Use and installation instructions carefully before installation and use
Keep this manual for future use.

Preparation for use
Security measures
Name of the components
Interior unit
External unit
Maintenance
Protection
Problems solved
Installation diagram
Select the best place for installation
Installation of the internal unit
Wiring diagram
Installation of the outside
Air purification 15
For the instructions for use of the remote control; see "Manuals Remote control."

On ensuring the normal use of the unit, read the manual carefully before installation, and try to install strictly according to this guide. Make sure that no air flows into the cooling system or coolant is discharged when moving the air conditioner. Properly ground the air conditioner into the earth. Check the connection of cables and pipes carefully, make sure they are correct and sturdy before connecting the air conditioner to the power supply. There must be an airflow break switch. After installation, the consumer must correctly operate the air conditioner according to this manual, and properly place it for maintenance and movement of the air conditioning in the future. Fuse or indoor unit: 3.15A 250V. For 9k,12k models ,fuse of outdoor unit: 15A 250V or 20A 250 V . For 18k models ,fuse of outdoor unit: 20A 250V . For 24k,30k,24k*;30k* models ,fuse or outdoor unit: 30A 250V . An earth leak switch (RCD) with a potential of above 10mAzal in the fixed wiring shall be included according to national regulations. Warning: Risk of electric shock can cause injury or death: Before maintenance disconnects all external electrical power supplies. The maximum length of the connecting line between the inner unit and the outer unit shall be less than 5 metres. It will affect the efficiency of the air conditioner if the distance is longer than this length. This device can be used by children aged 8 years and older, persons with limited physical, sensory or mental abilities or lack of experience and knowledge if they are under supervision or have understood instruction on the use of the apparatus in a safe manner and the hazards involved. Kids aren't allowed to play with the device. Neither cleaning and maintenance by the user should be performed by children without supervision. The batteries in the remote control must be recycled or discarded.Remove Old Batteries --- Please throw away your batteries as sorted household waste at the accessible collection point. If the device has fixed wiring, it must be equipped with power grid switching devices such as an external switch with a contact separation at all poles for full overvoltage decoupling, Category III, and these means should be included in the wired wiring rules., If the power cord is damaged, it shall be replaced by the manufacturer, dealer or similar qualified persons to prevent danger. The apparatus shall be installed in accordance with national wiring rules. The air conditioner shall be installed by professional or qualified persons. The device must not be installed in the laundry.

According to the nature of coolant (R410a,the value of GWP is 1975), the pressure of the tube is very high, so be careful when you start installing and repairing the device.
If the power cord is damaged, it must be replaced by the manufacturer or dealer or similar qualified persons to prevent danger.
The air conditioner shall be installed by a professional installer.
The temperature of the cooling circuit will be high, keep the interconnection cable away from the copper tube.
Before using the air conditioner, check and set up as follows.
Every time the remote control is replaced by new batteries or activated, remote control automatically prefers the heat pump.If the air conditioner you bought is a Cooling Only model, the heat exchanger can be used remotely.
Press and hold any button on the remote control to activate the backlight. It switches off automatically after 10 seconds.
The air conditioner has a auto restart function.
This device is made of recyclable or reusable material.Thank you must be in accordance with local waste disposal regulations.For the discard, make sure that the power cord is cut off so that it cannot be reused.For more detailed information about recycling this product please contact your local authorities who are involved in separate collections of waste or shop where you purchased the appliance.
Rejecting the device This apparatus complies with the European Directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).

This indication indicates that this product should not be disposed of with other household waste in the EU.To prevent potential environmental or human health damage by uncontrolled disposal, reuse it to promote sustainable re-use of raw materials.In order to deliver your used device, use the return and collection systemsor contact the store where the product was purchased. They can take this product back to allow it to be recycled environmentally friendly.

Symbols in this User Manual are interpreted as shown below.
Make sure not to.
Earthing is essential.
Pay attention to such a situation.


The above image is a simplified display of the unit; therefore, it may not match the one you purchased.


Display set temperature. It shows FC after 200 hours of use as reminder to clean the filter. After cleaning the filter press the filter reset button on the inner unit behind the front panel to reset the display.
This burns when the AC is in operation. It blinks during thawing
The shape and location of the switches and indicator lights may vary with different models, but their function is the same.


The shape and location of the switches and indicator lights may vary with different models, but their function is the same.


The shape and location of the switches and indicator lights may vary with different models, but their function is the same.


The shape and location of the switches and indicator lights may vary with different models, but their function is the same.


The shape and location of the switches and indicator lights may vary with different models, but their function is the same.


ON/OFF To make the AC function or stop by pressing this button.
The shape and location of the switches and indicator lights may vary with different models, but their function is the same.

Pull the plug off the socket.
It is recommended to clean the air filter after about 100 hours of work.
Turn off the device before pulling the plug out of the socket.
Clean it like this:
Turn off the device and remove the air filter.
To remove the front panel, pull it out as shown in image .
Wipe the device with a soft, dry cloth.
Use soft moisture cloth to clean the front panel if it is very dirty.
dry and soft cloth
to r
Some.
Never use volatile substances such as detergent or detergent to clean the device.
Replace the filter in the original positive after cleaning.
If the filter is very dirty, clean it with a solution of lukewarm water and a neutral cleansing agent. After cleaning, let dry well in the shade.
Never sprinkle water on the inner unit. Dangerous!Electric shock!
Close the front panel.
Replace the front panel and close it.
Clean the air filter every two weeks if the air conditioner is in a dusty environment is used.
Replace the front panel and close it by pushing it down as shown in the image "b."
Use a · shock! Electric Dangerous! · b b

The security device can be in the following cases: Unshoot and stop the device.
Install the air conditioner in a place that can keep the weight of the device so it can work more quietly.
Temperature of the outdoor air is higher than 24°C
Outside air temperature is lower than 10°C
Install the outdoor unit in a place where the blown-out air and sound of the device will not cause any discomfort to your neighbours.
Room temperature is above 27°C
Temperature of the outdoor air is higher than *43°C
Room temperature is less than 21°C
Do not place any obstacles to the external unit's air exit as they may influence the operation of the air conditioner and increase its noise level.
Room temperature is less than 18°C
* For tropical (T3) climate models, the temperature point is 55℃for 43℃.
The temperature of some products is allowed outside the range. In specific situation, consult the trader.
If the air conditioner in the COELEN or DRIOT mode works with door and/or window open The relative humidity is lower Then 80%, then dew drops down from the air exit.
The protective device shall enter into force in the following cases:
If you try to restart the unit immediately after it has stopped or after changing mode while the device was running; you need to wait 3 minutes. If you have connected the device to the power supply and turn it on immediately, honor and delay of 20 seconds may occur before the device starts operating.
If the device is completely stopped, press ON/OFF to restart it.The timer must be reset when cancelled.
Preheating
It takes 2-5 minutes to heat the evaporation device before heating at the beginning of the function, so that no cold air is blown out.
In the HEAR mode, the device automatically thaws to increase efficiency. This procedure usually takes 2-10 minutes. The fans stop while the temperature is thawing. After the thawing is complete, the device automatically returns to HEAT.

The following cases do not always have a possible defect, check them before asking for maintenance.
Is the security device or fuse jumped Wait for 3 minutes and start again. The protective device can prevent the unit from functioning Its batteries are almost empty Is the plug pulled out of the socket
Is the air filter dirty? Are the vents for air suction and air exit blocked? Is the temperature set correctly? Door or window open?
No cool or warm air
If there is strong interference (excessive static electrical discharge or power supply voltage abnormal) unplug the power supply and close it after 2-3 seconds.*
Device does not work immediately
If you change the control mode, there may be a 3-minute honour and delay.
This smell can come from another source such as furniture, cigarettes or other objects etc, which is sucked in by the apparatuses being blown out with air.
There's a peculiar smell
There is a sound of running water
Caused by the flow of coolant in the air conditioner.No reason for concern. Sound of defrosting in heating mode.
This is caused by expansion or reduction of the front panel due to temperature change.
A grinding sound can be heard
There's vapour coming out of the exit.
Fog appears when the air in the chamber gets very cold.This is due to the cooling air that is discharged from the inside unit during the COELEN or DROGEN Mode.
The compressor indicator lights on constantly, running indicator flashes and indoor fan stops.
The unit switches from the heating mode to thawing. The indicator lights up and returns to heating mode.
Device not working · Doesn't work directly · Does not work


Distance from wall must be more than 50mm
The distance from the floor shall be more than 2500mm
Distance of the air suction opening from the wall must be more than 250mm
The distance from the wall air suction opening shall be more than 250mm
The above image is a simplified display of the unit; therefore, it may be that does not match the unit you purchased.
The installation may only be carried out by qualified personnel, in compliance with local wiring requirements.

Choose a place where there are no obstacles at the air exit, and the air can be easily blown into any corner. Choose a place where pipes can be easily constructed and holes in the wall. Keep the required distance from the ceiling and wall according to the wiring diagram. The air filter should be easily removable. Keep the unit and remote control at least 1 m from television, radio etc. Away. Keep as far away from fluorescent lamps as possible. Do not place objects near the air-suction opening that could block them. Install on a wall that is strong enough to carry the weight of the unit. Install in a place that will not increase the sound and vibration of the operation. Keep away from direct sunlight and heat sources. Do not place combustible materials or combustion products on the top of the unit.
Lead length max.15 m
Install the outdoor unit in a convenient and well ventilated place; do not install the device where liquid gas could leak. Keep the required distance from the wall. The length of the pipe shall not exceed 15 metres. If it is longer than 5 meters, an additional amount of coolant of 20 grams per meter is required. The height difference between the interior and exterior unit shall not exceed 5 metres. If the outer unit is located in a higher position than the indoor unit, an elbow section in the pipe before the line enters it is necessary. Do not install the outdoor unit in a dirty or oily place, at an exit of volcanic gas or near a very salty beach. Avoid installing the device on the side of the road, where it could be soiled with mud water. Install the unit on a fixed support surface where the sound of the device is not enhanced in operation. Install the unit in a place where air exit is not blocked Avoid installation in direct sunlight,in and aisle or side exit,or near heat sources and fans. Keep away from flammable materials, thick oil and wet or uneven places.
Lead length max.15 m
Volume of charged coolant in unit for
Maximum difference in altitude H (m)
max. Line length
22K.24K
5 15 5 30
5 15 5 40
If the height and length of the pipes are outside the range of the table, please consult the trader.

Choose a place to install the mounting plate in accordance with the location of the inner unit and direction of the pipes.
Adjust the mounting plate perfectly horizontally using a level or perpendicular.
Drill holes of 32 mm deep into the wall to attach the plate. Insert the plastic plugs into holes and attach the mounting plate with tap screws. Check that the mounting plate is securely attached. Then drill a hole for the lead.
assembly plate, must be used to secure the mounting plate, others are prepared.
Sliding for wall hole (hard polyethylene tube prepared by the user)
Determine the position of the hole for the pipe in accordance with the location of the mounting plate.
Drill a hole in the wall. The hole should run slightly down to the outside.
Install a slider in the hole in the wall to keep it clean.
Attach the pipes (liquid and gas lines) and cables through the hole in the wall from the outside, or attach them from the inside after you have established the inner tubes and cable connections so that the outer unit can be connected to it. Determine whether the plastic part should be cut off, in accordance with the direction of the pipes (see below).
Sew the plastic part along the gutter
After you have properly connected the pipe, install the drain hose. Then connect the power cords. Pack the pipes, cables and drain hose together in thermal insulation material.

Heat insulation of the Connections of pipes: Wrap the joints of pipes with thermal insulation material and cover them with vinyl tape.
a.
Place the drain hose under the lead.
Mainline Thermal insulation tube
b.
Insulation material: polyethylene foam more than 6 mm thick.
Do not turn the drain line, let her protrude or swing around, do not immerse the end in water.
If a prolonged drain hose is connected to the drainage line, make sure that it is thermally insulated when you lead it into the inner unit.
Drain hose (user-prepared)
If the line is directed to the right, the pipe, power cord and drain line shall be thermally insulated and attached to the rear of the unit with a pipe clamp.
Small tube Pipe hose
Hook here Base Underplane Guide Clamp Subject Line
A. Connect the pipe clamp to the buckle. B. Press to hook the pipe clamp on the base.
a.
Connect the pipes of the inner unit using two wrenches. Note the permissible torque as shown below to prevent any damage to the pipes, connections and nuts.
b.
First, turn them by hand and then use the wrenches.
Torsie Moorwidth Min. thickness
Liquid side (φ6mm or 1/4 inch)
15~20N·m 17mm 0.5mm
Liquid side (φ9.53mm or 3/8 inches)
0.6mm
0.6mm
Gas side(φ9.53mm or 3/8 inches)
Gas side(φ12mm or 1/2 inch)
0.6mm
0.6mm
*For the unit of 12K* is larger than the unit 12K.For the one of 18K* it is greater than the one 18K.

Connecting the cable 4.
Connect the power cord to the inner unit by connecting one-to-one wires to the terminal on the switchboard in accordance with the connection of the external unit.
Attach the power cord to the switchboard with a cable clamp.
Use an approved circuit breaker for the model 24 K between
the power source and unit. A circuit breaker shall be fitted to ensure that all supply lines are adequately closed.
The images in this manual are based on the external display of a standard model.The result may be different from that of the air conditioner you have selected.
Use a separate circuit specifically for the air conditioner. For the wiring method, refer to the circuit diagram on the inside of the access door.
Check that the thickness of the cable corresponds to the specification of the power source.See table with cable specifications below.
Check the wires and make sure they are all securely attached after you have connected the cable.
Make sure to install an earth leak switch in a wet or damp environment.
Type of Normal Cross-section
2 1.0/1.5mm X4 2 1.0/1.5mm X3
H05VV-F H07RN-F 12K*
2 1.0/1.5mm X3
2 1.0/1.5mm X4
9K 12K H07RN-F H07RN-F
2 1.0mm X5 2 1.0 mm X3
18K H07RN-F
2 1.5mm X3 H07RN-F
2 1.5mm X5
H07RN-F 18K* 2 1.5/2.5MM X3 H05VV-F
2 1.5mm X4
24K 30K
2 0.75mm X4 2 2.5mm X3 H07RN-F
H07RN-F
24K* 30K* 22K*
H05VV-F
2 2.5mm X3 2 2.5 mm X4
H07RN-F
Attention: The plug must be accessible even after installation of the device in case there is a need to unplug it.If this is not possible, connect the device to a two-pole switch point with contact separation of at least 3 mm2 placed on an accessible location, even after installing.


Make sure that the colour of the wires of the outer unit and number of the clamp are the same as those of the inner unit.
For 9K*,12K*.18K* ,22K* and 24K* models, 30K* power supply is connected from the internal unit with a circuit breaker. For 9K,12K,18K,24K, 30K models, the power supply is connected from the outside unit with a circuit breaker.

Rubber path (optional) and location
below the bottom pedestal
The condensation water is discharged from the outside unit when the unit works in the heating mode. To avoid hindering your neighbours from protecting the environment, you need to install a drain gate and a drain hose to drain the condensation water. Just install the drain hose and rubber ring on the chassis of the outside unit, then connect a drain lang to the exit as the image strikes straight
Drain hose (user-prepared)
Install and attach the outer unit
Attach the unit with bolts and nuts firmly to a flat and strong floor.
If the unit is installed on the wall or roof, make sure that you attach it properly to prevent the unit from shaking during violent vibrations or severe wind.
External unit guidance connection
Remove the caps from the 2-way and 3-way valves.
Connect the pipes separately to the 2-way and 3-way valves, in accordance with required torque.
Cable connection of the external unit (see previous page)
Humid air in the cooling cycle can cause a malfunction of the compressor. After installing the indoor and outdoor unit, remove air and moisture from the cooling cycle using a vacuum pump as shown below.
Connect to the inner unit
(6) Open 1/4 stroke
(7) Rotate to fully open the valve
(7)Roar to fully open the valve
Connect to the inner unit
(8) Folding Valve cap

(1) Unscrew and remove the caps of the 2- and 3-way valves. (2) Unscrew the service valve cap and remove it. (3) Connect the flexible vacuum pump hose to the service valve. (4) Start the vacuum pump and let it run for 10-15 minutes until the pump reaches an absolute vacuum of 10 mm Hg. (5) While the vacuum pump is still running, close the low pressure button on the nozzle of the vacuum pumps. Then stop the vacuum pump. (6) Open the 2-way valve 1⁄4 stroke, and close it again after 10 seconds. Check the sealing of all compounds using liquid soap or an electronic leak detector. (7) Turn the 2 and 3-way valve handlebars to close the valves completely.Unplug the flexible vacuum pump hose. (8) Replace the caps of all valves and tighten them firmly.

Version No.1821054-01