- DATA MANAGER -p.1DATA ACQUISITIONp.1SOFTWARE USER GUIDEp.1DATA MANAGER – SOFTWAREp.22 THE SOFTWARE COMPONENTS The components of DATA MANAGER are:p.6FINISH LINEp.9LAP BARp.9Y AXISp.9SPLIT TIMEp.9X AXISp.9LINEAR MAPp.9ASSE Xp.9TAB 1: ENGINEp.9CHANNELSp.9TAB 2: SUSPENSIONp.10TAB 3: SPEED ANDp.10ACCELERATIONp.10LAP TABp.12LAP CORRECTLY DISPLAYED IN THE ANALYSIS WINDOWp.12ANALYSIS CURSORp.13REFERENCE CURSORp.13FINISH LINE SPLIT POINTSp.13LAP SELECTION CHECKp.16BOXp.16BEST LAP IN SESSIONp.16SELECTEDp.16COURSEp.16“OK” BUTTONp.16“CREATE NEW TRACK”p.16BUTTONp.16LAPS ADDED TO THE PROJECTp.17LAP CURRENTLY DISPLAYED IN THE ANALYSIS WINDOWp.17PROGRESSIVE N° ANDp.19CHECKBOX VISIBLE FEATUREp.19SCALE FEATUREp.19CHANNEL NAMEp.19CHECKBOXp.19CHANNEL SAMPLING FREQUENCY COLUMNp.19OVER FEATUREp.19COLOUR FEATUREp.19MIN AND MAX COLUMNSp.19COLUMNp.19COLUMN CHANNEL N° COLUMNp.20QUICK SEARCHp.20CH. FILTERSp.21ADD TABp.21TAB NAME:p.21CHANNEL REFERENCE LINES INSERTION WINDOWp.23REFERENCE LINEp.23FILTER COLUMNp.24FILTER BOX OF CHANNELp.24TO FILTERp.24ORIGINAL CHANNELp.25FILTERED CHANNELp.25NEW MATHEMATICAL CHANNEL CREATION WINDOWp.27DECIMAL PLACES OF THE MATH. CHANNELp.28UNIT OF MEAS. OF THE MATH. CHANNELp.28CHANNELp.28OPERATORS OF THEp.28SELECTION OF THE OPERATORS OF THEp.28DESCRIPTION OF THEp.28MATH CHANNELp.28MATH. CHANNELp.28OVERVIEWp.29WINDOWp.29MANUAL ALIGNMENTp.31MANUAL ALIGNMENT BUTTON IN THE CONTEXTp.31MENUp.31ALIGN TO GPSp.32CONTEXT MENUp.32ANALYSIS WINDOW IN MEASURE. MODEp.32POSITIONp.32POSITION CURSORp.33SHOW/HIDE REFERENCEp.34CURSORp.34CHANNEL VALUE ON REFERENCE CURSORp.34REFERENCE CURSOR TIMEp.34CHANNEL VALUEp.34ON POSITIONp.34POSITION CURSOR TIMEp.34
Page 1 of the Get DATA MANAGER-SOFTWARE user manual — - DATA MANAGER -
Page 1 · click to enlarge
Page 1
Get DATA MANAGER-SOFTWARE — - DATA MANAGER - diagram (page 1)
Fig. 1

- DATA MANAGER -

DATA ACQUISITION

SOFTWARE USER GUIDE

Page 2 of the Get DATA MANAGER-SOFTWARE user manual — DATA MANAGER – SOFTWARE
Page 2 · click to enlarge
Page 2

DATA MANAGER – SOFTWARE

Release 0.0.0 2013 GET by Athena Evolution. All rights reserved. The contents of this document, or any part of it, may not be reproduced, transferred, distributed or

memorised in any form whatsoever without the written permission of GET by Athena Evolution s.r.l.

GET reserves the right to modify the content of this manual without prior notice.

Page 3 of the Get DATA MANAGER-SOFTWARE user manual — DATA MANAGER – SOFTWARE
Page 3 · click to enlarge
Page 3
Page 3 of the Get DATA MANAGER-SOFTWARE user manual — DATA MANAGER – SOFTWARE
Page 4 of the Get DATA MANAGER-SOFTWARE user manual — DATA MANAGER – SOFTWARE
Page 4 · click to enlarge
Page 4

3.2.18.1 Creating a new report 49 3.2.18.2 Updating an existing report 50 3.2.18.3 Best split times and ideal lap 50 3.2.18.4 Saving and loading a report 52 3.2.18.5 Exporting data 52 3.2.18.6 Creating a report on the maximum and minimum channel values 52 3.2.19 Print functions 54 3.2.20 Advanced options 56 3.2.20.1 Trimming a session 57 3.2.20.2 Export functions 58 3.2.20.3 Converting an sxr file 58 4 THE DATA MANAGER MAIN WINDOWS 59 5 THE “Download Data” MANAGER 60 5.1 The Data Storage Settings Area 61 5.2 Command area for connected devices 62 5.2.1 Downloading recorded data (manual mode) 62 5.2.2 Erasing the recorded data from data logger 64 5.3 Tools menu 65 5.3.1 “Convert”: the data format converter 65 5.3.2 The software Options 66 5.3.2.1 “Download File” settings 66 5.3.2.2 “COM Options”: disabling the communication serial ports 67 5.3.2.3 “General Options”: set the software language 67 6 THE “Config Datalogger” MANAGER 68 6.1 Menu bar 69 6.1.1 File menu 69 6.1.2 Menù Setup 69 6.1.3 Watch menu 69 6.1.4 Device menu 70 6.2 Horizontal icons bar 71 6.3 Vertical icons bar 72 6.4 Setting up data logger 73 6.5 WATCH 74 6.5.1 Start and stop “WATCH”: real time channel visualization 74 6.5.2 “WATCH” channel calibration 77 6.5.3 Setting channel zero in “WATCH” 78 6.5.4 Setting channel offset in “WATCH” 79 6.5.5 WATCH: Quick search 79 6.5.6 WATCH: Filtro sui canali 79

Page 5 of the Get DATA MANAGER-SOFTWARE user manual — DATA MANAGER – SOFTWARE
Page 5 · click to enlarge
Page 5
  • 1 BEFORE STARTING Please read carefully following chapters before running DATA MANAGER software . DATA MANAGER is available in two different license:
  • Data Manager free: the freeware version of Data Manager (it includes Download Data , Config Datalogger and Mx2 analysis software)
  • Data Manager – WINTAX: the payment version of Data Manager (it includes Download Data , Config Datalogger, Mx2, Magneti Marelli WINTAX 4 analysis software and license hardware key) 1.1 INSTALLING SOFTWARE 1.1.1 System Requirements Hardware:
  • Processor: Intel Pentium IV o AMD 2GHz or higher – 32/64 bit
  • RAM: 1GB (minimum size)
  • Ethernet Card: 10/100 Mbps (or higher)
  • Communication Port: USB 2.0 Software:
  • Operative System: Microsoft Windows © XP (preferred) , Windows © Vista, Windows © 7 1.1.2 Installing software on Microsoft Windows © In order to install WinTAX4 for GET software proceed as follows:
  • Run the installation file called file Install_DM_ < Release Number > .exe (double click on program icon) PLEASE NOTE: Windows © Vista and/or 7 might require the Administrator privileges to start the installation.

<Release Number>

.exe

DON’T TRY TO INSTALL THE FREEWARE VERSION OF DATA MANAGER IF THE PAYMENT LICENSE IS ALREADY INSTALLED. CONTACT US FOR THE UPGRADES OF PAYMENT VERSION OF DATA MANAGER (SEND AN E-MAIL TO: [email protected])

  • Follow the guided procedure to finish the installation. PLEASE NOTE: fit the HASP USB key (the hardware license) in the USB port before start the WINTAX setup.

Install_DM_

Page 6 of the Get DATA MANAGER-SOFTWARE user manual — 2 THE SOFTWARE COMPONENTS The components of DATA MANAGER are:
Page 6 · click to enlarge
Page 6

2 THE SOFTWARE COMPONENTS The components of DATA MANAGER are:

  • Data Manager software: allows the data download and configuration of GET data logger
  • MX2 analysis software: allows the sessions analysis recorded by GET data loggers
  • WinTAX4 analysis software : allows the sessions analysis recorded by GET data loggers (only for

payment license) The icons will be displayed after the end of software installation (see previous chapter).

Page 7 of the Get DATA MANAGER-SOFTWARE user manual — 2 THE SOFTWARE COMPONENTS The components of DATA MANAGER are:
Page 7 · click to enlarge
Page 7

3 DATA MANAGER: THE ANALYSIS SOFTWARE 3.1 WinTAX4 analysis software All of operative procedures and features of WinTAX4 software are available on corresponding help file (find it on software Help menù). THE USB KEY (HARDWARE LICENSE KEY) HAVE TO BE INSERTED BEFORE RUNNING THE ANALYSIS SOFTWARE Click on the software icon to run WinTAX4:

Page 8 of the Get DATA MANAGER-SOFTWARE user manual — 2 THE SOFTWARE COMPONENTS The components of DATA MANAGER are:
Page 8 · click to enlarge
Page 8

3.2 MX2 analysis software MX2 is the software which allows the user to analyse the data collected by the GET devices. The first time the program is started up, a demonstration project is automatically loaded. This is useful in order to become familiar with the main functions available. 3.2.1 Main window The image above shows the areas in the main MX2 window: A: analysis window B: main toolbar C: navigation bar D: overview window E: course window MX2 has two different visualization modes: the position mode (useful for quick navigation through the laps of the session being analysed) and the measurement mode. As the default setting, the software starts up in position mode. To move from one mode to the other quickly, simply double-click on the analysis window or press the spacebar. When MX2 is in measurement mode the channel value table to appear to the right of the analysis window.

Get DATA MANAGER-SOFTWARE — 2 THE SOFTWARE COMPONENTS The components of DATA MANAGER are: diagram (page 8)
Fig. 2 · 2 THE SOFTWARE COMPONENTS The components of DATA MAN…
Page 9 of the Get DATA MANAGER-SOFTWARE user manual — TAB 1: ENGINE
Page 9 · click to enlarge
Page 9

3.2.2 Analysis window The analysis window is the main area of the MX2 software. This window shows the values of the acquired channels in a graph format.

Get DATA MANAGER-SOFTWARE — FINISH LINE diagram (page 9)
Fig. 3

FINISH LINE

LAP BAR

Y AXIS

SPLIT TIME

X AXIS

LINEAR MAP

ASSE X

It is possible to add more channels to be displayed on the main window, or to create tabs onto which to distribute all the channels to be analysed in the most suitable way. In the demonstration project, the “Engine”, “Suspension” and “Speed-Acceleration” tabs are displayed: by clicking on each of these tabs, it is possible to display the graphs of the corresponding channels in the analysis window.

Get DATA MANAGER-SOFTWARE — FINISH LINE diagram (page 9)
Fig. 4

TAB 1: ENGINE

CHANNELS

Page 10 of the Get DATA MANAGER-SOFTWARE user manual — ACCELERATION
Page 10 · click to enlarge
Page 10
Get DATA MANAGER-SOFTWARE — TAB 2: SUSPENSION diagram (page 10)
Fig. 5

TAB 2: SUSPENSION

CHANNELS

Get DATA MANAGER-SOFTWARE — TAB 2: SUSPENSION diagram (page 10)
Fig. 6

TAB 3: SPEED AND

  • If an individual lap is being analysed, each channel is represented with a different colour graph. If this is not the case, and several laps are being analysed at the same time, the graphs are represented with the colours of the corresponding laps. The analysis window is also composed of the following elements:
  • Y axis: this shows the scale and the name of each channel displayed, using the same colour as the graph.
  • X axis: this shows the scale of the time or the distances (according to the settings).
  • Lap bar: this is composed of numbered rectangles, indicating the number of laps available, relative to the selected sessions. The coloured rectangles indicate the part of the session displayed in the analysis window. Each lap added to the analysis window has a rectangle of the same colour on the lap bar.
  • Linear map (can be viewed at the bottom of the analysis window, under the x scale): if segments have been associated with the course of the selected session, the linear map displays the sequence of the segments relative to the area displayed in the analysis window. Each segment is displayed with the corresponding colour and name. The linear map can be activated/deactivated using the “M” button or from the analysis window context menu.
  • Finish lines: these are represented with white numbered vertical lines and are only displayed if they have been inserted in the course in use.
  • Split times: these are represented by white vertical broken lines. They are only displayed if the course in use contains split points and only if they have been enabled in the program options window.

ACCELERATION

CHANNELS

Page 11 of the Get DATA MANAGER-SOFTWARE user manual — TAB 2: SUSPENSION
Page 11 · click to enlarge
Page 11

3.2.3 Main toolbar The main toolbar is situated at the top of the program window and allows the user quick access to the most commonly used software functions.

Get DATA MANAGER-SOFTWARE — TAB 2: SUSPENSION diagram (page 11)
Fig. 7

The toolbar is composed as follows: A: displays the previous lap B: displays the next lap C: sets the manual/automatic alignment mode (useful when comparing several laps) D: selects the X axis display scale E: zoom in analysis window F: zoom out analysis window G: reset zoom on selected lap H: zoom of the selected area or report of the maximum and minimum channel values of the selected area I: sets the lap trajectory comparison mode (trajectory analysis mode) L: enlarges the track loaded in the project M: reduces the track loaded in the project N: resets zoom 1:1 on the course O: ruler tool (useful for performing measurements in the course window) P: options window (useful for configuring the MX2 options) 3.2.4 Navigation bar The default position of the navigation bar is on the left-hand side of the program window.

The navigation bar is composed as follows: A: displays the browser window B: displays the channel window C: displays the report window D: displays the course library E: opens the Gate Setup Manager F: opens the Gate Download Manager

Page 12 of the Get DATA MANAGER-SOFTWARE user manual — LAP TAB
Page 12 · click to enlarge
Page 12

3.2.5 Overview window (overview bar) The default position of the overview window is in the bottom left-hand corner of the window. This area provides an overview of the session used, listing the available laps and displaying the graphs of the channels selected for the whole session.

The part of the lap displayed in the analysis window is marked off by a rectangle with grey edges, while the numerical value indicating the lap selected is highlighted in white. By dragging the rectangle onto the overview window, the corresponding area is displayed in the analysis window. At the top of the overview window, there is a series of tabs which represent the list of laps selected in the project in use. It is possible to open the laps displayed here quickly, by simply clicking on the corresponding tab. 3.2.6 Course window (Track Bar) The default position of the course window is in the bottom right-hand corner of the program window. In this area, the image of the course associated with the session in use is displayed.

Get DATA MANAGER-SOFTWARE — LAP TAB diagram (page 12)
Fig. 8

LAP TAB

LAP TAB

LAP CORRECTLY DISPLAYED IN THE ANALYSIS WINDOW

Get DATA MANAGER-SOFTWARE — LAP TAB diagram (page 12)
Fig. 9

If more than one lap has been added to the current display, the trajectory of the selected lap is shown in the course window. The part of the lap displayed in the analysis window is shown in the course window with a white line beside the trajectory of the selected lap. This line is only visible when not in trajectory analysis mode (I button on the quick functions bar).

Page 13 of the Get DATA MANAGER-SOFTWARE user manual — ANALYSIS CURSOR
Page 13 · click to enlarge
Page 13

If MX2 is in measurement mode, a circle-shaped indicator with the colour of the lap selected will appear automatically. This indicator is always found in the position corresponding to the position of the analysis window cursor; by moving the cursor therefore, the position indicator will move to the corresponding position on the course. If the reference cursor is activated in the analysis window it is displayed in the course window with a red cross (only if Mx2 is in measurement mode).

Get DATA MANAGER-SOFTWARE — ANALYSIS CURSOR diagram (page 13)
Fig. 10

If the finish line and split points have been added to the track, they will be visible in the Track Bar as grey lines which divide the track.

ANALYSIS CURSOR

REFERENCE CURSOR

FINISH LINE SPLIT POINTS

Page 14 of the Get DATA MANAGER-SOFTWARE user manual — ANALYSIS CURSOR
Page 14 · click to enlarge
Page 14

3.2.7 Creating and managing projects The MX2 software uses project files to manage the set of data and settings used. The session loaded, the channels used and the display and track settings are specified in these files. Through the project files, it is possible to save the program mode in order to recall it later on. This allows the user to ensure that the working environment used at the moment when the project was saved is always available. The demonstration project loaded automatically the first time the MX2 software is run can be closed by clicking on the heading Close project from the File menu. In this way, the program no longer has an active project, therefore the majority of the available options are disabled. At this point, it is possible to create a new project, or alternatively open a project saved previously, by clicking on the headings New project or Open project… present in the File menu.

Get DATA MANAGER-SOFTWARE — ANALYSIS CURSOR diagram (page 14)
Fig. 11

By clicking on New project, the software warns the user that he/she is abandoning the open project (confirm the operation by clicking “YES”), requesting a position and a name for the new project which is being created. After specifying a valid position and name, an empty working space is created into which it is possible to load the sessions and apply the settings required.

Get DATA MANAGER-SOFTWARE — ANALYSIS CURSOR diagram (page 14)
Fig. 12

It is possible to save the state of the project in use at any time by clicking on the heading Save project from the File menu. If it is necessary to specify a different name from the one in use, simply click on the heading Save project as… still from the same menu. In this way, a new position and a new name to give to the file will be requested.

Page 15 of the Get DATA MANAGER-SOFTWARE user manual — ANALYSIS CURSOR
Page 15 · click to enlarge
Page 15

3.2.8 Opening the sessions Once a new project has been created or an existing project opened, it is possible to add laps by selecting the sessions to be used. In order to select a session from those which are available, it is necessary to open the browser bar from the left-hand navigation bar. If the window is opened in the minimised format, expand it by clicking on the arrow positioned in the top right-hand corner of the window itself.

The left-hand side of this window provides a tree structure showing the folders present on the computer hard disk. As a default setting, the sessions are downloaded from the devices into the “Documents\Get” folder of the current Windows user, creating a folder with the name of the device from which the data (MD3, MD4 etc.) is downloaded and a subfolder with the date on which the data was created. On the browser bar, the main folder containing the various sessions is selected automatically, in order to speed up selection operations. Once a folder has been selected from the tree structure, the sessions contained within it are listed in the control just to the right.

Get DATA MANAGER-SOFTWARE — ANALYSIS CURSOR diagram (page 15)
Fig. 13
Get DATA MANAGER-SOFTWARE — ANALYSIS CURSOR diagram (page 15)
Fig. 14
Page 16 of the Get DATA MANAGER-SOFTWARE user manual — SELECTED
Page 16 · click to enlarge
Page 16

When a session is selected, the laps available are listed in the control on the right, while in the bottom left- hand corner, a preview of the course to which the session refers is displayed. In the list of the available laps, the lap number, corresponding time and any notes are present for each heading. The fastest lap of the session is shown in red. PLEASE NOTE: if no course are applied at the session will be display only lap 0

In order to add a lap to the project in use, it is necessary to click on the corresponding checkbox. In this way, the lap is added to the list of laps in the project, in the list present at the bottom of the browser bar. In the same way, in order to delete the lap from the project, it is necessary to click on the checkbox of the lap again in order to erase the tick. Once a lap has been selected, the course selection window will appear: the user is requested to specify which track he/she actually wants to associate with the selected lap. Once the course to be used has been selected, simply click on “OK” in the window. It is also possible to click on “Create new” in the window in order to create a new course (useful if the track is not present in the data library).

Get DATA MANAGER-SOFTWARE — LAP SELECTION CHECK diagram (page 16)
Fig. 15

LAP SELECTION CHECK

BOX

BEST LAP IN SESSION

Get DATA MANAGER-SOFTWARE — LAP SELECTION CHECK diagram (page 16)
Fig. 16

SELECTED

COURSE

“OK” BUTTON

“CREATE NEW TRACK”

BUTTON

Page 17 of the Get DATA MANAGER-SOFTWARE user manual — LAPS ADDED TO THE PROJECT
Page 17 · click to enlarge
Page 17

For each heading, the list containing all the laps added to the project summarises the information regarding the lap itself and the corresponding session, in order to identify all the laps listed with precision and speed.

For each lap added to the project, a tab is also created in the overview window. By clicking on each of these tabs, the corresponding lap will be loaded and the program interface will be updated with the corresponding data.

Get DATA MANAGER-SOFTWARE — LAPS ADDED TO THE PROJECT diagram (page 17)
Fig. 17

LAPS ADDED TO THE PROJECT

LAP TAB

LAP TAB

LAP CURRENTLY DISPLAYED IN THE ANALYSIS WINDOW

Page 18 of the Get DATA MANAGER-SOFTWARE user manual — LAPS ADDED TO THE PROJECT
Page 18 · click to enlarge
Page 18

3.2.9 Displaying the channels After adding laps to the project, it is possible to select the channels to be displayed in the analysis window. In order to do this, it is necessary to open the channels window, by clicking on the corresponding symbol on the left-hand navigation bar. The first time the program is run, the window is opened in the minimised format, and therefore it is necessary to expand it by clicking on the arrow positioned in the top right-hand corner of the window itself.

The channels window is composed of two parts. The top part offers options regarding searching and filtering, the creation of mathematical channels and tab control. These functions will be covered in detail in later paragraphs.

Get DATA MANAGER-SOFTWARE — LAPS ADDED TO THE PROJECT diagram (page 18)
Fig. 18

“Channels Bar” EXPANSION BUTTON

Page 19 of the Get DATA MANAGER-SOFTWARE user manual — CHANNEL SAMPLING FREQUENCY COLUMN
Page 19 · click to enlarge
Page 19

The bottom of the window, on the other hand, offers a list of available channels for the session selected.

Each channel is identified by a progressive number, a name and an icon which refers to the type of channel. The next selection controls, indicated with Visible and Over, enable or disable the display of channel graphs in the analysis window or overview window respectively, while the Scale checkbox displays or hides the scale of channel values along the vertical axis of the analysis window. The next control, Color, allows the user to assign a colour to the channel graph. Simply click on the control and then on the down arrow in order to open the colour palette and choose the colour required. Furthermore, for each channel, it is possible to read the minimum and maximum values (in the Min and Max columns) within the session selected and, in the Hertz column, the frequency at which it was sampled by the instrument.

PROGRESSIVE N° AND

CHECKBOX VISIBLE FEATURE

SCALE FEATURE

CHANNEL NAME

CHECKBOX

Get DATA MANAGER-SOFTWARE — PROGRESSIVE N° AND diagram (page 19)
Fig. 19

CHANNEL SAMPLING FREQUENCY COLUMN

OVER FEATURE

CHECKBOX

COLOUR FEATURE

MIN AND MAX COLUMNS

COLUMN

Page 20 of the Get DATA MANAGER-SOFTWARE user manual — CHANNEL NAME
Page 20 · click to enlarge
Page 20

3.2.9.1 Ordering by name or by number By clicking on the column showing the number or name of the channel, the list is automatically ordered by number or name respectively. As the default setting, the list has ordering by number, nevertheless ordering by name may be useful if many channels are available for the session in use.

3.2.9.2 Quick search The Quick Search control is available in the top left-hand corner of the channels window and allows the user to search quickly through the channels available in the list below. Inserting the name of a channel or part of the name updates the list automatically, leaving only those channels with the specified name visible.

Get DATA MANAGER-SOFTWARE — COLUMN CHANNEL N° COLUMN diagram (page 20)
Fig. 20

CHANNEL NAME

COLUMN CHANNEL N° COLUMN

QUICK SEARCH

Get DATA MANAGER-SOFTWARE — CHANNEL NAME diagram (page 20)
Fig. 21
Page 21 of the Get DATA MANAGER-SOFTWARE user manual — TAB NAME:
Page 21 · click to enlarge
Page 21

3.2.9.3 Channel display filter The controls next to the Quick Search control allow the user to filter the channels based on their type. By selecting one or more headings from those available (Digital, Analog, Sys, Gps, Can, Math), the list is updated automatically, leaving only those channels belonging to the categories specified visible. 3.2.9.4 Creating a new tab The next control, the Add Tab button, allows the user to add a new tab to the analysis window. The creation of a tab may be useful if the user wishes to organise the channels to be displayed into distinct spaces.

CH. FILTERS

Get DATA MANAGER-SOFTWARE — CH. FILTERS diagram (page 21)
Fig. 22

ADD TAB

BUTTON

The demonstration project, for example, has three tabs: Engine, Suspension, Speed-Acceleration, each of which contains the channels relating to it. This division of channels basically allows a tidier and more detailed graphic display. Selecting a tab from the analysis window, in fact, will only display the channels associated with it. By clicking Add Tab, the new tab will be created automatically in the analysis window and the channels window, with the default name New. In order to rename the tab, simply double-click on it (using the left-hand mouse button) in the channels window and specify the new name.

Once the new tab has been added, it is possible to continue assigning the channels, bearing in mind that all the channels selected in the new tab will be visible in the tab with the corresponding name in the analysis window. In order to delete a tab, simply select it from the channels window and press the Del button on the keyboard.

TAB NAME:

Get DATA MANAGER-SOFTWARE — TAB NAME: diagram (page 21)
Fig. 23
Page 22 of the Get DATA MANAGER-SOFTWARE user manual — CH. FILTERS
Page 22 · click to enlarge
Page 22

3.2.10 Operations on the channels This paragraph describes the functions available in the channels window. 3.2.10.1 Lock and Autoscale functions By selecting the Autoscale check box, the software automatically regulates the vertical dimension of the channel graph. As the default option, the autoscale is activated automatically when the channel is set to visible. The Lock function, on the other hand, is used to lock the dimensions and position of the graph (Y axis) on the values set in the Down% and Up% columns. These values can only be set when the channel lock has been performed and specify the vertical limits (as a percentage) of the positions which the graph assumes inside the analysis window. For example, with a lower limit equal to 0% (Down%) and an upper limit equal to 50% (Up%), the graph will be displayed in the bottom half of the analysis window, whereas with a lower limit equal to 50% and an upper limit equal to 100%, the graph will be displayed in the top half of the window. It is also possible to display the graphs in the same area of the analysis window, by giving common values to the Down% and Up% columns. By setting, for example, 0% for all Down% columns and 100% for all Up% columns of the channels, the graphs will take up all the vertical space of the analysis window. Once the display limits have been set, it is important to lock the channel so that its position and dimensions are not reset to the default program values.

Get DATA MANAGER-SOFTWARE — CH. FILTERS diagram (page 22)
Fig. 24
Get DATA MANAGER-SOFTWARE — CH. FILTERS diagram (page 22)
Fig. 25
Page 23 of the Get DATA MANAGER-SOFTWARE user manual — REFERENCE LINE
Page 23 · click to enlarge
Page 23

3.2.10.2 Setting reference values The Ref function, which can be activated by clicking on the boxes in the fourth to last column of the channels window, allows the user to set up to three reference values for each channel.

The reference values allow the user to have horizontal lines on the analysis window, on a level with the assigned values. These lines are mainly used as a reference when studying the channel graphs, like, for example, a lambda probe: it is possible to set the ideal lambda value and compare it to the actual value measured during acquisition.

Get DATA MANAGER-SOFTWARE — CHANNEL REFERENCE LINES INSERTION WINDOW diagram (page 23)
Fig. 26

COLUMN

CHANNEL REFERENCE LINES INSERTION WINDOW

Get DATA MANAGER-SOFTWARE — COLUMN diagram (page 23)
Fig. 27
Get DATA MANAGER-SOFTWARE — COLUMN diagram (page 23)
Fig. 28

REFERENCE LINE

Ref FUNCTION

Page 24 of the Get DATA MANAGER-SOFTWARE user manual — FILTER COLUMN
Page 24 · click to enlarge
Page 24

3.2.10.3 Applying a filter The Filter function (third to last column in the channels window) allows the user to apply a filter to the channel under exam in order to aid reading in the event of disturbances to the acquired signal, for example. In order to enter the filter application window, left-click once on the box in the Filter column relative to the channel to filter.

Get DATA MANAGER-SOFTWARE — FILTER COLUMN diagram (page 24)
Fig. 29

FILTER COLUMN

FILTER BOX OF CHANNEL

TO FILTER

Get DATA MANAGER-SOFTWARE — FILTER COLUMN diagram (page 24)
Fig. 30

In order to apply a filter, it is first necessary to enable it by clicking the Enable filter checkbox in the settings window which is opened.

It is then possible to use the regulation bar below to indicate the percentage of filter application. Clicking on Advanced displays the advanced settings. From these options, it is possible to set the type of filter to be used and the corresponding cutting frequency.

Get DATA MANAGER-SOFTWARE — FILTER COLUMN diagram (page 24)
Fig. 31
Get DATA MANAGER-SOFTWARE — FILTER COLUMN diagram (page 24)
Fig. 32
Page 25 of the Get DATA MANAGER-SOFTWARE user manual — ORIGINAL CHANNEL
Page 25 · click to enlarge
Page 25

Once the OK button has been pressed, a channel with the name of the original channel is created and the ending _f is added. The new channel will be visible in the analysis window if the original channel was visible. If this was not the case, it must be selected manually.

3.2.10.4 Calibration The calibration of a channel is an essential operation to convert the signals, collected by the sensors, into data understandable to the user. The Calibration screen opens by clicking on the desired channel’s Calibrate button with the left button of the mouse button (see figure below).

ORIGINAL CHANNEL

FILTERED CHANNEL

Get DATA MANAGER-SOFTWARE — ORIGINAL CHANNEL diagram (page 25)
Fig. 33
Get DATA MANAGER-SOFTWARE — ORIGINAL CHANNEL diagram (page 25)
Fig. 34
Page 26 of the Get DATA MANAGER-SOFTWARE user manual — ORIGINAL CHANNEL
Page 26 · click to enlarge
Page 26
  • Calibration Type: allows you to choose the type of calibration to use in the channel selected: A list of types of calibration appears when you click on the button with the left button of the mouse button. Make the choice based on the type of channel you are working on: e.g. for potentiometer sensors choose Linear . Refer also to datalogger and/or sensor user manuals to find the proper channel calibration
  • Fields X, Y : Allows the association of the values read by the sensors (in the fields marked with X ) to values set by the user (in the fields marked with Y ). This combination of values defines that calibration of the channel. By clicking on an X field and then clicking the Capture button on the top right corner of the Calibration dialog box, the current value of the channel ( Y field) is associated to the previously selected X field. WARNING: The direct acquisition procedure described above must be made with the GET data acquisition connected to a PC. If there is no data acquisition device connected to a computer you can enter the values in the X and Y fields manually using the keyboard. NOTE: consult the instruction booklet of the sensor being calibrated to know the XY values to enter in the appropriate fields
  • The Show in volts option, if enabled, shows the voltage of the channel expressed in volts. 3.2.10.5 Applying an offset You can use the offset the button to specify a value to be added or subtracted to the value read from the selected channel. Use positive values to subtract the offset from the channel and negative values to add offset, confirm the data entered with the OK button. 3.2.10.6 Mathematical channels A mathematical channel is a channel which is obtained by applying the appropriate mathematical functions to one or more of the previously acquired channels. It is possible, for example, to create the “acceleration” mathematical channel, using the speed derivative.
Get DATA MANAGER-SOFTWARE — ORIGINAL CHANNEL diagram (page 26)
Fig. 35
Page 27 of the Get DATA MANAGER-SOFTWARE user manual — NEW MATHEMATICAL CHANNEL CREATION WINDOW
Page 27 · click to enlarge
Page 27

3.2.11 Creating a mathematical channel Clicking on the Add math button located at the top of the channels window displays the window for the creation of a new mathematical channel. From this window, it is possible to set the name to be given to the new channel, its unit of measurement, the precision which is to be obtained (number of decimal places) and the formula to be used. In particular, in order to write the formula of the mathematical channel, it is possible to use the quick links in the list present in the bottom left-hand corner of the window. Once the object has been specified (Channel, Constant, Function, Operator), the list is automatically updated with the available elements. By clicking on one of these elements, a short description of the element selected is displayed in the checkbox to the right.

Get DATA MANAGER-SOFTWARE — NEW MATHEMATICAL CHANNEL CREATION WINDOW diagram (page 27)
Fig. 36

BUTTON

Get DATA MANAGER-SOFTWARE — BUTTON diagram (page 27)
Fig. 37

NEW MATHEMATICAL CHANNEL CREATION WINDOW

“Add math”

Page 28 of the Get DATA MANAGER-SOFTWARE user manual — OPERATORS OF THE
Page 28 · click to enlarge
Page 28

Double-clicking on one of the elements in the list, on the other hand, updates the formula box, inserting the element selected at the end. Finally, on clicking on OK, the newly-created mathematical channel is added to the list in the channels window. 3.2.11.1 Modifying and deleting a mathematical channel By double-clicking on the mathematical channels created with the method referred to previously, the mathematical channel creation window is opened from which it is possible to modify the setting for the channel selected. Once the necessary changes have been made, click on OK to save them and return to the channel window. In order to delete a mathematical channel, simply select it from the channels window and press Del on the keyboard.

DECIMAL PLACES OF THE MATH. CHANNEL

UNIT OF MEAS. OF THE MATH. CHANNEL

NAME OF THE MATH.

CHANNEL

Get DATA MANAGER-SOFTWARE — CHANNEL diagram (page 28)
Fig. 38

OPERATORS OF THE

SELECTION OF THE OPERATORS OF THE

DESCRIPTION OF THE

OPERATORS OF THE

MATH CHANNEL

MATH. CHANNEL

MATH. CHANNEL

Page 29 of the Get DATA MANAGER-SOFTWARE user manual — LAP BAR
Page 29 · click to enlarge
Page 29

3.2.12 Visualization modes From the analysis window, it is possible to set two different visualization modes: the position mode (useful for quick navigation through the laps of the session being analysed) and the measurement mode. As the default setting, the software starts up in position mode. To move from one mode to the other quickly, simply double- click on the analysis window or press the spacebar. 3.2.12.1 Position mode The position mode is used as the default mode when the MX2 software is run and allows the user to choose which of the graph areas to analyse quickly. There are three different methods for moving the graphs inside the analysis window:

  • by moving the selection square in the overview window, displaying the graphs of the channels in the corresponding interval. Note that, when using this method, the current lap (shown in the tab of overview window) is also changed if the selection square of the overview bar is moved onto a different lap.
  • by moving the coloured lap rectangles in the lap bar, located above the analysis window. Also in this case, the graphs of the channels are displayed in the corresponding intervals, and the current lap (shown in the tab of overview window) is also changed if the rectangle is moved onto a different lap.
  • by clicking on the analysis window and dragging the mouse to the right or to the left, the graphs scroll to the side. In this case, the current lap (shown in the tab of overview window) is not change if the graphs are dragged onto a different lap.

LAP BAR

OVERVIEW

WINDOW

Page 30 of the Get DATA MANAGER-SOFTWARE user manual — OVERVIEW
Page 30 · click to enlarge
Page 30

3.2.12.2 Measurement mode The measurement mode is used to carry out measurement on the graphs which are displayed. This mode can be activated with a double-click on the analysis window or by pressing the spacebar on the keyboard. The measurement mode causes the channel value table to appear to the right of the analysis window.

Get DATA MANAGER-SOFTWARE — OVERVIEW diagram (page 30)
Fig. 39
Page 31 of the Get DATA MANAGER-SOFTWARE user manual — MANUAL ALIGNMENT
Page 31 · click to enlarge
Page 31

3.2.13 Manual alignment If more that one lap has been added to the project, it is possible to move an individual lap in order to align it with the others as required. In order to do this, it is necessary to use manual alignment, which can be activated from the third button on the navigation bar or with the corresponding heading from the context menu which can be displayed with a right-click on the analysis window. This mode is only available in the position mode of the analysis window. Once manual alignment has been activated, it is possible to move the graphs of the lap selected by simply clicking on the analysis window and dragging the mouse horizontally. After aligning the lap, click once more on the navigation bar button or on the heading on the context menu of the analysis window (which can be activated with a right-click above the channel graphs area) to exit manual alignment mode.

Get DATA MANAGER-SOFTWARE — MANUAL ALIGNMENT diagram (page 31)
Fig. 40

MANUAL ALIGNMENT

BUTTON

MANUAL ALIGNMENT BUTTON IN THE CONTEXT

MENU

Get DATA MANAGER-SOFTWARE — MANUAL ALIGNMENT diagram (page 31)
Fig. 41
Page 32 of the Get DATA MANAGER-SOFTWARE user manual — ALIGN TO GPS
Page 32 · click to enlarge
Page 32

3.2.14 Alignment to a GPS point Alignment to a GPS point allows the user to align all the open laps in the project to a GPS point indicated on the selected lap. In order to choose the GPS point to use for alignment, it is first necessary to enter measuring mode (by double-clicking on the analysis window or by pressing the spacebar on the keyboard). When the cursor is displayed on the window, move it to the required point, then open the context menu of the analysis window (by right-clicking in the channel graph area) and select the heading Align to GPS position. In this way, all the laps will be aligned to the GPS point indicated by the cursor. 3.2.14.1 Resetting the alignments The last heading in the context menu of the analysis window, Reset alignments, allows the user to erase all the alignments introduced previously, in order to reset each graph to its original position.

ALIGN TO GPS

CONTEXT MENU

ANALYSIS WINDOW IN MEASURE. MODE

POSITION

Get DATA MANAGER-SOFTWARE — ALIGN TO GPS diagram (page 32)
Fig. 42
Page 33 of the Get DATA MANAGER-SOFTWARE user manual — POSITION CURSOR
Page 33 · click to enlarge
Page 33
  • 3.2.15 Positioning and moving the cursor Having entered the measurement mode, a white vertical cursor appears automatically, indicating the position on which the measurements are being carried out. In order to move the cursor along the acquisition, it is possible to use the following methods:
  • Click on any point of the graphs.
  • Click on any point of the graphs and hold down the left-hand mouse button to drag the cursor to the left and to the right.
  • Use the left and right arrows on the keyboard.
  • Hold down CTRL and use the left and right arrows on the keyboard to move the cursor more quickly. 3.2.15.1 Cursor values (values table) Entering in measurement mode, a table displaying the values of the graphs in the intersection position with the cursor appears on the right-hand side of the screen.

POSITION CURSOR

Get DATA MANAGER-SOFTWARE — POSITION CURSOR diagram (page 33)
Fig. 43

The first elements displayed indicate the value of the X axis (time and distance) which is being referred to for reading the values of the channels represented in the graphs. Under this, the boxes with the names and values of the channels are displayed, each with its own colour (in order to set the channel colour, see chapter 3.2.9 of this manual) and with the value assumed at the point where the position cursor is situated.

Page 34 of the Get DATA MANAGER-SOFTWARE user manual — REFERENCE
Page 34 · click to enlarge
Page 34
  • If more than one lap is being compared the channels will be grouped by name and will be displayed with the colour of the lap to which they correspond. The channel which is being measured is indicated with a box with a white background: it is possible to move observation between the channels in use using the up and down arrows on the keyboard, or by left-clicking the value of the channel to be chosen. In order to resize the values table, position the mouse pointer on the left-hand edge of the table, click using the left-hand mouse button and drag it to the left or to the right (according to the dimensions required). 3.2.15.2 Reference cursor The reference cursor is an additional cursor which is used as a reference for displaying the data between two cursors. The reference cursor is represented by a red vertical line and can be activated in three different ways:
  • By pressing the shift key on the keyboard and by clicking on any point of the analysis window .
  • Pressing R on the keyboard, the reference cursor appears in the position of the mouse pointer. Pressing R on the keyboard again hides the reference cursor.
  • By selecting the heading show/hide second cursor from the context menu in the analysis window. Repeating the operation hides the reference cursor. In order to move the reference cursor, all the methods mentioned for moving the main cursor are valid, but in addition it is necessary to hold down the shift button on the keyboard.

After activating the reference cursor, an additional bar appears at the top of the analysis window. This bar shows the data regarding time, distance, values of the channel selected in the values table and difference (delta) between the two cursors.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 34)
Fig. 44

REFERENCE CURSOR

POSITION CURSOR

SHOW/HIDE REFERENCE

CURSOR

SELECTED

POSITION

CHANNEL VALUE ON REFERENCE CURSOR

CURSOR

REFERENCE CURSOR TIME

CHANNEL VALUE

ON POSITION

Get DATA MANAGER-SOFTWARE — REFERENCE CURSOR diagram (page 34)
Fig. 45

CHANNEL

POSITION CURSOR TIME

VALUES

DISTANCE DIFF.

REFERENCE

CURSOR TIME

Page 35 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 35 · click to enlarge
Page 35

3.2.16 Display options This chapter describes the MX2 software display options. 3.2.16.1 Moving between session laps Once the lap has been selected in the browser bar, it is added to the project. It is possible to move between the laps of the corresponding session by simply using the left and right arrows on the toolbar.

It should be noted that, after changing the active lap, the indicator of the laps added to the project, located on the overview bar, is updated automatically. 3.2.16.2 Selecting the loaded laps A tab for each lap added to the project is present at the top of the overview window. Selecting a tab from this window changes the active lap and the analysis window is updated automatically in order to display the corresponding data.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 35)
Fig. 46
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 35)
Fig. 47
Page 36 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 36 · click to enlarge
Page 36
  • 3.2.16.3 Comparing the laps If more than one lap is added to the project, the analysis window superimposes the graphs of different laps, dividing them by channel. In this way, it is possible to analyse the values of the channels belonging to different laps instant by instant. Use the alignment options described in the previous paragraph to move the individual graphs to the desired position, then use the measurement mode to read the values of the channels in the position indicated by the cursor. 3.2.16.4 Zoom on the analysis window One of the options offered by the MX2 software is that of performing a zoom on the analysis window, in order to enlarge a particular portion of the window or make a wider interval of time or space visible. There are different methods for performing a zoom:
  • Using the zoom in and zoom out buttons present on the toolbar ( )
  • Using the mouse scrolling function
  • With the + and – keys on the numerical keypad on the keyboard
  • Using the Z key on the keyboard to zoom-in and the A key on the keyboard to reset the zoom on the current lap. The zoom on the current lap can also be reset using the designated button on the toolbar.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 36)
Fig. 48

In measurement mode, the zoom is performed at the position of the cursor, so that it is always positioned in the centre of the analysis window. In position mode, on the other hand, the zoom is performed using the part of the analysis window displayed as reference. It is possible to zoom in on a specific area of the analysis window, by clicking on the corresponding button on the toolbar, then clicking on the graph and dragging the mouse horizontally, in order to draw the selection rectangle for the zoom.

Page 37 of the Get DATA MANAGER-SOFTWARE user manual — GRAPH MANAGEMENT
Page 37 · click to enlarge
Page 37

When the mouse button is released, a context menu appears from which it is possible to choose the heading Zoom, which allows the selected area to be enlarged, or choose the heading MaxMin, which generates a window with the maximum and minimum values of all the channels in the selected area. 3.2.16.5 Setting the X axis It is possible to set the X axis of the analysis window in time or position mode. In the first case, the unit of measurement will be seconds, while in the second case the unit of measurement will be metres. To set the X axis, select the Graph management button on the toolbar, choose the option required then press OK to make the changes required.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 37)
Fig. 49

AREA ZOOM BUTTON

CONTEXT MENU

Get DATA MANAGER-SOFTWARE — AREA ZOOM BUTTON diagram (page 37)
Fig. 50

GRAPH MANAGEMENT

BUTTON

X AXIS UNIT OF MEASURE. SELECTION

Page 38 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 38 · click to enlarge
Page 38

3.2.16.6 Locking the visualization scale between tabs In the analysis window, the use of the zoom functions on the graphs has no effect on the zoom of the graphs present in different tabs from the one selected. It is nevertheless possible to connect the zoom of all the tabs present in the analysis window, so that the same level of zoom is applied to all the tabs. In order to do this, it is necessary to activate the Lock visualization scale between tabs option, present on the View menu. To restore the default setting, click on the heading again in order to erase the tick.

3.2.16.7 Changing the visualization settings In order to access the visualization settings control window, click on the designated button on the toolbar or click on the heading Settings… from the Options menu.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 38)
Fig. 51
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 38)
Fig. 52
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 38)
Fig. 53
Page 39 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 39 · click to enlarge
Page 39
  • There are 2 tabs in the dialog window which appears: the first, Analysis options , allows the user to set the following controls:
  • Show horizontal cursor: to display a horizontal line at the point of intersection between the cursors and the graphs in the analysis window.
  • Show cursor info: to display a numerical box which shows the value (relative to the position of the cursor) of the channel selected, when measurement mode is active.
  • Show lap times: to display the time of each lap along the finish lines.
  • Show lap times in the overview: to display the time of each lap in the overview window.
  • Show split times: to display the vertical broken lines in the analysis window which identify the position of split times.
  • Unlock overview bar: allows the user to modify the position and dimensions of the overview window.
  • Unlock track bar: allows the user to modify the position and dimensions of the track window. The second tab, Colours and characters , allows the user to set the colour and characters used by the MX2 software.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 39)
Fig. 54

3.2.16.8 Course window The default position of the course window is in the bottom right-hand corner of the program window. In this area, the image of the course associated with the session in use is displayed. By pressing the button on the main toolbar, it is possible to enter trajectory analysis mode. This function allows the user to compare the trajectories of laps selected on the Browser Bar inside the course window (Track Bar): if only one lap has been selected, a single line will be displayed.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 39)
Fig. 55
Page 40 of the Get DATA MANAGER-SOFTWARE user manual — LAP 2 TRAJECTORY
Page 40 · click to enlarge
Page 40

When the function is not activated, all the trajectories of the loaded session are superimposed on each other. In order to display the difference between the laps correctly, it may be necessary to zoom in on the course window.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 40)
Fig. 56

TRACK BAR

WITH TRAJECTORY COMPARISON

BETWEEN 2

LAPS

3.2.16.9 Zoom on the course window In order to display an enlargement of a specific part of the course, it is possible to enter in measurement mode (see point 6.7.2) and position the cursor near the point of the course which is to be zoomed in on. It is then possible to use the Zoom in and Zoom out buttons on the main toolbar to enlarge or reduce the display of the track inside the window.

These zoom functions are particularly advisable during visualization in trajectory analysis mode, when it is necessary to identify the differences between the trajectories of the laps added to the project.

Get DATA MANAGER-SOFTWARE — TRACK BAR diagram (page 40)
Fig. 57

LAP 2 TRAJECTORY

LAP 1 TRAJECTORY

Page 41 of the Get DATA MANAGER-SOFTWARE user manual — RULER TOOL BUTTON
Page 41 · click to enlarge
Page 41

3.2.16.10 Ruler tool The ruler tool, which can be activated by pressing the second to last button on the main toolbar, allows the user to measure the distance between two points inside the course window. In order to use this tool, click on the course window button to set an point from which to start measurement then hold down the left-hand mouse button, drag the pointer to the final point and release the button. This operation produces a white segment with the indication of the distances between its 2 ends in metres.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 41)
Fig. 58

RULER TOOL BUTTON

POINT TO POINT MEASUREMENT IN

METRES

Page 42 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 42 · click to enlarge
Page 42

3.2.17 Track library The track library contains the list of all the courses available. When it is accessed the user can operate on these courses, setting the finish lines and the points where the split times are measured, dividing the path into segments and selecting the course to apply to the session in use. In order to display the Track Library Management window, simply click on the corresponding button on the left-hand navigation bar. The left-hand side of the Track Library Management window shows a graphic representation of the course, with the finish line, split points and segments (if set). See the following paragraphs for further information about these elements. On the right-hand side of the window, on the other hand, there is a list of the courses available and the buttons which allow the user to perform some simple operations on them, for example, copy, create and delete. These operations are also discussed in more detail in the following paragraphs. 3.2.17.1 Selecting the courses Select the course required by left-clicking on the relative name (search through the Tracks Present list). The course is selected and the corresponding image is displayed automatically on the left-hand side of the window. Once a course has been selected, it is possible to operate on it and save any changes made, without necessarily having to apply the course to the sessions in use. 3.2.17.2 Applying the course to the loaded sessions After loading one or more session into the project, it may be necessary to change the track assigned by default, in order to use a course with a different layout of the finish line and the points where split times are measured, for example. In order to assign a new course to the session in use, it is necessary to select it from the track list, then press Apply to apply the choice made, Once the window has been closed with the Close button, all the open sessions will use the new course.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 42)
Fig. 59
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 42)
Fig. 60
Page 43 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 43 · click to enlarge
Page 43

3.2.17.3 Creating, deleting and copying the courses Using the track library, it is possible to perform some simple operations on the courses in the list. If the user wishes to modify the course in use without losing the original settings, for example, it is possible to create a new version of the course by pressing the Create New button. In this way, a new track with the name new_track will be created in the Tracks Present list. This track will be a version with no finish line, split points or segments of the course in use. If, on the other hand, the user wishes to make a copy of an existing track, simply select and press the Create Copy… button. The user will be required to specify a name for the new track. Finally, in order to delete a track, simply select it and press the Delete button. The track will be deleted from the track list and will be erased from the computer hard drive.

3.2.17.4 Setting the finish line As a session may be divided into laps, it is necessary for the associated track to have a finish line, In order to set a finish line on a previously selected track, click on the first control at the top of the track library. From this control, it is possible to select which element to add or modify in the graphic representation of the course below.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 43)
Fig. 61

Once the heading Finish line has been selected (in the drop-down control in the top left-hand corner), it is possible to define the corresponding position on the course (FL) by clicking on the image of the track and dragging the mouse (holding down the left-hand button), drawing a line with the required dimensions. When the mouse button is released, the finish line is positioned permanently. Ensure that the finish line intersects the course, otherwise the laps cannot be calculated. It is advisable to create a stretch which is perpendicular to the direction of travel and has a suitable length, neither too short (otherwise it does not divide all the laps), nor too long (otherwise it may intersect the lap at several points). If, on the other hand, the finish line is

Page 44 of the Get DATA MANAGER-SOFTWARE user manual — ERASER BUTTON
Page 44 · click to enlarge
Page 44

already positioned and the user wishes to change its position slightly, position the mouse pointer on the corresponding dash and drag the ends until reaching the desired position.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 44)
Fig. 62

COURSE ZOOM BUTTONS

FINISH LINE (FL)

In order to delete the finish line, ensure that the heading Finish Line is selected in the drop-down control in the top left-hand corner then press the Eraser button.

Get DATA MANAGER-SOFTWARE — COURSE ZOOM BUTTONS diagram (page 44)
Fig. 63

ERASER BUTTON

FINISH LINE ERASED

Page 45 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 45 · click to enlarge
Page 45

3.2.17.5 Setting the split points In order to position the lines where the split times are to be taken, select the Split headings from 1 to 4 from the selection control available in the top left-hand corner of the Track Library Management window, then insert the corresponding stretches as shown in the previous paragraph. In order to add the split points, it is necessary to respect the order from 1 to 4, following the direction of travel around the track. It is not necessary to insert all the split points. Ensure that all the split points inserted intersect the course, otherwise the split times will not be calculated correctly. In order to delete a split point, select it in the control in the top left-hand corner, then press the Eraser button (as seen for erasing the Finish Line).

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 45)
Fig. 64
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 45)
Fig. 65
Page 46 of the Get DATA MANAGER-SOFTWARE user manual — OK BUTTON SEGMENT NAME
Page 46 · click to enlarge
Page 46

3.2.17.6 Setting the segments The last heading of the previous selection control, marked Segments, allows the user to define the color sectors which will be displayed in the lower bar of the analysis window. These are used to divide the course into distinct parts, which can be displayed on the linear map on the analysis window and in the reports, dealt with in the next chapter. The segments are positioned in the same way seen before for the finish line and the split points. For the segments, though, it is necessary to specify additional information such as the name and type. After inserting all the stretches which mark the segments, click on the Left curve (usually red) or Right curve buttons (usually green) , then click on the corresponding stretches of track to assign the type. The type/colour selected will be assigned to the stretch of track which is clicked on, then the user will be requested to enter a name to identify the segment. As the default option, the segments are identified with a number whose value is increased from time to time, but it is also possible to specify a personalised name (by left-clicking near the text box with the number on the left of the OK button). Press OK to assign the name to the segment. curva=curve As the default setting, the colour green is used for right curves, the colour red for left curves while the stretches which are not assigned a colour and therefore remain blue identify a straight line. It is important to note that, for correct operation of the reports on the segments, the finish line must be positioned on a blue stretch. In order to delete a segment, click on one of the ends of a stretch which marks it off, then move it out of the line of the course so that it does not intersect it. The segment will be deleted automatically. In order to delete all the segments of the course, ensure that the heading Segments is active in the control in the top left-hand corner, then press the Eraser button.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 46)
Fig. 66

“RIGHT CURVE” AND “LEFT CURVE”

BUTTONS

Get DATA MANAGER-SOFTWARE — “RIGHT CURVE” AND “LEFT CURVE” diagram (page 46)
Fig. 67
Get DATA MANAGER-SOFTWARE — “RIGHT CURVE” AND “LEFT CURVE” diagram (page 46)
Fig. 68

OK BUTTON SEGMENT NAME

BOX

Page 47 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 47 · click to enlarge
Page 47

3.2.17.7 Rotating and zooming in on the selected course In order to insert the finish line and split points precisely, position them on the course, then use the Zoom in button to enlarge the corresponding part of the track.

It is possible to correct the position of the stretch which has just been inserted if an enlargement of the part of the track on which the user is operating is available. Use the Zoom out button to go back to the original dimensions. The course rotation function allows the user to rotate the selected course by between 0 and 360 degrees in order to aid insertion of the finish line, split points and segments.

Last of all, the left and right arrow buttons on the toolbar allow the user to select which lap of the session used to operate on (useful when creating a new track in order to perform the operations described above on the best acquired course). 3.2.17.8 Saving the course When modifying the settings for a course, for example inserting segments or moving the finish line, it is important to press the save button, in order to memorise the new settings. Saving the new course does not imply that the new settings are used in the session in use. In order to apply the changes to the session in use, it is, in fact, necessary to press the Apply button. This double step allows the user to modify several courses, selecting them one at a time from the list on the right, without having to modify the course used by the project sessions.

Page 48 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 48 · click to enlarge
Page 48

3.2.18 Report window The report window allows the user to display a summary of the times achieved in the laps of the loaded sessions. In order to display the report window, simply click on the corresponding button on the left-hand navigation bar. In the top of the window, there is the button which updates a previously created report. In the part immediately below that, on the other hand, the table summarising the times of the loaded session (lap time and the relative split times) is displayed. The report is presented in the form of a table divided into sessions, in which each line represents a lap and each column represents a sector or a segment. CAUTION: the first time the report screen is opened, a table appears showing times relative to the first four laps of the loaded session only (default layout). In order to see the full report of the times, refer to the next chapter in this manual and create a new report using the Lap Time channel.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 48)
Fig. 69
Page 49 of the Get DATA MANAGER-SOFTWARE user manual — CONTROLS
Page 49 · click to enlarge
Page 49
  • 3.2.18.1 Creating a new report In order to create a new report, simply right-click on the Report window and select the heading Report management . The window for creating a new report is then displayed. The controls at the top of the window allow the user to manage the tabs of the report window. As with the analysis window (see chapter 6.4.4 ), in this window it is also possible to divide the elements into different tabs in order to obtain a personalised display of the reports. In order to select the tab on which to create the report, click on the Current Tab selection control and choose the tab required (if present, otherwise it is necessary to create a new one). The buttons immediately to the left, New tab , Delete tab , Rename tab , allow the user to create a new tab, delete a previously created tab or change the name of an existing tab respectively. The bottom of the window, on the other hand, allows the user to configure the report to be created. To configure a report, proceed as follows:
  • Select one of the sessions in the Sessions present area. Here, all the sessions loaded in the analysis window are shown.
  • In order to select the laps, click on one of the headings in the Configure laps box: All : all the laps are selected. Best : the lap with the best time is selected. Choose : selecting this heading activates the window below where it is possible to choose the desired lap.
  • In the Configure segments/sectors box, select one of the headings: Sectors : which represent the split times (SP1, SP2, etc. ). Segments : which represent the stretches which the track has been divided into, using the Segments function which can be accessed from track management (see chapter 6.9.6 ).
  • Select the channel from which the report is to be taken in the Available channels area.
  • In the Functions box, select the type of function to be applied to the report: Min : restores the minimum value present in the chosen channel and in the selected acquisition stretch. Max : restores the maximum value present in the chosen channel and in the selected acquisition stretch. Avg : restores the average value of the selected channel. In : restores the value of the channel at the moment of entry into the selected acquisition stretch. Out : restores the value of the channel at the moment of exit from the selected acquisition stretch Delta : restores the channel difference, typically used for system channels such as:
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 49)
Fig. 70

TAB MANAGE.

CONTROLS

- Lap time - Time, the overall acquisition time. - Lap distance, the length of the lap. - Distance, the length of the whole acquisition. In order to select these elements from the report creation window, double-click on the headings to add. Each heading selected from the report creation window is displayed in bold and will appear on the report window summary. Once the headings required have been chosen, click on OK and wait for the report to be created.

Page 50 of the Get DATA MANAGER-SOFTWARE user manual — FASTEST LAP TIME
Page 50 · click to enlarge
Page 50

3.2.18.2 Updating an existing report Once a report has been created using the procedure described in the previous paragraph, it is possible to update the values table quickly by simply clicking the Update report button, located at the top of the window. Updating an existing report can be useful when, after modifying the settings of the course or the channels, the user wishes to display the new summary, maintaining the same report settings. 3.2.18.3 Best split times and ideal lap Creating a report using the Lap time channel, the report window gives an indication of the best split times for each sector or segment, according to the type of report created. The best split times for the session can be recognised as they are displayed in blue.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 50)
Fig. 71
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 50)
Fig. 72

FASTEST LAP TIME

IN THE SESSION

SLOWEST LAP

TIME IN THE

BEST SPLIT TIMES IN

SESSION

THE SESSION

Page 51 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 51 · click to enlarge
Page 51

If the report is created on more than one session, the best split times referring to the individual session are displayed in light blue while the overall best split times (of all the sessions displayed in the report) are displayed in blue. A further indicator given by the report window is the ideal lap, i.e. the lap which could have been achieved adding together the best split times. The ideal lap is displayed in the top left-hand corner of the report window.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 51)
Fig. 73
Page 52 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 52 · click to enlarge
Page 52

3.2.18.4 Saving and loading a report One of the options offered by the MX2 software is to save the reports created, so that they can be loaded and displayed later on. In order to save a report, simply right-click on the report window and select the heading Save layout… The program will request a position and a name for the file to be saved. In the same way, in order to load a previously saved report, simply select the heading Load layout… from the same context menu, and finally select the corresponding file. 3.2.18.5 Exporting data The data displayed in the report table can be copied so that it can be used with other programs. In order to select the data to copy, click on a cell in the table and, holding down the left-hand mouse button, drag the mouse in order to select the required data interval. Once the mouse button has been released, press Ctrl+C to copy the data to the Microsoft Windows clipboard. The data selected is now available for any software. To display the data using Microsoft Excel, for example, open the program, select a cell and use the Paste function to paste in the data. 3.2.18.6 Creating a report on the maximum and minimum channel values In order to display a report on the maximum and minimum values of the channels displayed in the analysis window in a certain interval, select the corresponding button on the main toolbar (the mouse pointer transforms into a magnifying glass).

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 52)
Fig. 74
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 52)
Fig. 75
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 52)
Fig. 76
Page 53 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 53 · click to enlarge
Page 53

Click on the starting point of the desired interval in the analysis window and then, holding down the left-hand button, drag the mouse to the final point of the interval to use and release the left-hand button. The context menu appears as shown below: Selecting the heading MaxMin creates a report on the maximum, minimum and average values of the channels displayed, relative to the interval selected.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 53)
Fig. 77
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 53)
Fig. 78
Page 54 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 54 · click to enlarge
Page 54

3.2.19 Print functions The MX2 software allows the user to print what is displayed in the analysis window, the track window and the report window at any time. In order to access the print functions, click on the heading File on the main menu. By clicking on the heading Print settings on the context menu which is opened, the settings window is displayed. From this window, it is possible to select the elements to print, and if necessary specify a title to insert at the top of the sheet.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 54)
Fig. 79
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 54)
Fig. 80
Page 55 of the Get DATA MANAGER-SOFTWARE user manual — ADD/DELETE ELEMENTS TO PRINT BUTTONS
Page 55 · click to enlarge
Page 55

In the first tab on the window, Print configuration, it is possible to select a title which will be shown on each of the printed sheets. In the subsequent tabs (Analysis, Tracks, Report) on the other hand, it is possible to specify the elements to print and a subtitle relative to each of the elements. In order to add an element to be printed, select it from the list on the left (by clicking over it with the left-hand mouse button) and press the >> button, To delete from the elements to be printed, select it from the list on the right and press the << button. Once all the desired elements have been added, press the OK button. In this way, the print preview is displayed automatically. In order to navigate between the print preview pages, use the Next page and Previous page buttons, available at the top of the window. Press the Print… button to continue with printing or the Close button to close the preview.

SUBTITLE FIELD

Get DATA MANAGER-SOFTWARE — SUBTITLE FIELD diagram (page 55)
Fig. 81
Get DATA MANAGER-SOFTWARE — SUBTITLE FIELD diagram (page 55)
Fig. 82
Get DATA MANAGER-SOFTWARE — SUBTITLE FIELD diagram (page 55)
Fig. 83

ADD/DELETE ELEMENTS TO PRINT BUTTONS

Get DATA MANAGER-SOFTWARE — ADD/DELETE ELEMENTS TO PRINT BUTTONS diagram (page 55)
Fig. 84
Get DATA MANAGER-SOFTWARE — ADD/DELETE ELEMENTS TO PRINT BUTTONS diagram (page 55)
Fig. 85
Page 56 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 56 · click to enlarge
Page 56

The print preview can also be reached through the heading Print preview from the File menu. The heading Print… from the same menu brings up the print window. 3.2.20 Advanced options By clicking on the heading File from the main program menu, it is possible to access certain advanced options, through the headings Cut session…, Export…, Convert sxr file…

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 56)
Fig. 86
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 56)
Fig. 87
Page 57 of the Get DATA MANAGER-SOFTWARE user manual — INTERVAL OF TIME SELECTION
Page 57 · click to enlarge
Page 57

3.2.20.1 Trimming a session If the user wishes to copy a part of the session in use and save it on a new session file, it is necessary to use the Trim session function. This function will be found in the MX2 File menu. Once the window has opened, select the position and the name of the new session file to be created by clicking Save as… The file save dialog box will be opened. Next, at the bottom of the window, select the interval of time or the laps to trimmed and used in the new session. Click on Trim to begin the process of creating a new session. The saved file can be analysed again by opening the session which has just been generated.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 57)
Fig. 88
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 57)
Fig. 89

INTERVAL OF TIME SELECTION

BOX

INTERVAL OF LAPS SELECTION

BOX

START TRIM SESSION BUTTON

Page 58 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 58 · click to enlarge
Page 58

3.2.20.2 Export functions The data displayed in the form of graphs in the analysis window can be exported to a Txt or Xml file. Clicking on the heading Export… from the File menu opens the data export window. The top of this window is composed of the controls for selecting the file in which to save the data. Clicking Browse opens a window in which it is possible to specify the path, name and type of file for saving the data. There are two types of file which can be exported : Txt and Xml. The first allows the user to view the data quickly while the second is useful as, being a standard format, it may later be imported for use by other software. The part of the window immediately below, on the other hand, provides the controls for selecting the channels to export. The channels available on the list are only those displayed on the current tab of the analysis window. In order to enable a channel for export, click on the corresponding selection control in the Export column so that a tick appears. To ensure that the channel is not exported, click on the same control to erase the tick The next column, called Hertz, provides an indication of the frequency at which the channels have been acquired (sampling frequency). In the next column, called Output frequency limit [Hz], it is possible to specify a frequency limit at which each individual channel is exported. This means that if, for example, a channel is sampled at 100Hz (100 times a second), it is possible to set a frequency limit of 50Hz so that the values are exported at half the base frequency. The control located at the bottom of the window, called Time interval, allows the user to specify whether to export the data relative to the whole session in use, or whether to export only the data belonging to the display interval in the analysis window. Once the file for export has been selected, the channels have been set and the time interval has been chosen, click on OK to begin the export procedure. A message will be displayed when the procedure has finished. 3.2.20.3 Converting an sxr file The sxr file conversion function allows the user to open a file with a .sxraw extension (GET acquisition device raw data format) and to save it in the format compatible with the MX2 software. This function normally takes place when the data is being downloaded from the instrument (see chapter 4.2 of this manual) and, unless there are any particular conditions, it is never requested from the user.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 58)
Fig. 90
Page 59 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 59 · click to enlarge
Page 59
  • 4 THE DATA MANAGER MAIN WINDOWS The Data Manager main window is displayed by clicking on program icon .
  • Download Data: it manages and stores the data inside the PC
  • Config Datalogger: it is the configuration tool for supported WinTAX4 GET data loggers.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 59)
Fig. 91

Download Data:

Config Datalogger:

Show 5 more labels / short text on this page
data manager · software · GET data loggers · configuration · manager
Page 60 of the Get DATA MANAGER-SOFTWARE user manual — A
Page 60 · click to enlarge
Page 60
  • 5 THE “Download Data” MANAGER The Download Data main window is displayed on picture below:
  • A: Data storage settings
  • B: Command area for connected devices
  • C: Tools menù
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 60)
Fig. 92

A

B

Page 61 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 61 · click to enlarge
Page 61
  • 5.1 The Data Storage Settings Area The Data Storage Settings sets the archiviation folders for downloaded datas. The storage path is based on following structure: “ Base directory ” \ “ Track ” \ “ Session ” \ “ Vehicle Name ” \ “ Run_name ” Where:
  • Base directory: it is the main folder of storage path (the hard disk letter is also included). It is defined by Base directory field in Download Data . The default directory is C:\WinTAXWorkspace . A different path can be selected by click on Base directory selection button .
  • Track: it is the first sub directory of storage path. User can modify the Track field in Download Data in order to change the directory name. PLEASE NOTE: the directory is always create by the software, the default settings is Track .
  • Session: it is the second sub directory of storage path. User can modify the Session field in Download Data in order to change the directory name. PLEASE NOTE: the directory is always create by the software, the default settings is Session .
  • Vehicle Name: it is the third sub directory of storage path. User can modify the Vehicle Name field in data logger configuration (see Config Datalogger section of this manual and the datalogger User Guide for more informations) to set a new folder name.
  • Run_name: it is the last sub directory of storage path. Its name is Run_ followed to a progressive session index number created by the data logger (in our example it is represented with XXX ). Also the Run Comment ) text (if it is present) will be added to the folder name. The picture below show the Data Storage Settings Area: For example the storage path of picture above will be: c:\WinTAXWorkspace \ Track \ Session \ Car \ Run_XXX_Test Where: Car is set in Vehicle Name field of data logger setup Run_XXX is the progressive index of data Every field contains a drop down list that makes fast and easy the selection of last inserted settings.

Base directory selection button Base directory

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 61)
Fig. 93
Show 4 more labels / short text on this page
Track · Session · Run name · Test
Page 62 of the Get DATA MANAGER-SOFTWARE user manual — 5.2 Command area for connected devices
Page 62 · click to enlarge
Page 62

5.2 Command area for connected devices

  • The command area for connected devices features are:
  • Choose and download the data onto the PC
  • Delete the data files from datalogger memory
  • Manually start and stop of data recording (if it is set in data logger configuration) For more informations please refer to the data logger owner’s manual. 5.2.1 Downloading recorded data (manual mode)
  • Please follows the instructions below (manual downloading procedure for M40 data loggers):
  • Switch on the M40 (greed led on fix) and connect to the PC (both LEDs will blink together) by using the proper USB cable.
  • Wait that Windows detect the instrument (the message will be likely in the right low part of the monitor, nearby the clock).
  • Wait that instrument will be present in Devices and Sessions field and select it with a click.
  • If needed, you can stop acquisition pressing Stop Acquis in the right part of Download Data page
Get DATA MANAGER-SOFTWARE — 5.2 Command area for connected devices diagram (page 62)
Fig. 94 · 5.2 Command area for connected devices

Test

Page 63 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 63 · click to enlarge
Page 63
  • Click on to the cross at the left of the device name in order to see stored sessions’ (Run) list
  • Select the needed session with left click(blue background).
  • Click on Download File and wait until the end of operation.
  • Data will stored in the selected storage folder (see chapter 5.1 )
  • At the end of download a message will appear: the device has to be disconnect from the PC (if the high speed downloading mode is selected – see chapter 5.3.2.1) .
  • Confirm the operation pressing OK : the window of Download Data will disappear.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 63)
Fig. 95
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 63)
Fig. 96
Page 64 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 64 · click to enlarge
Page 64
  • 5.2.2 Erasing the recorded data from data logger Please follows the instructions below (manual downloading procedure for M40 data loggers):
  • Switch on the M40 (greed led on fix) and connect to the PC (both LEDs will blink together) by using the proper USB cable
  • Wait that Windows detect the instrument (the message will be likely in the right low part of the monitor, nearby the clock).
  • Wait that instrument will be present in Devices and Sessions field and select it with a click.
  • Click on Delete All button: all of datas will be deleted from the data logger memory (the confirm message will be likely in the right low part of the monitor, nearby the clock).
Page 65 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 65 · click to enlarge
Page 65

5.3 Tools menu The Tools menu contains the options settings of Data Manager software. 5.3.1 “Convert”: the data format converter The Convert feature allows the conversion of logged data (saved like .sxd or .sxraw or .sxr format) in .ztx file format (the data type compatible of WinTAX4 analysis software). Proceed as follows: • Click on Convert in Tools menu: the selection file window will be displayed. Find the file for conversion inside your PC. PLEASE NOTE: the type of file (.sxd or .sxraw) for conversion can be selected from the drop down list menù showed in picture below.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 65)
Fig. 97
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 65)
Fig. 98

Type of file selection list

  • Click on Open to start the conversion process: the output file will be saved in archiviation path set in Download Data .
Page 66 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 66 · click to enlarge
Page 66
  • 5.3.2 The software Options The Options menu is displayed on picture below: User can access to the options simply by clicking on the items on the left side. 5.3.2.1 “Download File” settings Click on Download File item : the following settings window will be displayed: The available options are:
  • Download Mode: set how the software starts the data downloading when the data logger is connected to the PC. The available choices are: Manual (default setting) : the data download starts as describe at chapter 5.2.1 Automatic: the data download starts as soon as the datalogger is connected and recognized from the PC
  • Download Speed: set the data downloading speed. The available choices are: High Speed (default setting) : the downloading speed is set to maximum (if data logger support this feature). If data logger doesn’t support this option the normal download speed is being set. Normal: the download speed is permanent set to normal speed. PLEASE NOTE: if normal speed is selected it isn’t necessary to disconnect the datalogger from PC after data downloading.
  • Automatic WinTAX conversion: enable or disable the automatic WinTAX4 data conversion.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 66)
Fig. 99

Download File · Download File · Options

Page 67 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 67 · click to enlarge
Page 67

5.3.2.2 “COM Options”: disabling the communication serial ports Click on COM Options item: the following settings window will be displayed: The available options are: • Exclude port...: it disables a specific serial COM port (detected by the operating system) from the automatic scanning of connected data logger. Try to exclude the COM port in case of error during device recognition or if wrong devices are detected in Devices and Sessions windows. 5.3.2.3 “General Options”: set the software language Click on General Options item: the following settings window will be displayed: The available options are: Select language: set the language of Download Data and Config Dalalogger softwares (a software restart is required).

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 67)
Fig. 100
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 67)
Fig. 101
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 67)
Fig. 102

COM Options · COM Options · settings

Page 68 of the Get DATA MANAGER-SOFTWARE user manual — B
Page 68 · click to enlarge
Page 68
  • 6 THE “Config Datalogger” MANAGER The Config Datalogger main window is displayed on picture below: The components of Config Datalogger are:
  • A: menu bar
  • B: horizontal icons bar
  • C: vertical icons bar
  • D: Data logger setup area User can setting up the owned data logger (sensor calibration, logging mode, etc…) by using the setup editor window shown in picture above. The real-time monitoring feature for datalogger and the connected sensors is also available and it’s called Watch . All settings can be saved in a .sxs file defined as setup file. For more informations please refer also to the data logger owner’s manual.

A

Get DATA MANAGER-SOFTWARE — A diagram (page 68)
Fig. 103

B

D

Page 69 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 69 · click to enlarge
Page 69
  • 6.1 Menu bar The menu bar contains the commands of Config Datalogger , see following chapters for more informations. 6.1.1 File menu The commands in File menu are:
  • Save : save the data logger setup file inside the PC.
  • Save as : save the data logger setup file with ad different name.
  • Import Sxraw: extract a setup file from an .sxraw session.
  • Export Sxraw: convert a setup file (obtained by Import Sxraw function) to a .sxraw file. In this way the user can edit the channel calibration in order to post-calibrate the acquired datas.
  • Close : stop the Config Datalogger software. 6.1.2 Menù Setup Following are the Setup menu items:
  • Send Setup to Device... : send the setup to the connected data logger.
  • Send time : synchronize the data logger clock to the PC clock.
  • Sync Track Library: download the track library from PC to in the data logger.
  • Create New... : create a new empty setup file for own data logger (user can choose the proper device from a list).
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 69)
Fig. 104
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 69)
Fig. 105
  • Open From Disk... : open a setup file stored in the PC.
  • Open From Device : download the data logger setup from a connected device.
  • Close Active : close the loaded and selected setup in Config Datalogger software.
  • Rename: modify the name of loaded and selected setup : this feature doesn’t modify the saved setup filename but the name displayed in Config Manager window. We suggest to keep the default names.
  • Calibrate Channel : open the calibration window of selected channel.
  • Copy Channel : copy the selected channel properties (calibrations, logging rate, etc.. ) to another channel of the data logger setup (it makes fast the creations of many similar channels). 6.1.3 Watch menu Following are the Watch menu items:
  • Start/Stop Watch : run or stop the real-time monitoring when the Watch window is a displayed.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 69)
Fig. 106
Page 70 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 70 · click to enlarge
Page 70

6.1.4 Device menu Following are the Device menu items: • Send Configuration : send a configuration file (.cfg format) to the data logger. This feature is supported only to MD3 dash family.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 70)
Fig. 107
Page 71 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 71 · click to enlarge
Page 71

6.2 Horizontal icons bar The horizontal icons bar is represented in picture below: The available features are :

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 71)
Fig. 108

Open From Disk... : open a setup file stored in the PC. Create New... : create a new empty setup file for own data logger (user can choose the proper device from a list). Send Setup to Device... : send the setup to the connected data logger. Open From Device : download the data logger setup from a connected device. Send time : synchronize the data logger clock to the PC clock. Sync Track Library: downloads the track library from PC to the data logger. Send Default Track: set the default track from PC to the data logger . Receive Track Library: downloads the track library from data logger to the PC. Send Configuration : send a configuration file (.cfg format) to the data logger. This feature is supported only to MD3 dash family.

Page 72 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 72 · click to enlarge
Page 72

6.3 Vertical icons bar The vetical icons bar is represented in picture below: The available features are :

Setup Editor: show the editor setup window when, for example, Watch function is running.

Watchrun the Watch window

MD3 Manager: run the dash configuration software for MD3 data logger.

Page 73 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 73 · click to enlarge
Page 73

6.4 Setting up data logger In order to setting up own data logger refer to device user guide.

Page 74 of the Get DATA MANAGER-SOFTWARE user manual — ICONS
Page 74 · click to enlarge
Page 74
  • 6.5 WATCH With WATCH , in Setup Manager you can:
  • Read live sensors values
  • Calibrate sensors
  • Set 0 (really useful in cases, as suspension potentiometer, when the value can be positive or negative)
  • Set offset Using WATCH it is compulsory to switch on and connect a data logger to PC. 6.5.1 Start and stop “WATCH”: real time channel visualization This procedure shows visualization of two analogue channels: operations are the same for all of M40 parameters. Start WATCH as described:
  • Download the device’s setup in to the PC by clicking the icon or clicking Open from Device in Setup menu.
  • Once the job is done, a message will appear and you will see the setup in Setup Manager .
  • Click on WATCH icon to see channels list visualization
  • If we wish to read live AD1 and VBAT channels, we select boxes in Watch column
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 74)
Fig. 109

ICONS

“WATCH” ICON

Get DATA MANAGER-SOFTWARE — ICONS diagram (page 74)
Fig. 110
Get DATA MANAGER-SOFTWARE — ICONS diagram (page 74)
Fig. 111

“Open From Device”

Page 75 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 75 · click to enlarge
Page 75
  • If we wish to read live AD1 and VBAT channels, we select boxes in Watch column
  • Click on Start Watch in “instrument bar” or select Start Watch in Watch menu: the software will show selected values.
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 75)
Fig. 112

ICONA “ Avvia Watch”

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 75)
Fig. 113
Page 76 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 76 · click to enlarge
Page 76
  • In order to freeze WATCH , click again Active Watch , or select Stop Watch in Watch menu NOTE: the value, visualized in WATCH, is given by channel calibration. WARNING: to get back to Setup Manager window, click on the icon on the left of the WATCH window

“Active Watch” ICON · “Setup Manager” ICON

Page 77 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 77 · click to enlarge
Page 77

6.5.2 “WATCH” channel calibration Calibration is necessary to convert signals from sensors to comprehensible data. This operation can be done during the channel creation (read previous chapters) or in WATCH window, clicking on Calibrate button (corresponding to the required channel) without starting WATCH . We suggest to use this function only after the channel is configured in M40 setup.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 77)
Fig. 114

Once the button Calibrate is pressed, you will see the calibration window. The procedures are the same of previous chapters. Once the channel is calibrated, you need to send again the setup to the device. You can do this directly from WATCH selecting “Send Setup to Device” in File menu o by clicking the icon (second from the left in instrument bar).

Page 78 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 78 · click to enlarge
Page 78

6.5.3 Setting channel zero in “WATCH” Zero set is useful when using some kind of sensor (for example suspension potentiometer or internal accelerometer). To use this function WATCH need to be activated (read chapter 6.5.1 of this Appendix) and the sensor need to be in “zero” position. To set the zero, press “Set Zero” of the required channel: We suggest to send back the setup once “zero” operation are finished. We suggest to use this function only after the channel is configured in data logger setup.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 78)
Fig. 115
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 78)
Fig. 116
Page 79 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 79 · click to enlarge
Page 79

6.5.4 Setting channel offset in “WATCH” Sometimes it is needed to add or remove a defined value from a sensor reading (wrong “zero” of a suspension potentiometer). To set this we will use the Offset button: Set the value in dialogue box: Use positive values to subtract the offset to the channel and use negative values to add; press OK to confirm. 6.5.5 WATCH: Quick search The item Quick search found in the main toolbar of the Watch dialog box, allows you to do a quick search of channels available in the lower part of the dialog box. When you enter the whole or partial name of a channel in the appropriate field, the list below is updated showing only channels with the name included in the text entered. 6.5.6 WATCH: Filtro sui canali The next part of the toolbar of the Watch dialog box, allows you to filter the channels shown according to their type. If you click on the items Digital, Analog, System, Gaps, Can, Math, the underlying list of channels will show only the type specified.

Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 79)
Fig. 117
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 79)
Fig. 118
Get DATA MANAGER-SOFTWARE — SHOW/HIDE REFERENCE diagram (page 79)
Fig. 119
Page 80 of the Get DATA MANAGER-SOFTWARE user manual — NOTE / NOTES:
Page 80 · click to enlarge
Page 80

NOTE / NOTES:

Page 81 of the Get DATA MANAGER-SOFTWARE user manual — NOTE / NOTES:
Page 81 · click to enlarge
Page 81

NOTE / NOTES:

Page 82 of the Get DATA MANAGER-SOFTWARE user manual — NOTE / NOTES:
Page 82 · click to enlarge
Page 82

NOTE / NOTES:

Page 83 of the Get DATA MANAGER-SOFTWARE user manual — NOTE / NOTES:
Page 83 · click to enlarge
Page 83

NOTE / NOTES:

Page 84 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE
Page 84 · click to enlarge
Page 84
Page 84 of the Get DATA MANAGER-SOFTWARE user manual — SHOW/HIDE REFERENCE

Ask about the Get DATA MANAGER-SOFTWARE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Get DATA MANAGER-SOFTWARE

Be the first to ask — other owners or our team will answer.

Original document

Get DATA MANAGER-SOFTWARE manual PDF

84 pages·6.6 MB·Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…