Installation instructions

40010678 - 0904


B


1.2 1.3


1.4 1.5
30cm




B
2.2 2.3


2.4 2.5



2.6 2.7


2.8 2.9


3.0 3.1



3.2 3.3

4 <



5.1 5.2


5.3 5.4


1 Introduction 8
2 Safety notices 8
3 Installation requirements 9
3.1 Fireplace 9
3.2 Booze 9
3.3 Requirements for drainage channel and exits 9
3.4 End-points 10
3.5 Existing chimney 10
4 Preparation and installation instruction 11
4.1 Gas connection 11
4.2 Electrical connection 11
4.3 Preparation of the fireplace 11
4.4 Installation of the fireplace 11
4.5 Assembly of flue gas drainage materials 12
4.6 Building bosom 12
4.7 Booze 12
4.8 Frameless without optional decoration plate 13
4.9 Frameless with optional decoration plate 13
5 Glass out 14
5.1 Glass removal front 14
5.2 Glass removal side 14
6 Installation of decoration material 15
6.1 Wood set 15
6.2 Gravel 15
7 Installation control 16
7.1 Control of ignition flame, head burner 16
7.2 Gas leakage control 16
7.3 Checking of burner pressure and prepressure 16
7.4 Flame image check 17
8 customer instruction 17
9 Annual maintenance 18
9.3 Cleaning the glass 18
10 Conversion to other gas types (e.g. Propane) 18

11 Disposal calculation 19
11.1 Points of interest: 19
11.2 Example calculations 20
12 Stitch table 21
13 Technical specifications 22
14 Model drawing device 23
15 Size drawing Ventilation grid 24
16 Size drawing Control cover 25

The fireplace may only be installed by a qualified installer/dealer.
We strongly recommend that these installation instructions be read properly.
This appliance complies with the guidelines for European Gas Appliances (GAD) and carries the CE
marking.
2 Security notices.
installation instructions and applicable national and local requirements.
Busy.
- Burning chamber.
Surfaces, including glass, can become very hot (hotter than 100°C)
Except for this, the underside of the fireplace and control buttons are.
the fireplace.
hardened volatile constituents from paints, building materials and floor coverings, etc.
sucked in. These constituents can be found on cold surfaces as soot
Turn it off. Therefore, do not light the fireplace shortly after a renovation.
gets to harden out. Ensure adequate ventilation, so that any
vapours released are discharged. We recommend to keep as little in the
space during this process.
1 all transport containers have been removed.
2 children and pets are not present in the room.

3.1 Fireplace
mounted on the right side of the fireplace. unscrew and mount them
a distance of max. 30 cm behind the control hatch.
line block support is fixed, can now be mounted on the top of the control block
to be pushed. The transporter can be omitted.
3.2 Booze
a comparable alternative with minimum free passage of 200cm2.
fibreglass wallpaper for discoloration and cracks, etc. to be avoided.
Minimum drying time 24 hours per mm finish.
3.3 Requirements for drainage channel and exits
BV. Only using these materials can be used
The Commission has also proposed to the Council that it be given a mandate for this purpose.
in the case of transit through flammable wall or ceiling insulation structures; and
protection. And keep a sufficient distance.
meter is held so that the weight of the material does not hit the fireplace
rest.
start

3.4 Ends
The combined supply and disposal can pass through both the façade and the roof.
Check that the exit you want meets local requirements
concerning discomfort and ventilation openings.
For the purpose of proper operation, the exit point shall be at least 0,5 m from:
3.5 Existing chimney
You can also connect the fireplace to an existing chimney. The existing chimney
then functions as air supply and a flexible stainless steel pipe pulled through the chimney
exhaust gases
The flexible stainless steel tube of Ø 100mm must have a CE mark up to 6000
The chimney shall then meet the following conditions:
o No leakage and
o Cleaned up well
For more information on the connections to existing chimney channels, see
Manual .

4.1 Gas connection
The gas connection must comply with local standards.
We recommend a gas connection of Ø 15mm directly from the gas meter to the device,
with a valve in the vicinity of the device which is always accessible.
Position the gas connection so that it is easily accessible, and for service
burner unit can be dismantled at any time.
4.2 Electrical connection
If an adapter is used for the power supply, it must be possible to use a
wall socket 230VAC . 50Hz near the fireplace.
4.3 Preparation of the fireplace
the device is not damaged.
4.4 Installation of the fireplace
Takes into account the Installation requirements (see Chapter 3)
4.4.1 Floor standing
Set the device in place and adjust height with the struts if necessary.
Adjust height and adjust the fireplace. (see Fig. 1.3)
o with the extendable leg, or with long legs supplied.
o with the swivel-adjustable legs.

4.4.2 hanging on the wall
The device can be attached to the wall by hanging. included suspension bracket
and keilbolten (see Fig. 1.4). These fasteners are intended only for use in the manufacture of
assembly to brick or concrete walls. For walls of other materials,
for example, hollow building blocks, consult the specialist trade.
4.5 Mounting of flue gas drainage materials
then the diameter of the drain material.
(3 degrees).
be made of a sliding intersection.
Meter-short pipe. Make sure the inner pipe is always 2 cm longer than the
Outpipe. The facade and roof throughput are also shortable. These parts must be fixed
be set with a parking lot.
4.6 Build a bosom.
Before the bosom is placed we recommend to perform a functioning test with
to carry out gas fireplace as defined in Chapter 7 . .
4.7 Booze
Profiles or of brick/cell concrete blocks.
above the grids a screen plate (see Figure 1.1-A) of non-combustible material.
be placed directly on the fireplace.

4.8 Frameless without optional decoration plate
3mm play between bosom and device in connection with the release of the
Fireplace.
4.9 Frameless with optional decoration plate
the lower part. Keep a minimum clearance of 3mm between bosom and
apparatus related to the setting of a fireplace.
Recesses. (See Fig. 1.2)

5.1 Glass removal front
gradually the glass outwards and downwards. (see Fig. 2.7 and 2.8)
5.2 Glass removal side
There is no need to remove the side glass for placing the wood set or
for performing maintenance.
gradually the glass inwards and downwards. (see Fig. 3.2 and 3.3)
Repositioning the glass goes in reverse order.
Remove all the Fingerprints on the glass, which will burn in when the fireplace becomes
is used.

It is not permitted to add other or more material into the combustion chamber.
Always keep the flame free of decoration material!
Do not throw all decoration material on the burner at once; through the dust parts it can be
Hide.
6.1 Wood set
wood set-card).
on the burner; this affects the fire image.
Flame distribution is good. Move the chips if necessary until a good flame distribution
The Commission's proposal is not a good one.
6.2 Gravels
wood set-card). Avoid a double layer; this will affect the fire image.

7 Installation control.
7.1 Control of ignition flame, head burner.
Light the fireplace as described in the user manual.
chips, a log or pebbles.
(the ignition must be smooth and quiet).
7.2 Gas leak control.
Check with a gas leak seeker or spray all connections and compounds for any
Gas leaks.
7.3 Checking of burner pressure and prepressure
Check that the burner pressure and prepressure correspond to the data on the plate
Pre-pressure measurement:
on the gas control block.
Measure burner pressure:
Check the burner pressure only at proper prepressure.
on the gas control block.
contact the manufacturer.
*Close all pressure gauges and check for gas leakage.

7.4 Flame Image Control
Let the fireplace burn for at least 20 minutes and then check it
Flame image on:
If one or both points are not acceptable, please check:
o Wall throughput the right side above and correct position
o Roof throughput the correct position
checked to ensure safe use and long life
including replacement of batteries and adjustment of the receiver.
o Woodset Instruction card
o Installation instructions · o User's manual · o Suction cups

9.1 Control and cleaning:
o The burner (In LPG flat burner replace the fire racks)
o The logs on if. Fracture.
O The exhaust.
9.2 Replace:
o At LPG flat burner, the fireplaces.
o If necessary, the chips/embers.
9.3 Cleaning the glass
Most of the attack can be removed with a dry cloth. With ceramic
hotplate cleaner you can clean the glass.
Now perform the check as described in Chapter 7 . .
This can only be done by installing a proper burner unit. Please contact your
supplier.
Always indicate the type and serial number of the device when ordering.

The possibilities of drain lengths and the possible thrust are defined in a
Table of drivers (see Chapter 12). This table is based on a vertical and
horizontal length.
the vertical direction is added up.
- The roof throughput always counts for 1 meter
in the horizontal direction, add:
- every 90° bend in the horizontal section is 2 meters.
- every 45° bend in the horizontal section counts for 1 metre.
- Bends from vertical to horizontal or vice versa do not count for
the calculation.
- The facade throughput always counts for 1 meter.
If dragged below 45°, the actual vertical and horizontal lengths shall be:
The Commission's proposal is based on the following principles:
11.1 Points of interest:
Slide over is more than 1 meter.

11.2 Example calculations

Count the horizontal lengths
Tube lengths C+E = 1 + 1 2 m
Bend D = 1 x 2 m 2 m
Count vertical lengths
Tube length A 1 m
Roof transit G 1 m

Count the horizontal lengths
Tube lengths J + L = 0,5 + 0,5 1 m
K+M bends = 2 + 2 m 4 m
Total horizontal length 6 m
Count vertical lengths
Tube length H 1 m

See table at the correct vertical and horizontal length.
In the case of a .x.x and if values are not included in the table, the combination is not permitted.
The value found indicates the width of the drive to be placed ("0" does not mean a thruster
places).
A 30mm thruster is mounted as standard.



Set to gas type G25 G30 G31 G20 G30G31
Load Hi kW 9.7 9.0 7.9 9.7 9.8 8.8
(At 15oC and 1013mbar) g/h 507 590 507 650
Burning pressure full mbar 16.5 25.5 25,5 12,0 25,5 31,5
Injectioner head burner mm ST.800 ST.280 ST.2 80 ST. 800 ST.285 ST.283
Code Injector No. 36 No. 23 No. 23 No. 36 No. 23 No. 23
Diameter aan/afvoer mm 100-150
Electric connection V 220V 220V 220/200V 220 V 220 V
Batteries transmitter V 9V 9V 8V 9 V 9 V








www.faber.nl - [email protected]
Saturn 8 EN - 8448 CC Heerenveen
PO Box 219 EN 8440 AE Heerenveen
F. +31(0)513 656501