Table of Contents 80 sections M40 DATALOGGER User Manual · 1 M40 KIT · 2 GPS WORKING PRINCIPLE · 3 SUGGESTIONS AND PRECAUTIONS DURING INSTALLATION · … ShowHide
M40 DATALOGGER User Manualp.11 M40 KITp.62 GPS WORKING PRINCIPLEp.73 SUGGESTIONS AND PRECAUTIONS DURING INSTALLATIONp.7M40 PCp.84 M40: CONTROLS AND INDICATORSp.95 M40 WIRING LOOMSp.10ECUp.10DATALOGGERp.106 FIRMWARE, CONFIGURATION, SETUP FOR M40 DATALOGGERp.117 USING M40 DATALOGGERp.128 USING M40 WITH A PCp.14SELECTED TRACKp.18“OK” BUTTONp.18“CREAT NEW TRACK”p.18BUTTONp.18ICONp.19TRACK ZOOM BUTTONSp.21FINISH LINE (FL)p.219 M40 TECHNICAL CHARACTERISTICSp.441 ANALOGUE CHANNELSp.462 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS)p.65BEACOp.70BEACONp.70SW1p.713 CAN CHANNELSp.724 INPUT CAPTURE CHANNELS (IC CHANNELS)p.775 “WATCH” functionp.82“WATCH” ICONp.831 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS)p.892 “EXP” CONNECTOR (M40 STD. - EXP. - PLUS)p.903 “EXP1” CONNECTOR (ONLY M40 EXP. - PLUS)p.904 “EXP2” CONNECTOR (ONLY M40 PLUS)p.911 MULTILINK WIRING code GL-0018-AAp.92BATTERY LESS SWITCHp.92DATALOGGER M40p.92CONNECTORp.922 EXPANSION WIRING code GL-0041-AAp.93ANALOGUE INPUT AD1p.93EXP CONNECTORp.93ANALOGUE INPUT AD2p.93ANALOGUE INPUT AD3p.93FREQUENCY INPUT IC1p.93FREQUENCY INPUT IC2p.93AD1; AD2;p.93AD3p.93IC1; IC2p.933 EXPANSIONE WIRING code GL-0042-AAp.94ANALOGUE INPUT AD4p.94EXP1 CONNECTORp.94ANALOGUE INPUT AD5p.94ANALOGUE INPUT AD6p.94FREQUENCY INPUT IC3p.94SW1 INPUTp.94AD4; AD5;p.94AD6p.94IC3; SW1p.944 EXPANSION WIRING code GL-0043-AAp.95ANALOGUE INPUT AD7p.95EXP2 CONNECTORp.95ANALOGUE INPUT AD8p.95ANALOGUE INPUT AD9p.95FREQUENCY INPUT IC4p.95FREQUENCY INPUT IC5p.95AD7; AD8;p.95AD9p.95IC4; IC5p.955 DATA DOWNLOAD WIRING code GL-0019-AAp.96M40 USB CONNECTOR PC USB PORTp.966 POWER WIRING code GL-0036-AAp.97MAIN M40 CONNECTORp.97GP1 EVO CONNECTORp.97POWER SUPPLY (POSITIVE)p.97POWER SUPPLY (NEGATIVE)p.97AUXILIARYp.97POWERp.97WARNING: AVOID SHORTCIRCUITS USING AUXILIARY POWER SUPPLYp.977 POWER WIRING code GL-0037-AAp.98BATTERY CONNECTOR CODE DA00010000p.98ALIMENTAZIONEp.98
Page 1 of the Get M40 user manual — M40 DATALOGGER User Manual
Page 1 · click to enlarge
Page 1
Get M40 — M40 DATALOGGER User Manual diagram (page 1)
Fig. 1 · M40 DATALOGGER User Manual

M40 DATALOGGER User Manual

Page 2 of the Get M40 user manual — M40 DATALOGGER User Manual
Page 2 · click to enlarge
Page 2

Release FW 1.42

2014 - GET by Athena Evolution. All right reserved. The content of this document, part of this document, could be copied, transferred, send or memorized on

other form without the written consent of GET by Athena Evolution .

GET has the right to change without notice the content of this manual.

Page 3 of the Get M40 user manual — M40 DATALOGGER User Manual
Page 3 · click to enlarge
Page 3

INDEX 1 M40 KIT 6 2 GPS WORKING PRINCIPLE 7 3 SUGGESTIONS AND PRECAUTIONS DURING INSTALLATION 7 3.1 Precautions for M40 installation 7 3.2 GPS antenna installation 7 3.3 M40 system installation 8 4 M40: CONTROLS AND INDICATORS 9 4.1 Diagnosis LEDs 9 5 M40 WIRING LOOMS 10 6 FIRMWARE, CONFIGURATION, SETUP FOR M40 DATALOGGER 11 7 USING M40 DATALOGGER 12 7.1 Importance of data logging 12 7.2 Getting started 12 7.2.1 GPS fixing 12 7.3 Data logging 12 7.4 Internal accelerometers 13 8 USING M40 WITH A PC 14 8.1 Connection to a pc 14 8.2 Download of recorded sessions 14 8.3 Visualizing recorded sessions 17 8.4 Set the default track in the device 19 8.5 Track creation from a recorded session 20 8.6 Instrument setup download and updating 22 8.6.1 Instrument setup download and updating with DATA MANAGER software 22 8.6.2 Instrument setup download and updating with GATE software 23 8.7 Starting and stopping logging (MANUAL) 25 8.7.1 Starting and stopping logging (MANUAL) with DATA MANAGER 25 8.7.2 Starting and stopping logging (MANUAL) with GATE 26 8.8 Time syncronization (from pc) 28 8.8.1 Time syncronization with DATA MANAGER 28 8.8.2 Time syncronization with GATE 28 8.9 M40 configuration 30 8.9.1 M40 configuration with DATA MANAGER 31 8.9.2 M40 configuration with GATE 32 8.9.3 Data logging parameters modification 34 8.9.4 Change of system time 36 8.9.5 Lap trigger modification 36 8.9.6 GRSY channel setting 36 8.9.7 Serial protocol setting 37 8.9.8 CAN parameters setting 37 8.10 M40 setup properties modification 38 8.10.1 M40 setup properties modification with DATA MANAGER 38 8.10.2 M40 setup properties modification with GATE 40 8.10.3 GPS parameters setting 42 8.10.4 Comment, driver and vehicle setting 42 8.11 Firmware update 43 9 M40 TECHNICAL CHARACTERISTICS 44 APPENDIX 1: M40 SETUP 45 1 ANALOGUE CHANNELS 46 1.1 Linear calibration example 46 1.1.1 Linear calibration by using DATA MANAGER 46 1.1.2 Linear calibration by using GATE 49 1.2 GEAR on analogue input calibration 52 1.2.1 GEAR on analogue input calibration by using GATE 52 1.2.2 GEAR on analogue input calibration by using GATE 55 1.3 TPS setup (available only for GATE software) 59 1.4 Suspension potentiometer setting (available only for GATE software) 62 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS) 65 2.1 Adding a SWITCH MAP-SWITCH BUTTON channel 65 2.2 Adding a BEACON channel 69 3 CAN CHANNELS 72

Page 4 of the Get M40 user manual — M40 DATALOGGER User Manual
Page 4 · click to enlarge
Page 4

3.1 Adding a CAN channel 72 4 INPUT CAPTURE CHANNELS (IC CHANNELS) 77 4.1 IC channel calibration (connected to a wheel speed sensor) 77 4.2 IC channel calibration (connected to a RPM sensor) 81 5 “WATCH” function 82 5.1 Start and stop “WATCH”: real time channel visualization 82 5.2 “WATCH” channel calibration 86 5.3 Setting channel zero in “WATCH” 87 5.4 Setting channel offset in “WATCH” 88 APPENDIX 2: CONNECTORS M40 STD. – EXP. - PLUS 89 1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS) 89 2 “EXP” CONNECTOR (M40 STD. - EXP. - PLUS) 90 3 “EXP1” CONNECTOR (ONLY M40 EXP. - PLUS) 90 4 “EXP2” CONNECTOR (ONLY M40 PLUS) 91 5 “USB” CONNECTOR (M40 STD. - EXP.- PLUS) 91 APPENDIX 3: WIRING LOOMS FOR M40 CONNECTION 92 1 MULTILINK WIRING code GL-0018-AA 92 2 EXPANSION WIRING code GL-0041-AA 93 3 EXPANSIONE WIRING code GL-0042-AA 94 4 EXPANSION WIRING code GL-0043-AA 95 5 DATA DOWNLOAD WIRING code GL-0019-AA 96 6 POWER WIRING code GL-0036-AA 97 7 POWER WIRING code GL-0037-AA 98 8 POWER – DATA WIRING code GL-0038-AA 99 9 POWER – DATA WIRING code GL-0039-AA 100 APPENDIX 4: M40 CONNECTION DIAGRAMS 101 1 GP1 EVO - M40 (BATTERY LESS CONFIGURATION) 101 2 GP1 EVO - LC1 EVO - M40 102 3 LC1 EVO - M40 (ANALOG CONNECTION) 103 4 LC1 EVO - M40 (CAN BUS CONNECTION) 104 5 M40 - ANALOG SENSORS SUPPLIED AT 5VDC 105 6 M40 - ANALOG SENSORS SUPPLIED AT 12VDC 106 7 M40 - FREQUENCY SENSORS SUPPLIED AT 12VDC 107

Page 5 of the Get M40 user manual — M40 DATALOGGER User Manual
Page 5 · click to enlarge
Page 5

Dear customer, thank you for choosing a GET DATA ACQUISITION AND ANALYSIS SYSTEMS by Athena Evolution. We are sure that our passion and experience will help you to express successfully in all competitions, we ask you to read carefully this user manual. We are confident that this will help you in the use of you new product GET by Athena Evolution. M40 STANDARD – M40 EXPANSION – M40 PLUS, due to GPS technology, can log not only signal from connected sensors but also data concerning trajectories and vehicle speed. Acquisition and configuration of M40 datalogger (with firmware release less than 1.30) are done via GATE software, MX2 (analysis), Download Manager (device synchronization) and Setup Manager (Setup management).The firmware release over than 1.30 are manage by DATA MANAGER software. This manual is dedicated to illustrate to the end user information on M40 datalogger functions. Otherwise specified, functions described are in Standard (M40 STD.) Expansion (M40 EXP.) and PLUS (M40 PLUS). Different versions of M40 are the followings:

Characteristic/functionMODEL M40 STDM40 EXPM40 PLUS Integrated tri-axle accelerometer Analogue input (0-5V)369 Frequency input (open collector 0-5V, freq. 0 - 20kHz)235 External beacon input- CAN connection2.0 High Speed (bitrate 125 kb/s, 250 kb/s, 500 kb/s, 1Mb/s; Intel and Motorola protocol) Maximum CAN channels128 CAN channel transmission CAN channel reception Logging rate (Hz) in each channel1 – 10 – 20 – 50 – 100 – 500 Auxiliary power output 5 VDC @ 1A Auxiliary power output VBB Logging trigger channelUser selectable (speed, RPM, manual, etc) Switch on delayUser selectable (via software) Data recording switch on delayUser selectable (via software) GPS logging frequency (Hz)5 – oversampled to 10 Average precision GPS module (m)2.5 GPS antennaActive 5V, gain 28dB, SMA connector Start/stop data logging signalling led GPS status signalling led Integrated Real Time Clock (RTC)Yes, with backup battery Internal clock updatingManual (via PC) or automatic (from GPS) Time zone settingVia PC Internal memory (GB)Up to 16 USB communication port Firmware updatefw user updatable via PC Interface softwareDATA MANAGER (GATE for rel. fw <1.30) Case materialAnodized aluminium Protection gradeIP68 Dimension length x width x height (mm)92 x 66 x 20 Weight (g)250260270
Page 6 of the Get M40 user manual — 1 M40 KIT
Page 6 · click to enlarge
Page 6

1 M40 KIT

  • M40 kit is comprehensive of:
  • box
  • M40 datalogger
  • 1 GPS antenna
  • 1 power cable, code GL-0038-AA
  • 1 expansion cables JST-Binder for the connection of external sensors ( only M40 EXPANSION )
  • 2 expansion cables JST-Binder for the connection of external sensors ( only M40 PLUS )
  • 1 USB-JST cable for pc connection
  • 1 CD with software and manuals electronic copy NOTE: kit content can be different accordingly to the versions.
Get M40 — 1 M40 KIT diagram (page 6)
Fig. 2
Page 7 of the Get M40 user manual — 3 SUGGESTIONS AND PRECAUTIONS DURING INSTALLATION
Page 7 · click to enlarge
Page 7

2 GPS WORKING PRINCIPLE

GPS (Global Positioning System) system, on which your GET system is based, uses a spherical positioning algorithm in order to identify the position of receiver the signal coming from satellites. Measuring the time needed by a radio signal to cover the distance satellite-receiver and knowing the precise position of at least 4 satellites, it is possible to identify the 3D position of the receiver. 24 GPS satellites, arranged in orbits inclined at 55 degrees to the equator, are between 18000 and 20000 km from the Earth and they rotate completely in 12 hours. Satellites transmit signals of 1.2 and 1.5 GHz (to avoid errors coming from atmosphere refraction) originated by a single oscillator (atomic clock). Transmitted data contain information on satellite’s orbit and time signal (messages of Ephemeris) that permit to the receiver to define position on earth surface.

Time lapping is done via GPS: this solution avoid uncomfortable beacons side the track and help to have timing references during data analysis. GPS is a stochastic algorithm and it is strictly linked to the correct signal receiving. In case of electromagnetic or ambient interferences the quality of data is not guaranteed. The minimum received number of satellites in order to guarantee a proper quality in time lapping is 5.

3 SUGGESTIONS AND PRECAUTIONS DURING INSTALLATION

We recommend to read carefully following chapters in order to get the best during the installation of M40 in your vehicle.

  • 3.1 Precautions for M40 installation Before proceeding with installation of M40 onto a vehicle please observe the following rules:
  • Work in a user friendly environment (example: enough working space)
  • Disconnect battery wirings
  • Put all removed vehicle parts in a safe place avoiding to damage them
  • Installation in vehicle with internal combustion engine has to be done with the engine cold: during the installation you could be in contact with engine or chassis parts
  • During the job be really careful to connectors and wirings
  • Keep washers, bolts and nuts in a safe place during M40 installation
  • During installation avoid that any part installed interfere with driving parts or with the driver 3.2 GPS antenna installation In order to install properly the GPS antenna please refer to the following instructions:
  • be really careful during GPS antenna movement: Avoid shocks and verify that connector and cable are in a perfect shape
Page 8 of the Get M40 user manual — M40 PC
Page 8 · click to enlarge
Page 8
  • fix the antenna outside the vehicle: obstacles near to the antenna could cause a reduction to the receiving capabilities of the sensor. A wrong position could cause an incorrect lap timing, wrong data acquisition and wrong trajectories
  • do not twist the antenna cable around other cables (especially around high voltage plugs wiring): this could cause inductive interferences and cause problems during the functioning
  • let pass the antenna cable as far as possible from spark plugs and other electromagnetic field. In motorbikes it is preferable to run the cable out of the chassis but in any case in a protected zone
  • fix the GPS connector to the ANTENNA input in MD40 without use excessive torque: do not use tools Some suggestions to fix the antenna: Speed bikes : fix the antenna in the far back part of the motorbike away from heat sources (exhaust) or in

cockpit area (on top of it). Off-road bike: fix the antenna on handlebar handle pad. Car: fix the antenna on top of the roof. Kart: fix the antenna on the higher part of front number plate, if needed manufacture a support to address

the sensor in the proper direction. 3.3 M40 system installation M40 data loggers are done in order to be fixed easily inside all vehicles. For electrical connections please read Appendix 2 and Appendix 3 of this manual. With dedicated cables it is possible to connect directly to ECU by Athena Evolution (example GP1EVO) via CAN bus. The following figure shows in principles a typical installation of a M40 into a motorbike.

M40 PC

Get M40 — M40 PC diagram (page 8)
Fig. 3
Get M40 — M40 PC diagram (page 8)
Fig. 4
Get M40 — M40 PC diagram (page 8)
Fig. 5
Get M40 — M40 PC diagram (page 8)
Fig. 6

GPS antenna · Sensor

Page 9 of the Get M40 user manual — 4 M40: CONTROLS AND INDICATORS
Page 9 · click to enlarge
Page 9

4 M40: CONTROLS AND INDICATORS

1. M40 DEVICE 2: MAIN connection cable 3: EXP connection cable 4: USB connection cable 5: red diagnosis led 6: green diagnosis led 7: GPS antenna connector 8: EXP1 connection cable (only for M40 EXPANSION and M40 PLUS) 9: EXP2 connection cable (only for M40 PLUS) 4.1 Diagnosis LEDs M40 data logger has got two LEDs. The following table shows their meaning:
Get M40 — 4 M40: CONTROLS AND INDICATORS diagram (page 9)
Fig. 7
Cond.LedStatusMeaning 1GreenOffThe device is off 2GreenOn fixThe device is on 3GreenBlinking (frequency 1Hz)Acquiring data 4GreenBlinking (frequency 2Hz)The memory is full 5RedOn fixNot adequate satellites reading 6RedOffAdequate satellites reading 7Green + RedBlinking (frequency 1Hz)The device is connected to PC
Get M40 — 4 M40: CONTROLS AND INDICATORS diagram (page 9)
Fig. 8
Page 10 of the Get M40 user manual — ECU
Page 10 · click to enlarge
Page 10

5 M40 WIRING LOOMS

M40 dataloggers could be linked to the vehicle (or sensors) with specific cables. With “multilink” cable it is possible, for example, connect M40 directly to ECU GP1 EVO (see following picture): In this situation it is possible to give power to m40 directly from ECU and to log all CAN channels coming from ECU. All data like rpm, throttle position, injection time, advance time, etc will be available through only one cable. Interconnection cables are available for EXP, EXP1, EXP2 connectors to connect M40 to analogue sensors or frequency sensors with 3 wirings Binder connector. If you need further information on M40 wirings please refer to Appendix 3,

Get M40 — 5 M40 WIRING LOOMS diagram (page 10)
Fig. 9

ECU

DATALOGGER

Get M40 — ECU diagram (page 10)
Fig. 10
Get M40 — ECU diagram (page 10)
Fig. 11
Page 11 of the Get M40 user manual — 6 FIRMWARE, CONFIGURATION, SETUP FOR M40 DATALOGGER
Page 11 · click to enlarge
Page 11

6 FIRMWARE, CONFIGURATION, SETUP FOR M40 DATALOGGER

  • M40 is based on three internal software:
  • Firmware: this is necessary to guarantee the instrument functioning,
  • Configuration: this is necessary for base setup of the instrument like serial number and identify number.
  • Setup: this is needed by M40 in order to get all information about sensors, calibrations, logging frequencies, etc. You can adjust M40 setup with CONFIG DATALOGGER software (if you are using DATA MANAGER software) or Setup Manager (it’d included into the software suite GATE). Some channels cannot be modified by the user in order to avoid malfunctioning
Page 12 of the Get M40 user manual — 7 USING M40 DATALOGGER
Page 12 · click to enlarge
Page 12

7 USING M40 DATALOGGER

  • Following chapters are written to explain simple rules for the use of the instrument and information given by LEDs. 7.1 Importance of data logging Logging data during test sessions or test bench is becoming more and more important because:
  • You can reduce setup time on the vehicle
  • You can solve driving mistakes
  • You can evaluate vehicle behaviour statically and dynamically
  • You can visualize all logged parameters
  • You can check continuously engine and chassis performances
  • You can see lap times once downloaded 7.2 Getting started Please read carefully following chapters for an optimal use of M40 . 7.2.1 GPS fixing You need to “fix” satellites in order to get trajectories and lap times with MX2 software. The minimum number of satellites to get a correct acquisition is 5. In fixed application (test bench) you do not need GPS. NOTE: M40 continue to search satellites during logging. This permit to start the acquisition also without GPS data. In this case it will be probable that trajectories visualization (done via software) could be compromise. The evidence of this phenomena are fast variations on the position of vehicle (spike), up to some kilometres!!!! 7.3 Data logging Start and stop of data logging could take place with the following modes:
  • Manual: starting the acquisition via software
  • Automatic: - from vehicle speed (Speed) both with GPS or with wheel speed (only with installed sensor) - From engine speed (RPM) - defining a special threshold value from any given input/channel of M40 In standard configuration start/stop are MANUAL . In this condition it is necessary to connect a pc with DATA MANAGER in order to record data . For further information on data logging start/stop see chapter 8.7 and 8.9.3 . To modify logging start/stop mode use Config Datalogger .
Page 13 of the Get M40 user manual — 7 USING M40 DATALOGGER
Page 13 · click to enlarge
Page 13
  • 7.4 Internal accelerometers M40 has got three accelerometers as described in the picture: Values are logged automatically by M40 and therefore can be used with MX2 . Internal accelerometers are System Channels , in M40 setup . Logical names are:
  • ACCX
  • ACCY
  • ACCZ You can see these names in Setup Manager and in Channel Bar of MX2 . You can zero of these sensors with WATCH function in Setup Manager (read Appendix 1 – cap. 5 of this manual).
Get M40 — 7 USING M40 DATALOGGER diagram (page 13)
Fig. 12

+ · + · +

Page 14 of the Get M40 user manual — 8 USING M40 WITH A PC
Page 14 · click to enlarge
Page 14

8 USING M40 WITH A PC

  • Management of M40 is done with a computer with DATA MANAGER software installed. With the pc you can configure and calibrate channels (using Config Datalogger ) and download data (using Download Data ). For further information on software read DATA MANAGER user manual (supplied in electronic format and downloadable in <a href="http://www.getdata.it" rel="nofollow noopener" target="_blank">http://www.getdata.it</a> ). This manual describes also the operative instructions for GATE software (if the procedures are different) 8.1 Connection to a pc In order to connect with a pc following the instructions below:
  • Use a pc with an installed GATE software
  • Connect the download cable to M40
  • Plug the USB into the PC
  • Start the DATA MANAGER software to manage the download, visualize logged data and manage the instrument setup. 8.2 Download of recorded sessions You need to download data before analyzing Follow instructions below:
  • Switch on the M40 (greed led on fix) and connect to the PC (both LEDs will blink together).
  • Verify that all instruction in 8.1 are accomplished.
  • Wait that Windows detect the instrument (the message will be likely in the right low part of the monitor, nearby the clock).
  • Open Download Data and wait that instrument will be present in Devices and Sessions : select the device with a click
Get M40 — 8 USING M40 WITH A PC diagram (page 14)
Fig. 13
Get M40 — 8 USING M40 WITH A PC diagram (page 14)
Fig. 14

Test

Page 15 of the Get M40 user manual — 8 USING M40 WITH A PC
Page 15 · click to enlarge
Page 15
  • If needed, you can stop acquisition pressing Stop Acquis in the right part of Download Data page.
  • Click on to the cross at the left of the name in order to see stored sessions’ list.
  • Select the needed session with left click(blue background).
  • Click on Download File and wait until the end of operation.
  • Data are stored in the folder: “ Base directory ” \ “ Track ” \ “ Session ” \ “ Vehicle Name ” \ “ Run_name ”
Get M40 — 8 USING M40 WITH A PC diagram (page 15)
Fig. 15
Get M40 — 8 USING M40 WITH A PC diagram (page 15)
Fig. 16

Where:

Base directory: it is the main folder of storage path (the hard disk letter is also included). It is defined by Base directory field in Download Data. The default directory is C:\WinTAXWorkspace. A different path can be selected by click on Base directory selection button.

Track: it is the first sub directory of storage path. User can modify the Track field in Download Data in order to change the directory name. PLEASE NOTE: the directory is always create by the software, the default settings is Track.

Session: it is the second sub directory of storage path. User can modify the Session field in Download Data in order to change the directory name. PLEASE NOTE: the directory is always create by the software, the default settings is Session.

Vehicle Name: it is the third sub directory of storage path. User can modify the Vehicle Name field in data logger configuration (see Config Datalogger section of this manual and the datalogger User Guide for more informations) to set a new folder name.

Run_name: it is the last sub directory of storage path. Its name is Run_ followed to a progressive session index number created by the data logger (in our example it is represented with XXX). Also the Run Comment) text (if it is present) will be added to the folder name.

Page 16 of the Get M40 user manual — 8 USING M40 WITH A PC
Page 16 · click to enlarge
Page 16

The picture below show the Data Storage Settings Area:

Base directory selection button Base

Get M40 — 8 USING M40 WITH A PC diagram (page 16)
Fig. 17

For example the storage path of picture above will be:

c:\WinTAXWorkspace\ Track \ Session \ Car \ Run_XXX_Test

  • Where: Car is set in Vehicle Name field of data logger setup Run_XXX is the progressive index of data
  • At the end of download a message will appear: the device has to be disconnect.
  • Confirm the operation pressing OK : the window of Download Data will disappear. For further information on Download Data use read DATA MANAGER user manual.
Show 4 more labels / short text on this page
Track · Session · Run name · Test
Page 17 of the Get M40 user manual — 8 USING M40 WITH A PC
Page 17 · click to enlarge
Page 17
  • 8.3 Visualizing recorded sessions In order to visualize downloaded sessions you need to use MX2 (the analysis software of DATA MANAGER freeware) and/or WINTAX (require a payment license) Read following instructions:
  • Start MX2 by clicking on the desktop icon:
  • Wait a few seconds: probably will appear demo project (if a new project has not been created).
  • Create a new project by clicking New Project in File menu. NOTE: you can use an old project by selecting Open Project in File menu.
Get M40 — 8 USING M40 WITH A PC diagram (page 17)
Fig. 18

If you use the Demo project you cannot save changes (example: sessions and new channels). For this reason it is suggested to create a brand new project.

Page 18 of the Get M40 user manual — SELECTED TRACK
Page 18 · click to enlarge
Page 18
  • Open Browser Bar and search the needed session in the tree on the left.
  • Select the session in the column File name
  • Apply the track (or create a new one) to the selected session with the track selection window. This is needed to obtain laps’ division (if needed):
Get M40 — SELECTED TRACK diagram (page 18)
Fig. 19
Get M40 — SELECTED TRACK diagram (page 18)
Fig. 20

SELECTED TRACK

“OK” BUTTON

“CREAT NEW TRACK”

BUTTON

NOTE: usually logged data contains information about the track used during the session. Sometimes could happen that this information is missing due to, for example, lack of synchronization of track library with the device. Until you do not associate a track to the session, you will see only lap 0. Once linked the session to the track you will see laps division: this division will be available in all accesses to the same session. Lap times are linked to start-finish line: if you have official lap times and you need to compare directly to logged data it is needed to select a track with a start-finish line as close as possible to the real one. LAPS DIVISION IS UNAVAILABLE WITHOUT GPS INFORMATIONS (IF THE LAP TRIGGER PROPERTY IS SET AS GPS). • If the track is not in the library, or there are more tracks (usually with different start-finish line), for the needed session the window for the selection of the map could appear: you need to select the track between proposed or you need to create a new one with Create New – for the procedure refer to chapter 8.5 of this manual.

Page 19 of the Get M40 user manual — ICON
Page 19 · click to enlarge
Page 19
  • Ad channels by clicking on the icon Channel Bar (under Browser Bar ).
  • You can now analyze data and lines. 8.4 Set the default track in the device To set the default device’s track follow the instructions:
  • Switch on the device (green led fix) and connect to PC ( both led will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger by clicking on the button in starting window of DATA MANAGER .
  • Click the icon Send track on main instrument bar, or select Sync Track Library from Setup menu.

“Send Default Track”

ICON

A message will appear at the end of the operation. PLEASE NOTE: BY SETTING THE DEFAULT TRACK THE LAPS DIVISION WILL BE ALREADY AVAILABLE ON WINTAX SOFTWARE (THIS OPERATION IS NOT NECESSARY FOR MX2 SOFTWARE).

Page 20 of the Get M40 user manual — ICON
Page 20 · click to enlarge
Page 20
  • 8.5 Track creation from a recorded session The creation of new track it is possible by logging data as described in chapter 7.3 . After the download of the session (read chapter 8.2 ) proceed as follows:
  • Open MX2 and create a new project (read chapter 8.3 ).
  • Select the session: software will shows this window.
  • Push Create New button: a new track will be created with the name new_track in Available Tracks list. This track will be without start-finish line, split points and sectors.
  • Define a new start-finish line: click on Finish Line in the left menu
  • Define the line on the track ( FL ) by clicking on the track picture and drag the mouse (keeping left button pressed), and realize the line with needed dimensions. Release mouse button: the start-finish line will be set. The start-finish line must cross the map, otherwise laps won’t be calculated. It is advised to create a perpendicular line to the trajectory with a proper length, not too long (avoiding crossing other parts of the track) not too short (otherwise you could not calculate some laps).
  • If you need to modify a start-finish line, click on the FL and modify it.
Get M40 — ICON diagram (page 20)
Fig. 21
Page 21 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 21 · click to enlarge
Page 21
  • During this operation it is possible to use zoom buttons
  • Define (if needed) intermediates.
  • Save using the “save button”, in order to save new settings: you need to rename the track.
  • Push Apply to use the created track to the session. Now it is possible to synchronize the track into the device as described 8.4 in this manual. For further information on MX2 functions read DATA MANAGER user manual.
Get M40 — TRACK ZOOM BUTTONS diagram (page 21)
Fig. 22

TRACK ZOOM BUTTONS

FINISH LINE (FL)

Page 22 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 22 · click to enlarge
Page 22

8.6 Instrument setup download and updating Device’s setup contains all information relative to sensors calibrations. You should need to change some base parameters. Once done all modification you need to send the table to the device in order to get all modification working.

  • 8.6.1 Instrument setup download and updating with DATA MANAGER software Proceed as follows:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger clicking on the button in starting window of DATA MANAGER .
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger .
Get M40 — TRACK ZOOM BUTTONS diagram (page 22)
Fig. 23

“Open from Device” ICON

Page 23 of the Get M40 user manual — ICON
Page 23 · click to enlarge
Page 23
  • You can now modify and transfer the new setup to the device: click the icon or click Send Setup to Device in Setup menu.
  • You could save the modified setup on to the PC (suggested): select Save as... in File menu. 8.6.2 Instrument setup download and updating with GATE software
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Setup Manager clicking on the button in starting window of GATE.
Get M40 — TRACK ZOOM BUTTONS diagram (page 23)
Fig. 24

“Send Setup to Device”

ICON

Get M40 — ICON diagram (page 23)
Fig. 25
Get M40 — ICON diagram (page 23)
Fig. 26
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.

“Open from Device” ICON

Page 24 of the Get M40 user manual — ICON
Page 24 · click to enlarge
Page 24
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • You can now modify and transfer the new setup to the device: click the icon or click Send Setup to Device in Setup menu.
  • You could save the modified setup on to the PC (suggested): select Save as... in File menu. For further information on Setup Manager and modifications to calibrations read GATE user manual.

“Send Setup to Device”

ICON

Page 25 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 25 · click to enlarge
Page 25
  • 8.7 Starting and stopping logging (MANUAL) If M40 start and stop are set in manual (read chapter 8.9.3 of this manual) it is necessary to start/stop the device with the PC. 8.7.1 Starting and stopping logging (MANUAL) with DATA MANAGER Follows these instructions:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Open Download Data and wait that instrument will be present in Devices and Sessions : select the device with a click
  • Select the device as show in the picture above (one click over the device name).
  • To start the logging press Start Acquis. in the right part of Download Data .
Get M40 — TRACK ZOOM BUTTONS diagram (page 25)
Fig. 27

Test

Page 26 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 26 · click to enlarge
Page 26
  • To stop the logging press Stop Acquis. In the right part of Download Data (after selecting the device in the “Devices and sessions” window. 8.7.2 Starting and stopping logging (MANUAL) with GATE Follows these instructions:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Open Download Manager and wait that the device appears in Devices and Sessions .
  • Select the device as show in the picture.
Get M40 — TRACK ZOOM BUTTONS diagram (page 26)
Fig. 28
Page 27 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 27 · click to enlarge
Page 27
  • To start the logging press Start Acquis. in the right part of Download Manager .
Page 28 of the Get M40 user manual — ICON
Page 28 · click to enlarge
Page 28
  • 8.8 Time syncronization (from pc) 8.8.1 Time syncronization with DATA MANAGER To synchronize M40 clock with the PC, proceed as follow:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Open Config Datalogger . Click “ Send Time” icon on main instrument bar, or select “ Send Time” function in Setup menu. By doing this the device and the PC will show the same time. NOTE : you can do this only if Time Mode is in MANUAL (read chapter 8.9.4 of this manual). 8.8.2 Time syncronization with GATE To synchronize M40 clock with the PC, proceed as follow:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
Get M40 — TRACK ZOOM BUTTONS diagram (page 28)
Fig. 29

ICON

“Send Time”

Page 29 of the Get M40 user manual — ICON
Page 29 · click to enlarge
Page 29
  • Open Setup Manager . Click “ Send Time” icon on main instrument bar, or select “ Send Time” function in Setup menu. By doing this the device and the PC will show the same time. NOTE : you can do this only if Time Mode is in MANUAL (read chapter 8.9.2 of this manual).

ICON

“Send Time”

Page 30 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 30 · click to enlarge
Page 30

8.9 M40 configuration M40 configuration panel permit to modify device parameters and it is the same both in DATA MANAGER and GATE. Configuration panel is on the right part of setup window: In the configuration panel you could set: Acquisition mode Acquisition start/stop (manual or automatic) Clock synchronization mode Lap time triggering mode Source channel of interpolated GEAR Serial protocol type Device CAN speed and protocol WARNING: WRONG SETUP COULD CAUSE MALFUNCTIONING (example DATA LOGGER NOT RECORDING).

Get M40 — TRACK ZOOM BUTTONS diagram (page 30)
Fig. 30
Get M40 — TRACK ZOOM BUTTONS diagram (page 30)
Fig. 31
Page 31 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 31 · click to enlarge
Page 31
  • 8.9.1 M40 configuration with DATA MANAGER To get to the setup panel follow instruction below:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger clicking on the button in starting window of DATA MANAGER .
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger .
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 32 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 32 · click to enlarge
Page 32
  • Click on Setup M40 PLUS at the beginning of channels tree: on the right part of Setup Manager will appear a configuration page of the device (see picture below) 8.9.2 M40 configuration with GATE To get to the setup panel follow instruction below:
  • Switch on the M40 and connect to the PC.
  • Start Setup Manager by clicking the button in GATE .
Page 33 of the Get M40 user manual — ICON
Page 33 · click to enlarge
Page 33
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • The picture below shows an example of a M40 PLUS base setup:

ICON

“Open from Device”

Page 34 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 34 · click to enlarge
Page 34
  • Click on Setup M40 PLUS at the beginning of channels tree: on the right part of Setup Manager will appear a configuration page of the device (see picture below)

8.9.3 Data logging parameters modification M40 logging parameters are in the upper part of configuration panel (see picture below):

Get M40 — TRACK ZOOM BUTTONS diagram (page 34)
Fig. 32
Page 35 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 35 · click to enlarge
Page 35
  • Clicking the parameter you could change the configuration: you could change the value typing or with a dropdown menu (in this case the dropdown will appear after clicking the dots on the right). Available options are:
  • Log Mode: define the logging mode of M40 . Options are: Normal (predefined): data logging will stop only if “stop logging conditions” are satisfied or if the memory is full (green LEDs blinking). It is suggested to leave this setting a sit is. . Loop: data logging will stop each 40 minutes and it will start again erasing old data (“ black box ” mode).
  • Start Channel: define the triggering channel for starting of data logging. Standard setting is MANUAL: start/stop need to be done with PC (see chapter 8.7 of this manual). If yon wish to modify the setting ( AUTOMATIC start) you need to select a channel in the dropdown menu. WARNING: CHANNELS AVAILABLE FOR START/STOP HAVE TO BE LOGGED INTO THE SYSTEM (“logging rate” different from “none”) . The list visualize the physical name of available channels.
  • Start threshold: define the threshold value of the channel to get the logging start. This setting will be effective only if the acquisition starts automatically.
  • Start Condition: define the condition that will start the logging. You could chose between: > = : by selecting this the logging will start when Start Channel will be greater or equal to the threshold defined in Start threshold < = : by selecting this the logging will start when Start Channel will be smaller or equal to the threshold defined in Start threshold
  • Stop Channel: define the channel that will stop the logging. The standard setting is MANUAL: start/stop controls need to be done via PC (read chapter 8.7 of this manual). If you modify M40 ( AUTOMATIC start) the start channel will be stop channel. WARNING: CHANNELS AVAILABLE FOR START/STOP HAVE TO BE LOGGED INTO THE SYSTEM (“logging rate” different from “none”) . The Stop Channel may be different from the Start Channel.
  • Stop threshold: define the threshold value of the channel to get the logging stop. This setting will be effective only if the acquisition stops automatically.
  • Stop Condition: define the condition that will stop the logging. You could chose between: > = : by selecting this the logging will stop when Stop Channel will be greater or equal to the threshold defined in Stop threshold < = : by selecting this the logging will stop when Stop Channel will be smaller or equal to the threshold defined in Stop threshold
  • Stop Log Delay: you could set a delay stop time for the logging (this setting is really to avoid unwanted stops during automatic recording). Values are selectable from dropdown menu.
Get M40 — TRACK ZOOM BUTTONS diagram (page 35)
Fig. 33
Get M40 — TRACK ZOOM BUTTONS diagram (page 35)
Fig. 34
Page 36 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 36 · click to enlarge
Page 36
  • 8.9.4 Change of system time Parameters that configure M40 clock are in the central part of setting panel (see picture below): The modification is done by clicking on the value of the parameter and selecting required value from dropdown menu. Available options are:
  • Time Mode: define the mode with M40 update internal clock (date and hour). Available options are: AUTO (preset): clock update is automatic with GPS system. MANUAL: clock update is manual and comes from PC clock synchronization (read chapter 8.8 of this manual).
  • Time Zone: define internal clock time zone for M40 . Standard setting is 0 (Greenwich time zone). To have a precise hour it is essential to set properly the time zone. In Italy during DST this parameter need to be +2 ; during standard time this parameter will be +1 . 8.9.5 Lap trigger modification Parameters relative to source channel setup for lap triggering in M40 are in the central configuration panel: Lap Trigger is used to cut laps in closed tracks in order to have lap times. If M40 is not linked to any display, this parameter is not really important: MX2 can cut lap times usin GPS signal only. Usually GPS is used for Lap Trigger : other channels can be used only if configured as beacon (read Appendix 1 chapter 2.2 of this manual). 8.9.6 GRSY channel setting Parameters relative to GRSY for interpolated gear in M40 are in the central configuration panel: GRSY can be used only in M40 with a dedicated connected display .
Get M40 — TRACK ZOOM BUTTONS diagram (page 36)
Fig. 35
Get M40 — TRACK ZOOM BUTTONS diagram (page 36)
Fig. 36
Get M40 — TRACK ZOOM BUTTONS diagram (page 36)
Fig. 37
Page 37 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 37 · click to enlarge
Page 37

8.9.7 Serial protocol setting Parameters relative to serial protocol can start data logging through serial port RS232. If it is not connected any device to RS232 port (or the needed protocol is not in the list of recognized protocols) set parameter to None. 8.9.8 CAN parameters setting Parameters relative to CAN configuration permit to set data format and speed of the communication: Available options are: Can1 bitrate: set speed (bitrate) of CAN1 bus, by choosing between proposed values Can1 Byte Order: select data format of CAN1 bus, by choosing between proposed values WARNING: YOU NEED TO KNOW THE CAN PROTOCOL OF YOUR VEHICLE BEFORE MODIFY CAN PARAMETERS.

Get M40 — TRACK ZOOM BUTTONS diagram (page 37)
Fig. 38
Get M40 — TRACK ZOOM BUTTONS diagram (page 37)
Fig. 39
Page 38 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 38 · click to enlarge
Page 38
  • 8.10 M40 setup properties modification In setup window you can modify following M40 parameters: GPS configuration Adding comments (available only in GATE software) Adding driver’s name Adding vehicle’s name Last three voices can change also the name of logging file downloaded by the PC with Download Manager (read chapter 8.2 of this manual) 8.10.1 M40 setup properties modification with DATA MANAGER To get to the setup panel follow instruction below:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger clicking on the button in starting window of DATA MANAGER .
Get M40 — TRACK ZOOM BUTTONS diagram (page 38)
Fig. 40
Get M40 — TRACK ZOOM BUTTONS diagram (page 38)
Fig. 41
Page 39 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 39 · click to enlarge
Page 39
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger .
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 40 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 40 · click to enlarge
Page 40
  • Click on Setup M40 PLUS at the beginning of channels tree: on the right part of Config Datalogger will appear a configuration page of the device (see picture below)
  • 8.10.2 M40 setup properties modification with GATE To get to the panel control follow the instruction below:
  • Switch on M40 and connect to a PC.
  • Start Setup Manager by clicking the button on GATE main page.
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.

“Open from Device” ICON

Setup properties · Active setup window

Page 41 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 41 · click to enlarge
Page 41
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • The picture below show san example of a M40 PLUS base setup:
  • Click on Setup M40 PLUS at the beginning of channels tree: on the right part of Setup Manager will appear a configuration page of the device (see picture below)
Get M40 — TRACK ZOOM BUTTONS diagram (page 41)
Fig. 42

Setup properties · Active setup window

Page 42 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 42 · click to enlarge
Page 42

8.10.3 GPS parameters setting GPS parameters can change behaviour of M40: PLEASE ACT CAREFULLY WHEN DOING THESE OPERATIONS. The following picture shows GPS configuration:

GPS Configuration: this parameter change the dynamic of GPS module. Standard configuration is CONF4. We suggest CONF6 in off-road applications WARNING: WRONG SETUP COULD CAUSE MALFUNCTIONING (example DATA LOGGER NOT RECORDING OR BAD GPS TRAJECTORIES).

Get M40 — TRACK ZOOM BUTTONS diagram (page 42)
Fig. 43

8.10.4 Comment, driver and vehicle setting Comments, driver’s name and vehicle’s name can be changed in order to achieve a easier M40 file management (this important when using more than one M40). These are available configurations:

Comment (only for GATE software): you can add a comment Driver Name : you can add a driver’s name Vehicle name : you can add vehicle’s name All changes done in the previous parameters will affect file name downloaded with Download Manager.

Get M40 — TRACK ZOOM BUTTONS diagram (page 42)
Fig. 44
Page 43 of the Get M40 user manual — TRACK ZOOM BUTTONS
Page 43 · click to enlarge
Page 43

8.11 Firmware update M40 firmware can be updated via the PC. To update firmware please act as follows: Switch on M40 and connect to the PC with USB cable. Update the firmware by clicking on the firmware auto-executable icon. Push UPDATE and confirm: wait until the end of the procedure (a message will appear in the PC monitor).

Get M40 — TRACK ZOOM BUTTONS diagram (page 43)
Fig. 45
Page 44 of the Get M40 user manual — 9 M40 TECHNICAL CHARACTERISTICS
Page 44 · click to enlarge
Page 44

9 M40 TECHNICAL CHARACTERISTICS

Power: Power range: from 9 VDC to 24 VDC Consumption: 170mA @ 12VDC (device switched on, sensors not connected, alarms LEDs switched of,

GPS aerial not connected) System I/O:

Analogue inputs (range 0-5V) Frequency inputs (open collector 0-5V , freq. 0 - 20kHz) 1 input for button connection or external beacon (only in M40 EXP and PLUS) with internal 5V pull up 2 auxiliary power supplies (5V and 12V ) Integrated tri-axial accelerometer Communication ports:

1 2.0 High Speed CAN port (bitrates 125 kb/s, 250 kb/s, 500 kb/s, 1Mb/s; Intel and Motorola protocols)

transmitting or receiving configurable USB port for connection with PC GPS module: Integrated 5Hz GPS module (oversampled @ 10 Hz) with external antennal (supplied) SMA antenna connector Miscellaneous: Internal SD memory up to 16GB Integrated signalling LEDs Anodized aluminium machined case Protection grade: IP68 Dimensions (mm) 92 x 66 x 20 Weight: 250 g (circa)

Page 45 of the Get M40 user manual — 9 M40 TECHNICAL CHARACTERISTICS
Page 45 · click to enlarge
Page 45
  • APPENDIX 1: M40 SETUP Some examples here described will help the end user to add new channels into M40 PLUS setup and the use of WATCH window. Each sensor physically connected to the datalogger need to be defined and calibrated into the setup, stored in the device. Sensors have to be linked to specific “ channels ” that, for M40 , can be resumed as follows:
  • Analogue Channels: these channels can be used with analogue sensors that transform analogue signals (0 V - 5 V), as potentiometer, pressure transducers, thermocouples, etc. M40 uses these connectors for analogue sensors connection: AD1 , AD2 , AD3 , etc (inside EXPANSION cable)
  • System Channels: system channel that should not be changed by the user.
  • Switch Channels: these channels can be used to detect the pressure of buttons (map switch, for example). This channel is available only in M40 PLUS with EXP2 connector.
  • GPS Channels: GPS channel system that should not be changed by the user.
  • CAN Channels: CAN BUS channels.
  • Input Capture Channels: these channels can be linked to frequency channels as, for example, ignition pick up (rpm detection) or proximity sensors (wheel speed sensor). For further information on GET sensors and calibration, read attached technical sheet and specification. Following chapters show software channel configuration; for hardware configuration please refer to appendix 2 of this manual. When writing/reading setups to/from the M40 the device must be connected to the PC. Please make sure that the M40 is not logging.
Page 46 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 46 · click to enlarge
Page 46

1 ANALOGUE CHANNELS

  • Here you can find some instruction to create analogue channels. 1.1 Linear calibration example This chapter will show how calibrate a generic linear sensor with an analogue output (0 - 5 Volt). This calibration is usually done with temperature sensors, pressure sensors, potentiometers, accelerometers. If the linear calibration has been used for a suspension potentiometer the user can run the WATCH function to set the “zero” of suspension sensor The following table shows characteristic of a generic temperature sensors: Let’s suppose the this sensor is used to log the engine temperature. In order to set this sensor in the list of logged channels, refer to follows chapters. 1.1.1 Linear calibration by using DATA MANAGER To set the channel follow instruction below:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger clicking on the button in starting window of DATA MANAGER .
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.

Temperature (°C) Output (V) 25 1.8 60 2 70 2.5 80 2.8 100 3.6 110 4 120 4.5

“Open from Device” ICON

Page 47 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 47 · click to enlarge
Page 47
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger .
  • The picture below shows an example of a M40 PLUS base setup:
Get M40 — 1 ANALOGUE CHANNELS diagram (page 47)
Fig. 46
  • If, for example, the sensor is connected to AD1 ; click on AD1 (in Analogue Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is TENG – Engine Temperature). Unit: this parameter define measurement unit of the channel (°C for temperature sensor)
Page 48 of the Get M40 user manual — ICON
Page 48 · click to enlarge
Page 48
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use Linear ) X values: values, COUNT or VOLTAGE , of the channel Y values: define calibrated values of the relative X values. In our example at 25°C (value Y1 ) we will read 1.8 V (value X1 ) Setup Manager permit to log X values, directly from the device using Pick 2 . Y values need to be known.
Get M40 — 1 ANALOGUE CHANNELS diagram (page 48)
Fig. 47
  • COUNT : digital value associated to the channel VOLT : volt value associated to the channel. Volt visualization need to be activated by selecting “Show input as Voltage” box.
  • Once calibration values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu. 2 This option is available on if M40 is on and connected to PC via USB

“Send Setup to Device”

ICON

Page 49 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 49 · click to enlarge
Page 49
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. 1.1.2 Linear calibration by using GATE To set the channel follow instruction below:
  • Start Setup Manager by clicking the button in GATE .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 50 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 50 · click to enlarge
Page 50
  • If, for example, the sensor is connected to AD1 ; click on AD1 (in Analogue Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is Engine Temp ). Unit: this parameter define measurement unit of the channel (°C for temperature sensor)
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
Page 51 of the Get M40 user manual — ICON
Page 51 · click to enlarge
Page 51
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use Linear ) X values: values, COUNT or VOLTAGE , of the channel Y values: define calibrated values of the relative X values. In our example at 25°C (value Y1 ) we will read 1.8 V (value X1 ) Setup Manager permit to log X values, directly from the device using Pick 2 . Y values need to be known.
  • COUNT : digital value associated to the channel VOLT : volt value associated to the channel. Volt visualization need to be activated by selecting “Show as Voltage” box.
  • Once calibration values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. For further information on Setup Manager read Gate user manual. 2 This option is available on if M40 is on and connected to PC via USB

“Send Setup to Device”

ICON

Page 52 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 52 · click to enlarge
Page 52
  • 1.2 GEAR on analogue input calibration This chapter will help you to calibrate a “GEAR” sensor: this calibration is used when a 0-5 volt potentiometer is used to log the position of the gear barrel. Please refer to follows instructions. 1.2.1 GEAR on analogue input calibration by using GATE To set the channel follow instruction below:
  • Switch on the device (green led on fix) and connect to the PC (both LEDs will blink).
  • Verify that all condition of 8.1 are satisfied.
  • Wait until the device is recognized by Windows (usually the message in the low right part of the screen).
  • Start Config Datalogger clicking on the button in starting window of DATA MANAGER .
  • Download device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger .

“Open from Device” ICON

Page 53 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 53 · click to enlarge
Page 53
  • The picture below shows an example of a M40 PLUS base setup:
  • If, for example, the sensor is connected to AD1 ; click on AD1 (in Analog Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (set None for this case) Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is GEAR SENSOR ). Unit: this parameter define measurement unit of the channel (in this case there will be nothing)
Page 54 of the Get M40 user manual — ICON
Page 54 · click to enlarge
Page 54
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use GEAR ) X values: values, COUNT or VOLTAGE , of the channel Y values: define calibrated values of the relative X values. In our example 1 st gear (value Y1 ) correspond to the analogue value of 0 V (value X1 ), neutral (value Y7=0 ) is 5V or 65535 COUNT (value X7 ) Setup Manager permit to log X values, directly from the device using Pick 3 . Y values need to be known.
Get M40 — 1 ANALOGUE CHANNELS diagram (page 54)
Fig. 48
  • COUNT : digital value associated to the channel VOLT : volt value associated to the channel. Volt visualization need to be activated by selecting “Show input as Voltage” box.
  • Once calibration values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.

“Send Setup to Device”

ICON

3 This option is available on if M40 is on and connected to PC via USB

Page 55 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 55 · click to enlarge
Page 55
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. WARNING: values that will be set in Y fields are referred to number of gears of the gearbox. The value 0 in a Y field will be NEUTRAL, the value 10 will be the reverse (if present).
  • 1.2.2 GEAR on analogue input calibration by using GATE Proceed as follows:
  • Start Setup Manager by clicking the button in GATE .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .

“Open from Device” ICON

Page 56 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 56 · click to enlarge
Page 56
  • The picture below shows an example of a M40 PLUS base setup:
  • If, for example, the sensor is connected to AD1 ; click on AD1 (in Analog Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (set None for this case) Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is GEAR SENSOR ). Unit: this parameter define measurement unit of the channel (in this case there will be nothing)
Page 57 of the Get M40 user manual — ICON
Page 57 · click to enlarge
Page 57
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use GEAR ) X values: values, COUNT or VOLTAGE , of the channel Y values: define calibrated values of the relative X values. In our example 1 st gear (value Y1 ) correspond to the analogue value of 0 V (value X1 ), neutral (value Y7=0 ) is 5V or 65535 COUNT (value X7 ) Setup Manager permit to log X values, directly from the device using Pick 3 . Y values need to be known.
  • COUNT : digital value associated to the channel VOLT : volt value associated to the channel. Volt visualization need to be activated by selecting “Show as Voltage” box.
  • Once calibration values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.

“Send Setup to Device”

ICON

3 This option is available on if M40 is on and connected to PC via USB

Page 58 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 58 · click to enlarge
Page 58
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. For further information on Setup Manager read Gate user manual. WARNING: values that will be set in Y fields are referred to number of gears of the gearbox. The value 0 in a Y field will be NEUTRAL, the value 10 will be the reverse (if present).
Page 59 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 59 · click to enlarge
Page 59
  • 1.3 TPS setup (available only for GATE software) To insert the TPS sensor inside M40 setup we suggest to download the setup from the device:
  • Start Setup Manager by clicking the button in GATE .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 60 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 60 · click to enlarge
Page 60
  • If, for example, TPS is connected to AD1 ; click on AD1 (in Analogue Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (usually None for TPS) Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is TPS ). Unit: this parameter define measurement unit of the channel (usually % for TPS)
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
Get M40 — 1 ANALOGUE CHANNELS diagram (page 60)
Fig. 49
Page 61 of the Get M40 user manual — ICON
Page 61 · click to enlarge
Page 61
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use TPS ) Min : this parameter define the minimum value of the channel in order to get the zero in the acquisition Max : this parameter define the maximum value of the channel in order to get 100 Setup Manager permit to log Min and Max , directly from the device, using Pick 1 .

In order to define Min and Max value you need to select the box and type the value manually, or by clicking Pick1.

In this example, while setting Min throttle need to be closed and while setting Max throttle need to be fully open.

  • COUNT : digital value associated to the channel VOLT : volt value associated to the channel. Volt visualization need to be activated by selecting “Show as Voltage” box.
  • Once limit values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. For further information on Setup Manager read Gate user manual.

“Send Setup to Device”

ICON

1 This option is available on if M40 is on and connected to PC via USB

Page 62 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 62 · click to enlarge
Page 62
  • 1.4 Suspension potentiometer setting (available only for GATE software) Suspension movements are studied with a linear potentiometer. Before calibrate the channel, we suggest to download the setup from the device:
  • Start Setup Manager by clicking the button in GATE .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 63 of the Get M40 user manual — 1 ANALOGUE CHANNELS
Page 63 · click to enlarge
Page 63
  • If, for example, the linear potentiometer is connected to AD1 ; click on AD1 (in Analog Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (usually None for suspension potentiometers) Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is FORK ). Unit: this parameter define measurement unit of the channel (usually mm for this channel)
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
Get M40 — 1 ANALOGUE CHANNELS diagram (page 63)
Fig. 50
Page 64 of the Get M40 user manual — ICON
Page 64 · click to enlarge
Page 64
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use POT ) Pot Length : this parameter define the total length (in mm) of the installed sensor (in this example 150 )
  • Once limit values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu. For further information on Setup Manager read Gate user manual. WARNING: for POT it is necessary to set zero point. This action could be done using WATCH in Setup Manager (for further information read Appendix 1 chapter 5 of this manual and chapter 5.4 of GATE user manual).

“Send Setup to Device”

ICON

Page 65 of the Get M40 user manual — ICON
Page 65 · click to enlarge
Page 65

2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS)

  • This chapter will guide the user to the functionalities of SWITCH channel. SWITCH channels could be used to log signals from:
  • buttons: the signal applied to the SW input is a pulse (voltage changes once the button is pressed and end once the button is released)
  • switch: the signal has got two different status depending on switch position
  • beacon: the signal applied to the SW input comes from an external IR receiver (beacon) for lap triggering. From the electrical point of view, SWITCH input are 5 volt pull up. 2.1 Adding a SWITCH MAP-SWITCH BUTTON channel First of all we suggest to save device setup in to the PC:
  • Start Config Datalogger (or Setup Manager you are using GATE ) by click on software start panel .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger (or Setup Manager ).

ICON

“Open from Device”

Page 66 of the Get M40 user manual — 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS)
Page 66 · click to enlarge
Page 66
  • The picture below shows an example of a M40 PLUS base setup:
  • Configure SW1 by clicking on SW1 in the Switch Channels list
  • If, for example, the button is connected to SW1 of EXP1 wiring; click on SW1 (in Switch Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (set None for this case) Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Name: channel’s name (in this example is SW ). Unit: this parameter define measurement unit of the channel (in this case there will be nothing)
Get M40 — 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS) diagram (page 66)
Fig. 51
Page 67 of the Get M40 user manual — 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS)
Page 67 · click to enlarge
Page 67
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration. For SWITCH channel we can use: MAP SWITCH: this setting need to be used with 2-position switches: X values: switch status, the value could be 0 and 1 Y values: define calibrated values of the relative X values. If we have, for example, a 2-positions map switch that could vary from 0 V( map 1) and 12 V (map 2): map 1 (value Y1=2 ) is the value 0 (value X1 ), map 2 (value Y2=2 ) is value 1 (value X2 )
Get M40 — 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS) diagram (page 67)
Fig. 52

NOTE: in column Y you could add only numeric values. MAP BUTTON: this setting need to be used with buttons. Active Edge: specify the activation edge for the button. Set value to 0 if button is connected to the ground when activated (0V); set value to 1 if button is positive when activated (example 12 V). Button Mask: inhibition time (milliseconds) of the status control after the button is pressed.. this parameter is needed to avoid wrong readings and signals “jumps”: a classical example is a button that need to be pressed some seconds to activate the function. If Button Mask is low M40 could detect two or more activation instead of one. To avoid this you could set the parameter to 1000 (1 second). Y values: define calibrated values. If we connected a switch with three positions, in Y1, Y2, Y3 we will add 1, 2, 3 • Once calibration values are defined, click OK to get back to M40 setup window

Page 68 of the Get M40 user manual — ICON
Page 68 · click to enlarge
Page 68
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu.

“Send Setup to Device”

ICON

Page 69 of the Get M40 user manual — 2 SWITCH CHANNELS (ONLY M40 EXPANSION AND PLUS MODELS)
Page 69 · click to enlarge
Page 69
  • 2.2 Adding a BEACON channel Adding a beacon channel will permit to use a IR receiver for lap triggering. The use of this kind of sensor permit lap triggering also without GPS signal. In order to set a beacon channel follow instruction below:
  • Start Config Datalogger (or Setup Manager you are using GATE ) by click on software start panel .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger (or Setup Manager ).
  • The picture below shows an example of a M40 PLUS base setup:

“Open from Device” ICON

Page 70 of the Get M40 user manual — BEACO
Page 70 · click to enlarge
Page 70
  • Configure SW1 channel by clicking on the Switch Channels list
  • If, for example, the button is connected to SW1 of EXP1 wiring; click on SW1 (in Switch Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have (set None for this case) Logging rate: set None . The logging frequency will be updated automatically once the calibration is defined Name: channel’s name (in this example is BEACON ). Unit: this parameter define measurement unit of the channel (in this case there will be nothing)
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:

BEACO

BEACON

Get M40 — BEACO diagram (page 70)
Fig. 53

500 Hz

Page 71 of the Get M40 user manual — ICON
Page 71 · click to enlarge
Page 71
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration. For BEACON channel use beacon . Seconds: this is the “ blind time ” and it is used to avoid wrong lap triggering coming from more than one wall beacon transmitter.
  • Once calibration values are defined, click OK to get back to M40 setup window
  • Set the lap trigger option as SW1:

SW1

  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu.

“Send Setup to Device”

ICON

Page 72 of the Get M40 user manual — 3 CAN CHANNELS
Page 72 · click to enlarge
Page 72

3 CAN CHANNELS

  • In this chapter you will have deep information on CAN channels setup. We need to:
  • Define protocol and bus speed
  • Define channel properties All operations depend on CAN bus used from all devices connected to M40 datalogger: it is necessary know data format prior to configure CAN channels . CAN Bus connector is available in MAIN wiring of M40 . 3.1 Adding a CAN channel First of all we suggest to save device setup in to the PC:
  • Start Config Datalogger (or Setup Manager you are using GATE ) by click on software start panel .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger (or Setup Manager ).

“Open from Device” ICON

Page 73 of the Get M40 user manual — 3 CAN CHANNELS
Page 73 · click to enlarge
Page 73
  • The picture below shows an example of a M40 PLUS base setup:
  • Click Setup M40 PLUS : on right side of window will be available settings for protocol and bus speed (picture below):
Page 74 of the Get M40 user manual — 3 CAN CHANNELS
Page 74 · click to enlarge
Page 74
  • Now you can change all options: Can1 bitrate: with this parameter you could set bus CAN1 bitrate between available values Can1 Byte Order : with this parameter you could set CAN1 data format between available values
  • You can now change properties by clicking the name of the channel needed, under CAN Channels list
  • Now you can change all options:
Get M40 — 3 CAN CHANNELS diagram (page 74)
Fig. 54

Can Message ID: define ID number of channel message. WARNING: ID number could be decimal base or hexadecimal!!! It is possible to change ID numerical base (decimal to hexadecimal) by selecting the box above Calibrate Channel button.

Get M40 — 3 CAN CHANNELS diagram (page 74)
Fig. 55

Origin/Destination: this parameter define the position (inside CAN message) that contains first data bit to be associated to the channel. Channel Length: define bit length of CAN message Signed: you can define if the channel has got a sign. This is essential when configuring signals that could be positive or negative. Available options are Yes or No. Name: define channel name. In this case CAN1. Decimal Places: how many decimal places you wish to have (set None for this case) Unit: define channel measurement unit

Page 75 of the Get M40 user manual — 3 CAN CHANNELS
Page 75 · click to enlarge
Page 75
  • Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Channel Type : this parameter define the type of used CAN channel. You could set CAN RX (to log and visualize the channel) or CAN TX (to transmit the channel onto the vehicle CAN bus). Source Index: this parameter defines the source of the channel. If the channel comes from the vehicle CAN bus (from the ECU, for example) you need to set CAN_RX . If you set an other source (list on the right of white box), values will be sent also on CAN channel that you are setting. This is really useful if you wish to send through CAN bus an analogue value. In this case you need to set Channel Type as CAN TX . TX Rate: define channel transmitting frequency. This option need to be None if Channel Type is CAN RX . Can Port Number: this parameter define the port number in which the CAN bus is connected (typically 1). Can Type: this parameter define CAN data format. You have two options: Normal (11 bit) and Extended (29 bit) .
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration. For CAN channels you could chose between: None : no calibration, the value is visualized/logged as it comes from the CAN bus. Linear : channel value is visualized/logged with the calibration curve defined by X and Y values (for further information read chapter 1.1 Appendix 1 of this manual) GEAR : channel value is visualized/logged with the calibration “GEAR” (for further information read chapter 1.2 Appendix 1 of this manual).
Get M40 — 3 CAN CHANNELS diagram (page 75)
Fig. 56
Page 76 of the Get M40 user manual — ICON
Page 76 · click to enlarge
Page 76
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu.

“Send Setup to Device”

ICON

Page 77 of the Get M40 user manual — 4 INPUT CAPTURE CHANNELS (IC CHANNELS)
Page 77 · click to enlarge
Page 77

4 INPUT CAPTURE CHANNELS (IC CHANNELS)

  • This chapter will show how to set an IC channel in M40 . IC channels are, for examples:
  • Proximity sensors, as wheel speed sensors
  • Engine speed (RPM) IC channels have frequency domain signals and an minimum amplitude between 0 and 5 V. 4.1 IC channel calibration (connected to a wheel speed sensor) Instruction below are for M40 PLUS setup. The same procedure could be used in M40 STANDARD and EXPANSION. In order to put this sensor in IC channel list, follow steps below:
  • Start Config Datalogger (or Setup Manager you are using GATE ) by click on software start panel .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger (or Setup Manager ).

“Open from Device” ICON

Page 78 of the Get M40 user manual — 4 INPUT CAPTURE CHANNELS (IC CHANNELS)
Page 78 · click to enlarge
Page 78
  • The picture below shows an example of a M40 PLUS base setup:
  • If, for example, the sensor is connected to IC1 (in EXP wiring loom); click on IC1 (in Input Capture Channels list): channel’s properties will appear.
  • Now you can change all options: Decimal Places: how many decimal places you wish to have. In this example set None . Logging rate: logging frequency. If this parameters is None , the channel will not be logged and it will not be available in analysis software. Set 100 Hz for this example. Name: channel’s name (in this example is SPDR – Speed Rear ). Unit: this parameter define measurement unit of the channel (kph for speed)
Get M40 — 4 INPUT CAPTURE CHANNELS (IC CHANNELS) diagram (page 78)
Fig. 57
Page 79 of the Get M40 user manual — 4 INPUT CAPTURE CHANNELS (IC CHANNELS)
Page 79 · click to enlarge
Page 79
  • We need now to proceed with the channel calibration. This operation is needed in order to have a proper logging signal. Click on Calibrate Channel (low right part of the screen), a calibration window will appear:
  • Once you get in to the calibration window it is necessary to define: Calibration Type : you can chose the type of calibration (in this example use SPEED ) Teeth per round : this is the number of electrical pulses given by the sensor each wheel revolution. Usually the sensor reads brake disk fixing bolts: in this case you need only to type the correct number in the dedicated box Wheel diam mm : this is the wheel diameter, in mm. You could calculate this dividing the circumference by 3,14.
Get M40 — 4 INPUT CAPTURE CHANNELS (IC CHANNELS) diagram (page 79)
Fig. 58
Get M40 — 4 INPUT CAPTURE CHANNELS (IC CHANNELS) diagram (page 79)
Fig. 59
Page 80 of the Get M40 user manual — ICON
Page 80 · click to enlarge
Page 80

Clicking in Motorcycle Type box some “default” parameters will appear: if you motorbike is not in the list you need to type manually all parameters.

Phonic wheel tooth : teeth number of target wheel Rack tooth : crown teeth number Pinion tooth : pinion teeth number Wheel diam mm : this is the wheel diameter, in mm. You could calculate this dividing the circumference by 3,14.

Once the operation are completed, press Calculate (in Tooth number and Equivalent diameter appears calibration values). After this, press Apply to confirm data and get back to the configuration window.

  • Once calibration values are defined, click OK to get back to M40 setup window
  • You need to write the new modified setup to the device: click the icon or Send Setup to Device in Setup menu.
  • We suggest to save the new modified setup in to the pc: select Save as... in File menu.

“Send Setup to Device”

ICON

Page 81 of the Get M40 user manual — 4 INPUT CAPTURE CHANNELS (IC CHANNELS)
Page 81 · click to enlarge
Page 81

4.2 IC channel calibration (connected to a RPM sensor) If a RPM signal is connected to the IC input, repeat all steps already seen regarding download and opening of setup. • Once you get in to the calibration window it is necessary to define:

Calibration Type : you can chose the type of calibration (in this example use RPM) Teeth for two: this is the number of electrical pulses given by the sensor each two flywheel revolutions. If you do not know this parameter, you need to try until you get the correct RPM reading

Page 82 of the Get M40 user manual — 5 “WATCH” function
Page 82 · click to enlarge
Page 82

5 “WATCH” function

  • With WATCH , in Setup Manager you can:
  • Read live sensors values
  • Calibrate sensors
  • Set 0 (really useful in cases, as suspension potentiometer, when the value can be positive or negative)
  • Set offset Using WATCH it is compulsory to switch on and connect M40 to PC (read chapter 8.1 of this manual). 5.1 Start and stop “WATCH”: real time channel visualization This procedure shows visualization of two analogue channels: operations are the same for all of M40 parameters. Start WATCH as described:
  • Start Config Datalogger (or Setup Manager you are using GATE ) by click on software start panel .
  • Save device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Config Datalogger (or Setup Manager ).

“Open from Device” ICON

Page 83 of the Get M40 user manual — “WATCH” ICON
Page 83 · click to enlarge
Page 83
  • The picture below shows an example of a M40 PLUS base setup:
  • Click on WATCH icon to see channels list visualization
Get M40 — “WATCH” ICON diagram (page 83)
Fig. 60

“WATCH” ICON

Get M40 — “WATCH” ICON diagram (page 83)
Fig. 61
Page 84 of the Get M40 user manual — “WATCH” ICON
Page 84 · click to enlarge
Page 84
  • If we wish to read live AD1 and VBAT channels, we select boxes in Watch column
  • Click on Start Watch in “instrument bar” or select Start Watch in Watch menu: the software will show selected values.
Get M40 — “WATCH” ICON diagram (page 84)
Fig. 62
Get M40 — “WATCH” ICON diagram (page 84)
Fig. 63

“Start Watch” ICON

Page 85 of the Get M40 user manual — “WATCH” ICON
Page 85 · click to enlarge
Page 85
  • In order to freeze WATCH , click again Active Watch , or select Stop Watch in Watch menu NOTE: the value, visualized in WATCH, is given by channel calibration. WARNING: to get back to Setup Manager window, click on the icon on the left of the WATCH window

“Active Watch” ICON · “Setup Manager” ICON

Page 86 of the Get M40 user manual — “WATCH” ICON
Page 86 · click to enlarge
Page 86

5.2 “WATCH” channel calibration Calibration is necessary to convert signals from sensors to comprehensible data. This operation can be done during the channel creation (read previous chapters) or in WATCH window, clicking on Calibrate button (corresponding to the required channel) without starting WATCH . We suggest to use this function only after the channel is configured in M40 setup.

Get M40 — “WATCH” ICON diagram (page 86)
Fig. 64

Once the button Calibrate is pressed, you will see the calibration window. The procedures are the same of previous chapters. Once the channel is calibrated, you need to send again the setup to the device. You can do this directly from WATCH selecting “Send Setup to Device” in File menu o by clicking the icon (second from the left in instrument bar).

Get M40 — “WATCH” ICON diagram (page 86)
Fig. 65
Page 87 of the Get M40 user manual — “WATCH” ICON
Page 87 · click to enlarge
Page 87

5.3 Setting channel zero in “WATCH” Zero set is useful when using some kind of sensor (for example suspension potentiometer or internal accelerometer). To use this function WATCH need to be activated (read chapter 5.1 of this Appendix) and the sensor need to be in “zero” position. To set the zero, press “Set Zero” of the required channel We suggest to send back the setup once “zero” operation are finished. We suggest to use this function only after the channel is configured in M40 setup.

Get M40 — “WATCH” ICON diagram (page 87)
Fig. 66
Get M40 — “WATCH” ICON diagram (page 87)
Fig. 67
Page 88 of the Get M40 user manual — “WATCH” ICON
Page 88 · click to enlarge
Page 88

5.4 Setting channel offset in “WATCH” Sometimes it is needed to add or remove a defined value from a sensor reading (wrong “zero” of a suspension potentiometer). To set this we will use the Offset button: Set the value in dialogue box: Use negative values to add the offset to the channel value and use positive values to subtract; press OK to confirm.

Get M40 — “WATCH” ICON diagram (page 88)
Fig. 68
Page 89 of the Get M40 user manual — 1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS)
Page 89 · click to enlarge
Page 89

APPENDIX 2: CONNECTORS M40 STD. – EXP. - PLUS Following chapters will show pinout of all connector in M40.

1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS)

MAIN pinout of M40:

Front view (wiring get out from rear part)

Get M40 — 1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS) diagram (page 89)
Fig. 69
Get M40 — 1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS) diagram (page 89)
Fig. 70

Pin Signal name Description Setup Manager name 1 VBAT Positive power VBAT 2 GND POW Negative power - 3 CANL CANL input - 4 CANH CANH input - 5 GND SEN Sensor reference - 6 RX M40 RS232 serial RX - 7 TX M40 RS232 serial TX - 8 EN-BLES “battery less” input -

Get M40 — 1 “MAIN” CONNECTOR (M40 STD. - EXP. - PLUS) diagram (page 89)
Fig. 71

MAIN connector

Page 90 of the Get M40 user manual — 3 “EXP1” CONNECTOR (ONLY M40 EXP. - PLUS)
Page 90 · click to enlarge
Page 90

2 “EXP” CONNECTOR (M40 STD. - EXP. - PLUS)

EXP pinout of M40:

Front view (wiring get out from rear part)

Get M40 — 2 “EXP” CONNECTOR (M40 STD. - EXP. - PLUS) diagram (page 90)
Fig. 72
Get M40 — 2 “EXP” CONNECTOR (M40 STD. - EXP. - PLUS) diagram (page 90)
Fig. 73

1 VBB1 Auxiliary power (same as power voltage) - 2 GND SEN GND sensors - 3 AN1 Analogue input 1 AD1 4 AN2 Analogue input 2 AD2 5 AN3 Analogue input 3 AD3 6 IC1 Frequency input 1 IC1 7 IC2 Frequency input 2 IC2 8 VREF Auxiliary power (5 VDC) -

3 “EXP1” CONNECTOR (ONLY M40 EXP. - PLUS)

EXP1 pinout of M40 EXPANSION and PLUS:

Front view (wiring get out from rear part)

Get M40 — 3 “EXP1” CONNECTOR (ONLY M40 EXP. - PLUS) diagram (page 90)
Fig. 74

1 VBB1 Auxiliary power (same as power voltage) - 2 GND SEN GND sensors - 3 AN4 Analogue input 4 AD4 4 AN5 Analogue input 5 AD5 5 AN6 Analogue input 6 AD6 6 IC3 Frequency input 3 IC3 7 SW1 Switch input SW1 8 VREF Auxiliary power (5 VDC) -

EXP connector · EXP1 connector

Page 91 of the Get M40 user manual — 4 “EXP2” CONNECTOR (ONLY M40 PLUS)
Page 91 · click to enlarge
Page 91

4 “EXP2” CONNECTOR (ONLY M40 PLUS)

EXP2 pinout of M40 PLUS:

Front view (wiring get out from rear part)

Get M40 — 4 “EXP2” CONNECTOR (ONLY M40 PLUS) diagram (page 91)
Fig. 75

1 VBB1 Auxiliary power (same as power voltage) - 2 GND SEN GND sensors - 3 AN7 Analogue input 7 AD7 4 AN8 Analogue input 8 AD8 5 AN9 Analogue input 9 AD9 6 IC4 Frequency input 4 IC4 7 IC5 Frequency input 5 IC5 8 VREF Auxiliary power (5 VDC) -

USB pinout of M40:

Front view (wiring get out from rear part)

Get M40 — 4 “EXP2” CONNECTOR (ONLY M40 PLUS) diagram (page 91)
Fig. 76
Get M40 — 4 “EXP2” CONNECTOR (ONLY M40 PLUS) diagram (page 91)
Fig. 77

1 USB + USB +5V connection 2 USB P USB N connection 3 USB N USB P connection 4 USB - USB GND connection

EXP2 connector · USB connector

Page 92 of the Get M40 user manual — BATTERY LESS SWITCH
Page 92 · click to enlarge
Page 92
APPENDIX 3WIRING LOOMS FOR M40 CONNECTION Following chapter illustrate optional M40 wiring

1 MULTILINK WIRING code GL-0018-AA

  • Connectors position in MULTILINK wiring loom code GL-0018-AA
  • GP-LC1 MAIN CONNECTOR: input for the connection of ECU GP1 EVO or lambda module LC1-EVO
  • VT1-PC CONNECTOR: input for the connection of VT1 configurator or ECU setting cable GP1 EVO
  • LOGGER CONNECTOR: input for the connection of M40 datalogger ( MAIN connector).
  • BATTERY LESS SWITCH: this switch is a cable that connect EN-BLES to the ground: the datalogger switch on is delayed about 10 seconds in order to get the system ready (offroad motorbikes). A wrong power of the devices could cause a malfunctioning of the system. If you do not need the delay, cut the cable.

ECU CONNECTOR (example GP1 EVO)

VT1 or PC connector

Get M40 — 1 MULTILINK WIRING code GL-0018-AA diagram (page 92)
Fig. 78 · 1 MULTILINK WIRING code GL-0018-AA

BATTERY LESS SWITCH

DATALOGGER M40

CONNECTOR

(only GP1 EVO)

Page 93 of the Get M40 user manual — IC1; IC2
Page 93 · click to enlarge
Page 93

2 EXPANSION WIRING code GL-0041-AA

Connector position in EXPANSION wiring loom code GL-0041-AA. This wiring loom has to be connected to EXP (M40 datalogger).

Get M40 — 2 EXPANSION WIRING code GL-0041-AA diagram (page 93)
Fig. 79 · 2 EXPANSION WIRING code GL-0041-AA

ANALOGUE INPUT AD1

EXP CONNECTOR

ANALOGUE INPUT AD2

ANALOGUE INPUT AD3

FREQUENCY INPUT IC1

FREQUENCY INPUT IC2

1 + 5 VDC (VREF) 2 Input 3 Ground (GND SEN)

AD1; AD2;

AD3

1 +12 VDC (VBB1) 2 Input 3 Ground (GND SEN)

IC1; IC2

  • CONNECTOR EXP: you need to connect this to EXP connector of M40
  • CONNECTORS AD1…AD3: analogue inputs (example: potentiometer, thermocouples, etc)
  • CONNECTORS IC1IC2: frequency input (example: wheel speed sensors, rpm, etc)

Connector · Pin number Description · name

Page 94 of the Get M40 user manual — IC3; SW1
Page 94 · click to enlarge
Page 94

3 EXPANSIONE WIRING code GL-0042-AA

Connectors position in EXPANSION wiring loom code GL-0042-AA. This wiring loom has to be connected to EXP1 (M40 datalogger)

Get M40 — 3 EXPANSIONE WIRING code GL-0042-AA diagram (page 94)
Fig. 80 · 3 EXPANSIONE WIRING code GL-0042-AA

ANALOGUE INPUT AD4

EXP1 CONNECTOR

ANALOGUE INPUT AD5

ANALOGUE INPUT AD6

FREQUENCY INPUT IC3

SW1 INPUT

  • CONNECTOR EXP1: you need to connect this to EXP1 connector of M40
  • CONNECTORS AD4…AD6: analogue inputs (example: potentiometer, thermocouples, etc)
  • CONNECTOR IC3: frequency input (example: wheel speed sensors, rpm, etc)
  • CONNECTOR SW1: switch input, button input, IR receiver input (example: map switch, beacon, etc)

1 + 5 VDC (VREF) 2 Input 3 Ground (GND SEN)

AD4; AD5;

AD6

1 +12 VDC (VBB1) 2 Input 3 Ground (GND SEN)

IC3; SW1

Connector · Pin number Description · name

Page 95 of the Get M40 user manual — IC4; IC5
Page 95 · click to enlarge
Page 95

4 EXPANSION WIRING code GL-0043-AA

Connector position in EXPANSION wiring loom code GL-0043-AA. This wiring loom has to be connected to the cable labelled EXP2 (M40 datalogger)

Get M40 — 4 EXPANSION WIRING code GL-0043-AA diagram (page 95)
Fig. 81 · 4 EXPANSION WIRING code GL-0043-AA

ANALOGUE INPUT AD7

EXP2 CONNECTOR

ANALOGUE INPUT AD8

ANALOGUE INPUT AD9

FREQUENCY INPUT IC4

FREQUENCY INPUT IC5

1 + 5 VDC (VREF) 2 Input 3 Ground (GND SEN)

AD7; AD8;

AD9

  • 1 +12 VDC (VBB1) 2 Input 3 Ground (GND SEN)
  • CONNECTOR EXP2: you need to connect this to EXP2 connector of M40
  • CONNECTORS AD7…AD9: analogue inputs (example: potentiometer, thermocouples, etc)
  • CONNECTORS IC4IC5: frequency input (example: wheel speed sensors, rpm, etc)

IC4; IC5

Connector · Pin number Description · name

Page 96 of the Get M40 user manual — M40 USB CONNECTOR PC USB PORT
Page 96 · click to enlarge
Page 96

5 DATA DOWNLOAD WIRING code GL-0019-AA

DATA DOWNLOADING wiring loom code GL-0019-AA. This wiring loom has to be connected to USB (M40 datalogger)

M40 USB CONNECTOR PC USB PORT

Get M40 — M40 USB CONNECTOR PC USB PORT diagram (page 96)
Fig. 82
Get M40 — M40 USB CONNECTOR PC USB PORT diagram (page 96)
Fig. 83
Get M40 — M40 USB CONNECTOR PC USB PORT diagram (page 96)
Fig. 84

1 USB + USB +5V connection 2 USB P USB N connection 3 USB N USB P connection 4 USB - USB GND connection

1 USB + USB +5V connection 2 USB P USB N connection 3 USB N USB P connection 4 USB - USB GND connection

Page 97 of the Get M40 user manual — WARNING: AVOID SHORTCIRCUITS USING AUXILIARY POWER SUPPLY
Page 97 · click to enlarge
Page 97

6 POWER WIRING code GL-0036-AA

  • This picture shows all connectors of POWER wiring loom code GL-0036-AA . This loom has to be connected to MAIN of M40 . Power wiring loom code GL-0036-AA could power the M40 also with and external power supply (example battery) without the use of the engine. This is interesting especially in vehicles that power the system only with the engine switched on (offroad motorbikes). Interconnection connector to GP1 EVO ECU permit to supply power and log CAN parameters directly from ECU.
  • MAIN M40 CONNECTOR: to be connected to MAIN of M40
  • GP1 EVO CONNECTOR: to be connected to MAIN of GP1 EVO ECU
  • RED WIRING “+”: connect this to positive of auxiliary power supply (if needed)
  • BLACK WIRING “-”: connect this to negative of auxiliary power supply (if needed)

MAIN M40 CONNECTOR

GP1 EVO CONNECTOR

Get M40 — MAIN M40 CONNECTOR diagram (page 97)
Fig. 85

POWER SUPPLY (POSITIVE)

POWER SUPPLY (NEGATIVE)

Get M40 — POWER SUPPLY (POSITIVE) diagram (page 97)
Fig. 86

AUXILIARY

POWER

WARNING: AVOID SHORTCIRCUITS USING AUXILIARY POWER SUPPLY

Page 98 of the Get M40 user manual — ALIMENTAZIONE
Page 98 · click to enlarge
Page 98

7 POWER WIRING code GL-0037-AA

  • The following picture shows all connectors of POWER wiring loom code GL-0037-AA . This cable has to be connected to MAIN of M40 . Power cable code GL-0037-AA could power the M40 also with the battery code DA00010000 without the use of the engine. This is interesting especially in vehicles that power the system only with the engine switched on (offroad motorbikes). Interconnection connector to GP1 EVO ECU permit to power and log CAN parameters from ECU.
  • MAIN M40 CONNECTOR: to be connected to MAIN of M40
  • GP1 EVO CONNECTOR: to be connected to MAIN of GP1 EVO ECU
  • BATTERY CONNECTOR: Binder 4 pins to be connected to battery, code DA00010000 (if needed)

MAIN M40 CONNECTOR

GP1 EVO CONNECTOR

Get M40 — MAIN M40 CONNECTOR diagram (page 98)
Fig. 87

BATTERY CONNECTOR CODE DA00010000

Pin Desription 1 Power (+) (VBAT) 2 Power (+) (VBAT) 3 Power (-) (GND) 4 Power (-) (GND)

ALIMENTAZIONE

AUSILIARIA

Page 99 of the Get M40 user manual — WARNING: AVOID SHORTCIRCUITS USING AUXILIARY POWER SUPPLY
Page 99 · click to enlarge
Page 99

8 POWER – DATA WIRING code GL-0038-AA

  • This picture shows all connectors of POWER-DATA code GL-0038-AA . This loom has to be connected to MAIN of M40 . This loom could power M40 with an external battery and could connect M40 to CAN bus.
  • MAIN M40 CONNECTOR: to be connected to MAIN of M40
  • BATTERY LESS SWITCH: this switch is a cable that connect EN-BLES to the ground: the datalogger switch on is delayed about 10 seconds in order to get the system ready (offroad motorbikes). A wrong power of the devices could cause a malfunctioning of the system. If you do not need the delay, cut the cable.
  • BLUE WIRE “CAN L”: connect to the cable “CAN L” of vehicle CAN bus
  • WHITE WIRE “CAN H”: connect to the cable “CAN H” of vehicle CAN bus
  • RED WIRE “+”: connect to the positive of auxiliary power supply
  • BLACK WIRE “-”: connect to the negative of auxiliary power supply

MAIN M40 CONNECTOR

BLUE WIRE - CAN

BATTERY LESS SWITCH WHITE WIRE - CAN H

Get M40 — MAIN M40 CONNECTOR diagram (page 99)
Fig. 88

POWER SUPPLY (POSITIVE)

+

POWER SUPPLY (NEGATIVE)

ALIMENTAZIONE

AUSILIARIA

WARNING: AVOID SHORTCIRCUITS USING AUXILIARY POWER SUPPLY

Page 100 of the Get M40 user manual — CONNECTOR FOR BATTERY
Page 100 · click to enlarge
Page 100

9 POWER – DATA WIRING code GL-0039-AA

This picture shows all connectors of POWER-DATA code GL-0039-AA. This wiring loom has to be connected to MAIN of M40. This cable could power M40 also with battery code DA00010000 avoiding the connection of the device with vehicle power loom. There are also two wires to connect the vehicle CAN line.

MAIN M40 CONNECTOR

BLUE WIRE - CAN

BATTERY LESS SWITCH

WHITE WIRE - CAN H

Get M40 — MAIN M40 CONNECTOR diagram (page 100)
Fig. 89

CONNECTOR FOR BATTERY

COD. DA00010000

  • MAIN M40 CONNECTOR: to be connected to MAIN of M40
  • BATTERY LESS SWITCH: this switch is a cable that connect EN-BLES to the ground: the datalogger switch on is delayed about 10 seconds in order to get the system ready (offroad motorbikes). A wrong power of the devices could cause a malfunctioning of the system. If you do not need the delay, cut the cable.
  • BLUE WIRE “CAN L”: connect to the cable “CAN L” of vehicle CAN bus
  • WHITE WIRE “CAN H”: connect to the cable “CAN H” of vehicle CAN bus
  • BATTERY CONNECTOR: Binder 4 pins to be connected to battery, code DA00010000 (if needed)

Pin Description 1 Power (+) (VBAT) 2 Power (+) (VBAT) 3 Power (-) (GND) 4 Power (-) (GND)

Page 101 of the Get M40 user manual — MAIN
Page 101 · click to enlarge
Page 101
APPENDIX 4M40 CONNECTION DIAGRAMS Some examples of M40 connections are showed in follows chapters:

1 GP1 EVO - M40 (BATTERY LESS CONFIGURATION)

  • PLEASE NOTE:
  • If CONF. 1 is used, the M40 is powered from GP1EVO
  • If CONF. 2 or CONF. 3 are used, the M40 is powered separately without the need of the bike running
Get M40 — 1 GP1 EVO - M40 (BATTERY LESS CONFIGURATION) diagram (page 101)
Fig. 90

Configuration Parts needed Code: Description CONF.1 – CONF.2 - CONF 3 GL-0018-AA Multilink Cable CONF.1 – CONF.2 - CONF 3 - Datalogger M40 with GPS antenna CONF.1 – CONF.2 - CONF 3 - GP1EVO (ECU) CONF.2 GL-0036-AA Power cable CONF 3 GL-0037-AA Power cable CONF 3 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

CONF. 3

Get M40 — CONF. 3 diagram (page 101)
Fig. 91

EXP

Get M40 — EXP diagram (page 101)
Fig. 92

GP-LC1 MAIN

Get M40 — GP-LC1 MAIN diagram (page 101)
Fig. 93
Get M40 — GP-LC1 MAIN diagram (page 101)
Fig. 94

MAIN

MAIN

Page 102 of the Get M40 user manual — EXP
Page 102 · click to enlarge
Page 102

2 GP1 EVO - LC1 EVO - M40

  • PLEASE NOTE:
  • If CONF. 1 is used, the M40 is powered from GP1EVO
  • If CONF. 2 or CONF. 3 are used, the M40 is powered separately without the need of the bike running

Configuration Parts needed Code: Description CONF.1 – CONF.2 - CONF 3 GL-0018-AA Multilink Cable CONF.1 – CONF.2 - CONF 3 - Datalogger M40 with GPS antenna CONF.1 – CONF.2 - CONF 3 - GP1EVO (ECU) CONF.1 – CONF.2 - CONF 3 - LC1 EVO module (with Lambda sens. and looms) CONF.1 – CONF.2 - CONF 3 GL-0016-AA BASIC Cable (use instead of cod. GL-0017AA) CONF.1 – CONF.2 - CONF 3 GL-0077-AA BASIC Cable (use instead of cod. GL-0016AA) CONF.2 GL-0036-AA Power cable CONF 3 GL-0037-AA Power cable CONF 3 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

Get M40 — 2 GP1 EVO - LC1 EVO - M40 diagram (page 102)
Fig. 95
Get M40 — 2 GP1 EVO - LC1 EVO - M40 diagram (page 102)
Fig. 96

AUX POWER

LC1 EVO MODULE

AN

Get M40 — AUX POWER diagram (page 102)
Fig. 97

AN

BASIC CABLE cod. GL-0016AA

CONF. 3

or cod. GL-0017AA

Get M40 — CONF. 3 diagram (page 102)
Fig. 98

EXP

EXP

GP-LC1 MAIN

MAIN

MAIN

Page 103 of the Get M40 user manual — EXP1
Page 103 · click to enlarge
Page 103

3 LC1 EVO - M40 (ANALOG CONNECTION)

  • NOTE:
  • LC1 EVO module have to be powered separately
  • M40 have to be powered separately
  • After connecting LC1 module to M40, user have to set the channel in datalogger setup

Configuration Parts needed Code: Description CONF.1 – CONF.2 - Datalogger M40 with GPS antenna CONF.1 – CONF.2 - LC1 EVO module (with Lambda sens. and looms) CONF.1 – CONF.2 GL-0041-AA EXPANSION Cable (use instead of GL-0042-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0042-AA EXPANSION Cable ( use instead of GL-0041-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0043-AA EXPANSION Cable ( use instead of GL-0041-AA o GL-0042-AA) CONF.1 GL-0038-AA Power cable CONF 2 GL-0039-AA Power cable CONF 2 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

CONF. 2

CONF. 1

Get M40 — CONF. 2 diagram (page 103)
Fig. 99
Get M40 — CONF. 2 diagram (page 103)
Fig. 100
Get M40 — CONF. 2 diagram (page 103)
Fig. 101

MAIN M40

cod. GL-0039-AA

MAIN M40

cod. GL-0038-AA

Get M40 — MAIN M40 diagram (page 103)
Fig. 102
Get M40 — MAIN M40 diagram (page 103)
Fig. 103

LC1 EVO MODULE

AN ..

Get M40 — LC1 EVO MODULE diagram (page 103)
Fig. 104

MAIN

AN

AN ..

EXP

EXP ..

AN ..

EXP1

EXP2

cod. GL-0041-AA

or cod. GL-0042-AA

or cod. GL-0043-AA

EXPANSION cable

Page 104 of the Get M40 user manual — EXP1
Page 104 · click to enlarge
Page 104

4 LC1 EVO - M40 (CAN BUS CONNECTION)

  • PLEASE NOTE:
  • LC1 EVO module have to be powered separately
  • M40 have to be powered separately
  • After connecting LC1 module to M40, user have to set the channel in datalogger setup

Configuration Parts needed Code: Description CONF.1 - Datalogger M40 with GPS antenna CONF.1 - LC1 EVO module (with Lambda sens. and looms) CONF.1 GL-0018-AA Multilink Cable

Get M40 — 4 LC1 EVO - M40 (CAN BUS CONNECTION) diagram (page 104)
Fig. 105

LC1 EVO MODULE

PROG

GP-LC1 MAIN

Get M40 — LC1 EVO MODULE diagram (page 104)
Fig. 106

LOGGER

MAIN

VT1-PC

EXP

cod. GL-0018-AA

EXP1

EXP2

Page 105 of the Get M40 user manual — CONF. 2
Page 105 · click to enlarge
Page 105

5 M40 - ANALOG SENSORS SUPPLIED AT 5VDC

  • PLEASE NOTE:
  • M40 have to be powered separately
  • After connecting sensors to M40, user have to set the channel in datalogger setup
Get M40 — 5 M40 - ANALOG SENSORS SUPPLIED AT 5VDC diagram (page 105)
Fig. 107

Configuration Parts needed Code: Description CONF.1 – CONF.2 - Datalogger M40 completo di antenna GPS CONF.1 – CONF.2 - GET analog sensor CONF.1 – CONF.2 GL-0041-AA EXPANSION Cable (use instead of GL-0042-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0042-AA EXPANSION Cable ( use instead of GL-0041-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0043-AA EXPANSION Cable ( use instead of GL-0041-AA o GL-0042-AA) CONF.1 GL-0038-AA Power cable CONF 2 GL-0039-AA Power cable CONF 2 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

CONF. 2

CONF. 1

Get M40 — CONF. 2 diagram (page 105)
Fig. 108

Potentiometer · Sensor

Page 106 of the Get M40 user manual — IN IC
Page 106 · click to enlarge
Page 106

6 M40 - ANALOG SENSORS SUPPLIED AT 12VDC

  • PLEASE NOTE:
  • M40 have to be powered separately
  • After connecting sensors to M40, user have to set the channel in datalogger setup

Configuration Parts needed Code: Description CONF.1 – CONF.2 - Datalogger M40 completo di antenna GPS CONF.1 – CONF.2 - GET analog sensor CONF.1 – CONF.2 - 12 VDC sensor interface cable CONF.1 – CONF.2 GL-0041-AA EXPANSION Cable (use instead of GL-0042-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0042-AA EXPANSION Cable ( use instead of GL-0041-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0043-AA EXPANSION Cable ( use instead of GL-0041-AA o GL-0042-AA) CONF.1 GL-0038-AA Power cable CONF 2 GL-0039-AA Power cable CONF 2 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

CONF. 2

CONF. 1

MAIN M40

cod. GL-0039-AA

cod. GL-0038-AA

MAIN M40

Get M40 — MAIN M40 diagram (page 106)
Fig. 109
Get M40 — MAIN M40 diagram (page 106)
Fig. 110

AN ..

MAIN

IN SENS

AD MD3

AN ..

Get M40 — MAIN diagram (page 106)
Fig. 111

EXP

EXP ..

AN ..

EXP1

EXP2

cod. GL-0041-AA

or cod. GL-0042-AA

IN IC

IC MD3

or cod. GL-0043-AA

Show 6 more labels / short text on this page
K-Type Thermocouple · Sensor · Magnetostrictive · Potentiometer · Sensor · EXPANSION cable
Page 107 of the Get M40 user manual — CONF. 2
Page 107 · click to enlarge
Page 107

7 M40 - FREQUENCY SENSORS SUPPLIED AT 12VDC

  • PLEASE NOTE:
  • M40 have to be powered by an external battery
  • After connecting sensors to M40, user have to set the channel in datalogger setup
Get M40 — 7 M40 - FREQUENCY SENSORS SUPPLIED AT 12VDC diagram (page 107)
Fig. 112

Configuration Parts needed Code: Description CONF.1 – CONF.2 - Datalogger M40 completo di antenna GPS CONF.1 – CONF.2 - Frequency Sensor CONF.1 – CONF.2 GL-0041-AA EXPANSION Cable (use instead of GL-0042-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0042-AA EXPANSION Cable ( use instead of GL-0041-AA or GL-0043-AA) CONF.1 – CONF.2 GL-0043-AA EXPANSION Cable ( use instead of GL-0041-AA o GL-0042-AA) CONF.1 GL-0038-AA Power cable CONF 2 GL-0039-AA Power cable CONF 2 DA00010000 Battery with binder connector (only if cod. GL-0037-AA is used)

CONF. 2

CONF. 1

Get M40 — CONF. 2 diagram (page 107)
Fig. 113
Get M40 — CONF. 2 diagram (page 107)
Fig. 114
Get M40 — CONF. 2 diagram (page 107)
Fig. 115

or cod. GL-0043-AA

Vehicle RPM · Sensor · Speed Sensor

Page 108 of the Get M40 user manual — 7 POWER WIRING code GL-0037-AA
Page 108 · click to enlarge
Page 108
Page 108 of the Get M40 user manual — 7 POWER WIRING code GL-0037-AA
Page 109 of the Get M40 user manual — NOTES:
Page 109 · click to enlarge
Page 109

NOTES:

Page 110 of the Get M40 user manual — NOTES:
Page 110 · click to enlarge
Page 110

NOTES:

Page 111 of the Get M40 user manual — NOTES:
Page 111 · click to enlarge
Page 111

NOTES:

Page 112 of the Get M40 user manual — 7 POWER WIRING code GL-0037-AA
Page 112 · click to enlarge
Page 112
Get M40 — 7 POWER WIRING code GL-0037-AA diagram (page 112)
Fig. 116 · 7 POWER WIRING code GL-0037-AA

GET Athena · Alonte (VI) · Italy

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
M40CONTROLS AND INDICATORS ................................................................................................. 9 p.3

Ask about the Get M40

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Get M40

Be the first to ask — other owners or our team will answer.

Original document

Get M40 manual PDF

112 pages·2.9 MB·Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…