Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power.
XPower is a trademark of Xantrex International. Xantrex is a registered trademark of Xantrex International.
Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only.
Xpower™ Powerpack 400 and 400 Plus Owner’s Guide © April 2003 Xantrex International. All rights reserved.
UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”)
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK. Date and Revision
April 2003 Revision 2

Purpose
The purpose of this Owner’s Guide is to provide explanations and procedures for installing, operating, maintaining, and troubleshooting the XPower Powerpack 400 and XPower Powerpack 400 Plus. The Guide provides safety guidelines, detailed planning and setup information, as well as information about operating and troubleshooting the unit.
The following conventions are used in this guide.

In this guide, both the XPower Powerpack 400 and the XPower Powerpack 400 Plus (with the air compressor) are referred to as XPower Powerpack when the information applies to both models. However, when the information is specific to one model, then reference is made specifically to the XPower Powerpack 400 or to the XPower Powerpack 400 Plus.
You can find more information about Xantrex Technology Inc. as well as its products and services at www.xantrex.com
About This Guide · ii 975-0057-01-01

The XPower Powerpack 400 and XPower Powerpack 400 Plus generate a type of AC power similar to a normal household wall outlet. Operating the XPower Powerpack 400 and XPower Powerpack 400 Plus incorrectly or misusing it may damage the equipment or create hazardous conditions for the user.
The XPower Powerpack 400 and XPower Powerpack 400 Plus generates the same potentially lethal AC power as a normal household wall outlet. Do not insert foreign objects into the AC Outlet, the DC Power Socket, the Jump-Start Cable Port, or the ventilation holes. Do not expose this product to water, rain, snow, or spray.
Do not open the XPower Powerpack 400 and XPower Powerpack 400 Plus except to replace the internal battery. Have a qualified technician complete any service work.

Do not connect any AC appliance with the neutral conductor connected to ground to the XPower Powerpack 400 and XPower Powerpack 400 Plus.
Do not expose the XPower Powerpack 400 and XPower Powerpack 400 Plus to temperatures over 104 °F (40 °C).
Do not use this product where there are flammable fumes or gases, such as in the bilge of a gasoline- powered boat, or near propane tanks. Do not use this product in an enclosure containing automotive-type lead acid batteries. These batteries, unlike the sealed AGM battery in XPower Powerpack 400 and XPower Powerpack 400 Plus, vent explosive hydrogen gas which can be ignited by sparks from electrical connections.
When working on electrical equipment, always ensure someone is nearby to help you in an emergency.
iv 975-0057-01-01

Ensure at least 2" (5 cm) air space is maintained on all sides of the XPower Powerpack 400 and XPower Powerpack 400 Plus. During operation, keep away from materials that may be affected by high temperatures such as blankets, pillows and sleeping bags.
Never allow jump-start cables’ red and black clamps to touch each other or another common metal conductor. This could cause damage to the unit and/ or create a sparking/explosion hazard. Always disconnect the jump-start cables from the unit after use and clip the plastic guard over the jump-start cable port.
Jump-start cable clamps must be connected positive to positive (red clamp to battery “+”) and negative to negative (black clamp to battery “-”). A reverse polarity connection (positive to negative) may cause damage to the unit and/or create a sparking/explosion hazard.
975-0057-01-01 v

The jump-start feature is designed for short term operation only—less than 4 seconds. Operating the jump-start feature for more than 4 seconds may cause damage to the unit. Allow the XPower Powerpack 400 and XPower Powerpack 400 Plus to cool down for at least 3 minutes after each jump- start.
The battery terminals exposed at the Jump-Start Cable Port have enough energy present to cause a spark, creating an explosion hazard, or to cause burns if a metal object contacts both terminals. Always clip the plastic guard over the Port when not in use.
Do not leave the compressor unattended while operating. The compressor is designed for short term operation only. Operation of the compressor over an extended period of time will cause the compressor unit to overheat and may cause damage. Allow the compressor to cool down for 10 minutes after each 10 minutes of continuous operation.
vi 975-0057-01-01

975-0057-01-01 vii

viii 975-0057-01-01

The output of the inverter is non-sinusoidal.
975-0057-01-01 ix



Warnings and Cautions - iii Precautions When Working With Batteries- vii Precautions for Using Rechargeable Appliances - ix
About the XPower Powerpack - 1–1 Comprehensive Protection - 1–1
Automatic overload- 1–1 Overheating - 1–1 Low Battery Protection - 1–2 Jump-Start Cables Safety Feature - 1–2
Materials List - 2–1 XPower Powerpack Features - 2–2
Front Panel Detail- 2–2 Air Compressor (XPower Powerpack 400 Plus only) - 2–5 Left Side View - 2–6 Storage Compartment - 2–7 Accessories - 2–8

Operating Conditions and Guidelines - 3–1 Choosing a Location - 3–2 Using XPower Powerpack for the First Time - 3–3 Recharging with the AC Charger - 3–3 Using the light - 3–4 Operating AC Appliances - 3–4
Understanding AC Appliances - 3–4
Run Time on Typical AC Appliances - 3–5 High Surge Appliances - 3–6 Trouble Appliances - 3–6 Operating Several Appliances at Once - 3–7 Operating an AC Appliance - 3–7 Operating 12 V DC Appliances - 3–8 Jump-Starting a Vehicle’s Engine -3–10 Using the Air Compressor: XPower Powerpack 400 Plus -3–12
Over-Temperature Safety Protection -3–13 Inflating Tires -3–14 Inflating Small Sports Equipment -3–15 Connecting to an External Battery-3–17
Battery Maintenance- 4–1 Recharging the XPower Powerpack Battery - 4–2
Recharging with the AC Charger- 4–3 Recharging with the DC Charging Cable - 4–4 Recharging with a Generator’s Regulated 12 V DC Outlet 4–6 Recharging From a Solar Panel- 4–7 Replacing the Internal Battery - 4–7
Battery Life - 4–7 Obtaining a Replacement Battery - 4–8
xii 975-0057-01-01

Replacing the Battery - 4–8 Replacing the Incandescent Light -4–11 Replacing the External Fuse-4–11
Common Problems - 5–1
Buzz in Audio Equipment - 5–1 Television Interference - 5–1 Troubleshooting Reference - 5–2
Electrical Specifications - A–1 Physical Specifications - A–3
Warranty- B–2 Return Material Authorization Policy - B–5 Out of Warranty Service - B–7 Information About Your System- B–8
975-0057-01-01 xiii



About the XPower Powerpack
In addition, the XPower Powerpack 400 Plus: • Comes with a 250 psi air compressor for inflating tires and small sports equipment.
The XPower Powerpack has built-in protection against output overload. If you connect to the AC Outlet(s) an appliance that draws more than 320 W, or one which draws excessive surge power, the power to the AC Outlet automatically shuts off.
The XPower Powerpack is protected from overheating. If the inverter exceeds a safe temperature, power to the AC Outlet automatically shuts off.

Low battery protection protects the internal battery from excessive discharge and possible damage. When the AC Outlet On/Off switch is turned on, an audible alarm alerts you when the internal battery is nearly discharged (11.0 V DC) and the unit turns off at 10.5 V DC.
The XPower Powerpack comes with a user-replaceable 250 A fuse to protect the unit and vehicle battery from damage through reverse polarity and short-circuit conditions.
Introduction · 1-2 975-0057-01-01

Chapter 2 describes the main features of the XPower Powerpack. We recommend that you familiarize yourself with these features before operating the unit.
Your XPower Powerpack package includes these items: ❐ XPower Powerpack 400 or XPower Powerpack 400 Plus
❐ DC Charging Cable
The XPower Powerpack 400 Plus also includes: ❐ two nozzle adaptors for the compressor
❐ One sports needle adaptor for the compressor
If any of these materials are missing or are unsatisfactory in any way, please contact Customer Service, see Appendix B.



2 2 AC Outlets are standard 3-prong outlets supplying 120 V AC power for running an AC appliance.
3 AC Outlet ON/OFF switch illuminates when the switch is turned on.
4 Digital Display displays the inverter’s Output Power in W and Battery Charge status in % FULL.
Features · XPower Powerpack Features · 2-2 975-0057-01-01

5 Charging Status light illuminates when the XPower Powerpack is in Charging Status mode (i.e. AC Charger is connected to the inverter’s Charger Input Socket and plugged into the household 120 V AC outlet).
6 Battery Charge % light illuminates (green) when Battery Charge information is displayed on the Digital Display.
7 Output Power (W) light illuminates (green) when Output Power information is displayed on the Digital Display.
8 Display Function button, when pressed, allows for reading Battery Charge status on the Digital Display. Toggles Digital Display’s power ON/OFF.
Audible Alarm (inside the unit) sounds in the event of overheating or low battery protection on inverter.
Required Condition Required Action Note
How to...
Monitor total AC power consumed by the applications powered from the Powerpack’s 2 AC outlets
Inverter’s ON/OFF switch is turned ON; Output Power (W) light illuminates (green); AC charger is unplugged from the wall AC outlet.
No action required. The Digital Display will show the AC power drawn from the inverter by the applications powered from the Powerpack’s AC outlets.
In order to save the battery power and ensure longer inverter run time, press Display Function button to turn off the Digital Display. Press Display Function button again to turn the display On for AC power reading.

Required Condition Required Action Note
How to...
Monitor Battery Charging status
Inverter’s ON/OFF switch is turned to OFF; All appliances must be disconnected from the AC and DC power outlets; The ON/OFF switch of the incandescent light must be turned to OFF; The AC charger must be plugged into the Powerpack’s Charger Input Socket and also in to a household AC outlet.
No action required.
Recharging with the supplied AC charger is a true “plug-in-and- forget” charging method. We recommend leaving the AC charger connected when the Powerpack is not in use to permanently maintain the battery in fully charged condition.
A flashing green Charging Status light indicates that the Powerpack’s battery needs recharging and that the AC charger is charging the battery.
A steady green Charging Status light indicates that the Powerpack’s battery is fully charged and the Powerpack is ready for use.
Check Battery Charge status
Inverter’s ON/OFF switch is turned to OFF; All appliances must be disconnected from the AC and DC power outlets; The ON/OFF switch of the incandescent light must be turned to OFF; The AC charger must not be plugged into the Powerpack’s Charger Input Socket.
Push and hold the Display Function button.
This function is disabled when the AC charger is plugged in to the Charger Input Socket, or when the inverter main switch is ON. For accurate Battery Charge reading, allow 15 minutes between charging/use and battery capacity check.
The green Battery Charge (%) light will come on and the Digital Display will show the remaining battery capacity in %.
Features · 2-4 975-0057-01-01



1 On/Off switch turns the compressor unit on and off.
2 Pressure gauge shows the PSI (lb./in2)
Nozzle Adaptor Compartment is integrated into AC charger compartment.
XPower Powerpack Features · 975-0057-01-01 2-5



1 5 W incandescent light illuminates for about 30 hours when the battery is fully charged.
3 Jump-Start Cable Port supplies high power DC current. The cables connect to the Jump-Start Cable Port when jump-starting a vehicle’s battery or when connecting an external battery to the XPower Powerpack. The jump-start cable connection is designed so that the cables cannot be inserted incorrectly into the Jump-Start Cable Port.
Features · 2-6 975-0057-01-01


XPower Powerpack 400 Plus shown

1 AC Charger lets you recharge the XPower Powerpack from a standard AC wall outlet and can only be used to recharge the internal battery of the XPower Powerpack. Can be stored in AC charger compartment.
2 Charger Input Socket for use with the AC Charger supplied (see 1).
3 External Replaceable Fuse is rated at 250 A, 32 V. Located behind fuse cover.
5 AC Charger Compartment may be used for storing the AC Charger.
XPower Powerpack Features · 975-0057-01-01 2-7



2 DC Charging Cable lets you recharge the XPower Powerpack from a 12 V system in a car, SUV, RV or a boat. This can be stored in the storage compartment.
Nozzle packet (XPower Powerpack 400 Plus only) contains 2 nozzle adaptors and sports needle adaptor, in the storage compartment on the back of the unit.
Features · 2-8 975-0057-01-01

Read all operating instructions before operating the XPower Powerpack.
Do not use the XPower Powerpack to operate any AC appliances or 12 V DC appliances while recharging with the AC Charger.
The AC Charger may fail if AC appliances or 12 V DC appliances are operated while the AC Charger is connected.

The XPower Powerpack is not intended for use as a UPS (Uninterruptible Power Supply).
The XPower Powerpack contains components that tend to produce arcs or sparks. To prevent fire or explosion, do not operate the XPower Powerpack in compartments containing batteries or flammable materials, or in locations that require ignition- protected equipment.
The XPower Powerpack should be operated only in a location that meets these requirements:
:
Dry Do not allow water or other liquids to drop or splash on the XPower Powerpack.
Cool Ambient air temperature should be between 32 and 104ºF (0 and 40ºC)—the cooler the better within this range.
Leave at least 2" (5 cm) clearance around the XPower Powerpack for air flow. Ensure that the ventilation openings are not obstructed.
Do not operate the unit in the same compartment as batteries or in any compartment capable of storing flammable liquids like gasoline.
Protected from battery gases
Do not operate the unit where it will be exposed to battery gases. These gases are very corrosive, and prolonged exposure will damage the XPower Powerpack.

Using XPower Powerpack for the First Time
Recharging with the AC Charger is a true “plug-in-and- forget” charging method. We recommend leaving the AC Charger connected when the XPower Powerpack is not in use. To recharge with the AC Charger:
The green Charging Status light changes from flashing to steady when charging is complete (about 35 hours if the battery is completely discharged).
n · 975-0057-01-01 3-3

Important: The 35 hour charging time for the XPower Powerpack assumes that there is 120 V at the AC wall outlet. If the voltage is less than 120 V AC, it may take more than 35 hours to fully recharge the XPower Powerpack. If, after 35 hours of charging, the green Charging Status light is still flashing, continue to charge the unit for another 15 hours.
The XPower Powerpack has a built in incandescent light which will operate for about 30 hours before the unit needs to be recharged. The ON/OFF switch is located beneath the light. The light can be adjusted up and down by pushing against the top or bottom of the rim around the lens.
AC appliances are rated by how much electrical power (in watts) they consume. XPower Powerpack can power most appliances within its continuous power rating (320 W, 2.7 A).
Operation · 3-4 975-0057-01-01

Some appliances may be difficult or impossible to operate from the XPower Powerpack. They may have high surge requirements or should not be run from the XPower Powerpack. See “High Surge Appliances” on page 3–6 and “Trouble Appliances” on page 3–6.
Typical AC appliances that can be used on the XPower Powerpack are listed in Table 3-1.
Table 3-1 AC Appliances and Run Times
AC Appliance Wattsa
Cordless telephone (stand by) 5 40
Home security system 5 40
Clock radio 8 22
Portable stereo 10 17
Fluorescent work light 14 10
Fireplace fan 20 8
Laptop computer 25 6
Table lamp 40 3
Color TV – 13" 60 2 h 30 min.
3/8 “ drill 190 20 min.
a. Represents actual power consumption as measured on sample appliances.
b. Operating times assume a fully charged 20 Ah battery and may vary based on model/brand of appliance.
Operating AC Appliances · Hoursb · 975-0057-01-01 3-5

The wattage rating of AC appliances is the average power used by the appliance. Appliances such as televisions, computer monitors and appliances with motors consume much more power than their average rating when they are first switched on. Although XPower Powerpack can supply momentary surge power up to 600 W, some appliances may exceed the capabilities of the XPower Powerpack and trigger the inverter’s safety overload shutdown circuit.
CAUTION
The output of the Powerpack’s inverter is non- sinusoidal. Some equipment may be damaged by the inverter’s modified sine wave output (non-sinusoidal).
Operation · t · 3-6 975-0057-01-01

You can run several AC appliances if the total rating of all the appliances (in watts) does not exceed 320 W. You can run appliances using an AC power bar. Run time, however, will decrease accordingly with the number of appliances being operated and the AC power being consumed.
Before operating your AC appliance, ensure that the battery of the XPower Powerpack is fully charged. See “Recharging with the AC Charger” on page 3–3 for details. To operate an AC appliance:
The switch illuminates to indicate AC power is available at the AC Outlets.
When using the XPower Powerpack to operate an AC appliance and the low battery warning sounds, the warning gives you time to shut your AC appliance off before loss of AC power. If you ignore the warning, the XPower Powerpack automatically turns off a few minutes later to prevent battery damage. In the event of an overload, low battery voltage or overheating, the XPower Powerpack automatically shuts down.
Operating AC Appliances · 975-0057-01-01 3-7

The XPower Powerpack can operate 12 V DC auto, RV, marine, or other portable appliances that draw 12 A or less from a 12 V DC power outlet or from a vehicle’s lighter socket.
The DC Power Socket does not automatically switch off when the internal battery is discharged. To protect the internal battery against damage resulting from total discharge, We recommend that the AC Outlet On/Off switch is turned On when using the XPower Powerpack to operate a 12 V DC appliance.
Having the AC Outlet On/Off switch turned On enables the alarm to warn you when the 12 V DC appliance has nearly depleted the internal battery.
Operation · 3-8 975-0057-01-01

Operating 12 V DC Appliances
Typical 12 V DC appliances that can be used on the XPower Powerpack are listed in Table 3-2.
Table 3-2 12 V DC Appliances and Run Times
12 V DC Appliance Wattsa
5 W incandescent light (built into the unit)
Stereo/CD player 10 17
Portable Cooler 30 4
a. Represents actual power consumption as measured on sample appliances.
b. Operating times assume a fully charged 20 Ah battery and may vary based on model or brand of appliance.
c. Represents talks time available from 10 recharge cycles.
To operate a 12 V DC appliance:
If the 12 V DC appliance draws more than 12 A (or has a short-circuit defect), the internal circuit breaker of the XPower Powerpack shuts off the power to the 12 V DC appliance. If this occurs, unplug the 12 V DC appliance, and the internal circuit breaker automatically resets after a few seconds.
As the DC power socket is internally wired directly to the internal battery, extended operation of a 12 V DC appliance may result in excessive battery discharge. See Caution for “Equipment damage” on page 3–8.
Hoursb · Cellular telephonec · 975-0057-01-01 3-9

You can use the XPower Powerpack to jump-start a vehicle or boat engine that has a 12 V starting battery using the supplied Jump-Start Cables.
Never allow cables’ red and black clamps to touch each other or another common metal conductor. This could cause damage to the unit and/or create a sparking/explosion hazard. Always disconnect the clamps for the unit after use and clip the plastic guard over the jump-start cable port.
Jump-start cable clamps’ connection to the vehicle’s battery terminals must be positive to positive (red clamp to battery “+”) and negative to negative (black clamp to battery “-”). A reverse polarity connection (positive to negative) may cause damage to the unit and/or create a sparking/ explosion hazard.
The battery terminals exposed at the Jump-Start Cable Port have enough energy present to cause a spark, creating an explosion hazard, or to cause burns if a metal object contacts both terminals. Always clip the plastic guard over the Port when not in use.
Operation · 3-10 975-0057-01-01

Jump-Starting a Vehicle’s Engine
To jump-start a vehicle or boat engine:
The battery’s positive terminal is usually larger in diameter than the negative terminal. In most vehicles, the battery’s positive terminal has a red wire connected to it.
Before starting the engine, make sure the XPower Powerpack and the cables are clear of belts and fans. Do not crank the engine for more than 4 seconds.
975-0057-01-01 3-11

The jump-start feature is designed for short term operation only—less than 4 seconds. Operating the jump-start feature for more than 4 seconds may cause damage to the unit. Allow the XPower Powerpack to cool down for at least 3 minutes after each jump-start.
The compressor is designed for short term operation only.
Operating the compressor over an extended period of time will cause the compressor unit to overheat which could lead to fire. Allow the compressor to cool down for 10 minutes after each 10 minutes of continuous operation.
Operation · 3-12 975-0057-01-01

Do not leave the compressor unattended while in operation. Keep out of reach of children.
Never leave the compressor unattended while in operation. The compressor is capable of inflating to 250 PSI. Do not exceed the recommended pressure of either the compressor or the object being inflated. If either recommended pressure is exceeded, an explosion may result.
It is recommended that you follow the warnings and turn the compressor off for 10 minutes after every 10 minutes of operation. However, the XPower Powerpack 400 Plus is equipped with an over-temperature safety protection feature that automatically turns the compressor off if it begins to overheat. Once the compressor cools down to its normal operating temperature it will automatically turn on again and continue inflating. You should turn the compressor off at the power switch if this safety feature engages, and allow the compressor to cool for 15 minutes before re-starting.
975-0057-01-01 3-13

Never leave the compressor unattended once it has switched itself off due to overheating. It will turn on again and continue inflating when its internal temperature drops.
Turn the compressor off at the power switch after each use or any time the compressor turns off automatically.
Table 3-3 Pressure Specifications for Common Items
Tires PSI Other Inflatables PSI
520-13 26 Football 13
A-78-14 26 Basketball 9
E78-14 30 Volleyball 5
H-78-14 24 Lawn Tractor Tire 22

If the pressure gauge on the compressor indicates more than twice the recommended pressure for the object you are inflating, and you have only started to inflate the object, the valve connector is incorrectly connected to the valve stem. This may damage the XPower Powerpack 400 Plus. Remove and reattach the valve connector to the valve stem.
To inflate your vehicle, motorcycle, or bicycle tires:
You can use the compressor to inflate small sports equipment such as balls (soccer balls and footballs).
975-0057-01-01 3-15

The XPower Powerpack cannot be used to inflate large capacity inflatables such as float tubes, large air mattresses, and inflatable boats. These types of products require extended inflating times which may damage the compressor.
To inflate small sports equipment:
OR If necessary, use a supplied nozzle adaptor.
Allow the compressor to cool down for 10 minutes after each 10 minutes of continuous operation.
Operation · 3-16 975-0057-01-01

Connecting to an External Battery
You can extend battery operating times by connecting the XPower Powerpack to a larger external battery. For example, an external 60 Ah battery gives approximately four times the operating time of the XPower Powerpack internal 20 Ah battery.
Never allow jump-start cables’ red and black clamps to touch each other or another common metal conductor. This could cause damage to the unit and/or create a sparking/explosion hazard. Always disconnect the jump-start cables from the unit after use and clip the plastic guard over the jump-start cable port.
Jump-start cable clamps must be connected positive to positive (red clamp to battery “+”) and negative to negative (black clamp to battery “-”). A reverse polarity connection (positive to negative) may cause damage to the unit and/or create a sparking/explosion hazard.
975-0057-01-01 3-17

Use a sealed, non-spillable battery for indoor use. Common auto and marine batteries are not suitable for indoor use unless their fumes are vented outdoors. Common auto and marine batteries contain acid, which is hazardous if spilled. Wear eye protection and protective clothing when connecting the XPower Powerpack to an external battery.
To connect the XPower Powerpack to an external battery using the jump-start cables:
Do not remove the cables from the Jump-Start Cable Port when the positive and negative clamps are connected to the terminals of the external battery.
To disconnect the cables from an external battery and from the XPower Powerpack:
Operation · 3-18 975-0057-01-01

Connecting to an External Battery
Do not recharge the XPower Powerpack when an external battery is connected. The AC charger may be damaged.
975-0057-01-01 3-19



Chapter 4 provides information on maintaining your internal battery, recharging options for the internal battery, and replacing user-replaceable parts. Routine maintenance is required to keep your XPower Powerpack operating properly. Occasionally clean the exterior of the unit with a damp cloth to remove the accumulated dust and dirt.
Disconnect all sources of AC power and DC power before performing any type of maintenance.
All rechargeable batteries gradually discharge when left standing, and you need to recharge them periodically to maintain maximum battery capacity. The AC Charger supplied with the XPower Powerpack is designed to regulate the charging process, ensuring that the battery is always fully charged but never overcharged. To ensure safe recharging and maximum battery life, recharge the XPower Powerpack only with the supplied charger or approved battery chargers.

s.
Due to inherent self-discharge, lead acid batteries must be charged at least every 3 months, especially in a warm environment. Leaving a battery in a discharged state, or not recharging every 3 months, may result in permanent battery damage and poor jump-start performance.
Do not attempt to recharge the XPower Powerpack battery if it is frozen. Gradually warm the frozen battery to 32 °F (0 °C) before recharging.
To check the battery’s charge level, press the Display Function button.
Maintenance · 4-2 975-0057-01-01

Recharging the XPower Powerpack Battery
Recharging with the AC Charger is a true “plug-in-and- forget” charging method.
Do not operate AC or DC appliances while the XPower Powerpack is being recharged with the AC Charger.
The AC Charger may be permanently damaged if AC appliances or 12 V DC appliances are operated while the AC Charger is connected.
To recharge with the AC Charger:
Important: The 35-hour charging time for the XPower Powerpack assumes that there is 120 V at the AC wall outlet. If the voltage is less than 120 V AC, it may take more than 35 hours to fully recharge the XPower Powerpack. If, after 35 hours of charging, the green Charging Status light is still flashing and not steady, continue to charge the unit for another 15 hours.
975-0057-01-01 4-3

Once the battery is fully charged, the charging voltage and current automatically reduces to a maintenance level and the XPower Powerpack may be left permanently connected to the AC Charger. If your utility power is interrupted, the charging process automatically restarts when power returns.
Using the DC Charging Cable, the XPower Powerpack can be recharged while you drive your vehicle.
Do not use this recharging method if your vehicle has abnormally high voltage electrical systems that operate above 15 V DC. This may lead to accumulations of hydrogen, causing exposure to fire and explosion hazard.
Do not operate AC or DC appliances while the XPower Powerpack is being recharged with the DC Charging Cable from your vehicle.
Maintenance · 4-4 975-0057-01-01

Recharging the XPower Powerpack Battery
To recharge the XPower Powerpack while you drive using the DC Charging Cable:
Most of the XPower Powerpack’s capacity will be restored in four hours while the vehicle engine is running.
975-0057-01-01 4-5

WARNING: Fire and Explosion Hazard
The generator output must be intended for battery charging and have an output of 15 V or less. An unregulated output or one that exceeds 15 V DC can damage the battery.
This may lead to accumulations of hydrogen, causing exposure to fire and explosion hazard.
Most of the XPower Powerpack’s battery capacity will be recharged in a few hours.
Maintenance · 4-6 975-0057-01-01

Replacing the Internal Battery
Small, unregulated 12 V solar panels rated to produce a maximum of 2.5 A (or 30 W) can be used to charge the XPower Powerpack through the Charger Input Socket. You will need to purchase a standard 5.5 mm OD x 2.5 mm (0.217” x 0.10”) ID DC Coaxial (barrel type) connector to mate with the Charger Input Socket. To recharge with a solar panel:
Once the connector is inserted into the Charger Input Socket and the solar panel is placed in the sun, the XPower Powerpack charges automatically just as with the AC Charger. See “Recharging with the AC Charger” on page 4–3. It takes about ten hours in direct sunlight to recharge the XPower Powerpack from a 2.5 A solar panel.
The high quality battery used in the XPower Powerpack will serve as a reliable power source for years when properly maintained. To maximize battery life, it is important to recharge the XPower Powerpack battery after each use.
975-0057-01-01 4-7

Discharging the internal battery below 10.0 V will damage the battery and shorten its life.
Replacement batteries are available from stores that specialize in and have a selection of lead acid, AGM (Absorbed Glass Mat) batteries. Refer to Table 4-1 for a listing of batteries approved for use with the XPower Powerpack:
Table 4-1 Approved Replacement Batteries
Replacement Battery Where to Buy
Panasonic #LC–X1220P (12 V 20 Ah)
EnerSys #NPX–80 (12 V 20 Ah)
WARNING: Shock or Electrical Hazard
Read this entire section before disassembling the unit.
Maintenance · 4-8 975-0057-01-01

Replacing the Internal Battery
If you do not know how to safely remove and install batteries, have this task performed by a qualified service technician.
When installing the replacement battery, make sure the battery polarity is correct. Reverse polarity will damage the XPower Powerpack and could cause serious injury.
To replace the battery:
975-0057-01-01 4-9


Make sure the positive battery terminal is next to the red positive (+) internal cable and the black negative terminal is next to the black negative (–) internal cable.
Maintenance · Fasteners · 4-10 975-0057-01-01

Replacing the Incandescent Light
To replace a light bulb: 1. Turn the light switch off.
The replacement fuse must be rated at 250 A, 32 V DC. See page 2–7 for a diagram. To replace the external fuse: 1. Remove the fuse cover.
975-0057-01-01 4-11



Troubleshooting will help you identify the common problems than can occur with the XPower Powerpack. Read this chapter before calling Customer Service. If you cannot solve the problem with the XPower Powerpack, record the information asked for on “Information About Your System” on page B–8 and then call Customer Service at 1-800-670-0707.
Some inexpensive stereo systems have inadequate internal power-supply filtering and may buzz slightly when powered by the XPower Powerpack. The best solution to eliminate the buzzing is to use an audio system with a good quality filter.

Do not remove the cover of the XPower Powerpack or disassemble the XPower Powerpack except to replace the internal battery or 250 A fuse. The XPower Powerpack does not contain any internal user-serviceable parts and attempting to service the unit yourself could result in electrical shock or burn.
Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
AC appliance will not operate; audible alarm is not sounding.
AC appliance rated more than 320 W, the safety overload has tripped.
Use an AC appliance with a power rating less than 320 W.
AC appliance is rated less than 320 W, high starting surge has tripped the safety overload.
AC appliance may exceed the XPower Powerpack’s surge capability. Use an AC appliance with a starting surge within the XPower Powerpack surge rating.
Appliance power requirements exceed the capability of the XPower Powerpack.
Unplug the appliance and confirm that the appliance’s power requirement is 320 W or less before attempting to restart the appliance.
Troubleshooting · Overload shutdown · 5-2 975-0057-01-01

Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
AC appliance will not operate; audible alarm is sounding.
Battery has discharged to 10.5 V.
Turn the AC Outlet On/Off switch off and recharge the XPower Powerpack.
Inverter has overheated due to poor ventilation or excessively warm environmental conditions.
Turn the AC Outlet On/Off switch off and allow the XPower Powerpack to cool for 15 minutes or more. Clear blocked fan opening or remove objects covering the unit, then restart the XPower Powerpack. Move to a cooler environment.
Inverter has overheated due to poor ventilation or excessively warm environmental conditions.
Turn off the AC Outlet On/Off switch, and let the XPower Powerpack cool down.
Alarm sounds Internal battery is nearly discharged. (11.0 V). If you ignore this warning, the XPower Powerpack automatically switches off when the battery reaches 10.5 V.
Turn the AC outlet ON/OFF switch OFF and recharge the XPower Powerpack.
Run time is less than expected.
Internal battery is not fully charged.
Recharge using the AC Charger, until green Charging Status light is steady.
AC appliance power consumption is higher than expected.
Check AC appliance power or wattage rating (or current draw for 12 V DC appliances) and compare with Table 3-1 on page 3–5 and Table 3-2 on page 3–9.
Troubleshooting Reference · Over- temperature shutdown · 975-0057-01-01 5-3

Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
Measured AC output voltage is too low.
Use of an average-reading, AC voltmeter to read output voltage.
The modified sinewave (MSW) output of the XPower Powerpack requires a true RMS reading meter, such as the Fluke 87 series, for accurate measurement.
Battery is almost fully discharged.
Press Display Function button to verify battery status and recharge the XPower Powerpack as necessary. “Battery Charge %” reading on the digital display is only accurate when the XPower Powerpack has been disconnected from all appliances and all charging sources for fifteen minutes.
Charging Status light is Off when AC Charger is connected
No AC power at the AC wall outlet.
Ensure power is available at the AC wall outlet.
AC Charger is faulty.
Replace the AC Charger.
Green Charging Status light is flashing (indicating recharging) and Battery Charge (%) does not turn on.
Battery Charge (%) reading on digital display is only accurate when the XPower Powerpack has been disconnected from all appliances and all charging sources for fifteen minutes.
Unplug the charging sources and any appliances and let the XPower Powerpack rest for 15 minutes to obtain an accurate reading.
Troubleshooting · 5-4 975-0057-01-01

Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
Green Charging Status light is still flashing and hasn’t changed to steady after 50 hours of charging.
The voltage at the AC wall outlet is less than 120 V AC.
Use AC wall outlet that supplies 120 V AC.
Internal battery is permanently damaged.
Replace the battery.
The compressor runs but won’t inflate (XPower Powerpack 400 Plus only).
The valve connector may not be securely placed on the valve stem.
Check that the valve connector is securely placed on the valve stem before closing the thumb latch.
The item being inflated may have a leak.
Check that the item being inflated has no leaks.
Check the compressor hose for any breaks or leaks at connections.
The compressor runs slowly (XPower Powerpack 400 Plus only).
The compressor may have overheated from excessive use.
Turn off the compressor and let it cool down.
Battery voltage is too low.
Check the condition of the internal battery. The battery may need to be recharged or replaced.
Troubleshooting Reference · 975-0057-01-01 5-5

Table 5-1 Troubleshooting reference
Problem Possible Cause Solution
The engine being jump- started will not start.
XPower Powerpack battery is not fully charged.
Recharge the XPower Powerpack battery.
The engine condition is poor.
Have the engine serviced.
External fuse (250 A) is blown.
Replace 250 A, 32 V fuse with same type and ratings.
The engine start capacity exceeds the XPower Powerpack jump-start capability.
The battery clamps of the jump-start cables measure zero volts.
External fuse (250 A) is blown.
Replace 250 A, 32 V fuse with same type and ratings.
The light does not turn on.
Light bulb has burnt out.
Remove lens cover and replace bulb with one of the same type and rating.
Troubleshooting · 5-6 975-0057-01-01

Electrical Specifications
12 V DC Section
Internal battery type sealed, AGM (Absorbed Glass Mat) lead acid
Internal battery voltage (nominal) 12 V DC
Internal battery capacity (minimum) 20 Ah
Internal battery CCA rating 200 CCA
DC Power Socket (maximum continuous load) 12 A with automatic reset
Built-in incandescent light (replaceable) 5 W bulb
Jump-start cable port 50 A
Jump-start fuse (external - user replaceable) 250 A
\

Output voltage 115 ± 10 V AC RMS
Output frequency 60 Hz ± 4 Hz
Output wave form modified sinewave
No load current draw
Input voltage range 10.5 to 15.0 V DC
Low battery alarm 11.0 V DC
Low battery shutdown 10.5 V DC
High battery voltage shutdown Yes, automatic reset
Over temperature shutdown Yes, automatic reset
Overload shutdown Yes, automatic reset
AC output short circuit protection Yes, automatic reset
Fuse (internal) 2 x 25 A or 1 x 50 A
Operating temperature range 32 – 104 ºF (0 – 40 ºC)
Storage temperature range 32 – 86ºF (0 – 30 ºC)
Internal Battery Charging Controller System
AC Charger bulk charging current 750 mA
Peak charging voltage (nominal) 14.2 V
Charge restart voltage (nominal) 12.9 V
Float charge after full charge is completed (nominal)
AC Charger input socket maximum current 2.5 A
Specifications · AC Power Section · 1 mA

Air Compressor (XPower Powerpack 400 Plus only)
Pressure 250 PSI (lb./in2)
Jump-start cables 24" (0.61 m), 4 AWG wire with black and red battery clamps
DC charge cable 39" (1 m) 18 AWG with male to male lighter plugs
AC Charger input 120 ± 10 V AC, 60 Hz
Nozzle adaptor (for air compressor on the XPower Powerpack 400 Plus only)
one sports needle adaptor
XPower Powerpack 400 XPower Powerpack 400 Plus
Depth 8" (20.3 cm) 8" (20.3 cm)
Width 16" (40.6 cm) 16" (40.8 cm)
Height 9 ½" (24.1 cm) 9 ½" (24.1 cm)
Weight 21.8 lb. (9.9 kg) 23 lb. (10.5 kg)


Information
Appendix B contains the warranty for your XPower Powerpack 400 and XPower Powerpack 400 Plus as well as instructions for returning the product for servicing. Appendix B also has a form where you can record information, “Information About Your System” on page B–8, in case you need to contact Customer Service.

What does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc. ("Xantrex") and covers defects in workmanship and materials in your XPower Powerpack 400 and XPower Powerpack 400 Plus. This warranty lasts for a Warranty Period of 6 months from the date of purchase at point of sale to you, the original end user customer. This Limited Warranty is transferable to subsequent owners but only for the unexpired portion of the Warranty Period. What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided that you notify Xantrex of the product defect within the Warranty Period, and provided that Xantrex through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty. Xantrex will, at its option, use new and/or reconditioned parts in performing warranty repair and building replacement products. Xantrex reserves the right to use parts or products of original or improved design in the repair or replacement. If Xantrex repairs or replaces a product, its warranty continues for the remaining portion of the original Warranty Period or 90 days from the date of the return shipment to the customer, whichever is greater. All replaced products and all parts removed from repaired products become the property of Xantrex. Xantrex covers both parts and labor necessary to repair the product, and return shipment to the customer via a Xantrex-selected non- expedited surface freight within the contiguous United States and Canada. Alaska and Hawaii are excluded. Contact Xantrex Customer Service for details on freight policy for return shipments outside of the contiguous United States and Canada. How do you get service? If your product requires troubleshooting or warranty service, contact your merchant. If you are unable to contact your merchant, or the merchant is unable to provide service, contact Xantrex directly at:
Phone:1-800-670-0707 (toll free) 1-604-422-2777 (direct) Fax:1-604-420-2145 Email:CustomerService@xantrex.com


THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER'S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY.
IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND, ANY LOSS OR DAMAGE TO PROPERTY, ANY PERSONAL INJURY, ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE, OR THE INCORRECT INSTALLATION, INTEGRATION OR OPERATION OF THE PRODUCT.
If this product is a consumer product, federal law does not allow an exclusion of implied warranties. To the extent you are entitled to implied warranties under federal law, to the extent permitted by applicable law they are limited to the duration of this Limited Warranty. Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages, so the above limitation(s) or exclusion(s) may not apply to you. This Limited Warranty gives you specific legal rights. You may have other rights which may vary from state to state or province to province.

Please refer to your product manual for limitations on uses of the product. SPECIFICALLY, PLEASE NOTE THAT THE XPower Powerpack 400 and XPower Powerpack 400 Plus SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, XANTREX MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE USE OF THE XANTREX XPower Powerpack 400 and XPower Powerpack 400 Plus IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. Please note that the XPower Powerpack 400 and XPower Powerpack 400 Plus is not intended for use as an uninterruptible power supply and Xantrex makes no warranty or representation in connection with any use of the product for such purposes.

If you are returning a product from outside of the USA or Canada In addition to the above, you MUST include return freight funds and are fully responsible for all documents, duties, tariffs, and deposits. If you are returning a product to a Xantrex Authorized Service Center (ASC) A Xantrex return material authorization (RMA) number is not required. However, you must contact the ASC prior to returning the product or presenting the unit to verify any return procedures that may apply to that particular facility.

If the warranty period for your XPower Powerpack 400 and XPower Powerpack 400 Plus has expired, if the unit was damaged by misuse or incorrect installation, if other conditions of the warranty have not been met, or if no dated proof of purchase is available, your inverter may be serviced or replaced for a flat fee. To return your XPower Powerpack 400 and XPower Powerpack 400 Plus for out of warranty service, contact Xantrex Customer Service for a Return Material Authorization (RMA) number and follow the other steps outlined in “Return Procedure” on page B–6. Payment options such as credit card or money order will be explained by the Customer Service Representative. In cases where the minimum flat fee does not apply, as with incomplete units or units with excessive damage, an additional fee will be charged. If applicable, you will be contacted by Customer Service once your unit has been received.

Warranty and Product Information
As soon as you open your XPower Powerpack 400 and XPower Powerpack 400 Plus package, record the following information and be sure to keep your proof of purchase.
❐ Serial Number (on DC end)
❐ Purchased From
❐ Purchase Date
If you need to contact Customer Service, please record the following details before calling. This information will help our representatives give you better service.
❐ Type of installation [e.g. RV, truck, vehicle, home]
❐ Warning, Error or Panel Fault Message
❐ Appliances operating when problem occurred
❐ Description of problem
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.