routers, or certain non−Crosspoint Bus routers, can be connected to a CM 4000 serial port.
§ Type and model of switcher card is shown on front edge of printed circuit board.

Configurator Switcher Description Table
For Venus video switchers, the maximum for one logical level is 1024 in and out.
For Venus audio switchers, where the left and right channels are assigned to different levels, the maximum number of inputs is 512 per level; the maximum number of outputs is 1024 per level. For example, these values would apply to a Venus analog audio switcher configured for stereo operation (the usual case) and to a Venus ES 401 digital audio switcher configured for two−level stereo operation.
For Venus analog audio switchers configured for mono operation, ES 400 digital audio switchers, or ES 401 digital audio switchers operated in 1−level stereo mode or mono mode, the maximum number of inputs and outputs is 1024.
Special entries are required if Output Monitoring is being used (see Appendix O).
For Venus DM 400B Data Matrix switchers, the entry for “#In” and “#Out” should be set to the actual number of inputs plus 1 to allow an extra number for the “SAFE” input. For example, if the switcher is 64 x 64, both entries should be “65.” (A DM 400B matrix is always square.) The maximum is 192 in and out.
Mars switchers, which use octal architecture, will require special entries. When the binary driver is used (as described in Step 11 below), then the “#In/#Out” entries are as follows:
Switcher size No. of inputs (as entered on table) No. of outputs (as entered on table)
24 x 8 64 16
For the maximum number of inputs/outputs for remote (third party) switchers, refer to the manual supplied with the switcher.
This is the level address determined by hardware switches on the switcher itself. These are normally set at the factory and rarely changed in the field. Refer to the following list and the hardware manual supplied with the switcher for more information.
A physical level number can range from 1 to 999; however, the maximum number of logical levels is still 96. This num- ber may be reduced according to the number of outputs being controlled. For more information, see page 1−16.
a. Trinix digital video routers are usually factory set to operate as physical level 7.

Configurator Switcher Description Table
b. Apex digital audio routers are usually factory set to operate in “two−level stereo” mode, which permits special stereo mode switching such as mix and reverse. The left level is normally set on the rear panel as level 32. The Right stereo channel is automatically given the same number plus 4. This setting requires configuration of two physical levels, typically Level 32 and Level 36. For more information about these hardware settings, refer to the Apex manual.
c. For Venus switchers, the backplane level select jumpers are usually factory set as follows:
Analog video 1 Serial digital video (standard definition) 7 Serial digital video (high definition) 9
Analog audio left (A1) 2 Analog audio right (A2) 6 Analog audio A3 8 Analog audio A4 12 AES digital audio 32 Applies to all versions and modes of digital audio switchers. AES digital audio (right) 36 Applies only to right channel of ES 401 digital audio switchers operated in two−level stereo mode. Time code (mono) 3 Data transmit 16 Data receive 16 Data (reserved) 20
These level numbers should be confirmed by checking the documentation package supplied with the switcher.
Analog audio stereo level numbers: Selection of mono/stereo mode is determined by a backplane jumper. With this jumper in the Stereo position, the physical level number set by the Level jumper is automatically applied to the Left stereo channel (in this example, Left audio would be physical level “2.”); and, the Right stereo channel is automatically given the same number plus 4 the Right stereo channel is automatically given the same number plus 4 (in this example Right audio would be physical level “6”). Furthermore, stereo operation places restrictions on the physical level numbers that can be used; specifically, the “L4” level jumper cannot be installed. For more information, please refer to the “Backplane Jumpers” section of the Venus Installation Manual.
ES 401 digital audio switcher level numbers: Selection of one− or two−level mode is determined by hardware jumpers and switches: (1) If the “Mono” backplane jumper is On, the ES 401 will operate as a one−level mono 64 x 64. (2) With this jumper off, dip switch settings on the Matrix and Output boards will determine whether the switcher is operated as one−level stereo or two−level stereo.
The default setting is Mono jumper OFF, two−level stereo, which permits special stereo mode switch- ing such as mix and reverse. This setting requires configuration of two levels, such as Level 32 and Lev- el 36 as shown above. Again, the right channel always has the number of the left channel plus 4. For more information about these hardware settings, refer to the Venus manual.

Configurator Switcher Description Table
Note: If non−factory default numbers are used, the following rules should be kept in mind: 1) For analog audio left levels, and for digital audio levels, the binary form of the physical level number cannot have the 4s bit set to 1; e.g., decimal ”2” (binary 00000010) can be used for analog audio left but decimal ”4” (binary 00000100) cannot. This means that the following decimal numbers cannot be used: 4 through 7, 12 through 15, 20 through 23, 28 through 31, 36 through 39, 44 through 47, 52 through 55, 60 through 63, etc. 2) The analog audio right level number must be the left number + 4.
d. Concerto switchers are configured much the same as Venus. For more information, refer to Grass Valley Field Engineering Bulletin 075−0722−00, “Jupiter Crosspoint Bus Control of Concerto Flexframe Routing Matrix.”
e. Triton switchers, when controlled by Jupiter, use a level scheme different than that described in the Triton manual. In Jupiter applications, split switching requires each level to be assigned a different number.
Entries in the PLvL column consist of three digits. The first digit serves only to differentiate the table entry from all other physical levels connected to the CM; the second two digits are derived from the “Router Address” DIP switch [setting on the rear panel. In a typical video/audio/time code application, the first digit could be “1,” while the last two digits would be the Router Address for the chassis. For example:
Video 0010 (decimal 02) 102 Left and right audio 0000 (decimal 00) 100 Time code 1111 (decimal 15) 115
As a convention, it is suggested that all Triton chassis connected on the same MIDI bus use the same first digit. Thus if there were a second “group” of Triton switchers connected on another MIDI bus (and per Jupiter require- ments connected to a second CM), they might have “2” as the first digit in the PLvL entry. For example:
News Video CM2 0010 (decimal 02) 102 News Left and right audio CM2 0000 (decimal 00) 100 News Time code CM2 1111 (decimal 15) 115
Aux Video CM5 0010 (decimal 02) 202 Aux Left and right audio CM5 0011 (decimal 03) 203
In RGB or YUV applications where all three signals must always switch together, the Router Address switches should be set to the same value on each chassis. However, the Switcher Description table has only one row cover- ing all three chassis. For example:
Red 0000 (decimal 00) 100

Configurator Switcher Description Table
In this example, the Green and Blue chassis would also have their Router Address switches set to “0000.”
f. Conventional TVS/TAS square matrix switchers. For these switchers the hardware switches are usually set as follows:
Name of level Physical level no.
Video 1 Left audio 2 Right audio 8 Time code 4
TVS/TAS data matrix forward/reverse level numbers: two levels must be described on the table—a forward level and a reverse level; for TVS/TAS data matrix switchers the levels have different physical level numbers.
g. RKX switchers††. The physical level number can range from 0 to 99. Not supported by Jupiter XPress.
h. Multiple switchers.
An example of a multiple switcher installation is shown on page 2−31.
As discussed in Step 3 above, more than one switcher can be operated by a single CM board; however, this will require a unique hardware setting on each level to avoid conflicts. For example, you could enter a switcher “MAIN- ROUT” with levels 1, 2, and 6; and switcher “NEWSROUT” with levels 3, 4, and 5.
Alternatively, by dedicating a separate CM board to each switcher, the same physical level numbers can be used on different switchers if desired. (See diagram on page 2−32.)
i. Logical level mapping (two logical levels on one physical level).
An example of logical level mapping is shown on page 2−29.
In these systems, the same physical level number can be used on more than one logical level (i.e., on more than one row of the Switcher Levels table). For example, you could enter a switcher “MainRout” with Left Audio on level 2, and with Right Audio also on level 2. This technique can sometimes help reduce overall switcher size, but it requires special entries to this table and to the Switcher Outputs table as follows:
— the Switcher Levels table must always show the total number of outputs for the entire physical level. For the
example system shown on page 2−29, the matrix entry would be “60 x 60” for the Left logical level, even though the level is being used as a 60 x 30. The same applies to the Right logical level; the table entry would be “60 x 60.”
— the Switcher Outputs table (page 5−55) must indicate the differing physical output numbers used on each
level. For example, output “VT01” might use physical output “20” for video and left audio and physical out- put “21” for right audio.
††When an RKX and a Grass Valley Crosspoint Bus switcher are entered on this table, an offset of 100 can be used to avoid
having the same level numbers for both switchers. See also footnote marked with “†” on next page.

Configurator Switcher Description Table
j. Datatek D−2000/2166†. The physical level number can range from 0 to 6.
k. ESbus switchers§. The physical level number can range from 0 to 254 (but is limited to 96 by the CM 4000).
l. Nexus†. The physical level number is 0.
m. Utah Scientific† switchers. The physical level number can range from 0 to 3.
On the CM crosspoint bus, this would allow a combination of TVS protocol on some levels and Binary protocol on oth- ers. This would be the case in a system which combines a Venus with a TVS/TAS−2000, for example.
For switchers where split switching is not desirable (such as RGB switchers), this entry can be used to force one level to follow another; for example, “Red” could be entered in the Follow Name box on the menus for the Green and Blue levels. (This entry is not needed for Triton RGB/YUV applications.)
† When a switcher of this type and a Grass Valley Crosspoint Bus switcher are entered on this table, an offset of 100 can be
used to avoid having the same level numbers for both switchers. Thus a hardware level setting of “0” on the Alpha Image switcher could be entered on this table as “100”; or, a hardware Level setting of “1” on the Datatek switcher could be en- tered on this table as “101.” This eliminates the need to re−set existing level settings on the hardware. § When a switcher of this type and a Grass Valley Crosspoint Bus switcher are entered on this table, an offset of 400 can be
used to avoid having the same level numbers for both switchers. See also preceding footnote.

Configurator Switcher Description Table
Figure 5−29. Switcher protocol selections.

Grass Valley Series 7000 (controlled via SMS 7000) GVG Native Protocol
†Not supported by Jupiter XPress application.

Configurator Switcher Description Table
For Triton switchers, select an “A” for each audio chassis. Triton data switchers with rear−panel DIP switch 7 DOWN (“controlled as audio”) also require an “A” entry. For Triton video switchers, or for Triton data routers with switch 7 UP (“controlled as video”), leave the column blank.

Configurator Switcher Description Table
(“Normal/Advise/Enforce”)
Normally, a distribution switcher allows an input to be sent to more than one output. For example, the video in Figure 5−30 could be switched to two destinations at the same time.
Figure 5−30.
In a data switcher, it may be desirable to restrict operation to “point−to−point” switching. For example, this would insure that the transmit data from an editor could be switched to only one VCR at a time, as shown in Figure 5−31.
Figure 5−31.
VCR 2

Configurator Switcher Description Table
When “Enforce” is turned on, and an attempt is made to switch control to a new device, then the device presently being con- trolled will be switched automatically to a “safe” (non−existent) input (Figure 5−32).
Figure 5−32.

VCR 2
The control device would then be switched to the new destination (Figure 5−33).
Figure 5−33.

VCR 2
— For Venus DM 400/400A data routers, the Safe Input is defined as the first input listed on the Switcher Input
table (page 5−52), which is the same as “logical input 1.” The physical input number of the Safe Input should always be “192;” this insures that the router will tri−state (i.e., the destination will be connected to a high−impedance source).
— For DM 400B data routers, the Safe Input is defined as whatever input is named “SAFE” on the Switcher
Input table (page 5−52); the physical input number should always be one (1) beyond the last input number (e.g., if the inputs are numbered 000−063, then the Safe Input would be 064). In these systems selecting the Safe Input will cause the destination to be switched “off.”
When “Advise” is turned on and an attempt is made to switch control to a new device, the switch will not occur. The system will display the following message on the control panel:
Input currently in use by
The operator can then switch the “safe input” to the device presently being controlled. This will avoid having the control de- vice connected to two machines at the same time.
When “Normal” is turned on and an attempt is made to switch control to a new device, the switch will occur immediately. There will be no notification of conflict or extra switch to a safe input.

Configurator Switcher Description Table
Number of frames switcher will dwell on Safe input when switching between controlled devices
When a switch occurs from one VTR control cable to another where the VTRs are of different types, the switch can occur so rapidly that the editing system may not know that a new type of VTR has been connected. This can result in editing inaccuracies since the editing system may be using ballistics for the wrong type of VTR. See Figure 5−34.
Figure 5−34.
VTR 2
To avoid this problem, the data switcher can be set to switch to a Safe input, wait for a specified minimum number of frames, and then switch to the new device. This will cause the editing system to send a request to the new VTR to identify itself and get the correct ballistics.
The wait period is set in the “DM 400 Off Time” column of the Switcher Description table. A setting of approximately 3/4 second is recommended (20 frames). The maximum value is 99 frames.
The delay will only occur when a data switcher is switching real devices, and only when Enforce (see page 5−46) is turned on.
The DM 400A data switcher requires a two−row entry on the Switcher Description table; in this case the DM 400 Off Time entry is made on the Reverse switcher row (the row with the letter “R” in the RV column).
For an overview of data switching, see page 2−30.
“Safe input” · Editor · Data Switcher

Configurator Switcher Input Table
The switcher input table must be used to assign a logical name to each physical input.
If there is more than one switcher in the system, a table must be defined for each. Figure 5−35 shows a table for switcher “MAINROUT.”
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input Switcher Output 5−55
Switcher Input − MAINROUT
LEFT TC
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
000 I 000 I 000 I
2 TONE
000P
000P
3 TC
000P
4 VT01
5 VT02
VT03
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
VT05 005
Status Display Header 5−150 VGA Status Display 5−151
064P
000 I 060 I 060 I
Exclusion 5−188 Y Line 5−189
Figure 5−35. Switcher input table (example).
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
“BARS,” “TONE,” and “VT01” are logical names for various inputs. Each name, which can be up to eight characters long, corresponds to a switcher physical input number for each level of the switcher. This number is normally attached at the factory to each connector on the back of the switcher; however, it should be understood that the real source of this number is the hardware device address, which is usually set with an internal DIP switch or jumper. (For more information, refer to the manual supplied with the particular switcher.)

Configurator Switcher Input Table
Note: an input name is not entered directly at switcher control panels; rather, it is linked to a category and entry number through the CP Input Sets table. The category and entry number are then entered at the control panel to make the switch. The status mnemonic that appears on control panels is also determined by the CP Input Sets table. For more information, see page 5−62.
In Figure 5−35, there are four levels: video, left audio, right audio, and time code. The table shows that the input named “VT01” is wired to connector 001 on all four levels. Similarly, the input name BARS is associated with connector 000 on all four levels.
If there is no entry for a particular level, no switch will occur on that level. On this table, when input “TC” is requested from a control panel, only the time code level will switch.
An automatic split (breakaway) can also be arranged. In this example, a request for the input named “TONE” will obtain input 064 on the video level but input 000 on the other levels. Split switching is described in more detail below.
In Venus DM 400B data switching applications, the switcher input table is used to assign a logical name to each physical port connected to a “tributary” device. For more information, see page 5−52.

Configurator Switcher Input Table
Split (or breakaway) switching is the selection of one input on one level and another input on another level. An example would be the selection of color bars on the video level and test tone on the audio levels. Split switches can be manual, where the operator addresses individual levels and makes each switch separately; or, automatic, where a single category / entry number will cause the split to occur.
An automatic split can be arranged in either of two ways:
— The switcher can be wired so that the split sources arrive on parallel inputs, as shown in Figure 5−36. On the
video level, color bars are wired in as input 0. However, on the audio levels, test tone is wired in as input 0 and a time code generator is wired in as input 0 on the time code level. The Switcher Inputs table (Figure 5−35) is then arranged so that the input named “BARS” will switch to input 0 on all levels. This technique might be referred to as a “hard−wired split.”
Figure 5−36. Inputs to four−level switcher, showing a “hard−wired split.”
BARS
TONE TONE
GEN
1 2 3 4
0 1 2 3 4 0 1 2 3 4 0 1 2 3 4
Right audio Time code
— A more flexible approach is to modify the Switcher Input table so that a single input name will address differ-
ent physical inputs from one level to another. For example, the switcher could be wired as shown in Figure 5−37, where black burst is input 64 on the video level, test tone is input 0 on the audio levels, and a time code generator is input 0 on the time code level. The Switcher Input table is arranged so that the input named “TONE” will switch to those inputs.
Figure 5−37. Software−controlled split.
BLACK
TONE
TONE
GEN
63 65 66 0
1 2 3 4 64 0
1 2 3 4 0
1 2 3 4
Statusing for split switches is determined by the “I” and “P” suffixes on the Switcher Inputs table, as described in Primary and Indirect Status Instructions on page 5−64.

Configurator Switcher Input Table
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
If the table is based on the factory−supplied “Numeric” set, the table illustrates the reason for the name “numeric”—the “Name” column shows all the inputs with numbers instead of names.
Guidelines for using the editor are found on page 5−3.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for sources. Changing the row num- ber of an existing source (by inserting/deleting a new input in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clearing Battery−Pro- tected Memory” in Appendix B). One way to avoid this interruption is to add new inputs at the end of tables.

Configurator Switcher Input Table
In Venus DM 400B data switching applications, the switcher input table is used to assign a logical name to each physical port connected to a “tributary” device. See Figures 5−38 and 5−39.

VTR 1 selected as switcher INPUT
VTR 2 selected as switcher INPUT Figure 5−38. Example of DM 400B system.

4 Figure 5−39. Switcher Input table for system shown in Figure 5−38.
Similarly, the switcher output table is used to assign a logical name to each physical port connected to a “controller” device. See Figure 5−40.

Figure 5−40. Switcher Output table for system shown in Figure 5−38.
Editor selected · as switcher

Configurator Switcher Input Table
Some VTRs can themselves act as controllers or tributaries. With the DM 400B the associated ports can be configured as both inputs and outputs; this allows their pinouts to adjust automatically depending on which VTR is selected as the output (con- troller) and which is selected as the input (tributary). In Figure 5−41, VTR 1 is the controlling device; accordingly it is selected as a switcher output in order to configure the switcher port correctly. The tributary VTR 2 is selected as a switcher input.

VTR 1 selected as switcher OUTPUT
VTR 2 selected as switcher INPUT
Figure 5−41.
In Figure 5−42, the roles are reversed. VTR 2 is the master and VTR 1 is the slave. The switcher ports are configured properly by selecting VTR 2 as an output and VTR 1 as an input.

VTR 1 selected as switcher INPUT
VTR 2 selected as switcher OUTPUT
Figure 5−42.
Examples of Switcher Input and Switcher Output tables for this reassignment application are shown in Figure 5−43.

Configurator Switcher Input Table
Switcher Input − MAINROUT
LEFT TC
DATA
SAFE
VT01
001
Figure 5−43. Switcher Input and Output tables for application shown on page 5−53.
Switcher Output − MAINROUT
LEFT
RIGHT
TC
VT01
2 VT02 − 002 002 002 002
CP Input and Output Sets and Control Panel Operation
The input and output names in the previous tables must be assigned to Category/Entry selections using a CP Input Set (page 5−62) and CP Output Set (page 5−78). For example, if a CP−3000−type panel is to be used, the “C” (for “controller”) category button could be used to select the controller (output) and the VCR category button could be used to select the VCRs .

Configurator Switcher Output Table
The Switcher Output table performs much the same function as the switcher input table (described on page 5−48) except that it applies to outputs.
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output

Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Figure 5−44. Switcher output table (example).
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Name The table is used to give each physical output a logical name up to eight characters in length. If more than one switcher is in the system, a table must be defined for each. Figure 5−44 shows a table for switcher “MAINROUT.”
Unlike the Switcher Inputs table, the outputs table has several provisions for security:
Security A Security Board can be identified for an output by entering the name of a controller board (such as
“CM1”); only controls connected to that board could be used to switch the output. The name must be one of those already entered on the Network Description table (page 5−27).

Configurator Switcher Output Table
S−T A Security Board Type can be entered. Only controls connected to a control board of that type could then
be used to switch the output. A dash (“−”) entry means “none.” The board types that can be selected are “VM” and “SI.”
Pass word A password level can be entered for the output. This is described in detail below.
In Venus DM 400B data switching applications, the switcher output table is used to assign a logical name to each physical port connected to a “controller” device. For more information, see page 5−52.
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for destinations. Changing the row number of a destination (by inserting/deleting a new output in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clear- ing Battery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new outputs at the end of tables.

Configurator Switcher Output Table
In addition to individual Jupiter passwords assigned to each user, individual switcher outputs can be given a password level. This can be used to provide varying levels of protection from one switcher output to another.
To change the password level for a switcher output:
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
In this example, the password level column is blank, meaning that all outputs have a password level of zero. Therefore all passwords presently assigned will allow changing the signal being sent to any output.
Entering a level of “50” would mean that only passwords having levels of 50 or more could be used to enable selection of an input for this output.
Guidelines for using the editor are found on page 5−3.

Configurator CP Level Set

Figure 5−45.
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
CP Level Set — KXYZ−LVL
Level set Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Mnemonic Level Break Switch
LEFT LEFT (MAINROUT)
RGHT RIGHT (MAINROUT)
4 TC TC (MAINROUT)
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Figure 5−46.
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
The CP Level Set table is used to assign levels to control panels. In most cases, control panels are allowed to control all levels, but creating multiple CP Level Sets allows restricting control to certain levels. Level Sets are assigned to individual control panels on the MPK Devices table (page 5−107).
Selecting “Control Panel Sets” on the configuration set table list (Figure 5−22 on page 5−25) will open a dialog similar to that shown in Figure 5−45. This dialog can be used to create, open, copy, and delete Control Panel sets. A example of a com- pleted CP Level Set table is shown in Figure 5−46.
When creating a name for a Jupiter set, it’s a good practice to use letters and numbers only. If you want to use punctuation or special characters, check the list on page 5−7 before creating a name.
When creating a new set, you will asked for the set type: “CP 3000” (for four−character display panels), or “CP−3800” series (for most eight−character display panels).

Configurator CP Level Set
Mnemonic The Mnemonic column of this table is the source for the ID of each level that will appear on control panels during input selection.
Level The Level column determines the order in which the switcher levels will appear in the control panel status display. Video is normally listed first. In the example shown in Figure 5−45, the order from left to right will be video, left audio, right audio, and time code. The first level entered will also be the level statused where display space is limited; e.g., video will be the level statused on the CP 3000 expansion panel.
The source for the switcher Level names is the Switcher Description table (page 5−35).
Break Using the Break column, breakaway switching can be disabled on a level by level basis. Since the CP Level Set can be assigned to individual control panels on the MPK Devices table (page 5−107), this can be used to restrict breakaway switching to specific panels.
Switch Using the Switch column, all switching can be disabled on a level by level basis; and, by CP Level Set assignment, on an individual control panel basis. Status will continue to be shown for the level.

Configurator CP Level Set
ASCII protocol switching instructions include specification of output, input, and level; with level indicated by a number from 1 to 7. These level numbers correspond to the order in which levels are listed on the CP Level Set table. In the example table shown in Figure 5−46, the ASCII level numbers would apply to the switcher levels as follows:
Level number used Example level shown on with ASCII protocol CP Level Set table (Fig.5−45 )
Do not confuse these ASCII level numbers with the logical and physical level numbers of the switcher, which may be differ- ent. (The level names on this table are translated to logical and physical level numbers on the Switcher Description table, as shown on page 5−35.)
For more information about ASCII protocol, see page 2−88.

Configurator CP Level Set
This page intentionally left blank.

Configurator CP Input Set
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Input Set — KXYZ−INP
Category Entry Mnemonic Logical
Test 1 BARS BARS
Test 2 TONE TONE
Test 3 CODE TC
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
VTR 2 VT02 VT02
Status Display Header 5−150 VGA Status Display 5−151
VTR 4 VT04 VT04
VTR 5 VT05 VT05
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−47. CP Input Set (example showing new Auto Mnemonic column).
The CP Input Sets are used to link particular category / entry numbers, and mnemonics, to switcher input names. CP Input Sets are also used to assign an input to each source button on CP 3832 and CP 3864 Control Panels.
† If you want to create a custom category set, skip to CP Category Set (page 5−101) and then return to this subsection.

Configurator CP Input Set
In the example shown in Figure 5−48, selecting VTR/1 on a control panel will call for the input named “VT01.” The system will look on the Switcher Inputs table for this input name and switch to the indicated inputs; in this case, input 001 for all four levels. The mnemonic “VT01” will be used in the control panel status windows to report the switch.

Figure 5−48. Selection of Category/Entry “VTR/1” will switch to input 001 on all four levels.
The Input Sets are assigned to specific control panels on the MPK devices table (page 5−107).
Although each control panel can be assigned a different CP Input Set if desired, the same set is usually assigned to all panels. Different Output Sets, on the other hand, are often used to control access to outputs on a panel−by−panel basis as described on page 5−78.
In Venus DM 400B data switching applications, a CP Input Set is used to assign a category/number and mnemonic to each “tributary” (such as a VTR). For more information, see page 5−52.

Configurator CP Input Set
While the Switcher Inputs table has provision for only one mnemonic per input name (page 5−47), split switching requires a different mnemonic for each device selected.
For example, the top portion of Figure 5−49 shows a four−level switcher with a black burst generator connected to input 64 of the video level, a test tone generator connected to input 0 of the audio levels, and a time code generator connected to input 0 of the time code level.
All of these devices are assigned to the single input name “TONE” on the Switcher Inputs table (as shown at [1] ).
The input named TONE is in turn assigned to the command “TEST 2” (this link is shown by the dotted line [2] ). Without further instructions, the mnemonic for all levels would be “TONE” [3]. However, you might prefer to have “BLK” as a mne- monic for video and “TC” as a mnemonic for the time code level.
To get the mnemonic “TC” on the time code level, an “I” (Indirect) suffix is entered back on the Switcher Inputs table at [4]. This tells the system to search that level for the “P” (Primary) suffix for that input. This is found at [5]. This Primary entry is associated with the input named “TC”[6], which in turn is linked to the mnemonic “TC” [7].
A similar technique is used to get the mnemonic “BLK” on the video level.

Configurator CP Input Set
BLACK
TONE
TONE
GEN
1 2 3 4 64 0
1 2 3 4 0
1 2 3 4
Switcher Input − MainRout
Name VIDEO LEFT RIGHT TC
1 BARS 000 000I 000I 000I 2 TONE 064I 000P 000P 000I 3 TC 000P 4 VT01 001 5 VT02 002 6 VT03 003 7 VT04 004 8 VT05 005
Input Set — KXYZ−INP
Auto Logical Category Entry Mnem Mnemonic Input
1 Test 1 BARS BARS 2 Test 2 TONE TONE 3 Test 3 TC TC 4 VTR 1 VT01 VT01 5 VTR 2 VT02 VT02 6 VTR 3 VT03 VT03 7 VTR 4 VT04 VT04 8 VTR 5 VT05 VT05
Figure 5−49. Primary and indirect status instructions (see notes on page 5−64).

Configurator CP Input Set
(Includes procedure for assigning category/numbers or mnemonics)
For more information, please see Modifying and Downloading a System Configuration Set on page 5−8.

Figure 5−50. Select CP Input Set menu.
You can also double−click on the name of an existing set to open the table.
If you want to copy an existing CP Input Set for use with a different panel type, you can probably save a lot of time by following the procedure described on page 5−77.
Guidelines for using the editor are found on page 5−3.

Configurator CP Input Set
If you want to use a factory default category set (as shown on pages 5−68 and 5−69) leave the Category Set as “Default.”
If you wish to associate an existing Input Set with a different category set than the one originally assigned, see page 5−105.
CP320 CP328 CP2002B CP3000 CP3008† CP3310 CP3800 CP3808 CP3824 CP3830 CP3832 EMEM MC3020L† SATRN† SERIAL UMD3A
Figure 5−51.
† Not supported by Jupiter XPress application..

Configurator CP Input Set
Input Set — KXYZ−INP
Category Entry Mnemonic Input
Test 1 BARS BARS
Test 2 TONE TONE
Test 3 CODE TC
VTR 2 VT02 VT02
VTR 3 VT03 VT03
VTR 4 VT04 VT04
VTR 5 VT05 VT05
MISC 8 ESS ESS
Figure 5−52. Input Set menu (example).
— Adding a new entry, click on the row number above where you want the new entry to appear. Click the “Edit”
pull−down menu. Click on “Insert” and make the addition. Then go to Step 9 through 13 below as appropriate.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for destinations. Changing the row number of a destination (by inserting/deleting a new output in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clear- ing Battery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new outputs at the end of tables.
— Editing an existing entry, click on the item you want to change. Then go to Step 9 through 13 below as
appropriate.
a. Select the desired Category from the pull−down menu. Then press TAB.
The 20−category factory default set used for CP 2002, CP 3000, and CP 3800 panels is as follows:
VTR CG NET SAT A VCR CAM REM EJ** B FILM PTCH STU FS C AUX TEST MISC SS D **EMER on CP 3800
Auto Mnem · Logical · n

Configurator CP Input Set
b. Specify the desired Entry (unit) number. This can be done by clicking on the desired “Entry” field and typing in the number. Press ENTER.
Guidelines for using the editor are found on page 5−3.
Note: For an input that is heavily used, an entry number of zero can be specified to help speed up control panel operation. For example, by assigning color bars as “Test 0,” the mnemonic for color bars will ap- pear immediately on the control panels whenever “Test” is selected; the operator can then complete the switch by pressing Take. However, for this to work properly the zero entry must appear in this table before all other entries for that category; for example, “Test 0” must appear before “Test 1,” “Test 2,” etc.
c. Select the Input name.
The source for the input names is the Switcher Input table (page 5−48).
d. Check the Auto Mnemonic box or enter the desired Mnemonic.
The Auto Mnemonic function can be used to enter a control panel mnemonic automatically based on the Name given to the input. In cases where the input Name is more than four characters long, the mnemonic will be truncated to the first four characters.
If an input Name is changed on the Switcher Input table and Auto Mnemonic is enabled, the mnemonic will change to the new name automatically.
CP 3000 panel mnemonics are limited to four characters.
When finished, skip to Step 15.
a. Enter the desired Category. This can be done by double−clicking on the appropriate field in the Category column; this will open a pull−down menu of categories. Click on a category and press ENTER.
The 16−category factory default set used for the CP 3808 panel is as follows:
VTR CAM SAT EJ VCR NET REM FILM Studio MISC AUX FS CGEN TEST PTCH STILL
The 16−category factory default set used for CP 320 and CP 328 panels is as follows:
VTR CG NET VCR CAM AUX EJ SS REM FILM PTCH STU TEST SAT FS MISC

Configurator CP Input Set
The 15−category factory default set used for CP 3824 panel is as follows:
VTR CG NET VCR CAM AUX SS REM FILM PTCH STU TEST SAT FS MISC
The 12−category factory default set used for the CP 3830 panels:
VTR GFX Studio ENG REM NET EC POST Xmsn AUX TEST NUM
Guidelines for using the editor are found on page 5−3.
b. Specify the desired Entry (unit) number. This can be done by double−clicking on the desired “Entry” field and typing in the number. Press ENTER.
c. Enter the desired Mnemonic.
A CP 320 panel can display four−character mnemonics; the CP 328, CP 3808, CP 3824, and CP 3830 can display eight−characters.
d. Enter the Input name.
The input name will be a name already entered on the Switcher Input table (page 5−48).
When finished, go to Step 15.

Configurator CP Input Set
For DD applications, both E−MEM and Serial tables will probably be required. The dual entries are necessary because of the two hardware connections, as previously described (page 2−60).
For the E−MEM table, you will need entries similar to that shown in Figure 5−53.
Input Set — DIA−INP
Category Entry Mnemonic Input
dflt 1 BARS BARS
dflt 2 TONE TONE
dflt 3 TC TC
Data in this field is not used, but an entry must
dflt 4 VT01 VT01 4
be made to satisfy the Jupiter compiler. Each number in this column must be unique.
dflt 5 VT02 VT02
dflt 6 VT03 VT03
dflt 7 VT04 VT04
dflt 8 VT05 VT05
Figure 5−53. Input Set menu (example).
dflt n ESS ESS
a. For Category, the word “dflt” is used for all entries.
There are no category choices since the DD identifies inputs and outputs by number only.
b. Enter an Entry number. This can be done by double−clicking on the desired “Entry” field and typing the number. Press ENTER.
c. Enter the desired Mnemonic for the first router input that will be available to the DD.
This is the source of the mnemonics that will appear on the DD. The DD can display four−character mnemonics.
d. Select the Input name of the first router input that will be available to the DD. The source of these names is the Switcher Input table (page 5−48).
When a switch is made, Jupiter will search this table for the name of the new input. The corresponding mnemonic will then be sent to the DD.
e. Enter the next Entry number, Mnemonic, and Input name, until you have entered all the inputs that you want avail- able to the Diamond.
When finished, skip to Steps 15 and 16. Then return to Step 2 and following and build the DD serial table.

Configurator CP Input Set
For the Serial table, you will need entries similar to those shown in Figure 5−54.
Input Set — ASC−INP
TONE
TC
VT01
VT02
VT03
VT04
7 8 VT05
Figure 5−54. Diamond Serial Input Set menu.
There are no category choices, since the DD identifies inputs and outputs by number only.
a. Specify the desired Entry (unit) number. This can be done by double−clicking on the desired “Entry” field and typing the number. Press ENTER.
Each Entry number corresponds to a button on the DD Aux Bus. The buttons are numbered 0−47.
b. Select the name of the router Input that you want assigned to the first button on the DD Aux bus. The source of these names is the Switcher Input table (page 5−48).
c. Enter the next Entry number and Input name, up to the maximum of 48 rows.
When finished, skip to Step 15.
If you are entering a set for serial control device, a menu similar to that shown in Figure 5−55 will appear.
Input Set — PC−INP
CAM2
Figure 5−55. Serial Input Set menu.
The purpose of the table is to establish a unique “Entry” number for each switcher “Input” name. In Figure 5−55, Entry number “1” is associated with Input name “CAM1.” The Entry number is the number that the serial control device must send to Jupiter. When the Entry number arrives, the software checks this table to find the associated Input name; then the Switcher Inputs table (page 5−48) is checked to find the corresponding physical input number.

Configurator CP Input Set
Note: For Thomson Broadcast Automation systems, it is suggested that you print out this Input Set; you will need this information when setting up the Automation Switcher Initialization menu. The input names entered on the Jupiter Input Set table must be in the same order as they are on the Automation table. Any changes made to one table must also be made to the other.
When finished, skip to Step 15.

Configurator CP Input Set
If you are entering a set for CP 3832 or CP 3864 (including type “L”), a menu similar to that shown in Figure 5−56 will appear. The purpose of the table is to assign a button position (row number) to each switcher “Input” name. In Figure 5−56, button position “1” will be used to select input “CAM1.” Note that destination buttons are defined on a CP Output Set (page 5−78). Exact table entries will depend on the panel and the application, as shown in the following examples.
For Category, the word “default” is used for all entries.

Figure 5−56. Entries for CP 3832 configured as single− bus panel.

Figure 5−57. Entries for CP 3832 configured as “bal- anced split” panel. Balanced number of input/output buttons is determined by output assignments made on the CP Output Set. For details, see page 5−90.

Figure 5−58. Entries for CP 3832 configured as 30 x 2 “unbalanced split” panel. Total number of input buttons vs. total number of output buttons is determined by num- ber of output assignments made on the CP Output Set. For details, see page 5−90.
† Data not used, but entry must be present to satisfy compiler. Each number in this column must be unique.
Input button 30

Configurator CP Input Set

Input button 64 Figure 5−59. Entries for CP 3864 operated as single− bus panel.

Figure 5−60. Entries for CP 3864 configured as 32 x 32 “balanced split” panel. Balanced number of input/output buttons is determined by output assignments made on the CP Output Set. For details, see page 5−90.

Figure 5−61. Entries for CP 3864 configured as 54 x 10 “unbalanced split” panel. Total number of input buttons vs. total number of output buttons is determined by num- ber of output assignments made on the CP Output Set. For details, see page 5−90.
Input button 32

Configurator CP Input Set
Figure 5−62. Entries for CP 3832 (configured as balanced split panel) with 2nd CP 3832 used as source expansion panel.
CP Input Set − 3832−IN
CAM1
CAM2
CAM2
16 default 16 VTR12 VTR12
17 default 17 VTR13 VTR13
48 default 48 VCR12 VCR12 †
17 Input button 16§ Input button 48§
CP 3832 (configured as
The change will apply to all control panels that use the same Input Set. For the system shown on page 5−107, it would affect all panels in the system since all of them use “KXYZ−INP” as the Input Set.
§ When two or more CP 3832 panels are used, button assignments are also determined by order of MPK table entries. See
page 5−128.
† Data not used, but entry must be present to satisfy compiler. Each number in this column must be unique.

Configurator CP Input Set
Copying a CP Input or Output Set for Use with a Different Panel Type
After you have created a CP Input or Output Set for one panel type, you may want to copy it for use with a different panel. For example, you may have a set for CP 3000 panels, and want to use it with a CP 320. You will need to re−enter some of the category/number selections (because of the difference in the number of possible categories), but you can save time by copying the set in order to use the same mnemonics and input names.
Figure 5−63.

Configurator CP Output Set
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set Override set 5−96 Sequence set 5−99 Category set 5−101

Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−64. CP Output Sets (example showing new Auto Mnemonic column).
Category Entry Mnemnonic Output Links category/entry numbers and mnemonics to switcher outputs.
The Output Sets are assigned to specific control panels on the MPK devices table (page 5−107).
Since each control panel can be assigned a different CP Output Set if desired, these sets are usually used to control access to outputs on a panel−by−panel basis:

Configurator CP Output Set
— You may want a control panel in the master control room to have access to all possible outputs. This panel
might be assigned to Output Set “MC−OUT,” which includes a category/number entry for all destinations.
— However, you may want a control panel in a particular department to have access to only a selected number of
outputs. This panel would be assigned to an Output Set (such as “NEWS−OUT”) which has only those outputs listed.
In Venus DM 400B data switching applications, a CP Output Set is used to assign a category/number and mnemonic to each “controller” (such as an editor). For more information, see page 5−52.
Level Set For assigning a CP Level Set to individual outputs (multiple switcher installations)
The Level Set column is used when there are multiple switchers in the system and you want the control panels to control and status more than one switcher. See page 5−94.
Button For assigning expansion panel buttons to individual outputs
CP 3000/3010 − Outputs are normally assigned to the CP 3010 TAKE button dynamically by the operator (see page 6−24). However, by entering an expansion button number from 1 to 160 (8 buttons x 20 pages) in the Button column and appropriate row of the CP Output table (which is in turn assigned to the CP−3000 panel on the MPK devices table—page 5−107), the output will be assigned permanently to the desired button. Such assignments cannot be changed using the panel itself.
Note: If an output is permanently assigned to a CP 3010 button, but that output is later removed from the CP Output table, and the new set downloaded, the CP 3010 will continue to display the name of the output until the output is manually deleted. This is done by selecting an output that is not defined and pressing the appropriate TAKE key on the expansion panel.
CP 3800 − When in Multiple Destination mode, CP 3800 outputs can be assigned to the soft keys dynamically by the operator (see page 6−34). However, by entering a soft key button number from 1 to 80 (8 buttons x 10 pages) in the “Button” column and appropriate row of the CP Output table (which is in turn assigned to this panel on the MPK devices table—page 5−107), the output will be assigned permanently to the desired button. Such assignments cannot be changed using the panel itself.
CP 3809 − By entering a CP 3809 expansion panel button number from 1 to 40 (8 buttons x 5 panels max) in the Button column and appropriate row of the CP Output table, the output will be assigned permanently to the desired button. Note that this CP Output table must be assigned to the main panel (CP 3808 or CP 3830) on the MPK devices table—page 5−107. (Dynamic assignment of outputs, using the front panel, is described on page 6−124. )
CP 3810 − By entering a CP 3810 expansion panel button number from 1 to 80 (8 buttons x 10 display “pages” max.) in the Button column and appropriate row of the CP Output table, the output will be assigned permanently to the desired button. Note that this CP Output table must be assigned to the main panel (such as a CP 3832 or CP 3864) on the MPK devices table. See page 5−110.
CP 3832/3864 − although the CP 3832/3864 can be used to expand sources and destinations for another CP 3832/3864, these panels do not use the “Button” column. Buttons are assigned to outputs by row number. See page 5−90.

Configurator CP Output Set
After you have created a CP Output Set for one panel type, you may want to copy it for use with a different panel. For example, you may have a set for CP 3000 panels, and want to use it with a CP 310. You will need to re−enter the category/number selec- tions (because of the difference in the number of possible categories), but you can save time by copying the set in order to use the same mnemonics and output names.
As another example, you may have a set for CP 320 panels (which can display four−character mnemonics) and want to use it with a CP 328 (which can display eight−character mnemonics). You will need to re−enter the mnemonics, but you can save time by copying the set in order to use the same category/numbers and output names.
The procedure is similar to that already described for a CP Input Set (see page 5−77).

Configurator CP Output Set
(Includes procedure for assigning category/numbers or mnemonics)
For more information, please see Modifying and Downloading a System Configuration Set on page 5−8.

Figure 5−65. Select CP Input Set menu.
You can also double−click on the name of an existing set to open the table.
If you want to copy an existing CP Output Set for use with a different panel type, you can probably save a lot of time by following the procedure described on page 5−77.

Configurator CP Output Set
If you want to use a factory default category set (as shown on pages 5−84 and 5−85), leave the Category Set as “Default.”
If you wish to associate an existing Output Set with a different category set than the one originally assigned, see page 5−105.

CP310 CP320 CP328 CP2002B CP3000 CP3008† CP3310 CP3800 CP3808 CP3824 CP3830 CP3832 EMEM MC3020D† MC3020L† SATRN† SERIAL UMD3A
Figure 5−66. .
† Not supported by Jupiter XPress.
Create Output Set

Configurator CP Output Set
Output Set — MC−OUT
QC
QC
VTR 1 VT01 VT01
VTR 2 VT02 VT02
4 VTR 3 VT03 VT03
VTR 4 VT04 VT04
Figure 5−67. Output Set table (example).
— adding a new entry, click on the row number above where you want the new entry to appear. Click the “Edit”
pull−down menu. Click on “Insert” and make the addition. Then go to Steps 9 through 15 below as appropri- ate.
Important: Row numbers on Jupiter tables are used as the “logical” numbers for destinations. Changing the row number of a destination (by inserting/deleting a new output in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clear- ing Battery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new outputs at the end of tables.
— editing an existing entry, double−click on the item you want to change. Then go to Steps 9 through 15 below as
appropriate.

Configurator CP Output Set
a. Select the desired Category from the pull−down menu.
The 20−category factory default set used for CP 2002, CP 3000, and CP 3800 panels is as follows:
VTR CG NET SAT A VCR CAM REM EJ** B FILM PTCH STU FS C AUX TEST MISC SS D **EMER on CP 3800
b. Specify the desired Entry (unit) number. This can be done by double−clicking on the desired “Entry” field and typing in the number. Press TAB.
Guidelines for using the editor are found on page 5−3.
c. Select an Output name from the pull−down menu.
The source for these names is the Switcher Output table (page 5−55).
d. Check the Auto Mnemonic box or enter the desired Mnemonic.
The Auto Mnemonic function can be used to enter a control panel mnemonic automatically based on the Name given to the output. In cases where the output Name is more than four characters long, the mnemonic will be trun- cated to the first four characters.
If an Output Name is changed on the Switcher Output table and Auto Mnemonic is enabled, the mnemonic will change to the new name automatically.
Remember that a CP 3000 panel can display four−character mnemonics, while the CP 3800 can display eight−char- acter mnemonics.
e. Optionally, select a Level Set name.
The Level Set column should be used when multiple switchers are in the system and you want the control panels to control and status more than one switcher. See page 5−95.
The source of these names is the CP Level Set tables (page 5−58).
f. Optionally, enter a Button number. This is used to assign Expansion Panel buttons to individual outputs:
CP 3010 Expansion Panel − Outputs are normally assigned to the CP 3010 TAKE button dynamically, by the operator (see page 6−24). However, by entering an expansion button number from 1 to 160 (8 buttons x 20 pages) in the Button column, the output will be assigned permanently to the desired button. Such assignments cannot be changed using the panel itself.

Configurator CP Output Set
Note: If an output is permanently assigned to a CP 3010 button, but that output is later removed from the CP Output table and the new set downloaded, the CP 3010 will continue to display the name of the out- put until the output is manually deleted. This is done by selecting an output that is not defined and press- ing the appropriate TAKE key on the expansion panel.
CP 3800 − When in Multiple Destination mode, CP 3800 outputs can be assigned to the soft keys dynamically, by the operator (see page 6−34). However, by entering a soft key button number from 1 to 80 (8 buttons x 10 pages) in the “Button” column the output will be assigned permanently to the desired button. Such assignments cannot be changed using the panel itself.
CP 3810 Expansion Panel − By entering an expansion button number from 1 to 80 (8 buttons x 10 pages) in the Button column, the output will be assigned permanently to the desired button.
When finished, skip to Step 17.
a. Enter the desired Category. This can be done by double−clicking on the appropriate field in the Category column; this will open a pull−down menu of categories. Click on a category and press ENTER.
The 16−category factory default set used for the CP 3808 panel is as follows:
VTR CAM SAT EJ VCR NET REM FILM Studio MISC AUX FS CGEN TEST PTCH STILL
The 16−category factory default set used for CP 320 and CP 328 panels is as follows:
VTR CG NET VCR CAM AUX EJ SS REM FILM PTCH STU TEST SAT FS MISC
The 15−category factory default set used for CP 3824 panel is as follows:
VTR CG NET VCR CAM AUX SS REM FILM PTCH STU TEST SAT FS MISC
The 12−category factory default set used for the CP 3830 panel is as follows:
VTR GFX Studio ENG REM NET EC POST Xmsn AUX TEST NUM
Guidelines for using the editor are found on page 5−3.

Configurator CP Output Set
b. Specify the desired Entry (unit) number. This can be done by double−clicking on the desired “Entry” field and typing the number. Press ENTER.
c. Select the Output name.
The source of these names is the Switcher Output table (page 5−55).
d. Check the Auto Mnemonic box or enter the desired Mnemonic.
The Auto Mnemonic function can be used to enter a control panel mnemonic automatically based on the Name given to the output. In cases where the output Name is more than four characters long, the mnemonic will be trun- cated to the first four characters.
If an Output Name is changed on the Switcher Output table and Auto Mnemonic is enabled, the mnemonic will change to the new name automatically.
A CP 320 panel can display four−character mnemonics; the CP 328, CP 3808, and CP 3830 can display eight−char- acters.
e. Optionally, enter the Level Set name.
The Level Set column should be used when multiple switchers are in the system and you want the control panels to control and status more than one switcher. See page 5−95.
f. Optionally, enter a Button number.
By entering a CP 3809 Expansion Panel button number from 1 to 40 (8 buttons x 5 panels max) in the Button column and appropriate row of the CP Output table, the output will be assigned permanently to the desired button. Note that this CP Output table must be assigned to the main panel (CP 3808 or CP 3830) on the MPK Devices table—page 5−107. (Dynamic assignment of outputs, using the front panel, is described on page 6−124.)
When finished, go to Step 17.
For these multi−bus control panels, a special CP Output Set is used to identify the outputs that will be controlled by the panel. This set is assigned to the specific control panel with the MPK devices table. In this case, there must still be an entry in each field of the CP Output Set table, even though the only data that will be used is in the Output column. The category name “dflt” is used throughout, but selection numbers and at least one character for a mnemonic will have to be entered on each of the eight (or six) rows in order to satisfy the system compiler.
When finished, skip to Step 17.
For the dual−bus CP 330 control panel, a special CP Output Set is used to identify the two outputs that will be controlled by the panel. This set is assigned to the specific CP 330 with the MPK Devices table. The only data that will be used is in the Output column; however, category names, selection numbers, and at least one character for a mnemonic will have to be entered on both rows in order to satisfy the system compiler.

Configurator CP Output Set
When finished, skip to Step 17.
For DD applications, both E−MEM and Serial tables will probably be required. The dual entries are necessary because of the two hardware connections, as previously described (page 2−60).
For the E−MEM table, you will need entries similar to that shown in Figure 5−68.
Output Set — DIA−OUT
Category Entry Mnemnonic Output Level Set Button Logical
4 dflt 4 DD04
Figure 5−68. Output Set table (example).
128 dflt 128 DD128
a. For Category, the word “dflt” is used for all entries.
b. Specify the desired Entry number. This can be done by double−clicking on the desired “Entry” field and typing the number. Press ENTER.
Note: These Entry numbers must match the numbers assigned to the buttons on the DD M/E Bus, using the DD “Install > Ident Input > Ident Xbar” menu. Each DD button that is fed from the router should be assigned an Entry number from 1 to 128. Refer to the DD installation manual for information about the DD serial ports and operating instructions.
c. Enter the name of the first router Output wired to the DD. The source of these names is the Switcher Output table (page 5−55).
d. Enter the next Entry number and Output name, up to the maximum of 128 rows.
When finished, skip to Steps 17 and 18. Then return to Step 2 and build the DD serial table.

Configurator CP Output Set
For the Serial table, you will need entries similar to those shown in Figure 5−69.
Output Set − ASC−OUT
DD02
DD03
DD04
DD05
6 6 DD06
Figure 5−69. Serial Input Set menu.
a. Specify the desired Entry (unit) number.
Note: These Entry numbers must match the numbers assigned to the six buttons of the DD Delegation Bus, using the DD “Install > Extern Aux > Config” menu. As a convention, these buttons are assigned Entry numbers from 1 to 6. This will allow the DD operator to control up to six router outputs (these router outputs are wired into the DD as inputs). Refer to the DD installation manual for information about the DD serial ports and operating instructions.
b. Enter the name of the first router Output that is wired to the DD. The source of these names is the Switcher Output table (page 5−55).
c. Enter the next Entry number and Output name, up to the maximum of 128 rows.
When finished, skip to Step 17.
Entry · Logical · Output

Configurator CP Output Set
If you are entering a set for a serial control device, you will need a table similar to that shown in Figure 5−70.
Output Set − ALAM−OUT
VT01
VT02
VT03
VT04
6 6 VTO5
VT06
8 8 VTO7
Figure 5−70. Serial Output Set table.
The purpose of the table is to establish a unique “Entry” number for each switcher “Output” name. In Figure 5−70, Entry number “1” is associated with Output name “QC.” The Entry number is the number that the serial control device must send to Jupiter. When the Entry number arrives, the software checks this table to find the associated Output name; then the Switcher Outputs table (page 5−55) is checked to find the corresponding physical Output number.
Note: For Thomson Broadcast Automation systems, it is suggested that you print out this Output Set; you will need this information when setting up the Automation Switcher Initialization menu. The Output names entered on the Jupiter Output Set table must be in the same order as they are on the Automation table. Any changes made to one table must also be made to the other.
When finished, skip to Step 17.

Configurator CP Output Set
If you are entering a set for CP 3832 or CP 3864, a menu similar to that shown in Figure 5−71 will appear. The purpose of the table is to assign a button position (row number) to each switcher “Output” name. Exact table entries will depend on the panel and the application, as shown in the following examples. Note that source buttons are defined on a CP Input Set (page 5−74).
For Category, the word “default” is used for all entries.
Split mode. Split mode operation is determined by the checkmark in the Expansion box in the MPK table (page 5−109). In this application, some buttons are used for inputs and some for outputs. If the number of in- puts and outputs is the same, the split is “balanced” and the panel can be used with expansion panels. See Figures 5−71 and 5−72.

Figure 5−71. Entries for CP 3832 configured as “balanced split” panel.

Figure 5−72. Entries for CP 3864 configured as “balanced split” panel.
† Data not used, but entry must be present to satisfy compiler. Each number in this column must be unique.

Configurator CP Output Set
A split panel can also be configured with a different number of inputs and outputs (“unbalanced split”), but such panels cannot be expanded. In this application, the number of outputs can be from 1 to 15 (CP 3832) or 1 to 31 (CP 3864). Buttons not assigned to outputs are available for inputs. For example, if two buttons are used for out- puts, then 30 buttons will be available for inputs on a CP 3832 panel. See Figures 5−73 and 5−74.
OUT
CP−3832
Output Set — 3832−OUT
Category Entry Mnemnonic Output Lev Set Button Logical
default 1 MONITOR1 MON1
2 default 2 MONITOR2 MON2
Figure 5−73. Entries for CP 3832 configured as 30 x 2 “unbalanced split” panel.
OUT
CP−3864
Output Set — 3832−OUT
Category Entry Mnemnonic Output Lev Set Button Logical
default 1 MONITOR1 MON1
2 default 2 MONITOR2 MON2
10 default 10 VTR−12 VT12
Figure 5−74. Entries for CP 3864 configured as 54 x 10 “unbalanced split” panel.

Configurator CP Output Set
Expansion mode. Unless the panel is operated in “unbalanced split” mode, control of additional outputs is possible using adjacent CP 3832 or CP 3864 panels. See Figure 5−75.
Output Set — 3832−OUT
Category Entry Mnemnonic Output Lev Set Button Logical
default 1 MONITOR1 MON1
2 default 2 MONITOR2 MON2
64 default 64 VTR−12 VT12
65 default 65 VTR−13 VT13 †
OUT
CP 3864
Output button 65§
96 default 96 AUX−12 AX12
Output button 96§
Figure 5−75. Entries for CP 3864 used for destinations and CP 3832 used as destination expansion panel.
§ When two or more CP 3832/3864 panels are used, button assignments are also determined by order of MPK table entries.
See page 5−128. † Data not used, but entry must be present to satisfy compiler. Each number in this column must be unique.

Configurator CP Output Set
The CP 3832/64 can be also be operated in connection with an adjacent CP 3810 Expansion Panel. See Figure 5−76.
CP 3832 (Main panel)
Output Set — 3832−OUT
Entry Mnemnonic Output Lev Set Button Category Logical
2 2 MONITOR2 MON2 2
PAGE
8 8 VTR−4 VTR4 8
PAGE
9 9 VTR−5 VTR5 9
Figure 5−76. Entries for CP 3810 used as multi−destination panel. Set is assigned to main panel on MPK Devices table.
Up to page 10
The change will apply to all control panels that use the same Output Set. For the system shown on page 5−107, it would affect all panels in the system since all of them use “KXYZ−OUT” as the Output Set.
† Data not used, but entry must be present to satisfy compiler. Each number in this column must be unique.

Configurator CP Output Set
Please refer to Figure 5−77 for the following discussion.
When more than one switcher is in the system, and you want to operate the switchers from one control panel, there must be a separate CP Level Set for each switcher ( [1] and [2] ). This is because the CP Level Set is used to determine how status will be shown on the panel; specifically, the first entry on the CP Level Set will be the level that is statused. In this example, video will be statused.
The CP Output Set is used to assign an individual output to a CP Level Set for the appropriate switcher [4]. In this example, all outputs of the “NewsRout”switcher would be assigned to the CP Level Set named “2000−LEV.”
Similarly, all outputs of the “MainRout” switcher could be assigned to a CP Level Set on an output−by−output basis, but in this example the Lev Set entry is blank. With no entry, the system will refer back to the MPK Devices table to locate the default CP Level Set—in this case, “KXYZ−LEV” [3]. Thus the “KXYZ−LEV” table will be used to establish “MainRout” status [2].

Configurator CP Output Set
Figure 5−77. CP Output Set and CP Level Set requirements for multiple switcher installations. See page 5−94 for discussion.

MPK Device Devices Type Exp Pw Mode Board Port Address In Set In Panel Out Set Out Panel Lev Set Over Set Seq Set
1 STUCP CP−3000 L CM1 8 00000014 KXYZ−INP KXYZ−OUT KXYZ−LEV KXYZ−OVE
Auto Logical Category Entry Mnem Mnemonic Output Level Set Button
1 VTR 1 VT01 VT01 [BLANK] 2 VTR 2 VT02 VT02 [BLANK]
VCR 20 VT20 VT20 2000−LEV VCR 21 VT21 VT21 2000−LEV
1 VID VIDEO (NEWSROUT) 2 LEFT LEFT (NEWSROUT) 3 RGHT RIGHT (NEWSROUT)
1 VID VIDEO (MAINROUT) 2 LEFT LEFT (MAINROUT) 3 RGHT RIGHT (MAINROUT)
CM 4000

Configurator CP Override Set
The override function, which allows single−keystroke selection of a source, is used for a quick or emergency switch to an often−used input. For example, the black burst generator could be defined as the first “override” source for the system, corre- sponding to the first soft key position on a CP 3000 or CP 3800 panel. When in a hurry to find black burst, the operator can then press BLK, TAKE (instead of, for instance, TEST, 1, TAKE).
Override sets are also used to assign an input to each button on CP 300, CP 310, CP 330, and CP 3020 Push Button Control Panels, and to the button−per−source keys on CP 3824 panels.
The overrides can be permanently assigned with the file server (as described immediately below), and, if desired, temporarily edited at CP 3000 control panels (as described on page 6−21). Overrides can also be temporarily edited at CP 3800 panels (as described on page 6−54) and CP 3824 panels (page 6−85).
The order in which the overrides are listed on this table will be the order in which they appear on the panels.
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set Sequence set 5−99 Category set 5−101
CP Override Set — KXYZ−OVE
BLK
YYYY
BARS BARS YYYY
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
SLNC SLNC YYYY
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−78. CP override set (example).
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1

Configurator CP Override Set
For more information, please see Modifying and Downloading a System Configuration Set on page 5−8.

Figure 5−79. Override edit set menu (example).
The menu lists all override sets in the configuration set presently selected for editing.
Because they can display eight−character mnemonics, the CP 3800 and CP 3824 all use type “CP3800” override sets.
Select Override Set

Configurator CP Override Set
Guidelines for using the editor are found on page 5−3.
The source of these names is the Switcher Input table (page 5−48).
Although the CP 3824 has only 24 button−per−input keys, up to 360 inputs can be assigned on this table, i.e., 15 groups (“pages”) of 24 inputs each. Each page of 24 sources would then be accessed with the Page key.
For CP 330 panels configured for dual bus control (24 x 2), the first 24 rows on this table will apply to the top row of 24 buttons and the next 24 rows to the bottom row of buttons.
The change will apply to all control panels that use the same override set. For the system shown on page 5−89, it would affect all CP 3000 panels in the system since all of them use “KXYZ−OVR” as the override set.

Configurator CP Sequence Set
A sequence is a switch of one or more sources to one or more destinations.
The CP 3000 panel can accommodate a maximum of 25 events (switches) in one sequence.
There is no specific limit to the number of sequences, but due to memory restrictions a limit of 16 is recommended.
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set Category set 5−101
Sequence Set − KXYZ−SEQ
VT01
PRDA
YYYY
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
PRDB
SEQ1 VC02 YYYY
PRDC
SEQ2 CAM1 YNNN
MON1
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−80. CP sequence set (example).
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
In Figure 5−80, the first three rows show the switching events in “Seq1.” In this example, selecting “SEQ1” will cause three VTRs to be switched into inputs A, B, and C of a production switcher. All four levels (video, audio left, audio right, and time code) will be switched. The switches will take place in the vertical interval at maximum system speed.
Sequences are stored as sequence sets; these sets can be made available to some or all control panels. For the system shown on page 5−89 (on the MPK Devices menu), the set in this example would be available to all CP 3000 Switcher Control Panels in the system since all of them use “KXYZ−SEQ” as the sequence set. Sequences can include outputs not otherwise available to a panel (i.e., when the outputs are not entered on the CP Output Set assigned to the panel).
When operating the CP 3000, sequences are accessed through the Menu and F keys, as described on page 6−17.
Note 1: Data matrixes can be part of sequences when used in conjunction with the “DM 400 Off Time” feature (DM 400 Off Time is described on page 5−47). There should not be more than 25 DM 400 safe off time switches per sequence. Safe off time in sequences must be used with care as specifying too short of a safe off time may result in the switch occurring too soon; this could result in switches occurring out of sequence.

Configurator CP Sequence Set
Note 2: Great care needs to be used to ensure that the switches defined in CP Sequence Sets involving Data Routers do not conflict. Verify that each sequence uses all defined data router inputs and outputs just once, including the implied reverse switches. Failure to do this will result in unintended switches, and possibly switching a single input to multiple outputs at the same time.
For more information, please see Modifying and Downloading a System Configuration Set on page 5−8.
Enter a name for the first sequence.
Select the first input name (source for these names is the Switcher Input table, page 5−48). Select the first output name. The source for these names is the Switcher Output table (page 5−55).
Guidelines for using the editor are found on page 5−3.
The Levels column is edited by double−clicking in the field and toggling the desired levels on or off in a secondary dialog box.

Configurator CP Category Set
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set
Category Set − 3200-CAT
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Figure 5−81. CP category set (example).
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
The CP Category Set table allows the category names to be customized. (Categories are classes of inputs/outputs, such as “VTR” and “CAM.”) This table is the source of the name that appears in the display window when a category key is pressed.
A custom category set can be used with the CP 320, CP 3000, CP 3800, CP 3808, CP 3824, and CP 3830 panels, all of which have re−legendable keycaps.
A CP Category Set is normally assigned to a CP Input Set and to a CP Output Set when those sets are first created. However, this assignment can be changed later if desired (see page 5−105).
The CP Input and Output Sets are in turn assigned to specific control panels on the MPK Devices table (page 5−89).
When creating a new CP Category set, the menu shown in Figure 5−82 will appear.

Configurator CP Category Set

CP310 OUT CP320 IN CP320 OUT CP328 IN CP328 OUT CP2002B IN CP2002B OUT CP3000 IN CP3000 OUT CP3008 IN† CP3008 OUT† CP3310 IN CP3310 OUT CP3800 IN CP3800 OUT CP3808 IN CP3808 OUT CP3824 IN CP3824 OUT CP3830 IN CP3830 OUT CP 3832IN CP3832 OUT EMEM IN EMEM OUT SATRN IN SATRN OUT† SERIALIN SERIALOUT UMD3AIN UMD3AOUT
Figure 5−82. CP category set create menu.
This menu is used to enter the name of the set and select the set type.
When finished, a blank version of the table shown in Figure 5−81 will appear.
Guidelines for using the editor are found on page 5−3.
Each CP 3000, or CP 3800 Category Set can contain up to 20 category mnemonics; if less than 20 categories are entered, the remaining category keys will be inoperative.
† Not supported by Jupiter XPress application.

Configurator CP Category Set
The table entries correspond to the CP 3000 and CP 3800 category keys as follows:
1 2 3 4 5
1 CG
2 NET
3 SAT
A
6 7 8 9
4 CAM
5 REM
B
11 12 13 14 15
7 PTCH
8 STU
9 FS
16 17 18 19 20
0 MISC SS
D
CP 3000/3800 key positions showing number of corresponding
Original CP 3000 engraved keys
Figure 5−83. CP 3000/3800 key positions.
row on Category Set table
Each CP 320 and CP 3808 Category Set can contain up to 16 category mnemonics; if less than 16 categories are entered, the remaining category keys will be inoperative.
The table entries correspond to the CP 320 category keys as follows:
1 CG
2 NET
3 VCR
4 CAM
5 AUX
EJ SS
1 2 3 4 5 6 7 8
6 FILM
7 PTCH
8 STU
9 TEST
MISC FS SAT
9 10 11 12 13 14 15 16 Figure 5−84. CP 320 key positions.

Configurator CP Category Set
The table entries correspond to the CP 3808 category keys as follows:
1 CAM
2 SAT
EJ
1 2 3 4
4 NET
5 FILM REM
5 6 7 8
8 AUX
FS
9 10 11 12
STILL CGEN
13 14 15 16 Figure 5−85. CP 3808 key positions.
Each CP 3824 Category Set can contain up to 15 category mnemonics; if less than 15 categories are entered, the remaining category keys will be inoperative. The table entries correspond to the CP 3824 category keys as follows:
1 CG
2 NET
3 CAM
VCR
1 2 3 4 5
6 SS
7 FILM
REM
9 PTCH
6 7 8 9 10
STU TEST FS MISC SAT Figure 5−86. CP 3824 key positions.
11 12 13 14 15
Each CP 3830 Category Set can contain up to 12 category mnemonics; if less than 12 categories are entered, the remaining category keys will be inoperative. The table entries correspond to the CP 3830 category keys as follows:
1 GFX
ENG
4 REM
5 NET
EC
7 POST
0 AUX
TEST
NUM
12 Figure 5−87. CP 3830 key positions.
Stu · 2 Stu · 8 Xmsn

Configurator CP Category Set
A custom Category Set can be created at any time. The following procedure is used to assign a new Category Set to an existing CP Input Set or CP Output Set.
Figure 5−88. CP set dialog (example).
If you want to return to the factory default category set, leave the Category Set name as “Default.”

Configurator CP Category Set
This page intentionally left blank.

Type Expansion Pass Board
Devices word In Panel Out Panel
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
CM1
2 CM1 KXYZ−INP KXYZ−OUT KXYZ−LEV
STUCP CP−3000 6 00000014 KXYZ−OVE KXYZ−SEQ
ENGCP CP−3000 6 00000013 KXYZ−OVE KXYZ−SEQ 3 CM1 KXYZ−INP KXYZ−OUT KXYZ−LEV
MC CP−3000 2 00000000 KXYZ−OVE KXYZ−SEQ 4 CM1 KXYZ−INP MC−OUT KXYZ−LEV
SHOP CP−3000 2 00000002 KXYZ−OVE KXYZ−SEQ 5 CM1 KXYZ−INP SHOP KXYZ−LEV
DELAY CP−3000 2 00000003 KXYZ−OVE KXYZ−SEQ 6 CM1 KXYZ−INP DELAY−OUT KXYZ−LEV
TAPECP CP−3000 6 00000008 KXYZ−OVE KXYZ−SEQ 7 CM1 KXYZ−INP TAPE−OUT KXYZ−LEV
CONF CP−3000 3 00000006 KXYZ−OVE KXYZ−SEQ 9 CM1 KXYZ−INP CON1 KXYZ−LEV
PROD CP−3020 6 00000012 10 CM1 3020−OVE VT01 KXYZ−LEV
EDIT CP−320 5 00000037 12 CM1 KXYZ−INP EDIT−OUT KXYZ−LEV
Figure 5−89. MPK Devices table (example).
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
This table must be used to define all MPK devices in the system. These include control panels and status displays. It is also used when a PC is used as a Software Control Panel.§
§ Applies only when the Software Control Panel is used for machine control. For more information, see Section 7.

Important: Row numbers on Jupiter tables are used as the “logical” numbers for devices. Changing the row number of an existing device (by inserting/deleting a new control panel in the middle of the table, for example) will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clearing Battery−Protected Memory in Appendix B). One way to avoid this interruption is to add new devices at the end of tables.
MPK Devices This column is used to create a name, up to eight characters in length, for each MPK device in the system. Machine control panels (such as MC 3000, MC 3010, CP 3000 with “Exp” (expansion), CP 3800, and CP 3810) listed here will automatically appear as a selection on the Machine Control table (page 5−139).
Type Device types (shown on a pull down menu) are limited to the following:
CP 300 CP 300/S CP 310 CP 310/S CP 320 CP 320/S CP 328 CP 328/S CP 330 CP 330/6 CP 330/S CP 2002B CP 2002D CP 3000 CP 3008†
CP 3810 (p. 5−131) CP 3810L (p. 5−131) CP 3810S†
MC 3020L †
MC 3040/2 †
CP 3824 CP 3830 CP 3830P †
MC 3040/4 †
MC 3040/8 †
MCS TALY †
CP 3832 CP 3832L CP 3832P †
MESS UMD 3040 LOCK †
3040 SLCT †
CP 3832S †
MI 3040/T MI 3040/2 †
CP 3864 CP 3864L CP 3864P †
MI 3040/4 †
MI 3040/8 †
Diamond (p. 5−123) ES−LAN FCS 3276†
CP 3020 †
CP 3021 †
FCS 3277 †
Serial (p. 5−123) TSL−UMD WPE* UMD3A VC 3020 (p. 5−114) VCP 3000† (p. 5−114) VMC 3000† (p. 5−114)
FCS 3296 †
CP 3310/5 †
FCS 3360 †
CP 3310/8 †
FCS 3363 †
CP 3320 †
GVG 200 †
CP 3300/X †
JNS−UMD MANAGER§ MC 3000 MC 3010
CP 3800 CP 3808 CP 3809
Selecting a control panel with an “/S” suffix will cause the panel to operate with “sticky levels.”*
Selecting a CP 3810L device type will cause the panel to operate in single bus mode. For more information, see page 5−131 and following.
Selecting a CP 3810S device type will cause the panel to operate in “sticky output” mode.
* Defined in Glossary section. † Not supported by JupiterXPress application. § Custom.
Configurator MPK Devices · SD 3x†

Selecting a CP 3832L or CP 3864L device type will cause the right−hand group of six buttons to function as level selection buttons.
ES−LAN applies to the JEP−100 Jupiter / Encore Control Panel. For more information, refer to the JEP−100 manual, part no. 071 8376 xx.
Expansion As a general rule, the Expansion box is checked when the panel is used with an expansion panel; for example, when a CP 3000 is used with a CP 3010. For special uses of this column, see the notes below.
For each MC 3010, there is only one entry whether it is a 4 machine panel (MC 3010/1) or a dual 4 machine panel (MC 3010/2). The right−hand panel of an MC 3010/2 is not treated as an expansion panel; therefore, the Expansion box is not checked.
The CP 3800 panel can be defined for Multiple Destination Mode operation (front−panel selectable to Single Destination mode); or, defined for Single Destination Mode only operation. For front−panel selectable, Mul- tiple or Single Destination Mode operation, the Expansion box is checked. For Single Destination Mode only operation, the box is not checked.
When CP 3808 or CP 3830 control panels are associated with a CP 3809 Expansion Panel(s), the CP 3808/3830 Expansion box is checked. The CP 3809 entry is unchecked.
When a CP 3832 or CP 3864 control panel (including type L) is to be operated as a “split” panel, with some of the buttons used for inputs and some for outputs, the Expansion box is checked. For all other applications, the box is not checked (even when the panel is used in association with another panel to expand the number of inputs or outputs, the box entry is still unchecked). The split mode cannot be combined with the continuous Preset mode described above.
For CP 3810 Expansion Panel(s), the Expansion box is always unchecked.
When a CP 330 is defined with the Expansion box checked and an Output Set with two or more outputs defined, the CP 330 will operate as a 24 X 2 panel with the top row of buttons assigned to one output and the bottom row to another. The first two outputs defined in the Output Set will be the two output buses it will control.
Pass word This table has provisions for entry of password levels (described in detail on page 5−113).
Board Name of controller board connected to this device. The source of these names is the Network Descrip- tion table (page 5−27).
Port Number of controller board port connected to this device. The port must support the necessary protocol for this device (as configured on the Serial Protocol table, page 5−30).
Address Address (hex). Unique serial data bus ID used to select and service this device. Must be entered in hexadecimal. (Not to be confused with LAN address entered on Network Description table shown on page 5−27).
Configurator MPK Devices

With the exception of the CP 3800 Series panels, RP 1/2/3, RP 1/2/3 C, and SlimLine Under Monitor Dis- plays, device addresses such as “00000018” are determined at time of manufacture and cannot be changed by the user. To display the address of a control panel, please see Display Control Panel ID on page 6−21.
Input Sets Name of CP Input Set to be assigned to this device. The usual practice is to have one CP Input Set, containing the names of all inputs, apply to all panels. However, special CP Input Sets could be created which list only selected inputs; such a set could be used to prevent certain panels from selecting specific inputs. Creation of CP Input Sets was described on page 5−62.
If panel “A” does not have access to a certain input, but that input has been selected by panel “B” for the output presently being statused by panel A, then panel A has no way of reporting the mnemonic of the input. Under these conditions, panel A will show asterisks (****) for status.
For each CP 3832 or CP 3864 (including type L) operated as a:
— Single−bus control panel, select the name of the CP Input Set that will be used to assign sources to the control
panel’s input buttons.
— “Split” panel, with some of the buttons used as inputs and some as outputs, select the name of the CP Input Set
that will be used to assign sources to the control panel’s input buttons.
— Main source panel (controlling the inputs at a multi−panel control station) select the name of the CP Input Set
that will be used to assign inputs to the buttons at this control station. See page 5−127 for more information about CP 3832/64 multi−panel control stations.
In Panel This column is used only for expansion panel configuration when that panel will be used for addi- tional inputs.
For each CP 3832 or CP 3864 operated as an expansion input panel (used in association with a main source panel), select the MPK Devices name of the associated main panel in this column. See page 5−127 for more information about CP 3832/64 multi−panel control stations.
Out Set CP Output Set name. Creation of CP Output Sets was described on page 5−78.
If the entry is an actual CP Output Set, then the control panel will be able to control all the outputs listed in that Set. Depending on the contents of the set, this would allow for full−matrix or multi−bus control.
For many single−output panels, this field can be used to enter the name of a single switcher output to be con- trolled (see Note 2 below for exceptions). The source of the output names is the Switcher Output table (page 5−55).
Configurator MPK Devices

For each dual−bus CP 330, enter the name of the output set that will be used to assign the two destinations.
For each CP 328 (including “/S” type) or CP 330/6, enter the name of the output set that will be used to assign the destinations.
For each CP 3809 Expansion Panel, the “Out Set” column must be blank.
For CP 3810 / 3810S / 3810L Expansion Panel entries, see page 5−131 and following.
For each CP 3832 or CP 3864 operated as a:
— Single−bus control panel, enter the name of the output that the panel is to control.
— “Split” panel, with some of the buttons used as inputs and some buttons used as outputs, enter the name of the
CP Output Set that will be used to assign destinations to the control panel’s output buttons.
— Main panel with a CP 3810 Expansion Panel, see page 5−131 and following for details.
Out Panel This column is used only for expansion panel configuration, when that panel will be used for addi- tional outputs.
For each CP 3832 or CP 3864 operated as an expansion output panel (in association with a source panel), select the MPK Device name of the associated main source panel in this column. See page 5−127.
For each CP 3809 Expansion Panel, select the name of the associated CP 3808 or CP 3830 main source panel.
For each CP 3810 Expansion Panel associated with a main source panel (CP 3832, CP 3864, CP 3808, or CP 3830), select the name of the main panel. See page 5−131 for an example.
For each CP 3830 Dedicated Output Panel, select the name of the associated CP 3830 main source panel (see page 5−126).
Level Set Select the CP Level Set name. Creation of CP Level Sets was described on page 5−58.
For each CP 3809 Expansion Panel, the Level Set column must be blank.
Override Set Select the CP Override set name. In addition to defining CP 3000 overrides, CP Override Sets are also used to assign input buttons on CP 300/310/330 and CP 3020 Push Button Control Panels. Crea- tion of CP Override sets was described on page 5−96.
Sequence set Select the CP Sequence set name. Creation of CP Sequence Sets was described on page 5−99.
Configurator MPK Devices

The output(s) that can be controlled by a control panel will depend on the CP Output Set entry for that panel on the MPK Devices menu:
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
Creation of Output Sets was described on page 5−78. The source of the output names is the Switcher Output table (page 5−55).
You may wish to review the “Out Set” discussion on page 5−110 for special entries required for some control panel ap- plications.
Configurator MPK Devices

In addition to individual Jupiter passwords assigned to each user, individual control panels can be given a password level. This can be used to provide varying levels of protection from one control panel to another.
To change the password level for a control panel:
In most cases, you will want to modify the set that is currently active; if so, you may want to copy the active set and select the copy for editing. For more information, please see Copying a Configuration Set for Editing on page 5−10.
In this example, the Password level column is blank, meaning that all control panels have a password level of zero. Therefore all passwords presently assigned will enable any panel.
Entering “50” would allow the panel to switch outputs having a security level of 50 or less.
Guidelines for using the editor are found on page 5−3.
Configurator MPK Devices

Use of control panels with the VGA Status Display requires entries to the MPK Devices table. The following example applies to the VGA system shown on page A−1.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−90. MPK device table entries for system shown on page A−1.
The VGA control panels can be configured to force unlock and force unprotect switcher outputs. This will normally require use of a password with a level of 90 or above. If you wish to enable force unlock/unprotect on a permanent basis, you should enter a password level of 90 or above for the VGA panels on the MPK Devices table.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Displaying Time Code on an MC 3000 Associated with a VGA Status Display
The entries shown above will allow the MC 3000 to control any machine pointed to by the VGA cursor. However, while the MC 3000 is under VGA cursor control no time code will be displayed in the MC 3000 display window. This function will require entries to the Machine Control table, as shown on page 5−148.
Configurator MPK Devices

Tally Interface Applications
When an MI 3040 is configured as an “MI 3040/T,” that is, configured to control tally lights (as shown on page 2−67 and following), an entry similar to that shown as row 1 in Figure 5−92 will be required. If there is more than one MI 3040, an entry with a unique Device Name will be required for each. This entry is the source of the Device Name for the MI 3040 and this same name must be selected on the Tally Dependency table (page 5−158).
If the tally system is being used in connection with a Saturn Master Control Switcher or a MCS 2000 Master Control Switcher, an additional entry will be required to allow the Jupiter system to gather tally information from the MCS. This entry will be similar to row 2 in Figure 5−92. The Device Name (“MCS_TLY” in this example) must also be selected on the Tally Depend- ency table (page 5−158). If more than one master control switcher is in the system, there must be an entry for each—for exam- ple, with Device Names such as “MCS_TLY1,” “MCS_TLY2,” etc. For Saturn, the “Board” is always the name of the video processor; the MPK “Port” is always “1” (this is true even if the MPK port is not physically connected to the MI−3040). For an MCS 2000, the “Board” is the name of the device that is the source of the TCS 2 bus, i.e., the device that is connected to the Machine Control port of the EC 2000 Control Electronics.
Devices word In Panel Out Panel Device
Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
MI−3040/T
SI1
MCS_TLY
MCS_TALY
DVP−1
Figure 5−92. Entry for MI 3040 used for tally.
Using the MI 3040 General Purpose / Tally Interface, an external device can transmit commands to, and receive status from, a Saturn Master Control Switcher. In this application, the MI 3040 is configured in software as an “MI 3040IO.” For more information, refer to “MI 3040IO” in the Saturn Installation and Operating manual.

Hardware installation was discussed on page 2−81. Software configuration varies according to the switching equipment used.
The system shown in Figure 5−93 corresponds to the MPK table shown in Figure 5−94.


Sequence Set Out Panel Override Set In Panel Output Sets
Figure 5−94. Entries for system shown in Figure 5−93.
Configurator MPK Devices · SlimLine Applications · Output names

Device Type “UMD3A” is used for all displays in the SlimLine series.
The address of SlimLine UMDs is set with front−panel buttons. For Dual Display (DD) models, the address of the first (left− hand) display is set manually; the address of the second display is automatically set to the same number plus 100 hex. For triple displays (i.e., using the Universal Display), the address of the first display is set manually; the address of the second display is automatically set to the same number plus 100 hex; and the address of the third display is automatically set to the same number plus 200 hex. For example, if the first display is set to “AA,” then the address of the second display is “1AA” and the address of the third display is “2AA.” For more information, refer to the SlimLine Under Monitor Displays Technical Manual.
The “Input Set” specified should be of type “UMD3A” and include all inputs and mnemonics that will be used on the status display. Each “Output Set” is not an actual Output Set, but is rather the name of the router output feeding the monitor next to the particular status display. The status display will follow the first level listed in the Level Set, e.g., if Video is the first level listed, then the mnemonic of the video input feeding the monitor will be shown.
Tally light operation. For SlimLine tally light operation, the MPK table must include an “MI 3040/T” entry (even if no actual MI 3040 hardware is in the system):
— If there is no MI 3040/T connected to the CM controlling the UMDs, you must define an imaginary MI 3040T
and assign it to the CM controlling the UMDs. Entries for “Port” and “Address” are not used but must be pres- ent to satisfy the compiler. See row 4 of Figure 5−94. The purpose of this entry is to launch a tally process within the CM.
— If an MI 3040/T does exist, and is connected to the CM controlling the UMDs, use the actual CM Board name,
Port, and Address.
Tally light operation will also require entries to the Tally Relay and Tally Dependency tables (see pages 5−152 and 5−158).
RP 1/2/3 and RP 1/2/3 C Applications
Configuration of the older model RP 1/2/3 displays is similar to the SlimLine units except that address(es) are set using rear− panel switches. There is no equivalent to the SlimLine Controller in RP 1/2/3 systems; the UMDs are instead connected in loop−through fashion directly to the CM 4000.
Configurator MPK Devices

Two methods are available for configuring UMDs with Saturn systems:
Configurator MPK Devices

If UMD status from a production switcher upstream of Saturn is needed, the “Jupiter control” method must be used. “Jupiter control” of UMDs is based on the software used for tally light control. See page 5−120 for an example system of this type.
Each UMD must named on the MPK Devices table (page 5−121).
The address of SlimLine displays is set using front−panel switches. For more information, see page 5−117.
Special Output Set tables of type “UMD3a” must be created to name all router outputs that can be selected for the Preset, Program, and Air busses.
The MI 3040 used to collect status information from the production switcher must be named on the MPK Devices table.
An “MCS_TLY” entry is required to allow the Jupiter system to gather status information from the Saturn. This entry will be similar to row 5 of the MPK Devices table on page 5−121.
If there is more than one master control switcher in the system, there must be an entry for each—for example, with the Device Names “MCS_TLY1,” “MCS_TLY2,” etc.
The Output sets, Tally Relay, and Tally Dependency tables are created as shown. Note that these entries allow for operation of a tally light connected to Relay 3 on the MI 3040 (if desired).
For information about activating UMD built−in tally lights, see “Tally Light Operation” on page 5−117.
Configurator MPK Devices


Figure 5−95. Example of UMD application with Saturn master control switcher and production switcher. Equipment shown here corresponds to tables on page 5−121.
Configurator MPK Devices


Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Saturn application MCS−2000 application

† Data in this field is not used, but an entry must be
selected to satisfy the Jupiter compiler.
x Data in this field is not used, but at least one charac-
ter must be entered to satisfy the compiler.

2 MISC 0 X MCS−B These rows must be in reverse order of the rows in the Preset Output Set

Figure 5−96. Tables for system shown on page 5−120.
TALLY1


Using the front−panel buttons, SlimLine and RP 1/2/3 series UMDs can be configured to display a mnemonic permanently. For more information, refer to the applicable UMD manual.
To cause the Jupiter system to display a mnemonic on a permanent basis, the MPK Devices table can be used to assign an Input Set to the status display containing only one input name and mnemonic. See Figure 5−97.
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set Devices word In Panel Out Panel Device
MPK Expansion Pass Board
CM1
Input Set — NET−INP
Figure 5−97.
Category Entry Mnemonic Logical
Net 1 NET NETIN
The Output Set entry is not used in this application; however, the name of an actual Output Set (or Output) must be entered to satisfy the compiler.
On the Input Set table, the Input field must be the name of an actual input.

Encore installation was discussed on page 2−91. Serial port configuration was discussed on page 5−30 and following.
Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set Devices word In Panel Out Panel
Figure 5−98. Entry for Encore control system.
The Input, Output, and Level Sets named on this table should include all inputs, outputs, and levels that will be controlled by the Encore.
The Input (page 5−62) and Output (page 5−78) sets must be created specifically for use by “serial” devices.
The Level Set must be created as a type “CP−3000” (see page 5−58.) For an important note about level numbering and external computer control, see page 5−60.
Hardware installation was discussed on page 2−60; serial port configuration was discussed on page 5−30. Figure 5−99 shows an example table for the system on page 2−60.

Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−99. Entry for system shown on page 2−60.
The dual entries are necessary because of the two hardware connections.
No “Address” entry is required.
The Input, Output, and Level Sets named on this table should include all inputs, outputs, and levels that will be controlled by the Diamond switcher. As a precaution, you may wish to restrict control to selected outputs.
For device Type “Diamond,” the Input and Output Sets must be created specifically for use by E−MEM devices. The Input Set is the source of the mnemonics that will appear on the Diamond console. The Output Set contains a cross−reference be- tween each router output wired to the DD switcher and a number that the DD will use to refer to that output.

Notice that device Type “Serial” is used for the “ASCII” protocol connection. For device Type “Serial,” the Input and Output Sets must be created specifically for use by “serial” devices: the Input Set describes which router inputs can be selected by the DD (and a number that the DD will use to refer to that input); the Output Set describes which router outputs are wired to the DD (and a number that the DD will use to refer to that output).
For details concerning CP Input Sets, see page 5−62.
For details concerning CP Output Sets, see page 5−78.
For details concerning CP Level Sets, see page 5−58.
Configurator MPK Devices

Automation control can be implemented with the JupiterXPress application or with the AccuSwitch application. Note that only one of these applications can be operated in a CM 4000 at one time.
Automation control of the JupiterXPress application can be via Jupiter ESswitch protocol (ESW) or the Jupiter ASCII Inter- face protocol. In either case device type “Serial” is selected on this table.

Board Input Sets Output Sets Level Set Overide Set Sequence Set In Panel Out Panel Type
Figure G−1.
The Address field should be left blank.
The Input, Output, and Level sets named on this table should include all inputs, outputs, and levels that will be controlled by the external control computer. As a precaution, you may wish to restrict computer control to selected outputs.
The Input and Output sets must be created specifically for use by “serial” devices. The Level Set must be created as a type “CP−3000.” For more information about these sets see page 5−58.
For a discussion of applicable MPK table entries, see Appendix G.
Configurator MPK Devices

Dedicated Output Panel
Dual CP 3830 panels can be configured so that the second panel is always used for output selection. The output panel’s buttons will glow amber.
CP 3830 “CP3830OU”
Dedicated output panel
Figure 5−100. CM 4000 “CM1”
Devices word In Panel Out Panel
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
KXYZ−INP
KXYZ−LEV KXYZ−OUT
CM1
2 CM1
CP3830OU CP−3830 2 00000043
CP3830IN
KXYZ−OUT KXYZ−LEV
CP3830IN
Figure 5−101. Entry for system shown in Figure 5−100.
Do the following to connect two CP 3830 panels together with one being an input panel and the other being an output panel:
The CP 3830 input panel can be independent of the output CP 3830. The output CP 3830 can still change the output for the input CP 3830 by selecting the new output name and doing a TAKE.

Except for unbalanced split§ and type “L”configurations, CP 3832 and CP 3864 panels can be combined to increase the num- ber of sources and destinations to a maximum of 128 x 128.
128 X 1 control station

Main CP 3864 “CP3864A”
CM 4000 “CM1”
Figure 5−102.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−103. Entry for system shown in Figure 5−102.
In this example, two CP 3864s are being operated as a 128 x 1 control station.
The top CP 3864 has been selected as the “main” panel; therefore it will be assigned to specific CP sets. Enter the name of the CP Input Set that will be used to assign inputs to all the buttons at this control station (for more information about CP Input Sets, see page 5−62). In the “Output Sets” column, enter the name of the output to be controlled. The main panel will always have the lowest−numbered input buttons.
Any panel used to expand the number of inputs (the bottom CP 3864 in this example) will use the “In Panel” column to select the MPK Device name of the main panel. It would use the CP sets assigned to the main panel. The first expansion panel listed in this table will have the button numbers immediately following those of the main panel; in this example panel “CP3864B” will have button numbers 65−128.
MPK Device table entries for other CP 3832/64 applications was discussed on page 5−109 and following.
§ For an overview of CP 3832 / 3864 configurations, see page 2−49.

48 X 16 control station
Hardware installation was discussed on page 2−49. Figure 5−105 shows an example MPK Devices table for the system in Figure 5−104.

“CP3832S”

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−105. Entry for system shown in Figure 5−104.
In this example, the top CP 3832 is being operated as a source expansion panel. In the MPK table, use the “In Panel” column to select the MPK Device name of the main panel (the bottom CP 3832 in this example). Any additional source panels would also refer to the “CP−3832S” in their In Panel column; they would use the CP sets assigned to the main panel.
The bottom CP 3832 is being operated in split mode, so the “Expansion” box is checked. The CP 3832 is considered to be the main panel because it is being used in split mode; therefore it will be assigned to specific CP sets. Enter the name of the CP Input and CP Output Sets that will be used to assign inputs and outputs to all the buttons at this control station. The main panel will always have the lowest−numbered input buttons.
If additional panels are added to provide more destinations, they would refer to the “CP−3832S” in their Out Panel column. They would use the CP sets assigned to the main panel. The first expansion panel listed in this table will have the button num- bers immediately following those of the main panel; the next expansion panel listed will have the next higher set of button numbers, etc.
The button numbers shown in Figure 5−104 correspond to the row numbers of the CP Input and Output Sets. See page 5−62 (CP Input Sets) and page 5−78 (CP Output Sets). MPK Device table entries for other CP 3832/64 applications was discussed on page 5−109 and following.
Configurator MPK Devices · 48 sources · Main CP−3832

64 X 32 control station

“CP3832”
Figure 5−106.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−107. Entry for system shown in Figure 5−106.
In this example, the CP 3864 is being operated as a source and “main” panel and the CP 3832 is being operated as a destination panel.
The top CP 3864 is considered to be the “main” panel because it controls the inputs; therefore it will be assigned to specific CP sets. Enter the name of the CP Input and CP Output Sets that will be used to assign inputs and outputs to all the buttons at this control station. See page 5−62 (CP Input Sets) and page 5−78 (CP Output Sets).
Any additional source panels would refer to the main panel (the CP 3864 in this example) in their In Panel column. They would use the CP sets assigned to the main panel. The first input expansion panel listed in this table will have the button num- bers immediately following those of the main panel; the next input expansion panel listed will have the next higher set of button numbers, etc.
For the CP 3832 in this example, use the Out Panel column to select the MPK Device name of the main panel. If additional panels are added to provide more destinations, they would also refer to the main panel (the CP 3864) in their Out Panel col- umn; they would use the CP sets assigned to the main panel. The first output panel listed in this table will have the lowest−num- bered set of buttons; the next output panel listed will have the next higher set of button numbers, etc.
MPK Device table entries for other CP 3832/64 applications was discussed on page 5−109 and following.
Configurator MPK Devices · Source (Main) Panel · Destination Panel

128 X 128 control station

CP 3864 “P3864X2”
CP 3864 “P3864Y1”
CP 3864 “P3864Y2”
Figure 5−108.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
In this example, the top two CP 3864s are being operated as source panels and the bottom two as destination panels.
The “main” panel is always an input panel. In this example, the top CP 3864 has been selected as the main panel and will therefore be assigned to specific CP sets. Enter the name of the CP Input and CP Output Sets that will be used to assign inputs and outputs to all the buttons at this control station. See page 5−62 (CP Input Sets) and page 5−78 (CP Output Sets).
Any additional source panels (CP 3864 “P3864X2” in this example) would refer to the main panel (the top CP 3864) in their In Panel column. They would use the CP sets assigned to the main panel. The first input expansion panel listed in this table will have the button numbers immediately following those of the main panel; the next input expansion panel listed will have the next higher set of button numbers, etc.
All destination panels use the Out Panel column to select the MPK Device name of the main panel; they would use the CP sets assigned to the main panel. The first output panel listed in this table will have the lowest−numbered set of buttons; the next output panel listed will have the next higher set of button numbers, etc. MPK Device table entries for other CP 3832/64 applications was discussed on page 5−109 and following.

The optional CP 3810 panel can be associated with a CP 3832, CP 3864, CP 3808, or CP 3830, providing control of up to 80 output buses. The CP 3810 can also be assigned to one output, providing breakaway (split) switching and/or multi−level status.
In the example shown in Figure 5−110, a CP 3832 is being used to select 32 inputs while the CP 3810 is used to select 80 outputs.
CP 3810 “CP3810”
80 destinations (8 windows X 10 pages)
Figure 5−110.
MPK
Devices word In Panel Out Panel
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
CM1
KXYZ−LEV
2 CM1
CP3810 CP−3810 2 00000044
CP3832
Figure 5−111. Entry for system shown in Figure 5−108.
Main panel entries — In this example, a CP 3832 is the “main” panel and is therefore assigned specific CP sets. In the “Input Set” column, enter the name of the CP Input Set that will be used to assign inputs to the main panel (for more information about CP Input Sets, see page 5−62). In the “Output Set” column, enter the name of the CP Output Set that will be used to assign outputs to the CP 3810 (for more information about CP Output Sets, see page 5−78).
CP 3810 entries — In the “In Panel” column, enter the name of the main panel. CP 3810S (“sticky outputs”) entries are similar to the CP 3810, except the Device Type is “CP−3810S.”
For operating instructions, see page 6−126.

In the example shown in Figure 5−112, a CP 3832 is used to select inputs and a CP 3810 is used to control the individual levels of one output. The CP 3810 can thus be used for breakaway switching.
The corresponding MPK table entries are shown in Figure 5−113.
CP 3810 “CP3810”
Figure 5−112.
Devices word In Panel Out Panel
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
CM1
KXYZ−LEV
2 CM1 KXYZ−LEV
CP3810 CP−3810L 2 00000044 CP3832
Figure 5−113. Entry for system shown in Figure 5−112.
Main panel entries — In this example, a CP 3832 is the “main” panel and is therefore assigned specific CP sets. In the “Input Set” column, enter the name of the CP Input Set that will be used to assign inputs to the main panel (for more information about CP Input Sets, see page 5−62). In the “Output Set” column, enter the name of the output that will be controlled.
For the CP 3810, select Device Type “CP−3810L.” Enter the name of the Main panel in the Input Set column.
For operating instructions, see page 6−126.
† Data not used, but entry must be present to satisfy compiler.

In the example shown in Figure 5−114, a CP 3864 is used to select inputs, a CP 3832 is used to select outputs, and a CP 3810 is used to control/status the individual levels of the output selected by the CP 3832. The CP 3810 can thus be used for break- away switching.

CP 3832 “CP3832”
CP 3810 “CP3810”
STATUS of individual levels
MPK bus Figure 5−114.

Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
Figure 5−115. Entry for system shown in Figure 5−108.
Main panel entries — In this example, a CP 3864 is used to select inputs and is therefore the “main” panel. As such, it is as- signed specific CP sets, as follows: In the “Input Set” column, enter the name of the CP Input Set that will be used to assign inputs to the main panel (for more information about CP Input Sets, see page 5−62). In the “Output Set” column, enter the name of the CP Output Set that will be used to assign Outputs to the destination panel CP 3832 (for more information about CP Output Sets, see page 5−78).
Destination panel entries — In the Out Panel column, select the name of the main panel.
CP 3810 entries — Select “CP 3810L” as the device type. In the In Panel column, select the name of the main panel.
For operating instructions, see page 6−126.
† Data not used, but entry must be present to satisfy compiler.

In this mode, the panel is configured to status a single output. No other panel is associated with the panel. and there is no switcher control. An example entry is shown in Figure 5−117.
CP 3810 “CP3810” Levels for 1
Figure 5−116.
MPK
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set Devices word In Panel Out Panel
CM1
Figure 5−117.
Select “CP−3810L” as the device Type. In the Output Set column, enter the name of the output to be statused.
For operating instructions, see page 6−126.

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines Machine Control 5−139 Delegation Groups 5−149
Name Type Board Port Address Machine Device
VT01 Sony Mch CM1 1
Status Display Header 5−150 VGA Status Display 5−151
VT05 Sony Mch CM1 7
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−118. Machines table for system shown on page 5−137.
This table is the source for information about machines using Sony serial protocol. Data entered here is automatically made available on the Machine Control table.§
Important: Row numbers on Jupiter tables are used as the “logical” numbers for devices. Changing the row num- ber of an existing device (by inserting/deleting a device in the middle of the table, for example) will disrupt con- trol of the machine, requiring linkages to be reestablished. One way to avoid this interruption is to add new de- vices at the end of tables.
Name This column lists the device names of all serial control machines in the system.
This is the source for machine names that appear on the control panels. Although this field will accept eight characters, you may wish to limit machine names to four since that is the maximum that can be displayed on the MC 3000’s expansion panel.
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27.

Type Device types (shown on a pull−down menu) are limited to the following:
Sony machine serial protocol
Ampex machine serial protocol†
Board Select the name of controller board connected to this machine. The source of these names is the Net- work Description table (page 5−27).
Port Number of controller board port connected to this machine. The port must support the necessary proto- col for this machine (as configured on the Serial Protocol table, page 5−30).
Address (hex) Unique serial data bus ID used to select and service this machine, entered in hexadecimal. (Not to be confused with LAN address entered on Network Description table shown on page 5−27.)
— not required for Sony “serial” VTRs (as listed on page 2−61).
† Not supported by Jupiter XPress application.
Configurator Machines Table


Figure 5−119. VTRs as listed in Machines table on page 5−135. (Machine control panels are listed in MPK table on page 5−107.)
Configurator Machines Table

This page intentionally left blank.
Configurator Machines Table

Configurator Machine Control Table
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control Delegation Groups 5−149
Device Name Device Type Delegation In/Out Associated
Status Display Header 5−150 VGA Status Display 5−151
VT01 Sony Mch In VT01
VC01 Sony Mch In VC01
VC02 Sony Mch In VC02
TAPEMC MC−3000E Out PRDA
Exclusion 5−188 Y Line 5−189
TAPEMC MC−3000E Out PRDB TAPEMC 5
TAPEMC MC−3000E Out PRDC TAPEMC 6
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
TMC3010 MC−3010 Out PRDX TMC3010 7
Figure 5−120.
This table is used to associate machines, machine controls, and router inputs/outputs in order to provide automatic machine assignment functionality (“control follows video”).§ It is also used when a PC is used as a Software Control Panel.†
Important: Row numbers on Jupiter tables are used as the “logical” numbers for devices. Changing the row num- ber of an existing device (by inserting/deleting a device in the middle of the table, for example) will disrupt con- trol of the machine, requiring linkages to be reestablished. One way to avoid this interruption is to add new de- vices at the end of tables.
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27. † Applies only when the Software Control Panel is used for machine control. For more information, see Section 7.

Configurator Machine Control Table
Device Name Device Type These columns repeat the descriptions of all machines (as entered on the Machines table, page 5−135) and machine control panels (as entered on the MPK Devices table, page 5−107).
Mnemonic Use of this column varies according to the device type.
For machines, this entry will appear on the panel controlling the machine:
For a serial control machine, the Mnemonic is always the same as the Device Name.
For control panels, the Mnemonic column is used only as a comment field.
Group This entry can be used to permanently assign a machine to a specific group of control panels. For more information, see page 5−149.
These entries are required for the machine assignment system to function, whereby machine control “follows” the routing switcher.
For machines, the entry in the In/Out column is always “In.” The Associated Name will be selected from a list of all router inputs (source = Switcher Input table, page 5−48). For a discussion of Associated Name entries, please see Assigning Machines to Control Panels starting on page 5−141.
For a CP 3000E, CP 3800, or CP 3810, the entry in the In/Out column is “Out.” The Associated Name col- umn is left blank.
For a complete description of MC 3000 and MC 3010 entries, please see Assigning Machines to Control Panels starting on page 5−141.
Preroll Number of seconds needed by this machine to come up to speed following a Play command. Most machines will lock up in one second or less; two seconds is often used as a preroll value to provide a safety margin. This value is used by the MC 3000 Machine Control Panel.
The MC 3000 uses this setting during Mark/Search operations. When SET MARK is pressed, the present time code is stored; when SEARCH MARK is pressed, the machine will move the tape to that point minus the preroll value. If there is no entry to the Machine Control Devices table, a two−second preroll will be used automatically.
For more information, see page 6−132 and Appendix E.
Saturn machine control configuration instructions are described in the Saturn Installation and Operating manual.
Delegation · Name In/Out · Associated

Configurator Machine Control Table
The Jupiter system has an automatic machine assignment function, whereby control of a VTR is linked to a remote panel based on the VTR being switched to a destination associated with that panel. In other words, machine control follows the routing switcher.
Summary of linkage system setup:
— The table must show the names of the routing switcher outputs which are wired to the destination (a pro-
duction switcher, in this example) that is associated with a particular machine control panel.
— The table must include the routing switcher input names associated with each VTR.
The linkage setup procedure is described in detail on the following pages.

Configurator Machine Control Table
Figure 5−121. Example of machine control linkage. Equipment shown here corresponds to table shown in Figure 5−122.


Configurator Machine Control Table

Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set


The Machine Control table shown in Figure 5−122 corresponds to the system shown in Figure 5−121. The applicable entries in the MPK Devices and Machines tables are shown for reference.
The “Associated Name” is the name of the routing switcher input or output to be associated with this particular device.
The first three rows show the names of the machines in the system and the associated routing switcher input names.
The next three rows (4, 5, and 6) relate to the SELECT buttons on the MC 3000 expansion panel; the order of entry on this table will be the same as the order of buttons on the panel. In this example, we want the first SELECT button to be assigned to whatever VTR is feeding routing switcher output “PRDA;” this is the output that feeds input A of the production switcher. Associated names are also entered for the following two SELECT buttons: “PRDB” and “PRDC.”
The next row (7) is similar to the entries just described, but pertains to the MC 3010 Dual 4 Machine Control panel. Again, the order of entry on this table will be the same as the order of button groups on the panel.
Given this table, Figure 5−121 shows what will happen when the indicated routing switcher crosspoints are closed. For exam- ple, the VTR “VT01” is shown switched to input A of the production switcher; that is, routing switcher input VT01 has been switched to output PRDA. The system will locate these two input/output names in the Machine Control table and find that control of VT01 must be assigned to the first SELECT button on the MC 3000 expansion panel. The device name and status for VT01 will be sent to the status displays indicating that control of the machine is now linked to this panel. (A detailed view of the MC 3000 expansion panel displays is shown in Figure 5−123.)

Configurator Machine Control Table
Figure 5−123 shows a detailed view of the CP 3000 and MC 3000 control panels previously shown in Figure 5−121 and listed in Figure 5−122.
The objective in this example is to use the CP 3000 switcher control panel to assign VTR “VT01” as the “A” input to the control room’s production switcher, and thereby link the machine to the MC 3000 Machine Control Panel.
For this discussion, it is assumed that switcher output PrdA has already been assigned to the first TAKE key of the CP 3000 expansion panel (the output assignment procedure is described on page 6−24).
[1] SELECT source. The operator presses “VTR,” then “1” on the CP 3000.
[2] TAKE to destination. Operator selects production switcher input “A” as the destination by pressing the first TAKE key on the expansion panel.
This will cause two things to happen:
— The VTR will be switched into the production switcher as “input A”, and the CP 3000 expansion panel will
show the display mnemonic for the VTR (“VT01”) in the status window.
— The system will check the Machine Control table (Figure 5−122) to see what control panel is associated with
the production switcher. At this point the link is established: the device name of the VTR, which is “VT01,” appears over the first SELECT button on the expansion panel next to the MC 3000 machine control panel, and the status of the machine appears as well.
[3] The START and STOP buttons (immediately below the device name) can now be used to operate VT01. Or:
[4] Press SELECT key to assign control of the VT01 to MC 3000 panel to the left.
The full status of VTR VT01, including time code, will appear in the MC 3000 display window.
[5] CONTROL all functions of VT01 using MC 3000.
If a different VTR is switched to production switcher input A, control of the new VTR will be brought to the MC 3000 machine control panel at the same time. In other words, no matter what VTR is selected as input “A,” a control command entered on the first button group of the expansion panel will be sent to the correct VTR.
It should be noted that this is the only way to gain control of a machine: it must be done by first selecting the machine with the switcher. This is true even if the machine does not actually pass through the switcher, as described on page 5−147.

Configurator Machine Control Table
A B C
A B C
Machine control linkage follows routing switcher
Identifies machines selected as sources for production switcher
00:54:49:11 T1 VT01 STOP MAN
STOP VT01
STOP VC01
STOP VC02
Expansion panel MC−3000 Machine control
SELECT machine to be controlled by MC−3000. Note asterisk next to machine name
START and STOP machine
CONTROL all functions of machine selected by expansion panel
Figure 5−123. Example of automatic machine linkage sequence. Please see page 5−144 for discussion.

Configurator Machine Control Table
Using the file server, machines can be linked directly to a specific control panel on a semi−permanent basis. An example sys- tem is shown in Figure 5−124. In this arrangement, only the file server can re−assign control of a machine to another panel. In other words, the normal linkage function (where machine control follows the routing switcher) is bypassed. The entries needed on the Machine Control table are shown in Figure 5−125.

software links established by file server Figure 5−124. Default machine control linkage.

Figure 5−125. Default linkage entries for system shown in Figure 5−124.

Configurator Machine Control Table
In some cases, machines may be wired directly to one destination, or to several destinations through distribution amplifiers only (see Figure 5−126). Although these machines do not pass through the routing switcher, it is still possible to use switcher control panels to establish linkages. In order to do this, imaginary switcher input and output names must be used as pointers on the Machine Control menu. These names, along with imaginary physical I/O numbers, must be entered on the Switcher Input and Output tables (pages 5−48 and 5−55). Also, the physical I/O numbers must be within the size range set on the Switcher Description menu (page 5−35).
Figure 5−126. Machine control linkage in system without routing switcher.


Configurator Machine Control Table
The CP 3010 expansion panel and the CP 3810 expansion panel can be used as a limited−function machine control panels, providing Start and Stop commands for VTRs.
When the CP 3010 is used as an expansion panel for a CP 3000 control panel, Start/Stop machine control is provided by the
and > buttons. When the CP 3810 is used as an expansion panel, Start/Stop machine control is provided by the PLAY/ STOP buttons. In both cases, machine control will require the following:
— The switcher level that is checked as the “MC” level on the Switcher Description table (page 5−35) must be the
same as the first level shown in the CP Level set (page 5−58) that is assigned to the CP 3000 (or to the main panel paired with the CP 3810) on the MPK Devices table (page 5−107). For example, the Video level would be checked as the “MC” level, “Video” would appear as the first level in the CP Level set, and this CP Level Set would be assigned to the main panel on the MPK Devices table;
and:
— The machine control buttons on the expansion panel must be assigned to the desired VTR by a process similar
to that described beginning on page 5−141.
Use of control panels with the VGA Status Display requires entries to the MPK Devices table, as described on page 5−114.
For an MC 3000 to display time code it would have to be linked to the machine exactly as any other MC 3000. This would require the following:
Device Name Device Type Delegation In/Out Associated Mnemonic
VMC VMC−3000 Out VGMon
Figure 5−127.
Saturn machine control configuration instructions are described in the Saturn Installation and Operating manual.
Machine Control · Group Name · Optional entry

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups
Status Display Header 5−150 VGA Status Display 5−151
2 ENG
3 TAPE
Exclusion 5−188 Y Line 5−189
Figure 5−128. Delegation groups menu (example).
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
The Delegation Groups menu, in conjunction with the Machine Control menu, can be used to restrict control of machines to a particular panel or group of panels. The Delegation Groups menu is used to establish group names.
To assign a machine to a particular control panel on a permanent basis, use the Machine Control menu to enter the group name of the panel in the “Delegation Group” column for the machine.
Device Name Device Type Delegation In/Out Associated
STUMC MC−3000 STU In STUMC 1
VT01 Sony Mch STU In VT01
VC01 Sony Mch STU In VC01
VC02 Sony Mch STU In VC02
Figure 5−129.
In this example (Figure 5−129), all three Sony machines have been permanently assigned to the “STU” MC 3000.

Thomson WXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 00 May 10, 1999 SWITCHER STATUS 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− OUTPUT VIDEO LEFT RIGHT TC −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PRDA VT01 PRDB VC01 VC01 VC01 PRDC VTR1 VTR1 VTR1 PRDD CAM1 ANN1 ANN1 VTR1 VTR2 SAT1 VTR3 CON2 CON2 CON2 VTR4 TST4 TST4 TST4 STUA BARS TONE TONE STUB CAM1 CAM1 CAM1 STUC STUA STUA STUA CON1 VTR5 CON2 CG02 CRT2 CRT2 CON3 CAM3 VC09 VC09 SAT1 CONA CONA CONA SAT2 NET NET NET SAT3 ENG2 ENG2 ENG2 SAT4 TSTB TSTB TSTB VGA Status Display
Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header VGA Status Display 5−151
Figure 5−130. Status display headers table (example).
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
This table is the source of the header that appears centered at the top of the VGA Status Display pages. Up to 60 characters can be entered. Only the entry on Row 1 is used.
For more information about the VGA Status Display, see Appendix A.

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display
VGA Status Display Table
VGA01
Exclusion 5−188 Y Line 5−189
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−131. VGA Status Display table (example).
This table is used when a VGA status display is installed.
Board is the name of the CM 4000 providing the VGA output. This must be the same as the name already entered on the Network Devices table.
Page File Name is the source of the name of the file that will be created when the “Tools > Generate VGA Files” command is run.
Video Mode allows selection of color or black and white. When “Color 80” is selected the table will display “VC8;” when “B/W 80” is selected the display will be “VB8.”
For details concerning VGA hardware installation and software configuration, please refer to Appendix A.

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
VT01
Exclusion 5−188 Y Line 5−189
TALLY1 2 VC01
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−132. Tally Relay description table.
An overview of Jupiter tally and a discussion of hardware installation can be found on page 2−67.
The Relay Description table must be used when an MI 3040 has been configured to operate as a “MI 3040/T,” i.e., for operation with tally lamps. The Tally Dependency table must also be used (page 5−158 ).
The table has a one−row entry for each of the tally lights in the system. The entry shows the name and relay number of the MI 3040 connected to each light; the source of this name is the MPK Devices table (page 5−115). Each relay is associated with the name of a routing switcher input, so that whenever that input is switched to air the relay will close. The source of the switcher input names is the Switcher Input table (page 5−48).
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27.

Figure 5−133 shows a tally system with a Jupiter−controlled routing switcher, a Saturn (or non−Saturn) master control switcher, and a direct feed to the transmitter. The corresponding Tally Relay Descriptions table is also shown. Notice that the table remains the same whether or not a Saturn master control switcher is used.
Figure 5−134 shows a system with a Jupiter−controlled routing switcher, Saturn (or non−Saturn) master control, and a produc- tion switcher. The master control switcher is connected directly to the transmitter. The corresponding Tally Relay Descrip- tions table is also shown. Notice that the table remains the same whether or not a Saturn master control switcher is used.
Figure 5−135 shows a system in which the master control switcher is connected to the transmitter indirectly, i.e., by re−entry through the routing switcher. Again, the figure includes the corresponding Tally Relay Descriptions table. In this case, a tally light for the master control switcher must be identified in the table (but not necessarily installed, as described previously).
The table is also used for systems with SlimLine (and RP 1/2/3) Status Displays, when an MI 3040 is being used to trace inputs back through a production switcher. See page 5−121.
Figure 5−136 shows a system with SlimLine Status Displays when the front panel tally lights are used. The Tally Relay De- scription table must include a one−row entry for each tally light pair. The source for the “Name” is the MPK Devices table (page 5−94); the “Relay” entry is always “1” and the “Switcher Input” number is an existing switcher input name as defined on the Switcher Input table (page 5−48). The “Switcher Input” entry is not actually used, but to satisfy the compiler a name must be entered which is unique within this table.
In all cases, the Tally Dependency table must also be completed, as described on page 5−158.
Configurator Tally


Ï Ï ÏÏ Ï
1 TALLY1 0 VT01 2 TALLY1 1 VC02 3 TALLY1 2 VC01
Figure 5−133. Tally system with Jupiter−controlled router, Saturn (on non−Saturn) master control, and di- rect feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally


Ï ÏÏ ÏÏÏ ÏÏ
1 TALLY1 0 VT01 2 TALLY1 1 VC02 3 TALLY1 2 VC01 4 TALLY1 3 PRD
Figure 5−134. Tally system with Jupiter−controlled router, Saturn (or non−Saturn) master control, production switcher, and direct feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally


Ï ÏÏ ÏÏ ÏÏÏ
Tally Device Relay Logical Input
1 TALLY1 0 VT01 2 TALLY1 1 VC02 3 TALLY1 2 VC01 4 TALLY1 3 PRD 5 TALLY1 4 MCS
Figure 5−135. Tally system with Jupiter−controlled router, Saturn (or non−Saturn) master control, production switcher, and indirect feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally · Tally Relay


1 TALLY1 0 VT01 2 TALLY1 1 VC02 3 TALLY1 2 VC01 4 TALLY1 3 PRD 5 TALLY1 4 MCS 6 UMDSD1 1 111 7 UMDDD1A 1 222 8 UMDDD1B 1 333
Figure 5−136. SlimLine tally system with Jupiter−controlled router, Saturn (or non−Saturn) master control, production switcher, and indirect feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−137. Tally Dependency table (example).
MAIN−A
Exclusion 5−188 Y Line 5−189
MCS_TLY 2 KEYINS1
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
MCS_TLY 4 MIXINS1
6 MCS_TLY 5 MIXINS2
7 MCS_TLY 6 BYPASS
OVERVIEW
This table must be used when an MI 3040 has been configured to operate as a “MI 3040/T,” i.e., for operation with tally lamps. The Tally Relay table must also be used (page 5−152).
The table has two basic purposes: first, to establish the identity of the main output of the system (the output being fed by the tallied source); and second, to allow the Jupiter system to track sources through switchers other than the routing switcher.
Whatever source is feeding the main output (usually a transmitter) is tallied. When the main output is fed directly from the routing switcher, it is referred to as an unqualified output; a sample entry is shown in Figure 5−138.
Tally Device Opto Logical Output
Figure 5−138. Entry used when main output is fed by router.

If the main output is fed from a switcher other than the router (such as a master control switcher), then the main output is not identified as such. Instead, the names of all possible routing switcher outputs that could be selected for the main output are listed (“Output” column in Figure 5−139). In this case, the master control switcher must tell the Jupiter system which routing switcher output has been selected; this is done by energizing the appropriate opto−isolator (“Name/Opto” columns).
MAIN−A
2 MCS_TLY 1 MAIN−B
3 MCS_TLY 2 KEYINS1
4 MCS_TLY 3 KEYINS2
5 MCS_TLY 4 MIXINS1
6 MCS_TLY 5 MIXINS2
Figure 5−139. Entry used when main output is fed by switcher other than router.
There may be additional switching layers other than the router (such as a production switcher). In this case, the system must be able to determine (a) whether the switcher is on the air, and if it is, (b) which routing switcher output has been selected. An entry to the “Tally” column (Figure 5−140) will identify the tally light associated with the switcher; if the light is on, then the switcher is on the air. If it is on the air, the opto−isolators will be checked to find out which router output has been selected.
PROD1
TALLY1 /3
2 TALLY1 1 PROD2 TALLY1 /3
Figure 5−140. Additional switcher entries.
The source of the Tally column data (name of MI 3040 / relay number connected to each tally light) is the Tally Relay table (page 5−152).
Entries for specific systems are shown below; this is followed by a detailed example of system operation.

Direct Connection to Transmitter
Please see Figure 5−142.
This table has only one type of entry: MCS_TLY.
These entries are used in systems equipped with a Saturn Master Control Switcher (or BTS MCS 2000). They allow the Jupiter system to find out which of the sources feeding the master control switcher have been switched to the MCS “On−air” output. There are always five entries for the MCS 2000, one for each of the five inputs from the routing switcher. For the Saturn, there are seven entries.
The source of the Name used here is the MPK Devices table (for discussion, see page 5−115). As a convention, the name “MCS_TLY” is used.
The Opto−isolator number entries must be assigned as follows:
Figure 5−141. Additional switcher entries.
MCS_TLY Opto−isolator no.
Assigned to MCS 2000 input
Assigned to Saturn input
0 Input 1 BKGDA
1 Input 2 BKGDB
2 Key 1 KEY 1
3 Key 2 KEY 2
5 −−− MIX 2
The Switcher Outputs are the names of the five router outputs leading to the master control switcher. The source of the switcher output names is the Switcher Output table (page 5−55).
The MCS_TLY entries do not include a dependency on a relay, since no tally light is associated with the master control switcher. (There is no tally light because in this system the master control switcher is always on−air.) The last two col- umns are therefore left blank.
Configurator Tally · Saturn (“MCS_TLY”) entries · 6 Bypass BYPASS

Saturn audio processor Saturn video processor
BUS INPUTS
KEY 1 KEY 2 BKGDA BKGDB BYPASS
ISO1 ISO2
MIX 1 MIX 2 MAIN A MAIN B BYPASS
L R L R L R L R L R
MAIN−B 001
KEYINS1 002
KEYINS2 003
BYPASS 004
ISO 1 005
ISO 2 006
MAIN−A 000
MAIN−B 001
MIXINS1 002
MIXINS2 003
BYPASS 004
Tally Device Opto Logical Output Tally
1 MCS_TLY 0 MAIN−A 2 MCS_TLY 1 MAIN−B 3 MCS_TLY 2 KEYINS1 4 MCS_TLY 3 KEYINS2 5 MCS_TLY 4 MIXINS1 6 MCS_TLY 5 MIXINS2 7 MCS_TLY 6 BYPASS
Figure 5−142. Example tally system with Jupiter−controlled router (Venus), Saturn master control, and direct feed to transmitter. Equipment shown corresponds to table at left.

Please see Figure 5−143.
There are two types of entries on this table: an unqualified output entry and MCS_TLY entries.
This is the name (“XMIT”) of the routing switcher output leading to the transmitter (or the name of the output leading to the primary program line). All sources switched to this output will be tallied. The rest of the row remains blank. There can be more than one unqualified output if desired.
Entries are similar to those already described (page 5−164) except for the last two columns. Since the master control switcher is connected indirectly to the transmitter (by re−entry through the routing switcher), each entry must include the Name of the MI 3040/T and the relay Number associated with the master control switcher’s tally light.
Configurator Tally · Unqualified output · Saturn (“MCS_TLY”) entries


ÏÏ ÏÏ Ï
KEY 1 KEY 2 BKGDA BKGDB BYPASS BUS INPUTS
MIX 1 MIX 2 MAIN A MAIN B BYPASS BUS INPUTS
L R L R L R L R L R
1 XMIT 2 MCS_TLY 0 MAIN−A TALLY1 /4 3 MCS_TLY 1 MAIN−B TALLY1 /4 4 MCS_TLY 2 KEYINS1 TALLY1 /4 5 MCS_TLY 3 KEYINS2 TALLY1 /4 6 MCS_TLY 4 MIXINS1 TALLY1 /4 7 MCS_TLY 5 MIXINS2 TALLY1 /4 8 MCS_TLY 6 BYPASS TALLY1 /4
Figure 5−143. Example tally system with Jupiter−controlled router (Venus), Saturn master control, and indirect feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally

Direct Connection to Transmitter
Please see Figure 5−145.
There are two types of entries on this table: MCS_TLY entries; and production switcher entries. There is no unqualified output entry.
These entries are used in systems equipped with a Saturn Master Control Switcher (BTS MCS 2000). They allow the Jupiter system to find out which of the sources feeding the master control switcher have been switched to the “On−air” output. There are always five entries for the MCS 2000, one for each of the five inputs from the routing switcher. For the Saturn, there are seven entries.
The source of the Name used here is the MPK Devices table (for discussion, see page 5−115). As a convention, the name “MCS_TLY” is used.
The Opto−isolator number entries must be assigned as follows:
Figure 5−144.
MCS_TLY Opto−isolator no.
Assigned to MCS 2000 input
Assigned to Saturn input
0 Input 1 BKGDA
1 Input 2 BKGDB
2 Key 1 KEY 1
3 Key 2 KEY 2
5 −−− MIX 2
The Switcher Outputs are the names of the five router outputs leading the master control switcher. The source of the switcher output names is the Switcher Output table (page 5−55).
The MCS_TLY entries do not include a dependency on a relay, since no tally light is associated with the MCS. (There is no tally light because in this system the MCS is always on−air.) The last two columns are therefore left blank.
Configurator Tally · Saturn (“MCS_TLY”) entries · 6 Bypass BYPASS


KEY 1 KEY 2 BKGDA BKGDB BYPASS BUS INPUTS
MIX 1 MIX 2 MAIN A MAIN B BYPASS
L R L R L R L R L R
1 MCS_TLY 0 MAIN−A 2 MCS_TLY 1 MAIN−B 3 MCS_TLY 2 KEYINS1 4 MCS_TLY 3 KEYINS2 5 MCS_TLY 4 MIXINS1 6 MCS_TLY 5 MIXINS2 7 MCS_TLY 6 BYPASS 8 TALLY1 0 PROD1 TALLY1 /3 9 TALLY1 1 PROD2 TALLY1 /3
Figure 5−145. Example tally system with Jupiter−controlled router (Venus), Saturn master control, production switcher, and direct feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally · Transmitter

These entries will allow the Jupiter system to find out which of the sources feeding the production switcher have been switched to the switcher’s Program output. The number of entries will be the same as the number of inputs from the routing switcher.
The Name is that of the MI 3040/T connected to the production switcher’s tally outputs. The source of this name is the MPK Devices table (page 5−115). As a convention, a name such as “TALLY1” is used.
The Opto−isolator number entries are based on the corresponding router output names. In this example, when the pro- duction switcher has switched “PROD1” to its program output, it will report this by energizing opto−isolator number 0 on “TALLY1.”
The Switcher Outputs are the names of the router outputs leading the production switcher. The source of these output names is the Switcher Output table (page 5−55).
In the Tally column, select the name of the MI 3040/T / relay number associated with the production switcher’s tally light. The source of the Tally column data is the Tally Relay table (page 5−152).
Configurator Tally · Production Switcher Entries

This page intentionally left blank.
Configurator Tally

Please see Figure 5−146.
There are three types of entries on this table: an unqualified output entry; MCS_TLY entries; and production switcher entries.
This is the name (“XMIT”) of the routing switcher output leading to the transmitter (or the name of the output leading to the primary program line). All sources switched to this output will be tallied. The rest of the row remains blank. There can be more than one unqualified output if desired.
Similar to those already described (page 5−164), except for the last column. Since the master control switcher is con- nected indirectly to the transmitter (by re−entry through the routing switcher), each entry must include the name of the MI 3040/T and the relay number associated with the master control switcher’s tally light.
Similar to those already described (page 5−166).


Ï ÏÏ Ï Ï
KEY 1 KEY 2 BKGDA BKGDB BYPASS BUS INPUTS
MIX 1 MIX 2 MAIN A MAIN B BYPASS
L R L R L R L R L R
1 XMIT 2 MCS_TLY 0 MAIN−A TALLY1 /4 3 MCS_TLY 1 MAIN−B TALLY1 /4 4 MCS_TLY 2 KEYINS1 TALLY1 /4 5 MCS_TLY 3 KEYINS2 TALLY1 /4 6 MCS_TLY 4 MIXINS1 TALLY1 /4 7 MCS_TLY 5 MIXINS2 TALLY1 /4 8 MCS_TLY 6 BYPASS TALLY1 /4 9 TALLY1 0 PROD1 TALLY1 /3 10 TALLY1 1 PROD2 TALLY1 /3
Figure 5−146. Example tally system with Jupiter−controlled router (Venus), Saturn master control, production switcher, and indirect feed to transmitter. Equipment shown corresponds to table at left.
Configurator Tally

Tally Device Opto Logical Output
2 TALLY1 2 MCS1 TALLY1 /4
3 TALLY1 3 MCS2 TALLY1 /4
4 TALLY1 4 MCS3 TALLY1 /4
5 TALLY1 5 MCS4 TALLY1 /4
6 TALLY1 6 MCS5 TALLY1 /4
7 TALLY1 0 PROD1 TALLY1 /3
Figure 5−147. Tally dependencies table for systems with non−Saturn master control switcher (Figure 5−148).
The Tally Dependency table shown above (Figure 5−147) corresponds to the system shown in Figure 5−148.
This table is similar to that already described, except that it shows the required connections from the non−Saturn master con- trol switcher to the MI 3040/T opto−isolators.
Configurator Tally · Tally Dependency · Tally

MCS2
MCS3
MCS4
MCS5
XMIT
PROD1
PROD2
2 0 1 3 4
2 0 1 3 4
Figure 5−148. Example of tally system with non−Saturn master control switcher. Equipment shown here corre- sponds to table shown in Figure 5−147.


Figure 5−149. Example of tally system operation. Equipment shown here corresponds to tables and discussion on next page.
Configurator Tally

Figure 5−150. Tables for system shown in Figure 5−149.
Tally Device Opto Logical Output Tally
Tally Device Relay Logical Input
1 XMIT 2 MCS_TLY 0 MCSM1 TALLY1 /4 3 MCS_TLY 1 MCSM2 TALLY1 /4 4 MCS_TLY 2 MCSK1 TALLY1 /4 5 MCS_TLY 3 MCSK2 TALLY1 /4 6 MCS_TLY 6 MCSBP TALLY1 /4 7 TALLY1 0 PROD1 TALLY1 /3 8 TALLY1 1 PROD2 TALLY1 /3
1 TALLY1 0 VT01 2 TALLY1 1 VC02 3 TALLY1 2 VC01 4 TALLY1 3 PRD 5 TALLY1 4 MCS
The following discussion refers to Figures 5−149 and 5−150 above. All references to “inputs” and “outputs” are from the routing switcher point of view. Only video is shown in this example.
The system finds unqualified output “XMIT” on Tally Dependency table. All sources switched to this output will be tallied. The system checks the routing switcher status tables and finds that input “MCS” (the master control switcher) is switched to output “XMIT.”
The system locates “MCS” on Tally Relay Descriptions table, according to which relay no. 4 of MI 3040 “TALLY1” should be turned on. This turns on the tally light next to the MCS.
Tally 1, relay 4 is located on the Tally Dependency table. There are five entries, one for each possible source for the MCS. Each depends (is conditional) on relay 4 to be closed in order to point back to a tally light.
The system checks the MCS (“MCS_TLY”) to determine which source has been selected; in this case it is output “MCSM1.” The system looks at the routing switcher status table and finds that input “PRD” (the pro- duction switcher) is switched to output “MCSM1.”
The system locates “PRD” on the Tally Relay Descriptions table, according to which relay 3 of Tally 1 should be turned on. This relay turns on the tally light next to the production switcher.
Tally 1, relay 3 is located on the Tally Dependency table. There are two entries, one for each possible router output to the production switcher.
The system now checks opto−isolators 0 and 1 of Tally 1 to determine which source has been selected by the production switcher. Opto−isolator 0 is energized, meaning that output “PROD1” is selected. (In other words, relay 3 is ANDed with opto 0.) The system looks at the routing switcher status table and finds that input “VT01” is switched to output “PROD1.”
The system locates “VT01” on the Tally Relay Descriptions table, according to which relay 0 should be turned on. This turns on the tally light next to the VTR.
Configurator Tally · Tally Dependency · Tally Relay

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Figure 5−151. Path finding data table (example).
Status Display Header 5−150 VGA Status Display 5−151
Path Finding Group Name
Exclusion 5−188 Y Line 5−189
VIDEO (NEWSROUT)
VIDEO (MAINROUT)
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
LNEWMAIN
LEFT (MAINROUT)
3 RIGHT (NEWSROUT 10 43 5
RNEWMAIN
RIGHT (MAINROUT)
4 TC (NEWSROUT) 10 43 5
TNEWMAIN
TC (MAINROUT)
5 VIDEO (MAINROUT) 61 20 3
VMAINNEW
VIDEO (NEWSROUT)
6 LEFT (MAINROUT) 61 20 3
LMAINNEW
LEFT (NEWSROUT)
7 RIGHT (MAINROUT) 61 20 3
RMAINNEW
RIGHT (NEWSROUT
8 TC (MAINROUT) 61 20 3
TMAINNEW
TC (NEWSROUT)
The path finding§ software option allows two or more Venus, Trinix, or later routing switchers to operate as a system, where one switcher can access the other’s inputs through a number of tie lines. For example, Figure 5−152 shows a facility with a large, central distribution switcher and a smaller switcher normally used only within the news department. By placing both switchers under control of the Jupiter system, and by adding tie lines, the main router can access the news department’s inputs. In this example, VT21 can be switched to output 55 of switcher “MAINROUT” with one command: the system will first switch VT21 to one of the tie lines leading from “NEWSROUT” to “MAINROUT,” then it will switch that tie line signal to output 55 of “MAINROUT.”
Path finding is not the same as three−stage switching. Path finding involves discrete switchers connected by a small number of tie lines, the number of which strictly limits the inputs available at the downstream switcher.
§ Some of the functions described in this section may be extra−cost options. For more information, see page 1−27.

If all tie lines are busy and an attempt is made to switch to an additional upstream source, the control panel will indicate “Blocked.” In order to release a tie line, a downstream output using a tie line must be switched to a local input. In this example, “MainRout” output 55 could be switched to VT16, or some other source known to be a local input (such as black burst). In some cases, it might be necessary to switch more than one downstream output to a local source, since the tie line could be feeding more than one destination. Since it may be difficult to determine the overall usage of a given tie line, the operator should switch away from the upstream switcher source when it is no longer needed.†
Following hardware installation (discussed on page 2−33), path finding requires entries to the Path Finding Data table and selection of Group Names numbers on the Switcher Input tables (Figure 5−151).
This table, shown in Figure 5−151, describes the tie lines between the two switchers. The first four rows show the lines from “NEWSROUT” to “MAINROUT,” and the next four rows show the lines leading back to “NEWSROUT.” In this case, there are tie lines for all four levels of both switchers. The columns are arranged in “from—to” order.
Row 1 describes lines from Input Switcher “NEWSROUT,” Video level, starting with Physical Output 10. The lines go to Output Switcher “MAINROUT,” Video level, starting with Physical Input 43. Since there are five lines, and connections must be consecutive, outputs 10 through 14 of “NEWSROUT” are connected to inputs 43 through 47 of “MAINROUT.”
† With Jupiter version 4.0, the VGA Status Display can be made to display tie line status. See Appendix A.
Configurator Path Finding

Referring to Figure 5−153 and the Switcher Input table for “NEWSROUT,” the entries for VT21 and VT22 follow the normal pattern. However, there are also entries for VT15 and VT16—machines that are normally sources for “MAINROUT.” In the following columns, there are Group Name selections such as “VNEWMAIN,” “LNEWMAIN,” etc. If there is a request for VT15 to be switched to a “NEWSROUT” output, then the system is referred to Groups VMAINNEW through TMAINNEW on the Path Finding Data table. The VMAINNEW entry, for example, shows that for video there are three tie lines available to make this switch. Assuming that one of these lines is available, the switch will be completed.

Figure 5−152. Example of sequential path finding connec- tions between video levels of two switchers. For correspond- ing tables, see Figure 5−153.
17 18 19 20 21 22 23 24 25
In this example, this group of tie lines is named “VNEWMAIN” (vid- eo, NEWSROUT to MAINROUT). Other naming schemes could use “GROUP1,” or, more elaborate names like “V5N10M43,” meaning “Video, 5 News lines starting at output 10 to Main router starting at input 43,” etc.)
38 39 40 41 42 43 44 45 46 47 48 55
In this example, this group of tie lines is named “VMAINNEW.”
Configurator Path Finding

Path Finding Physical Physical Group Name Source Switcher/Level Output Destination Switcher/Level Input Count
Tie lines from “NEWSROUT” to “MAINROUT”
1 VNEWMAIN VIDEO (NEWSROUT) 10 VIDEO (MAINROUT) 43 5 2 LNEWMAIN LEFT (NEWSROUT) 10 LEFT (MAINROUT) 43 5 3 RNEWMAIN RIGHT (NEWSROUT) 10 RIGHT (MAINROUT) 43 5 4 TNEWMAIN TC (NEWSROUT) 10 TC (MAINROUT) 43 5 5 VMAINNEW VIDEO (MAINROUT) 61 NEWSROUTVIDEO 20 3 6 LMAINNEW LEFT (MAINROUT) 61 NEWSROUTLEFT 20 3 7 RMAINNEW RIGHT (MAINROUT) 61 NEWSROUTRIGHT 20 3 8 TMAINNEW TC (MAINROUT) 61 NEWSROUTTC 20 3
Tie lines from “MAINROUT” to “NEWSROUT”
Switcher Input − NEWSROUT
Name VIDEO LEFT RIGHT TC
30 VT21 023 31 VT22 024
45 VT15 VMAINNEW LMAINNEW RMAINNEW TMAINNEW 46 VT16 VMAINNEW LMAINNEW RMAINNEW TMAINNEW
Switcher Input − MAINROUT
Name VIDEO LEFT RIGHT TC
23 VT15 038 24 VT16 039
45 VT21 VNEWMAIN LNEWMAIN RNEWMAIN TNEWMAIN 46 VT22 VNEWMAIN LNEWMAIN RNEWMAIN TNEWMAIN
Figure 5−153. Sequential Path finding and Switcher inputs tables for system shown in Figure 5−152.

Connecting three switchers for path finding purposes possible, with five as the recommended maximum. This is illustrated in Figure 5−154. Notice that no tie lines directly connect switcher “A” and switcher “C.”
In the corresponding Path Finding Data table, there would be descriptions of the tie lines from “A” to “B,” from “B” to “A,” from “B” to “C,” and from “C” to “B.”
Note: There may be situations where wiring would allow manual selection of alternate routes. In Figure 5−154, this would be the case if video lines also existed between switcher “A” and switcher “C. ” However, the Jupiter path finding software cannot take advantage of such alternate routes; in other words, it does not “switch around busy areas.” Only one possible route between each pair of switchers can be described on the Path Finding Data table when the system is configured.
There would also be Group entries in the Switcher Input tables of all three switchers:
— For the switcher “A” table, the names of sources available through path finding would all be referenced to the
tie lines from switcher “B” to “A.” This would include the sources wired directly to switcher “C.”
— For the switcher “B” table, the names of sources available through path finding would be referenced to the tie
lines from switcher “A” to “B,” or, from “C” to “B,” as appropriate.
— For the switcher “C” table, the names of sources available through path finding would all be referenced to the
tie lines from switcher “B” to “C.” This would include the sources wired directly to switcher “A.”
In general, path finding entries are needed only for switchers that are immediately adjacent. The system will use this informa- tion to find paths involving one or more intermediate switchers.
Configurator Path Finding


Figure 5−154. Example of path finding connections between video levels of three switchers.
Configurator Path Finding

This page intentionally left blank.
Configurator Path Finding

Automatic Conversion of Separate Analog Signals to Combined Digital Signals
The pathfinding table can be used with customer−supplied ADCs and DACs to provide automatic conversion between analog equipment and digital equipment (such as VTRs). See Figure 5−155.

For example, this technique can be used for conversion of analog audio signals, which are carried on two levels of an analog routing switcher, to a single digital audio (AES) signal. The same concept can be applied in an embedded audio environment, where a single digital video stream can be split into an analog video signal and up to four analog audio signals.
It is possible to arrange a system so that the conversion will take place whenever the operator selects a particular source and switches it to a particular destination. For example, in the system shown in Figure 5−156, whenever the operator selects VTR1 as the source for VTR2, the analog audio signals will always pass through an A to D converter; when VTR2 is the source for VTR1, the digital signal will pass through a D to A converter.
Configurator Path Finding

Figure 5−156. Example of automatic conver- sion system (video connections not shown). For corresponding table entries, see Figure 5−157.
LEFT”
TIE LINE GROUP 1
TIE LINE GROUP 2
6 7 “MAINROUT
A TO D CONVERTER
RIGHT”
26 27 “MAINROUT
AES”
“VTR2” (DIGITAL)
TIE LINE GROUP 3
D TO A CONVERTER
TIE LINE GROUP 4
This system will require four tie lines, with a dedicated A to D converter connected to the first pair and a dedicated D to A converter connected to the second pair. Each pair is “locked” together, meaning that selection of one result in selection of both.
The corresponding table entries are shown in Figure 5−157.
There are three rules governing this technique:
Configurator Path Finding

DM 400 Switcher Level VI RV MC Board #In #Out PLvl Follow Level Driver 3 LI 3 LO Option Audio Off Time
1 MAINROUT LEFT CM1 64 64 2 Binary Left 2 MAINROUT RIGHT CM1 64 64 6 Binary Right 3 MAINROUT AES CM1 64 64 32 Binary None
Path Finding Physical Physical Group Name Source Switcher/Level Output Destination Switcher/Level Input Count
“Locked” tie lines through A to D converter
1 GROUP1 LEFT (MAINROUT) 16 AES (MAINROUT) 18 1 2 GROUP2 RIGHT (MAINROUT) 6 AES (MAINROUT) 18 1 3 GROUP3 AES (MAINROUT) 27 LEFT (MAINROUT) 0 1 4 GROUP4 AES (MAINROUT) 27 RIGHT (MAINROUT) 4 1
“Locked” tie lines through D to A converter
Switcher Input − MAINROUT
Name LEFT RIGHT AES
30 VTR1 001 005 GROUP1 31 VTR2 GROUP4 GROUP3 019
Figure 5−157. Table entries for system shown in Figure 5−156 (video entries not shown).
Switcher Output − MAINROUT
Logical Output Pass Name Security S−T Word LEFT RIGHT AES

This page intentionally left blank.
Configurator Path Finding

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−158. Non−Sequential Path Finding data table (example).
Exclusion 5−188 Y Line 5−189
Number Output Input Group Name
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
3 GROUP2 3 83 87
4 GROUP2 4 84 88
5 GROUP3 3 83 87
6 GROUP3 4 84 88
7 GROUP4 3 83 87
8 GROUP4 4 84 88
9 GROUP5 2 82 20
10 GROUP6 2 82 20
11 GROUP7 2 82 20
12 GROUP8 2 82 20
The path finding software option has already been described in detail, starting on page 5−174.
The Non−Sequential Path Finding table must be used if the tie lines joining the switchers are not wired sequentially, i.e., not wired as blocks. Basically, the table is designed to enter “exceptions” to the Sequential table. For example, a new tie line that falls outside the original sequence can be defined on the Non−sequential table; the only change then needed on the Sequential table would be to increment the “Count” number for the group by 1. (Alternatively, you may prefer to use the Non−sequential table to define all tie lines individually.)
An example system is shown on page 5−186, with corresponding tables shown on page 5−187. Notice that the Path Finding Data table, and the Switcher Input tables, must still be used as described in the previous section.


Figure 5−159. Example of non−sequen- tial path finding connections between video levels of two switchers. For corre- sponding tables, see Figure 5−160.
Configurator Path Finding

Path Finding Physical Physical Group Name Source Switcher/Level Output Destination Switcher/Level Input Count
Tie lines from “NewsRout” to
1 GROUP1 VIDEO (NEWSROUT) 13 VIDEO (MAINROUT) 44 5 2 GROUP2 LEFT (NEWSROUT) 13 LEFT (MAINROUT) 44 5 3 GROUP3 RIGHT (NEWSROUT) 13 VIDEO (MAINROUT) 44 5 4 GROUP4 TC (NEWSROUT) 13 TC (MAINROUT) 44 5 5 GROUP5 VIDEO (MAINROUT) 61 VIDEO (NEWSROUT) 26 3 6 GROUP6 LEFT (MAINROUT) 61 LEFT (NEWSROUT) 26 3 7 GROUP7 RIGHT (MAINROUT) 61 RIGHT (NEWSROUT) 26 3 6 GROUP8 TC (MAINROUT) 61 TC (NEWSROUT) 26 3
Tie lines from “MainRout” to “NEWSROUT”
Path Finding Line Physical Physical Group Name Number Output Input
1 GROUP1 3 83 87 2 GROUP1 4 84 88 3 GROUP2 3 83 87 4 GROUP2 4 84 88 5 GROUP3 3 83 87 6 GROUP3 4 84 88 7 GROUP4 3 83 87 8 GROUP4 4 84 88 9 GROUP5 2 82 20 10 GROUP6 2 82 20 11 GROUP7 2 82 20 11 GROUP8 2 82 20
Switcher Input − NewsRout
Switcher Input − MainRout
Name VIDEO LEFT RIGHT TC
Name VIDEO LEFT RIGHT TC
30 VT21 033 31 VT22 034
23 VT15 001 24 VT16 002
45 VT15 GROUP5 GROUP6 GROUP7 GROUP8 46 VT16 GROUP5 GROUP6 GROUP7 GROUP8
45 VT21 GROUP1 GROUP2 GROUP3 GROUP4 46 VT22 GROUP1 GROUP2 GROUP3 GROUP4
Figure 5−160. Path Finding and Switcher Inputs tables for system shown in Figure 5−159.

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Exclusion Y Line 5−189
XMIT
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
Figure 5−161. Exclusion data table (example).
This table can be used to prevent a particular input from being switched to a given output.

Network Description 5−27 Serial Protocol 5−30
Switcher Description 5−35 Switcher Input 5−48 Switcher Output 5−55
Level set 5−58 Input set 5−62 Output set 5−78 Override set 5−96 Sequence set 5−99 Category set 5−101
Machines 5−135 Machine Control 5−139 Delegation Groups 5−149
Status Display Header 5−150 VGA Status Display 5−151
Figure 5−162. Y Line table (example).
Exclusion 5−188 Y Line
Time Standard G−11 Video Reference G−14 CM VGA Options H−1
VR1−M VR1−S
REV (DATA)
VR1−S VR1−M
VR2−M VR2−S 3
FOR (DATA)
REV (DATA)
VR2−S
VR2−M
The Y Line table is used only with Venus data routers equipped with DM 400 or DM 400A Data Matrix boards in applications where a VTR can be used as a controller (master) on some occasions and as a tributary (slave) on others.
Configuration of this table is described at the conclusion of Appendix L, “Special configuration requirements: Venus DM 400/400A data matrix switching.”

Video Reference Table
These tables are used only for configuration of a CM 4000 System Controller running AccuSwitch software. CM 4000/AccuSwitch installation is described in Appendix G.
This table is discussed in Appendix H.
Configurator

CP 300 24 x 1 Single Bus Control Panel
Each input button of the CP 300 is assigned to a specific source (and the entire panel assigned to a single destination) during the installation procedure described on page 2−38.
Audio−follow−video switching - When one of the 24 input buttons is pressed, a TAKE* command is issued to all levels of the switcher matrix. A status* signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed. See Figure 6−1.
CHG
CHG
VID
A1
A2
Select desired input; button will light when switch
Figure 6−1. CP 300 audio− follow video switching.
CHG
CHG
is made.
A4
A5
Split switching − When the operator desires to take only specific switcher levels, those levels are defined by first pressing one or more of the six breakaway buttons. The TAKE command to the switcher will be executed when an input button is pressed. The switcher will confirm the action by lighting the selected input button. (See Figure 6−2.) If the panel has been configured for sticky levels (as described on page 5−108), the selected level buttons will remain lit after TAKE has been pressed.
Split statusing − To status a specific level of a previous breakaway level switch, select the level to be statused; one of the input buttons will illuminate to indicate the source for that level. If more than one level status button has been toggled on (like A1 and A2), only the lowest level (A1) will be statused.
Figure 6−2. CP 300 Split (breakaway) switching.
* Defined in Glossary Section

Control Panel Operation CP 300 Series
“Protect/lock” output indicator (button flash) − If the output has been protected* or locked* the active input button will flash; this indicates that the input cannot be changed.
For additional protect/lock information − see page 6−12.
Each input button of the CP 310 is assigned to a specific source (and the output buttons assigned to eight destinations) during the installation procedure described on page 2−38.
Audio−follow−video operation - Access to eight switcher outputs is provided by the buttons on the left side of the panel.
After output selection, the input is selected from the bank of 24 buttons in the center of the panel.
Select output, then input
Figure 6−3. CP 310 audio−follow video operation.
Split switching - See Split Switching on page 6−1.
Split statusing − See Split Statusing on page 6−1.
“Protect/lock” output indicator (button flash) − If an output has been protected* or locked* the output button will flash; this indicates that the input cannot be changed.
For additional protect/lock information − see page 6−12.

Control Panel Operation CP 300 Series
CAM1 VTR2 VTR1
CHG OUT
CHG
CHG
CHG
CHG
CHG
CHG
VID
A1
A2
A3
A4
A5
VTR
1 CG
2 NET
3 VCR
4 CAM
5 AUX
EJ SS
PROT
REM
6 FILM
7 PTCH
8 STU
9 TEST
MISC FS SAT TAKE
Figure 6−4. CP 320 Push Button Control Panel (as supplied).
Installation of this panel is shown on page 2−37. For a general description, see page 2−40.
The control panel uses a category/number method for both input and output selection. The operator presses the keypad to select the category, i.e., VTR, CAM, etc. The number selection then designates the individual entry within the category, i.e., VTR1, VTR2, CAM1, CAM2, etc. The Selection window displays the entry as each button is selected. Numbers may contain one or two digits.
To change the output selection, press CHG OUT, then press a category button for the desired category, and a number button for the output number within that category. The control panel output will be changed only when the TAKE button is pressed. A TAKE will not be made, but the switcher controller and output display will change and the new output will be displayed in the Destination window.
Breakaway Level Switching - Inputs are selected as described above. The desired level push buttons are then pressed to initiate switching only on those levels. The TAKE button is then pressed. If the panel has been configured for sticky levels (as described on page 5−108), the selected levels will remain in effect after TAKE has been pressed; i.e., when the next input is entered the appropriate level buttons will come back on.
Video Splits - Combinations of the Breakaway Level buttons and the Category/Number buttons can be used to create a video split. The input and output selections are made as described above.

Control Panel Operation CP 300 Series
Before the TAKE push button is pressed, the desired Breakaway Level push buttons are pressed to designate the levels to be switched.
Another input selection is then made using the category/number push buttons. The desired Breakaway Level push buttons are again selected corresponding to the levels to be added to the switcher TAKE command.
The TAKE button is then pressed, causing the switcher to perform the split, using the two designated inputs from the desired levels.
Protecting the current switcher output - To protect the current output of the switcher, the PROTECT push button is pressed. The PROTECT lamp will remain on to indicate the protect mode.
The protected status will also be displayed by other control panels presently controlling the protected output; if the other panel is a CP 320 the PROTECT button will blink.
Only the control panel that originated the protected status can remove it (the originating panel can be recognized by the steady illumination of the PROTECT lamp). To remove the protected status, press the lighted PROTECT push button. The button light will go out to show the protected status has been removed.
For additional protect/lock information − see page 6−12.
Operation of this panel is the same as the CP 320. The only difference between the panels is that the CP 328 has eight−character display windows while the CP 320 has four−character display windows.
The CP 330 can be configured to operate as a 48 x 1 panel, or, as a 24 x 2 panel with the top row of buttons assigned to one output and the bottom row to another. Operation is much the same as a CP 300, as described on page 6−1.
Figure 6−5. CP 330.
(For installation and configuration instructions, please see page 2−38.)

Control Panel Operation CP 300 Series
Select output...
...then input.
Figure 6−6. CP 330/6 Operation.
Each input button of the CP 330/6 is assigned to a specific source (and the output buttons assigned to six destinations) during the installation procedure described on page 2−41.
Audio−follow−video operation - Access to six switcher outputs is provided by the buttons on the right side of the panel.
After output selection, the input is selected from the bank of 48 buttons on the left side of the panel. This completes the switch.

Control Panel Operation CP 300 Series
Control panels can be tested without affecting switcher operations.
To enter the diagnostic mode, press and hold CHG VID and then press CHG A5: the CHG VID and CHG A1 lights will come on; CHG VID will enable the Button/Lamp Test and CHG A1 will start the Lamp Self−Test.
This test is used to check the proper operation of control panel push buttons. Whenever a button is pressed, that button’s lamp should come on. To exit, press any button twice.
Lamps should come on sequentially, remain on, and then go off. This mode will continue until a button is pressed.
To enter the diagnostic mode, press and hold the output 0 button and then press output 5: the output 0 and output 1 lights will come on; output 0 will enable the Button/Lamp Test and output 1 will start the Lamp Self−Test.
Press and hold CHG VID and then press CHG A5. This will cause the panel to display its device name as defined in the MPK Devices table. To exit, press PROT, or
— Press TAKE to display the panel ID. To exit, press PROT, or
— Press TAKE a second time to enter the diagnostic mode menu. Pressing the CHG OUT button will scroll
through the different diagnostic tests:
To start, press TAKE. To exit, press any button.
To start, press TAKE. Then press every button, checking for duplications. To exit, press any button twice.
To start, press TAKE. All lamps should light sequentially. To exit, press any button.

Control Panel Operation CP 3000
The top row of the display shows output status for four levels. Using the CLEAR key, the bottom row can be toggled between the first page of input override selections and the name of the current output (see Figure 6−7). Input overrides permit single button input selection, eliminating the need to use the category and selection entry keypad for commonly used inputs.
To change the output is being controlled by the panel, please see Display/change Output on page 6−20.
Figure 6−7. Push CLR to toggle display.
1 CG
2 NET
3 SAT
A
EJ VCR
4 CAM
5 REM
B
VTR1 VT1L VT1R VT1T BLK BARS TONE SLNC
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
TAKE CHOP LOCK PROT
MORE CLR MENU LEV
OVERRIDE INPUT SELECTION
Override input selections are made by pressing a Function button below the desired mnemonic. The operator can see other possible selections by pressing MORE. After the operator makes an override selection, the mnemonic and the levels defined for the selected input are displayed in the prompt window. The operator then presses TAKE to send the command to the switcher. The operator can exit the entry mode by pressing CLEAR and the panel returns to the mode it was in before the override was selected.
If entry of a password is requested, please see Passwords on page 6−22.
For information about programming overrides, see page 6−21.

Control Panel Operation CP 3000
The user selects a switcher input by first pressing the desired input category keypad push button. The display menu line will be cleared and the category name will appear (see Figure 6−8).
1 CG
2 NET
3 SAT
A
EJ VCR
4 CAM
5 REM
CAT=VTR SELECT=????
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure 6−8. Display after category has been selected.
The operator then enters the selection number for the desired input; the display will show the primary mnemonic for the input after the word “Select.” Additional detail is given on the bottom row, which shows the input mnemonics for the sources selected on up to four levels. See Figure 6−9. (The appearance and position of each level’s status information is determined by the CP Level set assigned to the panel).
1 CG
2 NET
3 SAT
A
EJ VCR
4 CAM
5 REM
CAT=VTR SELECT=VTR1 VTR1 VT1L VT1R VT1T
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure 6−9. Number has been selected. Ready for TAKE to be pressed.
When TAKE is pressed the command is sent to the switcher matrix. If the TAKE command was successful, the top display row will be updated to reflect the new input status.
If entry of a password is requested, please see Passwords on page 6−22.

Control Panel Operation CP 3000
The protect function prevents an output from being switched by other system control panels. For example, if a VTR is record- ing a program or if the output is feeding a program line, care must be taken to insure that the signal is not switched or disrupted.
The operator presses PROTECT. The system will request verification. (See Figure 6−10.) Press TAKE.
If entry of a password is requested, please see Passwords on page 6−22.
1 CG
2 NET
3 SAT
A
VTR1 VT1L VT1R VT1T PROTECT − PRESS TAKE
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure 6−10.
A blinking “P” will appear in the first character position on the display status line to alert all operators that the output is pro- tected. If another panel attempts to make a switch, the display will indicate the name of the panel that protected the output.
Figure 6−11.
Protect symbol

Control Panel Operation CP 3000
The panel that protected an output is used to unprotect the output.
To unprotect the output, press PROTECT. The protect prompt will appear (See Figure 6−10.) Press TAKE.
If entry of a password is requested, please see Passwords on page 6−22.
The P symbol in the display status line will be removed. The output is now available for control by any panel in the system.
For additional protect/lock information − see page 6−12.

Control Panel Operation CP 3000
The Lock function prevents an output from being switched, including being switched by the panel which set the lock. The output is unlocked by the same panel before a switch can be made.
The operator presses the LOCK push button. The system will request verification (see Figure 6−12). Press TAKE.
If entry of a password is requested, please see Passwords on page 6−22.
1 CG
2 NET
3 SAT
A
VTR1 VT1L VT1R VT1T LOCK − PRESS TAKE
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
TAKE CHOP LOCK PROT
MORE CLR MENU LEV
Figure 6−12.
A blinking “L” will appear in the first character position on the display status line to alert all operators that the output is locked. If another panel attempts to make a switch, the display will indicate the name of the panel that locked the output.
Figure 6−13.
The panel that locked an output is used to unlock the output.
To unlock the output, press LOCK. The display menu line will be cleared and the LOCK prompt will appear (See Figure 6−12). Press TAKE.
Lock symbol

Control Panel Operation CP 3000
If entry of a password is requested, please see Passwords on page 6−22.
The L symbol in the display status line will be removed. The output is now available for control by any panel in the system.
Protect − On Jupiter control panels with a PROTECT button: after a given source has been switched to a given destination, and PROTECT is pressed, the source for that destination can then be changed only at the panel which protected the output.
Lock − On Jupiter control panels equipped with a LOCK button (except MC 3020L): after a given source has been switched to a given destination, and LOCK is pressed, the source for that destination can then be changed only at the panel which set the lock; and only after LOCK is pressed again.
Note 1: If another panel was used to protect/lock the output, the name of the panel will be shown (on panels equipped with alphanumeric displays). The panel names and corresponding device addresses can be found on the MPK Devices table (Figure 5−89); to determine the device address (ID) of a particular panel, please see page 6−21. A panel name such as “Poll 1−075” refers to a party line control panel, in this example, a panel with a polling address of 075 (hex) connected to the first PL 3000 listed in the Network Devices table.
— To permanently change a panel’s password level using the file server, see Setting Password Levels for
Control Panels on page 5−113. This procedure will require downloading a revised set to the controller board.
— To change a panel’s password level to “99” at the panel itself, see Raising Password Level To Maxi-
mum on page 6−22.

Control Panel Operation CP 3000
Chop is a special switching function which automatically alternates inputs to a switcher output. This mode is useful in system test modes and for comparison of switcher inputs.
The matrix chops between the currently selected input and the new chop input. This new input is selected via the normal input selection process, except CHOP is pressed instead of TAKE.
The matrix will then rapidly alternate between the two switcher inputs.
If entry of a password is requested, please see Passwords on page 6−22.
Chop will terminate automatically after approximately two minutes. To terminate the chop manually, select an input and press TAKE.
1 CG
2 NET
3 SAT
A
CHOP CHOP CHOP CHOP BLK BARS TONE SLNC
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure 6−14.
Pathfinding sources cannot be chopped.
Serially−controlled (”Remote switcher”) levels cannot be chopped.
On a single CM 4000 the total number of outputs/levels in chop mode cannot exceed 10 at one time.

Control Panel Operation CP 3000
Normally, a request for a given input will be issued to all levels defined for that input name in the Switcher Input table (page 5−48). However, in some cases it may be desirable to prevent certain levels from switching.
After selecting category and number, the bottom row will display the input mnemonic for each level as selected, i.e., non− blanked. See Figure 6−15.
1 CG
2 NET
3 SAT
A
CAT=VTR SELCT=VTR1 VTR1 VT1L VT1R VT1T
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure 6−15. Number has been selected. Ready for LEVEL to be pressed.
If before pressing TAKE, the LEVEL button is pressed, the operator can toggle off the unwanted levels by pressing the corre- sponding Function key. Additional levels (if any) can be displayed by pressing MORE. See Figure 6−16.
1 CG
2 NET
3 SAT
A
VID VTR1
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
TAKE CHOP LOCK PROT
MORE CLR MENU LEV
Figure 6−16. LEVEL has been pressed, and all levels except video have been toggled off.
After the appropriate levels have been de−selected, TAKE is pressed and the switcher command sent.
If entry of a password is requested, please see Passwords on page 6−22.

Control Panel Operation CP 3000
By using the procedure just described, a completely different input can be selected from one level to another before pressing TAKE.
a. If you want to de−select a level, press the appropriate function key now.
a. If you de−selected a level (in Step 2a. above), you must press the appropriate function key again to blank the entry.
When only one level is to be switched, you may find it convenient to use the following method:
If entry of a password is requested, please see Passwords on page 6−22.
The operator uses MENU and MORE to display the desired menu selection. (See Figure 6−17.) The corresponding Function key is used to select the desired operation.

Control Panel Operation CP 3000
VTR1 VT1L VT1R VT1T DIAG DEF PWD LOG
VTR1 VT1L VT1R VT1T ID Page 3
Figure 6−17. Menu selections.
Selecting STATUS permits the operator to review the current status of all levels of the output controlled by the panel.
The operator presses MENU and then the STATUS soft−key. The display prompt line is cleared and the output status prompt appears. (See Figure 6−18.)
Normally the display status line will display the first four defined output levels. To view the status of other levels associated with the control panel output, press MORE.
Figure 6−18.
The operator presses CLEAR or TAKE to exit the status display mode. The display status line returns to the first group of levels status and the display prompt line returns to the mode it was in when the output status mode was selected.
Page 1 · Page 2

Control Panel Operation CP 3000
Special input selection sequences or macros may be defined via the Sequence Set table (Figure 5−80). On the CP 3000 Switcher Control Panel, the SEQUENCE soft−key allows the operator to access these pre−defined sequences.
The operator presses MENU and then the SEQ soft−key to display the first page of sequence names. The operator then presses the soft−key corresponding to the desired sequence and TAKE.
If entry of a password is requested, please see Passwords on page 6−22.

Control Panel Operation CP 3000
When the Jupiter system is used to control a Venus switcher, the CP 3000 panel can be used for special audio switching modes such as sending a mono signal to both channels of a stereo output, mixing stereo signals into a mono output, and reversing channels. This function requires proper entries to the “Audio” column of the Switcher Description table (see page 5−35).
The display will show the audio pairs in the system. A typical example, based on the table entries shown on page 5−58, is as follows:
Figure 6−19.
In this example, “F1” would be pressed because there is only one audio pair (level 2 “LEFT” and level 3 “RGHT.”) The available audio modes will now appear on the bottom row of the display (Figure 6−20).
If the system has more than four audio pairs, use the MORE button to scroll to the next group of pairs.
Figure 6−20.

Control Panel Operation CP 3000
Left signal on Left channel
Right signal on Right channel
“LEFT” = Left signal on Left channel
Left signal on Right channel
Right signal on Left channel
Right signal on Right channel
Left + Right signals on Left channel
Left + Right signals on Right channel
Right signal on Left channel
Left signal on Right channel “REV” =
Figure 6−21.
The “REV” mode is on the second page (accessible using the MORE key).
Figure 6−22.
This flashing symbol is a caution that the top row of the display does not show true status. In this example, “VT1R” is indicated as the source for the right audio channel, but in fact VT1L is the source. This can be determined by pressing MENU, AUD, and the soft−key for the desired level to bring up the following display:
Figure 6−23.
This display shows true status. The left input channel is switched to both the left and right output channels.
Audio caution symbol

Control Panel Operation CP 3000
The OUTPUT menu selection displays the current logical matrix output to which the control panel is assigned.
The operator presses MENU and then the OUTPUT soft−key. The display prompt line is cleared and the current control panel logical output is displayed. (see Figure 6−24.) The display remains until the operator presses CLEAR or TAKE.
Figure 6−24.
By selecting a category and number before CLEAR or TAKE is pressed, a new output selection is entered in the output display. When TAKE is pressed, the control panel will be assigned to control the new output bus.
Special control diagnostics can be defined by the system controller and executed at the control panel. The operator interaction and panel displays will be determined by the actual diagnostic selected.
The operator presses the MENU mode selection push button, then the MORE key to display the control panel DIAGnostics selection. The operator presses the DIAGnostics soft−key and the first group of options is displayed. The operator presses the soft−key for the desired selection and then follows the instructions on the control panel display.
Upon completion of the selected diagnostic, the control panel returns to the DIAGnostic selection menu. The operator may then select another diagnostic or press the CLEAR key until the panel returns to the default control panel mode.
The display self−test mode is used to check the proper operation of the vacuum fluorescent (VF) character display. When the test mode is started, a pattern of all position display characters will be written to each character position.
The display self−test will continue until the operator presses the CLEAR or TAKE push buttons. The panel will then return to the DIAGnostic selection menu. Pressing the CLEAR push button again, will return the panel to mode it was in before the diagnostic menu was selected.
The keypad self−test mode is used to check the proper operation of control panel push buttons. When the test mode is started, the display will show the definition of each control panel push button as it is pressed. This display will show the button name/ address and the currently defined panel function name.
The keypad self−test mode will continue until the operator presses the CLEAR or TAKE push buttons twice.

Control Panel Operation CP 3000
The control panel overrides permit a quick selection of switcher inputs and level selections. The overrides must first be defined on the Override Set table (Figure 5−78). For each definition, there is a choice of allowing or not allowing the override to be edited from the front panel.
The operator edits the override by first selecting a switcher input via the category and selection keypad. If level selection is required, use the LEVEL menu selection mode. In other words, input selection must be complete but TAKE is not pressed.
The operator then presses MENU and MORE to display the DEFINE override soft−key. This displays the first page of existing override names. The operator then selects the override to be edited by pressing the corresponding function key. The MORE push button is pressed if the desired override name is on another page.
If entry of a password is requested, please see Passwords on page 6−22.
Important: This procedure does not change the name of the override as established by the Override Set table. This could result in a situation where the operator selects CAM1 but gets VTR5. For overrides that will be allowed to be to be edited from the front panel, it is a good practice to use generic names such as “Usr1” or “Ovr1”on the Override Set table.
The panel ID menu selection displays the system address used to select and service this control panel. The ID is determined at time of panel manufacture and cannot be changed by the operator.
The operator presses MENU, MORE (twice), and then the ID soft−key. The display prompt line is cleared and the current control panel identification is displayed. (See Figure 6−25.) The display remains until the operator presses CLEAR or TAKE.
Figure 6−25.

Control Panel Operation CP 3000
If a password is requested during entry of a command, the output about to be affected has a password level higher than that of the panel. After entry of a higher−level six−digit password, the command can be completed by pressing TAKE; however, the panel will then revert to its previous password level.
The PWD function permits the operator to log on to the control panel, thus raising the password level of the panel to the same level as the operator’s password—and this level will remain in effect until the operator uses the Logout procedure described below.
Press MENU, MORE, and PWD. The display prompt line is cleared and the enter password prompt appears. (See Figure 6−26.) Enter your six−digit password (as entered on the Password Table) via the keypad and press TAKE. You have three tries to enter a valid password.
Figure 6−26.
The password level of a panel can be raised temporarily to 99 (the maximum possible) directly at the panel. This avoids using the file server and downloading a modified set to the controller board.
The operator presses MENU, MORE, and PWD. The display prompt line is cleared and the enter password prompt appears. (See Figure 6−26.) The operator then enters the six−digit Jupiter password and presses TAKE. (The Jupiter password, which is factory set at 999999, is discussed in more detail on page 5−22.) With a password level of 90 or higher, the panel’s PRO- TECT and LOCK keys can be used to force unprotect/unlock any output.
To restore the panel to its normal password level, see LOG immediately below.

Control Panel Operation CP 3000
If the Enter New Password or Raising Password Level functions just described have been used and you later wish to log out to prevent unauthorized operation, press MENU, MORE, and LOG. The panel will revert to the password level defined on the MPK Devices menu (page 5−107).

Control Panel Operation CP 3010
The CP 3010 can be used as a companion to the CP 3000 Switcher Control Panel (described immediately below) or to the MC 3000 Machine Control Panel (see page 6−131).
For multi−bus control the desired source can be selected on the CP 3000; the CP 3010 would then display the names of up to eight destinations, beneath which are the corresponding TAKE keys; one of these would be pressed to complete the switch. 20 pages of eight destinations each can be scrolled to display up to 160 possible destinations. To return to page 1, press the UP and DOWN arrows at the same time.
CAM3 MON3
CAM2 MON2
VTR1 VTR2
>
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
Figure 6−27. CP 3010 Expansion panel.
The process of assigning outputs to the expansion panel is the same as assigning the output to be controlled by the CP 3000, except that TAKE is pressed on the expansion panel rather than on the CP 3000:
Deleting an Output on TAKE Key
To delete an output that has been dynamically assigned to the expansion panel, use the CP 3000 to select an output that is not defined and press the appropriate TAKE key on the expansion panel.

Control Panel Operation CP 3010
Outputs can also be assigned permanently, as described on page 5−79.
Note: If an output is permanently assigned to a CP 3010 button, but that output is later removed from the CP Output table, and the new set downloaded, the CP 3010 will continue to display the name of the output until the output is manually deleted. To do this, select an output that is not defined and press the appropriate TAKE key on the expansion panel.
When the CP 3010 is used as an expansion panel for a CP 3000 control panel, Start/Stop machine control can be provided by the and > buttons.
Configuration for machine control applications and the method by which machines are assigned to the panel are discussed on page 5−148.

Control Panel Operation CP 3020
Installation of this panel is shown on page 2−37. See also page 2−43.
The CP 3020 is a single bus control panel that can select one of 20 inputs using the button−per−input technique. The number of inputs can be increased by means of the CP 3021 Expansion Panel.
C1 C2 C3 C4 T1 T2 R1 R2 NT V1 V2 V3 V4 V5 SA SB E1 E2 E3 LOCK CHOP
LO1 LO2 LO3 LO4 81 M1 M2 M3 M4 M5 LR LS P1 P2 P3
Figure 6−28. CP 3020 Push Button Control panel (top) with CP 3021 Push Button Expansion panel.
The LOCK button can be pressed at any time to lock* the output controlled by the panel; the button will illuminate to show that the lock is in effect. Press LOCK again to unlock.
If the LOCK button is flashing, the output has been locked by another panel. The panel used to lock the output must also be used to unlock the output. For additional protect/lock information − see page 6−12.
To chop* between two inputs, select the first input, then press CHOP, then the second input. The CHOP button will illuminate to show that the output is in chop mode. To terminate the chop, select another input. For additional chop information − see page 6−13.
See page 2−59.
*see Glossary § A complete copy of this manual is also available on the Technical Publications Library CD−ROM supplied with the manu-
al you are now reading.

Control Panel Operation CP 3800
1 CG
2 NET
3 SAT A
5 VCR
6 CAM
B EMER REM
1 2 3 4 5 6 7 8
ride SEQ Audio Menu
Prot Dest Level Over
Figure 6−29.
The CP 3800A is a universal, eight−character mnemonic, switcher and machine control panel. Display and operating modes include:
When operated in the “multiple destination mode,” the CP 3800A can be used to control from 1 to 80 destinations, with the names of eight of those destinations (and the status for each) on display simultaneously. In the “single destination mode,” one destination is selected for control, and the display window shows the status for each level of that destination (video, left audio, right audio, etc.).
The push buttons are capable of both green and red back lighting, with green generally used to show a selected function and red to indicate an operational mode in progress. Relegendable buttons are used to allow user−defined categories.
Note: This control panel uses an eight−character “CP 3800” type CP Level set (page 5−58), CP Input set (page 5−62) and CP Output set (page 5−78). The panel is also defined in the MPK Devices table (page 5−107), and if used for machine control, the Machine Control Devices table (page 5−135). It can also use custom CP Category sets (page 5−101).

Control Panel Operation CP 3800
In general, the top row of the display is used to show status or operational modes, error messages, page numbers and instruc- tions. The bottom row shows selection items corresponding to the row of soft keys under the display (i.e. levels, destinations, etc.).
Camera_1 Camera_2 Studio_a Clr_Bars VTR_02 NetworkA NetworkA Black
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
F1 F2 F3 F4 F5 F6 F7 F8
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎÎ
Figure 6−30.
Eight soft keys are arranged across the bottom of the display to correspond with the display space above each button. These buttons are dynamically reassigned depending upon the mode selected in the Menu Mode Group (Figure 6−32) and upon the defined CP sets for the panel. Destination selections and menu selections illuminate in green.† Pending level, audio, or config- uration selections illuminate in red as described in the appropriate sections below.
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
UNDO
ÎÎ
ÎÎ
TAKE
ÎÎ
Figure 6−31.
The up/down buttons (Figure 6−31) provide scrolling control over all defined menu pages. They will not scroll to any unde- fined pages except in the case of adding destination assignments and defining overrides and sequences; in this case, they will allow access to one blank page beyond any page that currently has assignments. Up to 20 pages are allowed. A single digit in the upper left denotes the page number (1−9, 0 for page 10).
The UNDO button returns the panel and any affected outputs to the state it was in prior to the last TAKE. Successive selection of this button will allow toggling between two selections (allows undoing an undo). The undo function will also undo Over- rides.
† In this discussion, “illuminate in green” refers to high (bright) green. “Low” green is always on.

Control Panel Operation CP 3800
The TAKE button executes any change(s) which has(have) been selected. When any action has been selected that requires a TAKE to be completed, this button will illuminate in red to indicate that it is “armed.”
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
LEVEL SEQ OVER RIDES AUDIO MENU DEST
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
Figure 6−32.
The menu mode group determines the operational mode of the panel. If no buttons are illuminated, the panel is in “multiple destination” state, allowing source assignments to any of the destinations shown on the menu. The additional operational modes are:
When any mode is selected, it will illuminate green to indicate that new mode. If a definition is in progress (i.e. defining a sequence) the mode will illuminate in red to indicate a process in progress.

Control Panel Operation CP 3800
ÎÎ
CLEAR PROT/
ÎÎÎ
LOCK
ÎÎ
Figure 6−33.
The bottom two buttons below the Mode group select protection or locking (PROT/LOCK) and clear category/number selec- tions and/or cancel ongoing definitions (CLEAR). Protect/lock mode is described on page 6−61.
The CLEAR button will clear any category/number selection if one is in progress. If none is in progress the CLEAR button will return the panel to either single or multiple destination operational mode in increments of embedded menus or operations − each button press will escape back one operational level.
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
1 VTR
2 CG
3 NET
A SAT
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
4 VCR
ÎÎÎ
5 CAM
ÎÎÎ
6 REM
ÎÎ
EMER
ÎÎÎ
B
LEVEL
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
FILM
PATCH
OVER RIDES
STU
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
FRST
ÎÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
TEST
ÎÎ
MISC AUX
ÎÎÎ
AUDIO
ÎÎÎ
ÎÎ
STILL
ÎÎÎ
D
Figure 6−34.
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎÎ
CATEGORY AND NUMBER GROUP
Twenty buttons in a 4 high by 5 wide array form a traditional category and number group.
As an example, if the panel is configured to use category prompting, during source assignment all valid categories will illumi- nate in green. Once a category has been selected, all valid numbers will illuminate in red. Once a category and one digit have been selected, only remaining valid numbers will remain lit.
This panel can be system defined (at the file server) for:
— Multiple Destination Mode operation, front−panel selectable to Single Destination mode; or,
— Single Destination Mode only operation.
For front−panel selectable, Multiple or Single Destination Mode operation, a “Y” is placed in the Expansion column of the MPK devices table (see “Expansion” on page 5−109). For Single Destination Mode only operation, an “N” is entered.

Control Panel Operation CP 3800
This mode, sometimes referred to as “multi−bus” or “full−matrix control” mode, is in effect when none of the “mode” buttons are illuminated. This mode displays the top level status for eight destinations.
The first line contains the status of those eight destinations (defined name in the CP Input set for the selected source) plus a page number in the upper left hand corner. The second line of the display will show up to eight destinations.
Camera_1 Camera_2 Studio_a Clr_Bars VTR_02 NetworkA NetworkA Black
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
F1 F2 F3 F4 F5 F6 F7 F8
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎÎ
Figure 6−35. Example Multiple Destination Display Page − Home
From this page you can:
You can also change Protect/Lock status, level selections, and audio modes once a destination(s) has been selected. Those operations are described in the appropriate separate sections in this document.
Scrolling to other pages is achieved with the Up/Down Arrows in the Menu Control Group. A maximum of 20 pages are acces- sible, each page numbered in the upper left.
Status · Page · Output

Control Panel Operation CP 3800
Selecting Destination(s) and Making a Switch
Select the soft key under the desired destination (first scrolling to a different page if required). That soft key will illumi- nate green, and if Category Prompting is enabled, valid categories in the Category/Number Group will also illuminate green.
Category/number selections will be ignored until a soft key has been selected. Reselecting an illuminated soft key button will toggle it off and cancel the operation. Selecting another soft key will add destinations to be changed to the same source; up to all 80 destinations may be simultaneously selected. Selecting CLEAR will cancel all illuminated destina- tion soft keys and return the panel to multiple destination home state. If the panel has not been configured for prompting (page 6−51), operation will be identical, except the category and number keys will not illuminate.
Initiate a source selection by selecting the desired category from the illuminated choices; selection of an invalid category will have no effect. If a destination has not yet been selected, you will have the opportunity to select one now. Upon selection of one of the illuminated Category buttons, all valid numbers will illuminate in red; the display will change to entry mode. Appropriate updates to the display will occur as in the CP 3000 entry process, with the additional display of the “Number =” selection as shown below. The selected destination soft key(s) will also change to red to indicate a selection in process.
Category = Vid_Tape Number = New Source =
Figure 6−36. Example Single Destination Assignment Display Page − Category Selected.
As valid numbers are entered, the display will update appropriately as defined in the sets. Selection of an invalid number (not illuminated) will have no effect. If the panel has not been configured for prompting, operation will be identical, except the category and number keys will not illuminate.
Examples of numeric entries are shown below:
Category = Vid_Tape Number = 1 New Source = VTR_0001
Figure 6−37. Example Single Destination Assignment Display Page − Category & Digit Selected.
Once a category and one digit have been selected, only remaining valid numbers will remain lit.
Destination = PRODCTN4 · Destination = PRODCTN4

Control Panel Operation CP 3800
Category = Vid_Tape Number = 12 New Source = VTR_0012
Figure 6−38. Example Single Destination Assignment Display Page − Category & Two Digits Selected.
If multiple destinations have been selected, the top line will display as many as possible (up to 6) and then indicate addi- tional destinations with ellipses (...).
Destination = PRODCTN1, PRODCTN2, PRODCTN3, PRODCTN4, ENGINRNG, EXTFEED9
Category = Vid_Tape Number = 12 New Source = VTR_0012
Figure 6−39. Example 6 Multiple Destination Assignment Display Page − Category & Two Digits Selected.
Destination = PRODCTN1, PRODCTN2, PRODCTN3, PRODCTN4, ENGINRNG, EXTFEED9,...
Category = Vid_Tape Number = 12 New Source = VTR_0012
Figure 6−40. Example Over 6 Multiple Destination Assignment Display Page − Category & Two Digits Selected.
The source assignment operation may be completed using the TAKE button any time a valid selection has been made. This will be indicated by the presence of a source name in the display after the display of “New Source =” and the fact that the TAKE button will be illuminated.
Selection of the CLEAR button at any time during the category/number process will place the panel back in “ready for category” mode. A second selection of clear will cancel the operation and revert to home state.
At any time after destinations have been selected and prior to selecting TAKE, levels and audio modes may also be se- lected as described in the appropriate section below.
Destination = PRODCTN4

Control Panel Operation CP 3800
Adding or Changing a Destination Soft Key Assignment
A destination may be added to any unused location in the display. One additional page will be available when adding destina- tion assignments.
Changing a destination that has already been defined on the panel is also possible.
Existing Destination STUDIO_A Is System Defined And Can Not Be Changed
Category = Vid_Tape Number = New Source =
Figure 6−41. Example Destination Assignment In Process − Defined Destination Warning.
Adding or changing a destination is achieved by the following sequence:
The button will blink red. The displayed change menu will appear:
1 Changing Destination − Use Up/Down Buttons and Soft Key to Select Position
Figure 6−42. Example Destination Assignment − Change Menu.
All user defined locations will illuminate in green.
The selected soft key will change to red. The display will update to indicate that a destination assignment is in process, Category and number keypad entry, CLEAR, TAKE and display function as already described:
Category = STUDIO Number = 3 New Destination = STUDIO_C
Figure 6−43. Example Destination Assignment In Process − Category & Two Digits Selected.
Assign Destination

Control Panel Operation CP 3800
When assigning a destination to a soft key position for the first time, selecting the TAKE button will complete the assign- ment and clear all illuminated buttons. The panel will remain on the current page, with the page number displayed in the upper left corner.
To change an eligible destination, one additional TAKE after the following warning display will be required to complete the operation:
Category = STUDIO Number = 3 New Destination = STUDIO_C
Figure 6−44. Example Destination Assignment In Process − Confirming replacing a destination.
Destinations may be erased if no longer needed from the multiple destination home mode with the following sequence as in changing a destination.
The display will update to indicate that a destination assignment is in process.
If CLEAR is selected before any keypad operation has been initiated, that soft key destination will be marked for erasure and the user will see the following display:
Figure 6−45. Example Destination Erasure In Process − Selected destination blinking.
This will complete the clear for the selected destination, returning the panel to multiple destination home state. Selecting CLEAR a second time will cancel the operation, also returning the panel to multiple destination home state. Reselecting the blinking DEST button will cancel the operation and return the panel to the multiple destination home state.

Control Panel Operation CP 3800
Entering Single Destination Mode
This mode displays multi−level status for a single destination.
The DEST button will illuminate in green.
— If the desired destination has already been assigned to a soft key, select the key.
— If the desired destination has not been assigned to a soft key, press DEST again. Button should now be flash-
ing red. Select a soft key that is lit high green (i.e., one that is front−panel assignable). Select a category and number; press TAKE. (If the button has already been assigned you will need to press TAKE again.) Then go back to Step 1.
The DEST button will remain illuminated in green to indicate single destination mode.

Control Panel Operation CP 3800
ÎÎÎ
DEST
ÎÎÎ
SINGLE DESTINATION MODE (“SINGLE−BUS CONTROL”)
This mode displays multi−level status for a single destination. The DEST button remains illuminated in high green.
As explained previously, this panel can be system defined at the file server for Multiple/Single Destination Mode operation, or Single Destination Mode only operation. For front−panel selectable, Multiple or Single Destination Mode operation, a “Y” is placed in the Expansion column of the MPK devices table. For Single Destination Mode only operation, an “N” is entered.
— If the panel is system−defined for Single Destination Mode only operation, the “DEST” button is always illu-
minated in high green (cannot be turned off by the operator).
— If the panel is system−defined for Multiple/Single Destination Mode, selection of Single Destination Mode is
described on page 6−36.
1 Destination = PRODCTN4 Source = VTR_0001
Figure 6−46. Example Single Destination Mode Display Page − Home State.
As shown in the above example, the first line of Single Destination home state shows the destination mnemonic, the source mnemonic, and the page number. The second line shows status for that destination.
Page numbers here are only provided if more than eight levels exist. Levels are shown on the second line as defined for the destination.
When in this mode, source assignments can be made at any time, so if the panel supports prompting (page 6−51), valid catego- ries are also illuminated in green.
From this page you can:
A user can also change a Protect/Lock status, level selections and audio modes. Those operations are described in the ap- propriate separate sections in this document.

Control Panel Operation CP 3800
ÎÎÎ
DEST
ÎÎÎ
SINGLE DESTINATION MODE (CONT’D)
Scrolling to Other Pages
Scrolling to other pages is achieved with the Up/Down Arrows in the Menu Control Group. Only pages containing levels will be accessible. The presence of page numbers in the upper left corner indicate that more than eight levels have been defined for the selected destination.
— If the button changes to red, the panel is system−defined for Single Destination mode. The available destina-
tion category buttons will illuminate in green. Go to Step 2.
— If the button lamp goes to low green, the panel is system−defined for selectable Multiple/Single Destination
mode. Go to Step 1a.
a. Press DEST again.
— If the desired destination has already been assigned to a soft key, select the key. This completes the proce-
dure.
— If the desired destination has not been assigned to a soft key, press DEST again (3rd time). Button should
now be flashing red. Select a soft key position (front−panel assignable positions are indicated by high green). Go to Step 2.
Current Destination = PRODCTN4
Category = Number = New Destination =
Figure 6−47. Example Destination Assignment Display Page − No Selections made.

Control Panel Operation CP 3800
ÎÎÎ
DEST
ÎÎÎ
SINGLE DESTINATION MODE (CONT’D)
After a valid category has been selected, the display will reflect the choice and if prompting is enabled, the valid number buttons will illuminate in red in the category/number group.
Current Destination = PRODCTN4
Category = Vid_Tape Number = New Destination =
Figure 6−48. Example Destination Assignment Display Page − Category Selected.
Numbers may be selected as indicated by valid red illumination.
Current Destination = PRODCTN4
Category = Vid_Tape Number = 1 New Destination = VTR_0001
Figure 6−49. Example Destination Assignment Display Page − Category & One Digits Selected.
Current Destination = PRODCTN4
Category = Vid_Tape Number = 12 New Destination = VTR_0012
Figure 6−50. Example Destination Assignment Display Page − Category & Two Digits Selected.
The destination selection operation may be completed using the TAKE button any time a valid selection has been made. This will be indicated by the presence of a source name in the display after the display of “New Destination =” and the fact that the TAKE button will be illuminated.
If the panel leaves the Single Destination mode (DEST button goes off), re−enter the mode by pressing DEST again and selecting a destination to be controlled.
Pressing CLEAR at any time during the entry process will return the panel to the Destination Assignment No Selections Made Mode. Selection of CLEAR at that state or reselecting the red DEST button at any time will cancel the operation and return the panel to Single Destination Mode Home State.

Control Panel Operation CP 3800
ÎÎÎ
DEST
ÎÎÎ
SINGLE DESTINATION MODE (CONT’D)
Making a Switch
To select a new source, the user enters Source Assignment Mode by selecting any of the green illuminated Category buttons. The display will update as shown below and if prompting is enabled (page 6−51), the available source number buttons will illuminate in red.
Destination = PRODCTN4 Current Source = VTR_0001
Category = Vid_Tape Number = New Source =
Figure 6−51. Example Single Destination Source Assignment Display Page − Category Selected.
Numbers may be selected as indicated by valid red illumination
Destination = PRODCTN4 Current Source = VTR_0001
Category = Vid_Tape Number = 1 New Source = VTR_0001
Figure 6−52. Example Single Destination Source Assignment Display Page − Category & One Digit Selected.
Destination = PRODCTN4 Current Source = VTR_0001
Category = Vid_Tape Number = 12 New Source = VTR_0012
Figure 6−53. Example Single Destination Source Assignment Display Page − Category & Two Digits Selected.
The source assignment operation may be completed using the TAKE button any time a valid selection has been made. This will be indicated by the presence of a source name in the display after the display of “New Source =” and the fact that the TAKE button will be illuminated.
Pressing CLEAR at any time during the entry process will return the panel to the Destination Assignment No Selections Made Mode. Selection of CLEAR at that state or reselecting the red DEST button at any time will cancel the operation and return the panel to Single Destination Mode Home State.
At any time prior to selecting TAKE, levels and audio modes may also be selected as described in the appropriate section below.

Control Panel Operation CP 3800
ÎÎÎ
LEVEL
ÎÎÎ
LEVEL SELECTION MODE (“SPLIT” OR “BREAKAWAY” SWITCHING)
This mode is in effect when the “LEVEL” button is illuminated.
Level selection mode can be entered at any time. This mode is accessed either by directly selecting the LEVEL button or by selecting any level soft key when in single destination mode. This mode is indicated by the illumination of the LEVEL button: green if all levels are selected, red if any subset of levels are selected. The display will also reflect this mode as shown below:
1 VIDEO LEFT RIGHT TIMECODE DATATX DATARX AES_LEFT AESRIGHT
Figure 6−54. Example Level Selection Mode Display Page.
From single destination mode, pressing any soft key will present this display. The behavior of the button (turning “on” or “off”) will depend upon the panel type. If defined with Sticky Levels in the panel Configuration menu (page 6−50), the button will change from its previous state while other buttons remain as they had been selected. Otherwise, the button will light in red and all other levels will be deselected. Additional levels can also be selected from this state. Pages can be scrolled if need be to access additional levels.
Entering Level Selection mode from multiple destination mode or when LEVEL is selected starts with all soft keys “off” unless the panel was defined with sticky levels. In that case, entering Level Selection mode displays last selected levels by illuminating the appropriate soft keys.
As many levels may exist (up to 64), it may be desirable for the operator to start this selection from all levels “on” rather than all levels “off.” Double punching the LEVEL button will place the panel in that state (i.e. level selection mode with all levels turned on). Note that all levels will switch when level soft keys are either all on or all off.
If accessed from single destination mode, the levels display line (line 2) does not change. If accessed from multiple destination mode, all valid levels for all destinations selected will be displayed. The operator may select levels which have no impact for some selected destinations; the level soft key will blink red when this condition occurs. When a take will only impact that selected level where it is valid, in addition to blinking the soft key, the display will temporarily show the following message until the next selection or time−out:
1 Level Selection Mode − LEVEL SELECTED NOT VALID FOR ALL DESTINATIONS
Figure 6−55. Example Level Selection Mode Display Page − Valid Level Warning Display.
Any selected level soft keys remain illuminated in red when returning to single destination mode.

Control Panel Operation CP 3800
ÎÎÎ
LEVEL
ÎÎÎ
LEVEL SELECTION MODE (CONT’D)
The soft keys return to their selected destination states illuminated in green when returning to the multiple destination mode. The LEVEL button blinks in red to indicate that breakaway levels have been selected. It can be reselected at any time to ex- amine the state of the level soft keys.
— Press LEVEL twice and de−select level(s).
( 4. Optional: Repeat Steps (2) and (3) above if another level and source need to be switched with a single TAKE. )
— Press LEVEL twice and de−select level(s).
( 3. Optional: Repeat the above steps if another level and source need to be switched with a single TAKE. )
−or− · −or−

Control Panel Operation CP 3800
ÎÎÎ
AUDIO
ÎÎÎ
AUDIO CONTROL MODE (VENUS SPECIAL STEREO SWITCHING)
This mode is in effect when the “AUDIO” button is illuminated.
This mode is accessed by directly selecting the AUDIO button. If no such levels have been defined, the button will have no effect. This mode is indicated by the illumination of the AUDIO button: green if only normal audio mode(s) selected, red if any audio level(s) is set to other than normal. The display will also reflect this mode as shown below:
1 Left Right X−left X−right
Norm−L Norm−R Norm−L Norm−R
Figure 6−56. Example Audio Selection Mode Display Page − Normal Modes Only.
In this mode, any appropriately defined stereo levels appear in the top line in the same position they appear in Level display. The panel will automatically display the first page with defined audio levels. The bottom line shows what audio mode is se- lected.
Selecting the soft key under any level will consecutively cycle through valid audio modes. For a left channel these would be: Revrs−R, Mix, and back to Norm−L. For a right channel these would be Revrs−L, Mix, and back to Norm−R. In the following example, three of the four levels have been changed from normal and those respective soft keys will be illuminated in red:
1 Left Right X−left X−right
Revrs−R Norm−R Mix Revrs−L
Figure 6−57. Example Audio Selection Mode Display Page − Various Modes Selected.
Deselecting the AUDIO button returns the panel to exactly whatever state it was in prior to entry into this mode. Note that this can even occur in the middle of a category/number operation. If no additional operations are needed, TAKE can also be selected at this time (if illuminated) to complete any pending operation.
The soft keys return to their previous states when returning to the previous mode. The AUDIO button blinks in red to indicate that special audio mode will be in effect for the next take. In multiple destination mode, special Audio Mode status will also be shown for each destination displayed in the 1st character position with a blinking “A.” When in single destination mode or Levels mode of multi−destination mode, the 1st character position of each level will also reflect special audio status of that level with the blinking “M” for Mix, or “R” for Reverse. The AUDIO button can be reselected at any time to examine the state of the audio levels.
The state of the Audio modes depend upon the panel type. If defined in the panel configuration menu with sticky audio, the audio mode selections will remain in effect across any number of takes, if not, audio modes reset after each take.

Control Panel Operation CP 3800
ÎÎÎ
AUDIO
ÎÎÎ
AUDIO CONTROL MODE (CONT’D)
To Perform a Special Stereo Switch:
NORM L − Use left audio for this channel
LEFT LEFT (Left signal on Left channel)
MIX − Mix left and right on left channel
LEFT (Left + Right signals on Left channel)
REVERSE R − Cross right channel signal over to left channel
LEFT (Right signal on Left channel)
3(b). Toggle the Right channel soft key to the desired mode:
NORM R − Use right audio for this channel
RIGHT RIGHT (Right signal on Right channel)
MIX − Mix left and right on left channel
RIGHT RIGHT (Left + Right signals on Right channel)
REVERSE L − Cross left channel signal over to right channel
RIGHT (Left signal on Right channel)

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE
This mode is in effect when the “MENU” button is illuminated.
Menu mode is used to access less frequently needed functions, run diagnostics, and to configure the panel. Select the MENU button to enter this mode. That button will illuminate in green and the panel will present the following display:
Menu Page − Select Desired Soft Key
Figure 6−58. Top Level Menu Page.
From this menu any of the five choices presented may be selected on the appropriate green illuminated soft keys.
When this soft key is selected, the panel goes into one of two modes, depending upon whether it was in single or multi destina- tion mode prior to the selection of the menu button. The MENU button will change to red and remain illuminated.
If no machine control has been defined for the panel, “VTR CNTL” will not be selectable and the following will be displayed:
Machine Control NOT Defined For This Panel
Figure 6−59.
Single Destination VTR Control
When the CP 3800A has been configured for machine control (using the Machine Control table, page 5−139) and if a valid controlled VTR source has been switched to the destination, the panel will present the following menu display:
Destination = VTR_0001 Source = VTR_0002
PLAY STOP READY CUE MARK REWIND F FWD RECORD
Figure 6−60. Example Single Destination Machine Control Page.
From this page, any of the displayed machine control functions can be selected. “Record” is selected by pressing both the PLAY and RECORD soft keys. All other commands are accessed by single button selections.

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
If a source is selected which does not support machine control the display will indicate as follows:
Destination = PRODCTN4 NO MACHINE CONTROL DEFINED for
PLAY STOP READY CUE MARK REWIND F FWD RECORD
Figure 6−61. Example Single Destination Machine Control Page − No Machine defined warning.
If the destination supports machine control but the machine does not respond, the display will indicate that with the following display:
Destination = PRODCTN4 Source = VTR_0002 MACHINE IS OFF LINE
PLAY STOP READY CUE MARK REWIND F FWD RECORD
Figure 6−62. Example Single Destination Machine Control Page − Not on Line Warning.
To leave this mode, the user selects the red illuminated MENU button and will return to normal single destination operation mode.
Multiple destination VTR Control
If VTR control is selected from the menu page, and menus entered from multi−destination mode, the Menu button will illumi- nate in red and the panel will display as follows:
1 VTR_0123 VTR_0124 VTR_0125 VTR_0126 Test1 Bars VTR_0333 VTR_0456
STOPPLAY PLAYSTOP OFF LINE SHUTTLE NO TAPE STOPPLAY
Figure 6−63. Example Multiple Destination Machine Control Page.
Machines which are stopped will report “STOPPLAY” with “STOP” blinking. Machines which are playing will report “PLAYSTOP” with “PLAY” blinking. Sources that are not responding will show the words OFF LINE and sources that are not interfaced will show no status. If the device is in some other mode such as shuttling, the display will so indicate but no control is offered. Wherever PLAY / STOP appears, the associated soft key will illuminate in green. Each successive selection of this button will toggle the play/stop condition of the device.
To leave this mode, select the red illuminated MENU button and the panel will return to normal multiple destination operation mode.
Scrolling to other pages is achieved with the Up/Down Arrows in the Menu Control Group. Presence of page numbers indicate that more than eight outputs have been defined for the panel.

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
Diagnostics
Upon selection of the Diagnostics soft key of the menu page, the panel will enter the firmware diagnostics mode and the fol- lowing display will be shown:
MENU
Figure 6−64. Menu Diagnostics Select Page.
Press the up and down arrows to scroll to the desired selection. Press TAKE to execute the desired selection.
To exit the diagnostics mode press CLEAR at any time. (It may be necessary to press CLEAR twice.)
Info displays the panel’s Application (PROM) version. Pressing UP will advance to the Xilinx FPGA* version, the security flag setting, the Variant version, and the PCB (hardware) version. Press CLEAR to exit.
When selected, this option displays the current baud rate for the panel. Press DOWN to decrease the baud rate, UP to increase. Available baud rates are: 38400, 19200, 9600, 4800, 2400, and 1200. Pressing TAKE will program the changed setting; CLEAR will cancel.
If the message “Remove MPK conn” appears, the MPK cable must be disconnected before the change can be made.
The baud rate must agree with the setting for the CM 4000 port used by the panel (see Serial Protocol on page 5−30).
When selected, this option displays the current MPK hexadecimal address for this panel and permits entry of a new address (the MPK cable must be disconnected before making a change). Use the UP and DOWN arrows to select the desired number (0−9) or letter (A−F) and press TAKE to advance to the next position. (You can also use the numeric key pad and the ABCD keys to enter numbers 0 through D.)
The address must agree with the setting for the panel on the MPK Devices table (see page 5−107).
Pressing TAKE will program the newly entered address; CLEAR will cancel.
* Defined in Glossary section
Info · Baud Rate · Panel ID

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
This diagnostic, which requires the panel to be disconnected from the MPK data cable, is used for factory testing of the MPK port.
Pressing any key will exit the test and return the panel to the Diagnostics menu.
This option allows the user to change the “Low” and “Medium” levels of green button illumination, the “Low” and “Medium” levels of red button illumination, and the level of LED (display character) illumination. The “High” button levels are not ad- justable.
The “Low” green level is used for normal button lighting. “High” green and “high” red are also used, but these are not adjust- able.
The brightness of the LED display characters can also be adjusted.
For each setting, use the UP and DOWN buttons to change to the desired brightness and press TAKE. Press CLEAR to exit.
This test rotates through the button lamp and Display tests continually. Press CLEAR to cancel.
This diagnostic displays the number of each button as it is pressed. Pressing the TAKE key will change the lamp color. Press- ing CLEAR twice exits.
This test cycles through and displays all legal characters. The test will stop after one cycle. Pressing CLEAR exits.
This test cycles through the button lamps (LEDs) and illuminates them in green and then red. The test will stop after one cycle. Pressing CLEAR during this test will cancel this test and return the panel to the beginning of the current diagnostic. Pressing CLEAR again will return the panel to the Home mode.

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
Chop
This menu selection allows chopping alternatively between the previously selected source and a new source. Upon selection of the CHOP soft key, the MENU button will illuminate in red and the following display will be shown:
Enter Input to CHOP and Press TAKE to Complete
Category = Vid_Tape Number = ?? New Source =
Figure 6−65. Menu Diagnostics Select Page.
The user may then set up any kind of basic or complex source selection per normal operation, with the exception of audio modes. Irrelevant keys will be ignored at this time; i.e. MENU, DEST, SEQ, OVERRIDES, AUDIO, PROT/LOCK.
When the desired source selection is complete, press the TAKE button and the CHOP will begin. The panel will return to home mode and the MENU lamp will extinguish.
Chop mode is indicated by a flashing letter “c” in the status display. In single destination mode, the “c” will appear on each level that is in chop mode.
For additional chop information − see page 6−13.

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
Config
Upon selection of the Configuration soft key of the Menu page, the MENU button will illuminate in red and the following display will be shown:
Menu Configuration Page − Select Desired Soft Key
Output Level Audio Prompting
Figure 6−66. Menu Configuration Select Page.
Pressing the red MENU button again, or CLEAR, will exit the configuration mode.
On selection of the Output soft key in the configuration menu, the following display will appear:
Press TAKE to turn Sticky Outputs OFF − Clear to Exit
Figure 6−67. Menu Configuration − Sticky Outputs Page.
Pressing TAKE will cause the sticky output mode to toggle. CLEAR will return the panel to the previous page.
On selection of the Level soft key in the configuration menu, the following display will appear:
Press TAKE to turn Sticky Levels ON − Clear to Exit
Figure 6−68. Menu Configuration − Sticky Levels Page.
Pressing TAKE will cause the sticky level mode to toggle. CLEAR will return to the previous page.
On selection of the Audio soft key in the configuration menu, the following display will appear:
Sticky Outputs · Sticky Levels · Sticky Audio

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
Press TAKE to turn Sticky Audio ON − Clear to Exit
Figure 6−69. Menu Configuration − Sticky Audio Page.
Pressing TAKE will cause the sticky audio mode to toggle. CLEAR will return to the previous page.
On selection of the Prompting soft key in the configuration menu, the following display will appear:
Press TAKE to turn Category Prompting OFF − Clear to Exit
Figure 6−70. Menu Configuration − Category Prompting Page.
Pressing TAKE will cause the category prompting mode to toggle. CLEAR will return to the previous page.
Upon selection of the Password soft key of the menu page, the MENU button will illuminate in red and the following display will be shown:
Panel Security Level = 66 Enter New Password Then Select Take
Figure 6−71. Panel Password Security Page.
If category prompting is enabled, the number pad will illuminate in green. Enter a six−digit password. When six digits have been typed, the TAKE button will illuminate in red to indicate that TAKE should be pressed. If an invalid password is entered and Taken the display will briefly show “INVALID PASSWORD” and clear to accept another number.
The words LOG OUT will be displayed only if the panel is currently set to higher than its defined level. Selecting the soft key under the LOG OUT legend will prompt the user to confirm with the TAKE button:
Panel Security Level = 98 Confirm LOG OUT To
Panel Security Level = 66 By Pressing TAKE
Figure 6−72. Panel Password Security Page − Password typed in.
Completion of a “raise password level” operation, or log out, or selecting the red illuminated MENU button will return the panel to whichever operation mode it was in prior to selection of MENU.
Category Prompting

Control Panel Operation CP 3800
ÎÎÎ
MENU
ÎÎÎ
MENU MODE (CONT’D)
Password Level Request During TAKE
If the user requests a TAKE that requires a higher level password than the panel is currently set to, the user will also be pres- ented with the password security page below. Entry of a valid password and TAKE will execute the take that one time only:
Panel Security Level = 66 Enter New Password Then Select TAKE
Figure 6−73. One Time Only Password Security Page.

Control Panel Operation CP 3800
ÎÎÎ
OVER RIDES
ÎÎÎ
OVERRIDE MODE
This mode is in effect when the “OVERRIDES” button is illuminated.
Up to 10 pages of Overrides (80 total) may be defined. The up/down arrow keys may be used to access all pages containing defined overrides. Overrides may be defined using the file server in the CP Override set assigned to the panel (page 5−96), or, interactively by the user as described below.
Override mode may be selected from either the single or multiple destination home state by pressing the OVERRIDE button, which will then illuminate in green. No keypad operations may be in progress. Any selected levels or audio modes are sus- pended as overrides contain their own level and audio definitions. Selected audio and levels are restored when the user leaves this mode by turning off the OVERRIDE button. The following display will indicate override select mode and show all de- fined override buttons:
1 Destination = PRODCTN4
Figure 6−74. Example Override Selection Mode Menu.
User defined overrides using special audio modes will indicate this with a blinking ‘A’ to the left of the override name.
If no system (file server) or user overrides are defined for the panel, the following message will be displayed:
1 No Overrides Defined, Select OVERRIDE key to define, CLEAR to exit
Figure 6−75.
All defined soft keys will illuminate in red to indicate that they are armed and ready to take an override. Selection of any so illuminated soft key will cause the override to be immediately selected at the previously selected destination(s). No subse- quent TAKE operation is required. In multiple destination mode, the output may be selected before or after pressing the OVERRIDE button.
The top destination line functions in the same manner as defined in the multi destination mode section; it can show up to six destinations; for over 6, the display indicates multiple destinations with ellipses (...).
An override may be applied to a destination that does not match the levels defined for that override. When this situation occurs, the user will be warned with either of the two messages shown on the top line (as appropriate):

Control Panel Operation CP 3800
ÎÎÎ
OVER RIDES
ÎÎÎ
OVERRIDE MODE (CONT’D)
1 Some Override Levels Not Valid For Destination − Partial Take Occurred
Figure 6−76. Example Override Mode Warning Display.
1 All Override Levels Not Valid For Destination − No Take Occurred
Figure 6−77. Example Override Mode Warning Display.
Users may define overrides to any unused accessible location. Overrides defined from the Jupiter file server CANNOT be changed as they do not contain audio modes. User defined overrides do contain audio modes.
Overrides are automatically named by their position. For example, creating an override for the 2nd button of the third page will create an override named “OVERRD18.” User defined overrides may also be erased if no longer needed or to make room for new definitions.
The panel is placed in Define Override mode by selecting a destination and double punching the OVERRIDE button. It will illuminate in red to indicate this mode. The display will indicate this mode and prompt for a button assignment (valid soft key locations will illuminate in green). A blank page will be provided after the last page of overrides.
1 Defining Override − Use Up/Down Buttons And Soft Key To Select Position
Figure 6−78. Example Home Defining Override Menu.
Creating the override definition
When the user has selected an appropriate location, that soft key will illuminate in red and the display will indicate the selec- tion and that it is ready to record the override:
3 Defining Override − Select TAKE to Define − 2ND TAKE to Finish
Figure 6−79. Example Override Definition Menu − Page 3, Fifth Button Position Selected.
When this menu appears the user may deselect the red soft key or select CLEAR to return to the Home Defining Override menu or may deselect the red OVERRIDE button to exit Defining mode.
Entering Define Mode

Control Panel Operation CP 3800
ÎÎÎ
OVER RIDES
ÎÎÎ
OVERRIDE MODE (CONT’D)
To create the definition, the operator selects TAKE. The panel displays it is ready to define an override and the OVERRIDE button blinks in red to indicate that a definition is in progress.
Defining Override − Press TAKE to Complete
Category = Vid_Tape Number = 12 New Source = VTR_0012
Figure 6−80. Example Override Definition Menu − Source Selection.
The user may then execute any kind of basic or complex source selection per normal operation. Destination changes/selec- tions cannot be made as part of the Override definition. All irrelevant keys are ignored during definition; i.e. MENU, PROT/ LOCK, SEQ, DEST. When the selection is completed with the TAKE button, the menu will return to Define Override Mode as shown (OVERRIDE button stops blinking, remains red):
3 Defining Override − Completed − Select TAKE To Confirm Or CLEAR To Cancel
Figure 6−81. Example Override Definition Menu − Page 3, Fifth Button Position Defined.
From this menu the operator can confirm the definition by pressing TAKE or can select CLEAR to return to the Home Defin- ing Override menu to try again. Pressing TAKE will also return the panel to Override Selection mode; an additional press of the OVERRIDE button is required for each completed definition.
Override Definitions may also be aborted at any time by selecting the OVERRIDE button when it is blinking red. A brief message will appear on the top line stating “OVERRIDE DEFINITION ABORTED” and the panel will return to the Override selection menu and the OVERRIDE button will illuminate in green.
The user can view override definitions by placing the panel in the Define Override mode as defined above. The user then selects an existing override. The following display will be shown:
1 Definition of Override
VidTape1 VidTape1 VidTape1 MCart−01 MCart−01 Silence Silence Silence
Figure 6−82. Example Viewing Override Definition.
Page numbers are included if more than eight levels are defined for an override. Special audio modes are indicated with a blinking ‘R’ for Reverse and ‘M’ for Mix. To exit this mode, the user will press either the red OVERRIDE or red CLEAR buttons. This will return the operator to the Define Override Mode.

Control Panel Operation CP 3800
ÎÎÎ
OVER RIDES
ÎÎÎ
OVERRIDE MODE (CONT’D)
Erasing An Override
Overrides may be erased if no longer needed or to make room for new definitions from the Define Overrides Home mode. Enter define mode by double punching the OVERRIDE button (see above for menu display). Selecting CLEAR at this point allows erasing user defined overrides. The display will indicate this mode and prompt for a button assignment (valid soft key locations will illuminate in green):
1 Erasing Override − Use Up/Down Buttons And Soft Key To Select Position
Figure 6−83. Example Erasing Override Menu.
The user may scroll pages as appropriate and select the desired button position to be erased. Upon selection of a valid position the user will be prompted for confirmation while the selected override name blinks.
1 Erasing Override − Select TAKE To Confirm Or CLEAR To Cancel
Figure 6−84. Example Erasing Override Menu − Seventh Button Position Clear Confirmation.
From this menu the operator can confirm the desired clear operation by pressing TAKE or can select CLEAR to return to the Home Defining Override menu to try again. Pressing TAKE will also return the panel to Override Selection mode; additional presses of the OVERRIDE and CLEAR buttons are required for each completed clear.
As with Override Definitions, clears may also be aborted at any time by selecting the OVERRIDE button when it is red or blinking red. A brief message will appear on the top line stating “OVERRIDE CLEAR ABORTED” and the panel will return to the Override selection menu and the OVERRIDE button will illuminate in green.

Control Panel Operation CP 3800
ÎÎÎ
SEQ
ÎÎÎ
SEQUENCE MODE
This mode is in effect when the “SEQ” button is illuminated.
Sequence mode may be selected from either single or multiple destination home state by selecting the SEQ button, which will then illuminate in green. No keypad operations may be in progress. Any selected levels or audio modes are suspended while in sequence mode as sequences contain their own level and audio definitions. Selected audio and levels are restored when the user leaves this mode by turning off the SEQ button. The following display will indicate sequence select mode and show all defined sequence buttons:
1 Select Sequence to Execute − CLEAR to Cancel
Figure 6−85. Example Sequence Selection Mode Menu.
User defined sequences using special audio modes will indicate this with a blinking ‘A’ to the left of the sequence name.
If no system (file server) or user sequences are defined for the panel, the following message will be displayed:
1 No Sequences Defined, Select SEQ key to define, CLEAR to exit
Figure 6−86.
All defined soft keys will illuminate in red to indicate that they are armed and ready to take a sequence. Selection of any so illuminated soft key will cause the sequence to be immediately executed to the defined destinations. No subsequent TAKE operation is required.
Up to 10 pages of Sequences (80 total) may be defined. The up/down arrow keys may be used to access all pages containing defined sequences. Sequences may be defined in the sequence set for the panel or interactively by the user as described below.
Users may define sequences to any unused accessible location.
One additional page will be available when defining sequences. Sequences are automatically named by their position. For example, creating an sequence for the 2nd button of the third page will create an sequence named “USRSEQ18.” User defined sequences may also be erased if no longer needed or to make room for new definitions.

Control Panel Operation CP 3800
ÎÎÎ
SEQ
ÎÎÎ
SEQUENCE MODE (CONT’D)
The panel is placed in Define Sequence mode by double punching the SEQUENCE button, which will then illuminate in red to indicate this mode. The display will indicate this mode and prompt for a button assignment (valid soft key locations will illuminate in green):
1 Defining Sequence − Use Up/Down Buttons and Soft Key to Select Position
Figure 6−87. Example Home Defining Sequence Menu.
Creating the Sequence Definition
When the user has selected an appropriate location, that soft key will illuminate in red and the display will indicate the selec- tion and that it is ready to record the sequence:
3 Defining Sequence − Select TAKE to Define − Press SEQ to Finish
Figure 6−88. Example Sequence Definition Menu − Page 3, Fifth Button Position Selected.
When this menu appears the user may deselect the red soft key or select CLEAR to return to the Home Defining Sequence menu or may deselect the red SEQUENCE button to exit Defining mode.
To create the definition, the operator selects TAKE. The panel returns to single or multiple destination home mode (wherever it was) and the Sequence button blinks in red to indicate that a definition is in progress.
In multiple destination mode the user is then prompted to select a sequence output and a source:
3 Select Sequence Outputs, Then Select Source
Figure 6−89.
Entering Define Mode

Control Panel Operation CP 3800
ÎÎÎ
SEQ
ÎÎÎ
SEQUENCE MODE (CONT’D)
In single destination mode the user is prompted to select a source:
3 Destination = Studio A, Select Source
Figure 6−90.
The user may then set up any kind of basic or complex source selection per normal operation. Destination changes/selections are also recorded as part of the Sequence definition. Audio mode selections are relevant to the specific switch being defined. All irrelevant keys are ignored during definition; i.e. MENU, PROT/LOCK, OVERRIDE. When the operator has completed all desired switches, the blinking SEQ button is selected to complete the definition; the menu will return to Define Sequence Mode as shown (SEQ button stops blinking, remains red):
3 Defining Sequence − Completed − Select TAKE To Confirm Or CLEAR To Cancel
Figure 6−91. Example Sequence Definition Menu − Page 3, Fifth Button Position Defined.
From this menu the definition can be confirmed by pressing TAKE, or CLEAR can be selected to return to the Home Defining Sequence menu to try again. Pressing TAKE will also return the panel to Sequence Selection mode, an additional press of the SEQ button is required for each completed definition.
Sequence Definitions may also be aborted at any time by selecting the SEQ button when it is blinking red. A brief message will appear on the top line stating “SEQUENCE DEFINITION ABORTED” and the panel will return to the Sequence selec- tion menu and the SEQ button will illuminate in green.
If the user enters too many switches and fills the sequence, the following prompt will appear:
1 Sequence Full. Press TAKE to Finish or CLEAR to Cancel
Figure 6−92. Example Sequence Definition Menu − Too many entries.
Pressing the TAKE button completes the sequence at the current switch. Pressing CLEAR cancels the sequence entry.

Control Panel Operation CP 3800
ÎÎÎ
SEQ
ÎÎÎ
SEQUENCE MODE (CONT’D)
Viewing Sequence Definitions
To view sequence definitions, place the panel in the Define Sequence mode as defined above. Then select an existing se- quence. The following display will be shown:
1 Definition of , Entry:01, Destination=PROCTN1, Source=Test−17
Figure 6−93. Example Viewing Sequence Definition − Sequence Entry 1.
Page numbers are included if more than eight levels are defined for a sequence. Special audio modes are indicated with a blinking ‘R’ for Reverse and ‘M’ for Mix. If more than one entry exists, the TAKE button will turn red, allowing the user to display the next entry. To exit this mode, the user will press either the red SEQUENCE or CLEAR buttons. This will return the operator to the Define Sequence Mode. The CLEAR button turns red when the last sequence entry is reached.
Sequences may be erased if no longer needed or to make room for new definitions from the Define Sequences Home mode. Enter define mode by pressing the SEQ button (see above for menu display). Selecting CLEAR at this point allows erasing user defined sequences. The display will indicate this mode and prompt for a button assignment (valid soft key locations will illuminate in green):
1 Erasing Sequence − Use Up/Down Buttons And Soft Key To Select Position
Figure 6−94. Example Erasing Sequence Menu.
The user may scroll pages as appropriate and select the desired button position to be erased. Upon selection of a valid position the user will be prompted for confirmation while the selected sequence name blinks on the display.
1 Erasing Sequence − Select TAKE To Confirm Or CLEAR To Cancel
Figure 6−95. Example Erasing Sequence Menu − Seventh Button Position Clear Confirmation.
From this menu the operator can confirm the desired clear operation by pressing TAKE or select CLEAR to return to the Home Defining Sequence menu to try again. Pressing TAKE will also return the panel to Sequence Selection mode; an additional press of the SEQ and CLEAR buttons are required for each completed clear.
As with Sequence Definitions, clears may also be aborted at any time by selecting the SEQ button when it is red or blinking red. A brief message will appear on the top line stating “SEQUENCE CLEAR ABORTED” and the panel will return to the Sequence selection menu and the SEQ button will illuminate in green.

Control Panel Operation CP 3800
ÎÎÎ
PROT/
LOCK
ÎÎÎ
PROTECT/LOCK MODE
The bottom two buttons below the Mode group select protection or locking (PROT/LOCK) and clear category/number selec- tions and/or cancel ongoing definitions (CLEAR).
Protection is accessed by selecting the PROT/LOCK button once, illuminating green to indicate this condition. Locking is accessed by selection twice (double punch). The PROT/LOCK button will illuminate red. If the panel is in single destination mode, protection/locking is applied to the current destination. If in multiple destination mode, the user may select a destina- tion(s) beforehand or afterwards from the soft keys; the lamp in the PROT/LOCK button will blink if a destination is still needed. A third press will cancel the mode. Protect/Lock status will also be shown on the destination status display in the 1st character position with a blinking “P” or “L” as appropriate. As soon as a valid destination and Protect/Lock mode is selected, the TAKE button will illuminate in red. Protect/Lock functions take effect upon selection of the TAKE button and may be incorporated into more complex takes as described below.
If the panel’s password level is 90 or above, the unlock or unprotect operation will be “Force Unlock.” The control panel will override locks or protects from other panels. If the PROT/LOCK operation cannot be completed, an error message will be displayed, including the name of the panel that locked or protected the output, if applicable. Switches that cannot be completed due to locks and protects will also display an appropriate error message.
Locking or protecting a single destination in either multiple destination or single destination mode will result in the prompts below. In multiple destination mode, the bottom line will display the current page of destination names and the selected des- tination buttons will be illuminated. In single destination mode, the bottom line will display the status of the output.
1 LOCK Destination PRDCTN4 ? Select TAKE to Execute, CLEAR to Cancel
Figure 6−96. Example Lock Single Destination Prompt.
1 PROTECT Destination PRDCTN4 ? Select TAKE to Execute, CLEAR to Cancel
Figure 6−97. Example Protect Single Destination Prompt.
Locking or protecting multiple destinations will result in the following prompts:
1 LOCK Destinations? Select TAKE to Execute, CLEAR to Cancel
Figure 6−98. Example Lock Multiple Destinations Prompt.

Control Panel Operation CP 3800
ÎÎÎ
PROT/
LOCK
ÎÎÎ
PROTECT/LOCK MODE, CONT’D
1 PROTECT Destinations? Select TAKE to Execute, CLEAR to Cancel
Figure 6−99. Example Protect Multiple Destinations Prompt.
The bottom line will display the current page of destination names and the selected destination buttons will be illuminated.
If the output is already locked or protected, the displays will have an “un” added to the messages for unlock and unprotect. Pressing the TAKE button will unlock or unprotect the output.
For additional protect/lock information − see page 6−12.

Control Panel Operation CP 3800
All destinations employing tie lines will be so indicated with a blinking “T” in the destination status display in the 1st character position. When in single destination mode, the 1st character position of each level will also reflect tie line status with the blink- ing “T.”
Any time a Take is attempted that requires a tie line connection but none are available, the following display will appear show- ing the name of the destination, its current source, and the attempted source:
1 NO TIE LINES LEFT TO SWITCH PRODCTN4 to OuterSpc
Figure 6−100. Example Tie Lines Used Up Warning Message − Multi Destination Mode.
This display will remain for an undetermined timeout or until the CLEAR button is selected, which ever comes first. If the take is to multiple destinations via multiple destination mode or a sequence, as much of the operation requested as is possible will be performed. If multiple tie line requests were not fulfilled, multiple warnings will stack up and be displayed consecu- tively.
As required, this tie line warning will appear during normal takes, overrides and sequences. When this condition occurs, all levels of switching for the particular take will occur for those levels which can (those that do not require tie lines or still have tie lines available). Sequences will execute all other takes that can be completed.
For an explanation of CP 3800A series error messages (such as “10xx” or “3200” or “80xx”) please refer to Appendix R.

Control Panel Operation CP 3808
VTR−01−V
1 VTR CAM SAT
EJ
COLORBAR
VCR NET REM
VTR−01−L
FILM
PRESET
VTR−01−R
FS
TEST PTCH CGEN
VTR−01−T
Figure 6−101.
(For installation and configuration instructions, please see page 2−45.)
The CP 3808 control panel is a 16−category,* full−matrix,* multi level breakaway* panel capable of locking* and protecting* outputs. The panel features eight−character display capability and relegendable, lighted push buttons. The panel includes four dedicated level* display windows and breakaway buttons.
All push buttons are capable of both green and red back lighting, with green generally used to show a selected function and red to indicate an operational mode in progress.
As an option, the CP 3808 can be operated in connection with an adjacent CP 3809 Expansion Panel (see page 6−124) or a CP 3810 Expansion Panel (see page 6−126).
The panel has two basic modes of operation: Home mode, and Source Entry mode.
In Home mode, the level displays (the four displays on the left side of the panel) indicate status* of the first four levels of the switcher (i.e., the first four levels listed on the CP Level set table assigned to this panel). To provide “flip−flop” switching, the Preset window shows the previously selected source switched to the panel’s controlled output.
Whenever the operator starts to enter a new source on the category/number keypad, the Preset window switches to a prompt- ing mode. The level displays show the names of the first four levels; the four level buttons can now be used for breakaway switching.
Detailed operating instructions follow.
* Defined in Glossary Section

Control Panel Operation CP 3808
CP 3808
VTR−01−V
1 VTR CAM SAT
EJ
VCR NET REM
VTR−01−L
STUDIO−A
FILM
PRESET
VTR−01−R
FS
VTR−01−T
TEST PTCH CGEN
Figure 6−102.
Press once to show current destination in Preset window.
To select a destination:
The Preset window will display the present destination.
— pressing a category (e.g., “VTR”) and unit number combination, or by
— using the UP and DOWN arrows to scroll through all available destinations, or by
— pressing a category key and using UP/DOWN to scroll through the available units in that category; or by
— selecting a destination on the CP 3809 Expansion Panel (if so equipped—see Figure 6−104).
If the output has been locked* by another panel, the TAKE button will blink red. To continue, the output must be un- locked (by the panel used to set the lock).
For additional protect/lock information − see page 6−12.
To verify the new output, press MENU again. To return to Home mode, press CLEAR.

Control Panel Operation CP 3808
CP 3808
Video
1 VTR CAM SAT
EJ
VCR NET REM
Left
VTR−01
FILM
PRESET
Right
FS
TEST PTCH CGEN
T/C
Figure 6−103.
To select a source (input):
— press a category (e.g., “VTR”) and unit number combination, or
— use the UP and DOWN arrows to scroll through all sources, or
— press a category key and use UP/DOWN to scroll through the possible units in that category...
...then press TAKE.
On a valid entry, the defined eight character mnemonic will be displayed in the Preset window and all applicable level lamps will light in green. The level displays (the four left windows) will show the status for each of the first four levels defined in the CP Level set assigned to the panel.
If entry of a password is requested, please see Passwords on page 6−75.
1 VTR CAM SAT
EJ
VCR NET REM
FILM
1 STU
2 STU
3 STU
4 STU
FS
TEST PTCH CGEN
8 STU 7 STU 6 STU 5 STU
Figure 6−104. CP 3808 with CP 3809 Expansion Panel.
Before pressing TAKE, use the expansion panel to select the destination(s). The selected output button will illuminate in “high” green to show it will be affected by the switch. These buttons can be toggled on/off before pressing TAKE.
(To assign Expansion Panel buttons to outputs, see pages 5−79 and 6−124 (CP 3809) or 5−79 and 6−126 (CP 3810).

Control Panel Operation CP 3808
CP 3808
Video
1 VTR CAM SAT
EJ
VTR−041
VCR NET REM
Left
FILM
PRESET
Right
FS
T/C
TEST PTCH CGEN
Figure 6−105.
Breakaways can be accomplished either by selecting the levels to switch, and then selecting a source; or by selecting a source and then deselecting unwanted levels.
Breakaways can be disabled on the CP Level Set table by setting the Break Flag for each level to ‘N.’ (See page 5−58.)
The level mnemonic appears in the level window and the button will illuminate in “high” green. (To adjust button bright- ness, see page 6−71.) The level may be toggled off by selecting it again. To move beyond the first four levels, use the UP and DOWN arrow keys.
Pressing CLEAR will cancel the operation.
The source will switch only on the preset levels, while the non−selected levels will remain at the previously selected source.
The level windows will indicate status of the first four levels of the switcher; the Preset window will return to the pre- viously selected source. This permits flip−flop switching.

Control Panel Operation CP 3808
The available level mnemonics appear in the Level windows; applicable level buttons will illuminate in “high” green.
The button lamp will change to “low” green, and the corresponding level window will be blanked. To move beyond the first four levels, use the UP and DOWN arrow keys. Pressing CLEAR will cancel the operation.
The selected levels will switch to the new source. The deselected levels will remain at the previously selected source.
The level displays will indicate status of the first four levels of the switcher; the Preset window will return to the pre- viously selected source. This permits flip−flop switching.
The CP 3808 will allow operators to perform complex split switches using multiple sources on levels not defined for all sources, similar to a salvo switch to a single destination. For example, assume the user has defined Camera−1 with Video and TimeCode only levels. However, he or she desires CD−1 for audio. To perform this switch in one take:
In this example, the operator would press the buttons corresponding to Video, Left, Right, and TimeCode. The buttons will light in “high” green, indicating they are selected.
In this example, Camera−1 would be selected.
In this example, Left and Right.
In this example, CD−1 This source will automatically be assigned to the remaining levels, Left and Right audio.
Destination Mode — Press MENU Once
In this mode (already described on page 6−65) the destination is shown in the Preset window. If the panel is equipped with a CP 3809 Expansion, the outputs controlled by that panel will be indicated.

Control Panel Operation CP 3808
To return to Home mode, press CLEAR.
This mode allows the UP and DOWN buttons to select and status levels beyond the first four. The mode is indicated by the message “1 STATUS” in the Preset window. The “1” refers to “page 1,” that is, the first page of four levels being displayed.
To return to Home mode (in which UP and DOWN are used for source selection) press CLEAR.
This mode is accessed by pressing MENU three times; the MENU button will light in red and the Preset window will display the message “1 AUDIO.” The level windows show the audio mode for each audio channel. In Figure 6−106, both audio chan- nels are set to “Normal.”
1 VTR CAM SAT
EJ
1 AUDIO
VCR NET REM
NORMAL
FILM
PRESET
NORMAL
FS
TEST PTCH CGEN
Figure 6−106.
Other possibilities are:
MIX − Left and right channels are mixed on this channel.
REVERSE − Signal is from opposite channel.
To move beyond the first four levels, use the UP and DOWN arrow keys.
Locking an output prevents that output from being switched by any panel in the system, including the initiating panel.
To lock an output:

Control Panel Operation CP 3808
This has the effect of locking only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The TAKE button will illuminate steady red, indicating the output has been locked by this panel.
If another panel selects this output for control, that panel’s LOCK button will blink. If the other panel attempts to switch this output, a “LOCKED” message will appear, along with the name of the locking panel.
If the other panel has no LOCK button, that panel’s TAKE button will blink.
To unlock the output:
The TAKE button lamp will return to green.
If the output will not unlock, it has been locked by another panel. The display will indicate “Locked” and show the name of locking panel.
An output may be forced unlocked, no matter which panel locked it, if the password level of the unlocking panel is level 90 or greater. The password level is defined in the MPK Devices table entry (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
Protecting an output prevents that output from being switched by other panels in the system. The protecting panel may still change the outputs.
To protect an output:
This has the effect of protecting only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The TAKE button will flash green, indicating the output has been protected by this panel.
If another panel selects this output for control, that panel’s PROT button will blink. If the other panel attempts to switch this output, a “PROTECT” message will appear, along with the name of the protecting panel.
If the other panel has no LOCK button, that panel’s TAKE button will blink.

Control Panel Operation CP 3808
To unprotect the output:
The TAKE button will return to green.
If the output cannot be unprotected, it has been protected by another panel. The display will indicate “Protect” and show the name of protecting panel.
An output may be force unprotected, no matter which panel protected it, if the password level of the unprotecting panel is level 90 or greater. The password level is defined on the MPK Device table (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unprotect the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
This option displays the current MPK address for this panel.
To exit the diagnostics mode press CLEAR at any time. (It may be necessary to press CLEAR twice.)
This test cycles through the button lamps (LEDs) and illuminates them in green and then red. The test will stop after one cycle. Pressing CLEAR during this test will cancel this test and return the panel to the beginning of the current diagnostic. Pressing CLEAR again will return the panel to the Home mode.
Info displays the panel’s Application (PROM) version, Xilinx FPGA* version. Variant version (not implemented), and PCB (hardware) version. Press CLEAR to exit.
LED Test · Info

Control Panel Operation CP 3808
When selected, this option displays the current baud rate for the panel. Press DOWN to decrease the baud rate, UP to increase. Available baud rates are: 38400, 19200, 9600, 4800, 2400, and 1200. Pressing TAKE will program the changed setting; CLEAR will cancel.
The baud rate must agree with the setting for the CM 4000 port used by the panel (see Serial Protocol on page 5−30).
When selected, this option displays the current MPK address for this panel and permits entry of a new address. Since the ad- dress is hexadecimal, the numeric key pad is used for numbers 0 through 9; on the CP 3808 the six remaining category keys are used for numbers A through F (see Figure 6−107).
Panel ID
B
0057A32E
E F
D
Figure 6−107. Buttons used for hex address entry.
On the CP 3830, the six level keys are used for numbers A through F.
On the CP 3809, the top window shows the current address and the bottom window shows the new address as it is entered. Starting with the first digit of the new address, use the UP and DOWN buttons to change the value, press TAKE, change the next value, etc.
Pressing TAKE will program the newly entered address; CLEAR will cancel.
The address must agree with the setting for the panel on the MPK Devices table (see page 5−107).
This diagnostic requires the panel be disconnected from the MPK data cable.
This test allows the factory to test the MPK connection on the control panel.
This option allows the user to change the “low” and “medium” levels of green button illumination, the “low” and “medium” levels of red button illumination, and the level of LED (display character) illumination. The “high” button levels are not ad- justable.
* Defined in Glossary section

Control Panel Operation CP 3808
The “low” green level is used for normal button lighting. “High” green and “high” red are also used, but these are not adjust- able.
For each setting, use the UP and DOWN buttons to change to the desired brightness and press TAKE. Press CLEAR to exit.
This test rotates through the button lamp and Display tests continually. Press CLEAR to cancel.
This diagnostic displays the number of each button as it is pressed. Pressing the CHOP key will change the lamp color. Press- ing CLEAR twice exits.
This test cycles through and displays all legal characters. The test will stop after one cycle. Pressing CLEAR exits. (On the CP 3809, press the lower right button to exit.)
Burn In · Key test · Display test

Control Panel Operation CP 3808
The CP 3808 has the capability of controlling Venus Audio Modes, which are Normal, Mix, and Reverse. These changes are made to individual levels prior to completing a switch by pressing the TAKE button.
To perform a special stereo switch:
The MENU button will light in red and the Preset window will display the message “1 AUDIO.” The level windows show the audio mode for each audio channel. In Figure 6−108, both audio channels are set to “Normal.”
1 VTR CAM SAT
EJ
1 AUDIO
VCR NET REM
NORMAL
FILM
PRESET
NORMAL
FS
TEST PTCH CGEN
Figure 6−108.
NORMAL − Use left audio for this channel
LEFT LEFT (Left signal on Left channel)
MIX − Mix left and right on this channel
LEFT (Left + Right signals on Left channel)
REVERSE − Cross opposite channel signal over to this channel
LEFT (Right signal on Left channel)

Control Panel Operation CP 3808
NORMAL − Use right audio for this channel
RIGHT RIGHT (Right signal on Right channel)
MIX − Mix left and right on this channel
RIGHT RIGHT (Left + Right signals on Right channel)
REVERSE − Cross opposite channel signal over to this channel
RIGHT (Left signal on Right channel)
If entry of a password (“PASS = ”) is requested, the output about to be affected has a password level higher than that of the panel. (Some panels may display their password level as entered on the MPK Devices table, e.g., “PASS = 48”.)
After entry of an appropriate−level six−digit password, the command can be completed by pressing TAKE; however, the panel will then revert to its previous password level.
See page 6−126.

Control Panel Operation CP 3824
(For installation and configuration instructions, please see page 2−46.)
The CP 3824 control panel is a locally−programmable, full−matrix,* multiple level breakaway panel capable of locking* and protecting* outputs. The panel features eight−character display capability and relegendable, lighted push buttons. The 24 but- ton−per−source keys on the left side of the panel are initially assigned to inputs from the file server but some or all can be re−assigned to new inputs at any time using only the panel itself. Sources can also be selected by scrolling up/down an LED display of “Preset” mnemonics or by using the Category/Number keypad. The Current display window shows the source switched to the panel’s controlled output. The Preset window shows the new source as it is being entered from the category and keypad push buttons; after TAKE is pressed, the previous source is shown in the Preset window. This allows “flip−flop- ping” the sources, or switching between the current and preset sources by simply pressing the TAKE button (see page 6−78).
Press once, then select new output
1 VTR
2 CG
3 NET
4 VCR
5 CAM
PAGE
PROT
MENU
1 2 3 4
5 6 7 8
9 8 REM 7 SS 6 AUX
0 PTCH 1 FILM
LEVEL
LOCK CHOP
VTR
1 VTR
2 VTR
3 VTR
STU
1 STU
2 EDIT
1 EDIT
EBS
1 EBS
2 TEST
1 TEST
PRE−
CLEAR
STU TEST SAT FS MISC
SET TAKE
SEND
PRESET
Figure 6−109.
To select a destination:
The Preset window will display the present destination.
— pressing a category (e.g., “VTR”) and unit number combination, or by
— using the UP and DOWN arrows to scroll through all destinations, or by
— pressing a category key and using UP/DOWN to scroll through the available units in that category.
The Current window will return to the input mnemonic; the Preset window will go blank.
* Defined in Glossary Section
Category/Number keys

Control Panel Operation CP 3824
1 VTR
2 CG
3 NET
4 VCR
5 CAM
PAGE
PROT
MENU
1 2 3 4
5 6 7 8
CURRENT
9 8 REM 7 SS 6 AUX
0 PTCH 1 FILM
LEVEL
LOCK CHOP
VTR
1 VTR
2 VTR
3 VTR
STU
1 STU
2 EDIT
1 EDIT
EBS
1 EBS
2 TEST
1 TEST
CLEAR
STU TEST SAT FS MISC
PRE−
SET TAKE
SEND
PRESET
Button−per−source keys (programmable overrides) Category/ Number keys
Figure 6−110.
To select an input:
— press one of the 24 button−per−source (Override) keys on the left side of the panel, or
— press a category (e.g., “VTR”) and unit number combination, then press TAKE, or
— use the UP and DOWN arrows to scroll through all sources, then press TAKE, or
— press a category key and use UP/DOWN to scroll through the possible category entries, then press TAKE.
On a valid entry, the defined eight character mnemonic will be displayed in the Preset window.
When using the UP/DOWN arrows, scrolling past the end of the list will wrap around to the other end.
The newly selected source will be shown in the Current window. If an Override button was used to select the source (or if an Override button corresponds to the selected source) the button will illuminate “high” green. However, the button will not illuminate if the first level assigned to the panel on the Override set table has been set to “No” switching. Nor will it illuminate unless all levels assigned to the button are switched.
If entry of a password is requested, please see Passwords on page 6−75.
With PRESET on, you can select an Override key(s) and check the source name(s) before pressing TAKE. The name of the selected input will be previewed in the Preset window.
Although the CP 3824 has only 24 Override keys, up to 360 inputs can be assigned, i.e., 15 groups (“pages”) of 24 inputs each. To scroll to other pages, press PAGE, then UP or DOWN, TAKE. Pressing both UP and DOWN simultaneously will reset to page 1.
The Override keys can be programmed using the panel itself (see page 6−85) or from the file server (see page 5−96).

Control Panel Operation CP 3824
The present source is shown in the Current window, while the previous source is shown in the Preset window. This allows “flip−flopping” the sources, or switching between the current and preset sources by simply pressing the TAKE button.
As an example, if you wish to change the source from BARS to VTR−002, first select the VTR category. The Preset display updates as follows, prompting with the first unit in the VTR category:
Figure 6−111. VTR−001
PRESET
The user will then press the 2" key. The Preset display will update:
Figure 6−112. VTR−002
PRESET
To complete the selection, press the red TAKE button to switch source VTR−002 to the panel’s defined output. The Preset window and the Current window will be swapped as shown, indicating that the previous source can be rese- lected.
COLORBAR
Figure 6−113.

Control Panel Operation CP 3824
Locking an output prevents that output from being switched by any panel in the system, including the initiating panel.
To lock an output:
This has the effect of locking only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will blink, indicating the output has been locked by this panel.
If another panel selects this output for control, that panel’s LOCK button will blink. If the other panel attempts to switch this output, a “LOCKED” message will appear, along with the name of the locking panel.
If the other panel has no LOCK button, that panel’s TAKE button will blink.
To unlock the output:
The LOCK button lamp will stop blinking.
If the output will not unlock, it has been locked by another panel. The display will indicate “Locked” and show the name of locking panel.
An output may be forced unlocked, no matter which panel locked it, if the password level of the unlocking panel is level 90 or greater. The password level is defined in the MPK Devices table entry (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
Protecting an output prevents that output from being switched by other panels in the system. The protecting panel may still change the outputs.
To protect an output:
This has the effect of protecting only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will blink, indicating the output has been protected by this panel.
If another panel selects this output for control, that panel’s PROT button will blink. If the other panel attempts to switch this output, a “PROTECT” message will appear, along with the name of the protecting panel.

Control Panel Operation CP 3824
If the other panel has no LOCK button, that panel’s TAKE button will blink.
To unprotect the output:
The PROT button will stop blinking.
If the output cannot be unprotected, it has been protected by another panel. The display will indicate “Protect” and show the name of protecting panel.
An output may be force unprotected, no matter which panel protected it, if the password level of the unprotecting panel is level 90 or greater. The password level is defined on the MPK Device table (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unprotect the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
To chop* an output, you must use the Category/number keypad. Select the first source and press TAKE. Then select the second source and press CHOP. The CHOP button will blink, with the message “IN CHOP” displayed in the Current window.
The chop operation will automatically stop after approximately two minutes. The chop will finish with the source in the Preset window being switched to the destination. The chop may be manually terminated by performing another source selection and pressing TAKE.
For additional chop information − see page 6−13.

Control Panel Operation CP 3824
Breakaway Using Override Keys (PRESET Off)
PAGE
PROT
MENU
CURRENT
LEVEL
LOCK CHOP
CLEAR
PRE−
SET TAKE
SEND
PRESET
These six buttons now function as temporary level select keys. Lighted buttons initially indicate defined levels.
CURRENT
VIDEO
PRESET
Name of selected Level shown here
Toggle OFF levels you do not wish to switch. In this example, Level 1 is toggled OFF. Only LEFT and RIGHT will switch.
1 2 3 4
5 6 7 8
VTR 002
CURRENT
VTR
1 VTR
2 VTR
3 VTR
STU
1 STU
2 EDIT
1 EDIT
EBS
1 EBS
2 TEST
1 TEST
VTR−002
PRESET
Figure 6−114.
Select desired Override input. This completes the switch. 4
To check the switch, press LEVEL. Then press one of the six temporary level keys; status will be shown in the Current window. Then press CLEAR.
If there are more than six levels, use the UP/DOWN keys to access the second set of six levels, etc.
1 Press CLEAR · Press LEVEL · Status shown here

Control Panel Operation CP 3824
1 VTR
2 CG
3 NET
4 VCR
5 CAM
CURRENT
9 8 REM 7 SS 6 AUX
0 PTCH 1 FILM
CLEAR
STU TEST SAT FS MISC
PRESET
2 Select a Category and Number§
§ Steps 2 and 3 can be performed
in reverse order if desired.
PAGE
MENU PROT
CURRENT
LEVEL
LOCK CHOP
SEND VTR−002
PRE−
PRESET
SET TAKE
These six buttons now function as temporary level select keys. Lighted buttons initially indicate defined lev- els.
CURRENT
VIDEO
PRESET
Name of selected Level shown here
Toggle OFF levels you do not wish to switch. In this example, Level 1 is toggled OFF. Only LEFT and RIGHT will switch.
VIDEO
TAKE
PRESET
Press TAKE. 5
To check the switch, press LEVEL. Then press one of the six temporary level keys; status will be shown in the Current window. Then press CLEAR.
If there are more than six levels, use the UP/DOWN keys to access the second set of six levels, etc.
Figure 6−115.
1 Press CLEAR · Press LEVEL§ · Preset shown here

Control Panel Operation CP 3824
This function allows setup of different sources on different levels with all levels switched using a single TAKE. For example, you can select video from VTR1 and audio from VTR2 to switch to VTR3 with a single TAKE.
The Override keys cannot be used for this function.
This activates the six “temporary level” buttons (the outlined buttons in Figure 6−116). Lighted buttons initially indicate defined levels.
PRESET
Figure 6−116.
This will automatically select the levels not selected for the first source.
There are two ways to check status on more than one level:
— Press LEVEL, then press one of the six “temporary level” keys. The name of the selected level will appear in
the Preset window; the status of the selected level with be shown in the Current window.
— Press PRESET, then press LEVEL repeatedly to step through the levels. The name of the selected level will
appear in the Preset window; the status of the selected level will be shown in the Current window. You can also use UP/DOWN to step through the levels.
This function allows breakaway operation during which the selected Levels remain selected after a TAKE. For example, you may want to keep switching different video test signals to a destination but not switch audio tone. To turn on sticky mode:
Temporary Level buttons

Control Panel Operation CP 3824
The word “STICKY” appears in the Current window.
If more than six levels have been defined, UP/DOWN will increment through additional pages of levels. When multiple pages of levels exist, the Preset display will prompt PG 1 (2, 3, etc.) next to the “ON,” and allow the user to select addi- tional pages for toggling on or off the level.
This activates the six “temporary level” buttons (the outlined buttons in Figure 6−117). Lighted buttons initially indicate defined levels.
These six buttons function as temporary level select keys in Sticky mode.
Figure 6−117.
CURRENT
LEFT
PRESET
Sticky mode is now active, as indicated by the blinking LEVEL button.
To make a switch when sticky levels are in effect, select the desired input. Only the sticky levels will switch.
To find out which levels are sticky, press MENU three times; then press TAKE. The appropriate temporary level keys will illuminate.
To cancel sticky levels, press MENU three times, then use UP/DOWN to toggle the display to “STICKY NOW OFF.” Then press CLEAR or TAKE.

Control Panel Operation CP 3824
The 24 Override keys on left side of the panel can be programmed from the front panel using the SEND key.
This returns the panel to the “home state.”
a. Press PAGE, then UP/DOWN to access additional pages.
The page number is shown in the Current window. Pressing UP and DOWN together returns to page 1.
The number of possible pages and positions depends on the CP Override set that has been assigned to this panel. For example, if the CP Override set contains 25 entries, then one page of 24 buttons has been defined, and there is one button defined for page 2. In this case, 2 pages of 24 positions each are available for definition from the front panel.
b. Press TAKE.
This locks the panel to the selected page number.
c. Press PRESET.
d. Press the Override key you would like to use. Check the Preset window for the current assignment.
e. Repeat Steps a. through d. until you find a suitable location.
The name of the new input is shown in the Preset window.
The display will read “SEND TO BUTTON.”
The input is now assigned to the button.

Control Panel Operation CP 3824
Preset sources assigned to the 24 programmable buttons and their various pages are initially assigned in the Jupiter Configura- tion Sets and downloaded to the CM 4000. These initial assignments are considered the “DEFAULT” assignments. Other preset sources and combinations of levels can be assigned dynamically at the CP 3824 without downloading new configura- tion sets.
To restore any or all of the “DEFAULT” source assignments:
The panel displays “DEFAULT SELECT?”
The 15 category/number buttons are now used as “temporary page” keys. Each illuminated category/number button rep- resents a page of 24 inputs. For example, if 25 inputs have been defined, then the first two buttons will illuminate. See Figure 6−118.
These 15 buttons function as temporary page select keys in Restore Override mode.
Figure 6−118.
3 2 1 4 5
7 8 9 10
15 14 13 12 11
The SELECT CHOICE − With “SELECT” displayed in the lower display, pages with the original default assignments still in effect are illuminated. Pages with reprogrammed buttons can be selected as desired (toggled on). Pressing TAKE restores the selected pages to the default settings. The word DONE appears in the lower display after TAKE is pressed.
The ALL CHOICE − With “ALL” displayed in the lower display, all the temporary page buttons with defined inputs illuminate. Pressing TAKE returns all the programmable buttons on all pages of 24 buttons to their “DEFAULT” source assignments. The word “DONE” appears in the lower display after TAKE is pressed.

Control Panel Operation CP 3824
Destination Mode — Press MENU Once
In this mode (already described on page 6−76) the destination is shown in the Preset window.
To return to Home mode, press CLEAR.
This mode is used to return Override buttons to the inputs assigned by the file server. See page 6−86.
Allows breakaway operation during which the selected Levels remain selected after a TAKE. See page 6−83.
Panel ID (Address) Mode — Press MENU Five Times
This option displays the current MPK address for this panel in the Preset window.
For a description of the diagnostics and adjustments, please see the CP 3808 Diagnostic Mode on page 6−71, starting with Step 2. Except as noted, this description applies to the CP 3824.

Control Panel Operation CP 3830
1 VTR CG NET
COLORBAR
VCR CAM SAT
CURRENT
FILM PATCH STU
PRESET
TEST NUM AUX
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−119.
(For installation and configuration instructions, please see page 2−47.)
The CP 3830 Control Panel is a 12−category,* full−matrix,* multi−level* breakaway* panel, capable of locking,* protect- ing,* and chopping* outputs. The panel features eight−character display capability and relegendable, lighted push buttons.
The Current display window shows the source switched to the panel’s controlled output. The Preset window shows the new source as it is being entered from the category and keypad push buttons; after TAKE is pressed, the previous source is shown in the Preset window. This allows “flip−flopping” the sources, or switching between the current and preset sources by simply pressing the TAKE button (see page 6−78).
The push buttons are capable of green, red, and amber back lighting, with green generally used to show a selected function and red to indicate an operational mode in progress. The amber color is presently used only for a CP 3830 dedicated output panel (see page 5−126).
As an option, the CP 3830 can be operated in connection with an adjacent CP 3809 Expansion Panel (see page 6−124) or a CP 3810 Expansion Panel (see page 6−126).
Dual CP 3830 panels can be configured so that one of the panels is used as a dedicated output panel (see page 5−126). Dual output mode is also possible with two panels side by side.
The CP 3830 can also be configured to control two outputs, with the second output used for preview. In this mode, the panel is referred to as a “CP 3830P.” Note: The CP 3830P cannot be operated with an expansion panel.
* Defined in Glossary Section

Control Panel Operation CP 3830
Press once, then select new output 2 3
1 VTR CG NET
OUTPUT
CURRENT
VCR CAM SAT
COLORBAR
FILM PATCH STU
PRESET
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−120.
To select a destination:
On a CP 3830P auto preview panel, the Preset window will display the Preset (preview) destination, and the Current window will display the Current (program) destination.
— pressing a category (e.g., “VTR”) and unit number combination, or by
— using the UP and DOWN arrows to scroll through all destinations, or by
— pressing a category key and using UP/DOWN to scroll through available units in that category; or by
— selecting a destination on the CP 3809 Expansion Panel (if so equipped—see Figure 6−122), or by
— selecting a destination on the adjacent CP 3830 dual panel (if so equipped—see below).
On a CP 3830P auto preview panel, press TAKE to change the Current (program) output; or press PRESET TAKE (CHOP button) to change the Preset (preview) output. The Current window will then show the source feeding the pro- gram output. The Preset window will show the source feeding the preview output.
Dual CP 3830 panels can be configured so that the second panel is used for output selection. The output panel’s buttons will glow amber. For configuration instructions, see page 5−126.

Control Panel Operation CP 3830
CP 3830
1 VTR CG NET
CURRENT
VCR CAM SAT
FILM PATCH STU
PRESET
TEST NUM AUX
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−121.
To select an input:
— press a category (e.g., “VTR”) and unit number combination, or
— use the UP and DOWN arrows to scroll through all sources, or
— press a category key and use UP/DOWN to scroll through the possible category entries.
...then press TAKE.
On a valid entry, the defined eight character mnemonic will be displayed in the Preset window and all applicable level lamps will light in green.
When using the UP/DOWN arrows, scrolling past the end of the list will wrap around to the other end.
The newly selected source will be shown in the Current window.
If entry of a password is requested, please see Passwords on page 6−75.
On a CP 3830P auto preview panel, you can send the selected input to the Preset (preview) output by pressing the PRESET TAKE (CHOP) button instead of the TAKE button. After previewing the source, press TAKE to switch the source to the Current (program) output.
1 VTR CG NET
CURRENT
VCR CAM SAT
1 STU
2 STU
3 STU
4 STU
FILM PATCH STU
PRESET
TEST NUM AUX
8 STU 7 STU 6 STU 5 STU
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−122. CP 3830 with CP 3809 Expansion Panel.
Before pressing TAKE, use the expansion panel to select the destination(s). The selected output button will illuminate in “High” green to show it will be affected by the switch. These buttons can be toggled on/off before pressing TAKE.

Control Panel Operation CP 3830
(To assign Expansion Panel buttons to outputs, see pages 5−79 and 6−124 (CP 3809) or 5−79 and 6−126 (CP 3810).
The present source is shown in the Current window, while the previous source is shown in the Preset window. This allows “flip−flopping” the sources, or switching between the current and preset sources by simply pressing the TAKE button.
As an example, if you wish to change the source from BARS to VTR−041, first select the VTR category. The Preset display updates as follows, prompting you to enter up to four digits:
CP 3830
COLORBAR
VCR CAM SAT
CURRENT
VTR−
FILM PATCH STU
PRESET
TEST NUM AUX
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−123.
Then press 4" and 1." The Preset display will update:
1 VTR CG NET
COLORBAR
VCR CAM SAT
CURRENT
VTR−041
FILM PATCH STU
PRESET
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−124.
To complete the selection, press the red TAKE button to switch source VTR−041 to the panel’s defined output. (On a CP 3830P, press PRESET TAKE. then TAKE.) The Preset window and the Current window will be swapped as shown, indicating to the operator the previous source can be reselected.
1 VTR CG NET
VTR−041
CURRENT
VCR CAM SAT
COLORBAR
FILM PATCH STU
PRESET
TEST NUM AUX
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−125.

Control Panel Operation CP 3830
Locking an output prevents that output from being switched by any panel in the system, including the initiating panel. In a single destination panel, it essentially locks the panel from further operator action until unlocked.
To lock an output:
This has the effect of locking only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will illuminate in “high” red, indicating the output has been locked by this panel.
If another CP 3830 panel selects this output for control, that panel’s LOCK button will blink red. If the other panel at- tempts to switch this output, a “LOCKED” message will appear, along with the name of the locking panel.
If a CP 3808 panel selects this output for control, that panel’s TAKE button will blink red (the CP 3808 has no LOCK button).
To unlock the output:
The LOCK button lamp will switch to “low” green. If the output has been locked by another panel, the button will show lock status by blinking red.
An output may be forced unlocked, no matter which panel locked it, if the password level of the unlocking panel is level 90 or greater. The password level is defined in the MPK Devices table entry (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
Protecting an output prevents that output from being switched by other panels in the system. The protecting panel may still change the outputs.
To protect an output:
This has the effect of protecting only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will blink “high” green, indicating the output has been protected by this panel.

Control Panel Operation CP 3830
If another CP 3830 panel selects this output for control, that panel’s PROT button will blink red. If the other panel at- tempts to switch this output, a “PROTECT” message will appear, along with the name of the protecting panel.
If a CP 3808 panel selects this output for control, that panel’s TAKE button will blink red (the CP 3808 has no Protect button).
To unprotect the output:
The PROT button switch to “low” green. If the output has been protected by another panel, the PROT button will show protect status by blinking red.
An output may be force unprotected, no matter which panel protected it, if the password level of the unprotecting panel is level 90 or greater. The password level is defined on the MPK Device table (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
To chop* an output, select the first source and press TAKE. Then select the second source and press CHOP. The CHOP button will blink red, with the first source displayed in the Current window, and the second source displayed in the Preset window.
The chop operation will automatically stop after approximately three minutes. The chop will finish with the source in the Preset window being switched to the destination. The chop may be manually terminated by performing another source selec- tion and pressing TAKE.
For additional chop information − see page 6−13.

Control Panel Operation CP 3830
1 VTR CG NET
CP 3830
COLORBAR
VCR CAM SAT
CURRENT
VTR−
PRESET
FILM PATCH STU
TEST NUM AUX
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−126.
Breakaways can be accomplished either by presetting the levels to switch, and then selecting a source, or by selecting a source and then deselecting unwanted levels.
Breakaways can be disabled on the CP Level Set table by setting the Break Flag for each level to ‘N.’ (See page 5−58.)
The level mnemonic appears in the Preset window and the button will illuminate in “high” green with the current status of that level in the current window. The level may be toggled off by selecting it again. The current window will be blank if there is no status for that level.
Pressing CLEAR will cancel the operation.
The source will switch only on the preset levels, while the non−selected levels will remain at the previously selected source.
The Current window will display the defined mnemonic for the first level.
To check the status of individual levels, see Status Mode on page 6−96.

Control Panel Operation CP 3830
The source mnemonic appears in the Preset window; applicable level buttons will illuminate in “high” green.
The button will switch to “low” green, and the Preset window will display the level name. Pressing CLEAR will cancel the operation.
The deselected levels will remain at the previously selected source, while the selected levels will switch to the newly selected sources.
The Current window will display the defined mnemonic for the first level.
The CP 3830 will allow operators to perform complex split switches using multiple sources on levels not defined for all sources, similar to a salvo switch to a single destination. For example, assume the user has defined Camera−1 with Video and TimeCode only levels. However, he or she desires CD−1 for audio. To perform this switch in one take:
In this example, the operator would press the buttons corresponding to Video, Left, Right, and TimeCode. The buttons will light in “high” green, indicating they are selected.
In this example, Camera−1 would be selected.
In this example, Left and Right.
In this example, CD−1 This source will automatically be assigned to the remaining levels, Left and Right audio.

Control Panel Operation CP 3830
Destination Mode — Press MENU Once
In this mode (already described on page 6−89) the destination is shown in the Preset window. (The CP 3830P will show two destinations.) If the panel is equipped with a CP 3809 Expansion, the outputs controlled by that panel will be indicated.
To return to Home mode, press CLEAR.
This mode allows the six level buttons to select and status each level.
To return to Home mode press CLEAR. (In Home mode, the six level buttons are used for splits and the UP and DOWN but- tons are used for source selection)
This mode is accessed by pressing MENU three times; the MENU button will light in red. The Current window will show the audio mode for the audio channel shown in the Preset window. In Figure 6−127, the Left audio channel is set to “Normal.”
1 VTR CG NET
NORMAL
VCR CAM SAT
CURRENT
LEFT
FILM PATCH STU
PRESET
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−127.
Other possibilities are:
MIX − Left and right are mixed on this channel. REVERSE − Signal is from the opposite channel.
The six level keys can be used to check other levels.

Control Panel Operation CP 3830
This option displays the current MPK address for this panel in the Preset window.
For a description of the diagnostics and adjustments, please see the CP 3808 Diagnostic Mode on page 6−71, starting with Step 2. Except as noted, this description applies to the CP 3830.

Control Panel Operation CP 3830
The CP 3830 has the capability of controlling Venus Audio Modes, which are Normal, Mix, and Reverse. These changes are made to individual levels prior to completing a switch by pressing the TAKE button.
The MENU button will light in red. The Current window will show the audio mode for the audio channel shown in the Preset window. In Figure 6−128, the Left audio channel is set to “Normal.”
1 VTR CG NET
NORMAL
CURRENT
VCR CAM SAT
LEFT
FILM PATCH STU
PRESET
Take VIDEO LEFT RIGHT AES1 T/C
Figure 6−128.
Left channel level key - toggle to desired stereo mode
NORMAL − Use left audio for this channel
LEFT LEFT (Left signal on Left channel)
MIX − Mix left and right on this channel
LEFT (Left + Right signals on Left channel)
REVERSE − Cross opposite channel signal over to this channel
LEFT (Right signal on Left channel)

Control Panel Operation CP 3830
NORMAL − Use right audio for this channel
RIGHT RIGHT (Right signal on Right channel)
MIX − Mix left and right on this channel
RIGHT RIGHT (Left + Right signals on Right channel)
REVERSE − Cross opposite channel signal over to this channel
RIGHT (Left signal on Right channel)

Control Panel Operation CP 3832 / 3864
The CP 3832 is a button−per−source control control panel configurable for single bus* (32 X 1) or “split” operation. In split configurations some of the buttons control inputs and some control outputs. The panel includes buttons for TAKE, LOCK,* and PROTECT.* For installation and configuration instructions, please see page 2−49.
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
VTR−041
PRESET
Figure 6−129. CP-3832.
The similar CP 3864 is configurable for single bus (64 X 1) or “split” operation. The panel has all of the CP 3832 control buttons, plus a CHOP button. A “Destination” window is also provided. For installation and configuration instructions, please see page 2−51.
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CAM1 CAM2 CAM3 CAM4
VTR−041
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
CURRENT
VTR−041
MON1 MON2 MON3 MON4
STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
PRESET
MONITOR5
MON8 MON6 MON6 MON5
EDIT1 EDIT2 EDIT3 EDIT4
KEY2 BACK
UP
BY PASS XMIT
VTR5 VTR6 VTR7 VTR8
DESTINATION
Figure 6−130. CP-3864.
All push buttons are capable of green, amber, and red back lighting. On the left side of the panel, green indicates inputs and amber indicates outputs. On the right side, green is generally used to show a selected function and red to indicate an operation- al mode in progress.
In some applications, the panels will be grouped with additional CP 3832s or CP 3864s to provide control of up to a 128 X 128 router; or, operated in connection with an adjacent CP 3810 Expansion Panel (see page 6−126).
If entry of a password (“PASS =00”) is requested, the output about to be affected has a password level higher than that of the panel. Enter the appropriate password, using the first 10 buttons of the CP 3832/64 to enter digits from 0 to 9 (as shown on page 6−144).
After entry of a higher−level six−digit password, the command can be completed by pressing TAKE; however, the panel will then revert to its previous password level.

Control Panel Operation CP 3832 / 3864
Figure 6−131. CP 3832.
(green) Figure 6−132. CP 3864.
Each input button of the CP 3832 / 3864 can be assigned to a specific source using a CP Input set (page 5−74.) The name of this set, and the name of the destination to be controlled, is entered on the MPK Devices table (page 5−110 and following).
To verify destination − for the CP 3832, press MENU. The destination will be shown in the Preset window. Then press CLEAR. On the CP 3864, the destination is always shown in the “Destination” window.
Audio−follow−video switching - (PRESET off.) When one of the source buttons is pressed, a Take* command is issued to all levels of the switcher matrix (pressing the TAKE key is not necessary). A status* signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed and displaying the name of the input in the “Current” window.
To verify a source before switching (PRESET mode) − To examine the mnemonic of a source in the Preset window before a Take, the PRESET button should be flashing red or green (press if needed). Select the desired source and check the mne- monic in the Preset window. Then press TAKE.
Breakaway switching − single level Take − (PRESET Off, or, blinking green.) To switch only a specific switcher level, the level is defined by first pressing the LEVEL button; the name of the first level will be displayed in the “Preset” window. To advance to the next level, press LEVEL again. The TAKE command to the switcher will be executed when an input button is pressed.
If the switch was made on level 1 (usually video) the new input will be displayed in the Current window. If the switch was made on another level, use the LEVEL button to return to that level; the new input will be displayed in the Current window. (To turn off the LEVEL button, press CLEAR.) Notice that only the button for the lowest level will illuminate.
Breakaway switching − multi−level Take − To switch different sources to different levels with a single Take command, press PRESET (so that the button is flashing red). Then press the LEVEL button. The name of the first level will be displayed in the Preset window. Advance to the desired level by pressing LEVEL; then select an input for that level. Press LEVEL to select another level; select the next input, etc. When all selections have been made, press TAKE.
The input for level 1 will be displayed in the Current window. To check the status of another level, use the LEVEL button to return to that level; the new input will be displayed in the Current window. (To turn off the LEVEL button, press CLEAR.) Notice that only the button for the lowest level will illuminate.
* Defined in Glossary Section
32 sources · (green) · 64 sources

Control Panel Operation CP 3832 / 3864
Figure 6−133.
To “retain” certain levels (keep them selected after a Take), press PRESET (so that the button is flashing red). Then press the LEVEL button. The name of the first level will be displayed in the Preset window. Advance to the desired level by pressing LEVEL; then press PROT/LOCK. The message “Retain” will appear briefly in the Current win- dow and the LEVEL button will blink green as an indication that sticky level switching is now in effect. Press LEV- EL to select another level; PROT/LOCK again, etc. When all selections have been made, press CLEAR.
To make a switch when sticky levels are in effect (indicated by the blinking LEVEL button), select the desired input. Only the sticky levels will switch.
To find out which levels are sticky, press PRESET, then LEVEL. If the first level is sticky, the word “Retain” will appear briefly in the Current window, if the level is not sticky, the message “No retain”will appear. Advance to the next level by pressing LEVEL; when finished, press CLEAR.
To cancel sticky levels, press PRESET, then LEVEL. The name of the first level will be displayed in the Preset window. Advance to the sticky (Retained) level by pressing LEVEL; then press PROT/LOCK to cancel stickiness. Press LEVEL to select another level; then PROT/LOCK again, etc. When finished, press CLEAR.
Breakaway statusing − To status a specific level of a previous breakaway level switch, use LEVEL to select the level to be statused; the name of the input will be shown in the Current window.
Blinking green − The output has been protected* by this panel. See Protecting or Unprotecting an Output below.
Red − The output has been locked* by this panel. See Locking or Unlocking an Output below.
Blinking red − The output has been protected or locked by another panel. To find out if the output is pro- tected, or locked, and by what panel, select an input button. Then go to that panel and refer to the appropriate section below.
Blinking LEVEL button · indicates Sticky mode

Control Panel Operation CP 3832 / 3864
To chop* an output:
The CHOP button will blink red, with the first source displayed in the Current window, and the second source displayed in the Preset window.
The chop operation will automatically stop after approximately three minutes. The chop will finish with the source in the Current window remaining switched to the destination. The chop may be manually terminated by performing another source selection.
For additional chop information − see page 6−13.
Protecting an output prevents that output from being switched by other panels in the system. The protecting panel may still change the outputs.
To protect an output:
The Preset display will ask “Lock?”
The Preset display will ask “Protect?”
This has the effect of protecting only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will blink “high” green, indicating the output has been protected by this panel. If a CP 3810 expansion panel is associated with the CP 3832/3864 panel, the output button on the expansion panel will also blink green.
If a CP 3832 or CP 3864 at another location selects this output for control, that panel’s PROT/LOCK button will blink red. If a CP 3810 expansion panel is associated with the remote CP 3832/3864 panel, the output button on the expansion panel will also blink red. If the remote panel attempts to switch this output, a “PROTECT” message will appear, along with the name of the protecting panel.

Control Panel Operation CP 3832 / 3864
To unprotect the output:
The Preset display will ask “Unprot?”
The PROT button will switch to “low” green.
If the TAKE command is ignored, the output has been protected by another panel. To find out the name of the panel, select an input button.
An output may be force unprotected, regardless of the panel that protected it, if the password level of the unprotecting panel is level 90 or greater. The password level is defined on the MPK Device table (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.
Locking an output prevents that output from being switched by any panel in the system, including the initiating panel. In a single destination panel, it essentially locks the panel from further operator action until unlocked.
To lock an output:
The Preset display will ask “Lock?”
This has the effect of locking only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will illuminate in red, indicating the output has been locked by this panel. (To adjust button brightness, see page 6−114.) If a CP 3810 expansion panel is associated with the CP 3832/3864 panel, the output button on the expansion panel will also illuminate in red.
If a CP 3832 or CP 3864 at another location selects this output for control, that panel’s PROT/LOCK button will blink red. If a CP 3810 expansion panel is associated with the remote CP 3832/3864 panel, the output button on the expansion panel will also blink red. If the remote panel attempts to switch this output, a “Locked” message will appear, along with the name of the protecting panel.
To unlock the output:

Control Panel Operation CP 3832 / 3864
The Preset display will ask “Unlock?”
The PROT/LOCK button lamp will switch to “low” green.
If the TAKE command is ignored, the output has been locked by another panel. To find out the name of the panel, select an input button.
An output may be forced unlocked, no matter which panel locked it, if the password level of the unlocking panel is level 90 or greater. The password level is defined in the MPK Devices table entry (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unlock the output prior to changing its source selection.
For additional protect/lock information − see page 6−12.

Control Panel Operation CP 3832 / 3864
Figure 6−134. Examples of CP 3832 split configurations.
Figure 6−135. Examples of CP 3864 split configurations.
In split panel applications, the buttons illuminated in green have been configured to select inputs; the buttons illuminated in amber have been configured to select outputs.
During the configuration process, EXP (expansion) is set to “Y” on the MPK Devices Table (page 5−109). The sources are defined in a CP Input set of type “cp3832” (page 5−74); the destinations are defined in a CP Output set of type “cp3832” (page 5−90).
Audio−follow−video switching - (PRESET off.) Check to see that the desired output has been selected (amber button); if not, select it now. When a source (green button) is pressed, a Take* command is issued to all levels of the switcher matrix. (It is not necessary to press the TAKE key.) A status* signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed in “high” green and displaying the name of the input in the “Current” window.
Breakaway switching − single level Take − (PRESET off.) Check to see that the desired output has been selected; if not, select it now. To switch only a specific switcher level, the level is defined by first pressing the LEVEL button; the name of the first level will be displayed in the “Preset” window. To advance to the next level, press LEVEL again. The TAKE command to the switcher will be executed when an input button is pressed.
If the switch was made on level 1 (usually video) the new input will be displayed in the Current window. If the switch was made on another level, use the LEVEL button to return to that level; the new input will be displayed in the Current window. (To turn off the LEVEL button, press CLEAR.) Notice that only the button for the lowest level will illuminate.
* Defined in Glossary Section

Control Panel Operation CP 3832 / 3864
Breakaway switching − multi−level Take − Check to see that the desired output has been selected on the bottom row; if not, select it now. To switch different sources to different levels with a single Take command, turn PRESET on (the button will flash red). Then press the LEVEL button. The name of the first level will be displayed in the Preset window. Advance to the desired level by pressing LEVEL; then select an input for that level; the selection will be shown in the Current window. Press LEVEL to select another level; select the next input, etc. When all selections have been made, press TAKE.
The input for level 1 will be displayed in the Current window. To check the status of another level, use the LEVEL button to return to that level; the new input will be displayed in the Current window. (To turn off the LEVEL button, press CLEAR.) Notice that only the button for the lowest level will illuminate.
Breakaway switching − sticky* level(s) − See page 6−102.
Split statusing − To status a specific level of a previous breakaway level switch, use LEVEL to select the level to be statused; the name of the input will be shown in the Current window.
Blinking green − The output has been protected* by this panel. See Protecting or Unprotecting an Output on page 6−103.
Red − The output has been locked* by this panel. See Locking or Unlocking an Output on page 6−104.
Blinking red − The output has been protected or locked by another panel. To find out if the output is pro- tected, or locked, and by what panel, select an input button. Then go to that panel and refer to the section on Protecting (page 6−103) or Locking (page 6−104), as appropriate.

Control Panel Operation CP 3832 / 3864
The CP 3832 / 3864 can be combined with other CP 3832s and CP 3864s to increase the number of sources and destinations to a maximum of 128 x 128. Examples are shown in Figures 6−136, 6−137, and 6−138.
CP 3832 used as source
Figure 6−136.
CP 3832 used as source
Figure 6−137.
32 destinations (amber) CP 3832 used as
Figure 6−138.
Many configurations are possible, but in all cases the buttons illuminated in green control inputs; the buttons illuminated in amber control outputs.

Control Panel Operation CP 3832 / 3864
For single−bus applications, such as illustrated in Figures 6−139 and 6−140, operation is very similar to that described on page 6−101. The main difference is that only the Main panel’s control buttons (“LEVEL,” “TAKE,” etc.) are normally used. On the expansion panel(s), the control buttons are not illuminated and the word “Source” always appears in the Preset window.
indicate Main panel All selection buttons glow green
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
VTR1 VTR2 VTR3 VTR4
CAM1 CAM2 CAM3 CAM4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
PRESET
AUX1 AUX2 AUX3 AUX4
STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VCR1 VCR2 VCR3 VCR4
VTR−001
CURRENT
KEY2 BACK
BY PASS XMIT
SOURCE
AUX8 AUX7 AUX6 AUX5
EDIT1 EDIT2 EDIT3 EDIT4
UP
VCR5 VCR6 VCR7 VCR8
PRESET
Figure 6−139. CP 3832s configured as 64 x 1 control station.
All selection buttons glow green
VTR9 VT10 VT11 VT12 VT13 VT14 VT15 VT16
VTR−001
VT17 VT18 VT19 VT20 VT21 VT22 VT23 VT24 VT25 VT26 VT27 VT28 VT29 VT30 VT31 VT32
CAM1 CAM2 CAM3 CAM4 CAM5 CAM6 CAM7 CAM8
CAM9 CM10 CM11 CM12 CM13 CM14 CM15 CM16
PRESET
MONITOR1
CG−1 CG−2 CG−3 CG−4 FDL1 FDL2 FDL3 FDL4
CG−5 CG−6 CG−7 CG−8 CG−9 CG10 CG11 CG12
DESTINATION
STU1 STU2 STU3 STU4
STU5 STU6 STU7 STU8 STU9 ST10 ST11 ST12 ST13 ST14 ST15 ST16
EDIT1 EDIT2 EDIT3 EDIT4
EDIT5 EDIT6 EDIT7 EDIT8 EDIT9 ED10 ED11 ED12 ED13 ED14 ED15 ED16
SOURCE
AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 AUX7 AUX8 AUX9 AX10 AX11 AX12 AX13 AX14 AX15 AX16
MONITOR1
BLACK BARS TONE SILE NCE EBS1 EBS2 TEST1 TEST2
UP
BY PASS XMIT
DESTINATION
Figure 6−140. CP 3864s configured as 128 x 1 control station.

Control Panel Operation CP 3832 / 3864
Source Expansion Operation (with “balanced Split” 16 x 16 Main Panel)
For expansion with balanced split§ main panel applications, such as illustrated in Figure 6−141, operation is very similar to that described on page 6−106. The main difference is that only the Main panel’s control buttons (“LEVEL,” “TAKE,” etc.) are normally used. On the expansion panel(s), the control buttons are not illuminated and the word “Source” always appears in the Preset window.
All source buttons glow green
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
SOURCE
PRESET
VTR−001
AUX1 AUX2 AUX3 AUX4
STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
CURRENT
MON1
MON2 MON3 MON4
EDIT1 EDIT2 EDIT3 EDIT4
KEY2 BACK
UP
BY PASS XMIT
VTR5 VTR6 VTR7 VTR8
PRESET
All destination buttons glow amber
Figure 6−141. CP 3832s configured as 48 x 16 control station.
§ For a discussion of balanced and unbalanced split configurations, see page 2−49.

Control Panel Operation CP 3832 / 3864
For destination expansion applications, such as illustrated in Figure 6−142, operation is very similar to that described on page 6−106. Configuration will be slightly different (since neither panel in Figure 6−142 is being used in the “split” mode).
In terms of operation, only the Main panel’s control buttons (“LEVEL,” “TAKE,” etc.) are normally used. On the expansion panel(s), the control buttons are not illuminated and the word “Destnatn” always appears in the Preset window.
All source buttons glow green
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
CURRENT
AUX1 AUX2 AUX3 AUX4
STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
PRESET
MONITOR1
AUX8 AUX7 AUX6 AUX5
EDIT1 EDIT2 EDIT3 EDIT4
KEY2 BACK
BY PASS XMIT
VTR5 VTR6 VTR7 VTR8
UP
DESTINATION
MON1 MON2 MON3 MON4
MONITOR1 STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
CURRENT
VTR5 VTR6 VTR7 VTR8 AUX1 AUX2 AUX3 AUX4
EDIT1 EDIT2 EDIT3 EDIT4
KEY2 BACK
BY PASS XMIT
DESTNATN
UP
PRESET
All destination buttons glow amber
Figure 6−142. CP 3832 used as destination panel for 64 x 32 control station.

Control Panel Operation CP 3832 / 3864
Destination Mode — Press MENU Once
In this mode the destination is shown in the Preset window. If the panel is equipped with a CP 3810 Expansion, the outputs controlled by that panel will be indicated.
To exit this mode, press CLEAR.
This mode is accessed by pressing MENU twice; the MENU button will light in red and the Preset window will display the name of the first audio level. The Current window will show the audio mode for that level. In Figure 6−143, the Left audio channel is set to “Normal.”
CURRENT
LEFT
PRESET
Figure 6−143.
Other possibilities are:
MIX − Left and right channels are combined on this channel.
REVERSE − Channels are swapped.
To move beyond the first audio level, use the LEVEL button.
This option displays the name of the panel as entered on the MPK Devices table.
This option displays the current MPK address for this panel in the Preset window.
Level Menu Clear · Prot/ Lock Pre− · set Take

Control Panel Operation CP 3832 / 3864
To exit the diagnostics mode press CLEAR at any time. (It may be necessary to press CLEAR twice.)
This test cycles through the button lamps (LEDs) and illuminates them in green and then red. The test will stop after one cycle. Pressing CLEAR during this test will cancel this test and return the panel to the beginning of the current diagnostic. Pressing CLEAR again will exit the Diagnostic mode.
Info displays the panel’s Application (PROM) version , Xilinx FPGA* version, Variant version (not implemented), and PCB (hardware) version. Press CLEAR to exit.
When selected, this option displays the current baud rate for the panel. Press LEVEL to cycle through the baud rate settings. Available baud rates are: 38400, 19200, 9600, 4800, 2400, and 1200. Pressing TAKE will program the changed setting; CLEAR will cancel.
The baud rate must agree with the setting for the CM 4000 port used by the panel (see Serial Protocol on page 5−30).
This diagnostic requires the panel be disconnected from the MPK data cable.
When selected, this option displays the current MPK address for this panel and permits entry of a new address. Use the top row of buttons to enter a hexadecimal address (see Figure 6−144).
0 1 3 3 4 5 6 7 8 9 A C B D E F Level Menu Clear
PRESET
Figure 6−144. CP 3832 buttons used to enter hex address. CP 3864 buttons are similar.
The CP 3264 panel operates in a similar manner.
Pressing TAKE will program the newly entered address; CLEAR will cancel.
* Defined in Glossary section

Control Panel Operation CP 3832 / 3864
The address must agree with the setting for the panel on the MPK Devices table (see page 5−107).
This diagnostic requires the panel be disconnected from the MPK data cable.
This test allows the factory to test the MPK connection on the control panel.
This option allows the user to change the “Low” and “Medium” levels of green button illumination, the “Low” and “Medium” levels of red button illumination, and the level of LED (display character) illumination. The “High” button levels are not ad- justable.
The “Low” green level is used for normal button lighting. “High” green and “high” red are also used, but these are not adjust- able.
For each setting, use the LEVEL button to increase brightness and PRESET to decrease. Press TAKE to save the setting and advance to the next color. Press CLEAR to exit.
This test rotates through the button lamp and Display tests continually. Press CLEAR to cancel.
This diagnostic displays the number of each button as it is pressed. Pressing the LEVEL key will change the lamp color. Press- ing CLEAR twice exits.
This test cycles through and displays all legal characters. The test will stop after one cycle. Pressing CLEAR exits. (On the CP 3810, press the CLEAR button twice to exit.)

Control Panel Operation CP 3832 / 3864
The CP 3832/64 has the capability of controlling Venus Audio Modes, which are Normal, Mix, and Reverse. These changes are made to individual levels prior to completing a switch by pressing the TAKE button.
To perform a special stereo switch:
The MENU button will light in red and the Preset window will display the level mnemonic. The Current window will show the audio mode for the left channel.
In Figure 6−145, the left audio channel is set to “Normal.”
CURRENT
LEFT
PRESET
Figure 6−145.
NORMAL − Use left audio for this channel
LEFT LEFT (Left signal on Left channel)
MIX − Mix left and right on this channel
LEFT (Left + Right signals on Left channel)
REVERSE − Cross opposite channel signal over to this channel
LEFT (Right signal on Left channel)
Level Menu Clear · Prot/ Lock Pre− · set Take

Control Panel Operation CP 3832 / 3864
NORMAL − Use right audio for this channel
RIGHT RIGHT (Right signal on Right channel)
MIX − Mix left and right on this channel
RIGHT RIGHT (Left + Right signals on Right channel)
REVERSE − Cross opposite channel signal over to this channel
RIGHT (Left signal on Right channel)

Control Panel Operation CP 3832L / 3864L
The CP 3832L is a CP 3832 panel configured so that the right−hand group of six buttons function as level selection buttons.
The CP 3832L is a button−per−source control control panel configurable for single bus* (32 X 1) or “split” operation. In split configurations some of the buttons control inputs and some control outputs. For installation and configuration instructions, please see page 2−49.
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CURRENT
LEFT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
PRESET
Figure 6−146. CP-3832.
The CP 3864L is a CP 3864 panel configured so that the upper right−hand group of six buttons function as level selection buttons and the adjacent lower button functions as a Protect key. (The Lock function is not available for this panel.)
The CP 3864L is configurable for single bus (64 X 1) or “split” operation. A “Destination” window is also provided. For installation and configuration instructions, please see page 2−51.
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
RIGHT
MON1 MON2 MON3 MON4
STU1 STU2 STU3 STU4
PST PGM AIR KEY1
VTR1 VTR2 VTR3 VTR4
PRESET
MONITOR5
MON8 MON6 MON6 MON5
EDIT1 EDIT2 EDIT3 EDIT4
KEY2 BACK
BY PASS XMIT
VTR5 VTR6 VTR7 VTR8
DESTINATION
UP
Figure 6−147. CP-3864.
The Password function is limited to the password level assigned to the panel on the MPK table. It isn’t possible to enter a supervisory password to temporarily raise the password level of the panel.

Control Panel Operation CP 3832L / 3864L
Figure 6−148. CP 3832L.
(green) Figure 6−149. CP 3864L.
Each input button of the CP 3832L / 3864L can be assigned to a specific source using a CP Input set (page 5−74.) The name of this set, and the name of the destination to be controlled, is entered on the MPK Devices table (page 5−110 and following).
To verify destination (CP 3864L only) − On the CP 3864, the destination is always shown in the “Destination” window.
Audio−follow−video switching − When one of the input buttons is pressed, a Take* command is issued to all levels of the switcher matrix. A status* signal is then returned to the control panel; this confirms the action by lighting the selected input button and displaying the name of the input in the Current window.
Split switching − When the operator desires to take only specific switcher levels, those levels are defined by first pressing one or more of the six level breakaway buttons. The Take command to the switcher will be executed when an input button is pressed. The switcher will confirm the action by lighting the selected input button. Since the panel always operates in “sticky level” mode, the selected level buttons will remain lit after the input button has been pressed.
Split statusing − To status a specific level of a previous breakaway level switch, select the level to be statused; one of the input buttons will illuminate and the Current window will indicate the source for that level. If more than one level status button has been toggled on (like A1 and A2), only the lowest level (A1) will be statused.
* Defined in Glossary Section
32 sources · (green) · 64 sources

Control Panel Operation CP 3832L / 3864L
CP 3832L
A CP 3832L will indicate when another panel has protected (or locked) an output by flashing the last selected input button. The CP 3832L cannot protect/unprotect (or lock/unlock) an output.
Protecting an output prevents that output from being switched by other panels in the system. The protecting panel may still change the output.
To protect an output with the CP 3864L:
This has the effect of protecting only those levels this control panel can control (as defined on the CP Level set assigned to the panel). The button will blink “high” green, indicating the output has been protected by this panel. In addition, the associated input button will also blink green.
If another panel attempts to switch this output, a “Protected” indication will appear on that panel.
To unprotect the output:
The Protect button will switch to “low” green.
If the Protect command is ignored, the output has been protected by another panel. To find out the name of the panel, select an input button.
An output may be force unprotected, regardless of the panel that protected it, if the password level of the unprotecting panel is level 90 or greater. The password level is defined on the MPK Device table (page 5−107). This operation is useful for a master panel capable of switching any source to any destination. The operator would be required to force unprotect the output prior to changing its source selection.
If another panel has protected (or locked) the output, the CP 3864 Protect button will blink red. In addition, the last selected input button on the CP 3864L will blink green.
The CP 3864 cannot lock or unlock an output.
For additional Protect information − see page 6−12.

Control Panel Operation CP 3832L / 3864L
Figure 6−150. Examples of CP 3832L split configurations.
Figure 6−151. Examples of CP 3864L split configurations.
In split panel applications, the buttons illuminated in green have been configured to select inputs; the buttons illuminated in amber have been configured to select outputs.
During the configuration process, EXP (expansion) is set to “Y” on the MPK Devices Table (page 5−109). The sources are defined in a CP Input set of type “cp3832” (page 5−74); the destinations are defined in a CP Output set of type “cp3832” (page 5−90).
Audio−follow−video switching - Check to see that the desired output has been selected (amber button); if not, select it now. When a source (green button) is pressed, a Take* command is issued to all levels of the switcher matrix. A status* signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed in “high” green and displaying the name of the input in the “Current” window.
Breakaway switching − single level Take − Check to see that the desired output has been selected; if not, select it now. To switch only a specific switcher level, the level is defined by first pressing the appropriate level button; the name of the fir st level will be displayed in the “Preset” window. The Take command to the switcher will be executed when an input button is pressed.
* Defined in Glossary Section

Control Panel Operation CP 3832L / 3864L
Breakaway switching − multi−level Take − Check to see that the desired output has been selected on the bottom row; if not, select it now. To switch different levels with a single command, press the first desired level button. The name of the first level will be displayed in the Preset window. Press the next desired level button, etc. When all selections have been made, perform the switch by pressing an input button.
Split statusing − To status a specific level, select the desired level button. The name of the input will be shown in the Current window. Then toggle off the level button. To status another level, select another level button, toggle the button off, etc.
Although the CP 3832L and 3864L do not have “Menu,” “Level,” etc. buttons as such (because the buttons are used as level selection keys), the “Diagnostic” functions are still available indirectly. To access these functions, the MPK cable on the rear of the unit must first be disconnected. Then use the buttons as described below.
PRESET
Figure 6−152. CP 3832L buttons as used during Diagnostic Mode.
PRESET
DESTINATION
Figure 6−153. CP 3864L buttons as used during Diagnostic Mode.
To exit the diagnostics mode press “Level 3” at any time. (It may be necessary to press Level 3 twice.)
This test cycles through the button lamps (LEDs) and illuminates them in green and then red. The test will stop after one cycle. Pressing Level 3 during this test will cancel this test and return the panel to the beginning of the current diagnostic. Pressing Level 3 again will exit the Diagnostic mode.
Info displays the panel’s Application (PROM) version , Xilinx FPGA* version, Variant version (not implemented), and PCB (hardware) version. Press Level 3 to exit.

Control Panel Operation CP 3832L / 3864L
When selected, this option displays the current baud rate for the panel. Press Level 1 to cycle through the baud rate settings. Available baud rates are: 38400, 19200, 9600, 4800, 2400, and 1200. Pressing the “Level 6” button (CP 3832L) or the “Pro- tect” button (CP 3864L) will program the changed setting; Level 3 will cancel.
The baud rate must agree with the setting for the CM 4000 port used by the panel (see Serial Protocol on page 5−30).
When selected, this option displays the current MPK address for this panel and permits entry of a new address. Use the top row of buttons to enter a hexadecimal address (see Figure 6−144).
0 1 3 3 4 5 6 7 8 9 A C B D E F
PRESET
Figure 6−154. CP 3832 buttons used to enter hex address. CP 3864 buttons are similar.
The CP 3264 panel operates in a similar manner.
Pressing the “Level 6” button (CP 3832L) or the “Protect” button (CP 3864L) will program the newly entered address; Level 3 will cancel.
The address must agree with the setting for the panel on the MPK Devices table (see page 5−107).
This test allows the factory to test the MPK connection on the control panel.
This option allows the user to change the “Low” and “Medium” levels of green button illumination, the “Low” and “Medium” levels of red button illumination, and the level of LED (display character) illumination. The “High” button levels are not ad- justable.
The “Low” green level is used for normal button lighting. “High” green and “high” red are also used, but these are not adjust- able.
For each setting, use the Level 1 button to increase brightness and Level 4 to decrease. Press the “Level 6” button (CP 3832L) or the “Protect” button (CP 3864L) to save the setting and advance to the next color. Press Level 3 to exit.
* Defined in Glossary section

Control Panel Operation CP 3832L / 3864L
This test rotates through the button lamp and Display tests continually. Press Level 3 to cancel.
This diagnostic displays the number of each button as it is pressed. Pressing the Level 1 key will change the lamp color. Press- ing Level 3 twice exits.
This test cycles through and displays all legal characters. The test will stop after one cycle. Pressing Level 3 exits.
Burn In · Keyboard Test · Display Test

Control Panel Operation CP 3809
The CP 3809 can be used as a companion to the CP 3808 Switcher Control Panel or to the CP 3830 Control Panel. Each button on the CP 3809 panel represents a destination, with the display line above providing status. Up to five CP 3809 panels can be associated with a CP 3808 or CP 3830, providing up to 40 outputs for control. Figure 6−155 illustrates a control panel array for CP 3809 control of 16 outputs.
For multi−bus control the desired source can be selected on the CP 3808/3830; the CP 3809 would then be used to select the destination(s). The selected output button will glow “high” green to show that it will be affected by the switch. To complete the switch, the operator presses the TAKE button on the CP 3808/3830. (This action does not affect the output being controlled by the CP 3808 or CP 3830.)
EJ
VTR−041 CAM−002
VCR NET REM
FILM
1 STU
2 STU
3 STU
4 STU
FS
TEST PTCH CGEN
8 STU 7 STU 6 STU 5 STU
9 STU
10 STU
11 STU
12 STU
16 STU 15 STU 14 STU 13 STU
Figure 6−155. CP 3808/E (top) with CP 3809/1 Expansion Panel (below)
The process of assigning outputs to the expansion panel is the same as assigning the output to be controlled by the CP 3808/3830, except that the desired button is pressed on the expansion panel (rather than TAKE on the main panel):
For details concerning this procedure, see page 6−65 (CP 3808). or page 6−76 (CP 3830).
To check the new assignment, press MENU.

Control Panel Operation CP 3809
Deleting an Output on TAKE Key
To delete an output that has been dynamically assigned to the expansion panel, use the CP 3808/3830 to select an output that is not defined and press the appropriate button on the expansion panel.
Outputs can also be assigned permanently, using the CP Output Set. See page 5−79.
Since there are no output displays, Grass Valley recommends fixing these outputs in the CP Output Set and installing perma- nent labels in the buttons.
On the CP 3809, diagnostics mode is entered by pressing and holding the first button while pressing the eighth button.
For a description of the diagnostics and adjustments, please see the CP 3830 Diagnostic Mode on page 6−87, starting with Step 2. Except as noted, this description applies to the CP 3809.

Control Panel Operation CP 3810
The CP 3810 panel can be associated with a CP 3832, CP 3864, CP 3808, or CP 3830 Main panel, providing control of up to 80 outputs. The CP 3810 can be configured as a “CP 3810L,” allowing it to be assigned to one output; this provides break- away (split) switching and/or multi−level status. Alternatively, it can be configured as a “CP 3810S,” meaning that the se- lected outputs will remain selected until explicitly changed by the operator.
The CP 3810 can also be used as a limited−function machine control panel, providing Play and Stop commands for VTRs.
Figure 6−156 illustrates a CP 3810 with a CP 3832 panel.
CAM1 CAM2 CAM3 CAM4
BLACK BARS TONE CG−1 SILE NCE CG−2 CG−3 CG−4
CURRENT
VTR5 VTR6 VTR7 VTR8
CAM5 CAM6 CAM7 CAM8
EBS1 EBS2 TEST1 TEST2 FDL1 FDL2 FDL3 FDL4
PRESET
VTR−001 P=01
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
PLAY/ STOP
Figure 6−156. CP 3832 with CP 3810 (bottom).
For a general description of the CP 3810, and hardware installation instructions, see page 2−54. For software configuration instructions (MPK table), see page 5−131.
To assign CP 3810 buttons to outputs, see page 5−79.
Configuration for machine control applications and the method by which machines are assigned to the panel are discussed on page 5−148.
When configured for multi−bus control, the status of eight buses will normally be seen in the CP 3810’s eight−character dis- play windows. The “page” of status of eight destinations can be scrolled with the arrow buttons to display up to 80 possible destinations; the current page number is shown in the window above the DEST button.
To verify destinations − For the CP 3810, press DEST; the destinations will be shown in the eight display windows. The “page” of eight destinations can be scrolled with the arrow buttons to display up to 80 possible destinations. To return to status mode, press DEST again. For the Main panel, press MENU, then CLEAR.

Control Panel Operation CP 3810
PRESET OFF method. See Figure 6−157.
[2]
[3]
Figure 6−157. Switching with Preset OFF.
The “page” of eight destinations can be scrolled with the arrow buttons to display up to 80 possible destinations. The selected output button(s) will glow “high” green to show it will be affected by the switch.
When one of the source buttons is pressed, a Take command is issued to all levels of the switcher matrix. (Press the TAKE key is not necessary.) A status signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed and displaying the name of the input in the “Current” window of the Main panel and the appropri- ate windows on the CP 3810.
This action does not affect the output being controlled by the Main panel.
If the CP 3810 has been configured for “sticky output” operation (CP 3810S), selected outputs will remain selected until the Take/Select button(s) are toggled off.
If entry of a password is requested on the Main panel (“PASS =00”), the output about to be affected has a password level higher than that of the panel. For more information about passwords, refer to the operation instructions for the Main panel.
Select destination(s) · Select source
![Page 476 of the 3Com CM 4000 user manual — [3] [4]](/cdn/reader/bb/bb95f49739aea1e5b5d629b2ae4814a7cc290cbaf11b6b8492d4208a28c906c3/images/page-476.webp?w=400)
Control Panel Operation CP 3810
PRESET ON method. See Figure 6−158.
PRESET ON Select source
Figure 6−158. Switching with PRESET ON.
The “page” of eight destinations can be scrolled with the arrow buttons to display up to 80 possible destinations. The selected output button(s) will glow “high” green to show that it will be affected by the switch.
A status signal is then returned to the control panel; this confirms the action by lighting the input button that was pressed and displaying the name of the input in the “Current” window of the Main panel and the appropriate windows on the CP 3810.
If the CP 3810 has been configured for “sticky output” operation (CP 3810S), selected outputs will remain selected until the Take/Select button(s) are toggled off.
If entry of a password is requested on the Main panel (“PASS =00”), the output about to be affected has a password level higher than that of the panel. For more information about passwords, refer to the operation instructions for the Main panel.
Select destination(s) · Press TAKE

Control Panel Operation CP 3810
In the example shown in Figure 6−159, a CP 3832 is used to select inputs and a “CP 3810L” is used to control the individual levels of one output. The CP 3810 can thus be used for breakaway switching.
To find out what output is being controlled by the CP 3810, use the “show destination” procedure for the Main panel. In the example shown in Figure 6−159, the CP 3832 MENU button would be pressed.
PRESET OFF method. See Figure 6−159.
[2]
Select level(s) (If no levels are selected, all levels
will switch.)
Figure 6−159. Switching with Preset OFF.
PRESET ON method. See Figure 6−160.
Figure 6−160. Switching with PRESET ON.
Select a single level (If no levels are selected,
If desired,select another level and source
switch.)

Control Panel Operation CP 3810
In the example shown in Figure 6−161, a CP 3864 is used to select inputs, a CP 3832 is used to select outputs, and a “CP 3810L” is used for control/status the individual levels of the output selected by the CP 3832. The CP 3810 can thus be used for break- away switching.
Once a destination has been selected, the switching procedure is similar to that just described (page 6−129). The “page” of eight levels can be scrolled with the arrow buttons to display additional levels.
In this mode, a “CP 3810L” is configured to status the output assigned on the MPK Devices table. No other panel is associated with the panel and there is no switcher control.
STATUS of individual levels
To verify levels, press DEST. The level names will be shown in the eight display windows.
On the CP 3810, diagnostics mode is entered by pressing and holding the first button on the left while pressing DEST. This will display the Panel (Device) Name and the Panel ID (Address) from the MPK Devices table. To clear the ID and enter the Diagnostic mode, press DEST again. Use the soft−keys labelled with the UP and DOWN arrows to to select the desired diag- nostic; press the TAKE soft−key to start the diagnostic.
For a description of the diagnostics and adjustments, please see Diagnostic Mode on page 6−112.
Please refer to the JEP 100 manual, part no. 071 8376 xx.

Control Panel Operation MC 3000
REC MODE << >> > >
REC OUT
REC
Figure 6−163. MC 3000 machine control panel
Status STOP STOP STOP VT01 VC01 VC02 Device
> ∧ ∨
Figure 6−164. CP 3010 expansion panel
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
TAKE −−−−−−
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
Installation of these panels has already been described (page 2−37).
The MC 3000 machine control panel includes a series of push buttons for motion control (PLAY, STOP, etc.). A variable speed knob, with a color−coded direction/speed indicator, is also included.
The machine to be operated can be selected using the adjacent CP 3010 expansion panel (Figure 6−164), which can display the names of eight linked machines over a row of selection buttons. Additional pages of eight machines can be called up for display in the window as required.
The method by which machines are linked (assigned) to the CP 3010 is described in detail elsewhere in this manual (see As- signing Machines to Control Panels on page 5−141). Essentially, each TAKE/SELECT button is “associated” with a particu- lar output of the routing switcher and switching a VTR to that output will cause the VTR to appear over the button. This “fol- low−the−switcher” concept should be understood before operating either of these panels.
The CP 3010 can also be used as a limited−function machine control panel, providing Start and Stop commands for VTRs.

Control Panel Operation MC 3000
RDY
Toggles the machine in and out of scanner ready mode.
Stops machine regardless of mode.
Playback mode. May or may not override current mode, depending on machine.
Slow motion playback. Speed is indicated in the display window.
May or may not override current mode, depending on machine. When first pressed, speed will be 1/5 or +0.2 play speed. Typical speed range, using variable speed knob, is −1 to +3 times play speed.
Captures current time code.
The actual value will depend on the machine and interface used. For more infor- mation, see Appendix E.
Go to time code point captured with Set Mark command, minus Preroll value set on the Machine Control Devices table, and stop. For more information, see Pre- roll on page 5−140.
For more information, see Appendix E.
End record mode (same as ESbus Exit command). Normally used to terminate an Insert edit, in which case machine drops out of record mode but keeps on play- ing.
When machine is stopped, pressing RECORD OUT also serves to place machine in Tape Monitor mode.
> · >

Control Panel Operation MC 3000
IN
When pressed at the same time as PLAY, starts record mode and illuminates Re- cord LED. Same as ESbus Play and Enter.
When machine is stopped, pressing RECORD IN places machine in E−E Monitor mode.
Select a recording mode. Depending on the machine, pressing the button will cy- cle through the following, as indicated in the display window:
Off − Record inhibit.
Manual − Pressing PLAY and RECORD IN will begin a recording, during which no editing functions will be enabled.
Assemble − Pressing PLAY and RECORD IN will begin an Assemble edit.
Insert − Pressing PLAY and RECORD IN will begin an Insert edit.
Full−speed shuttle (rewind or fast forward); speed is shown in the display win- dow. Speed can be reduced by variable speed knob; direction can be reversed if desired.
Press both buttons at once for Jog (frame advance). Direction and speed is deter- mined by variable speed control. (This is supported for true ESbus controlled VTRs only, e.g., DCR 500.)
Shuttle mode can be entered by turning the knob more than approx. 30 degrees.
Press both buttons at once for Diagnostic mode. Diagnostics are similar to those supplied with the MC 3010 (as described on page 6−137). To exit individual diag- nostics, use the Fast Forward ( >> ) key. To exit diagnostic mode, press both Ready and Fast Forward at the same time.
and
>>
Using the MC 3000 to Access Sony Auto−Edit Mode
To mark the edit beginning point, press the SET MARK key. Use any method to reach the edit ending point on the tape. To mark the end point and initiate the edit, press and hold REC IN, then press PLAY, then release both buttons. The VTR will rewind to the edit begin point minus the set preroll time, go into Play mode, and at the edit beginning point (where you pressed SET MARK) go into Record mode. It will stay in Record until the edit ending point (where you pressed REC IN + PLAY), at which point the VTR will continue on for a few frames, then go into Variable Play, rewind to the edit ending point, then stay in Variable Play with a velocity of 0.00.
or · Shuttle knob

Control Panel Operation MC 3000
The method by which machines are linked (assigned) to the CP 3010 is described in detail elsewhere in this manual (see As- signing Machines to Control Panels on page 5−141). Linkage is indicated by the name of the machine appearing in the display window.
When a machine name appears in the window, pressing SEL enables Start/Stop control (described below). It also enables control using the adjacent MC 3000 Ma- chine Control Panel (if any). The TAKE legend does not apply to machine control.
SEL
Starts machine shown in window.
Stops machine shown in window.
Scrolls window up to next page of machine names.
Scrolls window back one page.
> · ∧ · ∨

Control Panel Operation MC 3010
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
STOP −−−−−−
READY −−−−−−
REC −−−−−−
SHIFT
REW
FFD
SHIFT
REW
FFD
SHIFT
REW
FFD
SHIFT
REW
FFD
PLAY GANG START PLAY GANG START PLAY GANG START PLAY GANG START
Figure 6−165. MC 3010/2 Dual 4−Machine Control Panel
Installation of these panels has already been described (page 2−37).
The MC 3010 is used to control four (MC 3010/1 version) or eight (MC 3010/2 version) tape machines. The display window shows the name of the machine presently linked to the button group immediately below. Lighted, re−legendable push buttons are provided for motion control (PLAY, STOP, etc.). Machine commands and status indications are shown in Figure 6−166.
The method by which machines are linked (assigned) to the MC 3010 is described in detail elsewhere in this manual (see Assigning Machines to Control Panels on page 5−141). Essentially, each button group is “associated” with a particular output of the routing switcher and switching a VTR to that output will cause the VTR to appear over the button group. This “follow− the−switcher”concept should be understood before operating the panel.
To send the same command to more than one machine, toggle on the GANG START key for each desired machine. Then press the appropriate command key (RECORD, STOP, etc). All following commands will be sent to all marked machines until the GANG START keys are toggled off.
Gang Start commands will be applied to marked machines on both left and right halves of a dual panel.

Control Panel Operation MC 3010
Press System response (status)
STOP −−−−−−
SHIFT
SHIFT
READY −−−−−−
READY −−−−−−
REW
PLAY
PLAY
REC −−−−−−
REC −−−−−−
FFD
PLAY
PLAY
STOP −−−−−−
READY −−−−−−
SHIFT
REW
STOP −−−−−−
REC −−−−−−
press & hold then press
FFD
Figure 6−166. MC 3010 Operation and status

Control Panel Operation MC 3010
The diagnostics mode allows several panel functions to be checked without sending any machine commands.
Figure 6−167. Keys used to enter diagnostic mode.
DISPLAY KEYBOARD LAMPS
READY −−−−−−
READY −−−−−−
READY −−−−−−
REW
REW
REW
Figure 6−168. Diagnostic menu. Press appropriate READY/REWIND key to select test.
Display The display test will cycle through the character set used in the display window and repeat. To exit to the diagnostic menu (Figure 6−168), press any READY/REWIND key.
Keyboard The keyboard test will report the key number of each button pressed. To exit to the diagnostic menu, press any READY/REWIND key twice.
Lamps After starting the lamp test, it will take about 10 seconds for the first MC 3010 key to light. To exit to the diagnostic menu, press any READY/REWIND key.
To exit the diagnostic mode, repeat the step shown in Figure 6−167. (If in keyboard test (as indicated by a “Key =” message), you must first press any READY/REWIND key twice.)
press & hold · then press

Control Panel Operation VGA Display
The VGA Status Display provides a supervisory, system−wide display of switcher, machine, or system status. The display video is provided by the VGA output of a CM 4000. The display format is initially based on a set of factory default pages, but can be customized as needed. (For more information about installation and configuration, see Appendix A.)
Basic controls for this display are located on the front panel of the CM 4000 (Figure 6−169).
Figure 6−169. VGA controls on CM 4000
For easier operation, the CM 4000 can be connected to one CP 3020 control panel, which in this application is configured as device type “VC 3020” (see Figure 6−170). To use the VGA to best advantage, it should also be connected to a CP 3000 Switcher Control Panel and an MC 3000 Machine Control Panel. The RGB display monitor and the controls just described should be located as close together as possible, preferably in the same equipment rack.
Philips WXYZ TELEVISION ROUTER/VTR STATUS PAGE: 00 May 10, 1999 SWITCHER STATUS 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− OUTPUT VIDEO LEFT RIGHT TC −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PrdA VT01 PrdB VC01 VC01 VC01 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1
Figure 6−170. VGA Status Display control panel arrangement.
NEXT CURSOR
CHNG MODE 0 9 1 2 3 4 5 6 7 8
CP 3020 control panel, showing suggested labels for VC 3020 application
The VGA display starts up on Page #0 as defined in the VGA Page Description File. Display pages 0−9 are selected with the number buttons.

Control Panel Operation VGA Display
The following discussion is based on the factory default set of display pages.
Thomson WXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 01 May 10, 1999 MAIN Switcher Output Status 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− OUTPUT VIDEO LEFT RIGHT TC −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PrdA VT01 PrdB VC01 VC01 VC01 PrdC Cam1 Cam1 Cam1
Figure 6−171. Switcher out- put status page (example)
A switcher output status page (Figure 6−171) can provide a list of switcher outputs and the name of the input switched to each. Separate columns for each level can be used to report split switches; these can be highlighted with a distinct color.
An alternating (flashing) display indicates that the output is locked or protected:
NEXT is used to cycle through additional logical switchers (if any). UP and DOWN (or the arrow buttons on the CP 3020) will step through additional pages of outputs; hold the key down to auto−repeat.
To enter cursor mode, press SELECT on the CM 4000 (or CURSOR MODE on the CP 3020). This will cause the name of the first output to appear in reverse video. The UP and DOWN buttons (or arrow buttons) will move the cursor from one output to another. An output pointed to by the cursor is automatically selected as the output to be controlled by the CP 3000 Switcher Control Panel associated with the CM 4000 providing the VGA display.
Levels · Inputs · Outputs

Control Panel Operation VGA Display
As a supervisory system, the VGA / CP 3000 can be configured such that it can unprotect or unlock any output shown on the display.
— If the panel has been so configured on a permanent basis (as described on page 5−114), place the cursor on the
output and press PROTECT (or LOCK) and TAKE.
— If the panel has not been configured permanently, login to the panel using a 90 level or above password. This
will allow use of the force unprotect/unlock command until logout.
For additional protect/lock information − See page 6−12.
Thomson WXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 01 May 10, 1999 MACHINE & DELEGATION STATUS 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− MACHINE STATUS LINKAGE MCS STU ENG TAPE −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− VT01 STOP StuMC StuMC VT02 VT03 VT04 VT05 VT06 VT07 VT08 VT09 VC01 STOP StuMC ASSIGNED VC02 STOP ASSIGNED VC03 VC04 VC05
Up to 32 Delegation
Figure 6−172. Machine & delegation status page (example).
A machine and delegation status page (Figure 6−172) can provide a list of all VTRs and other machines listed on the Machine Control Devices table (page 5−135). The UP and DOWN buttons (or arrow buttons on the CP 3020) will step through addi- tional pages of machines. Hold the key down to auto−repeat.
Depending on the machine, TMC (Transport Motion Control) status is shown as follows:
OFF NOT REM EJECT STOP STOP−RDY PLAY VAR PLAY FAST F REWIND SHUTTLE + SHUTTLE −
To enter cursor mode, press SELECT on the CM 4000 (or CURSOR MODE on the CP 3020). This will cause the name of the first machine to appear in reverse video. When in cursor mode, the UP and DOWN buttons (or arrow buttons) will move the cursor from one machine to another. A machine pointed to by the cursor is automati- cally selected as the machine to be controlled by the adjacent MC 3000 Machine Control Panel (i.e., the MC 3000 connected to the CM 4000 providing the VGA display).
groups

Control Panel Operation VGA Display
This function is available with the CP 3020 panel only.
While in Cursor Mode, the CHANGE MODE button can be used to “un−delegate” a machine. To do this, the cursor is moved to the row showing the desired machine, then, using the RIGHT and LEFT keys, to a delega- tion group column showing the word “Assigned” or the showing the name of the panel now linked to the machine. When CHANGE MODE is pressed, the delegation/link will be cut and the VG 3000/MC 3000 will have exclusive control. If CHANGE MODE is pressed again, the machine will again be delegated to the group shown at the top of the column; however, another associative switcher Take will have to occur to re− establish the link.

Control Panel Operation VGA Display

The Software Control Panel Suite (“Graphical User Interface”) consists of seven routing switcher and machine control applications plus a configuration application. Only one of the applications can be activated at a time.
The software operates on a PC using the Jupiter Network Suite (JNS) software, which provides the interface to the Jupiter Control system through the Jupiter LAN. The Software Control Panels are designed for mouse or touchscreen opera- tion.§ The panels can be run on the Jupiter file server, on one or more separate PCs on the Jupiter LAN, or on both.
The control panels obtain configuration set information from the Jupiter control system file server, allowing the user to maintain a central configuration control point even with multiple control panel PCs operating on the LAN. The software provides a means for licensing and operation of multiple copies of the control panel software on a single Jupiter system.
Software installation is described in the Field Engineering Bulletin supplied with the software.
If the software panels are to be used for switcher control only, no Jupiter table entries are required. However, the panels will require the use of existing CP Level, Input, and Output sets.
If the panels are to be used for machine control, a Configuration Set must be selected for editing and entries describing the PC and the machine control panels must be made to the following tables:
Network Description table Serial Protocol table MPK Devices table
§ For touchscreen operation, the PC and monitor must be supplied by Grass Valley.

Software Control Panel Suite
Machine Control Devices table
These entries are described on the following pages. Guidelines for using the table editor are found on page 5−3.
For information about management of Configuration Sets, including compiling and activating sets, see page 5−8.
Redn Board Name PC1 PC
192.168.253.2
Figure 7−1.
Board Name Create a name for the PC that will display the Software Control Panels.
For Jupiter naming rules, see page 5−7.
Type Select board type “PC.”
Address Enter the IP address of the PC (e.g., “192.168.253.2”).
To find out the IP address, go to Start > Programs > Jupiter Network Suite > JNS Configuration.
In some cases, there may be two network cards installed—one for Jupiter and another for a facility LAN. If you are not sure which address is correct for the Jupiter card, try looking at Network Neighborhood > Properties (right click for Properties), then Protocols > TCP/IP Protocol > Properties > Adapter; usually the Jupiter card will be a 3Com. Click on 3Com to see the IP address of the card.
Network Description · Address 1 Type

Software Control Panel Suite
Proto 1/2 Name PC1 MPK 1 3/4 UND
7/8 UND
9/10 UND
11/12 UND
13/14 UND
15/16 UND
38.4 3/4 UND
5/6 UND
Figure 7−2.
Name Enter the name of t7he PC displaying the Software Control Panels. This must be the same as that entered on the Network Description table (Figure 7−1).
Proto 1/2 Select “MPK” for ports 1/2. Leave the other ports undefined.
Baud 1/2 Select “38.4” for ports 1/2. Leave the other ports undefined.
Serial Protocols · Baud 1/2

Software Control Panel Suite

Dev Name Dev Type Exp PW Board Port Address Inp Set Out Set Lev Set Over Set Seq Set
Figure 7−3.
Dev Name There must be an entry for at least one CP 3xxx control panel that is capable of machine con- trol and that has Input, Output, and Level Sets assigned. (This is true even if no physical panel actually exists.) A CP 3800 panel is shown in this example.
You must also create a name for each of the six Slaved Machine Control panels.
Dev Type For the slaved machine control panels, select “MC−3000.”
Exp For the software machine control panels the entry is always “N.”
Board For the slaved machine control panels, enter the name of the PC that will display the software panels; this must agree with the PC’s Board Name entered on the Network Description table (page 7−2).
Port For the slaved machine control panels, there must be an entry in each of these fields to satisfy the compiler.
Address For the slaved machine control panels, there must be a unique entry in each of these fields to satisfy the compiler.
Inp Set Out Set Lev Set These fields are the source for the set names that appear on the Panel Config- uration screen (page 7−7). For the six Slaved Machine Control panel entries, these fields must be blank.

Software Control Panel Suite

Figure 7−4.
Dev Name Enter the Device Name for each of the six Slaved Machine Control panels. These must agree with the names entered on the MPK devices table.
Dev Type Select “MC−3000.”
Board Enter the Name of the PC that will display these panels. This must agree with the PC’s Board Name entered on the Network Description table (page 7−1).
Port Address To satisfy the compiler, there must be a unique entry in these fields and this entry must agree with the corresponding entry on the MPK table. In this example, “PC1MC1” has the Address “01010101” on both tables.
I/O Select “Out.”
For information about management of Configuration Sets, including compiling and activating sets, see page 5−8.

Software Control Panel Suite
At the end of the installation process, the Software Panels program can be launched using the JNS Console, in the “JNS Applications” program group. (For more information about the JNS Console, see Section 4.)

Figure 7−5.
The Main Screen provides the ability to access each of the installed GUI applications. The GUI buttons on the screen indicate that the application is configured and ready for use by changing the label text from shaded to black.

Software Control Panel Suite
When the “Configure” button is selected, a password screen will appear. When the system is first configured, the screen will have a “New Password” box and a “Confirm Password” box.
— If a password is desired, enter up to eight alphanumeric characters (case sensitive) and re−enter to con-
firm. Then select “Apply.” The screen shown in Figure 7−6 will appear.
— If no password is desired, just select “Apply.” The screen shown in Figure 7−6 will appear.
The Panel Configuration screen displays the CP Input, Output and Level sets found on the active MPK table. The selected sets will be used for all software panels in the system.

After highlighting the desired sets, select “Back” to activate the sets and return to the Main Screen.
Although the Software Control Panels can use sets originally created§ for any CP 3xx or CP 3xxx control panel, the ideal sets would be those created for use with an existing CP 3800 panel. Since such sets can include 20 categories and eight−character mnemonics, they would allow you to take full advantage of the Software Con- trol Panel’s capabilities.†
Figure 7−6. Panel Configuration screen.
Note: the CP Output set selected here must have a least one output assigned to one of the first 16 categories in the set, otherwise no output can be selected for control. For example, if a type 3800 output set is selected, it must have at least one output assigned to a category in the outlined group shown in Figure 7−7:
Figure 7−7.
VTR CG NET SAT A VCR CAM REM EMER B FILM PTCH STU FS C AUX TEST MISC SS D
§ In this application, use of sets that were created for one panel type and later copied for use with another type should be
avoided.
† If no such sets exist, you may want to create eight−character Input/Output/Level sets of type CP 3800 and assign them to an
imaginary device of type CP−3800. For information about creating these sets, see CP Level sets (page 5−58), CP Input sets (page 5−62) and CP Output sets (page 5−78). Keep in mind that an imaginary device entered on the MPK table must have corresponding entries on the Serial Devices table!

Software Control Panel Suite
Following configuration, any one of the following panels can be selected:
Each of these panels is described in the following pages.
If you have a large system, it can take quite a while for the system to apply configuration data to a panel when you first start it. If you are running remotely, the delay will be somewhat longer because the panel must load configuration information from the file server. This delay can be made worse if you have a lot of applications running on the file server. The Jupiter Configuration Editor in particular requires a large amount of processor time. If you are running GUI panels either on the file server, or remotely, you should close the Jupiter Configuration Editor. In addition, you should close down any unnecessary applications on the file server.
After a panel is started, select the Back button to return to the Main screen.
To switch between windows, press ALT+TAB. To return to the software panel, click anywhere within the panel display.
On some computers, you can display the Windows task bar on the bottom of the screen by pressing the Windows logo key and TAB. (You can’t minimize the Software Control Panel screen.)
These messages will be shown for approximately four seconds if a switch fails for one of these reasons. This applies to the Full Panel, X−Y Panel, Source Destination Panel and the Dubs Panel. “Paths Full” means that no Tie Lines are available; “Protected” means the output is protected by another panel; “Locked” means the output is locked by another panel; “Ex- cluded” means the switch is prohibited by an entry in the Exclusion table. All GUI Panels that are on the same output as the GUI Panel that requested the switch will display these messages. For additional Protect/lock information see page 6−12.

Software Control Panel Suite

Figure 7−8.
The Slaved Machine Control panel provides the ability to control up to six machines from a single screen. The panel includes a Gang button for slaving machines together.
To link to a machine, select the “Machine” window; a drop down list will show the machines entered on the Machine Control table of the active configuration set (see page 5−135).
Select the desired machine. If linkage is established, the appropriate motion control button will turn yellow; if time code is present it will be displayed as well.
If an attempt is made to take control of a machine that has a “default” (semi−permanent) link to a specific control panel, the link will not occur; instead, a message will indicate the name of the controlling device. For more information about default links, see page 5−146.

Software Control Panel Suite
Gang Allows a machine control command to be sent to more than one machine.
Stop Stops machine regardless of mode
Play Playback mode. May or may not override current mode, depending on machine.
REW or FF Full speed shuttle (rewind or fast forward)
Ready Toggles the machine in and out of scanner ready mode
The time code display window will display hours, minutes, seconds and frames. In some modes the frames are not dis- played.
Time code display

Software Control Panel Suite
Level 1 Preset Level 1 Status

Multi−level Status Multi−level Preset
Figure 7−9.
This panel provides full matrix control with breakaway switching capability. Memories allow the user to Save/Recall up to four sets of 12 Direct Take inputs per output.
The Categories section will be rewritten to display the categories available to the operator, up to a maximum of 16. The Function buttons will change from white to gray to indicate they are inactive.
The Entries section will be rewritten to display up to 15 destination buttons. Additional Destination buttons, if avail- able are accessed by using the scroll buttons.
The destination entry will be entered into the Destination display and the level 1 status will be shown in the Status window. In addition, the status for each level will be shown in the “Levels” window with yellow lettering; the name of each level will be shown on the buttons. If more than four levels exist a scroll button will appear.

Software Control Panel Suite
The Categories section will be rewritten to display all source categories available to the operator. The Function but- tons will change from gray to white to indicate they are active.
The Source Entries section will be rewritten to display up to 15 source buttons. Additional Source buttons, if avail- able, are accessed by using the scroll buttons.
The Status display will change to the new source indicating the switch was made. The Preset display will change to the previously selected source. Flip−flop switching between the old and new source is accomplished by pressing the Take button again.
Paths Full / Protected / Locked / Excluded messages − see page 7−8.
When only one level is to be switched, the following method is suggested:
— If the destination needs to be changed, select it at this time.
— The “Source” button lettering should be yellow (active). If not, select it.
— The Preset windows should be blank. If not, click the Clear All button. Then:
The name of the source will appear above the Level button just selected.
The name of the source will move to the multi−level status window.
Flip−flop switching between the old and new source is accomplished by pressing the Take button again.

Software Control Panel Suite
When more than one level is to be switched, the following method is suggested:
— If the destination needs to be changed, select it at this time.
— The “Source” button lettering should be yellow (active). If not, select it.
The name of the source will appear above all the Level buttons.
This will erase the name of the source above the Level buttons just deselected.
The names of the new sources will move to the multi−level status window.
Flip−flop switching between the old and new sources is accomplished by pressing the Take button again.

Software Control Panel Suite
The Full Function Switcher Panel has the capability of controlling Venus Audio Modes, which are Normal, Mix, and Reverse. These changes are made to individual levels prior to completing a switch by pressing the TAKE button.
To perform a special stereo switch:

Figure 7−10.
In Figure 7−10, the left audio channel is set to “Mix.”
NORMAL−use left audio for this channel
LEFT LEFT (Left signal on Left channel)
MIX− Mix left and right on this channel

Software Control Panel Suite
LEFT (Left + Right signals on Left channel)
REVERSE− Cross opposite channel signal over to this channel
LEFT (Right signal on Left channel)
NORMAL−use right audio for this channel
RIGHT RIGHT (Right signal on Right channel)
MIX− Mix left and right on this channel
RIGHT RIGHT (Left + Right signals on Right channel)
REVERSE− Cross opposite channel signal over to this channel
RIGHT (Left signal on Right channel)
A letter “M” (mix) or “R” (reverse) will appear in the Levels Status display.
To clear the special mode, perform another switch (with the Audio Modes button off).

Software Control Panel Suite
Direct Take Preset Assignments
The Presets Function allows the user to save frequently−used sources in a 12−button Direct Take Presets window. Four of these Direct Take setups may be saved.
All buttons in the Functions section are toggle function, i.e. select to turn On and select again to turn Off.
The Presets button label color will change from white to red and the Direct−Take Presets window will appear.

Figure 7−11.
The button label color will change from black to yellow indicating that sources may be assigned to the Direct Take buttons. If the Unload function was active it will be deactivated, indicated by the label color changing from yellow to black.
The Source Entries section will be rewritten to display the source buttons.

Software Control Panel Suite
The source entry will be entered into the Preset display.
The Source name will be written to the button.
A Direct Take button may be reassigned to a new source using the normal assignment procedure.
Direct Take assignments that are not saved in Memory will be erased when you exit the Software Control Panel application.
To assign Breakaway Selections to Direct Take buttons, follow the “Breakaway Switching” procedure on page 7−12 ex- cept for selecting Take at the end. Instead, select the Presets and Load buttons and then the desired Direct Take button to assign the breakaway selection. The Direct Take button source label will be displayed as red characters indicating that a breakaway switch is assigned to this button.
The breakaway setup may be checked on any Direct Take button by activating the Presets window, then the Levels win- dow, and selecting the Check Preset button. The Check Preset button label color will change from black to yellow indicat- ing the function is active. Select the Direct Take button of the source to be checked. The source names will be shown on the Level buttons. The Check Preset button will change from yellow to black indicating the function is no longer ac- tive.
Removing a Preset Assignment
To remove a source from a Direct Take button, select Unload in the Functions section. The button label color will change from black to yellow indicating the function is active. If the Load function was active, it will be deactivated, indicated by the label color changing from yellow to black.
Select the desired Direct Take button. The source name on this button will be cleared. The Unload button label color will change from yellow to black indicating the function is no longer active.
Switching Using the Direct−Take Presets
Select the Presets button in the functions section. The button label color will change from white to yellow and the Direct Takes section will be displayed. Select the desired Direct Take button. The switch will be immediate.
The Status display will change to the new source indicating the switch was made. The Preset display will change to the previously selected source.
Breakaway Preset Assignments

Software Control Panel Suite
Switching using the Categories/Source Entries section remains active.
The memory window allows the user to save or recall up to four sets of 12 Direct Take setups.
Saving a Direct Take Setup
The Memory button label color will change from white to red and the Memory window will appear.

Figure 7−12.
The label will change from black to yellow.
The setup will be saved in the selected location. Also, a “Recall” and a “Clear” button will now appear.

Software Control Panel Suite
Recalling a Direct Take Setup
The Categories section will be rewritten to display all source categories available to the operator. The Function but- tons label color will change from gray to white to indicate they are active.
The Memory button label color will change from white to red and the Memory window will appear.
The Memory button selected will change from black to yellow.
The Memory button label will change from red to white and the Memory store window will be replaced with the Direct Take display window which will contain the recalled Direct Take setup entries.
Select the Memory button, then select the label adjacent to the desired Memory 1, 2, 3, or 4 button. Use the computer keyboard to enter an 8 character (minimum) user specified name. Select Store. Select Memory to close the display win- dow.
Memory Location Labeling

Software Control Panel Suite

Figure 7−13.
The Full Function Machine Control screen provides the user with control of one machine at a time. The screen includes an eight−character display for selecting and displaying current machine linkage, twelve machine control buttons, a nu- meric keypad for entering time code values, a time code readout, and a motion control knob with direction and speed indicators.
To link to a machine, select the “Machine” window; a drop down list will show the machines entered on the Machine Control table of the active configuration set (see page 5−135).
Select the desired machine. If linkage is established, the appropriate motion control button will turn yellow; if time code is present it will be displayed as well.
If an attempt is made to take control of a machine that has a “default” (semi−permanent) link to a specific control panel, the link will not occur; instead, a message will indicate the name of the controlling device. For more information about default links, see page 5−146.

Software Control Panel Suite
Ready Toggles the machine in and out of scanner ready mode.
Stop Stops machine regardless of mode.
Play Playback mode. May or may not override current mode, depending on machine. Shuttle knob remains centered.
Record Immediately begins recording.
Search Go to the time code point captured with Mark, minus the Preroll value set on the Ma- chine Control Devices table.
REW or FF Full speed shuttle (rewind or fast forward). Control knob remains centered.
Go To Go to the time code entered using the keypad.
Mark Captures current time code if the system uses serial time code interface and time code is being fed from machine.
Rec In Immediately begins recording.
Rec Out Exit Record mode (same as ESbus Exit command). Normally used to terminate an In- sert edit, in which case the machine drops out of record mode but keeps on playing.
Mode (When enabled) Select a recording mode:
Off = record Inhibit.
Manual = pressing REC IN followed by PLAY will begin a recording, during which no editing functions will be enabled.
Assemble = pressing PLAY and REC IN will begin an Assemble edit.
Insert = pressing PLAY and REC IN will begin an Insert edit.
Control Knob and Direction/speed Indicators
The control knob and and the direction/speed indicators are used for the Variable play, Rewind, and Fast Forward and functions. The shuttle function is controlled by rotating the control knob. Stop by pressing the top center mark or the Stop button.
The time code display window will display hours, minutes, seconds and frames. In some modes, the frames are not dis- played.
Manual Time Code Entry
The keypad is used to enter an eight−digit time code; the Go To button can then be used to move to that time.
Time Code Display

Software Control Panel Suite

Figure 7−14.
The Dubs screen provides the ability to switch the same source to multiple destinations with a single Take.
Additional Destination buttons, if available, are accessed by using the scroll buttons. The label of the selected but- ton will change from black to yellow and the entry name will be written in the Destination display. The panel Status display will always indicate the source status for the last activated destination button.

Software Control Panel Suite
Additional Destination Entries buttons, if available, are accessed by using the scroll buttons. The label of the se- lected buttons will change from black to yellow and the entry name of the last destination selected will be written in the Destination display. The Status display will be rewritten to provide current source status.
To cancel a single output selection, select that button again.
To cancel all Destination Entries select Clear.
The Source Entries section will be rewritten to display up to 12 source buttons.
The source entry will be entered into the Source Preset display.
The Status display will change to the new source indicating the switch was made. The Preset display will change to the previously selected source. Flip−flop switching between the old and new source will be accomplished by selecting the Take button again.
Paths Full / Protected / Locked / Excluded Messages − see page 7−8.
When Hold is pressed, the button label will change from white to red indicating that the selections made in the Destination Entries section cannot be inadvertently changed.
Select the Hold button again to toggle the function off. The Hold button label will change from red to white indicating the Hold function has been disabled and the selections in the Destinations Entries section can be modified.

Software Control Panel Suite

Figure 7−15.
The Source/Destination panel provides full−matrix routing switcher control using Category and Entry buttons.
The Categories section will be rewritten to display all categories available to the operator.
The Entries section will be rewritten to display up to 24 destination buttons. Additional Destination buttons, if available, are accessed by using the scroll buttons.
The destination entry will be entered into the Destination display and the Source display will be rewritten to provide current status.

Software Control Panel Suite
For more information, see “To Status a Destination” above.
The Categories section will be rewritten to display all categories available to the operator.
The Source Entries section will be rewritten to display up to 24 source buttons. Additional Source buttons, if avail- able, are accessed by using the scroll buttons.
The source entry will be entered into the Preset display.
The Status display will change to the new source indicating the switch was made. The Preset display will change to the previously selected source. Flip−flop switching between the old and new source is accomplished by pressing the Take button again.
Paths Full / Protected / Locked / Excluded Messages − see page 7−8.

Software Control Panel Suite

Figure 7−16.
The Salvo screen provides the ability to switch multiple source/destination combinations with a single Take.
Additional Source Entries buttons, if available, are accessed by using the scroll buttons. The label of the selected button will change from black to yellow. Selection of a different source will deselect the previous source selection.
Each source/destination entry will be entered automatically in the Salvo list window in the lower center of the dis- play.
Additional Destination Entries buttons, if available, are accessed by using the scroll buttons. The label of the se- lected button will change from black to yellow. Additional destinations can be switched to the currently selected source by selecting the desired Destination Entries buttons. The button label will change from black to yellow for each selected destination. To remove a destination from the switch setup select that button again. This will deselect that output and change the button label from yellow to black.

Software Control Panel Suite
The memory window allows the user to save or recall up to four sets of Salvo setups.
Saving a Salvo Setup
The Memory button label color will change from black to yellow and the Memory window will appear.

Figure 7−17.
The label will change from black to yellow.

Software Control Panel Suite
The setup will be saved in the selected location.
Checking a Salvo Setup
Recalling and taking a Salvo Setup
Select the Memory button, then select the label adjacent to the desired Memory 1, 2, 3, or 4 button. Use the keyboard to enter an 8 character (minimum) user specified name. Select Memory to close the display window.
Memory Location labeling

Software Control Panel Suite

Figure 7−18.
The X−Y Panel is similar to the Source/Destination panel but has one set of category and entry buttons for the source and another set for the destination.
The Destination Entries section will be rewritten to display up to 12 destination buttons. Additional Destination buttons, if available, are accessed by using the scroll buttons. Status for the first level will be shown on the button.
If the button is selected, the destination will also appear in the Destination display and the Current Source display will indicate current status.
The selection will appear in the Source Preset display.

Software Control Panel Suite
The Current Source display will change to the new source indicating the switch was made. The Preset display will change to the previously selected source. Flip−flop switching between the old and new source will be accomplished by pressing the Take button again.
Paths Full / Protected / Locked / Excluded Messages − see page 7−8.

This application displays board status and information. It can be used to help make certain that all system controllers are using compatible software and user−created configuration sets, and that enough free memory is available for the system to operate properly.
Since most of this information also appears in the Control Center, this application will eventually be phased out.

Figure 8−1.
The first column lists board names in the order that they appear in the Network Description table.
The second column shows the name of the board’s operating system code file. This file is found in the jupiter\bin directory and is downloaded to the board if the file changes or you clear the flash on the board.
The third column shows the Ethernet hardware address for the board.
The fourth column shows ticks, which is an approximate indication of the board’s up−time. There are approximately 60 ticks/ second in NTSC and approximately 50 ticks/second in PAL.
The fifth column shows board status. The field is green if the board is active and red if the board is inactive.
The fifth and sixth columns show the CRC for the board’s application and configuration files. If these match what the file server has for the active set, the fields will be green. Otherwise, the fields are red—indicating the need for a fresh download to all boards.
The “...MemAvail” fields show how much memory each board has for application, heap, configuration, and PMEM.

The Version field shows what version of application code each board is running. This should indicate the same version for all boards in the system. If not, a fresh download to all boards should be performed.
The example above (Figure 8−1) shows a set that has 5 PCs in the Network Description table. Board Status cannot show in- formation for PCs.
The Board Status application does not poll for board information. Click on the Refresh button to refresh the display.
Exit - close the application.
Alarm Enabled - this enables or disables an audible alarm. If a board is inactive, or if its code or configuration CRCs do not match the file server’s active set, the application will beep if the alarm is enabled.
About - this displays the application’s about box with version information.

The JNS Control Center, which replaces the JNIA Control Center, has four tabs:

Figure 9−1.
The Board Status tab shows board status and up−time.
The first column lists the board names in the order that they appear in the Network Description table (note that PC boards do not appear here).
The second column shows the board status. The fields will be green if the board is active. If boards are inactive, “Inactive” will appear in the field and the field will be red. If a board is currently downloading, “LOADING...” will appear in the field, and the field will be cyan.
The third column shows how long the boards have been up in days, hours, minutes and seconds. For the up−time display to be accurate you must have selected the correct Scan Rate option in the options menu (see below).
* See Glossary.


Figure 9−2.
This table shows TFTP status while the boards are in the process of downloading.
The first column shows the boards in the order that they appear in the Network Description table (again, PCs do not appear).
The second column shows the name of the file that the board is downloading. In the example above, you can see some boards downloading their configuration files (.cfg), one board downloading code (.sys), and two boards have just finished download- ing loader code (.ldr).
The third column shows the status of the transfer. On a busy system, you may occasionally see packet timeout counts. This indicates that the file server has missed responses from a board. This does not necessarily indicate a serious problem. Packet timeouts frequently occur on very busy systems. When a transfer succeeds, the “Transfer succeeded. packets timed out.” message will be displayed and the field will be green. If the transfer fails, the field will turn red, and a description of the prob- lem will appear in the field. This may be a temporary condition. The boards will usually attempt to start new transfers in this case, and the field will turn green again as the new transfer starts. A very large number of timeouts or frequent transfer failures could indicate problems with your network or configuration.
The fourth column shows what percentage of the file has been sent.
JNS Control Center


Figure 9−3.
This application can be used to help make certain that all system controllers are using compatible software and user−created configuration sets. It also allows you to send commands to the boards.
The first column of the table shows board names in the order that they appear in the Network Description table (PCs do not appear).
The second column displays the current IP address of the board.
The third column indicates whether the board’s configuration set matches the active set on the file server. If the sets match, “OK” appears in the field and the field is green. If they don’t match, the field is red and “MISMATCH” appears. This status will usually appear if you activate a new set without rebooting. If the board is downloading or inactive, the field is cyan and “?” appears.
The fourth column shows whether the board’s operating system code matches the code on the file server. Indicators are the same as for the Configuration column.
You must select boards before you can send commands to them. To select individual boards, click anywhere in that board’s row in the table. The selected board will appear in a darker gray in the Board column and the board’s IP address field will turn blue. To de−select a board, click in the row again.
JNS Control Center

To select all the boards, click on the Select All button. To de−select all boards click on the Unselect All button.
This button sends a reboot command to the selected boards only. This differs from the Reboot button on the Configuration tab, which sends reboots to all boards.
This button clears PMEM on the selected boards.
This clears flash memory on the selected boards and reboots them. The boards will immediately begin downloading all config- uration and code.
This starts the post−mortem debugger on the selected boards.
Start Board Override is a troubleshooting tool intended for programmer use. When the Start Board Override button is selected, and a board selected and booted, the basic operating system will launch but the Jupiter processes will not start. Boards in this state will display a Probe message similar to “pmemOverrideStartBoard is set, not starting this board.” Using Probe, one can enter “startBoardOverrideShow” from the shell to determine if the board will or will not start up on the next reboot. Once troubleshooting is completed, one can either reboot the board (which will automatically “start” all processes), or use the Probe command “startBoard” to resume normal board operation.
Probe connections are described in Appendix C.
This opens telnet windows for the selected boards. For this command to work, you must have a “telnet.exe” application some- where in your search path. The default TCP/IP Windows installation will do this for you. Note that if you have selected several boards, the telnet windows may appear on top of each other. Simply move them to see the ones underneath.
This requests updated board information from the boards. The control center does not poll for board information. It does at- tempt to update board information when boards become active, but the display may occasionally show incorrect information. If you suspect this, click on the Update Board Info button.
JNS Control Center

Several commands are accessible through the control center’s menu:
This closes the application.
You must select the correct scan rate for your system for board up−time to be displayed correctly:
NTSC - Select this if you use NTSC. PAL - Select this if you use PAL.
This item does not apply to CM 4000 units (it is used by the VM 3000, which is described in a separate manu- al).
For a discussion of time sources and synchronization for AccuSwitch applications, see Appendix G.
About - Displays the Control Center’s About box with version information.

Figure 9−4.
The Configuration tab allows you to see a list of compiled sets and select a set for activation. It also allows you to restore a previously activated set and reboot the boards.
On the left side of the window, you will see a box that shows a list of compiled sets. To activate a set, click on the set name in the list, make sure the Select and Reboot radio button is selected, and click on the Activate button. A status dialog will appear while the set activation is occurring:

Figure 9−5.
Once set selection completes, the following dialog will appear:

Figure 9−6.
At this point, a reboot command will be sent to all the boards in the set, and the boards will reboot and download the new set.
JNS Control Center

Though the “Configuration” tab gives no indication of activity during file transfers, other tabs (described above) can be used to determine when it is safe to initiate some other command. Depending on a several factors such as the number of boards, configuration size, need to update the *.sys file, LAN transmission rate, LAN traffic, etc., a complete set change can take several seconds or multiple minutes.
Selecting the “Select Set Only” radio button will prevent the Control Center from sending a reboot to the boards after a set activation. Keep in mind that the active set will not match what is on the board. If any boards reboot after this time, they will download the new set, but they will not match other boards that have not rebooted. This can cause system instability. For this reason, you should not usually leave the file server in this state. Reboot all boards as soon as possible.
Clicking on the “Reboot” button sends a reboot command to all the boards. If the boards do not have the currently active set, they will download the new set.
Whenever you activate a set, the name of the new set appears in the Current Set box and the name of the old set appears in the Backup Set box.
To restore a backup set, click on the Restore Backup button. The backup set will be made the active set. The name of this set will now appear in the Current Set box, and the Backup Set: box will be cleared. Note that the Control Center does not “swap” sets. That is, the set that was active before you clicked on Restore Backup does not become the backup set.
The “On Activation” radio buttons have the same effect for restoring backups as they do for activating sets. That is, if the “Select and Reboot” radio button is selected when you restore a set, the backup set will be made active, and a reboot command will be sent to the boards. Otherwise, the set will be activated but no reboot command will be sent.
JNS Control Center

JNS Control Center

The Control Panel Input/Output Set Editor (sometimes referred to as the “Active Editor”) allows special CP I/O Sets to be created and downloaded to the system controllers without using the Jupiter Configurator or the Control Center (see Figure 10−1). Since the download is limited to these special sets, the download process occurs much more rapidly than it would other- wise. Modifications such as assigning a new category/number to an input, or changing a mnemonic, can thus be made without affecting on−air operation or taking the control system down. It is also possible to edit Category names.
set selected for editing
Copy of Active Set Select and
Figure 10−1.
SET EDITOR
The user first selects an existing CP I/O Set from the active configuration set, then creates a copy for exclusive use by the CP I/O Set Editor. The copy is then modified and activated (downloaded). The set (or sets) are sent to the controller board’s PMEM, overriding the current input or output sets.
Since the modified set information is kept in PMEM, it will be preserved in the event of a power loss. However, it will be lost if PMEM is cleared.
Important: Sets modified with the CP I/O Set Editor will no longer match those in the original Jupiter Configura- tion Set. This creates a situation where, for example, Selected Set “config01” seen by the Jupiter Configurator does not match Current Set “config01” seen by the Control Center. A good practice is to reconcile these sets as soon as possible by using the Jupiter Configuration Editor to modify the original CP I/O Sets. This will avoid the poten- tial confusion of having two versions of the same set.

JNS CP I/O Set Editor
The CP I/O Set Editor is launched using the JNS Console, in the “JNS Applications” program group. (For more information about the JNS Console, see Section 4.)
When the CP I/O Set Editor is started, the system presents a log in dialog:

Figure 10−2.
— If the CP I/O Set Editor has never been run before, you must create an administrator Name. If you want to
create a Password, enter the password (up to eight characters) and press OK. Or, if you don’t want a password established, just select OK.
— If you are logged in as the administrator, and want to add a new user, go to “Options > Passwords.” You will see
a list of all users. Note that the first person in the list (the administrator) is always assigned a security level of “4.” Only those with a security level of 4 can add new users. As administrator, you can also delete users and re−assign passwords.
— If you need a password, or forget your password, contact the administrator. If you are the administrator and
have forgotten the administrator password, contact Grass Valley Technical Support for assistance. (Rebooting or re−installing software will not restore the password system to its original state.) For more information about passwords, see page 10−8.
After entering the appropriate password, the main window is displayed (Figure 10−3). On entry, no set selected, and the main window is empty. The “Edit Set” child windows will not appear until sets are selected for editing, or new ones created.

Figure 10−3.
File
Select Edit Set − Allows the user to open (edit), delete, copy, and create new CP I/O Set Editor sets (see page 10−3).

JNS CP I/O Set Editor
Select Group − Allows CP I/O Set Editor sets to be grouped and activated (downloaded) (see page 10−5).
Activate Sets − Can be used to activate individual CP I/O Set Editor sets (see page 10−7).
Close/Save − These options are only available when an set is open. “Save” makes the modified set information available for activation.
Print Log − Allows the user to specify a log file to print (see page 10−7).
Print Setup − Standard Windows dialog for printer selection, etc.
Log In − Following a Log Out, allows a user to log in and use the CP I/O Set Editor (see page 10−8).
Log Out − Logs the user out of the CP I/O Set Editor (see page 10−8).
This displays the Input and Output Set Usage table (see page 10−11).
Passwords − This menu displays the password window and allows an operator to add or delete users (see page 10−8).
Compare Sets − Allows the user to compare two sets and print the results (see page 10−9).
Generate Log − Toggles the generation of log entries (on/off) when sets are activated. This can only be changed by users with level 4 privilege.
Check for duplicates − This option is only available when an edit set is open. Selecting this menu option checks the currently active set for duplicate entries.
Settings − Shows the current user and allows setting the activation timeout interval and the session privilege level.
“File > Select Edit Set” brings up a menu similar to the following:

Figure 10−4.
Exit

JNS CP I/O Set Editor
This dialog lists the sets that have been created for use with the CP I/O Set Editor (when first opened, the list will be empty.) From here, you can edit existing sets, delete and copy sets, and create new sets.
To create a new set, select New. The following dialog is displayed:

Figure 10−5.
This table shows the CP I/O Sets that are in use by the active (“Current”) Set. (The name of the Current Set is shown in the Control Center menu; the names of the CP I/O sets are shown on the MPK Devices table). To create a new set for the CP I/O Set Editor, select a set, enter a Name, and select Create. The program will create a copy of the selected input or output set, and then display an edit window for that set.
To edit an existing CP I/O Set Editor set, select a row on the Select Set menu, and select Edit. An example of a CP input set is shown in Figure 10−6.

Figure 10−6.

JNS CP I/O Set Editor
The Edit Set window for output sets is similar, except that the Category/Entry numbers are grayed out (cannot be changed). The Level Set and Button assignments are shown but cannot be changed.
On an Input set table, selecting the Category field displays a drop−down list of categories; Entry numbers are typed in. The Mnemonic column contains simple edit fields. The Input/Output field is a combo box that lists all switcher inputs or outputs. You can select an input or output or type one.
There are two additional fields per row that are not contained in the active set: Password Level and Comment. The Password Level ranges from 1 through 4, 1 being the default. The Password Level prevents users with lower passwords from changing entries that are protected with a higher password level. (Password Levels are assigned in the Options menu; for more informa- tion see page 10−8.) The Password Level drop−down list contains the numbers 1 through the level of the current user.
On Input sets only, you can insert new rows using the Insert key or the Insert Row command from the Edit menu, or, delete rows with the Delete key or the Delete command.
To save the set(s), select “File > Save.” (This does not download the sets.)
To change the name of a category or add a new category, select a set for editing, then go to “Edit > Edit Categories.” After making the change, select OK.
Note: After you have selected “OK,” be sure to save the set using “File > Save.” If you close the set without saving, further editing will be confusing because two versions of the category name will exist in the system. To correct this situation, you must return to “Edit > Edit Categories” and re−enter the old name of the category (as shown in the window with the name of the set in the upper left corner), then click OK; then return to “Edit > Edit Catego- ries” and make the desired change.
In most cases, you will want to create an input set and an output set and manage them as a unit. For example, during a particular show or production project you may want to use special mnemonics for sources and destinations.
The Group function allows you to group input and output sets and name the group (after the name of the project, for example). Thus the sets can edited and activated together.
“File > Select Group” displays a window similar to the following (when first opened, the list will be empty):

Figure 10−7.

JNS CP I/O Set Editor
To create a new group, select the New button. The following dialog is displayed:

Figure 10−8.
Enter a new name and select OK. The group will be created and the Edit Group dialog will be displayed (Figure 10−9).

Figure 10−9.
The left column shows all the CP input and output sets. The right−hand column shows all the sets in this group. To add sets to the group, select one or more entries from the left−hand column and click the >> button. To remove sets, click on one or more set names in the right column and click the
To edit the sets in the group, select a group in the Select Group dialog and click the Edit Sets button. An edit window will appear for each set in the group (see “Editing Sets” above).
To immediately activate (download) all the sets in a group, select the Activate button in the Select Group dialog. During this process, the following dialog is then displayed:

Figure 10−10.
This dialog displays the names of all boards in the active set, and the status of the transfer. The status will display as follows:

JNS CP I/O Set Editor
READY − The board has received the new control panel set, or the board does not need the set. The set will only be sent to boards that require it.
NO MEMORY − The board has reported back that there is insufficient memory to download the selected sets. The board will not be downloaded at this time.
UNKNOWN − The board is not responding. If a board has not responded within 15 seconds, this will change to INACTIVE.
The OK button is disabled until the process has completed.
It is also possible to activate sets individually, as described below.
To activate individual input or output sets, go to “File > Activate Sets.”

Figure 10−11.
Select one or more “Replacement Set” fields and select a set name. Click the Activate button. The system will ask for verifica- tion. If you elect to proceed, the information will be sent to the controller boards and a Sending Status display will appear (as described on page 10−6).
After the sets are activated two log files will be written to the Jupiter/AppData/IOEdit directory. The first contains the set names and group names. The second log file contains the actual sets that have been sent. Both files will have a date and time stamp, along with the name of the user who did the activation as a header field, and will be comma delimited (CSV) for export- ing to other applications. The name of the file will be the same, with the extension describing the log file type. The file names will be:
Lxxxxxxx.nam
Lxxxxxxx.set
where xxxxxxx is a seven digit sequential number starting at 0000000, going to 9999999. These log files can be printed from the “File” menu.

JNS CP I/O Set Editor
Logging In
The user must log into the system to be able to edit and activate sets and groups. When the user selects the “Log In” option from the File menu, he will be prompted with the following dialog:

Figure 10−12.
The user will be required to enter his or her log in name and password. The system password level will be set to the user’s password level.
Passwords are up to eight characters in length and can be any alphanumeric character. This includes special DOS filename characters such as ‘*’, ‘\’, etc. The user will be prompted to enter a new password twice for validation purposes.
When the user logs out of the system, no changes can be made. The login screen will be displayed.
Without being logged into the system, the user can view the input and output usage tables. If the application is running and no changes or activations have occurred within the last 15 minutes, the operator will have the option to stay logged in or auto- matically log out. This option will be available for only 30 seconds. If there is no operator intervention, the system will log out the user and the login window above will be displayed.
Passwords
The user logged in must have a password level of 4 to use all options available in this window. Otherwise the options will be grayed out, indicating they cannot be selected. Any user will be able to change their own password; all other operations are password level dependent. On validation of password level, the password table will be displayed:

JNS CP I/O Set Editor

Figure 10−13.
The window contains a list of users and their password levels. Actual passwords are not displayed in this window. Each pass- word is assigned a level 1 through 4. This level determines the entries in the table that the operator has authority to change. Level 4 is the highest and can change any entry. Level 3 can change levels 1, 2, and 3. Level 2 can change levels 1 and 2, while level 1 passwords can only change level 1 entries.
A level 4 user can add, delete, or change entries in the password table by selecting the entry and then the Add, Delete, or Change buttons. Adding or changing entries will bring up the following window:

Figure 10−14.
This dialog contains a 20 character (maximum) name, an eight character (maximum) password, and a single digit level. Levels are entered using a drop−down box.
This option provides a comparison utility between two sets. The sets must be of the same type; i.e. both input sets or both output sets. The Compare Sets window shown provides the user with a complete list of sets.

JNS CP I/O Set Editor

Figure 10−15.
Highlight the two sets for the comparison and press the Compare button to start the comparison. The following comparison window will be displayed:

Figure 10−16.
The comparison list shown puts the two sets together for scrolling purposes. Various highlight shadings are used to distinguish between items added, changed, or deleted. Care will be taken to display only the changes made. However, if the files are out of synchronization, the resulting list could be misleading.
To print the comparison results, select the Print button. Otherwise, when done, press the Close button. The system will return to the previous menu to allow additional set comparisons.

JNS CP I/O Set Editor
Input/Output Set Usage, from the View menu, shows where inputs are and outputs are being used.

Figure 10−17.
This window is displayed when the user se- lects an input. It displays all the control panel input sets where the input is used.
1. The CP I/O Set Editor does not know when a PMEM Clear is done on a controller board. This means that if there were any edit sets on the board before the PMEM clear the editor still thinks they are on the board; therefore when the editor is running and the pull−down menu “File > Activate Sets” is used to bring up the Activate Sets dialog, the Current Sets list will not reflect the changes made by the PMEM Clear. The PMEM Clear causes the board to revert to the original sets. If you want to force the Current Sets list to display the original sets, delete the server file “CurSets.dat.” This file is found in the directory “jupiter\AppData\IOEdit\SetName\” where SetName is the current set that has been selected with the Control Center (this file doesn’t get created until you successfully activate a set). Note that edit sets may span boards and a PMEM Clear on just one board may cause the system to be in a state where the Current Sets list cannot reflect the system.
When a row is selected, Cut will only cut from the Entry, Mnemonic, and Comment columns.
Paste Row does not automatically create a new row. To create a new row, a blank row must first be Inserted and remain selected; then the copied (or cut) row can be pasted into the new row’s position.
Certain columns (Input, Output, PW level, and Category [for input sets]) have drop down lists of valid values for the cells in these columns. You cannot paste invalid values into the cells in these columns.

JNS CP I/O Set Editor


Figure 11−1.
This application replaces the JNIA Force Unlock application. It allows you to unlock or unprotect any outputs that have been locked or protected from anywhere in the system.
The first column lists the name of any outputs that are locked or protected. The second column lists the panel that locked or protected the output. Sometimes, the application is unable to determine which panel was used; in this case, the field may be blank or may contain a number. Columns 2−n are for the levels defined in the Switcher Description table. Each column shows whether a particular output and level are locked or protected.
To unlock or unprotect an output, click anywhere in the first two columns. The entire row will be selected. To deselect a line, simply click in the first two columns again. Click on the Force Unlock button, and the output will be unlocked or unprotected, and the line will eventually be deleted from the display. (Note: If complete status for all levels of an output does not appear you may need to repeat this step to unlock/unprotect all levels.)
To unlock an individual output/level, click on that cell in the table, then click on the Force Unlock button. The cell should be cleared. The line will not be deleted from the table until all levels on that output have been unlocked or unprotected.
Exit - Close the application. Help
About - Display the application’s about box with version information.
File

JNS Force Unlock


Figure 12−1.
The JNS Logger and Log Viewer are used to create, view, and print log files of Jupiter LAN activity. These files can be useful for troubleshooting. The Log Viewer will display Jupiter LAN activity as it occurs and record errors detected by the Jupiter Network Suite. To assure accuracy of the date/time stamp, connecting the CM 4000 to house time code is recommended (for additional information about time code, see page G−11).
The functionality of the JNS Log Viewer is similar to that of the Jupiter Network Interface Application (JNIA) Log Viewer; however, the user interface is very different. (Although the JNS Logger replaces the JNIA Log Viewer, the JNIA Log Viewer is still available on Windows 95 platforms.)
Logger and Log Viewer require installation of the Jupiter Network Suite.
Select “Start > Programs > Jupiter Network Suite > Logger.”


Figure 12−2.
The Logger “Options” pull−down menu allows the operator to select which events to log.

Figure 12−3.
To begin logging, select “Start.” The following dialog box will appear when logging is in progress:

Figure 12−4.
The JNS Log Viewer can display Jupiter LAN activity as it happens, even if the JNS Logger has not been started. However, the JNS Logger must be running in order to capture the events; i.e., have them saved to a file automatically.
JNS Logger

To run the Log Viewer, select “Start > Programs > Jupiter Network Suite > Log Viewer.”

Figure 12−5.
When first started, the Log Viewer is in the Dynamic Data mode, i.e. all displays show Jupiter LAN activity as it happens. Select “View” and select the desired Dynamic Displays.

Figure 12−6.
Dynamic Displays hold up to 256 lines of information.
To view Jupiter LAN activity that has been logged to a file, select “File” and then “Open” the desired log file.
Log files are created in the “logdata” subdirectory of where JNS was installed. By default, JNS is installed in C:\Program Files\Thomson\Jupiter\Jupiter Network Suite and therefore log files would be found in C:\Program Files\Thomson\Jupi- ter\Jupiter Network Suite\logdata.
After opening the file, select “View” and select the desired displays. Note that Dynamic Displays and Static Displays can coexist. The caption of each window indicates if it is a Dynamic Display. If not a Dynamic Display, then the caption indicates which log file the data pertains to. The JNS Log Viewer allows simultaneous displays of multiple log files.
JNS Logger


Figure 12−7.
Sort displays by clicking on the column heading.
To select Dynamic Displays after opening a log file, select “File > Dynamic Data” and then select the desired Dynamic Dis- plays.
Set the Date/Time Filter, (“View > Date/Time Filter”) in order to filter log data. The selected Static Display as well as new Static Displays created after setting the filter will use the filter settings.
To Print or Export a display, select “File > Print” or “File > Export.”
Sometimes, some of the fields in a Log Viewer grid may be truncated. To see the entire field, select “View/Auto−adjust column widths” from the menu. The columns will be automatically resized to fit the largest field in the column.
In some cases, the “All Events” table has an especially large Description field. If you are using a low−resolution screen (like 800x600), you may be unable to make the window large enough to see the entire field. However, you can cut and paste the field or fields into another application (like notepad), where you can see the entire field. You can also export the table to a CSV file, where it can be viewed with applications like Excel.
JNS Logger

Configuration Upload displays all CM 4000s on the LAN that are running Jupiter XPress, displays configuration information about each CM 4000, and allows for the currently active configuration set and the previously active configuration set to be uploaded from any of the CM 4000s.
Whenever a configuration set is successfully compiled, the set is zipped and placed in the Jupiter\Comp directory. When a set is activated on a system that has one or more CM 4000s that are running Jupiter XPress, that zip file is downloaded along with the compiled file.
When the Configuration Upload utility is used to upload the active or previous set, the zip file is sent to the Jupiter\logdata directory on the Jupiter File Server. The Configuration Editor can then be used to unzip the set, edit the set, compile the set, and/or activate the set.

Figure 13−1.


Figure 13−2.
JNS Configuration Upload


Figure 13−3.
Figure 13−4.
After editing and saving your changes, you may need to reboot the CM 4000s in order to see them listed for the multicast scope.
JNS Configuration Upload


Figure 13−5.
JNS Configuration Upload


Figure 14−1.
The JNS Physical Control is a replacement for the Jupiter Physical Control application. It allows the user to switch using “physical” input and output numbers.
Logical levels are displayed on the left in the order that they appear in the Switcher Description table.
To perform a switch, first select a level from the list, then enter the physical output number in the Output field. At this point, you can click on the Update Status button to check the current status of the selected output and level; the status will appear in the Input field. Enter the new input in the Input field, then select Take. The Input field will clear and the Take should occur. To verify, select the Update Status button.

JNS Physical Control

This utility allows the user to see the physical inputs and outputs associated with a logical or physical control panel, input mnemonic, output mnemonic, and level mnemonic. It also provides the user the opportunity to view outputs associated with a logical or physical input.
This utility can be used in conjunction with the Physical Remapping Utility. The user must be logged into the network for this utility to function.
This is an MDI application. An MDI application has a window within which multiple MDI child windows, which are frame windows themselves, can be opened, each containing a separate document (or a log file for this utility).
New − Allows the user to create a new Diagnostic Log File.
Open −Allows the user to open an existing Log File.
Close − Closes the frame window that has the keyboard focus. If only one child frame window is open, this will close that child window.
Save − Saves the log file that is open in the child frame window, which has the keyboard focus.
Save As − Saves the log file to a different filename.
Print − Prints the current log file.
Print Setup − Sets up the printer.
Recent Files − Lists the last four log files being created or opened.
Toolbar − Allows the user to display or hide the toolbar.
File · Exit · View

Status Bar − Allows the user to display or hide the status bar.
Input Mapping − Provides the user with the input mapping table.
Input/Output Exception Table − Provides the user with the Input or Output Exception tables.
Manual − Allows the user to update the log file manually.
Automatically − Allows the user to update the log file automatically.
Cascade − Cascades all non−minimized MDI child windows.
Tile − Tiles all non−minimized MDI child windows.
Displays the About dialog box.
Figure 15−1 shows the main MDI frame window that the user sees when entering the application.

Figure 15−1.
Selecting this item brings up the following dialog:


Figure 15−2.
Select a control panel (MPK device) by clicking on one row of the grid table. The row will be highlighted and the OK button will be enabled. When OK is selected, the following dialog will be displayed:

Figure 15−3.
This dialog displays a filename that consists of the name of the control panel the user has chosen and the current time and date. Select the Change button to change the filename. If OK is selected, a MDI child frame window containing a empty log document will be displayed:
JNS Physical Diagnostics


Figure 15−4.
The title bar of this MDI child window shows the log file name, and the first two fields of the dialog show the control panel the user has chosen. To display the associated physical information, select an output, input and level mnemonic. Once these fields are filled in, select UPDATE to display the “Physical” table.
The Physical table displays the switcher, logical level name, physical inputs and outputs associated with the logical informa- tion. The user may select to update the table and log manually or automatically by selecting the Manual/Automatic toggle in the Options menu. Note that multiple lines of information may be displayed for each event if the currently selected input/ output/level uses path−finding.
The contents of this scrolling display can be saved as a CSV (comma delimited) file by selecting the File > Save menu option.
When the “Output” field is selected from the “Level Set” table, the “Output Select” dialog is displayed:
JNS Physical Diagnostics · Selecting By Output


Figure 15−5.
The title bar of this window displays the Control Panel Output Set name as well as the logical control panel name.
The table displays the output set for the selected control panel. To select an output, click on any row in the table, and click “OK.” The output mnemonic is displayed in the output field of the Level Set table in the Physical Diagnostic child window.
When the “Level” field is selected from the “Level Set” table, the “Level Select” dialog box is displayed:

Figure 15−6.
The title bar of this window displays the Control Panel Level Set name as well as the logical control panel name.
The table displays the level set for the selected control panel. To select a logical level, click on any row in the table, then click “OK.” The level mnemonic is displayed in the Level field of the Level Set table in the Physical Diagnostic child window.
JNS Physical Diagnostics · Selecting By Level

After selecting the panel mnemonics, the UPDATE button of the MDI child window will be enabled to allow the user to up- date the physical information. All events will display in the window with a scroll bar, if necessary. If “path−finding” is in use, there will be multiple lines of data for an event. The data will be written to a comma delimited CSV log file, as displayed in the title bar of the child window. The log file will have the capability of being printed to the currently selected Windows printer. The user may select to update the table and log manually or automatically by selecting the Manual/Automatic toggle in the Options menu.
This menu allows the user to view and print an existing log file. The following Open dialog is displayed to allow the user to choose an existing log file:

Figure 15−7.
After the user selects a file, a MDI child window as in File > New containing the information of all the events in the log file will be displayed.
The View menu contains Input Mapping, Input Exception Table, and Output Exception Table items.
Input Mapping allows the user to view the mapping of Logical Outputs; Physical Outputs can also be viewed by selecting a logical switcher, logical level, and an input, as seen in the following window:


Figure 15−8.
Inputs are selected either by physical number, or logical name. Once all the fields are filled in, the program will then display a list of outputs the input is currently switched to. The information in this table can be printed to the currently selected Win- dows printer.
The Input and Output Exception Tables display the current physical input and output remappings:

Figure 15−9.
These Input or Output exception tables are entered from the Physical Remapping Utility. They can be printed to the currently selected Windows printer.
JNS Physical Diagnostics

JNS Physical Diagnostics

This application allows the user to change individual or ranges of physical inputs and outputs, mapping around failed cross- points or entire crosspoint boards.
This utility can be used in conjunction with the Physical Diagnostics Utility. The user must be logged into the network for this utility to function.

Figure 16−1.
The window above is displayed when the application is started. Select either the Input or Output check button for different I/O type mapping, then select a switcher and level (as defined in the Switcher Description Table). Select either the “Single Port” or the “Whole Board” radio buttons depending on whether individual or ranges of pages are to be changed.
Select Exception Table − Allows creation of a new Input or Output Exception Table or reuse of an existing table.
File

Save Log File − Saves the current log file under the existing name. If the file has not yet been named, the program will default to the Save As option.
Save Log File As − Saves the current log file under a new name.
Page Setup − Sets up the page layout of the printer.
Print Log File − Prints the current log file.
This menu allows selection, on a level by level basis, of the range sizes for the level, and the idle physical inputs and outputs for the level. Range sizes are based on router type and the user is given the opportunity to select numbers from 1 to 64 from a drop−down list.
View − display the Input or Output Exception tables.
Enter the old physical input or output then a new physical input or output. The old physical number is the original number from the switcher input or output table. The user should get this old physical number information from the switcher input or output table, not the Physical Diagnostic utility. However, the user may determine the original physical number by reading the number from the Physical Diagnostic utility, and looking up the number in the Exception tables. The user may view the Input or Output Exception table by clicking on the corresponding entry in the View menu (see below).
The user may type in physical numbers from the edit box. The Original Physical Input/Output edit box contains all the cur- rently used physical numbers on the specified switcher and level. The New Physical Input/Output combo box contains all physical input and output numbers defined as “Idle” in the System Definition Menu for the specified switcher and level. When entering a single number, the screen will update to show him the board range for that specific input or output. The area will be grayed out, indicating it cannot be changed. After typing in the port number, the system will automatically validate the number. If a wrong port number is entered (a number not in the range), the system will display a warning box:

Figure 16−2.
If the user elects to remap a range of numbers by pressing the “Whole Board” radio button, the number he or she enters could be any of the physical numbers in the range. The system will use the number entered in the System Definition Menu for range size per level to determine the actual range and insert the correct range in the window. The first window shows the system if a single number is entered in a range. The second illustration shows a range being entered.
JNS Remapping · Exit · System Definition


Figure 16−3.

Figure 16−4.
A comment field in the main dialog box is available as a word−wrap box for the user to enter relevant comments regarding the remap.
JNS Remapping

When Remap is selected, the system will check to make sure that the old physical number(s) are valid, then it will check to make sure that the new physical number(s) are available by checking the Switcher Description, the Switcher Input or Output tables, and the Input or Output Exception tables.
If the physical numbers are valid, the system will display the following confirmation dialog box:

Figure 16−5.
Select Proceed or Cancel. If you elect to proceed, the information will be saved in the Input or Output Exception tables. These tables serve to map old physical inputs or outputs to new ones. The updated table will then be sent to the VM 3000 controller boards. Changes are effective immediately. If you select cancel, the system returns to the remap window with no changes made to the system or exception tables.
If the physical numbers are already mapped, the program will display a message indicating the inputs or outputs are currently remapped:

Figure 16−6.
You have the option of remapping or keeping the current mapping.
The remap information, including the comment field, date, and time stamp, is written to an ASCII log file, comma delimited CSV file for exporting to a program such as Microsoft Excel. This log file should be named and can be printed to the current Windows printer.
The Restore button removes a mapping from an Exception table and remaps the number to its original number from the Switcher Input or Output table. This new table is then sent to the VM 3000 controller boards. Changes are effective immedi- ately. The user is prompted for confirmation as above prior to any changes taking place.
JNS Remapping

From this menu you can select range sizes, idle inputs, and idle outputs on a level basis. The following dialog box will be presented:

Figure 16−7.
The Switcher Name, Switcher Level, #In and #Out fields are read from the active set’s Switcher Description table and cannot be modified. The range is selected from a drop−down list. Range numbers from one to the minimum of 64 and #In/Out are valid.
To define the input groups available for remapping, or the idle inputs, first select the level; the grayed Idle Inputs/Outputs button will be enabled. Press either the Idle Inputs or Idle Outputs button.

Figure 16−8.
The heading line shows the switcher and level names. Next, define the group by specifying a physical input number and a count. The system will perform error checking to make sure that each input is not part of another group. The system will not check against the size boundaries for that level, as the user may desire to map one input at a time. When OK is selected, all changes are written to a binary file for future use.
JNS Remapping · Setting Idle Inputs/Outputs

Enter both the idle input and output selections at least once. The information entered into the tables will be stored by the system and be displayed each time the application is used. Controls allow editing the tables as needed, but the information will remain persistent.
For efficiency and speed, remappings will be limited to a maximum of 64 inputs and 64 outputs. Display the current Input or Output Exception table by selecting the Input or Output Exception Table item from the View menu. The following dia- logs will be displayed, based on selection.

Figure 16−9.
Information in this table can be printed to the currently selected Windows printer.
To restore old physical numbers and remove them from the table, select rows from the table, then selects the Restore button to remove the selected mappings from the Exception table. The user could also select the Restore All button to restore the whole table. After confirmation from the user, the numbers are remapped to their original numbers from the Switcher Input or Output table. This new table is then sent to the system controllers. Changes are effective immediately.
JNS Remapping


Figure 17−1.
This application allows the user to do simple Takes using any control panel input, output and level set in their currently active set.
When you first open the Router Control Utility, you will see the Configure window. You must select an input, output, and level set. These sets will be used when making switches.

Figure 17−2.
Click on one of each set and then click on OK. The Configure dialog will disappear and the Outputs, Inputs, and Levels lists in the Router Control window will fill with entries from the selected control panel sets. You can return to the Configure dialog by selecting the “Configure” command from the Options menu.

The table at the top of the window displays the status for the currently selected output. Initially, the grid is empty because no output is selected. To display status for an output, select an output from the Outputs list. The name of the output appears in the first column, and status is displayed for each level in the selected level set. If nothing is currently switched to the output in any of the levels, “?” will appear. If the display will not fit across the window, a scroll bar will appear below the table. You can also resize the window to see more levels.
To do a Take, select one input, one output, and one or more levels. To deselect a level, click on it again. Click the Take button. The status display should update accordingly.
Exit - Close the application. Options
Configure − Display the Configuration dialog (see above). Help
About - Display the application’s about box with version information.
JNS Router Control · File


Figure 18−1.
The Router Save/Restore application displays router status (setup) and allows the user to save and restore router status.
When the application is first run, it displays the status for the entire router. Outputs from the Switcher Output table are dis- played in the first column, and level names from the Switcher Description table are displayed along the top row. Input status is displayed in the white cells in the table. These input names come from the Switcher Input table. If an output is locked, the cell will be red and an “L” will be displayed next to the input name; if an output is protected, the lettering in the cell will be red and a “P” will be displayed; if the Take is unconfirmed, the cell will be yellow and and a “U” will be displayed. In the example above, output 100 is locked and output 102 is protected.
Status is displayed dynamically. If you make switches, the Router/Save Restore display is updated immediately.
To save router status, click on the Save command in the File menu. A standard Windows File Dialog will appear. Select the directory where you wish to save the file and enter the name. Click OK. The application will save the current router status to the file. Router Save/Restore files have a .rsv extension by default.
To restore a saved router status, click on “File > Restore.” A standard Windows File Dialog will appear. Locate the file you wish to restore, select it, and click OK. The application will execute takes to restore the saved status.

Note: Because restoration includes lock/protect status, it is possible for the Router Save/Restore application to override and switch a locked or protected output. For example, if an output is not in a lock/protect condition at the time of a save, but is later switched and locked/protected, it will be “force unlocked/unprotected” and switched back to the saved input when status is restored.
Router Save/Restore lets you restrict the outputs and levels that are displayed and saved. To do so, select the “Select Outputs and Levels” command from the Options menu. The following dialog will be displayed:

Figure 18−2.
Select the outputs and levels that you want to display or save. You can click and drag to select contiguous entries. To unselect an entry, click on it again. When you are done, click on OK. Only the selected outputs and levels will be displayed in the Router Save/Restore window. If you save the status, only the displayed outputs and levels will be saved. Selecting outputs and levels does not affect which outputs and levels are restored. The application always restores all outputs and levels that were saved in any .rsv file.
Save - Save router status (see above). Restore - Restore router status (see above). Exit - Close the application. Options
Select Outputs and Levels - see above. Help
About - Display the application’s about box with version information.
JNS Router Save/Restore · File

CM 4000 VGA Status Display
The CM 4000 provides a VGA output for system status display. Basic controls for this display are located on the front panel (Figure A−1).
Figure A−1. VGA controls on CM 4000.
The CM 4000 VGA Status Display can optionally be operated with the CP 3020, a 1 3/4−inch rack mount panel configured as a device type “VC 3020.” (Figure A−2.) To use the VGA display to best advantage, it should also be connected to a dedi- cated CP 3000 Switcher Control Panel (configured as a “VCP 3000”) and an MC 3000 Machine Control Panel (configured as a “VMC 3000”). Grass Valley recommends that all panels be mounted immediately beneath the VGA monitor. These panels can be on different MPK buses, but they must all be connected to the CM 4000 being used to drive the VGA display. See Figure A−3.
MODE
CHNG MODE 0 9 1 2 3 4 5 6 7 8
Figure A−2. CP 3020 with suggested VC 3020 labelling.
Philips WXYZ TELEVISION ROUTER/VTR STATUS PAGE: 00 May 10, 1999 SWITCHER STATUS 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− OUTPUT VIDEO LEFT RIGHT TC −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PrdA VT01 PrdB VC01 VC01 VC01 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1 PrdC Cam1 Cam1 Cam1
Figure A−3. VGA Status Display installation.
VGA cable 25 feet (8 m) max.
Serial data cable (see page 2−63)
MPK bus to optional controls
CM 4000
Sync ref. See
pg. 2−64
CP 3000 Switcher Control Panel
MC 3000 Machine Control Panel
A−1 CM 4000 Installation and Operating Manual
Video Out (VGA) · 10/100baseT Jupiter LAN

SUMMARY OF SOFTWARE CONFIGURATION PROCEDURE
Following hardware installation:
a. A CP 3020 used with the VGA is configured as type “VC 3020” (page 5−114).
b. A CP 3000 used with the VGA is a type “VCP−3000” (page 5−114). If the CP 3000 has an expansion panel, it must be entered as a type “VCP3000E.”
c. An MC 3000 panel must be entered on the MPK Devices table (page 5−114) and given the device type of “VMC−3000” or, if it has an expansion panel, as a type “VMC3000E.”
This table establishes the name of the Page Description file; i.e., the name of the file that will be created when the “Tools > Generate VGA Files” command is run.
The Generate VGA Files command will refer to the information in the current Edit set, then use the factory default for- mats to build two files: the first file will use the name entered on the VGA Status Display Table plus the extension “.vga.” The second file will be created identically to the first but will have the name “vga−desc.vga.” Both files will be written to the \jupiter\config\ configname directory, where configname is the name of the currently selected edit set.
This message is a reminder that the system is about to use the factory default settings when building the Page Description file. (When first installing the VGA, this is OK.)
A−2 CM 4000 Installation and Operating Manual

CUSTOM DISPLAY FORMATTING
This discussion assumes that the reader is familiar with ASCII file editing concepts and that the procedure described on page A−2 has been used to create preliminary VGA display pages based on the factory default layouts.
The VGA status display output of the CM 4000 is designed to give a great deal of flexibility to the user in defining what kind of system information will be displayed at a particular location on the VGA screen. The types of information, or “fields,” that can be displayed are:
Switcher Output Status (any level) Switcher Input Status (any level) Machine Status (Play, Stop, Record, etc.) Machine Delegation Status Machine Linkage Status (Which control panel it’s currently linked to) System Time and Date System Control Board Status (Active, Inactive) System Control Board Time Source (Time Code Reader, File Server, etc.) System Control Board Messages (Also displayed by the logger) Path Finding (Tie Line) Status (details about Tie Line displays are shown on page A−9)
The type and location of these fields are determined by a user−named text file called the “VGA Page Description File.” This file is located in the \jupiter\config\configname directory, where configname is the name of the currently selected edit set. The file is a standard DOS ASCII Text file with “.vga” as its file name extension. The VGA Page Description File can be edited by the end−user in order to modify existing status pages or create new ones.
The following instructions explain how the display fields are positioned, defined, and colorized. After the VGA Page Descrip- tion File is edited, the Edit set must be compiled and downloaded in the normal manner. Be sure to keep copies of known−good VGA Page Description Files (.vga files) in another directory. Once the .vga Page Description File has been customized, the Generate VGA Files command should NOT be used.
Basic Rules:
A−3 CM 4000 Installation and Operating Manual

Field Type Start Char Field Length Definition Syntax −−−−−−−−−− −−−−−−−−−− −−−−−−−−−−−− −−−−−−−−−−−−−−−−− Switcher Name S Not Displayed Sssssssss Output Name O 8 Onoooooooo Level Status (Output) l 9 lnllllllll Input Name I 8 Iniiiiiiii Level Status (Input) l Rest of line lnllllllll −Continued Input Status C Rest of line C Path Finding Status G Rest of line Gngggee System Time i 8 in System Date a 12 an Machine Name M 8 Mnmmmmmmmm Machine TMC Status m 8 mn Machine Delegation d 9 dndddddddd Machine Linkage Status k 8 kn Board Name B 8 Bnbbbbbbbb Board Message g Rest of line gn Board Status u 8 un Board Time Source s 17 sn Screen Text T Variable Tn−−−−−−−−−− Current Page Number p 2 pn Button Number P Not Displayed P#xx
A−4 CM 4000 Installation and Operating Manual
Field Definitions

Definition Syntax Key: VGA Color Color Code −−−−−−−−−−−−−−−−−−−−−− −−−−−−−− −−−−−−−−−− n = Color Code White 0 oooooooo = 8 char System Output Name Yellow 1 iiiiiiii = 8 char System Input Name Magenta 2 llllllll = 8 char System Level Name Red 3 ssssssss = 8 char System Switcher Name Cyan 4 pppp = 4 digit Physical Output Number Green 5 mmmmmmmm = 8 char System Machine Control Device Name Blue 6 dddddddd = 8 char Delegation Group Name Dark White 7 bbbbbbbb = 8 char System Board Name Brown 8 −−−−−−−− = User defined screen text (any length) Dark Blue 9 xx = 2 digit Button Number ggg = 3 digit group number (0−999) ee = 2 digit line number (0−99)
Box Drawing Characters (IBM Line Characters) −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Character Converted to: −−−−−−−− −−−−−−−−−−−−− + Corners of a box, or intersections of vertical and horizontal lines − Horizontal Lines | Vertical Lines
For example, a simple box, divided into four squares inside, would be defined like this:
+−−−−+−−−−+ | +−−−−+−−−−+ | +−−−−+−−−−+
As a quick demonstration of the VGA Page Description File syntax, to display the status of the switcher output “VTR1” of the switcher name “DEFAULT,” on levels “VIDEO,” “LEFT,” and “RIGHT,” the formatting instructions would look like this (assuming “” is substituted with a real character):
SDEFAULT O0VTR1T0 l0VIDEOT0 l0LEFTT0 l0RIGHT
The letters “S,” “O,” “T,” and “l” (small L) define the type of field of the following text. The number “0” after the letters “O,” “T,” and “l” corresponds with the color the data will appear on the screen.
A−5 CM 4000 Installation and Operating Manual

Page Description Examples
These examples assume that the procedure described on page A−2 has been used to create preliminary VGA display pages based on the factory default layouts, and that the .vga file now needs to be customized.
Switcher Output Status Page
P#00 SMAIN T0Thomsonö KXYZ TELEVISION FACILITY CONTROL SYSTEM Page: p0 a0 T1 MAIN Switcher Output Status i0 T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0OUTPUT T6| T0VIDEO LEFT RIGHT T/C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− O5PRDA T6 | l5video l5left l5right l5t/c O5PRDB T6 | O5PRDC T6 |
Thomson KXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 00 May 10, 1999 MAIN Switcher Output Status 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− OUTPUT VIDEO LEFT RIGHT TC −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PrdA VT01 PrdB VC01 VC01 VC01 PrdC Cam1 Cam1 Cam1
Figure A−4. Text file and resulting status page (example)
A−6 CM 4000 Installation and Operating Manual
Inputs · Levels · Outputs

Switcher Input Status Page
P#01 SMAIN T0Thomsonö KXYZ TELEVISION FACILITY CONTROL SYSTEM Page: p0 a0 T1 Switcher Input Status i0 T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0INPUT T6| T0SDV T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0000 T6 | l0SDV T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0001 T6 | T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0002 T6 | T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0003 T6 | T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0004 T6 | T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− I0005 T6 | T6 | C T6−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Thomson KXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 01 May 10, 1999 MAIN Switcher Input Status 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− INPUT SDV −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− VTR5 VT01 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− STUA VC01 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− PrdC Cam1 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Figure A−5. Text file and resulting status page (example)
A−7 CM 4000 Installation and Operating Manual
Levels · Outputs · Inputs

Machine and Delegation Status Page
P#02 T0Thomsonö KXYZ TELEVISION FACILITY CONTROL SYSTEM Page: p0 a0 T1 Machine & Delegation Status i0 T6−−−−−−−−−+−−−−−−−−−+−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0Machine T6| T0 Status T6| T0 Linkage T6| T0Jupiter Saturn T6−−−−−−−−−+−−−−−−−−−+−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− M5VTR1 T6 | m0 T6 | k0 T6| d5Jupiter d5Saturn M5VTR2 T6 | m0 T6 | k0 T6| M5VTR3 T6 | m0 T6 | k0 T6|
Thomson KXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 02 May 10, 1999 Machine & Delegation Status 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− MACHINE STATUS LINKAGE JUPITER SATURN −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− VTR1 PLAY ASSIGNED ASSIGNED VTR2 *OFF* VTR3 *OFF*
Figure A−6. Text file and resulting status page (example)
P#03 T0Thomsonö KXYZ TELEVISION FACILITY CONTROL SYSTEM Page: p0 a0 T1 System Status i0 T6−−−−−−−−+−−−−−−−−+−−−−−−−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0BOARD T6| T0 STATUS T6| T0 TIME SOURCE T6| T0 MESSAGES T6−−−−−−−−+−−−−−−−−+−−−−−−−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− B5CM−Board T6| u5 T6| s5 T6| g0
Thomson KXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 03 May 10, 1999 System Status 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− BOARD STATUS TIME SOURCE MESSAGES −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− CM−board ACTIVE RTC set by server (m−red): This board is ACTIVE−auto Figure A−7. Text file and resulting status page (example)
A−8 CM 4000 Installation and Operating Manual
System Status Page

TIE LINE (PATH FINDING) PAGE
(For a general discussion of path finding, please see page 5−174.)
The VGA tie line display allows the user to determine which sources and destinations are using which tie lines. See Figure A−8.
Group 1 line 0 DVE−1 > Keyer 1 line 1 VTR 2 > Monitor 1 Monitor 4 line 2 VTR 1 > G002 L03 Group 2 line 3 G002 L03 > Monitor 2
Figure A−8. Tie line display.
In path finding, there is a “Group” for each switcher level. The Group number for a given level corresponds to the actual row number in the Pathfinding Description table (page 5−177).
The “line” number is the physical tie line in use.
The input (“DVE−1”) and output (“Keyer 1”) names are the logical names from the Switcher Input table (page 5−48) and Switcher Output table (page 5−55).
Jupiter’s tie line management system can consist of multiple tie line usage. In other words, tie lines using other tie lines to access a source. This state is indicated by displaying the group number and line number of the tie line instead of the input or output number. In Figure A−8, Group 1 line 2 is carrying VTR 1; however this tie line is connected to Group 002 line 03, which in turn is connected to Monitor 2.
If an output for a specific group/line has no tie line source connected to it, the source and destination fields will contain the word “unused.”
The Next key will move the group/line destination field to show the next group of 1 or more destinations. A double arrow (>>) will be displayed on a group/line row if the current row has no room to show other destinations that are switched to a source. The message “No More” will be displayed if no more destinations for a group/line are available. The other keys are not used.
The user must define the Tie Line display page (as described below), entering the desired tie line group numbers and line numbers. The usual limit of 25 rows per page applies.
A−9 CM 4000 Installation and Operating Manual

Tie Line Status Display
P#04 T0Thomsonö KXYZ TELEVISION FACILITY CONTROL SYSTEM Page: p0 a0 T1 VGA Tie Line Status Display i0 T6−−−−−−−−−−−−−+−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0Group No. T6 | T0Line No. T6 | T0SOURCE Destination T6−−−−−−−−−−−−−+−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− T0G#0 VIDEO T6| T0Line0 T6 | G500000 T0 T6 | T0Line1 T6 | G500001 T0 T6 | T0Line2 T6 | G500002
Thomson KXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 04 May 10, 1999 Path Finding Path1 −> Path2 12:34:56 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Group No. Line No. Source Destination −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− G#0 VIDEO Line0 P2018 > P1017 Line1 P2020 > P1018 Line2 Unused > Unused Figure A−9. Text file and resulting status page (example)
A−10 CM 4000 Installation and Operating Manual

CM 4000 Reset
There are four ways to reset this controller:
A . Control Center Go to “Start > Programs > Jupiter Network Suite > JNS Applications > Control Center.” Then select the “Configuration” tab and “Reboot.” This will reset all controllers in the system. Or, select the “Board Info /Control” tab and toggle on the board you want to reset; then click “Reboot” (note that having different versions of software or configuration tables between boards can cause sys- tem instability). For more information about the Control Center, see page 9−1.
B . Press the front−panel Reset button
C . Cycle Power
D . Console port Use of the Console port is described in Appendix C.
During a reset, the CM will test itself and, depending on the result, may request a new download from the file server.
CM 4000
If the reset procedure just described fails to solve the problem, clear the Pmem (parameter memory).
Proceed as follows:
Go to “Start > Programs > Jupiter Network Suite > JNS Applications > Control Center.” Then select the “Board Info /Control” tab and toggle on the board you want to clear; then click “Clear PMEM.” After Pmem has been cleared the boards will be reset automatically. For more information about the Control Center, see page 9−1.
B−1 CM 4000 Installation and Operating Manual

B−2 CM 4000 Installation and Operating Manual
Reset Procedures

Console Port Connections and Protocol
Figure C−1. Location of Console connector.
Figure C−2. Console cable for all controller boards.
The Console connection is provided for test purposes. The protocol for this port is 9600 baud, 8 data bits, 1 stop bit, no parity.
All boards can be reset by momentarily shorting pin 7 to pin 5 on the Console port.
C−1 CM 4000 Installation and Operating Manual

C−2 CM 4000 Installation and Operating Manual
pROBE

Decimal−Hexadecimal−Binary−ASCII Conversion Chart
0 00 00000000 NUL 1 01 00000001 SOH 2 02 00000010 STX 3 03 00000011 ETX 4 04 00000100 EOT 5 05 00000101 ENQ 6 06 00000110 ACK 7 07 00000111 BEL 8 08 00001000 BS 9 09 00001001 HT 10 0A 00001010 LF 11 0B 00001011 VT 12 0C 00001100 FF 13 0D 00001101 CR 14 0E 00001110 SO 15 0F 00001111 SI 16 10 00010000 DLE 17 11 00010001 DC1 18 12 00010010 DC2 19 13 00010011 DC3 20 14 00010100 DC4 21 15 00010101 NAK 22 16 00010110 SYN 23 17 00010111 ETB 24 18 00011000 CAN 25 19 00011001 EM 26 1A 00011010 SUB 27 1B 00011011 ESC 28 1C 00011100 FS 29 1D 00011101 GS 30 1E 00011110 RS 31 1F 00011111 US
32 20 00100000 SP 33 21 00100001 ! 34 22 00100010 ” 35 23 00100011 # 36 24 00100100 $ 37 25 00100101 % 38 26 00100110 & 39 27 00100111 ’ 40 28 00101000 ( 41 29 00101001 ) 42 2A 00101010 * 43 2B 00101011 + 44 2C 00101100 , 45 2D 00101101 − 46 2E 00101110 . 47 2F 00101111 / 48 30 00110000 0 49 31 00110001 1 50 32 00110010 2 51 33 00110011 3 52 34 00110100 4 53 35 00110101 5 54 36 00110110 6 55 37 00110111 7 56 38 00111000 8 57 39 00111001 9 58 3A 00111010 : 59 3B 00111011 ; 60 3C 00111100 < 61 3D 00111101 = 62 3E 00111110 > 63 3F 00111111 ?
64 40 01000000 @ 65 41 01000001 A 66 42 01000010 B 67 43 01000011 C 68 44 01000100 D 69 45 01000101 E 70 46 01000110 F 71 47 01000111 G 72 48 01001000 H 73 49 01001001 I 74 4A 01001010 J 75 4B 01001011 K 76 4C 01001100 L 77 4D 01001101 M 78 4E 01001110 N 79 4F 01001111 O 80 50 01010000 P 81 51 01010001 Q 82 52 01010010 R 83 53 01010011 S 84 54 01010100 T 85 55 01010101 U 86 56 01010110 V 87 57 01010111 W 88 58 01011000 X 89 59 01011001 Y 90 5A 01011010 Z 91 5B 01011011 [ 92 5C 01011100 \ 93 5D 01011101 ] 94 5E 01011110 ^ 95 5F 01011111 _
96 60 01100000 ‘ 97 61 01100001 a 98 62 01100010 b 99 63 01100011 c 100 64 01100100 d 101 65 01100101 e 102 66 01100110 f 103 67 01100111 g 104 68 01101000 h 105 69 01101001 i 106 6A 01101010 j 107 6B 01101011 k 108 6C 01101100 l 109 6D 01101101 m 110 6E 01101110 n 111 6F 01101111 o 112 70 01110000 p 113 71 01110001 q 114 72 01110010 r 115 73 01110011 s 116 74 01110100 t 117 75 01110101 u 118 76 01110110 v 119 77 01110111 w 120 78 01111000 x 121 79 01111001 y 122 7A 01111010 z 123 7B 01111011 { 124 7C 01111100 | 125 7D 01111101 } 126 7E 01111110 ~ 127 7F 01111111 DEL
D−1 CM 4000 Installation and Operating Manual D−1

D−2 CM 4000 Installation and Operating Manual D−2
Decimal−hex−binary chart

Mark/Search Commands in Jupiter Control System
This appendix is to clarify the operation and implementation of these two commands when used with the MC 3000 control panel.
The operation of the MC 3000 control panel is generalized to support time code and non−time code oriented machines. This insures that the operator interface is consistent. Descriptions are included for operation with time code and without.
If the operator presses the MARK push button, the following operations are performed by the MC 3000 control panel driver:
If the operator presses the SEARCH push button, the following operations are performed by the MC 3000 control panel driver:
2) An ES−bus TARGET SEARCH <time value> command is sent to the machine being controlled. The machine is placed in search mode and is moved to the time value included in the TARGET SEARCH command. Since the time value sent to the machine incorporates the preroll time value, the machine will be moved to the PREROLL location. The actual result of this command is determined by the operations of the controlled machine. In most cases, the machine will cue to the previously marked location, this is usually less the PREROLL value.
E−1 CM 4000 Installation and Operating Manual
MARK Command Pushbutton · SEARCH Command Pushbutton

E−2 CM 4000 Installation and Operating Manual
Mark/search Commands

“ESbus” Specifications
Source: EBU tech. 3245−E, Remote−Control Systems for Television Equipment, December, 1984.
FG
RC 6
TC 6
RA
TA
RB 7
TB 7
TB
RB
TA 8
RA 8
TC
RC
FG 9
FG 9
SP
SP
FG Frame ground TA Transmit “A” TB Transmit “B” TC Transmit−signal common RA Receive “A” RB Receive “B” RC Receive−signal common SP Spare
A < B ”MARK” state A > B ”SPACE” state
Figure F−1. Connector pin assignment.
RB B’
1 = HI 0 = LO 1 = HI 0 = LO
A TA
RA A’
C TC
RC C’
Figure F−2. Balanced digi- tal interface circuit.
F−1 CM 4000 Installation and Operating Manual

ESbus command Hex Sony command Hex
STOP 41 STOP 20 00
VAPL 42 VAR FWD 22 12 + speed
VAR REV 22 22 + speed
VFST 45 JOG FWD 22 11 + speed
JOG REV 22 21 + speed
SHUT 46 SHUTTLE FWD 22 13 + speed
SHUTTLE REV 22 23 + speed
PROG. SPEED − 21 39
REDS 48 STANDBY ON 20 05
STANDBY OFF 20 04
SRES 49 SERVO REF SEL 41 33
REMS 4A EDIT PRESET 41 30 + control bits
ENTY 4B EDIT PRESET 41 30 + control bits
(then) REC 20 02
EXIT 4C EDIT PRESET 41 30 + control bits
(then) PLAY 20 01
TASE 4E CUE UP W/DATA 24 31 + data
PRSE 4F CUE UP W/DATA 24 31 + data
PRST (TTON) 60 46 TIMER−1 PRESET 44 00 + data
PRST (PTSV) 60 6D TIME CODE PRES 44 04 + data
F−2 CM 4000 Installation and Operating Manual
ESbus

CM 4000 AccuSwitch Installation and Configuration
The CM 4000 Control Module is presently available for use with the Jupiter XPress or AccuSwitch applications. Note that only one of these applications can be downloaded and executed in a single CM 4000 at one time.
The AccuSwitch product, when connected to and operated by a suitable automation system, allows deterministic switching of a Grass Valley Crosspoint Bus router, with each switch guaranteed to occur one frame after receipt of the automation system switch command; and, allows a sustained switching rate of up to 200 physical crosspoint switches per frame.
CM 4000/AccuSwitch supported functions
Automation interface JNS reboot, JNS clearpmem, activating a configuration from the JNS Control Center, JNS Router Control, JNS RouterSaveRestore Basic switching from JNS Control Panel Suite (GUI control panel)
CM 4000/AccuSwitch non−supported functions
JNS functions except those listed above (for a list of JNS functions, see page 4−1) Hardware control panels MI 3040 General Purpose / Tally Interfaces VTRs and other production machines Third−party routers Pathfinding, remote (non−Crosspoint Bus) routers, distributed routing, 3−stage routers, follow switching VGA status display
The AccuSwitch product follows SMPTE time code and assumes that all switch commands received from the automation system are to be executed within the next 24 hours. Therefore the automation system must send switching commands no more than 24 hours in advance.
As an option, a second CM 4000 can be connected using the BOP 4000 Redundancy Cable Kit and Breakout Panel and oper- ated as a backup unit. For more information, see page 2−8.
The preferred time source for the CM 4000 is house SMPTE time code. Various other devices can be configured as backup sources, but priority is always given to the SMPTE time code input. (The CM will run without time code, but not frame accu- rately.) For more information, see page G−12.
Grass Valley recommends using automation systems which have been tested with AccuSwitch software. Currently supported systems are:
G−1 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
Thomson Broadcast Automation Harris (Louth) Automation Encoda Systems (formerly Columbine JDS/Enterprise Systems)
It is anticipated that additional automation systems will be qualified in the near future for control of the CM 4000 module. For more information, please contact Grass Valley.
Depending on the particular application, a media converter or hub may be needed to connect the Jupiter file server LAN card to the CM 4000 or to a Jupiter VM/SI 3000. The CM 4000 has a 10/100baseT rear panel connector; the VM/SI 3000 has a 10base2 (BNC) rear panel connector.

For cabling details, please refer to the drawings starting on page 2−89.
G−2 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
In AccuSwitch applications, the CM 4000 can be on the same Jupiter LAN as VM/SI 3000 units and Saturn processors. The 10Base2 LAN used to connect VM/SI 3000 and Saturn units is the Ethernet thin cable type, also referred to as “thin net.” LAN cabling guidelines are shown on pages G−4 and G−5. Please note the following additional restrictions:
The following RG−58 thin net cables, with installed BNC connectors, are available from Grass Valley:
1 meter (3.3 ft) 2 meters (6.6 ft) 4 meters (13.1 ft) 8 meters (26.2 ft) 16 meters (52.5 ft) 32 meters (105 ft)
For ordering information, see page 1−22.
The jacket material for these cables is fluoropolymer (FEP).
A termination kit, consisting of a pair of 50−ohm terminators (without ground wire connections) is also available. The part number is 44−039807−001.
G−3 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
ÎÎ

ÎÎ Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ Î
BNC T with insulating cover must be directly on panel
5 16.4 10 32.8 15 49.2 20 65.6 25 82
G−4 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
Figure G−4.10Base2 LAN cable linearity.

ÎÎ ÎÎ ÎÎ Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ ÎÎ Î Î
ÎÎÎ ÎÎÎ ÎÎÎ Î ÎÎ
ÎÎ ÎÎ ÎÎ Î ÎÎ ÎÎ
ÎÎ ÎÎ ÎÎ Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ ÎÎ Î Î
ÎÎÎ ÎÎÎ ÎÎÎ
ÎÎ ÎÎ Î ÎÎ Î ÎÎ ÎÎ Î ÎÎ ÎÎ Î Î
ÎÎÎ ÎÎÎ ÎÎÎ
G−5 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
Figure G−5. ThinLAN insulating cover for tee connector.
Grass Valley part no: 05−042549−001. Amphenol part no: 31−5271. HP part no: 92227R.
G−6 CM 4000 Installation and Operating Manual
Velcro

CM 4000 / AccuSwitch
Software Installation is described in the Field Engineering Bulletin supplied with the software package.
For AccuSwitch applications, the CM 4000 must be configured using the Network Description, Serial Devices, Switcher De- scription, and MPK tables as described below. There are also two new tables that apply specifically to the CM: Time Standard and Video Reference.

Figure G−6. Example Network Description table.
In a redundant CM system, the redundancy cable between the units is marked “Master” on one end; whichever CM is connected to this end of the cable is always the master unit. The hardware address of the master is entered in the “Ad- dress” column. The hardware address of the redundant (“slave”) unit is entered in the “Redundant Address” column. For more information about redundant installations, see page 2−8.


Figure G−7. Example Serial Protocol table.
G−7 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
The CM serial protocol selections are:
ESW (a.k.a. “Jupiter ESswitch protocol”). This is a simplified version of the ES Tributary protocol. It is described in Grass Valley document “ESswitch Serial Routing Switcher Control Protocol, En- hanced Version.” (The protocol description used as a reference should be dated June 2001 or later.)
CET (ES Tributary) protocol, a.k.a. “CM_ESTR.” This is the full tributary ESBus automation proto- col, compliant with SMPTE EG 29−1993, and all associated normative references. The protocol sup- ports all standard bit rates from 300 to 115.2 kBPS. Flow control is an advantage with this protocol.
ASC (ASCII) (a.k.a. “Jupiter ASCII Interface Protocol”). This protocol is described in Appendix N (the protocol description used as a reference should be dated June 2001 or later). If this protocol is used, the developer should read “A note concerning level numbering and external control computers using ASCII protocol” on page 5−60.
If there is a redundant CM, it is not necessary to define it on this table.
Each logical level number of the switcher is given a user−specified name up to eight characters in length, and the system is provided with detailed information about each level. The name of the CM 4000 connected to the switcher is entered in the “M Board” column.
At least one switcher level must be assigned to the CM 4000.
Switcher VI RV Board #In #Out PLvL Follow Level Driver 3 LI 3 LO Option Audio Level DM 400 MC Off Time
MAINROUT CM1 64 64 1 Binary None
2 MAINROUT CM1 64 64 2 Binary Left
3 MAINROUT CM1 64 64 6 Binary Right
Figure G−8. Example Switcher Description table.
The name of the CM 4000 (as per the Network Description table) is entered in the “M Board” column.
Control devices connected to the CM 4000 are entered on this table. (Although an automation system is not an actual “MPK” device, it must still be entered on this table.)
G−8 CM 4000 Installation and Operating Manual
Switcher Description

CM 4000 / AccuSwitch
a. Jupiter ESswitch protocol (ESW) and Jupiter ASCII Interface protocol entries.

Board Input Sets Output Sets Level Set Overide Set Sequence Set In Panel Out Panel Type
Figure G−9.
The Address field should be left blank.
The Input, Output, and Level sets named on this table should include all inputs, outputs, and levels that will be controlled by the external control computer. As a precaution, you may wish to restrict computer control to selected outputs.
The Input and Output sets must be created specifically for use by “serial” devices. The Level Set must be created as a type “CP−3000.” For more information about these sets see page 5−58.
b. SMPTE ES LAN protocol entries.
Type Board Input Sets Output Sets Level Set Overide Set Sequence Set In Panel Out Panel
AUTOIN AUTOOUT AUTOLEV
Figure G−10.
The SMPTE ES LAN protocol defined here is compliant with SMPTE EG 30−1995 and all associated normative references.
The Address field should contain the number “1.”
The Input, Output, and Level sets named on this table should include all inputs, outputs, and levels that will be controlled by the external control computer. As a precaution, you may wish to restrict computer control to selected outputs.
The Input and Output sets must be created specifically for use by “serial” devices.
The Level Set must be created as a type “CP−3000.”
c. SMPTE ES Tributary (CET / CM_ESTR) protocol entries.
As described in the SMPTE specification, ES−Tributary is an addressable serial protocol that allows several serial devices to be individually controlled on a single serial connection of an automation control system. One applica- tion might be to control multiple CM 4000 ports from a single serial connection to an automation system:
G−9 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
Figure G−11.
CM 4000 Control Module
Because each device on the serial connection must have a unique address, entries are made in the MPK Devices Table to associate the serial port numbers to the ES−Tributary address of the CM port. Also assigned in this table are the input, output and level sets associated with router levels to be controlled on that port:
Input Sets Output Sets Level Set Overide Set Sequence Set Devices word In Panel Out Panel
AUTOMAT
ES−TRIB
CM1
IN OUT LEV
2 AUTOMAT ES−TRIB CM1 8 8282 IN OUT LEV
Figure G−12.
Dev Name: This is the device name to be assigned to the controlling device on the port. It is an alpha−numeric name up to 8 characters long.
Dev Type: This is set to ES−TRIB.
Board: Enter the board name of the CM 4000(s) being configured. This name must be identical to the name entered into the Network Description Table.
Port: Enter the port number of the serial port that was configured for the ES−Tributary protocol.
Address: For each port on a given serial line, a unique hex address must be assigned. The address must be an even hex value between 8280 and 828E.
Input Set: Enter the name of the desired input set created in the CP Input Set Table. The set that is created must be specifically for use by serial devices. The CP Input Set defines the inputs that can be controlled on this port. This is a required entry.
Out Set: Enter the name of the desired output set created in the CP Output Set Table. The set that is created must be specifically for use by serial devices. The CP Output Set defines the outputs that can be controlled on this port. This is a required entry.
Lev Set: Enter the name of the desired level set created in the CP Output Set Table. The set that is created must be specifically for use by serial devices. The CP Level Set defines the levels that can be controlled on this port. This is a required entry.
G−10 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
For deterministic switching, time information (hour:min:sec:frame) must be provided to the CM, the preferred time source being house SMPTE time code. This table is used to identify one or more backup time sources for use if the time code source fails. Each CM in the system must be described (except only one entry is required for a redundant pair). Certain fields must be filled in for all systems; see description below.
Address TCR Host Address TCR Host Address TCR Host Address RTC Host Address
Offset from GMT (+/−HH:MM) Time Zone Name
Day (1−31) DST Start Month (MMM)
USA_East −05:00
02AM
DST End Month (MMM)
OCT Figure G−13. Example Time Standard table.
Board − select the name of the CM 4000 board as entered on the Network Description table.
NTP Host / Address − if a Network Time Protocol host computer will be used to supply time information (or used as a backup source), create a host name (if one is desired). As a minimum, an IP address must be entered if an NTP host will be used.
TCR Host / Address − if there is more than one CM in the system where one CM is connected to a time source and acts as a “Time Code Reader” host for the other. If this is the case, enter the name of the host CM as found on the Network Description table. Enter the IP address of the host CM (the IP address can be determined using the JNS Board Status menu).
RTC Host / Address − if a Real Time Clock host computer will be used to supply time information, create the host name and enter the IP address.
Time Zone Name − create a description of the local time zone (up to eight characters).
Offset from GMT − (entry required) Hours and minutes offset from Greenwich Mean Time (Coordinated Universal Time or “UTC”).
DST Start Month / Day / Hour − (entry required) Daylight Savings start date and time. DST End Month / Day / Hour − (entry required) Daylight Savings stop date and time.
If there is more than one time source for the CM, the sources will be prioritized as follows:
G−11 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
For example, if the SMPTE time code source were to fail the CM would attempt switch to the SNTP source; if that source was not available then the CM hardware clock would be used, etc.
For a more technical discussion of CM time keeping, see page G−12.
Sync Standard Sync Standard Horizontal Line
Figure G−14. Example Video Reference table.
Sync Standard − choices are NTSC, PAL, 1080i 60Hz, 1080i 50Hz, and 1080i 59.94Hz.
Horizontal line − this entry determines the switch point.
NTSC choices are 9.5, 10, 10.5, 11, 11.5, 12, 12.5, and 13. The SMPTE recommended setting is 10.5.
PAL choices are 5.5, 6, 6.5, 7, 7.5, 8, and 8.5. The recommended setting is 6.5.
AccuSwitch tracks two time lines, SMPTE time code and an internal real−time clock (RTC).
Time code is used for short−term, frame−accurate switching. Since NTSC video signals run at 29.97 frames per second, drop− frame time code accumulates an error of 2.2610 frames per day. This amounts to +75.442 milliseconds of drift every 24 hours, a discrepancy larger than two seconds every month.
The real−time clock is used to accurately track time long term. This clock is synchronized with other sources based on the entries in the Time Standard table.
If time code is present, the real−time clock’s hours, minutes, and seconds will be synchronized to it. If time code is not present, the SMPTE time line will be synchronized with the real−time clock (i.e., the real−time clock is a backup time line). However, AccuSwitch inhibits adjustments to the SMPTE time line when the system is under a load (i.e., the time line will only be ad- justed when nothing is happening).
When a valid time code is not present, the real−time clock will use SNTP1 to synchronize with the specified sources in the following order:
1 Simple Network Time Protocol
G−12 CM 4000 Installation and Operating Manual
Video Reference · Sync Standard

CM 4000 / AccuSwitch
The idea is to synchronize first with another CM 4000 connected to a time code reader. This would keep the time within a few milliseconds of time code.
If the TCR host does not respond, it will synchronize with a designated NTP server (some PC set up to perform that function). If the house time code went bad, all CM 4000s could stay synchronized with a designated time server, which could itself be synchronized to an accurate national standard.
Finally, if the first two hosts do not respond, a CM 4000 could be selected as the master and all CM 4000s synchronized to it. While this would still allow time to drift it would force all CM 4000s to drift together.
In the final analysis, each time host is just an IP address and the CM 4000 will attempt to synchronize with each one in the priority specified. Any valid IP address can be placed in each of the fields or each can be left empty (no synchronization). Each facility is free to use this feature as it sees fit.
The “Time Zone Name” field is not used. It will accept any string eight characters or shorter.
The offset from GMT must be supplied so that the correct time is displayed. Time in the CM 4000 is always kept in UTC2
internally. When time is displayed, it is shifted according the offset for the local time zone.
For daylight savings time, enter the month, day, and hour to start and stop. Currently if you do not want to adjust for daylight savings, you must enter the same month, day, and hour for start and stop times.
Please refer to Appendix R.
2 Universal Time Coordinated, same as Greenwich Mean Time (GMT)
G−13 CM 4000 Installation and Operating Manual

CM 4000 / AccuSwitch
G−14 CM 4000 Installation and Operating Manual

JupiterXPress Configuration Swap Option
The Configuration Swap option allows JupiterXPress systems to swap between two similar configurations without a Jupiter file server present. Similar configurations means the same number of boards in the network description table, number and type of control panels in the MPK description table, the same switcher description tables, and the same num- ber of inputs and outputs in the switcher input and output tables. In general, changes to the configuration that require PMEM to be cleared should be avoided. The Jupiter Configurator help and warning messages should be used as a guide. Using the CM VGA Options table (Jupiter Configurator > Jupiter > CM VGA Options), Configuration Swapping, PMEM Clear, Local Reboot, and Global Reboot can be made available to the System Command Page (CM VGA Options screen).
Configuration Swapping - when selected swaps between the current and previous configurations and then re- boots, which activates the new configuration. PMEM Clear - clears PMEM in the whole system. Local Reboot - reboots only the board where it is selected. Global Reboot - reboots the whole system. User−Defined Options - currently not used.
After saving, compiling, and activating the new configuration, the System Command Page can be enabled by pressing and holding the NEXT button, pressing and releasing the UP button, followed by releasing the NEXT button. Configura- tion information consisting of configuration name and a date time string (Xpress−1−Fri Mar 15 15:51:03 2003) from each board in the system will then be displayed. Commands are selected using the SELECT, UP, and DOWN buttons. The first SELECT button press will enter selection mode highlighting the first command, which is Exit. The second SELECT button press will activate that command. Pressing the UP or DOWN buttons, once in selection mode, will highlight each selected command.
Requirements for this feature are as follows.
CM 4000(s) running JupiterXpress. Software key enabling configuration swapping. VGA running on at least one JupiterXpress board. CM VGA Options table configured with desired options. Two configurations downloaded to the JupiterXpress system with configuration swap options configured. All boards in both system configurations must be fully operational. The Jupiter file server should not be running any JNS applications.
When JupiterXPress is installed, the Software Key must contain the option for configuration swap. Two configurations with minimal changes (control panel sets, mnemonic names) are downloaded to the JupiterXPress board.
H−1 CM 4000 Installation and Operating Manual


Figure H−1.

Figure H−2.
H−2 CM 4000 Installation and Operating Manual
Configuration Swap

Thomson Jupiter Configuration Set : Xpress−1 Page: 00 03/07/03 System Command Page 19:42:28 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− BOARD | Current Configuration | Previous Configuration.. −−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− CM−Board |Xpress−1−Fri Mar 07 10:28:16 2003|Xpress−2−Fri Mar 07 09:35:16 2003 CM−Board-R|Xpress−1−Fri Mar 07 10:28:16 2003|Xpress−2−Fri Mar 07 09:35:16 2003 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Press then or to Highlight, to Choose −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Exit Swap Configuration Clear PMEM Reboot Local Reboot Global −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Thomson Jupiter Configuration Set : Xpress−2 Page: 00 03/07/03 System Command Page 20:02:18 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− BOARD | Current Configuration | Previous Configuration.. −−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− CM−Board |Xpress−2−Fri Mar 07 09:35:16 2003|Xpress−1−Fri Mar 07 10:28:16 2003 CM−Board-R|Xpress−2−Fri Mar 07 09:35:16 2003|Xpress−1−Fri Mar 07 10:28:16 2003 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Press then or to Highlight, to Choose −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Exit Swap Configuration Clear PMEM Reboot Local Reboot Global −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
H−3 CM 4000 Installation and Operating Manual
Configuration Swap

Thomson Jupiter Configuration Set : Xpress−1 Page: 00 03/07/03 System Command Page 20:10:34 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− BOARD | Current Configuration | Previous Configuration.. −−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−+−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− CM−Board |Xpress−1−Fri Mar 07 10:28:16 2003|Xpress−2−Fri Mar 07 09:35:16 2003 CM−Board-R|Xpress−1−Fri Mar 07 10:28:16 2003|Xpress−2−Fri Mar 07 09:35:16 2003 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Press then or to Highlight, to Choose −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− Exit Swap Configuration Clear PMEM Reboot Local Reboot Global −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− 20. Press and release the SELECT button, which will highlight Exit.
H−4 CM 4000 Installation and Operating Manual
Configuration Swap

Jupiter Remote PC
“Remote” PC configurations allow a user to operate certain JNS applications/tools from a workstation other than the file serv- er. For example, the Software Control Panel Suite (GUI) could be executed, displayed, and controlled at a Remote computer.
Remote applications/tools. JNS programs that can be operated at a Remote PC are:
Board Status Control Center Force Unlock Logger and LogViewer Party Line Download Physical Control Router Control Utility Router Save/Restore Saturn Monitor Follow & Preview Software Control Panel Suite (GUI control panel)
Local−only applications. In contrast, the following programs cannot be operated at a Remote PC: Configuration Editor, CP I/O Editor, Physical Remapping, and Physical Diagnostics. These programs execute in, and are accessible only at, the File Server.
General considerations
I−1 CM 4000 Installation and Operating Manual

As shown in Figure I−1, a Remote PC can be installed on the Jupiter network, or on a separate network (e.g., the facility/IT LAN) connected through a second network interface card (NIC) in the File Server.
If you do connect the File Server to a second network, make sure the two networks are logically separated on separate subnets. In other words, the devices on the Jupiter network will have IP addresses in one number series and the devices on the facility/IT network will have IP addresses in another series. For example, the devices on the Jupiter network will typically have IP ad- dresses in the 192.168.253.x series, while the devices on the facility/IT network might have IP addresses in a range such as 192.168.1.x. In these examples, the subnet mask would be 255.255.255.0 for both class C networks.
Facility LAN Jupiter LAN
Figure I−1.
I−2 CM 4000 Installation and Operating Manual

Software installation is described in the Field Engineering Bulletin supplied with the software. The following is supplemental information.

Figure I−2.
I−3 CM 4000 Installation and Operating Manual
Remote PC

The JNS server applets allow the various JNS applications (such as the JNS Control Center) to send and receive data to and from the File Server and the system controllers.

Figure I−3.
I−4 CM 4000 Installation and Operating Manual
Remote PC

File server − backup PC
As a means of protecting the Jupiter system from File Server failure, a second PC can be installed on the Jupiter network using the “File Server” option (which causes all software to be installed, including Local−Only Applications shown on page I−1). A copy of the current Jupiter Configuration set should also be installed by the user and kept current. Following installation, the PC is normally operated as a Remote unit. Should the main File Server fail, the Remote PC can be reconfigured using “Configure > File Server” and thus placed on line as the new server.
In systems with a very large number of Remote PCs, system performance may sometimes be improved by distributing the Jupiter applications among the PCs, thus reducing loading on the File Server. This is the purpose of the “Configuration > Remote PC” option (as opposed to the “Extended” option). When this configuration is selected, some of the “server applets” will execute in the Remote PC while others will execute in the File Server. (The JNS applications/tools/utilities will always execute in the local PC.) However, it should be noted that newer, high−speed CPUs have largely eliminated the need for load sharing.
If the File Server is running Windows XP and you would like to run remote clients that connect to the File Server, a Local Security Policy setting may need to be changed. By default, Windows XP will prevent remote clients from connecting.
Open the Control Panel, select Performance and Maintenance, select Administrative Tools, select Local Security Policy, double−click on Local Policies in the tree−view, and double−click on Security Options in the tree−view. Scroll down the list of settings to find “Network access: Sharing and security model for local accounts.” Change the setting from “Guest only − local users authenticate as Guest” to “Classic − local users authenticate as themselves.” You may need to reboot the File Server. If you still get DCOM errors while connecting, the Administrative Tools /Event Viewer may provide helpful information.
Keep in mind that the username AND password on both the File Server and the Remote clients must be identical. To prevent unauthorized access, Grass Valley recommends that you use a secure password.
I−5 CM 4000 Installation and Operating Manual
Remote PC · Load sharing

I−6 CM 4000 Installation and Operating Manual
Remote PC

CP 3000 Control Panel Basic Operation
The CP 3000† is a full−matrix control panel, designed to route any source to any destination. (However, access to certain destinations may be limited by the system administrator.)
Looking at Figure J−1, we’ll break the panel up into a couple of groups. The first area is the display window. The top row in the display window shows you the status of each level in the router for a particular destination.
Using the CLEAR key, the bottom row can be toggled between the first page of input override selections (as shown in Figure J−1) and the name of the current output (Figure J−2).
To the right of the control panel is a keypad; this includes all the numbered and lettered buttons. Directly beneath the keypad is a row of buttons that have designated functions.
1 CG
2 NET
3 SAT
A
VTR1 VT1L VT1R VT1T BLK BARS TONE SLNC
EJ VCR
4 CAM
5 REM
B
Status for 4 levels
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
TAKE CHOP LOCK PROT
MORE CLR MENU LEV
Figure J−1. CP 3000 Switcher control panel with example Status/Override display.
Figure J−2. Press CLEAR to toggle to Status/Output display
† For complete CP 3000 operating instructions, see page 6−7.
J−1 CM 4000 Installation and Operating Manual
Overrides

CP 3000 Basic Operation
Aud Ch1 TC Aud Ch2
1 CG
2 NET
3 SAT
A
VTR1 VT1L VT1R VT1T BLK BARS TONE SLNC
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
MORE CLR MENU LEV
TAKE CHOP LOCK PROT
Figure J−3.
Looking at Figure J−3, the display window shows the home menu. This includes, in the top row, the status of the video, audio channel 1, audio channel 2, and timecode levels. In the bottom row, it displays the override selections. These overrides are selected when you push the function button directly below it. This gives you a one button push in conjunction with the TAKE button to call up whatever source is in the display column. For example, pressing F1 and then pressing the TAKE button would select black as the source to the destination the panel is controlling. Another way of selecting a source is to use the keypad and then the TAKE button. For example, pressing VTR and then 1 and then the TAKE button would select all levels of VTR1 as the source.
Since this panel can access any destination (for example, an input to a VTR), you must select the destination that the panel is controlling. This panel can only control one destination at a time. To select or change the panel’s destination, you press the MENU button. Once this button has been pressed, it will change the bottom row of the display (See Figure J−4).
Figure J−4. Page 1 of menu display.
F1 = Status − display output status F2 = Sequence − select input sequences F3 = Audio − audio modes F4 = Output − display/change output
J−2 CM 4000 Installation and Operating Manual
Vid

CP 3000 Basic Operation
By depressing the MORE button, you will call up page 2 of the menu. The function buttons change to represent the following:
Figure J−5. Page 2 of menu display.
F1 = Diagnostics − control panel diagnostics F2 = Define − re−define input overrides F3 = Passwords F4 = Logout
By depressing the MORE button, you will call up page 3 of the menu:
Figure J−6. Page 2 of menu display.
F1 = ID − display control panel device address
By pressing the MORE button again, you will toggle back to page 1 of the menu.
For the present time, we want to go to page 1 and press the F4 button; this will allow us to change what destination the panel is controlling. The bottom display row will now show PANEL OUTPUT = VTR2. (See Figure J−7.)
Figure J−7.
Now any selection made from the keypad area of the controller will change the panel’s destination. For example, with “PAN- EL OUTPUT =” showing, pressing the VTR button, the 2 button, and the TAKE button, you have now selected the panel to control what feeds VTR2. Be aware, however, any time the bottom row of the display shows “PANEL OUT =”, anything you press on the keypad and then press TAKE will change the destination of the panel.
J−3 CM 4000 Installation and Operating Manual

CP 3000 Basic Operation
Let’s try a simple switch. For example, let’s put VTR1 into VTR2. The first thing you would do when you walk up to a panel is find out what destination the panel is controlling. To do this, you would look for the “CURRENT OUT = ” message; if you don’t see it, press CLR until you do.
If you are happy with the output being controlled, we can now change the source feeding our machine. Going to the keypad, press VTR, 1, and then the TAKE button. You have now called up VTR1 into your machine. You will notice the top row in the display window will show VTR1 for the video level and both audio levels.
Another way of calling up a source is to use the override buttons. The bottom row of the display window in the home menu describes which override each function button represents. By pressing the F2 button and then the TAKE button, you will have sent BARS into VTR2.
1 CG
2 NET
3 SAT
A
VTR1 VT1L VT1R VT1T LOCK PRESS TAKE
EJ VCR
4 CAM
5 REM
B
FILM
7 PTCH
8 STU
9 FS
AUX TEST
0 MISC SS
D
F4 F3 F2 F1
TAKE CHOP LOCK PROT
MORE CLR MENU LEV
Figure J−8.
Figure J−9.
J−4 CM 4000 Installation and Operating Manual
Lock symbol

CP 3000 Basic Operation
Now that we have routed something to a machine, we don’t want someone from another panel changing or accessing into that machine. So how do we take care of this problem? From the home menu, if you press the LOCK button you will see the display shown in Figure J−8; by pressing the TAKE button, you will have locked out that destination so that no other source can be switched into it from anyone else’s panel—or even your panel. You will notice that a flashing L will appear at the very left hand top corner of the display.
If you wish to unlock it, you must go to the panel that locked it, call up the destination that is locked, and then press the LOCK and then the TAKE button from the home menu. To find out which panel has something locked, press the LOCK and then the TAKE button. For a moment, the panel will display in the bottom row which panel has it locked out. For example, it will read LOCKED BY MON1. This is telling you that the monitor 1 panel has locked out this destination. Remember that any panel can lock out any destination. By locking out a destination, it must be unlocked before switching even from its own panel.
If you wish to switch from your own panel but protect the output from other panels, then you can use the PROT button. The protect function is toggled on and off exactly like the lock function using the PROT button.
[Grass Valley would like to thank Mr. Howard Lukk for help in preparing this tutorial.]
J−5 CM 4000 Installation and Operating Manual

CP 3000 Basic Operation
J−6 CM 4000 Installation and Operating Manual

Preparing and activating a replacement CM 4000
As discussed on page 2−8, CM 4000s can be installed as a redundant pair, so that failure of one unit will result in control being taken by the second. A third unit can be kept in reserve and, in the event of a failure, have its address altered and be installed to provide a quick replacement for the failed unit and restore system redundancy. See Figure K−1.

Figure K−1. A CM can be kept in reserve, ready to swap with a failed unit.
K−1 CM 4000 Installation and Operating Manual
![Page 624 of the 3Com CM 4000 user manual — [VxWorks Boot]: N [ENTER]](/cdn/reader/bb/bb95f49739aea1e5b5d629b2ae4814a7cc290cbaf11b6b8492d4208a28c906c3/images/page-624.webp?w=400)
A fault condition should be indicated by a “00,” “01,” or “FF” indication on the front panel LED display, or, in the case of a failed power supply, no lamps illuminated. Control should have switched to the other CM by this point. Check that it has by looking for the green Activate lamp. Then proceed as follows:
UP NEXT SELECT
Figure K−2. Activate
The physical Ethernet address is stored in a serial EEPROM chip. The data in this chip is validated with two checksums. If either checksum is invalid, the Ethernet chip will fail to initialize and will not function. Be- cause of this, it is very important that during the EEPROM write procedure, the CM 4000 is not reset or power interrupted until the write cycle is completed.
a. On the replacement CM, connect a terminal to the front console port and power up the unit. It is stressed that this procedure is done with the replacement CM 4000 out of the system where there can be no address conflict.
b. Stop the boot process at the ‘Press any key to stop auto−boot.’ prompt.
c. At the VxWorks boot prompt, enter ‘N’ and then press ‘enter’.
d. Wait for the EEPROM memory to get read:
Reading EEPROM
K−2 CM 4000 Installation and Operating Manual
Replacement CM 4000 · button
![Page 625 of the 3Com CM 4000 user manual — New Ethernet Address is: 00:40:53:21:34:65 [VxWorks Boot]:](/cdn/reader/bb/bb95f49739aea1e5b5d629b2ae4814a7cc290cbaf11b6b8492d4208a28c906c3/images/page-625.webp?w=400)
The current Ethernet address will be displayed:
The first 3 bytes of the Ethernet address are the manufacturer’s ID and cannot be changed. The fourth byte will be shown with an option to change it:
e. Modify the last 3 bytes to match those of the failed CM 4000.
Enter the new digits and press Enter to change Byte 4 or press Enter alone to keep the current byte. In this example, the 4th byte is changed to “21.”
Repeat the process for the remaining two bytes. In this example, the 5th byte will be kept the same, and the 6th
byte changed to ”65”:
f. The EEPROM will now be re−written. During this time, do not reset the CM 4000 or allow the power to reset.
Writing EEPROM
When the write cycle is complete, the new current Ethernet address will be displayed with the vxWorks prompt:
Make a note of this number (e.g., by writing it on the CM back panel).
g. Remove power from the CM 4000.
The replacement CM 4000 will boot up automatically. The other CM 4000 should remain active throughout this opera- tion.
Ensure that the status of all crosspoints on the switcher is reported on the panel.
K−3 CM 4000 Installation and Operating Manual
Replacement CM 4000

a. Go to “JNS Applications > Control Center > Bootp” and check that the correct MAC address is being used for the replacement CM. Also go to the “TFTP Status” tab and look for an indication that the “transfer succeeded” (“100% complete”). If these indications are correct, proceed as follows:
b. Swap control to the replacement CM 4000 by pressing the Activate button.
c. Confirm system operation.
d. Assuming all is well leave the replacement CM 4000 in control of the system. The installation is now complete.
Should problems be experienced return control immediately to the opposite CM 4000. De−power the replacement CM 4000, check all cabling, and reapply power. Should this fail to eliminate the fault, it may be necessary to download a new configura- tion set; refer to “Validating, Compiling, and Activating (Downloading) a Configuration Set” on page 5−13.
If problems persist, contact Grass Valley Technical Support.
K−4 CM 4000 Installation and Operating Manual
Replacement CM 4000

Special Configuration Requirements: Venus DM 400/400A Data Matrix Switching
The Jupiter system can be used to control RS−232, RS−422, and RS−423 data switchers.
DM 400/400A data switchers employ a “reverse” switching technique, where one level is used to switch data from a control- ling device (such as an editor) to a controlled device (such as a VTR); a second level is used to return data to the controller. The return path is switched automatically by the control system.
The following discussion applies specifically to a Venus DM 400/400A data matrix switchers in an RS−422 machine control application; however, the same concepts generally apply to other Grass Valley Crosspoint Bus data switchers and protocols. An important difference is that the Venus DM 400/400A data matrix switcher uses the same physical level number for both the forward and reverse levels; whereas the TVS/TAS series data matrix switchers use different physical level numbers.
For complete information regarding jumper settings and cabling, refer to the technical manual supplied with the switcher. An example of an RS−422 Venus system is shown on page L−2.
§ Type and model of switcher card is shown on front edge of printed circuit board.
L−1 CM 4000 Installation and Operating Manual


Figure L−1. Example of DM 400/400A Data switching system.
Figure L−2. Pinouts for system shown in Figure L−1 .
† VCR pinouts may vary. Check VCR manual =
L−2 CM 4000 Installation and Operating Manual
Venus DM 400/400A

An example of a Switcher Description table for a DM 400/400A data matrix switcher is shown in Figure L−3. This table corre- sponds to the system shown in Figures L−1 and L−2.
In this example, a special entry in the “Switcher” column (“DATA”) is used for the data router levels; this forces the Jupiter software to create Switcher Input and Switcher Output tables that are separate from those used for other switcher levels (Fig- ure L−6).
Note 1: A limitation in the present software requires that the entries in the “Switcher” column for the data router levels must be the same as, or come alphabetically before, all other names used in the Switcher column. In Figure L−3, this rule is satisfied because the letter “D” in “DATA” comes alphabetically before the letter “M” in “MAIN- ROUT,” and before the letter “O” in “OLDROUT.” This does not mean that the entries must be in alphabetical order within the table itself.
For DM 400/400A applications, the forward and reverse levels have the same physical level number (“16”). Reverse switch- ing is enabled for the reverse level (“R”); and, the reverse level is made to follow the forward level (“DATA” and “FOR”). The “Option” entry (normally “E”) is described starting on page 5−45.
The Switcher Description table is described in more detail starting on page 5−35.

Switcher VI RV Board #In #Out PLvL Follow Level Driver 3 LI 3 LO Option Audio Level DM 400 MC Off Time
5 DATA M1 193 32 16 Binary E FOR
6 DATA M1 193 32 16 FOR (DATA) Binary E REV
7 OLDROUT M1 10 10 3 TVS Prot VIDEO
Name chosen for data router must sort alphabetically before names used for other switchers (e.g., “D” comes in the alphabet before “M” and “O.”
† This is because the “#In” must always be one greater than the largest number used in the CP Input table. The largest number
used in the CP Input table will always be “192” (for the “safe” input, as described on page 5−32).
L−3 CM 4000 Installation and Operating Manual
Venus DM 400/400A

As an alternative scheme, it is possible to use the same entry in the “Switcher” column (for example, “MAINROUT”) for all levels, including the data levels (Figure L−4). In this case, the Switcher Input and Switcher Output tables will have columns for all switcher levels.

Switcher VI RV Board #In #Out PLvL Follow Level Driver 3 LI 3 LO Option Audio Level DM 400 MC Off Time
5 MAINROUT M1 193 32 16 Binary E FOR
6 MAINROUT M1 193 32 16 FOR (MAINROUT) Binary E REV
7 OLDROUT M1 10 10 3 TVS Prot VIDEO
Figure L−4. Name chosen for data router must sort alphabetically before names used for other switchers (e.g., “M” comes in the alphabet before “O.”
Note: A limitation in the present software requires that the entries in the “Switcher” column for the data router levels must be the same as or come alphabetically before all other names used in the Switcher column. In Figure L−4 this rule is satisfied because the entry “MAINROUT” in rows 5 and 6 is the same as the entry in rows 1 through 4, and because the letter “M” in “MAINROUT” comes alphabetically before the letter “O” in “OLDROUT.” This does not mean that the entries must be in alphabetical order within the table itself.
For a discussion of the ”DM 400 Off Time” entry, see page 5−47.

“D−2” Suggested Category/Number for control panel use. = “C−1”
Figure L−5. Example of DM 400/400A Data switching system.
L−4 CM 4000 Installation and Operating Manual
Venus DM 400/400A

Note: Since the software depends on logical numbers, which are actually row numbers on these tables, edit- ing one of the the tables can easily break the logical connection between them. For example, if new inputs are added to the top of the Switcher Input table, all following rows will be pushed down and assume new row (logical) numbers. To minimize this difficulty, Grass Valley recommends that all NEW entries be made at the end of the tables.
In a reverse switching scheme, a device feeding the “forward” level must use a logical input number on the forward level that is the same as its logical output number on the “reverse” level. In other words, the row numbers must match. See Figures L−5 and L−6.
Switcher Input − DATA
REV
1 SAFE
2 EDITOR
3 VCR1D
Logical input “1” should be re- served for use as the “safe input” for point−to−point applications, as described on page 5−45.
Logical input/output numbers are identical
Switcher Output − DATA
REV
“Safe” is used in row 1 as a place holder to maintain relative row number positions.
2 EDITOR
3 VCR1D
4 VCR2D
Figure L−6.
Conversely, a device feeding the “reverse” level must use a logical input number on the reverse level that is the same as its logical output number on the forward level. See Figures L−5 and L−7.
Switcher Input − DATA
REV
1 SAFE
2 EDITOR
Logical input “1” should be re- served for use as the “safe input” for point−to−point applications, as described on page 5−45.
4 VCR2D
Logical input/output numbers are identical
Switcher Output − DATA
REV
“Safe” is used in row 1 as a place holder to maintain relative row number positions.
2 EDITOR
3 VCR1D
4 VCR2D
Figure L−7.
L−5 CM 4000 Installation and Operating Manual

In data router applications, the reverse level should be entered on the CP Level Set(s), but should not be set to Switch, i.e., an “N” should be entered in the “Switch” column.
The input and output names in the previous tables must be assigned to Category/Entry selections. In the following examples, intended for use with a CP 3000−type panel, the “C” (for “controller”) category button will be used to select the Editor and the “D” (for “destination”) category button will be used to select the VCRs .

Figure L−8.

Category Entry Mnemnonic Level Set Button Auto Mnem Output Logical
Figure L−9.
In this example, the operator would select a destination such as “B−1” (VCR 1); then a source such as “C−1” (the editor). When TAKE is pressed the switch is made in the forward level; and, VCR 1 is automatically switched back to the editor in the reverse level.
L−6 CM 4000 Installation and Operating Manual
Venus DM 400/400A

(“Normal/Advise/Enforce”)
In most reverse data switching applications, one of the point−to−point Options (“Advise” or “Enforce”) should be selected for the “controller level.” The controller level is defined as the level receiving data from the editor or other control device . For more information, see page 5−45.
L−7 CM 4000 Installation and Operating Manual
Venus DM 400/400A

Some VTRs can act as controllers or tributaries. These can be connected with a “Y” cable to two Venus ports— one for use when the VTR is a controller, the other when the VTR is used as a tributary (see Figure L−14). If the VTR is operated only as a controller, or only as a tributary, then a “Y” cable will not be needed; the cable can instead be one of those shown on page L−4.
The following tables correspond to the system shown in Figure L−14. The basic rules for these tables have already been de- scribed (starting on page L−3).

Switcher VI RV Board #In #Out PLvL Follow Level Driver 3 LI 3 LO Option Audio Level DM 400 MC Off Time
DATA VM1 193 32 16 FOR (DATA) Binary E REV
Figure L−10.
Figure L−11. Figure L−12.


The Y Line table informs the system controller of a level, input, and output that have a Y line installed. Notice that each Y line requires two entries, and that the “crossover” ports (the “M” ports) are listed as inputs on the forward level and outputs on the reverse level:

Figure L−13.
Drop−down menu shows “Switchers” and “Names” from
Select the appropriate name from those
already entered on the Input (Figure L−11) or Output (Figure L−12) table.
(Figure L−10). Select appropriate data switcher.
L−8 CM 4000 Installation and Operating Manual
Venus DM 400/400A · Switcher Description table


“VR1−S” is suggested as the name for VR 1 when used as a Slave. “VR1−M” is suggested as the name for VR 1 when used as a Master.
Figure L−14. Example of Sony Master/Slave VTR ap- plication showing forward and reverse switcher levels.
L−9 CM 4000 Installation and Operating Manual
Venus DM 400/400A

CP Input and Output Sets
The input and output names in the previous tables must be assigned to Category/Entry selections. In the following examples, intended for use with a CP−3000−type panel, the “C” (for “controller”) category button will be used to select the master VCR and the “D” (for “destination”) category button will be used to select the slave VCR.
Input Set — KXYZ−INP
Category Entry Mnemonic Logical Auto Mnem Input
2 C 2 VR2M VR2−M
Output Set — KXYZ −OUT
Category Entry Mnemnonic Level Set Button Auto Mnem Output Logical
2 D 2 VR2S VR2−S
Figure L−15.
In this example, the operator might select a slave VCR destination such as “D−2” (VR 2); then select a master VCR source (i.e., a controller) such as “C−1” (VR 1). When TAKE is pressed, the VR 1 transmit (Tx) signal is switched through the cross- over cable to VR2; and, the VR 2 Tx signal is automatically switched back to VR 1. VR 1 is therefore the master and VR 2 the slave. If the operator selected input “C−2” and output “D−1,” then VR 2 would be the master and VR 1 the slave.
L−10 CM 4000 Installation and Operating Manual
Venus DM 400/400A · Operation

CP 3000/3010 Output Set Work Sheet

M−1 CM 4000 Installation and Operating Manual

M−2 CM 4000 Installation and Operating Manual
Output set worksheet

Jupiter ASCII Communications Protocol
Hardware connections for an external computer are shown on page 2−88.
Set−up in the Jupiter Control System File Server includes defining one or more ports as being ASCII in the Serial Proto-
col Table (page 5−30).
The control computer is identified on the MPK Devices table (page 5−123). You will need to define each port as being
type “Serial”, and give each port a CP Input set, CP Output Set and CP Level set. These sets will determine which levels,
inputs, and outputs are available to each ASCII port to control and status.
The ASCII Computer Interface is assigned to a system controller port and uses a simple ASCII data format defined be-
low. The serial protocol defaults to 9600 Baud, 8 Data Bits, No Parity, and 1 Stop Bit. Baud rates of 2400, 4800, 19.2K
and 38.4K are also user−configurable from the Jupiter Control System File Server. The control port uses XON (0x11) and
XOFF (0x13) to control command pacing if necessary.
All commands are in upper case ASCII. Space (0x20) characters are optional and will be ignored. Each command is fol-
lowed by a carriage return (0x0D). If a line feed (0x0A) is included it must follow the carriage return.
The controlling computer must take care to wait for a ZY or ZN response after each command before attempting to send
a subsequent command. Failure to do so will result in a ZN response, and possibly an XOFF condition. If switcher status
is received, wait for all levels to be statused before sending another command.
Here is a key to help you understand the following command descriptions:
OOO −−−> Router Switcher OUTPUT. This corresponds with the “Selection” number defined in this AS-
CII port’s CP Output Set. The range is from 000 to 999. (Previous releases had a range from
000 to 249.)
III −−−−−−−> Router Switcher INPUT. This corresponds with the “Selection” number defined in this ASCII
port’s CP Input Set. (Previous releases had a range from 000 to 249.)
N−1 CM 4000 Installation and Operating Manual

LLLLLLL −−−> Router Switcher LEVELS. This corresponds with a logical position in this ASCII port’s CP
Level Set. The range is from 1 to 7. For example, 1 refers to the first entry in the CP Level
Set, and 5 refers to the fifth entry in that same set. If no levels are specified, then the take is
assumed to apply to all levels defined in that set. Level number entries are NOT position−de-
pendent.
ASCII General Purpose Commands
ZA Acknowledge This command is used to see if the ASCII interface exists
and is running. A response of ZA is returned whenever a
ZA is received.
ZZ Reset This command forces the ASCII controller to reset. This
causes the interface to cancel all previous ZP, ZV, and
ZW commands. A ZX response is returned to the external
computer upon command completion. This ZX is also
returned whenever the interface is manually reset.
ZY Command Accepted This response is returned after the serial port has (ACK) successfully parsed the command and in the case of a
switch command has successfully issued the TAKE to the
system and received a switch response back from the sys-
tem. This does NOT mean that the command was success-
new command until receiving a ZY or ZN from the cur-
rent command. The amount of time for the response will
vary depending on system complexity and current system
activity. Also the number of switches involved in the com-
mand will affect the amount of time it takes to receive the
may result in ZR response(s) being returned before the
ZY response.
ZN Command Rejected A ZN will be issued when a condition occurs where (NAK) the current command cannot be executed. A ZN response
can be issued for several reasons such as an invalid com-
N−2 CM 4000 Installation and Operating Manual
ASCII Protocol

mand, an invalid command format, or an invalid input,
output or level. Invalid inputs, outputs and levels are
logged to the system logger. Also if the system is busy a
ZN will be issued followed by XOFF. When it is again
ready for the next command a XON will be issued. Note
that after the XON, response(s) from the prior command
may be issued (e.g. ZR response(s)).
Router Switcher Control and Status Commands
ZSOOOIIILLLLLLL Switch Request This command causes the interface to issue a TAKE
Switch Request to the routing switcher control system and
affects a single routing switcher output. If no levels are
specified, then ALL defined levels are assumed.
handling.
A remote computer can send a command with multiple
Switch Requests (older releases do not have this capabili-
ty). A single command can be up to 180 characters long
which allows switching of from 12−22 outputs (depending
on the specified levels). An example of a multiple Switch
Request follows:
This example command would switch outputs 0, 1, and 2
on levels 1 and 2.
ZROOO Status Request This command requests current switcher status for a single
output. The response is in the format:
ZROOOIIILLLLLLL.
If the status for the output is “split”, multiple responses
will be returned.
ZWOOO Watch Output This command causes the interface to watch the specified
output for any changes and report such changes. A request
to watch output “999” is a request to watch all defined
N−3 CM 4000 Installation and Operating Manual
ASCII Protocol

outputs in that port’s serial output set. All responses are in
the “ZR” format described above. When issued, this com-
mand also may result in an immediate ZR response for the
requested output(s). No ZR response(s) will be returned if
the requested output(s) do not have any inputs assigned to
them.
ZPOOO Lock Output This command LOCKS the specified output from being
changed by any system control device.
ZVOOO Protect Output This command PROTECTS the specified output from
being changed by any other system control device.
ZUOOO Unlock Output This command removes the LOCK or PROTECT from the
specified system output. If another system control device
or interface locked or protected this output, this command
will fail.
ZJOOO Report Lock Status This command will return a code based on which kind of
system control device or interface LOCKED or PRO-
TECTED the specified output. If the output is not locked
or protected, no response will be sent. The response codes
are as follows:
ZJ001−004 Party Line Control Panel
CP Level Set for this ASCII port.
N−4 CM 4000 Installation and Operating Manual
ASCII Protocol

Venus Monitor Configuration
When used with a Jupiter control system, the Venus output monitoring hardware allows verification of switcher performance without interrupting normal operations. A separate switching system is used to switch the Monitor Output to any output of the switcher.
Using a control panel, the operator picks an output as usual—in this case, the Monitor Output. The operator then selects an input, but this input is actually one of the switcher outputs.
Audio and video from Monitor outputs
CROSSPOINT BUS
MPK BUS
SWITCHER CONTROL PANEL
CONTROL SYSTEM
Figure O−1. Venus monitoring overview.
The number of the Monitor Output, which is used during software configuration, is determined by factory−set jumpers on the switcher motherboard. At the output card slots, the output number used is the output number for the output monitor. In larger, multi rack systems, all output cards are set to the same output number. By convention, this number should be the next output number range above the last real output in the system. On a 352 by 64 switcher system, the output numbers would be from 0 to 63. The output monitor would then be 64. In all cases, the monitor output number should be confirmed by checking the documentation package supplied with the switcher.
For details concerning external cable connections for output monitoring, please see the Installation Section of the Venus Installation Manual, part number 04-044592-004.
The Venus Installation Manual also describes installation of the VM 400 Analog Video Monitor Combiner and the DC 400 Digital Video Monitor Combiner.
O−1 CM 4000 Installation and Operating Manual

Figure O−2 is a block diagram of a Venus 64 x 64 switcher and its built−in 64 x 1 monitor switcher. In this example, the monitor output (lower right corner) has been set with a jumper to the highest output number plus 1, or “64.” The crosspoint marked “x” means that the monitor output has been switched to physical input 0 of the monitor switcher, which corresponds to physi- cal output 0 of the Venus itself.
Various software tables must be used to establish the switcher as having 65 outputs; to assign a name and category/entry num- ber to the monitor switcher output; and to assign a name and category/entry number to each monitor switcher input.
64 x 64 Venus switcher
2 3 0 4 1
Internal 64 x 1 monitor
A 1
63 63 “Ou63” A 6
Figure O−2. Example of Venus monitoring system.
O−2 CM 4000 Installation and Operating Manual

DM 400 Switcher Level VI RV MC Board #In #Out PLvl Follow Level Driver 3 LI 3 LO Option Audio Off Time
1 MainRout VIDEO M1 64 65 1 Binary NONE 2 MainRout LEFT M1 32 65 2 Binary LEFT 3 MainRout RIGHT M1 32 65 6 Binary RIGHT 4 MainRout TC M1 16 65 3 Binary NONE
Figure O−3.
Switcher Output − MainRout
Figure O−4.
Logical Output Pass Name Security S−T Word VIDEO LEFT RIGHT TC
63 VT15 S 63 64 MON S 64
Output Set — QC−OUT
Auto Logical Category Entry Mnem Mnemonic Output Level Set Button
Figure O−5.
Switcher Input − MainRout
Figure O−6.
Name VIDEO LEFT RIGHT TC
63 VT15 063 64 OUT0 000 65 OUT1 001 66 OUT2 002 67 OUT3 003
Auto Logical Category Entry Mnem Mnemonic Input
1 A 0 OUT0 OUT0 2 A 1 OUT1 OUT1 3 A 2 OUT2 OUT2
Figure O−7.
O−3 CM 4000 Installation and Operating Manual

The following example assumes that the Venus has been set up as described above.
O−4 CM 4000 Installation and Operating Manual
Venus Monitor

CE 3000 Matrix Control / PL 3000 Party Line Interface SC 3000 Serial Control / VG 3000 Video Display / Status Generator
These controller boards, which were part of the original BCS 3000 Control System, have been replaced by the VM/SI 3000 and CM 4000 Control Systems. As of Jupiter software release 7.1.0 they are no longer supported and should not be used in systems with current software.
P−1 CM 4000 Installation and Operating Manual

P−2 CM 4000 Installation and Operating Manual

PS 300 110/220 VAC Power Adaptor Kit Installation Instructions
This kit (assembly part no. 44−046442−001) provides all hardware needed to modify one CP 300 Series control panel for direct connection to a 110/220 VAC power line. The CP 300 Series includes the CP 300, CP 310, CP 320, CP 328, and CP 330.
The kit includes an add−on chassis (which mounts on the rear of the panel) and a detachable, 3−prong AC power cord. The chassis measures approximately 12 in. wide x 5 in. deep x 1−3/4 in. high and includes a TE/PE grounding strap and fuse holder.
Figure Q−1.
CM 4000 Installation and Operating Manual Q−1

For more information about the MPK cables, please refer to page 2−63.
CM 4000 Installation and Operating Manual Q−2

Status and Error Codes
RED LEDS RED LEDS GREEN LEDS
DS1
DS2
DS3
DS4
DS5
DS6
DS7
DS8
DS9
DS10
DS11
DS12
DS13
DS14
DS15
DS16
DS17
DS18
DS19
S1
S2
S3
SELECT B
SELECT A
OUT 0
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
INPUT
OUTPUT
FAN
MEM.CLR
OUT 0
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUTPUT BUS FAULT 0−7
FAILURE ALARMS 3 SWITCHES NOT ACCESSIBLE THROUGH
OUTPUT DRIVRS A OR B ACTIVE
FRONT PANEL
ON = A OFF = B
Figure R−1. CB−3000 front panel status window.
The window on the front of the chassis allows the fault indicators on the front of the CB−3000 card to be viewed. (See Figure R−1) Beginning at the left side of the window, the first eight RED LEDs are DS1 through DS8, the Output Fault Memory LEDs. These LEDs are normally off. If any of the LEDs are on, a fault has occurred at some time on the indicated crosspoint bus output.
The next group of three RED LEDs are the INPUT_FAILURE, OUTPUT_FAILURE, and FAN_FAILURE LEDs, respectively. These LEDs are normally off. An on condition indicates the fault described by the LED name.
Three local changeover switches on the front of the CB−3000 card are not accessible from the front panel. They are the local equivalent to the front panel pushbuttons.
The eight GREEN LEDs at the right side of the display window are Output Configuration LEDs DS12 through DS19. They indicate the A output drivers are active on their respective outputs, 0 through 7. These LEDs are normally ON, indicating the default A position. Any LED that is OFF indicates that its respective output has switched to the B driver position.
CM 4000 Installation and Operating Manual R−1

Status and Error Codes
Startup and shutdown codes
Compiled: May 04 2001, 14:19:49 CVS tag: COMBO_6_1_0.


DE A critical disk error occurred
Compiled: May 04 2001, 14:19:49 CVS tag: COMBO_6_1_0.
Short message / Detailed description
01 Logging configuration version is %s.
CM 4000 Installation and Operating Manual R−2

Status and error codes
This message is logged anytime the log file is changed. It identifies the version of the logging con- figuration so that the log viewer knows how to read the files.
02 Logger Error.
This is a generic message for logger errors. These messages will typically only get logged to the con- sole. This message is typically serious and warrants technical support.
03 Video SYNC input lost.
The board could no longer detect a valid video SYNC reference. Check to make sure that the SYNC cable is properly connected to the board and that the SYNC source is still active. If SYNC is not re- stored, frame−accurate operations will not be possible.
04 Time code input lost.
The board could no longer detect a valid time code signal. Check to make sure that the time code cable is properly connected to the board and that the time code source is still active. Also insure that video SYNC is connected to time code generator. If time code is not restored, frame accurate opera- tions will not be possible.
05 Ethernet interface %s inactive for %d seconds.
The board could no longer detect activity on the ethernet interface. Check to make sure that the LAN cable is properly connected to the board and that it is still connected to an active network. If the LAN is not restored, it will not be possible for the board to communicate with the rest of the system, resulting in loss of status or control from other LAN devices.
06 Unconfirmed and unasserted takes on xpt (crosspoint) bus.
The board attempted takes on the xpt bus, but the takes were unconfirmed and not asserted. This usually indicates an open connection to the router or that the crosspoints were not valid for the router. Check to make sure that the xpt bus cable is properly connected. If this does not fix the prob- lem, double check the router’s configuration.
07 Video SYNC locked to %s.
The board has locked to a valid SYNC reference. When this occurs, SYNC is properly connected and working. However, verify that the SYNC standard is correct for the system.
08 Time code acquired.
The board detected a valid time code signal. When this occurs, time code is properly connected and working.
09 Unexpected jump in time code to %02x:%02x:%02x:%02x.
The time code input has jumped to a value that is not continuous with the current time line. This may be expected if the input was just acquired or the time code generator was set to a new value. Since the video time line was adjusted abruptly, some deferred events may be invalid. If this mes- sage occurs without cause or the time code value is unreasonable, check the generator and its con- nection to the system.
0A Ethernet interface %s appears active.
The board detected activity on the ethernet interface. When this occurs, the ethernet is properly con- nected and working.
0B Unable to initialize udp socket.
The system was unable to initialize the ethernet connection. This is typically a critical error and will result in lack of communication with other systems.
0C Output %d, level %d is locked.
CM 4000 Installation and Operating Manual R−3

Status and Error Codes
An attempt to switch the indicated output failed because it was locked.
0D Output %d, level %d is protected.
An attempt to switch the indicated output failed because it was protected.
0E Failed to change from configuration %s to %s.
The system failed to change the configuration. The system will continue to function, but with the old configuration set. Check the new configuration set and try again.
0F SNTP client error %s for server %s
The application could not synchronize its internal POSIX clock with the remote server using the Simple Network Time Protocol (SNTP). The time management software will attempt to perform synchronization periodically to maintain the long term accuracy of its internal POSIX clock. Note that the POSIX clock is not the same clock used by the system to manage frame−accurate operations. That clock, known as Video Time, is genlocked to the video SYNC reference. The POSIX clock is used as a reference for Video Time when the schedule permits an adjustment. No action needs to be taken on this event, unless the remote SNTP server is the only source of trusted time and several consecutive failed attempts have been logged. Check to make sure the SNTP server is available over the network and its NTP service is running correctly.
10 Error %d getting status back from router.
The system failed to read status from the crosspoint bus. This is typically a critical error.
11 Mismatch in status count, %d received, %d expected.
The switch count received back from the router does not match the expected count. This typically indicates a critical software error.
12 Could not take xptStatusSem semaphore!
The system failed to communicate with the crosspoint bus. This is typically a critical error.
13 %s: Actor never ran.
The command scheduler controls all commands, which are known as actors. This message indicates that the actor did not execute. This may be because there was not enough time to allow it to run. This should not effect other commands.
14 Reinitializing status because %s.
Router status has been reinitialized due to a request for a PMEM clear, an adjustment in the configu- ration, or a change in the application.
15 Standby board, status will synchronize with the master.
The board is currently the slave board in a redundant pair. Status must be initialized by listening to the crosspoint bus refresh takes.
16 Cannot access status file \”%s\”, error 0x%X: %s.
The current router status is kept in a directory on the hard drive. A file in this directory could not be accessed. This may indicate a problem with the disk drive.
17 Cannot create status directory \”%s\”, error 0x%X: %s.
The current router status is kept in a directory on the hard drive. This directory could not be created, which may indicate a problem with the disk drive.
18 Unable to initialize %s component.
The application was unable to initialize a component. This is usually a fatal error.
CM 4000 Installation and Operating Manual R−4

Status and error codes
19 Maximum number of status observers exceeded, only %d can be attached.
The system can only handle a limited number of observers and has reached maximum capacity.
1A Failed to notify switch requestor (named %s) of a status change.
The status that should have been returned to the switch requestor could not be scheduled. This im- plies that the system is overloaded, but it should not happen on a properly balanced system.
1B Error %d sending switches to the router.
An error occurred sending the switch to the router hardware. This implies a hardware error.
1C Could not create \“%s\” task.
A task on the system was removed. This indicates an overloaded system.
1D SwitchListStore has exhausted its supply of RCDataLists.
The system has a limited number of switch lists. If this supply is exhausted, no more switches can be performed.
1E The maximum number of switches was exceeded.
As the system processes a switch request it may add additional switches due to system configuration (follow switches, etc.). The addition of these switches has exceeded the maximum number of switches allowed in a single switch list.
1F ConfirmAll has been turned %s for VenusRouterDriver.
If confirmAll is turned on, all switches will be confirmed regardless of the response from the router (even if no router is connected). This is typically used in development.
20 Cannot find file system: ‘%s’.
The indicated file system could not be found. This is typically a critical error. It may indicate a bad disk drive.
21 Error %d trying to initialize the crosspoint driver.
The system could not initialize communications with the crosspoint driver. This is typically a critical hardware problem.
22 An error was encountered while trying to resolve a path for the switch(es) received.
The switch(es) could not be completed due to an error in the path resolver.
23 POSIX clock adjusted by %d mS from %s
The system’s POSIX clock was adjusted to match a reference source. This type of adjustment occurs periodically every 17 minutes. Typically, the clock is adjusted by a small value (less than 1 second). If the adjustment is large (greater than 1 second), this message will be logged. This should not be a problem if it occurs infrequently.
24 POSIX clock set to %d/%02d/%d %02d:%02d.
The system’s POSIX clock was set to the indicated time, which is is most likely the result of a manu- al adjustment initiated through the call to setClock. Note that the Video time line was also recali- brated as a result of this change and could have resulted in a loss of any deferred events already in the time line.
CM 4000 Installation and Operating Manual R−5

Status and Error Codes
The system did not receive a response from the bootp server (JNS). This message is typically logged because the JNS control center is not running. A network problem is also possible. The system will continue to operate using the previous application software and configuration. This will give unde- sirable results if the configuration or software has changed since the last reboot. If no changes have occurred, this should not be a problem.
26 Bootp failed: no vendor extensions.
This message is logged when a bad bootp response is received. The bootp response must have ven- dor specific information to be useful. There may be another bootp server on the network erroneously configured to reply to this system.
This message is logged when a bad bootp response is received. The bootp response must have ven- dor specific information to be useful. There may be another bootp server on the network erroneously configured to reply to this system.
28 Bootp succeeded from server %s
This message indicates that a good bootp response was received from the indicated server.
29 Using configuration from %s for Bootp.
A valid bootp response was not received. The indicated source is supplying the required information.
2A Using bootline and defaults for Bootp.
A valid bootp response was not received. The built−in defaults are supplying the required informa- tion.
2B Activate command received−−updating code.
The “activate” command was received. This is used to change the configuration set without reboot. However, the system will reboot if the new configuration set contains changes that requires it.
2C Reboot command received−−rebooting
The “reboot” command was received. This is used to reboot the system.
2D Clear Persistent Memory command received−−memory will reinitialize on reboot.
The “clear persistent memory” command was received. This is used to clear the router status on the next reboot. This has no immediate effect and any subsequent changes to router status will also be cleared on the next reboot.
2E Post Mortem command received. Critical errors will not cause a reboot.
The “post−mortem” command was received. This is used to tell the system to not reboot on a fatal error. The system tasks will be suspended so further investigation can be performed.
2F Unsupported %s command received−−ignored.
The system received an unsupported command. The system may be out of sync with the control cen- ter. The command is ignored.
30 Scheduling system reboot
Because the system is a high−performance system a requested reboot will be deferred till the system completes its high−priority tasks. This typically takes only a few seconds.
31 Scheduling configuration swap
Because the system is a high−performance system a requested configuration change will be deferred till the system completes its high−priority tasks. This typically takes only a few seconds.
32 Checking CRC of %s
CM 4000 Installation and Operating Manual R−6

Status and error codes
This is an informational message indicating that the CRC of the specified file is being checked. This allows the system to ensure that no file corruption occurred.
33 %s is up to date
This is an informational message indicating the specified file is up to date and need not be reloaded to the system.
34 %s saved as %s
This is an informational message indicating that the specified file was downloaded successfully and renamed.
35 Downloading file %s
This is an informational message indicating that the specified file is being downloaded.
36 Cannot download file \“%s\” (Error number 0x%X: %s)
The file download failed. This is typically a critical error.
37 %s CRC failure, Computed=0x%04x Expected=0x%04x
The CRC on the downloaded file was not correct. This indicates a corrupted file.
38 Downloaded %s −− %d bytes in %ld mS
This is an informational message indicating that the specified file was downloaded (giving the byte count and the time required to download it).
39 Configuration successfully loaded
This is an informational message indicating that the specified configuration was successfully loaded.
3A Could not create UDP socket errno = 0x%x
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
3B Could not shutdown UDP socket errno = 0x%x
A problem with the LAN hardware or external LAN connections may exist. This is typically serious.
3C Could not close UDP socket errno = 0x%x.
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
3D Logical UDP port 0x%x overlaps standard port at 0x%x.
Error trying to use a reboot or com port that is already in use via the Jupiter / BootP tasks. Check Jupiter com and boot port numbers.
3E Could not bind UDP socket for port 0x%x errno = 0x%x.
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
3F Could not set option 0x%x on UDP port 0x%x errno = 0x%x.
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
40 Send failed for UDP port 0x%x errno = 0x%x ip = 0x%x
Unable to send a message to the UDP port at this ip address. The network may not be configured correctly or not physically connected correctly. Verify the correct UDP port numbers and IP address- es are being used.
CM 4000 Installation and Operating Manual R−7

Status and Error Codes
41 Receive failed for UDP port 0x%x errno=0x%x
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
42 Invalid UDP destination name ’%s’ on port 0x%x
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
43 Error setting non blocking for port 0x%x
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
44 Invalid logical multicast address 0x%04x
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
45 Could not create ’%s’ task
There may be a problem with the LAN hardware or external LAN connections. This is typically seri- ous.
46 Could not create the virtual master array (step %d).
The virtual input master array (list of outputs that can be used as virtual inputs) was not created. The system will not be able to perform virtual input switching. (Step indicates where the process failed)
47 The virtual input master table is corrupt (cause %d).
The virtual input master array is corrupt. The system will not be able to perform virtual input switch- ing. (Cause indicates where the corruption occurred.)
48 Cannot find any levels configured for this board (%d).
There are no levels configured for this board. You must build a valid configuration and reboot.
An improper configuration request was made. This is a programming error and should be reported to technical support.
4A Cannot load serial card for this board.
Unable to load files for the coldfire serial card. Either the boot loader or serial processor application program failed to run on one or more serial processors. This indicates a failure of one of the serial processors.
4B SerialTimeSync failed to set a serial processor time reference.
A synchronize time command is sent to each serial processor. If the processor fails to set its time this event is logged. The processor may also fail to load protocols if the synchronize time command fails. This indicates that the processor control channel is not responding.
4C One or more serial protocols did not start correctly.
One or more of the configured serial protocols failed to load on one or more of the connected serial processors. This indicates a serial processor control channel failure or incorrect protocol module. A probable cause is that the serial protocols tables define an invalid protocol for this board.
4D Serial processor watchdog expired on card %d.\nProcessor Restarted.
The indicated serial processor failed to reset the hardware watchdog timer indicating that a hang condition existed on the processor. The processor was reset by hardware and its program will be re- started.
CM 4000 Installation and Operating Manual R−8

Status and error codes
4E Error 0x %x scheduling actors for the router control device.
An error occurred when trying to schedule actors to the command scheduler. System may be over loaded. This is typically a critical problem.
4F Configuration error for router control device %d.
An error occurred when trying to get the logical CP number for this device. The device was config- ured in the protocols table but could not be found in the MPK devices table.
50 Error creating watch list for deferred events.
When a time−deferred switch is created, a watch list observer is created so that the event handler will be notified when the event runs. This message indicates that the system was not able to create the watch list observer. Possibly too many observers are being used.
51 Failed to allocate memory.
The system tried to allocate memory but failed. This is always a fatal error.
52 Failed to free memory.
The system tried to free memory but failed. This is always a fatal error.
53 Cannot open configuration file \“%s\” (Error number 0x%X: %s)
There was some problem opening the configuration file.
54 Cannot find configuration image \”%s\” (\”%s\”).
The configuration image was not found in the configuration file. The old configuration image will be used (or the default if a valid one has not been loaded yet). This will typically give undesirable re- sults.
55 Cannot swap to alternate configuration image \”%s\”, it is not valid.
A swap was attempted on the configuration image but the alternate image was invalid. The old image will continue to be used. This may give undesirable results.
56 Cannot get the ethernet address for this board.
The ethernet address is needed to determine which configuration to load. If it cannot be determined the board will not operate. This is always fatal.
57 Cannot find this board number (%u) in the configuration table.
Each board has a unique number. This number is used to determine which configuration parameters are used. If the parameters for the board cannot be found, the old configuration will be used. This will usually result in undesirable results.
Out of memory! When the serial card memory heap is completely exhausted, this message is logged and the task allocating memory hangs.
Heap nearly exhausted! When the serial card memory heap is nearly exhausted, this warning mes- sage is logged.
Heap Free error! When memory on the serial card is freed, the currentHeapUsed value is decrement- ed by the size of the block being freed. If the current used value is negative, there is a problem with the heap memory management and this error is logged.
CM 4000 Installation and Operating Manual R−9

Status and Error Codes
Message transfer during last frame failed to complete. Determinacy of incoming messages was lost. When processing input messages and a message failed to be completely transferred in the previous frame this message is logged. It represents a determinacy error. Increments a serial input channel determinism error metric.
DPM access failure. The system was unable to write serial messages. This message is logged when the system is processing input messages and is unable to allocate DPM memory for writing. Incre- ments a serial input DPM access error metric.
Message transfer during last sync interval failed to complete. Determinacy of outgoing messages was lost. When processing output messages, if a message failed to complete in the last frame this mes- sage is logged. It represents an output determinacy error.
Message overflow. Outgoing message lost. While outputting serial messages to the frame processor the serial card ran out of memory and was unable to copy any more messages.
Data overrun error. A separate thread is watching all the port metrics overrun error counts. When any port’s overrun error count exceeds its previously logged count this event is logged.
Serial Card Flash Directory Initialized. When a new board is installed this event is expected. Any- time after initial installation if this event occurs the flash file system directories have both been cor- rupted and were re−initialized.
Primary directory was copied from the secondary directory. When the primary directory was checked, it indicated a data corruption problem and was replaced by the secondary directory copy because its contents checked ok.
The flash file system attempted to update the directory in memory, but the write to flash failed for the primary directory copy 1 or secondary directory copy 2.
A separate thread is watching all the serial port metrics error counts. When any ports line, protocol, or timeout error count exceeds zero or its previously logged value this event is logged.
When a message comes from a serial port protocol, it is transferred from the serial processor to the frame processor to be processed by the system. The protocol expects to receive either a positive or negative acknowledgement. If that response is not received within the specified timeout period, this event is logged.
Undefined serial processor log event. See message string.
66 Cannot run unit test for %s with production code
You cannot run unit tests when the code is compiled for production.
67 Could not create unit test task for %s
CM 4000 Installation and Operating Manual R−10

Status and error codes
Failed to create the unit test task.
68 Could not create unit test cleanup task for %s
Failed to create the unit test cleanup task.
69 Unable to initialize the bootp information. Activate a valid configuration and start the bootp dae- mon.
The application was unable to initialize the bootp information. The application could not determine its IP address. Make sure a bootp server is running and a valid configuration is activated.
6A Unable to initialize the control center. Activate a valid configuration and start the bootp daemon.
The application was unable to initialize the bootp information. The application could not find a valid configuration file. Make sure a bootp server is running and a valid configuration is activated.
6B Cannot find host name for %s in host table.
A host name was specified without an IP address. The host name was not found in the hostname table. This time server will be inactive.
6C Cannot add host name for %s to the host table.
A host name was specified with an IP address. An attempt was made to add the host name to the hostname table. This should not affect operations.
6D %d deferred events for %s:%02d reassigned for makeup.
A time line discontinuity has caused deferred events to be passed over for execution. Since these events now exist in the past, the system will attempt to perform these events as the current schedule permits. This is evidence of a serious problem with the system video time line. It may be caused by an abrupt change to the time code input or a problem with video SYNC. Check to make sure these are working and properly connected. If the time on the time code generator was adjusted, make sure that these changes do not occur if deferred events are pending that may be swallowed by the adjust- ment.
Some system error occurred. This is usually fatal.
CM 4000 Installation and Operating Manual R−11

Status and Error Codes
This software operates with Jupiter release 4.0 or later.
The following FATAL ERR codes can appear on the CP 38XX series of Control Panels. These are firmware errors that the panel found while running. The following list will help explain these errors and possible actions to be taken.
10xx − Where xx is the unknown MPK message type received by the panel. The biggest cause of this error is a wrong Control Panel type being defined for this panel in the MPK table. Check for correct Control Panel type in the MPK table on the main File Server. If correct panel type is defined, call Grass Valley Technical Support.
11xx − Where xx is the data that can NOT be written into the build in EEPROM. This could possibly be a hardware failure. Call Technical Support.
3200 − Could NOT send an ACK in response to receiving a message, still had previous data in transmit buffer. This could be a possible hardware failure. Call Technical Support.
3300 − Received MPK message that had a byte count too large. Possible cause, wrong panel type or something wrong with MPK bus. Call Technical Support.
3400 − Received transmit buffer empty IRQ when there was no data that was sent. Possible hardware problem. Call Technical Support.
3500 − Could NOT send a NAK in response to receiving a new message before processing last message. Call Technical Support.
3600 − Could NOT send a NAK in response to receiving an illegal check sum on the last message. Call Technical Support.
80xx − Where xx is the column number that is not on this panel display. The biggest cause of this error is a wrong Control Panel type being defined for this panel in the MPK table. Check for correct Control Panel type in the MPK table on the main File Server. If correct panel type is defined, call Technical Support.
81xx −Where xx is the column group trying to blink on this panel type. The biggest cause of this error is a wrong Control Panel type being defined for this panel in the MPK table. Check for correct Control Panel type in the MPK table on the main File Server. If correct panel type is defined, call Technical Support.
Most of these problems that say call Technical Support could be a hardware problem. The first thing that the customer needs to do is check all MPK devices that are connected to the effected MPK bus for the possibility of having two or more devices with the same device address. If no problems are found, disconnect the panel from the MPK bus. Turn the power off and then back on again to reset the panel. Run all the tests in the diagnostic mode to check for possible control panel hardware problems. A MPK loop back cable to connect the receive and transmit lines will need to be made to check the panels MPK port. If any problems are found, call Technical Support to get the panel repaired. If no problems are found, check the MPK bus for possible problems.
CM 4000 Installation and Operating Manual R−12

TSL UMD Setup Guide
The TSL Under Monitor Display panels are manufactured by Television Systems Limited (http://www.televisionsystems.ltd.uk), and can be controlled via RS−422 serial connection with VM/SI 3000 control boards running Jupiter 7.2 or newer software.
The TSL UMD panels have RS−422 serial data and 24 V power on the same connector, so custom−built cables will be necessary to connect the TSL UMD panels with Jupiter. Some TSL UMD panels use DB−15 connectors, and some use RJ−45 connectors, so great care should be taken in their construction. Also, the ground pins (“0V” in the TSL manuals) on the TSL UMD connectors should be connected to the ground pins on the Jupiter VM/SI−3000 control boards to ensure proper communications. Please refer to the TSL UMD manual for the exact connector pinouts.
Figure S−1 is an illustration of a cable for a TSL “UMD−QD8” quad display panel (DB−15) and an “UMD−D8C” single display panel (RJ−45), connected to a VM 3000 (DB−9).
There are some setup issues that need to be addressed. The TSL UMD−QD8 panel needs to be set in “Error Mode 3” using the recessed front panel switches. Please refer to the TSL manual for more information on how to set that mode. All panels need to be set in “Mode 1” to communicate with Jupiter via the serial connection.
CM 4000 Installation and Operating Manual S−1

TSL UMD Setup Guide
G
G
G
+24V
G
+24V
+24V
Rx+ Receive plus Rx− Receive minus Tx+ Transmit plus Tx− Transmit minus G Ground
G
+24V
+24V
RJ45P
CM 4000 Installation and Operating Manual S−2

The recessed front panel switches are also used to select a serial address for the TSL UMD panel. The valid addresses are 0 – 125. This address is entered in the Jupiter MPK Devices Table in the “Address” field. If the TSL UMD has two displays, then the left−hand display has the TSL serial address entered in the address field, and the right−hand display has that address plus 100. For example, in a two display TSL panel, with the address “5” chosen, the left−hand display is address “00000005” in the MPK Devices Table, and the right−hand display is address “00000105”. Please see the drawing below.
Recessed Front Panel Switches Address “00000005” Address “00000105”
Also, if there are more than two displays in a single TSL UMD chassis, the left−most two displays use the address that is set by the front panel switches (again, please refer to the TSL manual for more information on how to set panel addresses). The right−most one or two displays use the next sequential address. For instance, on the UMD−QD8 panel with four displays, if the front panel switches are used to choose an address of “8”, then the left two displays are addresses “00000008” and “00000108” in the Jupiter MPK Description Table, and the right two displays are addresses “00000009” and “00000109”. Please see the drawing below.
Recessed Front Panel Switches Address “00000008” Address “00000108” Address “00000009” Address “00000109”
In all other respects, the TSL UMD panels behave exactly like the UMD3A UMD panels, including being able to be defined as Saturn UMD panels, and controlling the tally lamps (Output Tally).
CM 4000 Installation and Operating Manual S−3
Input Source Assignment · Figure S−2 · Figure S−3

TSL UMD Setup Guide
CM 4000 Installation and Operating Manual S−4

Grass Valley 8964 OMD (On Monitor Display) module
The 4−channel GV 8964 OMD (or on−screen display) board, which is based on the 8964 ENC SDI to NTSC/PAL Encoder Module, mounts in the 8900 TFN−V Module Frame. In this application, each of the four channels can insert an 8−character status mnemonic into a digital video stream and display the result on the analog output. Figure T−1 shows the status mnemonic “CAMERA 1” inserted into one of the OSD board’s four video channels.
Each module frame can contain 10 modules for a total of 40 outputs per frame.
Figure T−1. Example of OSD application. The device names shown correspond to those used in the Jupiter Configuration Procedure discussion below .
Digital video router Crosspoint Bus

with “OSD1,” “OSD2,” ”OSD3,” and “OSD4” channels provided by 1 8964OMD OSD
Each 8964 channel is associated with a particular Logical Output of the router. The source mnemonic is displayed as white characters over a black background in the lower part of the screen.
The CM 4000 / AccuSwitch communicates to each Module Frame via the Jupiter LAN and a TCP connection.
The OSD also has the ability to display the current time on a separate line.
CM 4000 Installation and Operating Manual T−1
Module

GV 8964OMD OSD Module
The MPK Devices table requires an entry for the module frame, and a separate entry for each video channel of each OSD board.
The module frame entry consists of an MPK Device name, a Device Type, and the names of three sets. See Figure T−2.
Figure T−2. Module frame entry on MPK table (example).
Devices word In Panel Out Panel
Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
MNF−LEV
The MPK Device name must be exactly the same as the Board Name for the module frame on the Network Description table. The Device Type is “MNF” (Modular Network Frame). Of the three sets, only the Output set is used; the Input Set and Level Sets are placeholders needed to satisfy the compiler.
Input Set. This placeholder set, type Serial, must be created with at least one Entry number and one Logical Input. See Figure T−3.
Figure T−3. Placeholder Serial−type CP Input Set (example).
Input Set — MNF−IN
Output Set. This set, type Serial, is used to assign a router output to each OSD channel.
CM 4000 Installation and Operating Manual T−2

GV 8964OMD OSD Module
Figure T−4. Serial−type CP Input Set (example).
Output Set − MNF−Out
SVR1
SVR2
VT01
The Entry number is used to identify an OSD board and channel number, which is then associated with a Logical Output number of the router. For example: Entry “0” = module 0, channel 0; this channel will monitor the status of router output “STU1.” “3” would be module 0, channel 3; it will monitor router output “VT01.” If there is another module, then the next row would show Entry “4” for module 1, channel 0, etc.
Level Set. This placeholder set, type CP 3000, must be created with at least one Level entry. See Figure T−5. The entries are not used.
Figure T−5. Placeholder CP Level Set table (example).
CP Level Set — MNF−LEV
Mnemonic Level Break Switch
Each OSD channel also requires an entry on the MPK Devices table consisting of an MPK Device name, a Device Type, and the names of three sets. See Figure T−6.
Figure T−6. MPK table (example).

Board Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
A device name is created here for each OSD channel. The Device Type is “OSD.” Three CP sets must also be specified.
CM 4000 Installation and Operating Manual T−3

GV 8964OMD OSD Module
Input Set. This set, type UMD3A, is the source of the mnemonics that will be inserted into the video. It must include all router inputs that need to be available to the monitored output. See Figure T−7.
Figure T−7. UMD3A−type CP Input Set (example).

Output Set. This set, type UMD3A, is only used to enable a clock display on a selected channel. If this is desired, enter “@@Time@@” as the Mnemonic and select the router output.
Figure T−8. Clock−enable entry on CP Output Set (example).

Category Entry Mnemnonic Level Set Button Auto Mnem Output Logical
(The Category and Entry fields are not used, but they must have entries to satisfy the compiler.)
Level Set. This set, type CP 3800, determines which level will be statused. In the example shown in Figure T−9, the video level will be statused. The Mnemonic field is not used (but must include text as a placeholder).
Figure T−9. CP Level Set table (example).
CP Level Set — OSD−LEV
Mnemonic Level Break Switch
CM 4000 Installation and Operating Manual T−4
aaaa VIDEO

10Base2 − a coax version of ETHERNET. Uses a 4.9 mm (0.19 inch) diameter, 50−ohm coaxial cable (RG−58) and BNC connectors, but runs at the same speed (10Mb/s) as ETHERNET. The Jupiter system uses this standard between VM/SI controllers and Saturn. It is also used by the original BCS 3000 controllers.
10/100BaseT − an ETHERNET configuration that uses twisted pair wiring (typically Cat 5 UTP unshielded twisted pair cable with RJ45 8−pin connectors) to transmit data up to 100 Mbps.
4000 series − (Saturn) these products are very similar to the Saturn 3000 and 3500 series products but have the “crescent” style front panel.
A board - ES−3000 used for Thomson Automation applications. Now obsolete.
AA board − analog audio processor for Saturn Master Control switcher.
AccuSwitch − control application for CM 4000. Provides interface between Grass Valley Crosspoint Bus routers
and certain automation systems, including Thomson Broadcast Automation.
AES − Audio Engineering Society. Internet address: http://www.aes.org
AES3−1992 − AES Recommended Practice for Digital Audio Engineering −− Serial transmission format for two−
channel linearly represented digital audio data.
AES11 − AES Recommended Practice for digital audio engineering −− Synchronization of digital audio
equipment in studio operations.
AFV − Audio−Follow−Video. Normal operation of a distribution switcher where selection of a video source
automatically selects audio from that source. Example: selection of VTR1 video automatically selects VTR1 Audio 1 and VTR1 Audio 2 as well.
Alamar − manufacturer of broadcast automation systems. Acquired by Philips.
Ampex bus − see SERIAL BUS.
Andromeda − logical signal processing system developed by Systems group Griesheim. Functions include eval-
uation of GPIs, tally light control, evaluation of contact closure failure indications from devices such as master control switchers and video servers, and automatic, emergency switching.
AV board − analog video processor for Saturn Master Control switcher.
BCS 3000 − Bosch Control System. Predecessor of Jupiter Facility Control System, originally developed by
Bosch Video Systems Division (now part of Grass Valley). Used Hewlett−Packard UNIX−based file server. BCS−3000 controller boards included the CE 3000 Matrix Controller, the SC 3000 Serial Control Interface, the PL 3000 Party Line Interface, and the VG 3000 Dual Video Display Status Generator. Most of the func- tions of these controllers were combined in the VM 3000 Control Processor. Some facility control systems built by BTS combined BCS controller boards with a Jupiter PC file server.
Glossary−1 CM 4000 Installation and Operating Manual

binary super crosspoint bus - similar to super crosspoint bus, but the units digits are allowed to cover the range
of 0 to F, rather than 0−9 as in previous switcher systems. Generated only by the Jupiter, CE-2500, and BCS 3000 control systems.
breakaway − independent operation of a switcher level. Same as “split.” Contrasts with normal AFV operation.
Example: selecting video from VTR1 but audio from Announce Booth 2.
BTS − Broadcast Television Systems. A joint venture of Bosch and Philips. Now part of Grass Valley.
bus − in distribution switching, a channel leading to an output or destination. Example: “controls 20 buses” means
being able to select sources for 20 destinations.
button−per−input/output control panel − buttons are dedicated to a particular source or destination. As
opposed to CATEGORY/NUMBER control.
category/number selection method − operator first picks category (example: VTR); then unit within category.
CE 3000 − Matrix Controller. Interface between LAN and CROSSPOINT BUS. Now obsolete.
chop − rapid, back−and−forth switching between two inputs.
CM 4000 − hardware platform developed as follow−on to VM 3000.
configuration set − a file server directory containing files that are downloaded to CONTROLLER BOARDS. These
files are used to establish network addresses, switcher input and output names, types of VTRs in system, etc.
controller board − (1) term used for the interface unit between Jupiter LAN and the RS−422 bus. Includes VM 3000
Control Processor, SI 3000 Control Processor, and VG 3000 Video Display/Status Generator. Also refers to BCS 3000 boards: SC 3000 Serial Control Interface, CE 3000 Matrix Control, and PL 3000 PARTY LINE Inter- face. In ESBUS terminology, each of these boards functions as a coupler, gateway, and bus controller. (2) Con- certo router controller module such as the CRS−MC−C2.
CP 3200 − a Jupiter GUI control panel associated with JNIA. Superceded by the JNS Software Control Panel Suite.
CP 3300 − an X−Y panel, developed by Philips BTS in Germany, with soft keys displaying configured names. The
hardware contains 2 lines of 20 characters and displays four character and eight character source and destina- tion names.
CP 3310 − an X−Y panel similar to the CP 3300 that can display status for either five or eight outputs.
CP 3320 − a control panel developed by the Grass Valley Systems group in Germany.
CP board − control panel for Saturn Master Control switcher.
CPL − Control Point Language. Protocol used in SMS7000 Control System.
crosspoint − distribution switcher circuit where input signal can be connected to output bus. A 10 x 10 crosspoint
board has 100 crosspoints.
Glossary−2 CM 4000 Installation and Operating Manual

Crosspoint Bus - Also called the matrix bus. A five−pair bus that carries switching and status commands between
the crosspoint (matrix) cards in the router and the control device. Used with all switchers developed at the Salt Lake City design center, including Trinix and Venus.
The control device could be any one of a large number of devices, including a CE-300A Control Board (inter- nal to Mars), a SC 400 Control Board (internal to Venus), a CE 3000 Matrix Controller (BCS 3000 control system), a CE 2500 Control Electronics chassis, a VM 3000 Control Processor (Jupiter), or a CE 2200 (PARTY
LINE system).
The protocol for this bus has changed through the years to accommodate larger and larger switchers with increasing numbers of levels, being identified as “standard,” “extended,” “super,” and “binary.” For example, the binary protocol uses binary (rather than BCD) coding to increase maximum control size to 1024 x 1024 on 127 levels.
The “octal” protocol type is used only for Mars switchers.
For additional information, refer to the “Switcher Control Rulebook” appendix of the Party Line Control Maintenance Manual, Grass Valley part no. 04−043473−010.
Crosspoint Bus router − distribution switcher using the Grass Valley CROSSPOINT BUS protocol. This includes
Trinix, Venus, TVS/TAS−1000/2000/2001/3000, GS−400, SDR−400, and Mars. Also includes Concerto equipped with CRS−MC−C2 Controller Board.
DA board − digital audio processor for Saturn Master Control switcher.
DDE − Dynamic Data Exchange. A form of interprotocol communication that uses shared memory to exchange
data between applications.
delegation − use of a special control panel or supervisory display to restrict control of a specific VTR to a particu-
lar control panel or panels. The delegation process does not actually connect a control panel to a machine; rather, it allows the connection to be made using the normal machine linkage procedures. See also Linkage.
DHCP − Dynamic Host Configuration Protocol. Provides automatic TCP/IP configuration when a DHCP server is
present on the network.
Distributed routing − sending a switch command through a CM 4000 running AccuSwitch, to a CM 4000 run-
ning JupiterXPress or a VM 3000 running JupiterPlus, and then to a router. Also called switch forwarding.
DVB−ASI - Digital Video Broadcasting − Asynchronous Serial Interface.
downloadable panel − term used with older systems (CE 2200/PARTY LINE technology). Downloadable panels have
the ability to change display mnemonics and/or category/number button assignments, from a central com- puter. This is a standard feature with Jupiter.
DSP − digital signal processor.
Dune − ATM−based digital audio switcher built by LAWO. Discontinued in 2002.
DV board − digital video processor for Saturn Master Control switcher.
Glossary−3 CM 4000 Installation and Operating Manual

DVS − (Philips) Digital Video Systems. Successor to BTS. Now part of Grass Valley.
EBU − European Broadcasting Union. Internet address: http://www.ebu.ch/
ES 400 − A term used in Grass Valley technical publications to denote the original asynchronous (non−reclock-
ing) version of the Venus digital audio switcher matrix board and associated components.
ES 401 − A term used in Grass Valley technical publications to denote the new AES11 synchronous/asynchronous
version of the Venus digital audio switcher matrix board and its associated components.
ES 3000 ESnet Interface Circuit Card − Ethernet board used in PC compatible computers. No longer available.
ESbus − nickname for EBU/SMPTE RS−422 bus protocol for remote control of television production equipment
using a full−duplex four−wire, asynchronous serial, 38.4 kbits/s digital channel. Connectors are 9−pin D. In- corporates ANSI−SMPTE 207M and Recommended Practice 113. The Jupiter Serial bus is designed to be compatible with ESbus; however, the serial data cable supplied by Grass Valley uses only 5 conductors. (In Jupiter systems, “ESbus” usually refers to VTR control.)
ESbus Routing Switcher Protocol − used for control of a routing switcher with a third−party computer operat-
ing according to the proposed ESBUS routing switcher dialect. Also referred to as ESCONTROL protocol. Uses logical input and output numbers to identify crosspoints.
ESbus Tributary protocol − (a.k.a. “ESTR” and “ES−trib”). Full tributary ESBus automation protocol, com-
pliant with SMPTE EG 29−1993, and all associated normative references. The protocol supports all standard bit rates from 300 to 115.2 kBPS. Flow control is an advantage with this protocol.
EScontrol − control of a “remote” (serial control) routing switcher using proposed ESBUS ROUTING SWITCHER PRO-
TOCOL. Also referred to as “ESbus Router” protocol.
ESnet − nickname for EBU/SMPTE proposed protocol for remote control of television production equipment
based on THIN NET.
ESphysical − (a.k.a. “ESP”). Used for control of a routing switcher with a third−party computer operating ac-
cording to the proposed ESBUS ROUTING SWITCHER PROTOCOL. Uses physical input and output numbers to iden- tify crosspoints.
ESswitch protocol − (a.k.a. “ESW”). Protocol used for Jupiter control of a routing switcher by a third−party com-
puter. It is described in Grass Valley document “ESswitch Serial Routing Switcher Control Protocol, En- hanced Version.” This is a simplified version of the ESBUS ROUTING SWITCHER PROTOCOL. This protocol oper- ates in a “pre−selected” mode, and no polling or flow control is implemented.
exclusion − lockout of selected inputs from selected outputs. Example: lockout of a test signal from bus leading to
transmitter.
extended party line − see PARTY LINE.
extended crosspoint bus − see CROSSPOINT BUS.
fabric board − DM−33100 matrix board used in Trinix router.
Glossary−4 CM 4000 Installation and Operating Manual

file server − a computer dedicated to providing access to a hard disk on a LAN. In Jupiter systems, the PC that holds
the Jupiter installation with the active set.
follow switch − a switch made automatically on one level in response to a switch made by the operator on another
level. See also AFV, REVERSE SWITCHING.
force unprotect/unlock − a system management function that allows a new source to be selected for a protected
or locked destination. See LOCK, and PROTECT.
FPGA − Field Programmable Gate Array.
full−matrix control − ability to select any source for any destination.
gateway − a device for connecting two dissimilar networks.
GUI −Graphical User Interface. In Jupiter systems, a “software” control panel that exists only as a CRT display.
hardware address −another name for the link level address, a unique identifier required for every device that
operates on a network (for example, 08000090acf6 [hex]). Compare with TCP/IP ADDRESS.
ICS − Integrated Control System. Original name of BCS 3000 and Jupiter Control Systems. “ICS” also refers to a
control system developed by Philips BTS Darmstadt.
indirect status instruction − see PRIMARY STATUS INSTRUCTION.
interface bus − an ESBUS term for the channel that connects VTRs, control panels, bus controllers, etc. Uses
9−pin D connectors (but Grass Valley version uses only 5−conductor cable). See SERIAL BUS.
JNIA - Jupiter Network Interface Application. A program that supported operation of a Logger, Log Viewer,
Party Line Download software, Physical Control (Switching), CP 3200, and Force Unprotect/Unlock. Super- ceded by JNS.
JNS - Jupiter Network Suite. A collection of many programs designed as a replacement and enhancement to the
JNIA software. Includes the Router Save/Restore Utility, Physical Diagnostic Utility, Physical Remapping Utility (PRU) and the I/O Editor. The JNS also includes all the JNS SERVERs, Board Status Display, Router Control Utility, JNS Logger, JNS Log Viewer, Force Unlock, Physical Control, and Party Line Download.
JNS Servers − JNS programs that provide data to Jupiter client programs in the same or other computers.
Jupiter - compact, follow−on version of BCS 3000 CONTROL SYSTEM. A PC-type computer is used as the file server.
Jupiter XPress - Provides a limited set of Jupiter switching and machine control functions using the CM 4000 as
the interface between Grass Valley crosspoint bus routers and certain control devices.
Lawo AG − audio equipment manufacturer based in Rastatt, Germany. Supplied components for Dune Digital
Audio Switcher.
level − historically, a switcher matrix that carries one type of signal, as determined by DIP switch settings on
crosspoint boards. Example: level 1 for video, levels 2 and 4 for left and right audio, etc. However, in 3−stage switching systems this switch−set level is referred to as the “physical” level; and large systems may require more than one physical level to provide enough hardware for an entire “logical” level (such as video). The Jupiter Physical Switching menu refers to a “logical level” that is actually the logical level number, this being the row number on which the level is identified on the Switcher Level Descriptions table. The logical level name also appears on this table.
Glossary−5 CM 4000 Installation and Operating Manual

linkage − the Jupiter machine assignment function, whereby control of a VTR is passed to a remote panel. The
system can be configured so that linkage will occur automatically, based on the signal from the VTR being switched to a destination associated with that panel; this function is sometimes described as “machine control following the router.” Linkage can also be accomplished manually, using the MC−3020L Linkage panel. See also DELEGATION.
Little Cloud − engineering project name for JUPITER XPRESS product.
lock − 1. on Jupiter control panels equipped with a LOCK button (except MC 3020L): after a given source has
been switched to a given destination, and LOCK is pressed, the source for that destination can then be changed only at the panel which set the lock; and only after LOCK is pressed again. Note that a panel can only lock
LEVELS that are assigned to the panel during configuration. See PROTECT, and FORCE UNPROTECT/UNLOCK. 2. on the MC 3020L Linkage panel, the LOCK button is used to prevent any interruption in the assignment of a machine to a control panel.
logical level mapping - in these systems, the same physical level number can be used on more than one logical
level. For example, you could have a switcher with Left Audio on level 2, and with Right Audio also on level 2. This technique can sometimes help reduce overall switcher size, but it requires special entries to control sys- tem tables.
logical level name − see LEVEL.
logical level number − see LEVEL.
logging − maintaining a disk file of Jupiter LAN activity, including switches, machine control commands, config-
uration set downloads, error messages, etc. Each file covers a twenty−four hour period.
LOS − Loss of Signal.
MADI − Multiplexed Audio Digital Interface. Interface bus used in Dune switchers.
matrix bus − see CROSSPOINT BUS.
M board − CE 3000 Matrix Controller. Now obsolete.
MDI − Multiple Document Interface.
MIDI − Musical Instrument Digital Interface. Serial interface bus used in Triton switchers.
mnemonic − abbreviation, usually four characters long, for a particular input or output. Mnemonics appear in the
LED status windows of the control panels. However, the term is sometimes used to define an input or output in the sense of a logical device name.
MPK − message−per−keystroke. Protocol developed by Grass Valley for control panels and devices connected
to the Jupiter Serial bus. Baud rate is variable, with 8 data bits, 1 start bit, 1 stop bit, and even parity; timeout is 6 characters (1.72 msec). See also SERIAL BUS.
native protocol − GV Series 7000 Signal Management System Protocol via RS−232, RS−422, SLIP, or Ethernet.
In Jupiter systems, used for control of a Grass Valley SMS 7000 or Encore control system (which is in turn connected to a routing switcher).
Glossary−6 CM 4000 Installation and Operating Manual

NetBEUI − NETBIOS Extended User Interface. Windows for Workgroups ships with the NetBEUI protocol to
interconnect computers running Windows for Workgroups, MS−DOS, Windows NT, and Microsoft LAN Manager−compatible networks, in a local area network environment. NetBEUI is a small, efficient protocol designed for use on a departmental LAN of 20 to 200 workstations. For enterprise−wide networks where a routable protocol is required, TCP/IP or IPX should be used.
NetBIOS − Network Basic Input/Output System. An operating system interface for application programs used
on IBM personal computers that are attached to a LAN.
node − a device on a network, such as a controller board, control panel, file server, or VTR.
numeric mode − switcher selection method using input and output numbers only (as opposed to
category/number mode).
numeric set − a factory−supplied configuration set used to set up and operate the routing switcher in the mini-
mum possible time.
override − one−button selection of an input. Override button of a control panel is programmed to select a
particular input that is used heavily.
output monitoring − feature of routing switcher which allows control system to verify switcher performance
without interrupting normal operations. A separate, internal switching system is used to switch the Monitor Output to any output of the switcher.
party line − proprietary network technology originally developed by TELEMATION, Inc. to control distribution
switchers. Uses unterminated 75−ohm coaxial cable from CE 2200 or PL 3000 looped through all control panels. Not to be confused with 50−ohm THIN NET technology used in Jupiter. Two types are commonly in use: the extended party line, which allows control of 250 inputs and 150 outputs; and the super party line, which allows control of 250 inputs and 250 outputs.
path finding − a switching technique allowing two or more TVS/TAS−2000 or later routing switchers to operate
as a system, where each switcher can access the other’s inputs through a number of tie lines. Because the tie lines are limited, the path will be blocked when all lines are busy. Not to be confused with THREE−STAGE
SWITCHING.
PCI − Peripheral Component Interconnect, a local computer bus standard developed by Intel Corporation. Most
PCs include a PCI bus in addition to a more general ISA expansion bus.
Philips Broadcast − successor to Philips Digital Video Systems (DVS). Now part of Grass Valley.
physical level − see LEVEL.
PL board − PL 3000 Party Line Interface. Now obsolete.
PMEM − battery−protected memory.
polling − communication technique where central controller polls (addresses) each device on a party line in turn.
When so addressed, a particular device can then send or receive data without being interrupted.
Glossary−7 CM 4000 Installation and Operating Manual

polling name − a unique address assigned to a switcher control panel. When transmitted by the polling and
control card, allows communication between that panel and the switcher matrix.
PPM − peak program meter.
protect − on Jupiter control panels with a PROTECT button: after a given source has been switched to a given
destination, and PROTECT is pressed, the source for that destination can then be changed only at the panel which protected the output. Note that a panel can only protect LEVELS that are assigned to the panel during configuration. See also LOCK, and FORCE UNPROTECT/UNLOCK.
primary status instruction − in Jupiter systems, a configuration technique used in the CP Input set for display of
SPLIT MNEMONICS. Indirect (“I”) entries are used to point to a primary (“P”) entry. The primary entry in turn points to the desired mnemonic for that level.
RCL − GV Router Control Language Protocol (Encore Control System Protocol via RS−232, RS−422, SLIP, or
Ethernet.)
refresh − continuous repetition of switching instructions and confirmation of crosspoint status. Reports any
interruption of service — for example, if crosspoint board is removed. When board is replaced, automatically restores previous switch instructions.
repeater − a device for connecting two LAN segments.
remote PC −a PC on a Jupiter LAN in addition to the PC used as the file server. Can be used for auxiliary tasks such
as remote LOGGING.
remote switcher −a non−Grass Valley distribution switcher under Jupiter control.
retained level − see STICKY LEVEL.
reverse switching −reverse switching is used in RS−232/422/423 data switchers where one level is used to switch
data from a controlling device (such as an editor) to a controlled device (such as a VTR); a second level is used to return data to the controller. The return path is switched automatically by the control system.
RS−422 − EIA standard which defines the electrical characteristics of balanced voltage digital interface circuits.
More rugged than the earlier RS−232 standard, which employs unbalanced voltages. This standard does not specify a connector type. While the Jupiter VTR / control panel bus and CC 2010 matrix (crosspoint) bus are both based on the RS−422 standard, the VTR / control panel bus uses 9−pin D connectors and the CC−2010 matrix bus uses 15−pin D connectors.
RS−422 bus − see SERIAL BUS.
S board − SC 3000 Serial Control Interface. Now obsolete.
salvo − single−command switching of source(s) to multiple destinations.
SCP − Software Control Panel.
segment − a portion of a LAN. In 10BASE2 systems, a segment is limited to 185 meters and 30 nodes. However,
segments can be joined by repeaters.
Glossary−8 CM 4000 Installation and Operating Manual

sequencing − term used in connection with Jupiter for single−command switching of one or more sources to one
or more destinations. With a CP 3000 switcher control panel, each named sequence can contain up to 25 switching events.
serial bus − term used in connection with Jupiter for the interface bus that connects VTRs and control panels to a
controller board such as a VM 3000. Depending on how the bus is configured by software, may also be re- ferred to as Sony bus, Ampex bus, ESBUS, MPK bus, RS−422 bus, etc.
server − 1. Hardware: a computer that provides shared services to other computers over a network; e.g., a file
server. 2. Software: a program that provides data to client programs in the same or other computers. In Jupiter systems, a “JNS server” (software) is said to run on a “file server” (hardware).
set − see CONFIGURATION SET.
single−bus control panel − selects any source for 1 destination.
SMPTE − Society of Motion Picture and Television Engineers. URL: www.smpte.org
Serial Digital Interface.”
SMPTE 269M−1999 − Television standard − “Fault Reporting in Television Systems.”
for Multiple Picture Rates.”
tems.”
SNMP − Simple Network Management Protocol.
Snowbird − engineering project name for JUPITER XPRESS product.
Sony bus − see SERIAL BUS.
SPD − signal presence detector.
SPDIF − Sony/Philips digital interface.
split − see BREAKAWAY.
status − in a distribution switcher, a display indicating what source is currently switched to a given destination.
sticky levels − control panel BREAKAWAY operation during which the selected LEVELS remain selected after a Take.
Sundance − engineering project name for CM 4000/ACCUSWITCH.
super crosspoint bus − see CROSSPOINT BUS.
Glossary−9 CM 4000 Installation and Operating Manual

super party line − see PARTY LINE.
switch forwarding − see DISTRIBUTED ROUTING.
TCS 1 −TELEMATION Control System. Predecessor to BCS 3000 and Jupiter. TCS 1 provides machine control only
(no switcher control).
TCS 2 − control panel protocol used with the MCS 2000 Master Control Switcher. Contains byte counts, check
sums, and error detection. Replaces the TCS CP interface but not the TCS MI interface. TCS2 can only be used with the MCS 2000, which must be equipped with updated PROMs.
TeleMation − Salt Lake City manufacturer of CATV and broadcast equipment founded by Lyle Keys and
associates. Now part of Grass Valley.
three−stage switching − architecture used for very large switchers as a means of reducing crosspoints needed for
a given number of inputs/outputs. An array of relatively small matrixes is arranged in an input stage, an inter- mediate stage, and an output stage. The path taken by a given signal through these stages is determined by software and will vary according to which circuits are already in use. Unlike PATH FINDING between two dis- crete switchers, three−stage switchers are carefully designed so that all inputs are always available at all out- puts; i.e., the switcher cannot be blocked.
tie line − see PATH FINDING.
tributary − term used in ESBUS documentation for an intelligent device (such as a VTR or control panel) con-
nected to an ESBUS.
TSL − Television Systems Ltd.
UMD − Under monitor display.
VDE − Verband Deutscher Electrotechniker e.V. (Union of German Electrical Engineers). Professional organiza-
tion in Germany authorized to conduct product safety tests.
VITC − Vertical Interval Time Code, embedded in the vertical interval of the video signal.
VGA Status Display − built−in switcher and machine control status display feature of the VM 3000. Can be
controlled by front−panel buttons or with optional VC 3020 panel.
VM 3000B − VM 3000 with minor electrical changes and “crescent” style front panel. Functionally identical to
VM 3000.
WPE − serial device type designation used for SPQ 3A frequency response equalizer connection to VM 3000.
XPT − crosspoint.
X−Y selection method − full−matrix control of switcher, where source is described as (x) and destination is
described as (y).
Y line − in an editing environment, some VTRs can act as controllers or tributaries. These can be connected with a
“Y” cable to two switcher ports— one for use when the VTR is a controller, the other when the VTR is used as a tributary. If the VTR is operated only as a controller, or only as a tributary, then a “Y” cable will not be needed.
Glossary−10 CM 4000 Installation and Operating Manual

ZIF − zero insertion force.
Zion − engineering project name for Jupiter “Configurator,” an enhanced, “Windows−like” editor introduced
with Jupiter 6.1.
Glossary−11 CM 4000 Installation and Operating Manual

Glossary−12 CM 4000 Installation and Operating Manual


BNC Tee cover, G−6
CM−4000/AccuSwitch application, G−8 Routing switcher protocol
Board Info/Control, JNS Control Center, 9−3
Command set, N−1 Hardware connections, 2−88 Level indication, 5−60 load factor, 1−18 Serial protocol table entry, 5−31
Board Override, 9−4 Board Status
JNS application, 8−1 JNS Control Center, 9−1
Assemble edit, MC−3000, 6−133 Assignable inputs. See Input Source Assignment
Break out panel, 2−8 Breakaway
Assigning machines to control panels, 5−141 Audio
CP−3000, 6−14 CP−3800, 6−41 CP−3808, 6−67 CP−3830, 6−81 , 6−94 defined, Glossary−2 Disabling, 5−59 Switching, 5−50
CP−3000 stereo switching, 6−18 CP−3800 stereo switching, 6−43 CP−3808 stereo switching, 6−74 CP−3830 stereo switching, 6−96 , 6−98 CP−3832/64 stereo switching, 6−115 GUI panel stereo switching, 7−14
Bridge, G−4 Broadcast Automation. See Thomson Automation Bulbs
Auto−Edit mode, 6−133 Automation
See also Thomson Automation Output passwords ignored, 5−57
Replacing, 2−58 Testing, 2−59 testing. See Diagnostics
AV board, defined, Glossary−1 AVS−1B. See Utah Scientific
B&B Electronics, 2−13 Backup, redundant CM. See CM redundant installation
Carts. See Audio carts
Base load factor, 1−17
Base multiplier, 1−21 Baud rate
Categories, Changing factory names for, 5−101 , 10−5 Category set
1200/2400 for MPK control panel, 5−33 entry on Serial Protocol table, 5−31
Changing, 5−105 default, 5−68 , 5−69 , 5−84 , 5−85 Category/number
BCS−3000, defined, Glossary−1 Belden
defined, Glossary−2 Linking to switcher input, 5−62 , 5−66 Linking to switcher output, 5−78 , 5−81
8723, 2−63 9505, 2−4 Binary
Mars protocol, 5−43 SDR−400 protocol, 5−43 super crosspoint bus, Glossary−2 Venus protocol, 5−43
CB−3000, 1−2 , 2−3 , 2−6 , 2−87 , G−2
LED error codes, R−1
Black Box, 2−25 , 2−62 , 2−90
CM 4000 Installation and Operating Manual Index−2

replacement CM, K−1 software configuration, 5−29 Reset, B−1 software version, 8−2 status check, 8−1 , 9−1 VGA display controls, 6−138 , A−1
CET, entry on Serial Protocol table, G−8
Characters, in set, table, & device names, 5−7 Cheapernet. See Thin net
Columbine Systems, G−2 Combiner. See VM−400 or DC−400
Chomerics, 2−7 , 2−64 Chop
Compiling/activating configuration set, 5−13 Computer, file server. See File server Concerto
CP−3000 panel, 6−13 CP−3020 panel, 6−26 CP−3800, 6−49 CP−3824 panel, 6−80 CP−3830 panel, 6−93 CP−3864, 6−103 defined, Glossary−2 limitations, 6−13
connection to CM, 2−3 connector numbering, 5−56 Switcher Description table entries, protocol, 5−43 Configuration
CP−3800, 6−50 Editor, 5−1 JNS Control Center, 9−6 Sets
Clear Flash, Board Info/Control menu, 9−4
Activating, 5−13 Compiling, 5−13 Copying and selecting for editing, 5−10 defined, Glossary−2 General description, 5−8 Modifying and downloading, 5−8 naming rules, 5−7 Numeric, 5−11
Clear PMEM, Board Info/Control menu, 9−4
clearing battery−protected memory, B−1 clock, 2−64 Configuration Info and Set Upload, 13−1 connecting to
multiple Crosspoint Bus routers, 2−31 PC, 2−36 remote (third party) switcher, 2−11 connecting to router, 2−3 Controls, indicators, connectors, 1−9 defined, Glossary−2 devices per bus, max, 1−17 drawing, 1−10 entry on Net Description table, 5−27 Ethernet address, K−2 front panel codes, G−13 hardware installation, AccuSwitch, 2−87 , G−2 LED error codes, R−2 levels, max. no. of, 1−16 MAC address, K−2 Multiple
Configuration Info & Set Upload, 13−1
Connect, on JNS Control Console, 4−2
Contact information, ii Control
Center. See “Control Center” below Panels
See also model no. (“CP−xxxx”) baud rate, 5−33 Custom mounting, 1−15 I/O set editor, 10−1 Installing, 2−37 JNS Router Control Utility, 17−1 naming rules, 5−7 Operating, 6−1 Power supply, 1−15 Software Control Panel Suite. See Software Control
Switchers, 2−31 Units/levels, 5−37 Next key, 6−138 , A−1 Pending reboot, 5−15 Pin outs, serial ports, 2−63 Protocol table, 5−30 redundant installation, 2−8
CM 4000 Installation and Operating Manual Index−3

installation, 2−39 MPK table entry, 5−110 Operation, 6−2
Control Center, 5−8 , 5−13 , 9−1
clearing battery−protected memory, B−1 CM 4000 reset, B−1 VM/SI−3000 reset, B−1
CP− 310/6, CP output set entry, 5−83 CP− 320
AC power adapter, Q−1 categories, 5−69 , 5−85 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 custom category set, 5−101 diagnostics, 6−6 Front panel drawing, 2−40 general description, 2−40 installation, 2−40 key positions (diagram), 5−103 MPK table entry, 5−110 Operation, 6−3 CP− 328
Controller, VTR, DM 400B, 5−53
Controller board, defined, Glossary−2 Conversion
analog−digital, 5−181 RS−232/422 converter. See RS−232/422 converter Copying
Configuration sets, 5−10 CP Input set, 5−77 CP Output set, 5−80
Cover for BNC tee, G−6 CP
Category sets, 5−101 Input sets, 5−62
AC power adapter, Q−1 categories, 5−69 , 5−85 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 diagnostics, 6−6 general description, 2−40 installation, 2−40 Level Set entry, 5−59 MPK table entry, 5−111 Operation, 6−4 CP− 330
control panel types, 5−67 , 5−82 Level sets, 5−58 Output sets, 5−78 Override sets, 5−96 Sequence sets, 5−99
CP board, defined, Glossary−2
CP I/O Set Editor, 10−1
password, 10−2 CP− 300 Series
diagnostics, 6−6 DIP switches, 2−38 Installation, 2−38 Installing button labels, 2−58 load factor, 1−17 rear panel connectors, 1−12 CP− 300
AC power adapter, Q−1 assigning keys to inputs, 5−96 diagnostics, 6−6 dual bus mode, CP output set entry, 5−83 , 5−86 entry on MPK table, 5−109 front panel drawing, 2−41 installation, 2−41 MPK table entry, 5−110 Operation, 6−4 sticky levels, 6−3 CP− 330/6
AC power adapter, Q−1 assigning keys to inputs, 5−96 diagnostics, 6−6 front panel drawing, 2−38 installation, 2−38 MPK table entry, 5−110 Operation, 6−1 sticky levels, 5−108 , 6−1
CP output set entry, 5−86 diagnostics, 6−6 installation, 2−41 MPK table entry, 5−111 Operation, 6−5 CP−2002
CP− 3008, CP Category set type entry, 5−102 CP− 310
CP Category type entry, 5−102 general, 1−5 Load factor, 1−18 specifications, 1−12 CP−2002B
AC power adapter, Q−1 assigning keys to inputs, 5−96 CP Category set type entry, 5−102 CP output set entry, 5−82 , 5−86 diagnostics, 6−6 front panel drawing, 2−39
CP Input set type entry, 5−67 CP Output set table entry, 5−82
CM 4000 Installation and Operating Manual Index−4
Control Console, 4−1

CP Output set table entry, 5−82 CP−3010
2400 baud operation, 2−62 Audio switching modes, 6−18 CHOP button, 6−13 CP Category type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 custom category set, 5−101 custom mounting, 1−15 defining
See also CP−3000 expansion panel or MC−3000 ex-
pansion panel Front panel drawing, 6−131 Load factor, 1−17 MPK Devices table entry, 5−107 With CP−3000
Front panel drawing, 2−42 General description, 2−42 Operation, 6−24 Permanent output assignment, 5−79 , 5−84 with MC−3000 machine control panel, operation,
override keys, 5−96 overrides (at panel), 6−21 sequences, 5−99 Diagnostics, 6−20 Display ID, 6−21 Entering mnemonic for switcher input, 5−62 Expansion panel
6−131 Work sheet for output set, M−1 CP−3020
assigning keys to inputs, 5−96 Chop button, 6−26 Front panel drawing, 2−43 General description, 2−43 Installing button labels, 2−58 Load factor, 1−17 Lock button, 6−26 MPK Devices table entry, 5−107 Operation, 6−26 Rear panel connectors, 1−12 Selecting output for control, 5−112 CP−3021
entry on Machine Control table, 5−140 Level statused, 5−59 Front panel drawing, 2−42 Full matrix control, 5−112 General description, 2−42 Input selection, 6−8 Installation, 2−42 key positions (diagram), 5−103 LEV button, 6−14 Level mnemonics, 5−59 Levels order in status row, 5−59 Linking category/no. to switcher inputs, 5−62 Load factor, 1−17 LOCK key, 6−11 MENU key, 6−15 modem connection, 2−62 MPK Devices table entry, 5−107 Multi bus control, 5−112 operation, 6−7
Front panel drawing, 2−43 General description, 2−43 Installation with CP−3020, 2−43 Installing button labels, 2−58 Load factor, 1−17 Rear panel connectors, 1−12
CP−3030, MPK devices table entry, 5−108
CP−3300, defined, Glossary−2 CP−3310
force unprotect/unlock, 6−12 tutorial, J−1 Output to control, changing, 6−20 Override input selection, 6−7 password, 6−22 PROTECT key, 6−9 re−legendable button kit, 5−101 Rear panel connectors, 1−12 Sequences (selecting), 6−17 Single bus control, 5−112 Status checking, 6−16 stereo special switching, 6−18
CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 defined, Glossary−2
CP−38 xx series, 64 level limitation, 1−17 CP−3800
Audio control mode, 6−43 baud rate set, 6−47 breakaway switch, 6−41 button lamps, brightness, 6−48 chop, 6−49 configuration, 6−50 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 CP Override table entry, 5−96
Switcher description table entry, 5−43 tutorial, J−1 Unlock, 6−11 Unprotect, 6−10 Work sheet for output set, M−1 CP−3008
CP Input set type entry, 5−67
CM 4000 Installation and Operating Manual Index−5
CP−3320, defined, Glossary−2

custom category set, 5−101 diagnostics, 6−47 display ID, 6−47 entry on Machine Control Devices table, 5−140 entry on MPK devices table, 5−108 error codes, R−12 front panel drawing, 2−44 installation, 2−44 Level button, 6−41 level selection mode, 6−41 Load factor, 1−17 lock, 6−61 machine control, 6−45 Menu mode, 6−45 modem connection, 2−62 Multiple destination mode, 6−31
installation, 2−45 key positions (diagram), 5−104 load factor, 1−17 lock, 6−69 MENU key, 6−68 modem connection, 2−62 operation, 6−64
force unprotect/unlock, 6−70 , 6−71 output to control, changing, 6−65 password, 6−75 power requirements, 1−13 PROM version, 6−47 , 6−71 , 6−113 , 6−121 protect, 6−70 rear panel connectors, 1−13 Status checking, 6−69 stereo special switching, 6−74 unlock, 6−69 unprotect, 6−70 with Expansion Panel, entry on MPK table, 5−109 CP−3809
changing output soft key, 6−34 erasing an output, 6−35 making a switch, 6−32 permanent output assignment, 5−79 , 5−85 switching to single destination mode, 6−37 operation, 6−27 override mode, 6−53 overview, 6−27 passwords, 6−51 power requirements, 1−12 prompting, 6−51 protect, 6−61 rear panel connectors, 1−12 Sequence mode, 6−57 Single destination mode, 6−37
button assignment, 5−79 diagnostics, 6−125 entry on MPK Devices table, 5−109 , 5−111 front panel drawing, 2−48 installation, 2−48 load factor, 1−17 operation, 6−124 power requirements, 1−13 rear panel connectors, 1−13 With CP−3808/3830, Permanent output assignment,
making a switch, 6−40 selecting an output for control, 6−38 split switch, 6−41 stereo special switching, 6−43
assigning buttons to outputs, 5−79 , 5−85 diagnostics, 6−130 entry on Machine Control table, 5−140 entry on MPK Devices table, 5−109 , 5−111 , 5−131 front panel drawing, 2−54 general description, 2−54 hardware installation, 2−54 load factor, 1−17 operation, 6−126 power requirements, 1−13 rear panel connectors, 1−13
Switcher description table entry, 5−43 sticky displays, 6−50 tie line status, 6−63 VTR control, 6−45 CP−3808
audio switching modes, 6−74 baud rate set, 6−72 breakaway (split switch), 6−67 button lamps, brightness, 6−72 categories, 5−69 , 5−85 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 custom category set, 5−101 diagnostics, 6−71 display ID, 6−72 displaying address (ID), 6−71 error codes, R−12 front panel drawing, 2−45 input selection, 6−66
CP−3810L, entry on MPK table, 5−108 , 5−132 CP−3810S
entry on MPK table, 5−108 , 5−131 operation, 6−126 CP−3824
categories, 5−70 , 5−85 category keys (diagram), 5−104 CHOP button, 6−80 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 custom category set, 5−101
CM 4000 Installation and Operating Manual Index−6

diagnostics, 6−87 displaying address (ID), 6−87 front panel drawing, 2−46 installation, 2−46 LEVEL button, blinking, 6−84 load factor, 1−17 LOCK key, 6−79 MENU key, 6−87 operation, 6−76
audio switching modes, 6−115 button lamps, brightness, 6−114 , 6−122 CP Category set type entry, 5−102 CP Input set type entry, 5−67 , 5−82 diagnostics, 6−112 displaying address (ID), 6−112 entry on CP Input set table, 5−68 , 5−83 entry on MPK table, 5−109 front panel drawing, 2−49 general description, 2−49 hardware installation, 2−49 LEVEL button, blinking, 6−102 load factor, 1−17 MENU key, 6−112 modem connection, 2−62 multi−panel applications, entry on MPK table, 5−127 operation, 6−100
force unprotect/unlock, 6−79 , 6−80 overrides, 6−77 power requirements, 1−13 PROTECT key, 6−79 rear panel connectors, 1−13 sticky levels, 6−83 unlock, 6−79 unprotect, 6−79 CP−3830
force unprotect/unlock, 6−104 , 6−105 Panel name, 6−112 password, 6−100 power requirements, 1−13 PRESET button, blinking red, 6−101 PROT/LOCK button, 6−103 , 6−104 rear panel connectors, 1−13 stereo special switching, 6−115 sticky levels, 6−102 unlock, 6−104 unprotect, 6−103 X−Y operation, entry on MPK table, 5−110 , 5−111 CP−3832L
audio switching modes, 6−96 , 6−98 baud rate set, 6−72 , 6−113 , 6−122 button lamps, brightness, 6−72 categories, 5−70 , 5−85 CHOP button, 6−93 CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 custom category set, 5−101 diagnostics, 6−71 , 6−97 display ID, 6−72 displaying address (ID), 6−97 dual / dedicated output, 5−111 , 5−126 , 6−89 error codes, R−12 front panel drawing, 2−47 installation, 2−47 key positions (diagram), 5−104 load factor, 1−17 LOCK key, 6−92 MENU key, 6−96 modem connection, 2−62 operation, 6−88
diagnostics, 6−121 entry on CP Input set table, 5−68 entry on MPK table, 5−109 general description, 2−49 hardware installation, 2−49 operation, 6−117 password, 6−117 PROT/LOCK button, 6−119 CP−3864
assigning keys to inputs, 5−62 audio switching modes, 6−115 baud rate set, 6−113 , 6−122 button lamps, brightness, 6−114 , 6−122 chop, 6−103 diagnostics, 6−112 displaying address (ID), 6−112 entry on CP Input set table, 5−68 , 5−83 entry on MPK table, 5−109 front panel drawing, 2−51 general description, 2−51 hardware installation, 2−51 LEVEL button, blinking, 6−102 load factor, 1−17 MENU key, 6−112 modem connection, 2−62 multi−panel applications, entry on MPK table, 5−127
force unprotect/unlock, 6−92 , 6−93 password, 6−75 power requirements, 1−13 PROTECT key, 6−92 rear panel connectors, 1−13 single bus control, entry on MPK table, 5−110 Status checking, 6−96 stereo special switching, 6−96 , 6−98 unlock, 6−92 unprotect, 6−92 with Expansion Panel, entry on MPK table, 5−109
CP−3830P, operation, 6−88 CP−3832
assigning keys to inputs, 5−62
CM 4000 Installation and Operating Manual Index−7

force unprotect/unlock, 6−104 , 6−105 Panel name, 6−112 password, 6−100 power requirements, 1−13 PRESET button, blinking red, 6−101 PROT/LOCK button, 6−103 rear panel connectors, 1−13 stereo special switching, 6−115 sticky levels, 6−102 unlock, 6−104 unprotect, 6−103 , 6−119 CP−3864L
Connecting to, 2−24 Physical level no., 5−42 protocol entry, 5−43 serial protocol table entry, 5−31
DCOM, I−4 , I−5 DD Series. See Diamond
diagnostics, 6−121 entry on CP Input set table, 5−68 entry on MPK table, 5−109 general description, 2−51 hardware installation, 2−51 operation, 6−117
Default linkage, 5−146 Delegate panel. See MC−3020D Delegation
force unprotect/unlock, 6−119 password, 6−117 PROT/LOCK button, 6−119
defined, Glossary−3 Group, Establishing, 5−149 Permanent, 5−149
Dependency, Standard tally, 5−158
DEST (CP−3800 button), 6−29 , 6−34 , 6−35 , 6−36 ,
6−38 , 6−42 Destination. See Output
load factor, 1−18 Transmission speed, 1−11 defined, Glossary−2
Deterministic switching, 1−3 , 2−3 , G−1
Device, name, rules, 5−7
Crosspoint bus, defined, Glossary−3
Crosspoint bus router, defined, Glossary−3
Diagnostic, physical, 15−1 Diagnostics
CP−300 series, 6−6 CP−3000, 6−20 CP−3800, 6−47 CP−3808, 6−71 CP−3809, 6−125 CP−3810, 6−130 CP−3824, 6−87 CP−3830, 6−71 , 6−97 CP−3832/3864, 6−112 CP−3832L/3864L, 6−121 MC−3000, 6−133 MC−3010, 6−137 Diamond
Cut and Paste, Windows to Jupiter, 5−6
D−2000/2166. See Datatek
DA board, defined, Glossary−3
CP Input set, 5−67 CP Level set, 5−59 CP Output set, 5−83 entry on MPK table, 5−123
Data bits, MPK, Glossary−6
CM 4000 Installation and Operating Manual Index−8

Hardware connections, 2−60 serial protocol table entry, 5−31 tally and DD−35, 2−67
EN Series (Jupiter LAN), 2−36
Encoder (8964), T−1 Encore
DIP switches, CP−300 Series panels, 2−38 Disable
Encore control of Jupiter, 2−91 Jupiter control of Encore, 2−17 MPK Devices table entry, 5−123 serial protocol table entry, 5−33 , Glossary−6
Breakaway, 5−59 Level, 5−59
Display mnemonic, defined, Glossary−6
Distributed routing, defined, Glossary−3 Distribution switcher. See Switcher, distribution
DM 400 Off Time, Switcher Description table, 5−47 DM−400/400A/400B. See Data switcher
CB−3000, R−1 CM−4000, R−2 CP−3800 series panels, R−12
Download, cable (CM to PC), 2−90
DST, G−11
DTK, 5−32
defined, Glossary−4 Max length, 1−11 Max tributaries, 1−11 Pin assignment, F−1 Protocol to Sony protocol, F−2 router, 5−32 Routing switcher dialect
Dubs panel (GUI), 7−22 Dune
defined, Glossary−3 entry on Serial Protocol table, 5−31
DV board, defined, Glossary−3
Control panel connections, 2−87 Matrix−physical level no., 5−42 serial protocol table entry, 5−33 Transmission speed, 1−11 tributary, 5−33 VTR, interface, 5−31
E−E monitor mode, MC−3000, 6−133 E−MEM. See Grass Valley
ESbus VTR Dialect, protocol guide, xxvi
EScontrol, protocol guide, xxvi
EMC, 2−36
defined, Glossary−4 Interface board. See ES−3000
EMI modifications, 2−7 , 2−64
CM 4000 Installation and Operating Manual Index−9

Fixed load factor, 1−18
See also ESbus routing switcher dialect load factor, 1−18 protocol guide, xxvi Routing switcher protocol, Hardware connections,
all outputs (JNS), 11−1 CP−3808, operation, 6−70 , 6−71 CP−3824, operation, 6−79 , 6−80 CP−3830, operation, 6−92 , 6−93 CP−3832/3864, operation, 6−104 , 6−105 CP−3864L, operation, 6−119 defined, Glossary−5 Router Save/Restore application, 18−2 VGA, operation, 6−140 VGA Status Display, Software configuration, 5−114 Forward switcher. See Data switcher
ESW, entry on Serial Protocol table, 5−33 , G−8 Ethernet. See LAN
defined, Glossary−4 Expansion panel
See also see model, e.g., CP−3010, CP−3809, etc. With CP−3000
Front panel drawing, 2−42 Operation, 6−24 with MC−3000
Frame advance, MC−3000, 6−133
illustration, 5−145 operation, 6−131
Frutiger, 2−58 FS−3000. See File server
Extended crosspoint bus, defined, Glossary−3
Full function machine control (GUI), 7−20
Extended party line, defined, Glossary−7
Extended Remote PC, I−4
Full function switcher panel (GUI), 7−11
Full−matrix control, defined, Glossary−5
G
Fair−Rite, 2−7 , 2−64
Generate VGA Files, A−2
Fast forward, MC−3000, 6−133
Getting Started guide, xxv , 2−1 , 3−1 , 5−1
GMT, G−11
FCS−3306, 2−62
GNP, 5−33
Ferrite, 2−7 , 2−64
GPI−T/CI, 2−23 Grass Valley
FF, front panel display, 2−7
Field Engineering Bulletin, 3−1
CP Category set type entry, 5−102 CP Input set type entry, 5−67 CP Output set table entry, 5−82 Model 200
File names, rules, 5−7 File server
Clock, 2−64 Configuration Editor, 5−1 customer−supplied, 1−14 defined, Glossary−5 disconnecting LAN, 5−21 Installation, 2−36 Printer. See Printer specifications, 1−14
MPK table entry, 5−123 serial protocol table entry, 5−31 Native Protocol, serial protocol table entry, 5−32 Group delegation panel. See MC−302D
GUI, defined, Glossary−5 GUI panels. See Software Control Panels
CM 4000 Installation and Operating Manual Index−10

Hardware, address, defined, Glossary−5
See also model number of product
HD 482 S1, xxxiii
Interface bus, defined, Glossary−5
Hexadecimal−decimal−binary chart, D−1 Horizon
IP address, network devices, 9−3
General Purpose Interface, connnecting to, 2−23 serial protocol table entry, 5−32
Horizontal Line, G−12 Hot key. See Shortcut key
Hyphen, in set, table, & device names, 5−7
entry on MPK devices table, 5−109 entry on Serial Protocol table, 5−33 manual, xxv stereo special switching, Switcher description table
I (entry on switcher input menu), 5−64
JNIA, defined, Glossary−5 JNS
I/O Set Editor, 10−1
on Remote PC, 4−1 Board Status, 8−1 Control Center, 5−8 , 9−1
ICS, defined, Glossary−5 ID
display on CP−3000, 6−21 display on CP−3800, 6−47 display on CP−3808, 6−72 display on CP−3830, 6−72
Board Info/Control, 9−3 Configuration, 9−6 Control Console, 4−1 CP I/O Set Editor, 10−1 defined, Glossary−5 Force Unlock/unprotect, 11−1 Logger and Log Viewer, 12−1 Physical Control, 14−1 Physical Remapping, 16−1 Router Control Utility, 17−1 Router Save/Restore, 18−1 Servers, defined, Glossary−5 TFTP Status, 9−2 Tools, 4−3 Utilities, 4−4
Image Video, TSI−100, hardware connection, 2−88
Indirect status instruction, 5−64
Input currently in use... (error message), 5−46 Inputs
JNS Console.ini, 4−2
Jog, MC−3000, 6−133 Jupiter
Entering # of, 5−51 Entering mnemonics for, 5−62 , 5−66 Entering name of, 5−51 Switcher Input table, 5−48
defined, Glossary−5 Network Interface Application. See JNIA Network Suite. See JNS XPress. See XPress
Inputs, Switcher, max no. of, 1−27 Insert
Jupiter XPress, defined, Glossary−5
CM 4000 Installation and Operating Manual Index−11

defined, Glossary−5 Disabling breakaway to, 5−59 Disabling switching on, 5−59 Mapping, 2−29 , 5−41 Max inputs/outputs, 5−38 max. no. of, 1−16 , 1−27 Physical. See Physical level Switcher Description table, 5−35
Limits, system, 1−17 Linkage
Default, 5−146 defined, Glossary−6 Machines to control panels, 5−141 Panel. See MC−3020L
L (flashing), on VGA display, 6−139
L4 (Venus level jumper), 5−39
Labels, preparing, 2−58 Lamps
Replacing, 2−58 Testing, 2−59 testing. See Diagnostics LAN
Local Security Policy, I−5
See also Unlock CP−3000 panel, 6−11 CP−3020 panel, 6−26 CP−3800, 6−61 CP−3808, 6−69 CP−3824, 6−79 CP−3830, 6−92 CP−3832, 6−104 defined, Glossary−6 GUI panel, 7−8
hardware, 5−27 , K−2
TCP/IP, 9−3 disconnecting file server, 5−21 installation
Log Viewer, JNS, 12−1
10Base2, G−4 use of non−Jupiter equip, 2−36 , G−3
Logging, defined, Glossary−6 Logical, Level
Laser compliance, xxxiii Lawo
Mapping, 2−29 , 5−41 Name, 5−35 Number, 5−35 Logical level mapping, defined. See level
See also Dune defined, Glossary−5
Logical level name, defined, Glossary−5
LED Error codes, CB−3000, R−1
Logical level number, defined, Glossary−5
Login, CP−3000 panel, 6−22
Logout, CP−3000 panel, 6−23
LEV key (CP−3000), 6−14 Level
breakaway, CP−3830, 6−81 , 6−94 button
Loss of power, 5−21
CP−3824, 6−84 CP−3832/3864, 6−102 CP−3800 button, 6−41
CM 4000 Installation and Operating Manual Index−12

Rear panel connectors, 1−12 MC−3020L
Button labels, 2−58 CP input set type entry, 5−67 CP output set entry, 5−82 Rear panel connectors, 1−12 MC−3040
M, in GUI status display, 7−15 M board. See CE−3000
MAC address, K−2 Machine control
CP−3800, 6−45 Devices table, 5−135 , 5−139 full function (GUI), 7−20 load factor, 1−18 slaved (GUI), 7−9
back panel drawing, 2−80 hardware overview, 2−77 reset switch, 2−79
MCS−2000, Machine control, Preroll key, 5−140 MCS−3500. See Saturn
Machine Control table, 5−139
MCS_TLY, 5−160 , 5−164 MCX 400. See 2x1 Matrix Combiner
Mains voltage selection, 2−1
Clearing battery−protected, B−1 clearing PMEM, B−1 MENU
Mapping, Logical level, 2−29 , 5−41
CP−3000 button, 6−15 CP−3800 button, 6−45 CP−3808 button, 6−68 CP−3824 button, 6−87 CP−3830 button, 6−96 CP−3832/3864 button, 6−112
Mark key, MC−3000, 6−132 Mars
connecting to VM−3000, 1−11 inputs/outputs table entry, 5−38 protocol selection, 5−43 Master control. See MCS−2000; Saturn Matrix
Back panel drawing, 2−80 GPI/O application (”MI−3040IO”), 5−115 Hardware overview, 2−77 in Saturn Tally systems, 2−69 MPK table entries, 5−115 Reset switch, 2−79 Software configuration, MPK devices table, 5−115 Tally, Hardware connections, 2−67 tally configuration (Standard tally), 5−152 , 5−158
Board. See Crosspoint board Bus, defined, Glossary−6 Cable, VDE modifications, 2−7 Matrix Combiner. See 2x1 Matrix Combiner
MC, 5−37 MC−200/900/2095/2098. See Alamar MC−3000
custom mounting, 1−15 Diagnostics, 6−133 Front panel drawing, 6−131 Load factor, 1−17 MPK Devices table entry, 5−107 operation, 6−131 Rear panel connectors, 1−12 Sony Auto−Edit, 6−133 MC−3010
MI−3040IO, 5−115 Microsoft programs. See name of program
MIDI, defined, Glossary−6 Mix
CP−3800, 6−44 CP−3808, 6−69 , 6−74 CP−3830, 6−96 , 6−98 CP−3832/3864, 6−112 CP−3832/64, 6−115 , 7−14
Diagnostics, 6−137 Front panel drawing, 6−135 , 6−136 Load factor, 1−17 Operation, 6−135 Rear panel connectors, 1−12 MC−3020D
Mnemonic, defined, Glossary−6 Mnemonics
Length, max, 5−62 Linking to switcher inputs, 5−62 , 5−66 Linking to switcher outputs, 5−78 , 5−81 Split, 5−64
Button labels, 2−58 CP output set entry, 5−82
CM 4000 Installation and Operating Manual Index−13

CP−3832/64 display, 6−115 , 7−14 NT. See Windows NT
Modem, connecting to control panel, 2−62 Monitor combiner. See VM−400 or DC−400
Monitoring, Venus, O−1 MPK
Baud rate, 5−33 Cable, 2−63 Installation, 2−37 Max devices, 1−17 Max length, 2−63 defined, Glossary−6 Devices, menu entry, 5−107
Mode, defined, Glossary−7 Set, 5−11
defined, Glossary−7 NVT. See Novotronic
Multimedia, Jupiter courses, xxv Multiple switcher installations
Hardware installation, 2−31 Path finding, 2−33 Statusing requirements, 5−79 Switcher levels table entry, 5−41 MVD. See Microvideo
Octal, Mars architecture, 5−38
Off Time, Switcher Description table, 5−47
Offset, 100/400 (switch. desc. table), 5−42
Offset from GMT, G−11
Name, rules for set, table, & device names, 5−7
On Monitor Display, T−1
On Screen Display, T−1
Native Protocol, Serial protocol table entry, 5−33
Online documentation, ii Option, Switcher Description table. See Data switcher
Native Protocol, defined, Glossary−6
Opto−isolator, Standard tally, 5−158
NetLink, 2−62 Network, board. See LAN card
Optoelectronic relays & optical couplers (MI/MC−3040),
Network description menu, 5−27 Network Suite. See JNS Nexus
Physical level no., 5−42 serial protocol table entry, 5−32 switcher protocol, 5−43
Oshino Electric, 2−58 Output
changing on CP−3000, 6−20 changing on CP−3808, 6−65 monitoring (Venus), O−1 Sets, 5−78
Nexus Star, Connecting to, 2−27
No Active Set, 4−2 , 7−6 , 10−2
Output monitoring, defined, Glossary−7 Outputs
defined, Glossary−7 Non−sequential path finding
Deleting from expansion panel, 6−24 , 6−125 Switcher, Entering mnemonics for, 5−81 switcher
Hardware installation, 2−33 Table entry, 5−185
NORM−L/R (CP−3800 display), 6−44 NORMAL
entering # of, 5−56 entering name of, 5−56 max no. of, 1−27 password levels, 5−57
CP−3808 display, 6−74 CP−3830 display, 6−98
CM 4000 Installation and Operating Manual Index−14

status checking, 6−16 , 6−69 , 6−96 Switcher Output table, 5−55 Override
auto analog−digital conversion, 5−181 defined, Glossary−7 Hardware installation, 2−33 locked groups, 5−182 multimedia course, xxv Non−sequential table entry, 5−185 Sequential table entry, 5−174 Three or more switchers, 5−178 VGA display, A−9
Board, 9−4 CP−3800, 6−53 defined, Glossary−7 Defining at CP−3000, 6−21 Input selection, 6−7 Sets, 5−96
Paths Full, message on GUI panel, 7−8 PC
as file server. See File server connecting to system controller, 2−36 remote unit, I−1
P (entry on switcher input menu), 5−64
connecting to LAN, 2−36 defined, Glossary−8 JNS applications, 4−1 PC−3000. See File server
P (flashing), on VGA display, 6−139 P board. See PL−3000
Page file name, 5−151
Pan Name, CP−3832/3864, 6−112
Pending reboot, 5−15 Physical
diagnostic, 15−1 Input number, 5−48 level
Parenthesis, in set, table, & device names, 5−7
Apex, 5−39 Datatek switcher, 5−42 defined, Glossary−5 ESbus switcher, 5−42 Nexus switcher, 5−42 RKX switcher, 5−41 Trinix, 5−38 Triton, 5−40 TVS/TAS, 5−41 Utah Scientific, 5−42 Venus, 5−39
Party Line, serial protocol table entry, 5−32 , 5−43 Party line
defined, Glossary−7 Utah Scientific, connecting to, 2−25
Party Line (UDI−1B), serial protocol table entry, 5−32 PASS =
CP−3808/3830, 6−75 CP−3832/3864, 6−100 CP−3832L/3864L, 6−117 Password
Physical Control, JNS, 14−1
Physical Remapping Utility, 16−1
and automation, 5−57 CP I/O Set Editor, 10−2 CP−3000, 6−22 CP−3808/3830, 6−75 CP−3832/3864, 6−100 CP−3832L/3864L, 6−117 Jupiter
Play key, MC−3000, 6−132 PMEM
after modifying tables, 5−27 defined, Glossary−7
Changing, 5−25 CP−3800, 6−51 General description, 5−22 levels
Polling and polling names, defined, Glossary−7
Post Mortem, 9−4 Power
Line (voltage) selection, 2−1
CM 4000 Installation and Operating Manual Index−15

Loss, 5−21 Supply, control panels, 1−15
R, in GUI status display, 7−15
Power adapter (AC), Q−1
PowerPoint, Jupiter courses, xxv
Re−legendable button kit, 5−101
Preroll, 5−140 , 6−132 , E−1
Primary status instruction, 5−64
Ready key, MC−3000 panel, 6−132 Reboot
Board Info/Control menu, 9−4 CM, B−1 minimizing downtime with CM, 5−15 Record
command on Compile window, 5−13 commands on Options menu, 5−21 hardware connection, 2−36
In key, MC−3000, 6−133 Mode key, MC−3000, 6−133 Out key, MC−3000, 6−132 Redundant, CM 4000. See CM 4000 redundant installa-
Probe connector and cable, C−1 Production switcher. See Switcher, production
PROMs, 1200/2400 baud for MPK control panel, 5−33
Relay descriptions (Standard tally), 5−152
See also Unprotect CP−3000, 6−9 CP−3800, 6−61 CP−3808, 6−70 CP−3824, 6−79 CP−3830, 6−92 CP−3832/3864, 6−103 CP−3832L, 6−119 CP−3864L, 6−119 defined, Glossary−8 GUI panel, 7−8
Relegendable button kit, 5−101
PC. See PC remote unit switcher, defined, Glossary−8 switcher (non−Crosspoint Bus), load factor, 1−18 switcher (third party), connecting to, 2−11
PS−300, Q−1
Retained level, Glossary−8 Retained levels. See Sticky levels
Punctuation, in set, table, & device names, 5−7
Reverse, CP−3832/3864, 6−112 Reverse switcher
See also Data switcher defined, Glossary−8
RFI modifications, 2−7 , 2−64
RGB switcher, Level menu entry, 5−42 RKX
Quick start manual, xxv , 2−1 , 3−1 , 5−1
Physical level no., 5−41
CM 4000 Installation and Operating Manual Index−16

RL11A, 2−38 Router. See Switcher, distribution
SDI to NTSC/PAL Encoder, T−1 SDR−400
Router Control Utility, 17−1
connecting to VM−3000, 1−11 Protocol selection, 5−43 Search
Router Save/Restore utility, 18−1
Mark, E−1 mark key
RP 1/2/3 UMDs, 2−82 RS−232/422 converter
control panel connection, 2−62 Utah Scientific connection, 2−25 RS−232/422/423, switching. See Data switcher RS−422
Cable, Connection to system controller, 2−63 defined, Glossary−8
Select, key, CP−3010, 6−134
RV, 5−37
Sequence sets, 5−99 Sequences
S
Sequencing, defined, Glossary−9 Sequential path finding
S (flashing), on VGA display, 6−139 S board. See SC−3000
Hardware installation, 2−33 Table entry, 5−174 Serial
S−T (on Swit. out menu), 5−56
Bus, defined, Glossary−9 CP Category set type entry, 5−102 CP input set type entry, 5−67 CP output set type entry, 5−82 Data cable, 2−63
Safe input, 5−46 , 5−47
Safe off time, Switcher Description table, 5−47
Safe time, Switcher Description table, 5−47 Safety
VDE modifications, 2−64 machine control, load factor, 1−18 MPK bus installation, 2−37 protocol table, 5−30
certification, xxxi terms and symbols, xxvii
Salvo panel (GUI), 7−26
Salvo, defined, Glossary−8 SATRN
CP Category set, 5−102 CP Input set, 5−67 CP Output set, 5−82 Saturn
Set mark key, 5−140
MC−3000, 6−132 Sets. See Configuration sets
connecting to Jupiter, 2−65 CP I/O Set Editor, with, 10−1 tally, 2−65
Setup, Router Save/Restore, 18−1
SB, entry on Net Description table, 5−29
CM 4000 Installation and Operating Manual Index−17

Slant, in set, table, & device names, 5−7
Source/destination panel (GUI), 7−24
Slashes, in set, table, & device names, 5−7
Space, in set, table, & device names, 5−7
Slaved machine control (GUI), 7−9
See also Under Monitor Displays and Jupiter software packages, 1−30 dimensions, 1−15 hardware installation, 2−81 ordering information, 1−23 software configuration, 5−116 specifications, 1−13
defined, Glossary−9 Mnemonics, 5−64 switching, 5−50
Slow motion play, MC−3000, 6−132 SMPTE
and Level menu entry, 5−42 CP−3000, 6−14 CP−3800, 6−41 CP−3808, 6−67 CP−3830, 6−81 , 6−94 CP−3832/3864, 6−101
259M−1997, defined, Glossary−9 269M−1999, defined, Glossary−9 274M−1998, defined, Glossary−9 292M−1998, defined, Glossary−9 EG 29−1993, G−8 EG 30−1995, G−9 ES LAN, G−9 ES tributary, G−8 SMS 7000
Spreadsheet, 5−6 Star. See Nexus
Start bit, MPK, Glossary−6
connecting to, 2−15 serial protocol table entry, 5−33 , Glossary−6
Start Board Override, 9−4 Status
under monitor. See SD−3x VG−3000. See VG−3000 VGA, A−1
See also VGA Status Display
Configuration Editor, 5−1 Installation, 3−1 upgrade, 3−1 version. See Version information
header table, 5−150 Multiple switcher installations, 5−79 Stereo
CP−3000 switching modes, 6−18 CP−3800 switching modes, 6−43 CP−3808 switching modes, 6−74 CP−3830 switching modes, 6−96 , 6−98 CP−3832/3865 status, 6−112 CP−3832/64 switching modes, 6−115 GUI panel switching modes, 7−14 Venus, Level jumper, 5−39
Software Control Panel Suite, 7−1
dubs panel, 7−22 full function machine control, 7−20 full function switcher panel, 7−11
audio switching modes, 7−14 license floppy, 7−1 salvo panel, 7−26 slaved machine control, 7−9 source/destination panel, 7−24 X−Y panel, 7−29 Sony
Sticky display (CP−3800), 6−50 Sticky levels
300 Series panels, 6−1 CP−3824, 6−83 CP−3832/3864, 6−102 defined, Glossary−9 entry on MPK devices table, 5−108
Auto−Edit mode, 6−133 machine control bus, 2−61
cable, 2−63 serial protocol table entry, 5−32 max VTRs per port, 1−18 Protocol to ESbus protocol, F−2 switcher protocol, 5−43
Stop bit, MPK, Glossary−6
Stop key, MC−3000, 6−132
CM 4000 Installation and Operating Manual Index−18

Streamline. See Grass Valley Super
Switcher, production. See specific model
Symbols, in set, table, & device names, 5−7 Sync
Crosspoint bus, defined, Glossary−3 Party line, defined, Glossary−7
Reference cable, 2−64 Vertical interval, 5−36
Syntax, naming rules for sets, tables, CPs, etc., 5−7
System limits, CM loading, 1−17
Switch forwarding, defined, Glossary−10
Switcher Description table, 5−35
Switcher Input table, 5−48
Switcher Output table, 5−55
Switcher, data matrix, 2−30 Switcher, distribution
Table names, rules for, 5−7
100/400 offset, 5−42 Alpha Image. See Alpha Image Datatek. See Datatek Disabling a level, 5−59 ESbus
TAKE key, Expansion panel, Deleting output from, 6−24
Take/select key (CP−3010), Machine control, 6−134
advanced (white paper), 2−67 and DD−35, 2−67 Example of operation, 5−172 Hardware connections, 2−67 multi−level (air+preview+iso)(red+yellow+green),
Physical level no., 5−42 Serial Protocol table entry, 5−32 Grass Valley. See Grass Valley Inputs
Entering mnemonics for, 5−62 Names, length of, 5−48 Microvideo. See Microvideo Multiple switcher installations
2−67 multimedia course, xxv output, 2−67 Saturn Tally, 2−67 software configuration, 2−70
Status, 5−79 Switcher levels table entry, 5−41 Nexus. See Nexus Novotronic. See Novotronic NVISION. See NVISION Output
MPK Devices table, 5−115 Relay Description table, 5−152 Tally Dependency table, 5−158 Tape
Drives. See HP 9144A (1/4 in) or HP 6400/2000 (DAT) Machines. See Audio carts or VTRs monitor mode, MC−3000, 6−132 TCP/IP. See IP address
Selecting on CP−3000, 6−20 Selecting on CP−3808, 6−65 outputs, password levels, 5−57 physical, input number, 5−48 Pro−bel. See Pro−bel RKX. See RKX serial connection, 2−11 Status
TCS−1/2, Serial protocol table entry, 5−32
Checking, 6−16 , 6−69 , 6−96 Multiple switcher installations, 5−79 Switcher Description table, 5−35 Switcher Input table, 5−48 Switcher Output table, 5−55 switching by physical connector number, 14−1 Triton, Connecting to, 2−13 Utah Scientific. See Utah Scientific
Television Systems Limited, S−1
CM 4000 Installation and Operating Manual Index−19

Switcher Description table entries
Installation, G−4 Part number, G−3 Test. See Diagnostics
audio/video/data, 5−44 level, 5−40 protocol, 5−43
TFTP, 9−2 Thin net
Probe connections, C−1 program restart, B−1 zipping a configuration set, 5−20 TSI−100. See Image Video
See also LAN Installation, G−3 ThinLAN. See Thin net Third party, routers
See also name of router manufacturer entry on Switcher Description table, 5−42
TSL−UMD, Serial Protocol table entry, 5−32
CP Input set entry, 5−72 CP Output set entry, 5−89 Switcher Initialization menu, 5−73 , 5−89
TVS/TAS−2000/3000, connecting to VM−3000, 1−11
Three−stage switching, defined, Glossary−10
Twisted pair, 2−5 , 2−63
Type 43 material, 2−7 , 2−64
defined, Glossary−10 status on CP−3800, 6−63 VGA display, A−9
AccuSwitch, G−2 , G−11 JNS Logger, 12−1
serial protocol table entry, 5−32
Time Standard table, G−11
Time Zone Name, G−11
Timeout, MPK, Glossary−6 Tools
See also Under Monitor Displays Defined, Glossary−10 UMD3A
Generate VGA Files, A−2 Zip/Unzip, 5−20
CP Category set type entry, 5−102 CP input set type entry, 5−67 MPK table entry, 5−108
Under Monitor Displays, 2−81
defined, Glossary−10 ESbus. See ESbus tributary VTR, DM 400B, 5−53 Trinix
bus loading, 1−17 CP input set type entry, 5−67 CP Level set type, 5−59 CP output set entry, 5−83 hardware installation, 2−81 MPK table entries, 5−116 permanent display, 5−122 software configuration, 5−116
and CB−3000, 2−6 connection to CM, 2−3 connector numbering, 5−56 Switcher Description table entries, protocol, 5−43 Switcher Description table entry, 5−38 Triton
Underscore, in set, table, & device names, 5−7
connecting to CM−4000, 2−13 connector numbering, 5−56 front−panel controls, not statused by Jupiter, 2−14 Serial Control Kit, 2−13 Serial Protocol table entry, 5−32
Universal Data Interface, 2−25 Unlock
CM 4000 Installation and Operating Manual Index−20

CP−3824, 6−79 CP−3830, 6−92 CP−3832/3864, 6−104 force, 6−12
bus loading, 1−17 Button labels, 2−58 Front panel, A−1 Installation, A−1 Rear panel connectors, 1−12
all outputs (JNS), 11−1 CP−3808, 6−70 , 6−71 CP−3824, 6−79 , 6−80 CP−3830, 6−92 , 6−93 CP−3832/3864, 6−104 , 6−105 CP−3864L, 6−119 VGA, 6−140 Unprotect
Cable modifications, 2−7 , 2−64 Defined, Glossary−10
Ventilation space, 2−2 Venus
CP−3000, 6−10 CP−3808, 6−70 CP−3824, 6−79 CP−3830, 6−92 CP−3832/3864, 6−103 CP−3864L, 6−119 force, 6−12
connection to CM, 2−3 output monitoring, O−1 stereo
CP−3000 switching, 6−18 CP−3800 switching, 6−43 CP−3808 switching, 6−74 CP−3830 switching, 6−98 CP−3864 switching, 6−115 , 7−14 Level jumper, 5−39 Switcher Description table entry, 5−36 , 5−38 , 5−39 ,
all outputs (JNS), 11−1 CP−3808, 6−70 , 6−71 CP−3824, 6−79 , 6−80 CP−3830, 6−92 , 6−93 CP−3832/3864, 6−104 , 6−105 CP−3864L, 6−119 VGA, 6−140
Version information, CM−4000, 8−2
Unqualified output (tally), 5−162 , 5−168
Software configuration, Status Display Headers table,
Update Board Info, Board Info/Control menu, 9−4
5−150 VGA Status Display
cable length, A−1 General description, 1−7 Generate Files command, A−2 hardware installation, A−1 operation, 6−138
Upload, Configuration, 13−1 Utah Scientific
serial protocol table entry, 5−32 switcher protocol, 5−43 physical level no., 5−42 UDI−1B Universal Data Interface, connecting to, 2−25
force unprotect/unlock, 6−140 Software configuration, A−2
Force unprotect/unlock, 5−114 Machine control table, 5−148 MPK devices table, 5−114 Status Display Headers table, 5−150 VGA Status Display table, 5−151 tie line (path finding), A−9 Video
Utah_12/96, Routing switcher dialect, Matrix−physical
level no., 5−42 Utilities
Physical diagnostic, 15−1 Physical Remapping, 16−1
display/generator. See VG−3000 Mode (VGA), 5−151 monitor combiner. See VM−400 or DC−400
V board. See VG−3000
Video Reference table, 5−190 , G−12
Downloading , configuration set, 5−13 , K−4
Validating configuration set, 5−13 , K−4
Variable play key, MC−3000, 6−132
CM 4000 Installation and Operating Manual Index−21

Voltage (AC line) selection, 2−1
X−Y panel (GUI), 7−29
VT_, serial protocol table entry, 5−33 VTRs
X−Y selection, defined, Glossary−10
Connecting to, 2−61 controlling with, CP−3800, 6−45 ESbus. See ESbus VTRs Linking to control panels, 5−141 Names, entering, 5−135
XCPU, 2−28 XP. See Windows XP
XPress, 1−3 , 2−3
key features, 1−27 , 1−28 , 1−29 , 1−30
Y
White paper, 2−67 Windows
cut and paste to Jupiter, 5−6 XP
Y line table, 5−189
Administrator login, 4−1 Remote PC, I−4 , I−5
Work sheet, CP−3000/3010 output set, M−1
CM 4000 Installation and Operating Manual Index−22

Table of Contents iii
CM VGA Options table H−1 CP category set table 5−101 CP input set table 5−62 CP level set table 5−58 CP output set table 5−78 CP override set table 5−96 CP sequence set table 5−99 Delegation groups table 5−149 Exclusion table 5−188 Machines table 5−135 Machine Control table 5−139 MPK devices table 5−107 Network description table 5−27 Non−sequential path finding data table 5−185 Passwords table 5−22 Path finding tables 5−174 Serial Protocol table 5−30 Status display header table 5−150 Switcher description table 5−35 Switcher input table 5−48 Switcher output table 5−55 Tally 5−152 VGA status display table 5−151 Y Line Table (DM 400/400A) 5−189
To access documentation for Apex, Saturn, Trinix, Triton, Venus, and related products, refer to the “Routing Products Documentation” CD− ROM, part no. 071−8274−xx.
For other Grass Valley Router products, including 7500, Concerto, and Encore, refer to the “Routing Products Documentation” CD−ROM, part no. 071−8130−xx.
Jupiter tables · Index Index−1
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| 00 | Advance to next code in sequence | p.652 | |
| 01 | Starting up the system | p.652 | |
| 0B | Initializing the bootp client | p.652 | |
| 0C | Initializing the control center client | p.652 | |
| 10 | Initializing the time keeper | p.652 | |
| 20 | Initializing the router status | p.652 | |
| 28 | Initializing the switch processor | p.652 | |
| 30 | Initializing the router switcher | p.652 | |
| 40 | Releasing application tasks to run | p.652 | |
| E0 | Shutting down the system | p.652 | |
| E4 | Suspending applications tasks | p.652 | |
| E8 | Abdicating control to slave board | p.652 | |
| F0 | Saving router status | p.652 | |
| F4 | Closing the switch log | p.652 | |
| F8 | Closing the event log | p.652 |
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Bootp failed: no vendor extensions. | p.656 | ||
| This message is logged when a bad bootp response is received. The bootp response must have ven- dor specific information to be useful. There may be another bootp server on the network erroneously configured to reply to this system. | p.656 | ||
| Bootp failed: no Jupiter extensions | p.656 | ||
| Bootp succeeded from server %s | p.656 | ||
| This message indicates that a good bootp response was received from the indicated server. | p.656 | ||
| Using configuration from %s for Bootp. | p.656 | ||
| A valid bootp response was not received. The indicated source is supplying the required information. | p.656 | ||
| Using bootline and defaults for Bootp. | p.656 | ||
| Activate command received−−updating code. | p.656 | ||
| The “activate” command was received. This is used to change the configuration set without reboot. However, the system will reboot if the new configuration set contains changes that requires it. | p.656 | ||
| Reboot command received−−rebooting | p.656 | ||
| The “reboot” command was received. This is used to reboot the system. | p.656 | ||
| Clear Persistent Memory command received−−memory will reinitialize on reboot. | p.656 | ||
| The “clear persistent memory” command was received. This is used to clear the router status on the next reboot. This has no immediate effect and any subsequent changes to router status will also be cleared on the next reboot. | p.656 | ||
| Post Mortem command received. Critical errors will not cause a reboot. | p.656 | ||
| The “post−mortem” command was received. This is used to tell the system to not reboot on a fatal error. The system tasks will be suspended so further investigation can be performed. | p.656 | ||
| Unsupported %s command received−−ignored. | p.656 | ||
| The system received an unsupported command. The system may be out of sync with the control cen- ter. The command is ignored. | p.656 | ||
| Scheduling system reboot | p.656 | ||
| Because the system is a high−performance system a requested reboot will be deferred till the system completes its high−priority tasks. This typically takes only a few seconds. | p.656 | ||
| Scheduling configuration swap | p.656 | ||
| Checking CRC of %s | p.656 |