EN
Faber logo
Official user manual

Faber MatriX 1050

12 pages·946 KB·Fireplace·PDF·ENDEFRITNLJA
Faber MatriX 1050
Table of Contents 13 sections User Manual MatriX I.T.C. Honeywell EN · .Intelligent Technical Controller . · 40011718-1909 · 1 < · … ShowHide
Page 1 of the Faber MatriX 1050 user manual — 40011718-1909
Page 1 · click to enlarge
Page 1

User Manual MatriX I.T.C. Honeywell EN

.Intelligent Technical Controller .

Faber MatriX 1050 — .Intelligent Technical Controller . diagram (page 1)
Fig. 1 · .Intelligent Technical Controller .

40011718-1909

Faber MatriX 1050 — 40011718-1909 diagram (page 1)
Fig. 2
Page 2 of the Faber MatriX 1050 user manual — 1 <
Page 2 · click to enlarge
Page 2

This user manual is intended for the following gas burners:

MatriX 800/500 I, II, III

MatriX 1050/500 I, II, III

MatriX 800/650 I, II, III

MatriX 1050/650 I, II, III

MatriX 800/500 RD, ST LL

Registration plate/Type shield/Type plaque:

NLSerial Number
ENGSerial number
DESerial Number
FRNuméro de série
ESPNúmero de serie
NOSerial Number
ITNumero di series
PLNumber seryjny

1 <

MatriX 800/400 I,II,III · Matrix 1050/400 I.II,II · Ma triX 1300/400

Page 3 of the Faber MatriX 1050 user manual — 2 <
Page 3 · click to enlarge
Page 3
Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 3
Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 4

1.0 1.1

Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 5
Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 6

1.2 1.3

Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 7
Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 8

1.4 1.5

Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 9
Faber MatriX 1050 — 2 < diagram (page 3)
Fig. 10

1.6 1.7

2 <

Page 4 of the Faber MatriX 1050 user manual — 3 <
Page 4 · click to enlarge
Page 4

Boil after a renovation. The natural air circulation takes moisture and non-hardened volatile matter from paints, building materials and floor coverings into this air circulation. These constituents can be placed as soot on cold surfaces. The moment you can start using the fireplace for the first time depends on various circumstances. Please consult your installer/dealer. The apparatus is designed for ambient and heating purposes. This means that all visible surfaces, including the glass, can become hotter than 100°C. Do not use the remote control and/or App outside of the space where the fireplace is set up. So that you are always aware of the situation around the fireplace when it is operated. The fireplace shall not be used when: the glass is damaged or removed, or when the combustion chamber is open. Do not place combustible materials in the combustion chamber. Never change the arrangement of the wood set and do not add more decoration material than what is supplied with the fireplace. Do not place curtains, clothes, furniture or other combustible materials near the device. The minimum distance is 0.5 metres. Have children only use the remote control under supervision.

Congratulations on purchasing your Faber product! A quality product that will give you the warmth and atmosphere of many years. We advise you to read the instructions carefully before starting use of the fireplace. If there is a malfunction despite the careful final checks, you can contact your dealer or Glen Dimplex Benelux B.V. at any time.

To claim the guarantee it is important that you register the fireplace. You can find the details of your fireplace on page 1 of this user manual or in the App. (See 8.1). You can register your fireplace at: www.faber-fires.eu Glen Dimplex Benelux B. V. Address: Saturn 8 NL-8448 CC Heerenveen Tel: +31 (0)513 656 500 Email: info@faber-fires.eu Info: www.faber-fires.eu

Check the fireplace for transport damage and report any damages to your supplier immediately.

Installation and maintenance of the apparatus shall be carried out by a professional professional with proven knowledge and demonstrable competence. A professional professional takes into account all technical aspects such as heat release, gas connection and flue-gas discharge requirements. Where the installation requirement is not clear, national/local regulations should be followed.

First time in use of the fireplace

Provide extra ventilation and open all windows of the room during first use of the fireplace. Light the fireplace for a few hours at its highest position so that the paint can be hardened and any vapours released are safely removed. Keep vulnerable persons and pets out of this room during this process!

User safety instructions

Please note: It is recommended to always install a fireplace screen when there are children, elderly or disabled persons in the same room. If vulnerable persons can be present in the room regularly without supervision, a fixed shield around the fireplace shall be installed.

Every year the appliance will have to be cleaned and checked for proper operation by an installer. The outside of the fireplace can be cleaned with a clean damp cloth. Cleaning of glass Disassemble the glass as described in the installation instructions.

As a fireplace is a heat source, hot air circulation occurs. Therefore, it is important that you do not rush the fireplace too quickly

3 <

Show 4 more labels / short text on this page
Dear User · Check · Introduction · Cleaning and maintenance
Page 5 of the Faber MatriX 1050 user manual — 4 <
Page 5 · click to enlarge
Page 5

With Faber glass cleaner you can clean the glass. This is a specially formulated cleanser that you can order from the authorized Faber dealers. Never use aggressive cleaning agents or abrasives. Watch this!

and after checking the safety system immediately re-activated and returns to the position where the device was in for control. Watch this!

If it is no longer possible to control the fireplace with remote control or app, then you can switch on/off using the ON/OFF button on the I.T.C. controller, see Fig. 1.4. (This is located behind the control hatch) Fireplace OFF: Press/Unbutton briefly. Fireplace ON: Press the button until the LED turns green. (In case of earlier release, the start is broken off). With longer pushes, the flame goes from low to high and from narrow to wide. Leave the button loose at the time when desired mode The Commission has already made a number of proposals. If the button is not released, the fireplace will automatically switch off again. (If the button exceeds 5 min. is pressed, gives the I.T.C. controller an error message that may have broken the button and service is desired).

Avoid fingerprints on the glass. These can burn and are then no longer removable.

Operation I.T.C. .Intelligent Technical Controller • (fig. 1.4)

The I.T.C. controller controls, checks, records the usage and displays warning and error codes if necessary. The I.T.C. controller is not connected to the Internet and therefore outside access for third parties. Only in combination with the optional Domotics Interface Unit can long-distance connection be achieved if desired. Control is possible with remote control, Smartphone or Tablet. All 3 use a Bluetooth connection to the fireplace. It has a limited reach so you should always be near the fireplace. Initial procedure The fireplace starts with a built-in procedure. This procedure may vary by type of fireplace. During this procedure, no command fuse can be given On the remote control it is visible by a white flashing LED and in the App it is made visible on screen. If a start procedure is terminated by the user or the fireplace does not turn on after completion of the starting procedure then there is a waiting period of 30 seconds after disabling. before restarting. The waiting time is increased with multiple start attempts. After 3 complete attempts, the I.T.C. blocked for at least half an hour. The I.T.C. recover after this half hour. The waiting time is visible in the App. If the fireplace is switched off during normal use, it is possible to switch on again after 15 seconds. Disable unexpectedly and automatically enable again Twice every 24 hours the burner automaton automatically checks its operation. After 12 hours the first check is but it is skipped if the device actually burns. On the second attempt, 12 hours later, when the device is on, the unit will be turned off for a moment.

Remote control (fig. 1.0)

The remote control is already connected to the I.T.C. controller which makes the fireplace ready for use. If this is not the case, follow the instructions in section 4.1. The remote control enables all basic functions to be activated. To control the thermostat function and change settings, it is necessary to use the Faber App on Smartphone or Tablet. The remote control also functions as a space thermostat and should therefore be placed in an appropriate position in the supplied container. (See Chapter 8). Function button remote control

1. OFF (top left) 2: ON (top right 3: Lower fire (left middle) 4: Higher fire (right middle) 5: Toggle additional burner (bottom left) 6: On/off glowbed (bottom right) The function of button 6 is only available when a Symbio LED module is installed. The LED strength can be set by holding down button 6 and simultaneously pressing one or more times button 3 or 4. This new setting is being saved.

4 <

Page 6 of the Faber MatriX 1050 user manual — 5 <
Page 6 · click to enlarge
Page 6

Watch this! The fireplace shall be switched off if the remote control:

command not by the I.T.C. is confirmed). LED flashes orange (4 times):

is out of reach of the fireplace. no longer connected to the fireplace. The batteries are dead.

o 1 or more I.T.C. Warnings active. (To be read out in the App). LED flashes red (7 times):

o 1 or more I.T.C. errors active. (To be read out in the App).

Connect remote control with I.T.C.

Press the I.T.C. button on controller, which is located behind the control hatch until it flashes blue. (See Fig. 1.5). The LED keeps blinking blue as long as the torque mode is activated (60 sec.). Press the remote control simultaneously button 1 and 5 until the LED flashes blue continuously and lets go of the buttons. (See Fig. 1.3). Now the coupling process starts automatically. If the clutch succeeds, it will be on both the remote control and I.T.C. controller the LED briefly flash green. If the link fails, on the I.T.C. controller and/or remote control the LED flashing red for a short time. If this occurs, repeat the procedure and check that all operations are done properly and reduce the distance between the remote control and I.T.C. Controller. After the coupling procedure stops the blue flashing of the LED. You can also follow the instruction using the App. Click on the main menu at the top left and choose .Info . and then .

The replacement of the batteries in the remote control is indicated by the App on time. You will be given a competition on your Smartphone or Tablet. Watch this!

After replacing the batteries, the remote control does not need to be re-connected with the I.T.C. Controller!

Remove the lid on the back of the remote control. (See Fig. 1.6). Place 2 AA 1.5 Volt. Put the lid back.

Control via Smartphone or Tablet

Suitable for Android or iOS operating system in combination with the free downloadable App: .Faber ITC V2O or higher:

Download and install the App on your device. The Faber App uses a Bluetooth connection to the fireplace for this, it is necessary that your Bluetoeth from your Smartphone or Tablet is enabled. Your Smartphone/Tablet should be linked to the I.T.C. Controller. To do this, follow the instructions in the App or consult 5.1. You can connect an unlimited number of devices.

LED signals in .power . symbol remote control (see fig. 1.1)

LED flashes white:

O Start-up procedure LED Flick orange (1 time):

o Min or max achieved. (Flame height, light intensity etc.) o Start interrupted or unsuccessful (During waiting time no start possible. When using App, the remaining waiting period is displayed). o Too quickly enable after disabling. LED flashes blue (heartbeat rhythm with breaks of 0.5 sec.):

Connecting Smartphone/ Tablet with

I.T.C. controller (by remote control)

Press the remote control on the OFF button (top left) and hold it down until the LED starts blinking blue (heartbeat rhythm) and let go of the button. (See Fig. 1.2). The LED keeps blinking blue as long as the torque mode is activated (60 sec.). Start the App on your Smartphone or Tablet. If the control screen is shown:

o I.T.C. in torque mode (60 sec.) for linking Smartphone/Tablet. LED flashes blue (continuous):

o Remote control in torque mode for coupling with I.T.C. LED flashes green (1 to 4 times):

o Send user command. (Receiver remote control command max 4 times if it

Press the .-list .'- symbol next to its fireplace name in the control panel. If you want to add an extra fireplace:

5 <

Replace batteries remote control

Page 7 of the Faber MatriX 1050 user manual — 6 <
Page 7 · click to enlarge
Page 7

Press the .+ " button at the bottom of the screen. The clutch is now automatically established.

synchronously running with your own home thermostat. You indicate at this setting how much the temperature of the I.T.C. Deviating from your own home thermostat. Determine whether you want to apply open window detection. Finally, you can always delete your personal settings. Notifications The App will notify you when something special happens, such as:

Smartphone/Tablet allows all functions of the I.T.C. The Commission has already taken a decision on the matter. In addition to the standard functions are also available: Thermostat function (see 5.3)

Manual temperature adjustment. Clock thermostat with a day/week program. Flame/light cartridges In addition to a manual setting, you can choose from four different flame patterns that we have carefully compiled:

Maintenance required. Error codes malfunction (with proposed action). Shut down by automatic shutdown function. Empty battery remote control.

Campfire Party Relaxed ECO In addition to a varying flame effect, the Symbio LED module (if any) is provided with a light pattern appropriate to the fire pattern. Within these flame patterns you can adjust the output power and turn on and off the extra burner. Fireplace consumption statistics Gas consumption and burning hours arranged per day, month and year make the cost of use transparent for you. Personal User Settings Here you can even better adapt your fireplace to your needs (see chapter 6):

Standard is thermostat function UIT and clock thermostat UIT. If you have settings under .Thermostat . It is advisable to turn off both functions if the device is placed in a public space and/or is used primarily for decorative purposes. By turning on these functions, the device can turn on and off at any time. In thermostat mode, the I.T.C. switches on. controller automatically insert the extra burner if it is necessary to reach the desired temperature faster. You switch on the thermostat by tapping the thermostat symbol at the bottom right of your screen. Now a screen appears with in the circle a hand showing you are in manual mode. You can now set the desired temperature by moving the point on the circle. If the clock thermostat is released at settings then you can activate the clock thermostat by tapping on the hand. The automatic day/week program is now activated. By moving the point on the circle you can adjust the current temperature setting for the current period. This setting is not saved. If you want to change the day/week program, go to the main menu, select . . settings . and then .

You can change the name "My Fabero' of the fireplace, which appears on your Smartphone or Tablet. If you want to use the thermostat function and possibly also the clock thermostat with day and week setting or not, turn these functions on or off. Determine whether you want to automatically make the glowbed flame-following or not. The factory setting is ON. Set the basic glowbed setting of the Symbio LED module to your desired strength. Determine how you want to display your consumption in m3 gas or kWh. Decide which energy-saving automatic switch off functions you want to activate and determine the conditions for yourself. When calibration is done, you have the possibility to measure the temperature of the I.T.C.

6 <

App Functions · Thermostat function

Page 8 of the Faber MatriX 1050 user manual — 7 <
Page 8 · click to enlarge
Page 8

Watch this! The apparatus shall be automatically switched off in the thermostat function if:

By tapping the top circle, the extra burner is switched on or off. Campfire flame pattern A 13 minute animation of a real campfire with continuously varying flames and a modulating glow bed variation. The fire starts with a slightly faint glowing bed. Slowly the fire becomes hotter and the flames higher and the glow bed becomes stronger and warmer (more red) in color. At the end of the phase, just like with a real wood fire, the flames become smaller but the glow bed becomes stronger and more red in color. If the flames are minimal for some time, then also slowly decrease the glow bed. There are now 13 mins. and the process begins again. By turning the dot on the circle to the right you give more average power and both the duration and height of the flames are adjusted in proportion. You can also turn the extra burner on or off. Relaxed flame pattern A quiet sparkling fire. Movement and frequency are visible but gradual. The pattern is dynamic and unpredictable, and the glow bed also goes along with this pattern of unpredictability. By turning the dot on the circle to the right you give more average power and both the duration and height of the flames are adjusted in proportion. You can also turn the extra burner on or off by tapping into the upper circle. Party flame pattern In Party mode a striking flame is sought that is briefly visible to create a limited heat release assuming the departure will be heated up by many people present. In Party fashion, a lot of movement is sought in both flame height and time. This also comes out in the glow bed. By turning the dot on the circle to the right you give more average power. Only the duration and repetition vary with settings, and the extra burner can be switched on or off. ECO flame pattern In ECO modes, the aim is to save as much energy as possible with a minimum amount of energy still seeking maximum flame experience. Movement and frequency are subtle and not striking.

The thermostat has not switched on the fireplace for 8 days. After 8 hours at maximum power the fireplace has not yet reached the desired temperature. The room temperature measured by the remote control above the maximum value set by the user (default 31 degrees). The remote is out of range from the fireplace.

Fire slowly changes into motion and action. A chosen flame pattern takes about 1 hour to make the flash image come true. Please note that if you start to assess the flame image. Manual setting and flame patterns are switched on by selecting the flame in the App, on the bottom bar. If you have not selected a flame pattern, you will be able to enter the manual mode . Otherwise, the flame pattern you have chosen will be selected. The remote control does not allow you to select flame pattern but it does set the power as shown below in the flame patterns. You use the 3 keys (Fire layer), 4 (Flight high) and 5 (Extra burner on/off) for this. Select Flame Pattern Tap the symbol .flamm pattern . . in the middle of the circle, which will enter you into the pattern selection menu. The flame pattern used is clear in the picture. Now select the desired flame pattern. You can make the choice final by tapping on the arrow in the top bar. You're going back to the control panel. Constant flame pattern This is the default manual setting. The flame image is constant and depends on the position you choose. The glowbed is slightly modulated between 80 and 100% of the basic setting you set for the Symbio LED module. This glow bed setting can be controlled by remote control or the App. (See 6.3 or in the App for menu settings). By moving the point in the circle, the height of the flame varies.

7 <

Flame patterns

Page 9 of the Faber MatriX 1050 user manual — 8 <
Page 9 · click to enlarge
Page 9

Personal settings and device data

Set Manual Thermostat Manual thermostat function is standard AAN. If you do not use the function regularly and for control of the fireplace, the remote control is used instead of the App we recommend to use this feature UIT The Commission has already taken a decision on this matter. You will avoid unnecessary or unexpected enable. Set clock thermostat This is default UIT and can only AAN are set if the manual function AAN State. Set Clock Program The clock thermostat has a day and week function. When switched on, the fireplace automatically tracks the program entered until the fire place is turned off. With this setting, the program can be changed to your own wishes. The programme has the following steps:

Personal settings can only be adjusted with the App.

If you are connected to your fireplace, tap the top left of the menu. Select the top setting, by default the name . . My Faber . You will now enter a screen where all information about your fireplace is listed. Tap . .My Faber . and adjust it.

The device data, which are visible in the screen (see 6.1), is required when requesting service. The list shall contain:

the official name of the appliance; the item number; the serial number; date of installation; and the load on the fireplace in kW. The contact details can be found at Faber click on top of the control menu

Get up Departure Come home Sleeping At each step time and temperature can be set. Watch this!

Go to the menu and select the option "Settings" and then "Glowbed" and "Automatically." Automatically Toggle The glow bed will start when there are flames. If you do not want this then this function can be Deactivated. During use you can temporarily turn the glow bed, with the remote control or app on or off. Adjusting intensity of glow bed Here you can set the basic light intensity of the glowbed. If you select the option, it will turn on the glow bed during setting and you can set the strength by moving the dot onto the circle. The choice you have made will be saved as soon as you leave the setup screen. This setting can also be adjusted when the fireplace is switched on!

Times should be linked to the previous step.

Max room temperature Here you can set the maximum room temperature (default 31 degrees). If the temperature exceeds the set value, the fireplace goes off. This function is intended to disable the fireplace if forgotten, in manual mode, to turn off the fire place when leaving the room. Please note that if the remote control is heated by the sun or in close proximity to the fireplace, the temperature rises very quickly above 30 degrees. Disable time in hours If the fireplace is switched on at manual mode or one of the flame patterns and does not receive a remote control or App command during the set time, then the I.T.C. Turn off the fireplace. As a user, you can set this time between 1 and 24 hours.

The thermostat must be operated properly by installing the remote control in the container at its prescribed location. (See Chapter 8). The room temperature is measured by the remote control.

8 <

Show 5 more labels / short text on this page
Customize device name · Accessories and service · Setting glow bed · Setting up energy savings · Set thermostat
Page 10 of the Faber MatriX 1050 user manual — 9 <
Page 10 · click to enlarge
Page 10

Open window detection This function is default UIT. By this on AAN to set it activates the open window detection. If the I.T.C. an unexpected rapid temperature drop within a specified time will be seen as open window or door and the device will be switched off.

To control the fireplace, the remote control must be re-connected (see section 4.1). For reconnecting the Smartphone / Tablet see section 5.1.

The I.T.C. controller records the number of hours used and standby plus energy consumption. Based on this data, the I.T.C. the maintenance period. The calculated gas consumption is a good approach. The I.T.C. also registers. the nature and number of malfunctions.

Display (set display temperature and consumption)

Here you set how the temperature and consumption are displayed. At .Accessories you can choose from:

Gas quantity in m3 Energy consumption in kWh At . .

If you are connected to your fireplace, tap the menu in the control screen on the top left. Select . . In the screen you can now choose between energy consumption or hours that the fireplace has burned. Here you can see how much m3 of gas or kWh electricity you have consumed around a day, month or year.

Here you have the possibility to measure the temperature of the I.T.C. synchronously running with your own home thermostat. You indicate at this setting how much the temperature of the I.T.C. Deviating from your own home thermostat. It is important that the remote control is in the prescribed position inside the holder. (See Chapter 8). Adjust the value only after a period of several hours has been allowed to adjust to ambient temperature.

For proper functioning of the thermostat and ECO function it is necessary to have the remote control in the holder (see fig. 1.7) to hang in a suitable place. The remote control is also the room temperature transmitter. Place the holder at an altitude of approximately 1,5m and from the radiation area of the fireplace. Avoid placement in corners, near windows, doors and heat sources such as resume radiators.

Restart/Reset function

Restart I.T.C. If your fireplace could crash due to a software failure, you can use this function the I.T.C. Restart. Watch this!

This is not possible when the fireplace is considered by I.T.C. for safety reasons. is blocked. Reset user settings Here you can return your personal settings to the factory setting.

Empty memory and disconnect all connections (remote control and Smartphone/ Tablet)

Press about 30 sec. on the controller's torque button, see Fig. 1.5 (this is located behind the control hatch). The LED changes from blue to light blue. Release the button and press the coupling button briefly again. All connections are now deleted from memory

9 <

Show 5 more labels / short text on this page
Register · Statistics · Celsius Fahrenheit · Calibration · Wall holder remote control
Page 11 of the Faber MatriX 1050 user manual — 10 <
Page 11 · click to enlarge
Page 11

10 <

Page 12 of the Faber MatriX 1050 user manual — 10 <
Page 12 · click to enlarge
Page 12
Faber MatriX 1050 — 10 < diagram (page 12)
Fig. 11
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Faber MatriX 1050

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faber MatriX 1050

Be the first to ask — other owners or our team will answer.

Original document

Faber MatriX 1050 manual PDF

12 pages·946 KB·Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…