EN
Grasslin logo
Official user manual

Grasslin Feeling RF

322 pages·6.2 MB·Thermostat·PDF·ENJA
Grasslin Feeling RF
Table of Contents 27 sections Safety instructions · Product details · A B · Installation and assembly General information · … ShowHide
Page 1 of the Grasslin Feeling RF user manual — Safety instructions
Page 1 · click to enlarge
Page 1

Safety instructions

by a qualified electrician. DANGER

It is imperative to observe the generally applicable safety measures, e.g. before starting any work

on the appliance, switch off power supply and secure against switching on. Interventions in and changes to the device result in the voiding of the warranty claim. Observe your national regulations and the respective safety provisions.

Page 2 of the Grasslin Feeling RF user manual — D
Page 2 · click to enlarge
Page 2

Product details

A B

Proper use feeling/feeling rf are a new generation of chrono- thermostats with new modern design. The large LCD display enables the display of information and control of all integrated functions. The device may only be used in combination with your heating system.

Grasslin Feeling RF — Product details diagram (page 2)
Fig. 1 · Product details

Assembly description A Moveable sliding cover B Keys for manual override function C Window D Keyboard E Battery compartment F Display

D

E

Page 3 of the Grasslin Feeling RF user manual — Product details
Page 3 · click to enlarge
Page 3

Technical data – Relay version Power supply: 2 x 1.5 V AA LR6 alkaline batteries Battery service life: 2 years (depending on switching frequency) Switching output: SPDT (potential-free) Switching capacity: 6(2) A 250V AC Wire cross-section to relay terminals: 0.5 mm2 – 1.5 mm2 Room temperature display resolution: 0.1ºC Temperature setting display: Program: +5ºC…+32ºC (0.5ºC steps) Frost protection: 5ºC (adjustable 3ºC…7ºC) Time setting resolution: Time of day: 1 minute Program: 30 minutes Temperature measurement (heating system): 3 K/hour Programming: weekly program with up to 48 time and temperature programs changes Pre-programmed programs: 4 + 1 user-defined Protection class/type: II/IP40 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 87 x 154 x 27

Page 4 of the Grasslin Feeling RF user manual — Product details
Page 4 · click to enlarge
Page 4

Technical data – RF Set, Transmitter Power supply: 2 x 1.5 V AA LR6 alkaline batteries Battery service life: 2 years (depending on switching frequency) Room temperature display resolution: 0.1ºC Temperature setting display: Program: +5ºC…+32ºC (0.5ºC steps) Frost protection: 5ºC (adjustable 3ºC…7ºC) Time setting resolution: Time of day: 1 minute Program: 30 minutes Temperature measurement (heating system): 3 K/hour Programming: weekly program with up to 48 time and temperature programs changes Pre-programmed programs: 4 + 1 user-defined RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class/type: II/IP40 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 87 x 154 x 27

Page 5 of the Grasslin Feeling RF user manual — Product details
Page 5 · click to enlarge
Page 5

Technical data – RF Set, Receiver Power supply: 230 V +/-10% 50-60 Hz Switching output: SPDT (potential-free) Switching capacity: 5 (1) A 250 V AC Wire section to relay terminals: 0.5 mm2 – 1.5 mm2 RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class/type: II/IP20 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 87 x 108 x 37

Page 6 of the Grasslin Feeling RF user manual — Installation and assembly General information
Page 6 · click to enlarge
Page 6

Installation and assembly General information

1.5 m

Page 7 of the Grasslin Feeling RF user manual — Open housing Wall mounting
Page 7 · click to enlarge
Page 7

Open housing Wall mounting

For wired and wireless version.

Page 8 of the Grasslin Feeling RF user manual — 1 2 3 M
Page 8 · click to enlarge
Page 8

Connection

Wiring diagram

Wiring exampleBoiler/heater

NC

NO

Wiring exampleMotorized valve

N L 230 V~ NC

230 V AC

NO

For wireless connection, please refer to chapter RF commissioning.

1 2 3 M

Show 4 more labels / short text on this page
Boiler/heater · Valve · close · open
Page 9 of the Grasslin Feeling RF user manual — Close housing Insert batteries
Page 9 · click to enlarge
Page 9

Close housing Insert batteries

For wired and wireless version.

Only use 2 x 1.5 V type AA.

click! · click!

Page 10 of the Grasslin Feeling RF user manual — Close housing Insert batteries
Page 10 · click to enlarge
Page 10

Operating and adjustment Operating information Flashing texts signal the need for an entry. If no button is pressed for 2 minutes, the device reverts

to the Automatic mode. All settings need to be confirmed with OK. All settings saved will remain in the memory. The histogram shows the programmed temperature profile 7 – 14°C = displayed as one segment 15 – 24°C = one segment displays 1°C over 24°C = one segment displays 2°C

Page 11 of the Grasslin Feeling RF user manual — J K
Page 11 · click to enlarge
Page 11

Display

A C

B

A Current week day B Battery C RF signal D Current time E Set temperature F Off mode G Histogram over 24 hours H Current temperature I Operating mode J Status indication K Current date

Grasslin Feeling RF — Display diagram (page 11)
Fig. 2 · Display

J K

D

E

H

F

G

Page 12 of the Grasslin Feeling RF user manual — F
Page 12 · click to enlarge
Page 12

Function keys

A +/– buttons used to increase/decrease tem-

peratures. B OK-button to confirm settings and go to the

A

next step. C MODE-button to select from the available

B

operating modes. D ESC-button used for ON/OFF, go one step back

D

E

in menu or return to main menu by pressing the button more than 3 seconds. E SET-button for settings following

F

G

commissioning. F +/– buttons used to increase/decrease hours,

days and events. G RESET-button to return to factory settings. The

programs are retained in the case of a reset. The date and time must be set again. Press reset button with a blunt object (pen).

Page 13 of the Grasslin Feeling RF user manual — B
Page 13 · click to enlarge
Page 13

Configuration General information For the use of this manual you must observe the following informations:

Buttons which can be pressed during an

action are shown in black. The related display is also shown in black. Follow exactly the numbers of the sequence

of operation. The configuration of the device is described

A

Grasslin Feeling RF — A diagram (page 13)
Fig. 3

based on configuration. After starting the device for the first time,

B

D

follow the menu for a correct configuration of the device. Following commissioning, you can also

change the configuration by pressing the SET-button.

A Sequence of operation B Pressed buttons are shown in black. C Flashing elements are shown in black D Fixed elements are shown in grey

Page 14 of the Grasslin Feeling RF user manual — Function keys
Page 14 · click to enlarge
Page 14

Initial start-up Set date and time Sequence for setting the date and time during initial start-up. 15/6/2008 appears as factory default.

To set the date and time after initial start-up press the SET-button, then choose Date or Time Menu with the upper +/– buttons and confirm with OK.

Grasslin Feeling RF — Function keys diagram (page 14)
Fig. 4 · Function keys
Page 15 of the Grasslin Feeling RF user manual — Function keys
Page 15 · click to enlarge
Page 15
Grasslin Feeling RF — Function keys diagram (page 15)
Fig. 5 · Function keys

The time is set in the same way as the date.

Page 16 of the Grasslin Feeling RF user manual — Programming Sequence for specifying programs during initial start-up
Page 16 · click to enlarge
Page 16

Programming Sequence for specifying programs during initial start-up

To specify programs after initial start-up press the SET-button, then choose the Prog menu with the upper +/– buttons and confirm with OK.

Grasslin Feeling RF — Programming Sequence for specifying programs during initial start-up diagram (page 16)
Fig. 6 · Programming Sequence for specifying programs during…
Page 17 of the Grasslin Feeling RF user manual — Programming Sequence for specifying programs during initial start-up
Page 17 · click to enlarge
Page 17
Grasslin Feeling RF — Programming Sequence for specifying programs during initial start-up diagram (page 17)
Fig. 7 · Programming Sequence for specifying programs during…

Mo Tu We Th Fr Sa Su Choose between:

7 days – one programm

5-2 days – one program per day block

1-7 days – each day an individual program

free block formation – one program per day block

Grasslin Feeling RF — Programming Sequence for specifying programs during initial start-up diagram (page 17)
Fig. 8 · Programming Sequence for specifying programs during…
Page 18 of the Grasslin Feeling RF user manual — P1
Page 18 · click to enlarge
Page 18

Select program Each weekday or day block must be allocated a program P1, P2, P3, P4 (pre-defined) or Pd (user- defined).

P1

P2

15°C 20°C 17°C 21°C

15°C 20°C 17°C 21°C

15°C

15°C

P3

P4

15°C 20°C 17°C 21°C

15°C 20°C 18°C

15°C 20°C 17°C 21°C

15°C

Pd User-defined program. During initial start-up, program will be shown with 15ºC from 00:00 to 23:59 PM.

Page 19 of the Grasslin Feeling RF user manual — P1
Page 19 · click to enlarge
Page 19

If you wish you can modify the pre-defined programs. Use the upper +/– buttons to increase/decrease the temperature of each segment by 0.5°C. Use the lower +/– buttons to go forward/backward 30 minutes each time and copy the selected temperature value.

Grasslin Feeling RF — P1 diagram (page 19)
Fig. 9
Page 20 of the Grasslin Feeling RF user manual — P1
Page 20 · click to enlarge
Page 20

Settings After commissioning you can change the date, time, temperature and time programming. By pressing the upper +/– buttons you jump to the different menus. 1-3 = adjustment of date 2-3 = adjustment of time 3-3 = adjustment of time and temperature programming

Grasslin Feeling RF — P1 diagram (page 20)
Fig. 10
Page 21 of the Grasslin Feeling RF user manual — P1
Page 21 · click to enlarge
Page 21
Grasslin Feeling RF — P1 diagram (page 21)
Fig. 11

You are now able to adjust the date as described in the initial start-up. The sequence of setting the time is similar to the method for settingthe date.

With the lower +/– buttons you can choose days or day blocks for programming and confirm with OK. Go to operation number . By pressing the OK-button you can choose between the pre-defined programs P1 – P4 or the user-defined program Pd. Go to operation number .

Page 22 of the Grasslin Feeling RF user manual — P1
Page 22 · click to enlarge
Page 22
Grasslin Feeling RF — P1 diagram (page 22)
Fig. 12
Page 23 of the Grasslin Feeling RF user manual — P1
Page 23 · click to enlarge
Page 23
Grasslin Feeling RF — P1 diagram (page 23)
Fig. 13

By pressing the lower +/– buttons you can go through the program to check it. For editing the program, use the upper +/– but- tons to increase/decrease temperature in each segment by 0.5°C. Use the lower +/– buttons to go forward/backward and copy the selected temperature value.

Page 24 of the Grasslin Feeling RF user manual — P1
Page 24 · click to enlarge
Page 24

Operating modes Set operating modes Follow the sequence for selecting the desired operating mode. The operating modes in the device appear in the same order as described here.

Press and hold the ESC-button for 3 seconds to return to Auto mode.

Example:

Grasslin Feeling RF — P1 diagram (page 24)
Fig. 14
Page 25 of the Grasslin Feeling RF user manual — P1
Page 25 · click to enlarge
Page 25

Auto Symbol: After each programming session, the device automatically returns to the Auto mode. The predefined or user-defined program run here.

Grasslin Feeling RF — P1 diagram (page 25)
Fig. 15
Page 26 of the Grasslin Feeling RF user manual — P1
Page 26 · click to enlarge
Page 26

Manual-ECO-Fix Symbol: Manual-ECO-Fix mode calculates an average temperature of the actual program. This temperature is is kept for the whole day until any user‘s intervention is made. To return to Auto mode, press OK. The average temperature is the starting point for increasing or decreasing the desired temperature, pressing upper +/– buttons. The new temperature set value is then, after 3 sec., set for all day long. Example: 4 different temperatures in the actual program (e.g. 17°C, 19°C, 20°C and 22°C). Average temperature is then 19,5°C.

Grasslin Feeling RF — P1 diagram (page 26)
Fig. 16
Page 27 of the Grasslin Feeling RF user manual — P1
Page 27 · click to enlarge
Page 27

Cleaning mode Symbol: This mode sets the device into OFF mode for a preset time of 2 hours. During the cleaning time, remaining time is shown until running mode elapsed. After the Cleaning mode is elapsed, the device returns into Auto mode.

To end Cleaning mode early, press ESC-button for more than 3 seconds. The anti-freeze protection is granted.

Grasslin Feeling RF — P1 diagram (page 27)
Fig. 17
Page 28 of the Grasslin Feeling RF user manual — P1
Page 28 · click to enlarge
Page 28

Countdown mode Symbol: This function runs into a desired set temperature during certain period of time. Adjustable period of time is 1 – 23 hours. After the time is elapsed, the device returns into OFF mode (Anti-freeze tempera- ture is kept). During the Countdown mode, remaining countdown time is indicated. Example: The device shall be run into OFF mode after 4 hours.

To end Countdown mode early, press ESC-button for more than 3 seconds.

Grasslin Feeling RF — P1 diagram (page 28)
Fig. 18
Page 29 of the Grasslin Feeling RF user manual — P1
Page 29 · click to enlarge
Page 29

Party mode Symbol: This mode allows the user to set a desired temperature during defined period of time. Adjustable period of time is 1 – 23 hours. After the time is elapsed, the device returns into the mode before the Party mode was activated. During the Party mode, the rest of the time is indicated. Example: The temperature shall be set for 6 hours on 24°C.

To end Party mode early, press ESC-button for more than 3 seconds.

Grasslin Feeling RF — P1 diagram (page 29)
Fig. 19
Page 30 of the Grasslin Feeling RF user manual — P1
Page 30 · click to enlarge
Page 30

Holiday mode Symbol: This function runs into a desired set temperature during certain period of time. Adjustable period of time is 1 – 90 days. After the time is elapsed, the device returns into the mode before the Holiday mode was activated. During the Holiday mode, the rest of the days is indicated. Example: The temperature shall be set for 16 days on 13°C.

To end Holiday mode early, press ESC-button for more than 3 seconds.

Grasslin Feeling RF — P1 diagram (page 30)
Fig. 20
Page 31 of the Grasslin Feeling RF user manual — P1
Page 31 · click to enlarge
Page 31

Operating status Manual override Symbol: While the sliding cover is closed, you can temporarily adjust the temperature in the current period with the upper +/– buttons. It is not necessary to confirm the setting with OK. The setting will remain as temperature set value until the next programmed change (time and temperature) appears. To return into Auto mode, press and hold upper +/– buttons for 3 seconds, or open the sliding cover and press OK-button.

Grasslin Feeling RF — P1 diagram (page 31)
Fig. 21
Page 32 of the Grasslin Feeling RF user manual — P1
Page 32 · click to enlarge
Page 32

OFF mode Symbol: This mode switch off the device completely. To activate this mode press and hold ON/OFF/ESC-button for more than 5 seconds. To leave this mode press and hold the ON/OFF/ESC-button again for more than 5 seconds.

The anti-freeze protection is granted.

Grasslin Feeling RF — P1 diagram (page 32)
Fig. 22
Page 33 of the Grasslin Feeling RF user manual — P1
Page 33 · click to enlarge
Page 33

Low battery Symbol: A low battery level is indicated with the battery icon in the display. Please change the batteries. If batteries are not placed or are installed in the wrong polarity, text will appears on display until they are placed or installed in the right polarity.

If the battery goes completely empty, the programming is protected.

Grasslin Feeling RF — P1 diagram (page 33)
Fig. 23
Page 34 of the Grasslin Feeling RF user manual — P1
Page 34 · click to enlarge
Page 34

User menu/Configuration Symbol: Press the MODE-button and SET-button at the same time until User menu is shown in the display. To go to previous menu press ESC-button. It is possible to adjust: RF commissioning (RFC): Enable/disable continuous radio signal Offset (OFS): Possibility to adjust/modify the measured temperature (-5°C...+5°C) Summer/Winter time (SWT): enable/disable automatic summer/winter time change Time Format (TMF): possibility to change time format into 24 hours or 12 hours (default: 24 hours) Restore Default (DFL): Restore values to factory default status.

Use lower +/– buttons to navigate through menus. Use upper +/– buttons to change values and OK to confirm.

Page 35 of the Grasslin Feeling RF user manual — P1
Page 35 · click to enlarge
Page 35

Installation menu Symbol: To access this Configuration menu, press the MODE-button, the OK-button and SET-button at the same time until Installer menu is shown in the display. Press ESC-button to go to previous Menu.

The ajustments in this menu are only for experts. All possibilities for adjustment are shown with a self-explaining, floating real text in the display. Use lower +/– buttons to navigate through menus. Use upper +/– buttons to change values and OK to confirm.

Page 36 of the Grasslin Feeling RF user manual — P1
Page 36 · click to enlarge
Page 36

Following adjustments are possible: High Temp (HIT): set maximum temperature value for programming from low temperature value up to +32°C (default: +32°C) Low Temp (LOT): set minimum temperature value for programming from +7°C up to high temperature value (default: +15°C) Frost protection (FRT): set anti freeze minimum temperature value from +3°C to +7°C (default: 5°C) Regulation (REG): possibility to select between PID or 2 points regulation (default: PID) Differential (DIF): possibility to modify differential value from 0,1 K to 0,9 K (default: 0,4 K) Keypad Lock (LOK): enable keypad to protect against non authorized interventions To enable/disable the keypad lock press and hold MODE- and ESC-button for more than 3 seconds. Operating hours (OPT): this feature shows total operating running time (max. 99.999 hours) Battery Level (BAT): battery charge level is shown on display

Page 37 of the Grasslin Feeling RF user manual — RF commissioning Installation of the receiver
Page 37 · click to enlarge
Page 37

RF commissioning Installation of the receiver

230 V ~

50 Hz

Page 38 of the Grasslin Feeling RF user manual — RF commissioning Installation of the receiver
Page 38 · click to enlarge
Page 38

Installation of the radio link The transmitter and receiver are pre-commissioned. If the radio link doesn‘t work correct, follow the sequence of commissioning. Press and hold the black button of the receiver until the LED light has flashed twice. Release the button and the LED light will remain illuminated. Press and hold MODE-button and SET-button of the transmitter at the same time for more than 3 seconds to enter into the User menu. Then press the OK-button until RF Comm is displayed.

LED 2x

Page 39 of the Grasslin Feeling RF user manual — RF commissioning Installation of the receiver
Page 39 · click to enlarge
Page 39

Press upper + button (– button disables the RF signal) to enable an continous RF signal. The receiver LED will go out as soon as a signal from the transmitter is received. Then press the OK-button, the radio link between transmitter and receiver is now established. Press the ESC-button to return to Auto mode.

Receiver: When operating in heating mode and an ON signal is received, the LED illuminates conti- nously. When an OFF signal is received the LED will flash intermittently.

Grasslin Feeling RF — RF commissioning Installation of the receiver diagram (page 39)
Fig. 24 · RF commissioning Installation of the receiver
Page 40 of the Grasslin Feeling RF user manual — RF commissioning Installation of the receiver
Page 40 · click to enlarge
Page 40
Page 40 of the Grasslin Feeling RF user manual — RF commissioning Installation of the receiver

Ask about the Grasslin Feeling RF

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Grasslin Feeling RF

Be the first to ask — other owners or our team will answer.

Original document

Grasslin Feeling RF manual PDF

322 pages·6.2 MB·Thermostat·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…