Thank you for your decision to purchase a GUTMANN range hood!
Please read the following information and explanations on the professional installation of your new hood from GUTMANN carefully before commissioning takes place. Please also note our operating and installation instructions as well as the cleaning recommendations contained therein, so that you have long enjoyment of your device.

Dear customer, · dear client,

1 Precautionary Statements 4 – 5
All information on the hoods corresponds to March 2013. We reserve the right to make technical changes that serve progress.

Assembly, connection, commissioning and repair shall be carried out only by a professional. This specialist can determine the appropriate attachment and exhaust air guidance of the range hood. The attachment shall be suitable for the weight of the range-finder hood and the loading on the substrate. Consider the extract values of the dowels supplied. Depending on the substrate, these have the following values: Dübel Ø10 mm: Concrete B25 9.4 kN Mau- orbed Z20 5.2 KN lime sand solid stone KSV20 4.8 KN. In other unsafe substrates, a person skilled in the art is responsible for building matters, e.g. a structural engineer or architect. Risk of injury! Sharp edges can be located in the hood body due to production. Protective gloves shall be worn during assembly. Electric shock hazard The mains voltage shall be consistent with the information on the nameplate. This is located in the region of the filters inside the hood. Connect the range extractor hood only to a properly installed protective contact socket. The socket shall be easily accessible after assembly in order to disconnect the range extractor hood from the mains voltage as required. In the case of fixed connection (e.g. If no such outlet is provided, the range-extraction hood shall be connected to mains voltage only by a professional electrician. For the fixed connection, the range extractor hood must be connected to a single circuit with separating device. Switches with a contact opening of at least 3 mm and all-pole switches, e.g. LS switches and contactors. Before work on the electrical connection of the range extractor hood, switch off mains circuit(s). Before drilling fastening holes, check that no electrical lines can be damaged by the drill. The electrical connection must be prepared in such a way that the exhaust hood can thus simply be connected. Local regulations must be respected. Air ducting (for air operation) The exhaust air shall not be conducted into a chimney suitable for use in the flue gases of fuel-fuelled appliances (e.g. gas) is used. Administrative requirements for the discharge of exhaust air must be observed. The exhaust air path must be prepared in such a way that the range extractor hood can easily be connected to it. The exhaust hose must be laid without kinks. If the exhaust hood is simultaneously operated with other combustion sites (e.g. wood-fired, gas-firing, oil-fire or coal fired appliances) in a room, lethal combustion gases can be returned to the space by an underpressure that arises. The operator must therefore ensure that sufficient air is supplied at all times. The vacuum in the room shall not exceed 4 Pa (0,04 mbar). In B-version max. not exceeding 5 m channel length.

Fireplace for solid fuels Above a fireplace for solid fuels, from which there is a risk of fire (e.g. The fireplace is not designed to be used for the purpose of ventilation, but rather for use in other applications. Minimum distance from the cooking appliance The requirement for gas is 650mm. In order to prevent condensate formation, a back-pressure flap must be mounted directly on the air outlet outside. Respect the applicable installation requirements and installation instructions of gas appliance manufacturers. The installation of the range-extraction hood over gas cooking stations is permitted at a minimum distance of 650 mm only if the following nominal thermal loads (Hs) are not exceeded: Gas stove Loading of a cooking point max. 3.0 KW loading of all cooking stations max. 8.3 KW loading of the oven max. 3,9 KW Cooking troughs Loading of a cooking point max. 3.9 KW loading of all cooking stations max. 11.3 KW For C recirculated air versions, it can lead to swirl of the air in high stages! Before the hood leaves our factory, it is subjected to a detailed functional test by our quality control before shipment and all functions are tested. The images, drawings and models shown on the operating instructions may differ from the supplied model or You may have options that are not included in the scope. Technical changes reserved!



3 Motor module with tower subconstruction
5 Screw set (Bonch-motor module connection)
8 Connecting piece for exhaust air smoke
10 Ceiling flange with mounting brackets
11 Hifi system (Subwoofer + transformer + holder),
loosely growing when assembled see page 14, point. 7)
13 Loudspeakers (mounted, de-assembled before assembly)



Integrated motor: - Air power: free-blowing 950m3/h - Power: 270 Watt Filters: - 1 piece - Aluminium - Dimensions 290 x 240 mm Lighting: - 2 pieces LED Functional lighting 7.4 Watt
- 1 piece of LED lighting "ambience" 20 watts
Weight: - 65 kg Control element: - 6 - Point control part front right - LED power indicator on the right hood dimensions: - Size: 1050 x 500 mm tower (in one piece): - 312 x 272mm height according to customer specification









Consider the extract values of the dowels supplied. Depending on the substrate, these have values which are as follows: - Dübel Ø 10 mm: - Concrete B25 9.4 KN, - Wall bricks Z20 5.2 CN, - Lime sand solid stone KSV20 4.8 KN. In other unsafe substrates, a specialist in construction matters, e.g. Ask a structural engineer or architect.

Transport, unpacking and setting up If the device is brought into the operating room from a cold environment, dewing may occur. Please wait until the device is temperature-adjusted and absolutely dry before you put it into operation. The acclimatization time depends on the temperature difference and device as well as its structure. It should be at least 12 hours.

Please wear protective gloves during assembly to exclude the risk of injury. Before the assembly of the hood, building-side prerequisites for an installation of the bonnet are created, kitchen appliances covered etc. Prepare suitable exhaust air guidance in the ceiling, open intermediate ceiling, create breakthroughs etc.










Push the mounting flange with motor module over the exhaust hose and suspend it on the stick screws. Then, align the motor module with nuts. For circulating air, see page 18 - 19 !

(partially pre-assembled)





Be mindful of the buckling. Attention: * Then, when the boot is in a position of height (or height) it will be removed.HGH) of more than 750mm to push the tower over the tow subconstruction before mounting the ceiling.












After completion of the assembly work, we recommend cleaning stainless steel surfaces with our special cleaner TZ 710. For cleaning the glass surfaces we recommend Glass Cleaner type. No: 05999704. For aluminum surfaces, use a soft microfiber cloth. Do not use dry cloths. Use a mild window cleaner and no aggressive, acidic or lye-containing cleaners! Do not use scrubbers.


Subwoofer with transformer + holding screw to the subconstruction of the tower, set air circulating kit into the tow. Insert electrical supply line. screwing air set to the threaded connection points, attach hose clamps. Prefabricated assembly as under point 7 - 14 Described to continue!







Disposal Packaging The range extractor hood packaging is recyclable. The packaging materials used are carton and polyethylene film (PE). These materials must be disposed of in an environmentally sound manner and according to the local regulations applicable. Exhaust hood Through an environmentally sound disposal of obsolete household appliances, you are also happy to advise your opinion. Environmental statements All models from GUTMANN are labelled in accordance with the European Directive 2002/96/EC on electrical and electronic equipment (waste electrical and Electronic Equipment – WEEE). This directive sets out the framework for an EU-wide takeback and recycling of old equipment. Please inform yourself about current disposal routes at your specialist dealer. Technical data Connection to the network:
230 V / 50 Hz, max. 270 Watts



















Exclusive hoods GUTMAN GUTMAN GUTMANN Gambia Mühlacker Straße 77 D-75417 MühlACKER Deutschland info@gutmann-exclusive.eu www.gutmann-exclusive.eu HRB 705602 Mannheim District Court DE263391836 Index: 05 / 13 Article No. 2515