Instruction/ maintenance manual of the product 500 Xantrex Technology
Go to page of 33
Xantrex Inv erter 500 Owner ’ s Guide 445-01 40-01- 01 Print ed in Chi na Web: www .xantrex.co m Email: C ustomerServic e@xantrex.com Phone: 1- 604-422-859 5 Phone: 1-800-6 70-0707 (tol l free in N .
About Xantre x Xantrex T ech nol ogy Inc. is a world- le ad ing supplier of a dva nc ed power elect roni cs a nd c ontrols with prod uct s from 50 watt mobil e unit s to 1 MW utility-scale systems for wind, solar , batteries, fuel cells, microturb ines, and backup powe r app lications in both grid-c onn ected and stand-al one systems.
.
Contents i 1. Introductio n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Important Safet y Information . . . . . . . . . . . . . . . . . . 2 Warnings and C autions . . . . . . . . . . . . . . . . . . . . . . . . 2 3. Xantrex 500 Inverter Features .
ii.
1 Introduction Thank you for purchas ing the Xant rex 500 Inverter. The 500 Inverter is part of a f amily of adv anced, high- performance po wer inverters from Xantrex, the leader in the field of high-freq uency inverter des ign.
2 2 Important Safety Information If the 500 Inverter is connected or used incorrectly , hazardous cond itions may be created . Read and save this safety information, and pay special atten tio n to all Caution and W arning statements in the guide and on the inverter itself.
3 Wa rn i ng ! Risk of f ire o r explosion. The 500 Inverter cont ains components that tend to produce arcs or sparks. T o prevent fire or explosion, do not install the inverter in compartments containing b atteries or flammable materials or in locations that require ignition - protected equipment.
4 Caution! Risk of damag e to the 500 Inverter. Reverse battery polarity (negative connected to positive; positive conn ected to negative) will damage the 500 Inverter, and it will requir e servicing. Damage caused by reverse polarity is not covered by your warr anty .
5 3 Xantrex 500 Inverter Features This section des cribes the main features o f the 500 Inverter. Figure 1 s hows the i nverter’ s AC panel. Figure 1 AC Panel on the 500 Inverter (Europe an AC Outlet) ➀ AC Outlet An AC outlet is located o n one end of the inverter .
6 When the inver ter is connected to a DC p ower source and the On/Standby switch is on, AC power is available at the outlet. ➂ Power Light The green PWR light is on all the time when the On/Standby switch is on.
7 AC Outlets Depending on your g eographic lo cation, your 50 0 Inverter will have one of the following AC outlets. Figure 2 European AC Outlet Figure 3 Briti sh AC Outlet Figure 4 Australian and New .
8 4 Connecting the 500 Inverter This secti on explains ho w to connect t he 500 Inverter. Choosing a Location For the bes t performance, choose a l ocation that i s: • Dry Do not expose the inverter to water drip or spray . • Cool Operate the inverter in a m bient temperatures between 0° C and 40° C (32 ° F and 100° F).
9 Connecting t he 500 Inverter to DC Power W a rni ng! Corros ive materials and energy hazard. T o reduce the risk o f irritation and burns , wear protective eyewear and clothing when you work with batteries. T ake special care to ensure that metal tools or personal ob jects like r ings or watch es do not contact the battery terminals.
10 Y ou can make a temporary or a permanent connection between the inverter an d the 12 volt DC power s o urce. • Use the battery clip wire assem bly to make a temporary connection ( page 1 1 ). • Hardwire the inverter to the battery to make a permanent con nection ( page 13 ).
11 Using the Battery Clip Wire A ssembly W a rni ng! Corros ive materials and energy hazard. T o reduce the risk o f irritation and burns , wear protective eyewear and clothing when you work with batteries. T ake special care to ensure that metal tools or personal ob jects like rings or watc hes do not contact the battery terminals.
12 T o connect the inverter to a 12 volt bat tery us ing t he batt ery clip wire assembly: 1. Remove the nuts from the DC terminals on the inverter . 2. Place the red rin g connector on the r ed (positive +) DC terminal, and then screw the red nut on until it is snug.
13 Hardwiring the I n verte r to the Battery A hardwired installation is illu strated in Figur e 6 . Figure 6 Hardwiring the 500 Inverter to a 12 V olt Battery T o hardwire the inverter to a 12 volt battery: 1. Cut the clips off the cable clip wire assembly .
14 2. Us ing 8.4m m 2 (8 A WG) wire or heavier, exten d the power cord if you need to, to a maximum total len gth of 2 meters (6.5 fe et ) including the existin g 500 Inverter power cord length. Solder all connections and m ake sure they are properly insulated by using electrical tape or heat shr inkable tubi ng.
15 6. Remove the nuts from the DC terminals on the inverter . 7. Place the red rin g connector on the r ed (positive +) DC terminal on the inv erter , and then s crew the red nut o n.
16 5 Operating the 500 Inverter This secti on describes normal operat ion as well as several problems th at could occur when you use the inverter . If you have a prob lem, see “T roubleshooti ng” on page 20 .
17 that occurs whe n the engine starts may trigger a low volta g e shutdo wn. • AC Overload Shutdown If you connect an AC load rated hi gher than 50 0 watts or 2.2 amps or that draws excessive sur ge power , the 500 Inverter shuts down. The PWR light stays on, and the light comes on to indicate that the inver ter is overloaded.
18 Interferenc e With Electronic Equipment Most AC products operate with the 500 Inverter as they would wi th househo ld AC power with the fo llowing exceptions. Buzzing Sou nd Some inexpe nsive stereo sys tems and “boom boxes” have inadequ ate i ntern al power su ppl y filtering and buzz slightly when powered by the 500 Inverter.
19 6 Battery Operating T ime The battery operating ti me of the 500 Inverter depends on the char ge level of the battery , battery capacity , and the amou nt of po wer dra wn by th e parti cular A C load. W ith a typical vehicle battery an d a 300 watt load, y ou can expect one or mor e hours of operating ti me.
20 7 T r oubleshooting This secti on descri bes problems you could en counter , as well as symptoms, possible causes, and various remedies. The AC load will not opera t e; red light is on. Sympt om An AC load i s plu gged in or tur ned on, operates for on e to ten se conds , and then shuts do w n.
21 Sympt om The AC load runs for more than one min ute, the alarm sounds , and the light comes o n. The inv erter is warm or hot to touch . The alarm may sound. The AC load will not operate; no inverter lights are on. Sympt om The inverter has been conn ected to the 12 vo lt battery and the b attery is char ged, but the inverter d oes not work.
22 Measured inver ter output voltage is too low . Sympt om The AC voltmeter reading is 5 to 15 volts too low . Battery operating time is less than expected. Sympt om The inverter r uns for a wh ile, and th en the light comes on. The inver ter is cool o r warm to tou ch.
23 8 W arranty Information What Does This W arranty Cover? Xantrex manufactures i ts products from parts and com ponents that are new or equivalent to new , in accordance with indu stry standard practices. This warran ty co vers an y d efects in wor kmansh ip or ma t e rials.
24 building replacement pro ducts. If Xantrex rep airs or replaces a product, it s warr anty term is not extended. Xantr ex owns all p arts remov ed from repaired pr oducts.
25 Y ou must obtain a Return Material Authorization (RMA) number fro m Xantrex bef ore return ing a product d irectly to Xantre x. Do not r eturn a produ ct to Xantrex without first obtai ning an RMA numb er .
26 T o return your 500 Inverter for out-of-warran ty service, contact Xantrex cust omer service for a R eturn Material Authorization (RMA) number , an d follow the other steps outlined in “T o Xantr ex” on page 24 . Options for payment, such as credit card o r money order , will be explained by the customer service r epresentative.
27 9 Specifications Specifications may change without notice. Electrica l AC receptacles 1 AC output voltage 230 volts AC RMS ± 5% AC output f requency 50 ± 3 Hz AC output waveform Modifi ed Sine W .
28 Physical Regulatory Dime nsion s (L x W x H) 240mm x 112m m x 66 mm (9. 5 in. x 4.4 in. x 2.6 in.) W e i ght 1.2 Kg ( 2.6 lb.) CE Mark Low V oltage Directiv e EMC Directive e Mark Automotive EMC Di.
An important point after buying a device Xantrex Technology 500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Xantrex Technology 500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Xantrex Technology 500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Xantrex Technology 500 you will learn all the available features of the product, as well as information on its operation. The information that you get Xantrex Technology 500 will certainly help you make a decision on the purchase.
If you already are a holder of Xantrex Technology 500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Xantrex Technology 500.
However, one of the most important roles played by the user manual is to help in solving problems with Xantrex Technology 500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Xantrex Technology 500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center