1. MAIN INFORMATION The Manufacturer declares under his/her own responsibility that the air electrocompressors described in this manual are in compliance with the following safety rules: 98/37/EEC 72/23/EEC (modified and integrated by: 93/68/EEC) 89/336/EEC (modified and integrated by: 92/31/EEC - 93/68/EEC - 93/97/EEC) 87/404/EEC (modified and integrated by: 90/488/EEC - 93/68/EEC) in compliance with the harmonized: EN1012-1/96, EN60204-1/97, EN50081-1/92, EN50082-2/95, EN50082-2/95. 1.1 How to use this instructions manual This manual is an integral part of your compressor and shall be kept with it for future reference. Should your compressor be resold, entrust it to the new owner who will obviously need the information contained. Keep this manual in a suitable place within the operator's reach and be sure it is in a safe place protected by any agents which might damage it. Before starting the compressor, read this manual carefully so as to understand the contents clearly; consult it whenever any doubt arises. This manual contains information useful tor your safety and instructions to facilitate maintenance operations or to clarify special operations. Follow the indication contained in it and perform the recommended procedures which, if not properly observed, could result in damage to equipment or could cause personal injury. This manual does not include the spare parts list, which is available by our Authorized Resellers. Should this manual be lost, ask tor a new copy to the manufacturer. 1.2 Symbols used in this manual In order to make evident same special information, the following symbols are used: however you are not relieved trom reading the instructions manual carefully.
Warning- It refers to safety instructions to be complied with in order to ensure maximum safety conditions to the operator as well as to people in the working area, and to the compressor. Specialized personnel - Symbols indicating operations to be carried out by specialized personnel only. Machine stopped - Every operation highlighted by this symbol must only be carried out with the machine powered off. Power OFF - Before any operation the machine should be necessarily powered off. Important: symbols at the top of the page refer to the whole section.

1.3 Identification of the product The product that you purchased is marked with the EC plate. Such plate is reported on the cover of this instruction manual and on the compressor, and shows the following data: 1) Manufacturer's data 2) EC mark - year of construction 3) TYPE = name of the compressor, CODE = code of the compressor, SERlAL N. = serial number of the compressor (to be quoted when asking tor the Service Assistance) 4) compressor output air measured in (I/min) and (cfm) 5) max. operating pressure (bar and PSI) - noise of the compressor dB(A) 6) electric data: power supply (V/ph), frequency (Hz), absorbed current (A) - power (HP and kW), revolutions per minute (Rpm). 7) Possible other approvals. 1.4 Compressor description Our OILLESS series includes the compressors model Delta Star, that is compressors which do not need any lubricants to run. Such peculiarity ensures a very easy use and reduced ordinary service. Moreover, such feature allows working even on inclined plane without jeopardizing the proper operation of the machine. The range of the models includes versions with drier and soundproof cabin. The main components of your compressor are shown in the information table enclosed to this instruction manual. Such table includes the max. overall dimensions of the compressor, and the main spare and wear parts. 2. TECHNICAL FEATURES 2.1 Main features Among the most important features. the following should be noted: inner tank walls coated with rustproof paint, inner rings made of special friction-tree material, aluminium piston coated with special friction-tree material, absorption drier with cleaning automatic cycle, ergonomic guards with anti-shock handle, pressure switch / remote pressure switch with integrated starter/stop switch, non-return and safety valves, overload cutout and cooling fan, cock tor condensate drainage, single- and three-phase motors, 230 and 400 V. 2.2 Technical data See data on EC plate, according to section 1.3.


emptied. Unplug the compressor so as to prevent any sudden unexpected restart. After any maintenance operation make sure all components have been fitted correctly. Keep out children or animals from the operating area so as to prevent damages or injuries caused by any accessory connected to your compressor. Read carefully the instructions on the fitted accessory. Provide for protection against accidental contacts by automatic power cut off, taking into consideration that the compressor is of class I and is equipped with connection to the earth. 3.3 What YOU MUST NOT DO: Do not touch the cylinder heads, the cooling fins and the feed pipe. During operation, because of the high temperature achieved, those parts keep hot tor a certain time even after switching off the compressor. Do not leave inflammable, nylon objects or cloths near the compressor. Do not move the compressor with the tank under pressure. Do not use the compressor with the supply cord damaged or with precarious connection. Do not use the compressor in potential explosive environment or near free flames. Do not use the compressor in humid or dusty areas. Do not direct the air jet towards people or animais. Do not allow anybody to operate the compressor unless he/she has received correct instructions. Do not hit fans with metal or blunt objects as they could break during operation. Do not operate the compressor without air filter. Do not tamper the safety and adjusting devices. 4. INSTALLATION 4.1 Compressor unpacking and handling (Fig. 1) Make sure both the machine and all supplied accessories are perfectly safe and undammaged. When delivered, the machine is on a wooden pallet and protected by a top cardboard packing. Wear safety gloves and cut the outer straps and withdraw the cardboard from the top, then unscrew the nuts which lock the compressor.
Warning: compressors equipped with drier tend to bend because of the weight on the rear side. Balance the unit before lifting it. Compressor with 24-litre tank: size the compressor by the handles with the help of another person, then lift it. Compressor with tank over 24 litres: Lift the compressor with a fork truck of suitable capacity (see the information table), by fitting the forks through the tank supporting feet and fitting a wooden bar perpendicular so as to prevent the compressor from shifting during lifting. Fit anti-vibrating elements (Fig. 2). Packing disposal Save the packing material in case you ever need to transport the compressor in the future. We recommend that you store the packing in a safe location, at least within the

period of the guarantee. In case of need, it will be easier to send the compressor to the service centre. Afterwards, put it into the care of the company or board in charge of elimination. 4.2 Positioning As previously said all compressors can work properly even on an plane with a transversal or longitudinal inclination over 15°.
SINGLE PHASE COMPRESSORS: the compressor is equipped with a special plug (Fig.4). If necessary, contact specialized personnel for plug replacement. THREE-PHASE COMPRESSORS: it is necessary to provide the supply line with a magneto-thermal switch of suitable capacity respect to the instalfed power (Fig.4). To such purpose, follow the indications written in the table. Order number 36819 36820 36821 Compressor power (see EC plate) CV 1,5 2,5 5 (2x2,5) Absorbed power A 7,5 12 24 Direct start relay adjustment A 10 15 15+15 Power cable min. cross section mm² 2,5 2,5 4 Wall switch capacity A 16 16 32 5. ADJUSTMENTS 5.1 Timing and operation modes All compressors, apart from TANDEM modeIs can work in just one mode, i.e. the "classic" automatic mode controlled by the pressure switch/ remote pressure switch, which stops the compressor when the max. pressure is reached, and starts the compressor again when pressure decreases by 1.5 bar. For TANDEM modeIs the operation mode must be set according to the quantity of compressed air needed. We recommend that you contact your usual installer bearing

in mind the compressed air output necessary for your work, and the air output value written in the EC plate.

NOTE: Please remember to start both units together only if a big amount of compressed air is needed because under these conditions, and especially at the start-up, high electrical input peaks may occur. For the most appropriate operation cycle, contact your usual installer, taking into account your compressed air consumption and the data written on the EG label of the compressor. 6.2 Operation cycle The compressor runs completely automatically by the pressure switch, which stops the compressor when the max. pressure value is reached and restarts the compressor only when this value has decreased to the minimum value accepted.



7.4 Compressor disposal In case you need to get rid of your compressor, it is compulsory to get rid of all the parts and components according to the laws in force. In any case, contact the company or board in charge of elimination. 8. TROUBLESHOOTING Fault Cause Remedy The pressure switch valve leaks when the compressor is idle.
Make air in the tank flow out (Fig. 10), then remove the non-return valve plug and clean the seat and the seal (Fig. 12). If necessary replace the seal. The pressure switch valve leaks when the compressor is running.
Non-return valve seal defective.
Failure of empty-start valve. Replace the valve
(Fig. 5).
The compressor stops and does not start.
Cut off voltage and press the button to start (Abb. 6/6a). Contact a specialized technician. The compressor stops after reaching the max. pressure and the safety valve operates.
Overload cutout operated because of motor overheating. Winding burnt out.
Wrong operation or pressure switch broken.
Contact a specialized technician.
The compressor does not reach the set pressure and overheats too much.
Stop the compressor immediately and contact a specialized technician. The compressor is noisy with metallic clangs.
Compressor head gasket broken or valve faulty.
Bearing seizure. Stop the compressor immediately and contact a specialized technician.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The pressure switch valve leaks when the compressor is idle. | Non-return valve seal defective. | Make air in the tank flow out (Fig. 10), then remove the non-return valve plug and clean the seat and the seal (Fig. 12). If necessary replace the seal. | p.11 |
| The pressure switch valve leaks when the compressor is running. | Failure of empty-start valve. | Replace the valve (Fig. 5). | p.11 |
| The compressor stops and does not start. | Overload cutout operated because of motor overheating. Winding burnt out. | Cut off voltage and press the button to start (Abb. 6/6a). Contact a specialized technician. | p.11 |
| The compressor stops after reaching the max. pressure and the safety valve operates. | Wrong operation or pressure switch broken. | Contact a specialized technician. | p.11 |
| The compressor does not reach the set pressure and overheats too much. | Compressor head gasket broken or valve faulty. | Stop the compressor immediately and contact a specialized technician. | p.11 |
| The compressor is noisy with metallic clangs. | Bearing seizure. | Stop the compressor immediately and contact a specialized technician. | p.11 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.