USE INSTALLATION INSTRUCTIONS

TYPE AMW2

Thank you for buying this air conditioner. Please read these instructions carefully before installing and using this device, save it for later use.

Page 2 of the Hisense AMW3 user manual — CONTENTS
Page 2 · click to enlarge
Page 2

CONTENTS

OUTDOOR UNIT: AMW3-24U4SKC AMW4-28U4SAC AMW4-28U2SAC AMW4-28/H4SACE AMW4/36U4SAC AMV4-36U2SAC AMV3-24H4SAD1 AMW42-28U3SAD1 AMW4-36U3SAD2

For safety reasons, the following should always be observed

02

04

Selecting the installation location

05

05

Complete and test indoor/outdoor connections

10

13

Installation diagram & accessories · Installation outside unit · Flow chart coolant

Page 3 of the Hisense AMW3 user manual — WARNING
Page 3 · click to enlarge
Page 3

1. FOR SAFETY REASONS, THE FOLLOWING SHOULD ALWAYS BE OBSERVED:

Make sure that the air conditioner's electrical connection is connected to a separate group of devices not connected to other appliances. Read this chapter carefully before installing the air conditioner. Make sure you follow the warnings indicated, as they contain important safety issues. The indications and their meaning are as follows:

WARNING

Do not install the unit yourself (customer). A faulty installation can cause damage due to fire, electrical shocks, falling over the unit or water leakage. Consult the dealer whose unit was purchased or a specialist installer. Please install the unit carefully in a place that can carry the total weight of the unit. If the unit is installed in an insufficient position, it can cause falls and injuries. Use the required wiring to securely connect inside and outside units, and attach the wire firmly to the connection block of each part so that there is no voltage on the outside of the device. A faulty connection or attachment can cause fire. Do not apply intermediate connections in the power cable or connection cable and do not connect too many units to one group. This can cause fire or electric shocks due to faulty connections or insulation, exceedance of permissible power etc. Make sure that no cooling gas leaks after the installation is complete. If cooling gas leaks inside and this comes into contact with fire from a fan heater, space heater, oven, etc. harmful substances are released. Perform the installation safely in accordance with this installation manual. A faulty installation can cause personal injury due to fire, electrical shocks, falling over the unit or water leakage. Perform the electrical installation according to this installation manual and make sure to use a separate group. If the capacity of the circuit is insufficient or the electrical work is not carried out properly, then this could result in fire or electric shocks.

Show 11 more labels / short text on this page
Page 4 of the Hisense AMW3 user manual — CAREFUL
Page 4 · click to enlarge
Page 4

Carefully attach the cover cap of the internal unit electrics and the maintenance panel of the outer unit. If the cover cap of the internal unit and/or maintenance panel of the external unit is not carefully fixed, dust, water, etc. may be used to do so. fire or electric shocks. Make sure that while installing the electronic control card inside or wiring, the power is switched off. This could cause an electric shock. The apparatus shall be installed in accordance with national wiring requirements. Make sure that no substances other than the prescribed coolant (R401A) enter the cooling circuit when installation or movement of the unit. The presence of undesirable substances such as air can cause an abnormal rise in pressure or explosion.

CAREFUL

Get grounded. Do not connect the earth wire to a gas line, water pipe, lightning rod or telephone earth wire. A false grounding can cause an electrical shock. IDo not install the unit in a place where leakage of flammable gases can occur. If gas leaks and accumulates in the space around the unit, this could cause an explosion. Turn the nuts with a torque wrench, as indicated in this manual. If it is tightened too tight, the screw nut may break over time and thereby cause leakage of coolant. Install a leak protection depending on the location of installation (moist site). If no Earth leak protection is installed, this can cause an electric shock. Make sure that no cooling gas leaks after the installation is complete. If cooling gas leaks inside and this comes into contact with fire from a fan heater, space heater, oven, etc. harmful substances are released. Perform the installation of drains and pipework safely in accordance with this installation manual. If there is a fault in the drains or pipework, water can leak out of the unit and make your home furniture wet and damaged.

Show 10 more labels / short text on this page
Page 5 of the Hisense AMW3 user manual — SM AMW2 sheet 5
Page 5 · click to enlarge
Page 5
Diagram . .
Diagram . .

EXTERNAL DRIVER APPEAL THE Drain line for connecting the indoor and outdoor unit. (It is difficult to install the drain sleeve when the inner unit is mounted.) Connect the drain hose (available at a construction market, inside diameter 15 mm) as shown in the picture.

LET OP: Use in a cold surrounding the drain bend Not. This may freeze allowing the fan Stop.

• · •

Page 6 of the Hisense AMW3 user manual — 4.  INSTALLATION OUTSIDE UNIT
Page 6 · click to enlarge
Page 6

3. SELECT THE LOCATION OF INSTALLATION

EXTERNAL WHERE IT IS NOT TO BE EXPRESSED BY STRONG breeze. Where the airflow is good and contains little dust. Where it is not exposed to rain and direct sunlight. Where the neighbors are not disturbed by noise when working or hot air. Where a sturdy wall or support is present to prevent sound and vibration from being reinforced. Where there is no danger of the leakage of flammable gas. Where it is at least 3 m away from an antenna for radio or TV. The affected device may require an amplifier. Install the unit horizontally. Do not install the unit in a place where snowfall or bloated snow can affect. In areas with heavy snowfall, an awning, pedestal and/or several bulkheads shall be installed.

4. INSTALLATION OUTSIDE UNIT

CAREFUL

Avoid the following places for installation where air conditioner problems may occur. Where there is a lot of machine oil. Salty places like the seaside. Where sulphur gases occur like a hot water source. Where there is high-frequency or wireless equipment.

LET OP: If the air conditioner is to operate at low outside temperatures, make sure that the instructions described below are followed. Never install the outer unit in a place where the side of the air inlet/exit is directly exposed to the wind. Install the outside unit with the air intake side facing the wall to prevent wind exposure. It is recommended to install a re-shot for the air outlet side of the outer unit in order to prevent wind exposure.

Show 13 more labels / short text on this page
Page 7 of the Hisense AMW3 user manual — 4-1 REQUIRED FREE SPACE AROUND THE OUTER UNIT (IN MM)
Page 7 · click to enlarge
Page 7

4-1 REQUIRED FREE SPACE AROUND THE OUTER UNIT (IN MM)

LOCATION If there are barriers around the outer unit, then these obstacles must be distances to the external unit as shown in the pictures below.

Diagram . .
Diagram . .

(3) Only at the front (blowing) an obstacle. In this case, the rear side, both sides and top side must be open.

(4) Only on the front and rear side an obstacle. The unit can be used with a conductor for the blown air (both side sides and top side are open).

Diagram . .
Diagram . .

(5) Space for maintenance Keep the space for maintenance as shown in the picture below.

Page 8 of the Hisense AMW3 user manual — 4-3 INSTALLATION OF THE DRAIN CONNECTION
Page 8 · click to enlarge
Page 8

In the case of installation of the unit in a space closed to four sides such as a balcony, a distance exceeding 200 mm behind the unit shall be maintained as indicated. If there is insufficient air flow or the possibility of short-circuiting air, a conductor for blown out air shall be installed and sufficient space shall be kept behind the air intake.

WARNING

Do not use the drain connection in a cold environment. This can freeze the fan.

4.4 CONNECTION WIRING AND POWER CABLE OF EXTERNAL UNITS

LET OP: Never install multiple outdoor units sideways side by side.

Ensure that the power cable to the air conditioner meets the specifications in the table below and "technical standards for electrical installations." Make sure that a separate group is used for the air conditioner. Make the connection to a power switch with a contact opening of 3 mm or more and turn it off to interrupt main power supply. If the power switch is switched off, all phases must be interrupted. Main switch / fuse input capacity: 20 A

More than 100 mm

More than 100 mm

More than 350 mm More than 100 mm

More than 200 mm

Specification of power cable3-arterial cable 2,5 mm2, according to standard 245 IEC 57 Specification wiring connection inside and outside4-arterial cable 0,75 mm2, according to standard 245 IEC 57

Less than 1,200 mm from the front facade

4-2 INSTALLATION OF THE UNIT

At installation, secure the legs of the unit with bolts. Make sure that the unit is installed firmly so that it does not fall over by earthquake or wind.

WARNING

Mount an Earth leak protection in accordance with your installation. If no protection is fitted, there is a risk of electric shocks.

4-3 INSTALLATION OF THE DRAIN CONNECTION

Perform the drain pipe work so that it is discharged from one place.

Show 7 more labels / short text on this page
Window frame
Page 9 of the Hisense AMW3 user manual — 4-5 DIAGRAM ELECTRICAL WIRING
Page 9 · click to enlarge
Page 9

4-5 DIAGRAM ELECTRICAL WIRING

Diagram . .
Diagram . .

NOTE: Wiring scheme for multi-split and any regular Inner unit.

Diagram . .
Diagram . .
Page 10 of the Hisense AMW3 user manual — WARNING
Page 10 · click to enlarge
Page 10

WARNING

Make sure that the installation complies with "technical standards for electrical installations," follow this manual and use a separate group for the electrical installation. If there is insufficient capacity for the group or a deficiency in the installation, there is a risk of electrical shocks. There may be overvoltage, including for DC components. Make sure the right type to choose overvoltage protection.

Diagram . .
Diagram . .
1. Remove the screw from the cap of the connection block. 2. Connect the wiring and power cable to the connection block. 3. Carefully re-apply the cover cap.
Diagram . .
Diagram . .

WARNING Make sure that the cover of the valve is carefully attached in the outer unit, otherwise it can burn by dust or water or electric The Commission has already taken a decision on the matter. Use for connection of inside and outside unit wiring that meets the standards and attach it carefully to the connecting block, so that no force is applied to the connection block and device concerned. Inadequate connection or confirmation of the Wiring can cause fire. Make sure that the cap of the connection block is attached to inside and outside unit. If it is not confirmed correctly, there is a risk of fire or electrical shocks caused by dust or water penetration. Make sure the power cable is suitable for a current of 20 A or more, otherwise this may cause fire.

Show 4 more labels / short text on this page
Page 11 of the Hisense AMW3 user manual — 5.1 FLARE CONNECTION
Page 11 · click to enlarge
Page 11

5. FINISH AND TEST CONNECTIONS INSIDE/OUTER UNITS

CAREFUL

Use insulation material of the prescribed thickness. Too big thickness can cause incorrect installation and may not be too thick Condensation.

5.1 FLARE CONNECTION

* Keep the length of the pipe as short as possible. With larger pipe lengths, the capacity of the inner unit can be reduced.

Limit Type Guide length per inner unit Total line length for multi-system Height difference (Bi ~ Bu) Height difference

5.1 BLOWING UP The main cause of gas leakage is an error in the conjuring up. Execute the trumpeting correctly according to the following procedure.

20 m* 40 m 10 m 7,5 m

  • 1. Cut lead
  • Cut the copper pipe properly with the pipe cutter. 2. Remove Blackberries
  • Carefully remove all the blackberries from the cutting surface of the pipe.
  • Keep the end of the copper pipe down to prevent blackberries falling into the pipe. 3. Put the nut on the pipe
  • Take the nuts attached to the inner outer units and put them on the lead after all the blackberries have been removed. (After the conjuring up, this is no longer possible.)
  • The screw nut for an R410A line may differ from a R22 pipe depending on the diameter of the pipe. 4. Blow-up
  • Run the trumpeting with tools as shown below.

The test shall be performed in accordance with the requirements of paragraph 5.3. PIPE LENGTH AND HEIGHT DIFFERENCE

Length of leadMax. 15 mNo extra filling required Above 15 mNeed extra filling Coolant to be added15 g/m1(cooling line length -15 m)

DIMENSION If you use copper pipe trading stock, the following table must be used for specifications.

External diameterA (mm) Flare tool for R 410A clamp typeNormal flare tool Clip TypeWing nut type Ø 6,35 mm0 to 0.51,0 tot 1,51,5 tot 2,0 Ø 9.52 mm0 to 0.51,0 tot 1,51,5 tot 2,0 Ø 12.7 mm0 to 0.51,0 tot 1,52,0 tot 2,5 Ø 15,88 mm0 to 0.51,0 tot 1,5--
Diameter for outer unitWall thicknessInsulation thickness UNIT AVl. Gas pipelineØ 6,35 mm0,8 mm8 mm Ø 9.52 mm0,8 mm8 mm UNIT BVl. Gas pipelineØ 6,35 mm0,8 mm8 mm Ø 9.52 mm0,8 mm8 mm
Page 12 of the Hisense AMW3 user manual — SM AMW2 sheet 12
Page 12 · click to enlarge
Page 12
  • Hold the copper pipe firmly in the mould with dimensions as shown above. 5. Control
  • Compare the conjuring with the image below.
  • If the convoker is not fixed, cut off the part that has been hunched and run it again.

5-3 PIPE CONNECTION LET OP: Turn the screw with a torque wrench, as shown in the table indicated below. If it is tightened too tight, you can break the screw nut over time and thereby leak from coolant.

Not good Good o 90

1. Connection inside unit • Connect both the fluid line and gas pipe to the inner unit. - Apply a little cooling oil to the surface of the pipe that is being inserted. - For the connection, line up the middle of both pipes and slide them together, then turn hand on the first 3-4 blows of the screw nut. - For the attachment of the connection to the inner unit, use the table below as standard and tighten the screw with 2 keys. Too tight tightening damages the part that's being held up.

Lead diameterTightening moment N/mKgfcm Ø 6,35 mm13,7 tot 17,7140 tot 180 Ø 9.52 mm34,3 tot 41,2350 tot 420 Ø 12.7 mm49,0 tot 56,4500 tot 575 Ø 15,88 mm73,5 tot 78,4750 tot 800

Inside shiny without scratches

2. Connection outside unit • Connect the pipe to the connection part of the valve in the same way as with the inner unit. Use the same torque as for the inner unit to attach the screw and tighten it with a snapkey or wrench.
Show 13 more labels / short text on this page
Draw Incomparable Bramen · Blackberries Copper pipe · Hotnut · Larger · Pipe cutter · Copper pipe· Flare tool · Clamp-type Wing nut type · Round smooth · Mal Juk · Mal · Copper line · Wartelmoer copper pipe
Page 13 of the Hisense AMW3 user manual — 5-4 VENTILATION PROCEDURE•LEAKAGE TEST
Page 13 · click to enlarge
Page 13
  • INSULATION AND TAPE
  • Cover the connections of the pipes.
  • Isolate all pipes including the valves on the side of the outer unit.
  • Use pipe tape for taping from the point where pipes enter the outside unit. - Attach the end of the tape with self-adhesive tape. - If the pipes have to run above a ceiling, cabinet or high temperature and humidity room, additional insulation must be provided in order to avoid condensation.

(10) Re-connect the cover cap to the service connection in its original condition. (11) Turn the hood. (12) Leakage test.

LET OP: Each set of pipes shall be separately ventilated.

5-4 VENTILATION PROCEDURE•LEAKAGE TEST

1. De-venturisation procedure (1) Connect the cooling lines (both liquid and gas pipes) between the inside and outside unit. (2) Remove the cover cap from the service connection on the valve in the gas line at the side of the external unit. (The valve does not work in the condition of its release from the factory [completely closed with cover].) (3) Connect the manometer set and vacuum pump to the service connection on the valve in the gas pipe at the side of the external unit. (4) Turn on the vacuum pump. Vacuum for more than 15 minutes. (5) Check the vacuum with the pressure gauge and then close the valve and stop the vacuum pump. (6) Leave it for one to two minutes. Make sure the hand of the pressure gauge remains in the same position. Confirm that the pressure gauge indicates -0,101 MPa or -760 mHg. (7) Remove the pressure gauge set from the service connection of the valve. (8) After all cooling pipes are connected and vacuum sucked, fully open all valves on both sides of the gas line and liquid pipe. (9) No refill is required for a pipe length of up to 15 m. For pipe lengths exceeding 15 m, the required quantity of coolant shall be refilled.

Composite pressure meter (for R410A)

-0,101 MPa (-760 mmHg)

Adapter to counter backflow.

(Or a vacuum pump with a function against backflow)

Show 6 more labels / short text on this page
Pressure gauge (for R410A) · Manometer set (for r410A), · Handle layer · Hanger high · Filling hose · Watch glass
Page 14 of the Hisense AMW3 user manual — Heating circuit
Page 14 · click to enlarge
Page 14

6. FLOW DIAGRAM COOLANT

EXTERNAL UNIT INSIDE UNIT

Diagram . .
Diagram . .

Heating circuit

Page 15 of the Hisense AMW3 user manual — Climate Solutions B. V.  Exclusive Hisense Importer Benelux
Page 15 · click to enlarge
Page 15

PACKAGING LIST

External unit

No. NAME NUMBER

Correct removal of this product.

This indication indicates that this product should not be removed uncontrolled, causing damage to the environment or health. Recycle it in a responsible way and promote the sustainable reuse of materials. Return the used device by using return and collection systems or contact the dealer where the product was purchased. They can recycle this product in an environmentally friendly way.

THE SYMBOL * INDICATES A COMPONENT TO BE PURCHASED SEPARATELY.

HS

Climate Solutions B. V. Exclusive Hisense Importer Benelux

HS Climate Solutions B. V. Carnelian 400 3316 KC Dordrecht

e. [email protected] w. www.hs-cs.nl t. 088-4355450 f. 088-4355451

SK No 60753986 IBAN No EN92ABNA0443804362 VAT NO. EN854044954B01

The design and specifications may be modified without further notice. Images and diagrams are for information purposes only, and may be modified without further notice.

Show 4 more labels / short text on this page
External unit · Drainage curve* · Manual · Version number 20150101-EN
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Hisense AMW3

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Hisense AMW3

Be the first to ask — other owners or our team will answer.

Original document

Hisense AMW3 manual PDF

15 pages·2.2 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…